G A S C O O K T O P S
INSTALLATION INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F GAS COOKTOPS
INSTALLATION R E Q U I R E M E N T S
IMPORTANT NOTE: This installation must
be completed by a qualified installer,
service agency or gas supplier.
If the information in this book is
not followed exactly, a fire or
explosion may result, causing
property damage, personal injury
or death.
IMPORTANT NOTE: Save these Installation
Instructions for the local inspector’s use.
C O N TAC T
I N F O R M AT I O N
Please read the entire Installation Instruc-
tions prior to installation.
Installer: please retain these instructions
for local inspector’s reference, then leave
them with the homeowner.
Wolf Customer
Service:
800-332-9513
IMPORTANT NOTE:
Website:
wolfappliance.com
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Homeowner: please read and keep these
instructions for future reference and be
sure to read the entire Use & Care Infor-
mation prior to use.
Warranty service must be performed
by a Wolf authorized service center.
IMPORTANT NOTE: This appliance must be
installed in accordance with National Electri-
cal Codes, as well as all state, municipal and
local codes. The correct voltage, frequency
and amperage must be supplied to the appli-
ance from a dedicated, grounded circuit
which is protected by a properly sized circuit
breaker or time delay fuse. The proper
Do not store or use gasoline or
other flammable vapors and liquids
in the vicinity of this or any other
appliance.
A ventilation hood or downdraft
system is recommended (but not
required) for use with the Wolf gas
cooktop.
voltage, frequency, and amperage ratings are
listed on the product rating plate.
Record the model and serial numbers before
installing the cooktop. Both numbers are
listed on the rating plate, located on the
underside of the cooktop.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch.
Model Number
Serial Number
Do not use any phone in your
building.
Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
If you cannot reach your gas
supplier, call the fire department.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F GAS COOKTOPS
BEFORE YO U S TA RT
Proper installation is your responsibility.
Have a qualified technician install this
cooktop. You must also assure that electri-
cal installation is adequate and in compli-
ance with all local codes and ordinances.
C O M M O N W E A LT H O F M A S S AC H U S E T T S
Installations and repairs must be performed
by a qualified or licensed contractor,
plumber or gas fitter qualified or licensed
by the state, province, or region where this
appliance is being installed.
Wolf gas cooktops are manufactured for
use with natural gas or LP gas. Please
check product rating plate for type of gas
needed.
Use only gas shut-off valves approved for
use within the state, province, or region
where this appliance is being installed.
Proper gas supply connection must be
available; refer to Gas Supply Requirements
on page 10. Electrical ground is required;
see Electrical Requirements on page 11.
A flexible gas connector, when used, must
not exceed 3' (.9 m).
Check the location where the cooktop will
be installed. The location should be away
from strong draft areas, such as windows,
doors and strong heating vents or fans. Do
not obstruct flow of combustion and
ventilation air.
Make sure you have everything necessary
for correct installation. It is the responsibil-
ity of the installer to comply with the instal-
lation clearances specified on the product
rating plate. The rating plate can be found
on the underside of the cooktop.
This cooktop is intended for indoor use.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION I N S T R U C T I O N S
SITE P R E PA R AT I O N
C O U N T E RTO P C U T- O U T D I M E N S I O N S
L O C AT I O N R E Q U I R E M E N T S
IMPORTANT NOTE: Countertop opening
dimensions shown on the following pages
must be used. The dimensions shown provide
for required clearances.
Illustrations on the following pages provide the
overall dimensions, countertop cut-out and
installation specifications for Wolf gas
cooktops. Maintain the following minimum
installation dimensions:
These cooktops are designed to fit a standard
24" (610) deep base cabinet with a 25" (635)
deep countertop. Before making the counter-
top cut-out, verify that the cooktop will clear
the side walls of the base cabinet below. There
should be at least 51/2" (140) clearance
Minimum horizontal clearance from the
sides and back of the cooktop cut-out to
adjacent vertical combustible construction,
extending a minimum of 18" (457) above
the countertop, is as follows: 7" (178) from
side edges of cut-out for the 15" (381)
cooktop; 9" (229) from side edges of cut-out
for the 30" (762) and 36" (914) cooktops;
21/2" (64) from rear edge of cut-out.
between the countertop and any combustible
surface directly below the unit.
