Watkins Hot Tub LAP User Manual

Owner’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
SAFETY INFORMATION  
WATER QUALITY AND MAINTENANCE  
Important Safety Instructions ..........................................................1  
General Information ........................................................................20  
Methods for Testing the Spa Water................................................20  
Hot Spot® Spa Water Maintenance Program................................21  
Spa Frog® Water Care System ......................................................23  
Spa Frog Cartridge Replacement Instructions..............................23  
Hot Spot Water Treatment Guide ..................................................24  
Following the Spa Frog Sanitizer Routine ....................................24  
Ozone ..............................................................................................26  
Common Water Chemistry Questions ..........................................27  
Water Terminology ..........................................................................28  
Important Spa Instructions ..............................................................3  
INSTALLATION INSTRUCTIONS  
Site Preparation ................................................................................3  
Outdoor Installation and Patio Installation ......................................4  
Deck Installation................................................................................4  
Indoor/Basement Installation............................................................4  
Spa Leveling Instructions ................................................................4  
Spa Cover Installation ......................................................................5  
ELECTRICAL INSTALLATION  
MAINTENANCE AND SPA CARE  
Selecting the Voltage for your Spa ..................................................5  
115-230 Volt Conversion ..................................................................5  
230 Volt Subpanel Wiring Instructions ............................................6  
Filter Maintenance ..........................................................................29  
Care of Spa Pillow ..........................................................................30  
Care of the Exterior ........................................................................30  
Care of the Spa Cover....................................................................31  
Wood Spa Cabinet ........................................................................31  
Simulated Wood Spa Cabinet (Optional) ......................................31  
Draining your Spa ..........................................................................31  
Non-Operation in Cold Climate......................................................32  
Winterizing your Spa ......................................................................32  
SPA SPECIFICATIONS & ILLUSTRATION  
La PalmaTM (Model LAP) ....................................................................7  
Mallorca® (Model MAL) ....................................................................8  
Sorrento® (Model SOR) ....................................................................9  
Trinidad® (Model TRI)......................................................................10  
OPERATING INSTRUCTIONS  
SERVICE INFORMATION  
Start-up and Refill Procedures ......................................................11  
Heating and Hydromassage Systems ..........................................12  
Safety Equipment............................................................................13  
Spa Control Panel ..........................................................................14  
Locking Features ............................................................................15  
General Information ........................................................................33  
GFCI and High Limit Thermostat ..................................................33  
Miscellaneous Service Information................................................33  
Acts Invalidating Warranty..............................................................34  
Disclaimers......................................................................................34  
Watkins Customer Service ............................................................34  
Troubleshooting ..............................................................................35  
JET MENUS  
La Palma (Model LAP) ....................................................................16  
Mallorca (Model MAL) ....................................................................17  
Sorrento (Model SOR) ....................................................................18  
Trindad (Model TRI..........................................................................19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INFORMATION  
IMPORTANT SAFETY INSTRUCTIONS  
READ AND FOLLOW ALL INSTRUCTIONS  
AVOIDING THE RISK TO CHILDREN  
WARNING:  
• RISK OF CHILD DROWNING. Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents,  
ensure that children cannot use a spa unless they are supervised at all times.  
To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.  
To reduce the risk of injury, lower water temperatures are recommended for young children. Children are especially sensitive to hot water.  
DO:  
• Make sure you always lock the child resistant locks after using the spa for your children’s safety. Every Hot Spot® Spa is equipped with a  
locking cover that meets the ASTM F1346-91 Standard for Safety Covers.  
Test the water temperature with your hand before allowing your child to enter the spa to be sure that it’s comfortable. Children are  
especially sensitive to hot water.  
• Remind children that wet surfaces can be very slippery. Make sure that the children are careful when entering or exiting  
the spa.  
DON’T:  
• Allow children to climb onto the spa cover.  
• Allow children to have unsupervised access to the spa.  
AVOIDING THE RISK OF ELECTROCUTION  
Risk of electrocution  
• Connect only to a grounded source.  
• Do not bury the power cord. A buried power cord may result in death or serious personal injury due to electrocution if direct burial-type  
cable is not used, or if improper digging occurs.  
• A ground terminal (pressure wire connector) is provided on the control box inside the unit to permit connection of a minimum No. 10 AWG  
(6mm2) solid copper bonding conductor between this point and any metal equipment, metal water pipe, metal enclosures of electrical  
equipment, or conduit within five feet (1.5 m) of the unit as needed to comply with local requirements.  
WARNING:  
To reduce the risk of electrical shock, replace a damaged cord immediately. Failure to do so may result in death or serious personal injury  
due to electrocution.  
Your spa is provided with a Ground Fault Circuit Interrupter for user and equipment protection. To ensure proper operation of this  
important safety device, test according to the following instructions per electrical configuration.  
Cord-Connected 115 volt, 15 and 20 amp models: The GFCI is located at the end of the power cord. Before each use, with the unit  
operating, push the TEST button. The unit should stop operating and the GFCI power indicator will go out. Wait 30 seconds and then  
reset the GFCI by pushing the RESET button. The GFCI power indicator will turn on, restoring power to the spa. If the interrupter does not  
perform in this manner, there may be an electrical malfunction and with it, the possibility of an electric shock. Disconnect the power until  
the problem has been corrected.  
230 volt, permanently installed or converted models:  
• A ground terminal is provided on the terminal block located inside the control box. To reduce the risk of electric shock, connect this  
terminal to the grounding terminal of your electrical service or supply panel with a continuous green, insulated copper wire. The wire must  
be equivalent in size to the circuit conductors supplying the equipment. In addition, a bonding terminal (pressure wire connector) is  
provided on the outside of the control box for bonding to local ground points. To reduce the risk of electric shock, this connector should  
be bonded with a No. 10 AWG solid copper wire to any metal ladders, water pipes, or other metal within 5 feet (1.5 m) of the spa to  
comply with local requirements. The means of disconnection must be readily accessible, but must be installed at least 5 feet (1.5 m) from the spa.  
Your spa is provided with a suitably rated circuit breaker to open all ungrounded supply conductors.  
Your spa uses ground fault circuit interrupters in the electrical subpanel. Before each use of the spa and with the unit operating, push the  
Test button on each breaker. The switch should click over to the “Trip” position. Wait 30 seconds and reset each GFCI breaker by  
switching it completely off and then completely on. The switch should then stay on. If either of the interrupters does not perform in this  
manner, it is an indication of an electrical malfunction and the possibility of an electric shock. Disconnect the power until the fault has been  
identified and corrected.  
Safety Information  
Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DANGER: RISK OF ELECTRICAL SHOCK  
• Install at least 5 feet (1.5 m) from all metal surfaces. A spa may be installed within 5 feet of a metal surface if each metal surface is  
permanently connected by a minimum No. 10 AWG (6mm2) solid copper conductor attached to the wire ground connector on the terminal  
box that is provided for this purpose if in accordance with National Electrical Code ANSI/NMFPA70-1993.  
• Do not permit any electrical appliances, such as a light, telephone, radio, or television within 5 feet (1.5 m) of a spa. Failure to maintain a  
safe distance may result in death or serious personal injury due to electrocution if the appliance should fall into the spa.  
DO:  
• Be sure your spa is connected to the power supply correctly - use a licensed contractor.  
• Disconnect the spa from the power supply before draining the spa or servicing the electrical components.  
