Williams Furnace 07435 User Manual

High-Efficiency  
Direct-Vent Furnaces  
A high-efficiency, low-profile  
furnace that may be installed  
nearly anywhere. Great for  
homes, apartments, offices,  
garages and room additions  
Just minutes are all that is needed to warm  
up your room while enjoying the money-  
saving, high-efficiency design, modern  
appearance and low-cost installation.  
Williams' high-efficiency direct-vent  
furnaces require no inside air for operation.  
making them an ideal choice for safe  
operation to add comfort to nearly  
anyplace heat is needed.  
17,700 Btu/hr  
Model Series 17735  
Model Series 29035 and 17735  
Features a humidifier, programmable timer/clock, electronic ignition and  
a whisper-quiet blower system.  
Design Features  
29,400 Btu/hr  
Model Series 29035  
Efficiency Ratings:  
- 7,400 Btu/hr. Series: 79%  
- 17,700 and 29,000 Btu/hr. Series: 82%  
Easy installation -- all vent material included  
Attractive, durable fresh-white finish.  
Natural and propane models  
Unique wall-mount design frees up floor space  
Small, low-profile vent size  
Model  
Series  
07435  
These models  
require no  
electricity  
great during  
power outages.  
Sealed-combustion safety technology uses no  
inside room air for operation.  
7,400 Btu/hr  
Download from Www.Somanuals.com. All Manuals Search And Download.  
High-Efficiency Direct-Vent Furnaces  
Model Number  
Accessories  
Natural  
Propane  
Btu/hr Input Rating  
Btu/hr Output Rating  
Efficiency Percentage  
Thermal  
0773512  
1773512  
1773511  
17,700  
2903512  
0773511  
7,400  
5,850  
2903511  
29,000  
23,817  
14,514  
79  
82  
82  
Dimensions  
Fragrance Holder  
Towel Warmer  
Width  
Depth  
Height  
18"  
6¾"  
22¾"  
3"  
2"  
---  
4"  
---  
---  
21¾"  
8¼"  
28"  
1"  
1"  
39 db  
2"  
39"  
8¼"  
28"  
1"  
1"  
41 db  
2"  
17735 Series Accessories  
Umbrella Holder  
Warming Tray  
Air Inlet Pipe Diameter  
Exhaust Pipe Diameter  
Noise Level at 10' may speed  
Wall Hole Diameter  
Electrical Supply  
Air Flow (cfm)  
Vent Adapter (17735 & 29035 Series)  
110 Volts  
129  
110 Volts  
265  
The Vent Adapter Accessory is used to compensate for the extra  
space left around the vent hole when replacing a furnace with a  
larger vent opening. It can also be used to extend the flue  
terminal on homes with vinyl siding so that the vent cap lies  
flush against the edge of the siding.  
Total Electrical Load  
Maximum Wall Thickness  
Type of Control  
Shipping Weight (lbs.)  
---  
86  
140  
19½"  
Built-In  
44  
19"  
Built-In  
57  
19"  
Built-In  
93  
Gas connection: ½"  
·
All models are rated for 2,000' elevation.  
Features  
Unique wall-mount design frees up critical floor space  
Electronic ignition  
Air-to-air system offers instant heating  
17735 and 29035 Series  
Humidification System  
Relieve the effects of dry winter air. Built-in humidifier keeps  
air soft and moist in dry weather.  
Programmable Timer  
A
programmable thermostat in your home is one of the  
easiest ways to save energy and money. On/off, seven-day  
timer/clock.  
Summertime Ventilation  
For clean, comfortable heat when and where you want it. The gas flame is completely  
sealed inside, away from all contact with room air. Air necessary for combustion is  
drawn into the chamber from outside through direct wall vent, and all combustion  
products are vented directly to the outside. Only clean, gentle heat, in continuous  
circulation is delivered into the room. Windows and doors can stay closed because no  
room air is used for combustion.  
A two-speed recirculating fan will move the cool air off the  
floor and circulate it throughout your home to keep it more  
comfortable .  
Air Filter  
Termination Cap (Flue)  
Easy access, keeps the fans clean  
and is low maintenance.  
Small, low-profile termination  
cap goes on the exterior of the  
building.  
29035 Series  
07735 Series  
Important  
· Read owner's manual before using/installing.  
No electricity required  
· Photographs are representative.  
· Check local codes and ordinances for permitted uses.  
· Consult installation manual for clearances prior to installation.  
· We reserve to right to amend product specifications without notice.  
· Installation and servicing recommended by a qualified service person.  
· Venting must comply with the installation manual.  
250 West Laurel Street · Colton, California 92324 USA  
(909) 825-0993 · Fax: (909) 370-0581 or (909) 824-8009  
Consumer Line: (888) 256-6465  
· Please read the warranty for any limitations for disclaimers.  
Homeowner Assistance: (909) 426-0978  
· Combustion chamber carries a ten-year limited warranty. All other parts carry a one-year limited warranty.  
© 2009 Williams Furnace Co.  
Printed in U.S.A.  
All Rights Reserved  
Subject to Change without Notice  
L1457  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weider Home Gym WEBE13011 User Manual
Whirlpool Clothes Dryer 8316557 User Manual
Whirlpool Dishwasher W10275146A User Manual
Whirlpool Range FES340V User Manual
Yamaha Projector DPX1000 User Manual
Zanussi Fryer 200352 User Manual
Zanussi Refrigerator 113153 User Manual
Zanussi Refrigerator ZTR 57 R User Manual
Zenith Computer Monitor C27V28 User Manual
Zenith Water Dispenser 30009 User Manual