If the cabinet has a drawer, a 41/2" (114) depth
clearance from the countertop to the top of the
drawer (or other obstruction) in the base
cabinet is required. The drawer depth may
need to be shortened to avoid interfering with
the gas pressure regulator.
Minimum vertical distance between the
countertop and combustible materials
above the cooktop must be 30" (762).
Maximum 13" (330) depth of overhead side
cabinets directly above and within side
clearance.
IMPORTANT NOTE: Do not seal the cooktop
to the countertop. It must be removed if
service is necessary.
IMPORTANT NOTE: When installing a ventila-
tion hood, refer to the specific requirements
of the hood for the minimum dimension to
countertop.
Failure to locate the cooktop without the
proper clearances will result in a fire
hazard.
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F GAS COOKTOPS
INSTALLATION S P E C I F I C AT I O N S
The illustrations below provide the overall
dimensions, countertop cut-out and installation
specifications for Model CT15G.
IMPORTANT NOTE: When multiple cooktop
units are installed side by side, refer to the
countertop cut-out dimensions on page 9.
For Model CT15G, the gas service may be
supplied through the floor if the cooktop is not
installed above an oven. Refer to the illustration
for specifics on placement of gas and electrical.
I N S TA L L AT I O N S P E C I F I C AT I O N S – M O D E L C T 1 5 G
21"
(533)
OVERALL
DEPTH
15" (381)
OVERALL WIDTH
33" (838) RECOMMENDED
13" max
(330)
CABINET WIDTH
30" (762)
18"
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
7"*min (178)
CUT-OUT TO
(457)
14" (356)
COMBUSTIBLE COOKTOP CUT-OUT
1
1
2 /2"**
19 /4" (489)
1
(64) COOKTOP CUT-OUT
DEPTH
2 /2"min
MATERIALS
(BOTH SIDES)
WIDTH
ABOVE COOKTOP
4" (102)
(64)
4" (102)
Overall Dimensions
E
G
15"
36" (914)
(381)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
M O D E L C T 1 5 G D I M E N S I O N S
15"
(381)
LOCATION OF GAS
SUPPLY MAY ALSO
EXTEND 5" ON FLOOR
FROM BACK WALL
LOCATION OF GAS SUPPLY
MAY ALSO EXTEND 5" ON
FLOOR FROM BACK WALL
Overall Width
Overall Height
Overall Depth
15" (381)
4" (102)
5"
15"
(127)
(381)
21" (533)
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side with 33" (838) recommended cabinet width. 18" (457)
recommended cabinet width for installation of single 15" (381) cooktop or module. *Minimum clearance from both side edges of cooktop cut-out
to combustible materials up to 18" (457) above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up
to 18" (457) above countertop.
Recommended
Cabinet Width
33" (838)
14" (356)
COOKTOP CUT-OUT
WIDTH
Minimum Cabinet Depth 223/4" (578)
Minimum Height Clearance 4" (102)
Countertop Cut-Out
Cut-Out Width
Cut-Out Depth
14" (356)
1
19 /4" (489)
191/4" (489)
COOKTOP
CUT-OUT DEPTH
1
2 /2"min
(64)
Unit dimensions may vary to 1/8" (3).
FRONT OF COUNTERTOP
6
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION I N S T R U C T I O N S
INSTALLATION S P E C I F I C AT I O N S
The illustrations below provide the overall
dimensions, countertop cut-out and installation
specifications for Model CT30G.
If the Model CT30G is installed above cabinets,
the gas and electrical placement is not critical.
A grounded outlet needs to be placed within 4'
(1.2 m) of the right rear of the cooktop.
IMPORTANT NOTE: 33" (838) wide cabinets
are recommended for installation of Model
CT30G.
IMPORTANT NOTE: When multiple cooktop
units are installed side by side, refer to the
countertop cut-out dimensions on page 9.
A Wolf 30" (762) single built-in oven may be
installed below Model CT30G. For this installa-
tion, unless you are using cabinets deeper than
24" (610), it is recommended that the electrical
and gas supply be placed in the base cabinet to
the right of the oven. Refer to installation
instructions provided with the built-in oven for
additional specifications.