Test the Ground Fault Circuit Interrupter(s) before each use.  
DON’T:  
• Use the spa with the equipment compartment door removed.  
• Place electrical appliances within 5 feet (1.5m) of the spa.  
• Use an extension cord to connect the spa to its power source. The cord may not be properly grounded and the connection is a shock  
hazard. An extension cord may cause a voltage drop, which will cause overheating of the jet pump motor and motor damage.  
• Attempt to open the electrical control box. There are no user serviceable parts inside.  
RISKS TO AVOID  
DANGER: RISK OF INJURY  
To reduce the risk of injury to persons, DO NOT remove suction fittings (filter standpipes) located in the filter compartment.  
• The suction fittings in the spa are sized to match the specific water flow created by the pump. Should the need arise to replace the  
suction fittings, or the pump, be sure that the flow rates are compatible.  
• There is a danger of slipping and falling. Remember that wet surfaces can be very slippery. Take care when entering or exiting the spa.  
• People with infectious diseases should not use the spa.  
• Keep any loose articles of clothing, long hair or hanging jewelry away from rotating jets or other moving components.  
Increased side effects of medication  
• The use of drugs, alcohol, or medication before or during spa use may lead to unconsciousness with the possibility of drowning.  
• Persons using medications should consult a physician before using a spa; some medication may cause a user to become drowsy, while  
other medication may affect heart rate, blood pressure, and circulation.  
• Persons taking medications that induce drowsiness, such as tranquilizers, antihistamines, or anticoagulants should not use the spa.  
Health problems affected by spa use  
• Pregnant women should consult a physician before using spa.  
• Persons suffering from obesity or with a medical history of heart disease, low or high blood pressure, circulatory system problems, or  
diabetes should consult a physician before using spa.  
Unclean water  
• Keep the water clean and sanitized with correct chemical care. The recommended levels for your Hot Spot® Spa are:  
Free Available Chlorine (FAC):  
Water pH:  
3.0-5.0 ppm  
7.4-7.6  
Total Alkalinity:  
Calcium Hardness:  
125-150 ppm  
150-200 ppm  
(Refer to Water Quality and Maintenance section for complete instructions.)  
IMPORTANT: Turn on the jet pump for a least ten minutes after adding ANY spa water chemicals into the filter compartment.  
• Clean the filter cartridge monthly to remove debris and mineral buildup which may affect the performance of the hydromassage jets, limit  
the flow, or trip the high limit thermostat which will turn off the entire spa.  
AVOIDING THE RISK OF HYPERTHERMIA  
Prolonged immersion in hot water can result in HYPERTHERMIA, a dangerous condition which occurs when the internal temperature of the body  
reaches a level above normal (98.6°F or 37°C). The symptoms of hyperthermia include unawareness of impending hazard, failure to perceive heat,  
failure to recognize the need to exit the spa, physical inability to exit the spa, fetal damage in pregnant women, and unconsciousness resulting in a  
danger of drowning.  
WARNING:  
The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.  
Page 2  
Safety Information  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO REDUCE THE RISK OF INJURY:  
• The water in the spa should never exceed 104°F (40°C) . Water temperatures between 100°F (38°C) and 104°F (40°C ) are considered safe  
for a healthy adult. Lower water temperatures are recommended for extended use (exceeding ten minutes) and for young children.  
Extended use can cause hyperthermia.  
• Pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C). Failure to do so may result in permanent injury  
to your baby.  
• Do not use spa immediately following strenuous exercise.  
AVOIDING THE RISK OF SKIN BURNS:  
WARNING:  
To reduce the risk of injury, before entering a spa the user should measure the water temperature with an accurate thermometer, since the  
tolerance of temperature-regulating devices may vary by as much as 5°F (3°C).  
Test the water with your hand before entering the spa to be sure it’s comfortable.  
SAFETY SIGN  
Each Hot Spot® Spa is shipped with a SAFETY SIGN in the owner’s package. The sign, which is required as a condition of Product Listing, should  
be permanently installed where it is visible to the users of the spa. To obtain additional SAFETY SIGNS, contact your Hot Spot dealer and request  
Part #003021.  
IMPORTANT SPA INSTRUCTIONS  
The following contains important spa information, and we strongly encourage you to read and apply them.  
DO:  
• Use and lock the cover when the spa is not in use, whether it is empty or full.  
• Follow the Spa Care and Maintenance recommendations stated in this manual.  
• Use only approved accessories and recommended spa chemicals and cleaners.  
DON’T:  
• Leave the Hot Spot Spa exposed to the sun without water or the cover in place. Exposure to direct sunlight can cause solar distress of the  
shell material.  
• Roll or slide the spa on its side. This will damage the siding.  
• Lift or drag the vinyl cover by using the cover lock straps; always lift or carry the cover by using the handles.  
• Attempt to open the electrical control box. There are no user serviceable parts inside. Opening of the control box by the spa owner will  
void the warranty. If you have an operational problem, carefully go through the steps outlined in the Troubleshooting section. If you are not  
able to resolve the problem, contact your authorized Hot Spot Spa Dealer. Many problems can easily be diagnosed over the telephone by  
an Authorized Service Technician.  
SAVE THESE INSTRUCTIONS  
INSTALLATION INSTRUCTIONS  
SITE PREPARATION  
You probably have a spot picked out for your new spa, whether it’s indoors or outdoors, on a patio or on a deck. Just make sure you check the  
following:  
• Always put your spa on a structurally sound, level surface. A filled spa can weigh a great deal. Make certain that the location you choose  
can support the weight of your filled spa.  
• Don’t forget to level your spa before filling it (see Spa Leveling Preparation on next page).  
• Locate your equipment compartment, which houses all of the electrical components, in a place where water will drain away from it.  
Allowing water into the equipment compartment can damage the electronics, or may result in tripping your house’s circuit breaker.  
• Leave yourself easy access to the Ground Fault Circuit Interrupter (GFCI) for testing. The GFCI is located at the end of the power cord, or  
at the subpanel of a hard-wired spa.  
• Never let water get into the subpanel or into the electrical outlet that your spa is plugged into. Consult your local code authority to  
determine if an electrical outlet with a cover is required for your installation.  
• Leave access to the equipment compartment for periodic spa care and maintenance.  
Safety Information  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING: Damage to the spa’s equipment compartment components or internal plumbing as a result of rodent infestation is NOT  
covered under your warranty!  
WARNING  
OUTDOOR AND PATIO INSTALLATION  
No matter where you install your new spa, it’s important that you have a solid foundation to support it.  
Structural damage to the spa, resulting from incorrect installation or placement on an inadequate foundation, is  
not covered under the spa’s limited warranty.  
If you install the spa outdoors, we recommend a reinforced concrete pad at least four inches thick. The  
reinforcing rod or mesh in the pad should be attached to a bond wire.  
Lowering the top of the spa  
to deck level substantially  
increases the potential of  
accidental entry. Contact  
DECK INSTALLATION  
To be certain your deck can support your spa, you must know the deck’s maximum load capacity. Consult a  
qualified building contractor or structural engineer. To find the weight of your spa, its contents and occupants,  
refer to the Spa Specifications chart on the back cover. This weight per square foot must not exceed the  
structure’s rated capacity, or serious structural damage could result.  
your Hot Spot Dealer for  
more information and  
consult a licensed building  
contractor to design or  
evaluate your custom  
decking requirements.  
