Wolf Appliance Company Range R606CG User Manual

Planning Information  
60" (1524) Gas Ranges  
M O D E L S R 6 0 6 C G , R 6 0 6 D G A N D R 6 0 6 F  
Location of  
rating plate  
French top  
(optional)  
5" (127) riser  
(optional)  
Porcelain-coated  
cast iron top grates  
Dual brass  
burners  
Model R606CG  
Model R606DG  
Model R606F  
Burner drip pan  
Oven light / convec-  
tion fan switches  
Pull-out drip tray  
Oven indicator  
light  
Large red  
control knobs  
Full side panels  
and skirt  
Spring/damper  
door system  
Stainless steel  
exterior finish  
Three adjustable  
racks per oven  
Large-capacity  
convection ovens  
Model R604CF shown with optional 5" (127) riser.  
If it looks as if it could be in a restaurant kitchen, well,  
that’s natural. That’s precisely where Wolf has spent the  
past seven decades, perfecting the form, function and  
sheer durability of our stainless steel gas ranges.  
The Wolf 60" (1524) gas range is  
available in natural or LP gas, with your  
choice of three top configurations.  
Model numbers indicate the features;  
(C) charbroiler, (G) griddle, (DG) double  
griddle and (F) French top. The model  
number followed by (-LP) denotes an LP  
gas model.  
Wolf gas ranges offer a variety of standard features  
such as an infrared oven broiler, convection baking, dual  
brass surface burners and our signature large red control  
knobs. Optional infrared charbroiler, infrared griddle and  
French top give you the freedom to customize your gas  
range.  
This appliance is certified by Star-K  
to meet strict religious regulations in  
conjunction with specific instructions  
Let Wolf, the corporate companion and kitchen soul  
mate of Sub-Zero, fuel your passion for cooking and  
kitchen design.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
1
9/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
60" (1524) Gas Ranges  
M O D E L S R 6 0 6 C G , R 6 0 6 D G A N D R 6 0 6 F  
M O D E L O P T I O N S  
S P E C I F I C A T I O N S  
Six Burners/Charbroiler  
and Griddle  
Overall Range Width  
60" (1524)  
R606CG  
Overall Range Height  
(to cooking surface)  
Six Burners/Double  
Griddle  
37" (940)  
R606DG  
R606F  
Overall Range Depth  
283/8" (721)  
Six Burners/French Top  
Surface Burners  
Natural gas models listed, for LP gas add  
(-LP) to the model number.  
16,000 Btu/hr (4.7 kW) burners with 500 Btu/hr  
(.1 kW) delivered at simmer  
Infrared Charbroiler  
16,000 Btu/hr (4.7 kW)  
V E N T I L A T I O N O P T I O N S  
Infrared Griddle  
18,000 Btu/hr (5.3 kW)  
18,000 Btu/hr (5.3 kW)  
15,000 Btu/hr (4.4 kW)  
30,000 Btu/hr (8.8 kW)  
18,000 Btu/hr (5.3 kW)  
60" (1524) Pro wall hood or liner  
Double Griddle (two burners)  
French Top  
66" (1676) Pro wall or island  
hood or liner  
Also refer to the Pro Ventilation section of  
our website, wolfappliance.com.  
Oven Burner – Bake (per oven)  
Infrared Oven Broiler (per oven)  
A C C E S S O R I E S  
Overall Oven Interior Capacity (per oven) 4.4 cu ft (125 L)  
5" (127) and 10" (254) classic  
stainless steel risers  
Overall Interior Dimensions  
(per oven)  
24"W x 185/8"H x 17"D  
(610 x 473 x 432)  
20" (508) classic stainless steel  
riser with shelf  
Usable Interior Dimensions  
(per oven)  
24"W x 161/2"H x 17"D  
(610 x 419 x 432)  
Classic stainless steel island trim  
Black control knobs  
Opening Width  
601/4" (1530)  
Electrical Supply Requirements  
110/120 V AC  
Porcelain-coated, cast iron wok  
grate  
50/60 Hz, 15 amp circuit  
Power Cord  
6' (1.8 m) power cord  
with grounded plug  
Porcelain-coated, cast iron two-  
burner S-grates  
Shipping Weight  
875 lbs (397 kg) – 950 lbs (431 kg)  
Oven rack  
Specifications are subject to change without notice.  
Hardwood cutting board—griddle  
models only  
IMPORTANT NOTE: A minimum 5" (127) riser is required when  
installing a gas range against a combustible surface. A minimum  
10" (254) riser is required when installing a gas range with a char-  
broiler or griddle against a combustible surface.  
