| WHITE-RODGERS WALL THERMOSTATS   HEATING/COOLING AND COOLING ONLY ASTRO* STATS WITH   SELECTOR-SWITCHES   • DUSTPROOF SEALED MERCURY CELLS OR SNAP-ACTION CONTACTS WITH   DUSTCOVER   • • • • • BEIGE CASE WITH GOLD TONE DIAL   POSITIVE CONTACT SNAP-SWITCHES ON SUBBASE   BIMETAL THERMOMETER   CLEAR FACEPLATE - REMOVABLE FOR EASY CLEANING   HEATING AND COOLING ANTICIPATORS PROVIDE NARROW DIFFERENTIAL   CONTROL OF ROOM TEMPERATURE   Part No.: 1D56-310   1F56-301   1F56-444   1E56-444   P574   P574   P574   P577   1D56-301 SHOWN   1F56-444 SHOWN   1E56-444 SHOWN   ASTROSTATS WITH SNAP ACTION SWITCH   • • • • SNAP ACTION CONTACTS WITH DUST COVER   NON-SUSCEPTIBLE TO SLIGHT JARS AND VIBRATIONS   IDEAL FOR MOBILE HOME USE   HEATING AND/OR COOLING ANTICIPATORS PROVIDE A NARROW DIFFERENTIAL CONTROL   OF ROOM TEMPERATURE   Part No.: 1D30-316   1C30-302   P578   1D30-316 SHOWN   HEAT PUMP THERMOSTAT   • • MANUAL CHANGEOVER   DUAL MERCURY CELL ARRANGEMENT ON A SINGLE BI-METAL PROVIDES CONTROL   WITHOUT COMPLICATED GEAR AND LEVER ARRANGEMENTS   • • THERMOSTAT MOUNTS TO SUBBASE WITH POSITIVE CAPTIVE SCREWS   SUBBASE TERMINAL SCREWS SPACED AND IDENTIFIED FOR EASY INSTALLATION   Part No.: 1F58-058   P583   202   Download from Www.Somanuals.com. All Manuals Search And Download.   WHITE-RODGERS WALL THERMOSTATS   COMFORT-SET 80 SERIES SINGLE STAGE DIGITAL THERMOSTATS (cont)   STANDARD FEATURES:   • • • • Choice of 5/1/1 day or 7 day programmable or non-programmable   4 time and 4 temperature settings per program (heat & cool)   Energy savings up to 33%   Patented pre-programmed software simplifies time and temperature   programming   • • • Indefinite setpoint Hold or programmable timed Hold up to 8 hours   Temporary temperature override until next program period   Dual-Powered…choice of battery-powered or hardwired, for all single   stage applications   • • • Selectable Energy Management recovery   Meets ENERGY STAR® specifications   Meets California Building Code, Title 24   Single Stage   2 Programs   Part No.: 1F80-261   COMFORT-SET 90 SERIES SINGLE STAGE DIGITAL THERMOSTATS   STANDARD FEATURES:   Single Stage   3 Programs   • Choice of 7 or 5/1/1 day or 7 day programmable or   non-programmable   Part No.: 1F90-371   • • • 4 time and 4 temperature settings per program (heat & cool)   Energy savings up to 33%   Patented pre-programmed software simplifies time and   temperature programming   Single Stage   7 Programs   • • • • • • Large Comfort-View™ luminescent display   Permanent program retention   Vacation programming   Part No.: 1F97-371   Air filter change indicator   Daylight Savings Time quick-change button   Temporary temperature override from 15 minutes to 19 hours or   indefinite setpoint hold   • • • • • • • • • • • Display temperature recalibration (+/-5º)   Maintains room temperature differential within .8 degree   Automatic Heat/Cool System Changeover   Selectable Energy Management Recovery   Built-in system and thermostat diagnostics   Digital-signal remote sensors (optional)   Meets ENERGY STAR® specifications   Meets California Building Code, Title 24   Compressor lockout protection   Millivolt compatible   Electric heat option   P4556   204   Download from Www.Somanuals.com. All Manuals Search And Download.   