INDOOR/BASEMENT INSTALLATION  
Be aware of some special requirements if you place your spa indoors. Water will accumulate around the spa, so  
flooring materials must provide a good grip when wet. Proper drainage is essential to prevent a build-up of water  
around the spa. When building a new room for the spa it is recommended that a floor drain be installed. The humidity will naturally increase with  
the spa installed indoors. Water may get into woodwork and produce dry rot, mildew, or other problems. Check for airborne moisture’s effects on  
exposed wood, paper, etc. in the room. To minimize these effects, it is best to provide plenty of ventilation to the spa area. An architect can help to  
determine if more ventilation must be installed.  
Your spa dealer can help you with local information such as zoning regulations and building codes.  
WARNING: Please keep the area around your spa well ventilated when it is installed indoors or in a confined area. Inadequate ventilation  
around the spa could cause a build-up of a higher-than-normal concentration of spa chemicals and/or bacterial fragments. These dispersed spa  
chemicals and/or bacterial fragments can be inhaled, and may result in breathing difficulties or lung damage in certain people suffering from a  
compromised immune system or respiratory infection. If you or other bathers are affected by this condition, please seek medical attention as soon as  
possible.  
In addition to the above, properly clean and maintain your spa as follows:  
• Follow all procedures in this owner’s manual and printed instructions on all water care (chemical) products packaging.  
Test the water regularly to ensure proper levels of sanitizers, pH, and other water care requirements.  
• Drain, clean, and refill your spa with fresh water on a regular schedule, and in accordance with this owner’s manual.  
• Clean the filter(s) at least once per month.  
• Check to make sure you have proper circulation throughout your spa water system.  
• Have spa users bathe before entering the spa water.  
SPA LEVELING PREPARATION  
Concrete sloped at 1/2 inch (1.3 cm) per 10 feet (305 cm) is preferred so that rain water and water spillover will run off and not puddle underneath  
the spa (water under the spa for long periods of time may cause the wood to deteriorate). Other options are brick, stepping stone, or blocks.  
It is important to note that soft surfaces, even when stepping stones are used to evenly distribute the weight of the spa, will have a tendency to  
settle, thus resulting in an unleveled spa.  
NOTE: Placing the spa on grass or dirt may increase the amount of debris which is inadvertently brought into the spa water and may cause harm  
to your equipment as well as the spa surface, which is not covered under warranty.  
1/2 inch  
(1.3 cm)  
10 ft. (305 cm)  
Slope 1/2 inch per 10 ft. for proper drainage.  
Stepping stones or brick may settle  
causing the spa to be unlevel.  
Page 4  
Installation Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPA COVER INSTALLATION  
• Place the cover squarely on the spa.  
• Position the tie-down locks included with your cover on the side of the spa so that they are easily reached by the cover tie-down straps.  
Allow for about 1/2” to 3/4” slack in the straps to make it easy to insert straps into locks and to compensate for vinyl shrinkage in cold weather.  
• Attach the locks with the screws provided and insert the cover tie-down straps into the locks.  
COVER INSTALLATION  
NOTE: Keeping the cover in place any time the spa is not in use will reduce the amount of time the  
heater operates, thereby minimizing operating costs.  
COVER  
TIE-DOWN STRAP  
DANGER. RISK OF INJURY.  
• Never leave a spa uncovered or unattended.  
• Never leave a spa cover unlocked.  
• Do not stand, sit, or lie on the cover.  
LOCK  
KEY  
SCREW (2)  
ELECTRICAL INSTALLATION  
SELECTING THE VOLTAGE FOR YOUR SPA  
Your spa is designed to operate at either 115 or 230 volts, 60 Hz, unless it is the Mallorca® or La PalmaTM models which requires a dedicated 230 volt  
power supply. When the spa is connected to 115 volts, the heater will provide approximately 1000 watts of heat only when the pump is operating in  
LOW speed and the thermostat is calling for heat. When the spa is connected to 230 volts, the heater will provide approximately 4000 watts of heat  
when the pump is operating in LOW or HIGH speed and the thermostat is calling for heat.  
All electrical connections must be made in accordance with the wiring information contained in the electrical control box or on the back of the field  
wiring access panel of the equipment module.  
115 VOLT INSTALLATION  
Spas provided with a factory- installed power supply cord are to be plugged into a grounded, grounding type, 115 volt, 20 ampere receptacle  
(Trinidad® and Sorrento® models). No other electrical appliance or fixture can be used on this circuit.  
IMPORTANT: Under NO circumstances should an extension cord be used. Use of an extension cord will seriously degrade the performance of the  
equipment module and can create an electrical hazard.  
230 VOLT INSTALLATION  
When using 230 volt power supply, installation of a 50 amp dedicated circuit is required. Your spa must be hardwired direct to a GFCI-protected  
subpanel by a licensed electrician. A wiring diagram is provided inside the equipment module showing where the connections are to be made.  
ELECTRICAL REQUIREMENTS AND PRECAUTIONS  
Your Hot Spot® spa has been carefully designed to give you maximum safety against electrical shock. Connecting the spa to an improperly wired  
circuit will negate many of the spa’s safety features. Improper wiring may also cause electrocution, risk of fire, and other risks of injuries. Please  
read and follow the electrical installation requirements and instructions for your spa completely!  
115-230 VOLT CONVERSION  
SORRENTO(ModelSOR)  
TRINIDAD(ModelTRI)  
Refer to the following instructions to convert your 115 volt Hot Spot spa to a 230 volt spa.  
NOTE: Converting the spa to 230 volts operation should only be done by an authorized service agent or a qualified electrician.  
The conversion requires a subpanel (230 volt) which may be purchased from your Authorized dealer. Ask for part # 38661.  
1. Disconnect the power cord from the house receptacle.  
2. Remove the screws and open the equipment compartment door.  
3. Remove the screws from the control box.  
4. Open the control box cover.  
5. Remove the power cord wires, and the power jumper wire (from line 2 and neutral) on the line side of the terminal block.  
6. Locate Program Jumper JMP 1, using a pair of needle nose pliers, carefully move the parked (spare) jumper onto JP1  
(see Figure on next page).  
A licensed electrician must install the subpanel (available from your dealer) to supply power to the spa. The subpanel must be placed in sight of the  
spa at a minimum distance of 5 (1.5 meters) feet away.  
Electrical Installation  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
230 VAC CONVERTED SPA  
230 Volt  
Converted  
Sorrento® &  
TERMINAL BLOCK  
POWER JUMPER  
REMOVE POWER JUMPER  
FROM TERMINAL BLOCK TO  
CONVERT SPA TO OPERATE  
Trinidad®  
Jumper  
NOTE: To change from Fahrenheit  
to Celsius remove jumper on JP2.  
SEE WIRING  
ILLUSTRATION  
AT 230 VAC.  
Configuration  
230 VAC PERMANENTLY CONNECTED SPA  
230 Volt  
Mallorca® &  
La Palma  
Spa Model  
Jumper  
NO POWER  
JUMPERS REQUIRED  
NOTE: To change from Fahrenheit  
to Celsius remove jumper on JP2.  