High altitude conversion kit  
Accessories are available through your  
Wolf dealer. To obtain local dealer  
information, visit the Showroom Locator  
section of our website, wolfappliance.com.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
60" (1524) Gas Ranges  
M O D E L S R 6 0 6 C G , R 6 0 6 D G A N D R 6 0 6 F  
I N S T A L L A T I O N S P E C I F I C A T I O N S  
VENTILATION HOOD  
44"min (1118)  
COUNTERTOP  
TO COMBUSTIBLE  
MATERIALS  
30"(762) TO 36"(914)  
COUNTERTOP  
TO BOTTOM OF  
13" max  
(330)  
18"min (457)  
TO COUNTERTOP  
6"min (152)  
TO  
VENTILATION HOOD  
COMBUSTIBLE  
MATERIALS  
(BOTH SIDES)  
1
60 /4 (1530)  
"
FINISHED ROUGH OPENING WIDTH  
36"  
(914)  
37"  
10"  
12"  
(940) TO  
COOKING  
SURFACE  
(254)  
(305)  
8"  
E
2"  
(203)  
(51)  
1
5 /2  
"
(140)  
G
12"  
5"  
3"  
(305)  
(127)  
LOCATION OF GAS SUPPLY EXTENDS  
3" (76) ON FLOOR FROM BACK WALL  
(76)  
ISLAND INSTALLATIONS: 12" (305) MINIMUM CLEARANCE FROM BACK  
OF RANGE TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP –  
0" (0) TO NON-COMBUSTIBLE MATERIALS  
D I M E N S I O N S  
Overall Width of Range  
Finished Rough Opening Width  
Location of Gas Supply  
Location of Electrical  
60" (1524)  
601/4" (1530)  
Within shaded area  
Within shaded area  
See Installation Instructions shipped with unit for detailed specifications.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
60" (1524) Gas Ranges  
M O D E L S R 6 0 6 C G , R 6 0 6 D G A N D R 6 0 6 F  
I N S T A L L A T I O N N O T E S  
Refer to the illustrations and specifications  
for overall dimensions, finished rough opening  
dimensions and installation specifics.  
IMPORTANT NOTE: A ground fault circuit  
interrupter (GFCI) is not recommended and may  
cause interruption of operation.  
IMPORTANT NOTE: Caution must be used in  
planning the proper installation of the Wolf gas  
range to avoid any fires or damage to adjacent  
cabinetry or kitchen equipment. Be sure to  
follow minimum clearances established in the  
finished rough opening dimensions as shown in  
the illustration on page 4.  
Wolf gas ranges are designed to operate on  
natural gas at 5" (12.5 mb) WC (water column)  
pressure or LP gas at 10" (25 mb) WC pressure.  
The minimum line pressure for natural gas is 7"  
(17.5 mb) WC and 11" (27.4 mb) WC for LP  
gas. The maximum gas supply pressure to the  
regulator should never exceed 14" (34.9 mb)  
WC; .5 psi (3.5 kPa).  
IMPORTANT NOTE: A minimum 5" (127) riser is  
required when installing a gas range against a  
combustible surface. A minimum 10" (254) riser  
is required when installing a gas range with a  
charbroiler or griddle against a combustible  
surface.  
Wolf recommends the use of a 1/2" (13) I.D.  
commercial type flex hose; this is the minimum  
size that may be used. All plumbing to the flex  
hose must be 3/4" (19) minimum I.D. pipe.  
IMPORTANT NOTE: A separate external gas  
shut-off valve must be located near the range in  
an accessible location.  
A Wolf Pro ventilation hood or hood liner is  
recommended. When installing a ventilation  
hood, refer to the specific requirements of the  
hood for the minimum dimension to countertop.  
Also refer to the ventilation recommendation  
charts in the Pro ventilation section of our  
website, wolfappliance.com.  
You must follow all National Electrical Code  
and gas regulations. In addition, be aware of  
local codes and ordinances when installing  
your services.  
Wolf gas ranges function up to 6,000'  
(1828 m) in altitude without any adjustment.  
Installations above 6,000' (1828 m) need the  
high altitude kit. Contact your Wolf dealer for  
details. To obtain local dealer information, visit  
the Showroom Locator section of our website,  
wolfappliance.com.  
The Wolf gas range requires a 110/120 V AC,  
50/60 Hz electrical supply to operate the  
electronic ignition system. The 6' (1.8 m) power  
supply cord provided with the range is  
equipped with a 3-prong, grounded plug for  
protection against shock hazard. The service  
should have its own 15 amp circuit breaker.  
Locate electrical within the shaded area shown  
in the illustration on page 4.  
Refer to the installation instructions  
shipped with each Wolf product for detailed  
specifications.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  

Well Traveled Living Fire Pit 60243 User Manual
Weslo Treadmill WATL271051 User Manual
Whirlpool Dehumidifier WGDH160UH User Manual
Whirlpool Washer Dryer LXR9245EQ0 User Manual
Woodstock Drill W1668 User Manual
Zanussi Clothes Dryer ZDC 5370 W User Manual
Zanussi Cooktop ZGF 643 User Manual
Zebra Technologies Power Screwdriver TTP 2030 User Manual
Zenith Car Satellite TV System P42W34 User Manual
Zenoah Brush Cutter T3002 95910101 User Manual