I N S TA L L AT I O N S P E C I F I C AT I O N S – M O D E L C T 3 0 G
21"
(533)
OVERALL
DEPTH
30" (762)
OVERALL WIDTH
33" (838) RECOMMENDED
CABINET WIDTH
13" max
(330)
30" (762)
18"
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
9"*min (229)
CUT-OUT TO
COMBUSTIBLE
MATERIALS
30"min (762)
(457)
1
1
2 /2"**
19 /4" (489)
29" (737) COOKTOP
CUT-OUT WIDTH
1
(64) COOKTOP CUT-OUT
DEPTH
2 /2"min
ABOVE COOKTOP
4" (102)
(64)
(BOTH SIDES)
4" (102)
1
E
G
3 /2" (89)
Overall Dimensions
3
(95)
3 /4"min
10"
24"min
(610)
36" (914)
(254)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
30-INCH OVEN OPENING
M O D E L C T 3 0 G D I M E N S I O N S
Overall Width
Overall Height
Overall Depth
30" (762)
4" (102)
21" (533)
*Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 18" (457) above countertop.
**Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 18" (457) above countertop.
Recommended
Cabinet Width
33" (838)
29" (737)
COOKTOP CUT-OUT WIDTH
Minimum Cabinet Depth 223/4" (578)
Minimum Height Clearance 4" (102)
Countertop Cut-Out
Cut-Out Width
Cut-Out Depth
29" (737)
1
19 /4" (489)
191/4" (489)
COOKTOP
CUT-OUT DEPTH
1
(64)
2 /2"min
Unit dimensions may vary to 1/8" (3).
FRONT OF COUNTERTOP
Dimensions in parentheses are in
millimeters unless otherwise specified.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F GAS COOKTOPS
INSTALLATION S P E C I F I C AT I O N S
The illustrations below provide the overall
dimensions, countertop cut-out and installation
specifications for Model CT36G.
If the Model CT36G is installed above cabinets,
the gas and electrical placement is not critical.
A grounded outlet needs to be placed within 4'
(1.2 m) of the right rear of the cooktop.
IMPORTANT NOTE: 39" (991) wide cabinets
are recommended for installation of Model
CT36G.
When a 36" (914) built-in oven is installed
below Model CT36G, it is recommended that
the rough opening for the oven be 73/4" (197)
from the floor to ease the use of the oven door.
A Wolf 36" (914) built-in oven may be installed
below Model CT36G. For this installation,
unless you are using cabinets deeper than 24"
(610), it is recommended that the electrical and
gas supply be placed in the base cabinet to the
right of the oven. Refer to installation instruc-
tions provided with the built-in oven for addi-
tional specifications.
IMPORTANT NOTE: When multiple cooktop
units are installed side by side, refer to the
countertop cut-out dimensions on page 9.
I N S TA L L AT I O N S P E C I F I C AT I O N S – M O D E L C T 3 6 G
21"
(533)
OVERALL
DEPTH
36" (914)
OVERALL WIDTH
39" (991)
13" max
(330)
RECOMMENDED CABINET WIDTH
36"min (914)
30" (762)
18"
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
9"*min (229)
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(457)
1
1
2 /2"**
19 /4" (489)
35" (889)
COOKTOP CUT-OUT WIDTH
1
(64) COOKTOP CUT-OUT
DEPTH
2 /2"min
ABOVE COOKTOP
4" (102)
(64)
(BOTH SIDES)
4" (102)
1
E
G
3 /2" (89)
Overall Dimensions
3
3 /4"min (95)
10"
24"min
(610)
36" (914)
(254)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
36-INCH OVEN OPENING
M O D E L C T 3 6 G D I M E N S I O N S
Overall Width
Overall Height
Overall Depth
36" (914)
4" (102)
21" (533)
*Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 18" (457) above countertop.
**Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 18" (457) above countertop.
Recommended
Cabinet Width
39" (991)
35" (889)
COOKTOP CUT-OUT WIDTH
Minimum Cabinet Depth 223/4" (578)
Minimum Height Clearance 4" (102)
Countertop Cut-Out
Cut-Out Width
Cut-Out Depth
35" (889)
1
19 /4" (489)
191/4" (489)
COOKTOP
CUT-OUT DEPTH
1
(64)
2 /2"min
Unit dimensions may vary to 1/8" (3).
FRONT OF COUNTERTOP
8
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION I N S T R U C T I O N S
VENTILATION O P T I O N S
INSTALLATION O P T I O N S
IMPORTANT NOTE: It is recommended that
you operate the Wolf gas cooktop with either a
Wolf cooktop ventilation hood, downdraft
system or Pro ventilation hood. Contact your
Wolf dealer for details.