SEE WIRING  
ILLUSTRATION  
Configuration  
230 VOLT SUBPANEL WIRING INSTRUCTIONS  
NOTE: The subpanel must be placed within 100 feet of the main electrical service panel, and between 5 (1.5 m) and 50 feet (15 m) away from the  
spa. All electrical connections must be made in accordance with the wiring information contained in this manual and on the back of the field wiring  
access panel of the control box.  
Refer to the wiring diagram below.  
1. Connect the #8 AWG, WHITE [NEUTRAL] wire from the Neutral/Ground Bar on the main electrical service to the WHITE [NEUTRAL, Panel  
Neutral, Pigtail] of the subpanel.  
2. Connect the #8 AWG, BLACK [L1] wire from the main electrical service to the subpanel [terminal L1].  
3. Connect the #8 AWG, RED [L2] wire from the main electrical service to the subpanel [terminal L2].  
4. Connect the #8 AWG, GREEN wire from the Neutral/Ground Bar on the main electrical service to the GROUND terminal of the subpanel.  
5. Connect the #8 AWG, WHITE [NEUTRAL] wire from the subpanel breaker to the Neutral terminal on the spa’s control box.  
6. Connect the #8 AWG, BLACK [L1] wire from the subpanel breaker to terminal [L1] on the spa’s control box.  
7. Connect the #8 AWG, RED [L2] wire from the subpanel breaker to terminal [L2] on the spa’s control box.  
8. Connect the #8 AWG, GREEN wire from the GROUND terminal of the subpanel to the GROUND terminal in the spa’s control box.  
9. Bond the spa to all exposed metal equipment or fixtures, handrails, and concrete pad pre N.E.C. and all local codes.  
PERMANENTLY CONNECTED  
230VAC, 50 AMP  
230 VAC, 40A, 60Hz, MODELS  
2-POLE  
CIRCUIT BREAKER  
(NON GFCI)  
#8AWGWHITE,NEUTRAL  
N,NEUTRAL,#8AWGWHITE  
#8*AWGGREEN,GROUND  
L2,HOT,#8AWGRED  
#8AWGBLACK,L1  
L1,HOT,#8AWGBLACK  
#8AWGRED,L2  
GROUND,#8AWGGREEN*  
MAIN SERVICE  
ELECTRICAL  
SUB-PANEL  
PANEL  
LESS THAN 100 FT.  
WITH GFCI  
BREAKERS  
MORE THAN 5FEET  
THESUB-PANELMUSTBE  
WITHINSIGHTOFTHESPA  
DONOTEXCEED50FEET  
CONTROL BOX  
*ALL CANADIAN SPA MODELS USE #8 AWG GREEN, GROUND.  
THESE SPAS ARE INTENDED FOR USE WITH GFCI SUBPANEL PROVIDED.  
Page 6  
Electrical Installation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LA PALMATM (MODEL LAP)  
HORIZONTAL DIMENSIONS: . . . . . . . . . . . . .91” x 91” (231 cm. x 231 cm.)  
HEIGHT (without cover): . . . . . . . . . . . . . . . . . . .38” (97 cm.)  
EFFECTIVE FILTER AREA: . . . . . . . . . . . . . . . . .65 sq. ft. (6.0 sq. meters)  
HEATER: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4000 watts (4.0 kW) @ 230V  
WATER (capacity): . . . . . . . . . . . . . . . . . . . . . . .430 gallons (1628 liters)  
WEIGHT: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .961 lbs. dry (436 kg.), 5656 lbs. filled (2566 kg.)  
(Includes weight of water and 7 adults @ 175 lbs. each.)  
DEAD WEIGHT (filled): . . . . . . . . . . . . . . . . . . . . 110 lbs. per sq. ft., 555 kg. per sq. meter  
ELECTRICAL REQUIREMENTS: . . . . . . . . . . . .230 volt 50 amp single phase G.F.C.I. circuit  
NOTE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .All wiring must be performed by a licensed electrician.  
CERTIFICATIONS: . . . . . . . . . . . . . . . . . . . . . . .ETL Listed and TUV Certified  
OVERHEAD VIEW  
A
A
A. Air Control Lever  
N
N
B. Diverter Valve  
K
K
H
G
C. Control Panel  
H
D. Spa Light  
H
E. Filter Compartment Cover  
F. Temperature Sensor  
G. Precision® Jets  
I
A
A
H. Adjustable Hydromassage Jet  
I. Outlet for optional Ozone  
O
G
J. Drain  
J
H
K. Pillow  
G
G
L. Waterfall  
H
M. Waterfall On/Off Valve  
N. Stereo Speaker  
(Stereo Model Only)  
O. Stereo Wired Remote  
(Stereo Model Only)  
P. Spa Frog  
G
B
J
G
M
J
D
F
G
H
E
L
G
N
P
N
B
A
A
C
Spa Specifications & Illustration  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPA SPECIFICATIONS & ILLUSTRATION  
MALLORCA® (MODEL MAL)  
HORIZONTAL DIMENSIONS: . . . . . . . . . . . . .84” (213 cm.) square  
HEIGHT (without cover): . . . . . . . . . . . . . . . . . . .36” (91 cm.)  
EFFECTIVE FILTER AREA: . . . . . . . . . . . . . . . . .75 sq. ft. (6.97 sq. meters)  
HEATER: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4000 watts (4.0 kW)  
WATER (capacity): . . . . . . . . . . . . . . . . . . . . . . .360 gallons (1363 liters)  
WEIGHT: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .706 lbs. dry (320 kg.), 4636 lbs. filled (2103 kg.)  
(Includes weight of water and 6 adults @ 175 lbs. each.)  
DEAD WEIGHT (filled): . . . . . . . . . . . . . . . . . . . . 100 lbs. per sq. ft., 490 kg. per sq. meter  
ELECTRICAL REQUIREMENTS: . . . . . . . . . . . .230 volt 50 amp single phase G.F.C.I. circuit  
NOTE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .All wiring must be performed by a licensed electrician.  
CERTIFICATIONS: . . . . . . . . . . . . . . . . . . . . . . .ETL Listed and TUV Certified  
A
OVERHEAD VIEW  
A. Air Control Lever  
J
J
B. Control Panel  
F
F
G
C. Spa Light  
G
D. Filter Compartment Cover  
E. Temperature Sensor  
F. Directional Precision® Jets  
G. Adjustable Hydromassage Jet  
H. Outlet for optional Ozone  
I. Drain  
H
I
A
G
J. Pillow  
I
I
K. Waterfall  
L. Waterfall On/Off Valve  
M. Spa Frog  
C
K
F
F
G
J
D
E
L
B
M
A
A
Page 8  
Spa Specifications & Illustration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SORRENTO® (MODEL SOR)  
HORIZONTAL DIMENSIONS: . . . . . . . . . . . . .78” (198 cm.) square  
HEIGHT (without cover): . . . . . . . . . . . . . . . . . . .36” (91 cm.)  
EFFECTIVE FILTER AREA: . . . . . . . . . . . . . . . . .50 sq. ft. (4.65 sq. meters)  
HEATER: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000 watts (1.0 kW) @ 115V, 4000 watts (4.0 kW) @ 230V  
WATER (capacity): . . . . . . . . . . . . . . . . . . . . . . .280 gallons (1060 liters)  
WEIGHT: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .570 lbs. dry (259 kg.), 3510 lbs. filled (1592 kg.)  
(Includes weight of water and 4 adults @ 175 lbs. each.)  
