High-Efficiency
Direct-Vent Furnaces
A high-efficiency, low-profile
furnace that may be installed
nearly anywhere. Great for
homes, apartments, offices,
garages and room additions
Just minutes are all that is needed to warm
up your room while enjoying the money-
saving, high-efficiency design, modern
appearance and low-cost installation.
Williams' high-efficiency direct-vent
furnaces require no inside air for operation.
making them an ideal choice for safe
operation to add comfort to nearly
anyplace heat is needed.
17,700 Btu/hr
Model Series 17735
Model Series 29035 and 17735
Features a humidifier, programmable timer/clock, electronic ignition and
a whisper-quiet blower system.
Design Features
29,400 Btu/hr
Model Series 29035
Efficiency Ratings:
- 7,400 Btu/hr. Series: 79%
- 17,700 and 29,000 Btu/hr. Series: 82%
Easy installation -- all vent material included
Attractive, durable fresh-white finish.
Natural and propane models
Unique wall-mount design frees up floor space
Small, low-profile vent size
Model
Series
07435
These models
require no
electricity
– great during
power outages.
Sealed-combustion safety technology uses no
inside room air for operation.
7,400 Btu/hr
Download from Www.Somanuals.com. All Manuals Search And Download.
High-Efficiency Direct-Vent Furnaces
Model Number
Accessories
Natural
Propane
Btu/hr Input Rating
Btu/hr Output Rating
Efficiency Percentage
Thermal
0773512
1773512
1773511
17,700
2903512
0773511
7,400
5,850
2903511
29,000
23,817
14,514
79
82
82
Dimensions
Fragrance Holder
Towel Warmer
Width
Depth
Height
18⅞"
6¾"
22¾"
3⅞"
2⅜"
---
4⅛"
---
---
21¾"
8¼"
28⅛"
1⅞"
1⅜"
39 db
2"
39⅝"
8¼"
28⅛"
1⅞"
1⅜"
41 db
2"
17735 Series Accessories
Umbrella Holder
Warming Tray
Air Inlet Pipe Diameter
Exhaust Pipe Diameter
Noise Level at 10' may speed
Wall Hole Diameter
Electrical Supply
Air Flow (cfm)
Vent Adapter (17735 & 29035 Series)
110 Volts
129
110 Volts
265
The Vent Adapter Accessory is used to compensate for the extra
space left around the vent hole when replacing a furnace with a
larger vent opening. It can also be used to extend the flue
terminal on homes with vinyl siding so that the vent cap lies
flush against the edge of the siding.
Total Electrical Load
Maximum Wall Thickness
Type of Control
Shipping Weight (lbs.)
---
86
140
19½"
Built-In
44
19⅝"
Built-In
57
19⅝"
Built-In
93
Gas connection: ½"
·
All models are rated for 2,000' elevation.
Features
ꢀ
ꢀ
ꢀ
Unique wall-mount design frees up critical floor space
Electronic ignition
Air-to-air system offers instant heating
17735 and 29035 Series
Humidification System
Relieve the effects of dry winter air. Built-in humidifier keeps
air soft and moist in dry weather.
Programmable Timer
A
programmable thermostat in your home is one of the
easiest ways to save energy and money. On/off, seven-day
timer/clock.
Summertime Ventilation
For clean, comfortable heat when and where you want it. The gas flame is completely
sealed inside, away from all contact with room air. Air necessary for combustion is
drawn into the chamber from outside through direct wall vent, and all combustion
products are vented directly to the outside. Only clean, gentle heat, in continuous
circulation is delivered into the room. Windows and doors can stay closed because no
room air is used for combustion.
A two-speed recirculating fan will move the cool air off the
floor and circulate it throughout your home to keep it more
comfortable .
Air Filter
Termination Cap (Flue)
Easy access, keeps the fans clean
and is low maintenance.
Small, low-profile termination
cap goes on the exterior of the
building.
29035 Series
07735 Series
Important
· Read owner's manual before using/installing.
No electricity required
· Photographs are representative.
· Check local codes and ordinances for permitted uses.
· Consult installation manual for clearances prior to installation.
· We reserve to right to amend product specifications without notice.
· Installation and servicing recommended by a qualified service person.
· Venting must comply with the installation manual.
250 West Laurel Street · Colton, California 92324 USA
(909) 825-0993 · Fax: (909) 370-0581 or (909) 824-8009
Consumer Line: (888) 256-6465
· Please read the warranty for any limitations for disclaimers.
Homeowner Assistance: (909) 426-0978
· Combustion chamber carries a ten-year limited warranty. All other parts carry a one-year limited warranty.
© 2009 Williams Furnace Co.
Printed in U.S.A.
All Rights Reserved
Subject to Change without Notice
L1457
Download from Www.Somanuals.com. All Manuals Search And Download.
|