WHITE-RODGERS WALL THERMOSTATS   COMFORT-SET 90 SERIES MULTI STAGE & HEAT PUMP   DIGITAL THERMOSTATS   STANDARD FEATURES:   Heat Pump   • • Heat pump warm air start   Energy Source Optimizer selects heat pump or fossil fuel   • • 7-day programming   Four pre-programmed time/temperature periods per   day   Part No.: 1F94-371   • • • • Vacation Programming button   Programmable fan continuous in any period   Programmable fan on/off delays   Separate set-up menus: Installer menu, User menu,   Keypad lockout (total/partial) menu   Large Comfort-View™ display and lighted keypad   Permanent program retention – no batteries required   Daylight Savings Time quick-change button   Air filter change indicator   Multi Stage   Part No.: 1F95-371   • • • • • • • • Ignition control reset   Remote sensing (optional)   Outdoor temperature sensing (optional)   Multi-stage,heat pump, or single stage up to 3-stage   heat/2-stage cool   • • • • • • • Auto-changeover   EMR (Energy Management Recovery)   Meets ENERGY STAR® specifications   Meets California Building Code, Title 24   Compressor lockout/Auxiliary run time   Adjustable differential   Telephone access run program (X10 module   required)   205   Download from Www.Somanuals.com. All Manuals Search And Download.   TOTALINE THERMOSTAT GUARDS   THERMOSTAT GUARDS   • • • • • • Metal: beige   Plastic: beige or clear   Sizes fit most thermostats   Solid and ring bases   Have key lock   P593   Metal   Virtually tamper proof   P594   Plastic   Metal   WIDTH (in.)   3-7/8   5-1/4   5-1/4   6-3/8   6-3/8   6 HEIGHT (in.)   3-1/2   DEPTH (in.)   BASE   Solid   Solid   Ring   Solid   Ring   Ring   Solid   Solid   Ring   STYLE   Beige   Beige   Beige   Beige   Beige   Beige   Beige   Beige   Beige   PART NO.   2-1/2   3 3-1/4   3 3-1/4   3-1/8   3 3-1/2   3-9/16   P269-0010   P269-0011   P269-0012   P269-0013   P269-0014   P269-0015   P269-0016   P269-0017   P269-0018   4-5/8   4-5/8   3-1/2   3-1/2   3-3/16   4-3/4   5-3/8   6-1/4   7-1/4   6-3/4   4-1/4   Plastic   WIDTH (in.)   HEIGTH (in.)   3-1/2   DEPTH (in.)   2-1/2   2-1/2   3 BASE   Solid---   Solid   Solid   Ring   Solid   Ring   Solid   Ring   STYLE   Clear-   Beige   Clear   Clear   Beige   Beige   Clear   Clear   Beige   Beige   Clear   Beige   PART NO.   P269-0001   P269-0002   3-7/8   3-7/8   5-1/4   5-1/4   5-1/4   5-1/4   6-3/8   6-3/8   6-3/8   6-3/8   8-1/4   8-1/4   3-1/2   4-5/8   4-5/8   4-5/8   4-5/8   3-1/2   3-1/2   3-1/2   P269-0003   P269-0004   P269-0005   P269-0006   3-1/4   3 3-1/4   3 3-1/4   3 3-1/4   3-1/2   3-1/2   Solid   Ring   Ring   3-1/2   5-3/8   5-3/8   P269-0007   P269-0008   Ring   206   Download from Www.Somanuals.com. All Manuals Search And Download.   MISCELLANEOUS PARTS   MISCELLANEOUS PARTS   ROOM AIR CONDITIONER SERVICE CORDS   • 1/4 IN. QUICK CON-   NECT TERMINALS ON   POWER LEADS   • • RING TERMINAL ON   GROUND WIRE   IVORY COLOR EXCEPT   51PC CORDS ARE   GRAY   P402   FIG. A   FIG. B   FIG. C   FIG. D   FIG. E   FIG. F   FIG. G   WIRE   GAUGE   14   LENGTH   (in.)   WIRE   GAGE   14   LENGTH   PART NO.   (in.)   FIGURE   AMPS VOLTS   PART NO.   