DEAD WEIGHT (filled): . . . . . . . . . . . . . . . . . . . . 80 lbs. per sq. ft., 390 kg. per sq. meter  
ELECTRICAL REQUIREMENTS: . . . . . . . . . . . .115 volt 20 amp grounded circuit  
230 volt 50 amp single phase G.F.C.I. circuit  
NOTE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 volt wiring must be performed by a licensed electrician.  
CERTIFICATIONS: . . . . . . . . . . . . . . . . . . . . . . .ETL Listed and TUV Certified  
OVERHEAD VIEW  
A. Air Control Lever  
B. Control Panel  
C. Spa Light  
K
D. Filter Compartment Cover  
G
G
E. Temperature Sensor  
F. Directional Precision® Jets  
G. Adjustable Hydromassage Jet  
H. Diverter Valve  
I
G
I. Outlet for optional Ozone  
J. Drain  
K. Pillow  
L. Spa Frog  
A
E
L
J
F
C
F
D
K
A
H
B
Spa Specifications & Illustration  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TRINIDAD® (MODEL TRI)  
HORIZONTAL DIMENSIONS: . . . . . . . . . . . . .80” x 70” (203 cm. x 178 cm.)  
HEIGHT (without cover): . . . . . . . . . . . . . . . . . . .34” (86 cm.)  
EFFECTIVE FILTER AREA: . . . . . . . . . . . . . . . . .50 sq. ft. (4.65 sq. meters)  
HEATER: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000 watts (1.0 kW) @ 115V, 4000 watts (4.0 kW) @ 230V  
WATER (capacity): . . . . . . . . . . . . . . . . . . . . . . .290 gallons (1098 liters)  
WEIGHT: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .540 lbs. dry (245 kg.), 3735 lbs. filled (1694 kg.)  
(Includes weight of water and 5 adults @ 175 lbs. each.)  
DEAD WEIGHT (filled): . . . . . . . . . . . . . . . . . . . . 100 lbs. per sq. ft., 490 kg. per sq. meter  
ELECTRICAL REQUIREMENTS: . . . . . . . . . . . .115 volt 20 amp grounded circuit  
230 volt 50 amp single phase G.F.C.I. circuit  
NOTE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 volt wiring must be performed by a licensed electrician.  
CERTIFICATIONS: . . . . . . . . . . . . . . . . . . . . . . .ETL Listed and TUV Certified  
OVERHEAD VIEW  
A. Air Control Lever  
B. Control Panel  
C. Spa Light  
D. Filter Compartment Cover  
E. Temperature Sensor  
G
F
F
F. Precision® Jets  
G. Adjustable Hydromassage Jet  
H. Outlet for optional Ozone  
I. Drain  
G
J. Pillow  
F
G
K. Spa Frog  
F
H
G
I
G
F
J
D
E
C
B
K
A
A
Page 10  
Spa Specifications & Illustration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
START-UP AND REFILL PROCEDURES  
Your Hot Spot® spa has been thoroughly tested during the manufacturing process to ensure reliability and long-term customer satisfaction. A  
small amount of water may have remained in the plumbing after testing and, as a result, may have spotted the spa shell or the spa siding prior to  
delivery. Before filling the spa, wipe the spa shell clean with a soft rag.  
The following instructions must be read and followed exactly to ensure a successful start-up or refill.  
CAUTIONS  
Do not fill the spa with hot water, as tripping of the high-limit thermostat may result.  
DO NOT CONNECT POWERTO AN EMPTY SPA. Power to the spa automatically activates critical components within the spa,  
such as controls, heater, and other systems. If power is supplied to these components prior to the spa being filled, the  
components will be damaged, and this may result in a non-warranty component failure.  
Do not use your spa after filling until all of the steps listed below are completed.  
Do not add chlorine if treating your spa with polyhexamethylene biguanide (Biguanide, PHMB, eg. BaquaSpa®) sanitizer.  
Before filling your spa for the first time, remove the equipment compartment door and check to ensure that the unions on either  
side of the pump(s) and heater are hand-tight.  
1. Ensure the drain is closed and remove the filter compartment cover, skimmer basket, weir, and filter. Then insert the end of a garden hose into  
the filter hole and begin filling the spa. The water level of your Hot Spot spa should be maintained at a level one inch above the highest jet in  
the spa. Reinstall the skimmer basket, weir, and filter once the spa is filled.  
IMPORTANT: Watkins Manufacturing Corporation does not recommend that the spa be filled with “softened” water, as this may damage the  
spa’s equipment.  
2. Install SPA FROG bromine and mineral cartridges. See Spa Frog Replacement Instruction section and install the cartridge.  
IMPORTANT: Each time the spa is filled with water, you must remove and reinstall the SPA FROG cap, even if you are not replacing  
the cartridge, in order to properly prime the jet pumps.  
3. AFTER the spa has been filled with water and the equipment compartment door is secured, power must be applied to the spa.  
115 volt models: Connect the GFCI to the waterproof receptacle and push the RESET button on the GFCI.  
230 volt models: Open the door of the electrical subpanel and reset the GFCI breaker. Close and secure the subpanel door.  
4. The jet pump(s), heating system and all internal plumbing will achieve a partial prime as the spa is filled. To check the operation of the jet  
system and to purge any remaining air from the heating system, push the JETS button on the control pad twice (three times for Mallorca®) to  
make the jet pump(s) run on high speed for one minute. Once the jet system is fully operational (as indicated by strong, non-surging jets),  
priming of the spa is complete. If you do not feel a steady stream of water from your jets, refer to the instructions for priming the pump in the  
SPA TROUBLESHOOTING section in the back of this manual.  
5. Adjust Total Alkalinity (TA) to 125 ppm, Calcium Hardness (CH) to 150 ppm, then spa water pH to between 7.4 and 7.6. These procedures are  
listed in the “Water Quality and Maintenance” section.  
IMPORTANT: Add spa water chemicals directly into the filter compartment after activating “Clean Cycle” (Press SET, then Jets button).  
OPERATION NOTES:  
1. Your spa is equipped with a ten-minute timer delay on the heating/maintenance mode. Whenever the jet pump has been turned off (and a  
three-degree temperature drop has occurred) or the temperature control has been turned up, it will take ten minutes before the low speed of  
the jet pump and heater become activated. Always push the JETS button to turn off the jet pump when exiting the spa. In the standard 115  
volt, 20 amp electrical configuration, the heating system does not operate simultaneously with the high speed pump. On the other hand, on  
the 230 volt system, the heating system does operate simultaneously with the high speed pump.  
2. The spa controller has an automatic two hour “time-out” feature should the high speed jet mode be left on inadvertently. After one hour of  
continuous operation, the controller will automatically return to the maintenance/heating mode.  
3. The spa controller also has a six-hour “time-out” feature should the light be left on inadvertently. After six hours of continuous operation,  
the controller will automatically turn the light off.  
Operating Instructions  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HEATING AND HYDROMASSAGE SYSTEMS  
The Hot Spot® Spa uses a two-speed jet pump to operate its hydromassage jets and to circulate the spa water through the heating system (the  
Mallorca® & La PalmaTM are also equipped with a single speed jet pump used for jets only). The low speed mode of the pump, which is activated  
automatically by the control thermostat, will cause the spa water to be drawn slowly in through the filter, the heater, and into the pump. The  
pump, in turn, will push the water back into the spa through the jets. When the JETS button is pushed one time, the spa user can activate the  
low speed of the jet pump. (The heater may or may not be on, depending on whether the control thermostat has indicated a demand for heat.)  