M U LT I P L E C O O K TO P I N S TA L L AT I O N
If the gas cooktop is to be used with any
combination of additional cooktop units or
modules with a filler strip, the cut-out width is
calculated by adding the corresponding units'
cut-out dimensions plus 11/4" (32) for each
additional unit. Refer to the illustration below.
O P T I O N A L
I N S TA L L AT I O N S
Cooktop Wall Hood – 30" (762) or 36" (914)
widths in classic stainless steel.
Cooktop Island Hood – 42" (1067) width in
classic stainless steel.
IMPORTANT NOTE: When multiple units are
installed side by side, each unit must have its
own separate recommended electrical circuit.
When multiple gas units are installed next to
one another, they can receive their gas supply
from a common line. However, each unit
MUST have its own regulator installed
Dimensions will
vary according to
the specific
Downdraft Ventilation System – 30" (762),
36" (914) or 45" (1143) widths, with top
cover and control panel in classic, platinum
and carbon stainless steel finishes (45"
downdraft available in classic finish only).
installation.
between the mainline and the gas cooktop.
Pro Wall Hood – 22" (559), 24" (610) or 27"
(686) depths and 30" (762) to 66" (1676)
widths in classic stainless steel.
When two or more modules are installed
together, an integrated module filler strip
(IFILLER/S) is recommended. If a downdraft
ventilation system is also installed, an inte-
grated module support for downdraft ventila-
tion (ISUPPORT) is also required (Model DD30
only). Contact your Wolf dealer for information
on these accessory components.
Pro Island Hood – 36" (914) to 66" (1676)
widths in classic stainless steel.
Pro Hood Liner – available in widths to
accommodate 30" (762) to 60" (1524) hood
shells.
All hoods have welded seams, sealed halogen
lighting and removable, dishwasher-safe
filters.
Blower requirements may vary due to the
length of ducting and number of angles. The
basic recommendation is 1 CFM per 100 Btu/hr
(.03 kW). Always consult your HVAC profes-
sional for more concise blower requirements.
3
59 /4" (1518) FOUR MODULES WIDTH OR
1
59 /2" (1511) 30" COOKTOP AND TWO MODULES OR
50 /4" (1276) 36" COOKTOP AND ONE MODULE
IMPORTANT NOTE: When installing a ventila-
tion hood, refer to the specific requirements
of the hood for the minimum dimension to
countertop.
1
1
44 /2" (1130) THREE MODULES WIDTH OR
44 /4" (1124) 30" COOKTOP AND ONE MODULE
1
1
29 /4" (743)
TWO MODULES WIDTH
1
14"
(356)
19 /4"
(489)
CUT-OUT
WIDTH
CUT-OUT
DEPTH
1
(64)
2 /2"min
FRONT OF COUNTERTOP
Countertop cut-out dimensions for installation of multiple cooktops
Dimensions in parentheses are in
millimeters unless otherwise specified.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F GAS COOKTOPS
GAS SUPPLY R E Q U I R E M E N T S
If local codes permit, a new CSA design-
certified, 4–5' (1.2–1.5 m) long, 1/2" or 3/4" ID,
flexible metal appliance connector is recom-
mended for connecting this cooktop to the gas
supply line. Do not kink or damage the flexible
connector when moving the cooktop. The
pressure regulator has 1/2" female pipe threads.
You will need to determine the fittings
required, depending on the size of your gas
supply line, flexible metal connector and shut-
off valve.
EXPLOSION HAZARD—
Use a new CSA approved gas supply line
and install a gas shut-off valve.
I M P O RTA N T
N OT E
Securely tighten all gas connections.
For LP gas, have a qualified technician
make sure the gas pressure does not
exceed 14" (34.9 mb) WC (water column).
This installation
must conform with
local codes and
ordinances. In the
absence of local
codes, installations
must conform with
the American
National Standard,
National Fuel Gas
Code and National
Electrical Code
Failure to do so can result in explosion,
fire or death.
If rigid pipe is used as a gas supply line, a
combination of pipe fittings must be used to
obtain an in-line connection to the cooktop. All
strains must be removed from the supply and
gas lines so the cooktop will be level and in
line.
IMPORTANT NOTE: The gas cooktop must be
connected to a regulated gas supply.
IMPORTANT NOTE: This installation must
conform with local codes and ordinances. In
the absence of local codes, installations must
conform with American National Standard,
National Fuel Gas Code ANSI Z223.1 – latest
edition or CANI – B149.1 or 2.
