LI50 CCD Scanner Specifications
Model
Description
Interface
LI50
CCD Scanner - Undecoded
Decoder Required P22, R22, T54, T701, T802
Operational
Light Source
Scan Speed
660 nm LED
50 scans/sec Unidirectional
Scan Angle
4.7” (120mm) maximum scan width
Minimum Bar Width
Print Contrast
4 mil
0.90
Indicators (LED)
Special Operation
System Interface
Bi-Color LED
5.9”
Hands Free Stand Support (Optional Stand)
TTL - RJ45 Worth Data Decoder Interface
Decoder Compatibility
P22, R22, T54, T701, T802
Physical
Height
Depth
Width
Weight
Cable
5.9” (150mm)
4.6” (117mm)
2.6” (66mm)
6 oz - 170g
C39 Coiled Cord 2’-5’ (610mm-1525mm)
2.6”
Power
Input Voltage
Power (nominal)
EMC
5VDC 10%
Undecoded: <1mA Idle, 190mA scanning
FCC part 15 class A
EN 55024, 61000-3-2, 61000-3-3 CE Compliant
4.6”
Environmental
Operating Temperature
Storage Temperature
Humidity
14ºF to 122ºF (0ºC to 50ºC)
-4ºF to 140ºF (-20ºC to 60ºC)
5% to 95% non-condensing
6' drop to concrete
The LI50 CCD requires one of the
following decoders:
Shock
Warranty
2 Years - Parts & Labor
P22 USB/
Keyboard Decoder
R22 RS-232
Serial Decoder
T54
TriCoder
T701
RF Terminal
T802
RF Terminal
Scan Range for LI50 Long Range CCD Scanner
10”
0”
30”
20”
40”
4”
7”
12”
2”
6 mil narrow bar width
10 mil narrow bar width
40 mil narrow bar width
Worth Data Inc. USA
623 Swift St.
Santa Cruz, CA 95060
tel. 800-345-4220
fax. 831-458-9964
Worth Data Inc. Europe
21-23 Fenian Street
Dublin 2, Ireland
tel. 353 1 6614 566
fax. 353 1 6614 622
email. [email protected]
MADE IN TAIWAN