When the JETS button is pushed a second time, the high speed of the jet pump will be activated. (This will automatically deactivate the heater if  
it is operating in a standard 115 volt 20 amp system.)  
In the 230 vollt electrical system, if a drop in the water temperature has occurred, the spa heater will operate simultaneously when the jet pump  
is operating on high speed. On the other hand, in a standard 115 volt 20 amp electrical system, the spa heater will not operate simultaneously  
when the jet pump is operating on high speed, even if a drop in the water temperature has occurred. In either electrical configuration, when the  
high speed mode of the jet pump is turned off, the spa will enter a ten-minute “tranquil mode.” During this time the heating system (and  
simultaneous operation of the jet pump at low speed) will not operate (unless the JETS button is pushed), even if the water temperature has  
dropped below the control setting. Once the ten-minute period has expired, the spa controller will switch to the maintenance mode and the  
heating system will be automatically activated.  
The Hot Spot Spa is equipped with a state-of-the-art heating system. The system uses an exclusive “flow through” No-Fault® stainless steel heater.  
HYDROMASSAGE JETS  
The larger jets in your spa allow you to re-direct the jet stream by changing the position of the nozzle.  
The Air Control lever is used to change the air intensity of all jets simultaneously.  
You can also regulate the force of the massage by rotating the jet face clockwise to reduce the force or counter-clockwise to increase the force.  
Notice that turning off the flow to some jets increases the flow to the other jets. To avoid damage to your spa’s plumbing and components, do  
not turn off more than half of these jets at the same time.  
Directional nozzles come standard on the Hot Spot models, however, a dual port rotary nozzle can be placed in any jet location desired. The  
directional nozzles can be removed by rotating the tabs to either side of the nozzle then grasping the nozzle and gently pulling away from the jet  
faceplate.  
ACCESSORY NOTE: dual port rotating nozzles are available from your Hot Spot dealer to replace the directional adjustable nozzles.  
®
PRECISION JETS  
Precision jets are small. They are designed to perform a soft, soothing massage on your back and shoulders. Adjust their pressure using the Air  
Control lever.  
AIR CONTROL SYSTEM  
AIR CONTROL VALVE: Turning the Air Control lever to the left position allows for the same volume of air to flow to all individual jets and Precision  
jets simultaneously. The jet faceplate on the larger jets is then used to control the water intensity of each hydromassage jet.  
NOTE: Always turn the Air Control lever to the right position anytime the spa is not being used. This will help make the spa operate more quietly  
and heat more efficiently when the vinyl cover is in place.  
DIVERTER VALVE (LA PALMA & SORRENTO® MODEL ONLY)  
TM  
The diverter valve on your spa allows you to direct the flow of water from the pump to several combinations of jets. The functions of this diverter  
valve can best be learned by experimentation as follows:  
1. Set all air controls to the “ON” position by rotating counterclockwise.  
2. Turn on the pump.  
3. Turn the handle on the diverter valve and see which groups of jets are affected. (Note that you can adjust the diverter valve to any position  
between the two possible extremes to achieve the jet pressure that feels best to you.)  
IMPORTANT: Your spa is not designed to provide full power to all jets when the diverter valve is in the “mid” position.  
Page 12  
Operating Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY EQUIPMENT  
A. GFCI: The Ground Fault Circuit Interrupter, located on the end of the power cord (115 Volt models only), is a safety device that is designed to  
sense as little as 5 milliamps of electrical current leakage to ground. It is very important to protect a GFCI from rain and other moisture.  
Watkins Manufacturing Corporation recommends that the GFCI be tested before each use to ensure it is functioning correctly.  
To test the GFCI:  
Cord-Connected 115Volt, 20 Amp Models: Before each use, with the spa operating, push the TEST button (located on the front of the  
GFCI). The GFCI breaker should trip to the “off” position, disconnecting power to the spa. Reset the GFCI by pushing the RESET button. The  
spa will now operate normally. If the interrupter does not perform in this manner, it is an indication of an electrical malfunction and the  
possibility of an electric shock. Unplug the spa until the fault has been identified and corrected.  
230Volt, Permanently installed or converted Models: The GFCI breaker is located inside the subpanel, before each use of the spa and  
with the unit operating, push the Test button on each breaker. The switch should click over to the “Trip” position. Wait 30 seconds and reset  
each GFCI breaker by switching it completely off and then completely on. The switch should then stay on.  
B. HEATER HIGH-LIMIT SWITCH: The heater high-limit sensor is located on the heater assembly. If for any reason the internal temperature of the  
heater exceeds 120°F (49°C), the high-limit circuit will trip and turn off the spa. The control panel display will display - - - -. The heater high-  
limit may be reset when the water temperature within the heater has cooled to approximately 110°F (43°C). Reset the heater high-limit by  
simply disconnecting power to the spa for thirty seconds. The cause of the overheating must be located to prevent a recurrence. The most  
common cause of limit-tripping is inadequate water flow through the heating system. This may be caused by an obstruction within the pump  
water lines (filter, pump intakes or internal plumbing), the non-function of the low-speed mode of the jet pump, or the malfunction of the  
control thermostat. Once the cause has been identified and corrected, and the sensor has cooled, reset spa by simply disconnecting power to  
the spa for thirty seconds.  
C. PRESSURE SWITCH: The pressure switch is located inside the control box on the heater, and is designed to prevent heater operation during  
a no or low flow condition. If for any reason flow through the heater is reduced or stopped, the pressure switch will trip. If the pressure switch  
_ . _ . _ . _  
has detected a no or low flow condition _ . _ . _ . _ will display. The most common causes of inadequate heater flow are a dirty or clogged  
_ _ _ _  
filter, obstruction in the plumbing lines, and non-operation of the low speed heat pump. Additionally, the control panel will display _ _ _ _ if  
the pressure switch senses flow through the heater when the jet pump is not activated. Contact your Authorized Service Technician if displayed.  
D. CONTROL THERMOSTAT: The control thermostat helps regulate the temperature of the water. If for any reason something were to happen to  
this device, the READY icon on the control panel will flash. Contact your Authorized Service Technician.  
Filter Cycle 1  
Icon  
Temp / Lock  
Display  
SPA CONTROL PANEL  
Your control panel consists of an LED display and convenient touch  
pads that allow you to set the water temperature and adjust the  
skim/filter cycle settings, lock spa temp, lock entire spa functions, as  
well as control the hydrotherapy jets, and light from spa-side.  
Sleep  
Icon  
Set Icon  
Temp  
Ready  
Icon  
Jets Button  
Temperature Up  
LED DISPLAY  
The LED display on your spa-side control panel continually shows the  
spa’s set water temperature. In certain situations, it will also display  
other messages. See TROUBLESHOOTING section.  
SET BUTTON  
Use the set button to control clean cycle, filter cycle, locking and light  
functions. To activate the desired mode, press the “SET” button. When  
the “SET” icon flashes push the applicable button. The “SET” mode  
ends after 3 seconds or when the “SET” icon stops flashing.  