IMPORTANT NOTE: The supply line must
be equipped with an approved external gas
shut-off valve located near the cooktop in an
accessible location. Do not block access to the
shut-off valve. Refer to the illustration below.
regulations.
IMPORTANT NOTE: The natural gas cooktop
is rated for elevations up to 8,000' (2438 m)
without adjustment. Install a high altitude kit
for elevations from 8,000' (2438 m) to 10,000'
(3084 m). The LP gas cooktop is rated for
10,000' (3084 m).
The inlet pressure to the regulator should be
as follows for operation and checking the regu-
lator setting:
Natural Gas: Set pressure 5" (12.5 mb) WC,
supply pressure 7–14" (17.5–34.9 mb) max.
LP Gas: Set pressure 10" (25 mb) WC,
supply pressure 11–14" (27.4–34.9 mb) WC.
The cooktop is equipped for use with natural
or LP gas. It is design certified by the Canadian
Standards Association (CSA) for natural or LP
gases. The rating plate, located on the under-
side of the burner box, has information on the
type of gas that should be used. If this infor-
mation does not agree with the type of gas
available, check with the local gas supplier.
SHUT-OFF VALVE
Open Position
Provide a gas supply line of 3/4" rigid pipe to
the cooktop location. A smaller size pipe on
long runs may result in insufficient gas supply.
Pipe joint compounds, suitable for use with LP
gas should be used. For LP gas, piping or
tubing size can be 1/2" minimum. LP gas suppli-
ers usually determine the size and materials
used on the system.
Gas Supply
To Appliance
Line
Shut-off valve
10
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION I N S T R U C T I O N S
GAS SUPPLY R E Q U I R E M E N T S
L I N E P R E S S U R E T E S T I N G
A 120 VAC, 60 Hz, 15-amp, fused electrical
supply is required. A time-delay fuse or circuit
breaker is recommended. It is recommended
that a separate circuit serving only this appli-
ance be provided.
Testing above 1/2 psi (3.5 kPa) 14" (34.9 mb)
WC (gauge): The cooktop and its individual
shut-off valve must be disconnected from
the gas supply piping system during any
pressure testing of that system at test pres-
sures greater than 1/2 psi (3.5 kPa).
C O N TAC T
I N F O R M AT I O N
Electronic ignition systems operate within
wide voltage limits, but proper ground and
polarity are necessary. In addition to checking
that the outlet provides 120 VAC power and is
correctly grounded, the outlet must be checked
by a qualified electrician to see if it is wired
with correct polarity. A wiring diagram is
provided in the literature package.
Testing below 1/2 psi (3.5 kPa) 14" (34.9 mb)
WC (gauge) or lower: The cooktop must be
isolated from the gas supply piping system
by closing its individual manual shut-off
valve during any pressure testing of the gas
supply piping system at test pressures
equal to or less than 1/2 psi (3.5 kPa).
Copies of the
standards listed
may be obtained
from:
*National Fire
Protection
Association
Batterymarch Park
Quincy,
This appliance, when installed, must be electri-
cally grounded in accordance with local codes
or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70 latest
edition or Canadian Electrical Code (CSA).
ELECTRICAL R E Q U I R E M E N T S
Massachusetts
02269
**Canadian
Standard
Association
178 Rexdale Blvd.
Etobicoke
ELECTRICAL SHOCK HAZARD—
Plug into a grounded 3-prong adapter.
Do not remove ground prong.
Do not use an adapter.
R E C O M M E N D E D G RO U N D M E T H O D
IMPORTANT NOTE: For your personal safety,
this cooktop must be grounded. This cooktop
is equipped with a 3-prong ground plug. To
minimize possible shock hazard, the cord must
be plugged into a mating 3-prong ground-type
outlet, grounded in conformance with the
National Electrical Code, ANSI/NFPA 70 latest
edition*, or Canadian Electrical Code (CSA)**
and all local codes and ordinances. If a mating
outlet is not available, it is the obligation of
the customer to have a properly grounded,
3-prong outlet installed by a qualified electri-
cian.
(Toronto), Ontario
M9W 1R3
Failure to follow these instructions can
result in electric shock, fire or death.
IMPORTANT NOTE: If codes permit and a
separate ground wire is used, it is recom-
mended that a qualified electrician determine
that the ground path is adequate.