FIGURE   AMPS VOLTS   A B 15   15   125   250   93   51SA400353   52SQ402334   51CM400964   60AA400094   82   66   82   52CQ400994   51CM400974   52CQ401004   E 20   30   250   250   14   14   12   66   60   113   12   12   G 20   125   D ROOM AIR CONDITIONER FILTER   The 51YA680001 polyure-   thane foam replacement   room air conditioner filter   measures 22-3/4 in. x   14-1/2 in. x 1/4 in. thick. It   can be trimmed to fit most   RAC’s in use today.   Part No.:   51YA680001S   P729   207   Download from Www.Somanuals.com. All Manuals Search And Download.   TEMPERATURE ACTUATED SWITCHES   CONTROL BULB   • • CONTROL BULB WELLS FOR USE WITH   TEMPERATURE CONTROLLERS   BUSHING INCLUDED   C D B A DIMENSIONS (in.)   FOR BULB   THREAD   PART NO.   DIA. (in.)   5/16   3/8   SIZE NPT   1/2-14   1/2-14   1/2-14   1/2-14   3/4-14   1/2-14   A 13.0   6.3   7.6   8.7   8.7   5.7   B C D .4   .4   .4   .7   .7   .7   11.5   5.0   5.8   4.2   4.2   4.2   1.2   .7   1.4   3.7   3.7   .7   HL79PZ001   30HH406102   HL79ZZ002   HL79MZ001   HL79MZ005   HL79MZ007   3/8   1/2   1/2   1/2   AQUASTAT CONTROLLERS   Part No. P672-L6006C   Part No. P672-L4006   • OPERATE IN RESPONSE TO   TEMPERATURE CHANGES IN   HYDRONIC HEATING SYSTEMS.   PROVIDES SPDT SWITCHING FOR   THREE-WIRE APPLICATIONS.   COMBINES CIRCULATOR CONTROL   WITH HIGH AND LOW LIMITS.   HORIZONTAL OR VERTICAL SURFACE   • TOTALLY ENCLOSED MICRO   SWITCH SNAP-ACTING SWITCHES   OPERATE ON TEMPERATURE RISE   TO SET POINT.   VISIBLE CONTROL POINT SCALE   AND EXTERNAL ADJUSTMENT   SCREW PERMIT EASY SETTING.   HORIZONTAL OR VERTICAL   INSERTION AND DIRECT OR WELL   IMMERSION OF SENSING ELEMENT.   • • • • • • MOUNTING.   VISIBLE CONTROL POINT SCALE AND   EXTERNAL ADJUSTMENT SCREW   PERMIT EASY SETTING.   P4320   Part No. P672-L7124U UNIVERSAL OIL ELECTRONIC AQUASTAT CONTROLLER   • PROVIDES ELECTRONIC TEMPERATURE SENSING IN A UL LIMIT-RATED CONTROL WITH A   SINGLE SENSING PROBE.   • • • CONTROLS CIRCULATOR, OIL BURNER, AND BOILER TEMPERATURE.   REPLACES THE L8124A, L8124C, L8148A CONTROLLERS.   THE L7124U HAS A CASE THAT CAN BE CONVERTED FOR EITHER HORIZONTAL OR   VERTICAL MOUNTING.   HONEYWELL   PART NO.   PART NO.   P672-L4006A   P672-L4006B   P672-L6006C   P672-L7124U   L4006A1009   L4006B1007   L6006C1018   L7124U1003   P4321   208   Download from Www.Somanuals.com. All Manuals Search And Download.   TEMPERATURE ACTUATED SWITCHES   SWITCHING RELAYS   Part No. P673-RA889A SWITCHING RELAY   (HYDRONIC)   Part No. P673-R8845A UNIVERSAL   SWITCHING RELAY (HYDRONIC)   • • • • HIGH LOAD SWITCHING RELAY.   TROUBLESHOOTING LED.   REPLACEABLE TRANSFORMER FUSE.   LONG LIFE DC RELAY DRIVE CONTROL   TECHNOLOGY.   RELAY FOR USE WITH EXTERNAL 24 VAC   OR 24 VDC SUPPLY, WITH LINE-VOLTAGE   CONTROL, OR WITH INTERNAL 24-V   TRANSFORMER SUPPLY.   • • • • • REPLACEABLE, SOCKETED RELAY.   TWO TROUBLESHOOTING LED’S.   PUSH-TO-TEST BUTTON.   REPLACEABLE TRANSFORMER FUSE.   LOW VOLTAGE CONTACTS FOR POWERPILE   APPLICATIONS.   RELAYS CAN BE USED WITH EXTERNAL   24-VAC OR 24-VDC SUPPLY, LINE-VOLTAGE   CONTROL, OR WITH INTERNAL 24-V   TRANSFORMER.   • • P4325   HONEYWELL   PART NO.   PART NO.   P673-RA889A   P673-R8845A   RA889A1001   R8845U1003   209   Download from Www.Somanuals.com. All Manuals Search And Download.   |