Filter Cycle Icon  
Temperature Down  
Light Icon  
Filter Cycle 2  
Icon  
Light Button  
Set Button  
Jet Icon  
TEMPERATURE CONTROL  
The set temperature range is from 80°F (27°C) to 104°F (40°C). Temperatures of any setting may rise slightly depending on the current use and  
condition of your spa, and on outside temperature. Whenever power is disconnected and then reconnected to the  
READY  
spa, the water temperature setting will automatically return to the last temperature entered into the program.  
Pressing the Temp Up () button displays the spa’s set temperature. To increase the set temperature, press the Temp  
Up () button again, once for each degree of increased temperature desired. If you hold the button down, the set  
temperature will increase by one degree every half second.  
Pressing the Temp down () button displays the spa’s set temperature. To decrease the set temperature, press the Temp down () button again,  
once for each degree of decreased temperature desired. If you hold the button down, the set temperature will decrease by one degree every half second.  
JET PUMP CONTROL  
Pressing the Jet button changes the jet pump functions, depending on the number of presses:  
Operating Instructions  
Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TM  
La Palma & Mallorca® Spas only:  
1st press:  
2nd press:  
3rd press:  
4th press:  
5th press:  
Two-speed jet pump runs on low speed  
Two-speed jet pump runs on high speed  
One and Two-speed jet pumps run on high speed  
One-speed jet pump runs on high speed  
Both jet pumps are off.  
READY  
Sorrento® & Trinidad® Spas only:  
1st press:  
2nd press:  
3rd press:  
Two-speed jet pump runs on low speed  
Two-speed jet pump runs on high speed  
Jet pump off  
During filter cycles or when the thermostat is calling for heat, the pump’s low speed operates automatically and cannot be turned off by  
pressing the Temp Up () or Temp Down () touch pad.  
The pump on high speed automatically turns off after operating for two hours. The pump on low speed automatically turns off after operating  
for two hours.  
When the jets are active, the JETS Icon on the control panel will illuminate.  
LIGHT CONTROL  
Your Hot Spot® spa is equipped with a blue LED spa light. Press the LIGHT button to turn it on. The light automatically  
turns off after six hours. When the light is active, the LIGHT Icon on the control panel will illuminate. Press it a second  
time to turn the light to a medium light intensity, a third time for a low light intensity and a fourth time will turn it off. For  
enhanced spa enjoyment, an optional six color wheel light feature is available to create your desired ambience.  
READY  
SPLENDORS® LED LIGHTING (OPTIONAL)  
The Splendors LED lighting system allows you to brighten up your spa experience through different multi-colored lights: red, blue, white, purple,  
amber, and aqua. You can choose one stationary color or you can cycle through all the colors with the automatic color wheel.  
To install Splendors LED lights, you will need to contact your Hot Spot Dealer.  
To activate, press the SET button followed by the LIGHT button. To select a specific color, push the LIGHT button (within 5 seconds) while the  
desired color is displayed. If 5 seconds have passed, after color wheel activation, you will need to press SET followed by the LIGHT button to  
select a specific color. The Splendors LED lighting option is a great way to personalize your spa experience.  
FILTER CYCLES  
When the spa is first powered up, the automatic filter cycle will wait 10 minutes before starting. Your spa will  
SET  
READY  
automatically turn the first filter cycle on for 60 minutes on low speed. The second filter cycle will activate for 30  
minutes, 12 hours later. The filter cycle icon, F1 or F2 will be displayed in the control panel.  
NOTE: The optional FreshWater® III ozone system only works during the filter cycle.  
F1  
F2  
To modify the length of either filter cycle:  
A. Press and hold the SET button for approximately three seconds.  
B. Press the LIGHT button to select filter cycle 1 or 2 (F1 or F2 will be displayed).  
C. Using the Temp Up () or the Temp Down () button, adjust the value as desired, from 0 to 6 hours.  
D. After program is entered it will take10 seconds to save. Once saved, the display will then revert back to Temperature display.  
The filter cycle will activate the jet pump on low speed for the entire cycle. When activated, the filter cycle Icon on the  
display is turned on. If the temperature exceeds the set point by three degrees F for more than three hours, the  
READY  
system will cancel the FILTER cycle and the filter Icon will blink for the remaining filter cycle time. Should the  
F1  
temperature cool down to 1.5 degrees F below the set point before the end of the cycle, the cycle will resume for the  
rest of the time. Should you use the spa during the filter cycle by placing the jet pump on high speed, the FILTER Icon  
will blink. Once the jet pump has been shut off, a ten minute tranquil mode begins (FILTER Icon will be blinking during  
tranquil mode) before the filter cycle will resume. The blinking filter Icon indicates that the filter cycle timer is still counting, but the cycle has been  
temporarily interrupted.  
CLEAN CYCLE  
The Clean Cycle has been provided as a convenient timer for water maintenance. When the Clean Cycle is initiated,  
the Jet pump will activate in high speed. The jet pump icons will flash on and off until the cleaning cycle is complete.  
The total cleaning cycle time is ten minutes. If the clean cycle does not engage, make sure the SPA LOCK is  
deactivated. To activate the Clean Cycle, press the SET button followed by the JETS button.  
Page 14  
Operating Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SLEEP MODE  
The Sleep Mode operation is a feature that minimizes pump operation during quiet evening hours. For example, if  
Filter Cycle 1 (F1) is set to activate at 8:00 a.m., by default, Filter Cycle 2 (F2) will activate at 8:00 p.m. (12 hours later).  
During 8:00 p.m. to 8:00 a.m., if the spa should call for heat, the pump and heater will activate to heat the spa under  
normal temperature demand. However, when in Sleep Mode, should the spa call for heat, the pump and heater will  
be suspended after Filter Cycle 2 (F2) until the activation of Filter Cycle 1 (F1), at 8:00 a.m. to minimize pump  
READY  
activation during quiet evening hours.  
Important: Power-up of the spa starts the F1 sequence. In order for the sleep mode to work in the evening hours, the spa must be powered up in  
the early morning hours. The Sleep Mode will always be active the 6-12 hours between the end of (F2) and the begining of (F1) depending on how  
the filter cycle program is set.  
Note: If temperature drops below 80 degrees, heater will automatically activate to prevent spa from freezing.  
To activate Sleep Mode feature, press and hold Temp Up () & Temp Down () buttons together for 3 seconds. This will activate the feature and  
override the normal temperature demand. When these buttons have been engaged, a Moon & Stars icon (Sleep Icon) will appear in the display of  
the control panel, indicating this feature has been activated. To deactivate this feature, simply press and hold Temp Up () & Temp Down ()  
buttons together for 3 seconds once again.  
LOCKING FEATURES  
The locking features, TEMPERATURE LOCK and SPA LOCK, are enabled from the control panel by a specific combination of buttons. Once  
enabled, a lock will remain active until the specific button combination is applied to disable the lock. Even if power is disconnected from the spa  
and soon thereafter reapplied (such as a power outage), the lock will remain in place.  
SPA LOCK  
The Spa Lock feature deactivates all of the functions of the control panel. It is generally used to prevent unwanted  
use of the spa.  
READY  
To activate the Spa Lock, press SET button. When the SET icon flashes press the Temp Down () button. Do not  
press any other button on the control panel until the SET icon stops flashing. SLOC is then displayed.  
To deactivate the Spa Lock, press SET button. When the SET icon flashes press Temp Down () button. Do not  
press any other button on the control panel until the SET icon stops flashing. The SLOC is no longer displayed.  