IMPORTANT NOTE: Check with a qualified
electrician if you are not sure whether the
cooktop is properly grounded.
IMPORTANT NOTE: If product is connected to
a GFCI protected outlet, nuisance tripping of
power supply may occur, resulting in loss of
product operation.
IMPORTANT NOTE: Do not ground to a gas
pipe.
W I R I N G D I AG R A M
A wiring diagram covering the control circuit
for each Wolf gas cooktop model can be found
on page 15.
Dimensions in parentheses are in
millimeters unless otherwise specified.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F GAS COOKTOPS
C O O K TO P INSTALLATION
Remove the cooktop, pressure regulator,
burner grates and burner caps from the
shipping package.
P R E S S U R E R E G U L ATO R
Install the pressure regulator with the arrow on
the regulator pointing up toward the unit and
in a position where you can reach the access
cap. Refer to the illustration below.
Lower the cooktop into the countertop cut-out
opening. Center the cooktop in the opening
and check that the front edge of cooktop is
parallel to the front edge of the countertop.
Check that all required clearances are met. Use
a pencil to outline the rear edge of the cooktop
on the countertop. Remove the cooktop from
the countertop opening.
IMPORTANT NOTE: All connections must be
wrench-tightened. Do not make connections to
the gas regulator too tight, as this may crack
the regulator and cause a gas leak. Do not
allow the regulator to turn on the pipe when
tightening fittings.
IMPORTANT NOTE: When repositioning the
cooktop in the countertop cut-out opening, lift
the entire cooktop up from the opening to
prevent scratching the countertop.
Remove the foam strip from the hardware
package. Apply the foam strip around the
bottom of the burner box flush with the edge
as shown in the illustration below.
Reinsert the cooktop into the countertop
opening. Check that the cooktop is parallel to
the front edge of the countertop. Lift the entire
cooktop to make adjustments and align the
rear edge with the pencil line.
Attach the brackets to the burner box. Insert
the 31/2" (89) clamping screws into the
brackets. Use a screwdriver to tighten the
clamping screws against the underside of the
countertop. Refer to the illustration below. Do
not overtighten screws.
Countertop
Burner Box
Bracket
Cooktop
Burner Box
Foam
Strip
Pressure
Regulator
Rear of
Cooktop
Access
Cap
Gas Flow –
Arrow
Points Up
1
3 /2" (89)
Bracket
Screws
Clamping
Screw
Foam strip application
Bracket installation
Pressure regulator
12
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION I N S T R U C T I O N S
C O O K TO P INSTALLATION
SURFACE B U R N E R S
G A S S U P P LY L I N E C O N N E C T I O N
I N I T I A L L I G H T I N G
Assemble the flexible metal connector from
the gas supply pipe to the pressure regulator.
You will need to determine the fittings
required, depending on the size of your gas
supply line, flexible metal connector and shut-
off valve. Refer to the illustration below.
The surface burners use electronic igniters in
place of standing pilots. When the cooktop
control knob is pushed in and turned to the
HIGH position, the system creates a spark to
light the burner. This sparking continues until
the electronic ignition senses a flame.
Use a pipe-joint compound made for use with
natural and LP gas. If a flexible metal connec-
tor is used, be sure the tubing is not kinked.
Be sure to place the burner heads and caps on
each burner base and position the burner
grates over the burner bases and heads before
lighting.
Open the shut-off valve in the gas supply line.
Wait a few minutes for the gas to move
through the line. Refer to the illustration on
page 10.
To check operation of the surface burners,
push in and turn each control knob to the HIGH
position. The flame should light within four
seconds.
G A S L E A K T E S T I N G
If the burners do not light properly, turn
control knob to the OFF position. Check that
the burner heads and caps are in the proper
position. Check that the power supply cord is
plugged in and that the circuit breaker or
house fuse has not blown. Check that the shut-
off valve is in the ON position. Check operation
again, if the burners do not light properly at
this point, contact a Wolf authorized service
center.
Use a brush and liquid detergent to test all gas
connections for leaks. Bubbles around connec-
tions will indicate a leak. If a leak appears, shut
off gas valve controls and adjust connections.
Then check connections again. Clean all the
detergent solution from the cooktop.
Never test for a gas leak with a match or
other flame.
IMPORTANT NOTE: Initial lighting of the
surface burners may take slightly longer, as air
in the system must be purged before gas can
be supplied to the burner.
Pressure
Regulator
Shut-Off
Valve
1
1
/2" Adapter
/2" Adapter
Flexible Metal
Connector
1
1
/2" Nipple
(use pipe-joint
/2" Nipple
(use pipe-joint
compound on ends)
compound on ends)
Gas supply line connection
Dimensions in parentheses are in
millimeters unless otherwise specified.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F GAS COOKTOPS
COOKTOP R E M OVA L
I F YO U N E E D SERVICE
If it is necessary to remove the cooktop for
cleaning or service, shut off the gas supply.
Disconnect the gas and electric supply.
Remove the mounting brackets on the right
and left side of the burner box and remove the
cooktop. Reinstall in the reverse order and
check the gas connection for leaks.
If service is necessary, maintain the quality
built into your gas cooktop by calling a Wolf
authorized service center.
To obtain the name and number of a
Wolf authorized service center, check
the Locator section of our website,
wolfappliance.com or call Wolf Customer
C O N TAC T
I N F O R M AT I O N
Service at 800-332-9513
.
Wolf Customer
Service:
800-332-9513
TROUBLES H O OT I N G
When calling for service, you will need the
cooktop model and serial numbers. Both
numbers are listed on the rating plate,
located on the underside of the cooktop.
IMPORTANT NOTE: If the cooktop does not
operate properly, follow these troubleshooting
steps:
Website:
wolfappliance.com
Verify that power is being supplied to the
cooktop.
Check that gas valves are turned to the ON
position.
Check the gas supply and electrical
connections to ensure that the installation
has been completed correctly.
Follow troubleshooting procedures as
described in the Wolf Gas Cooktops
Use & Care Information.
If the cooktop still does not work, contact
a Wolf authorized service center. Do not
attempt to repair the cooktop yourself. Wolf
is not responsible for service required to
correct a faulty installation.
The information and images are the copyright
property of Wolf Appliance Company, Inc., an
affiliate of Sub-Zero Freezer Company, Inc.
Neither this book nor any information or images
contained herein may be copied or used in whole
or in part without the express written permission
of Wolf Appliance Company, Inc., an affiliate of
Sub-Zero Freezer Company, Inc.
©Wolf Appliance Company, Inc. all rights reserved.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION I N S T R U C T I O N S
WIRING D I AG R A M S
R SPARK
MODULE
3 CONDUCTOR
POWER CORD
WHITE
GRN
WHITE
1
2
1
2
N
A
BLK
BLACK
RED
WHITE
WHITE
N
A
F SPARK
MODULE
RED
WHITE
REAR
WHITE
BLK
Model CT15G
FRONT
LR SPARK
MODULE
RR SPARK
MODULE
3 CONDUCTOR
POWER CORD
WHITE
WHITE
N
N
A
1
2
1
BLK
2
IGN
GRN
IGN
A
RED
RED
BLACK
RED
WHITE
WHITE
N
N
A
IGN
IGN
A
RED
RED
LF SPARK
MODULE
RF SPARK
MODULE
RED
WHITE
WHITE
BLK
BLK
BLK
LEFT
RIGHT
REAR
REAR
WHITE
WHITE
BLK
RED
RED
BLK
Model CT30G
LEFT
RIGHT
FRONT
FRONT
LR SPARK
MODULE
CR SPARK
MODULE
RR SPARK
MODULE
3 CONDUCTOR
POWER CORD
WHITE
WHITE
N
N
A
N
A
1
2
1
2
IGN
IGN
GRN
IGN
A
BLK
RED
RED
BLACK
RED
WHITE
WHITE
N
N
A
IGN
IGN
A
RED
RED
LF SPARK
MODULE
CF SPARK
MODULE
RE
RED
RED
WHITE
WHITE
WHITE
BLK
BLK
BLK
LEFT
CEN
RIGHT
REAR
REAR
REAR
WHITE
WHITE
BLK
RED
RED
BLK
LEFT
CEN
FRONT
FRONT
Model CT36G
15
Download from Www.Somanuals.com. All Manuals Search And Download.
WOLF APPLIANCE COMPANY, INC.
P. O. BOX 44848
MADISON, WI 53744
800-332-9513
WOLFAPPLIANCE.COM
8 0 7 6 0 5 R E V- B
1 0 / 2 0 0 6
Download from Www.Somanuals.com. All Manuals Search And Download.
|