TEMPERATURE LOCK  
The Temperature Lock feature deactivates the temperature control function from the control panel. All other functions  
READY  
on the control panel will operate normally. Temperature Lock is most often used by those who do not want others to  
change the set temperature of the spa water.  
To activate the Temperature Lock, press SET button. When the SET icon flashes press the Temp Up () button. Do  
not press any other button on the control panel until the SET icon stops flashing. TLOC is then displayed.  
To deactivate the Temperature Lock, press SET button. When the SET icon flashes press the Temp Up () button. Do not press any other button  
on the control panel until the SET icon stops flashing. TLOC is no longer displayed.  
MUSIC SOUND SYSTEM  
The La PalmaTM music spa comes equipped with a music system and includes the following:  
JBL Stereo  
Four Bartop Speakers  
Bartop Stereo Control Panel Mode Button  
NOTE: The operating instructions for the CD AM/FM Stereo have been included in the spa’s Owner’s Packet.  
STEREO CONTROL PANEL MODE BUTTON  
Press “  
” to turn stereo on and off  
Press “BAND” button - to switch between FM1,2,3 and AM.  
Press “MODE” button - to source between CD/AM/FM/CD Changer.  
Press “VOL  
” button - to increase volume.  
Press “VOL ” button - to decrease volume.  
Press “TRACK  
Press “TRACK  
or ” button - to advance to the next track (in CD mode).  
or ” button - to advance to the next available station (in radio mode).  
Operating Instructions  
Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TM  
LA PALMA (MODEL LAP) JET SYSTEM MENU  
JET PUMP 1 JET SYSTEM 1  
JET PUMP 1 JET SYSTEM 2  
6 Directional Precision Jets on front left wall.  
3 Adjustable Hydromassage Jet on back wall.  
1 Adjustable Hydromassage Jet on right back wall.  
6 Directional Precision® Jets on front left wall.  
1 Adjustable Hydromassage Jet on left wall.  
6 Adjustable Hydromassage Jet on back left wall.  
JET PUMP 2 JET SYSTEM 2  
JET PUMP 2 JET SYSTEM 1  
3 Adjustable Hydromassage Jet on right wall.  
1 Adjustable Hydromassage Jet on left front wall.  
4 Directional PrecisionJets on left front wall.  
8 Directional Precision Jets in footwell.  
1 Water Feature  
15 Directional Precision Jets on right back wall.  
1 Adjustable Hydromassage Jet on left front wall.  
4 Directional PrecisionJets on left front wall.  
1 Water Feature  
Page 16  
Jet Menu  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MALLORCA® (MODEL MAL) JET SYSTEM MENU  
JET PUMP 1  
8 Directional Precision® Jets on back  
left wall.  
1 Adjustable Hydromassage Jet on  
back wall.  
4 Directional Precision Jets on back  
right wall.  
2 Adjustable Hydromassage Jet on  
back right wall.  
Water feature  
JET PUMP 2  
2 Adjustable Hydromassage Jet on left  
wall.  
6 Directional Precision Jets in footwell  
3 Adjustable Hydromassage Jets in  
lounge.  
2 Directional Precision Jets in lounge  
Jet Menu  
Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SORRENTO® (MODEL SOR) JET SYSTEM MENU  
JET SYSTEM 1  
2 Adjustable Hydromassage Jet on  
right back wall.  
8 Directional Precision® Jets on back  
right wall.  
JET SYSTEM 2  
2 Adjustable Hydromassage Jet on left  
back wall.  
4 Directional Precision Jets in footwell  
2 Adjustable Hydromassage Jet on left wall.  
Page 18  
Jet Menu  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TRINIDAD® (MODEL TRI) JET SYSTEM MENU  
JET SYSTEM  
6 Directional Precision® Jets on back left wall.  
1 Adjustable Hydromassage Jet and 2 Directional  
Precision Jets on back wall.  
1 Adjustable Hydromassage Jet on back right wall  
4 Directional Precision Jets in footwell.  
1 Adjustable Hydromassage and 2 Directional Precision  
Jets on front right wall.  
1 Adjustable Hydromassage Jet on front wall.  
1 Adjustable Hydromassage Jet in lounge.  
Jet Menu  
Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER QUALITY AND MAINTENANCE  
Its important to have clean water. Water maintenance is one of the least understood, yet most important areas of spa ownership. Your dealer can  
guide you through the process of achieving and maintaining perfect water in your spa, given your local conditions. Your program will depend on  
your water’s mineral content, how often you use your spa, and how many people use it.  
®
+
Watkins recommends that you either use an entirely chlorine-based system, or an alternative system which uses silver ions (the FreshWaterAg  
silver ion purifier). Watkins recommends the use of Hot Spring® FreshWater® products. These are available from authorized Hot Spot® dealers.  
GENERAL INFORMATION  
THE THREE FUNDAMENTAL AREAS OF WATER MAINTENANCE:  
• Water Filtration  
• Chemical Balance/pH Control  
• Water Sanitation  
Water Sanitation is the responsibility of the spa owner, achieved through the regular and periodic (daily, if necessary) addition of an approved  
sanitizer. The sanitizer will chemically control the bacteria and viruses present in the fill water or introduced during use of the spa. Bacteria and  
viruses can grow quickly in undersanitized spa water.  
The water’s chemical balance and pH control are also the responsibility of the spa owner. You’ll have to add chemicals to maintain proper levels of  
Total Alkalinity (TA), Calcium Hardness (CH) and pH. Proper water balance and pH control will minimize scale buildup, extend the life of the spa,  
and allow the sanitizer to work at top efficiency.  
METHODS FOR TESTING THE SPA WATER  
Accurate water testing and analysis is an important part of effectively managing your spa water. You must have the ability to test for:  
Total Alkalinity (TA)  
• Calcium Hardness (CH)  
pH  
Sanitizer  
Two types of testing methods are recognized and recommended by Watkins:  
The ReagentTest Kit is a method which provides a high level of accuracy. The reagents come in either liquid or tablet form.  
Test Strips are a convenient testing method used by many spa owners. Keep in mind that test strips are susceptible to heat and moisture  
contamination, which will result in inaccurate readings.  
IMPORTANT: Always read and carefully follow the directions included with the Test Kit or Test Strips to ensure the accuracy of the test results.  
BASIC CHEMICAL SAFETY  
When using chemicals, read the labels carefully and follow directions precisely. Though chemicals protect you and your spa when used correctly,  
they can be hazardous in concentrated form. Always observe the following guidelines:  
• Allow only a responsible person to handle spa chemicals. Keep them out of the reach of children.  
• Accurately measure the exact quantities specified, never more. Do not overdose your spa.  
• Handle all containers with care. Store in a cool, dry, well ventilated place.  
• Always keep chemical containers closed when not in use. Replace caps on their proper containers.  
• Don’t inhale fumes or allow chemicals to come in contact with your eyes, nose, or mouth. Wash your hands immediately after use.  
• Follow the emergency advice on the product label in case of accidental contact, or if the chemical is swallowed. Call a doctor or the local  
Poison Control Center. If a doctor is needed, take the product container along so that the substance can be identified.  
• Don’t let chemicals get on surrounding surfaces or landscaping.  
• Don’t use a vacuum cleaner to clean up chemical spills.  
• Never smoke around chemicals. Some fumes can be highly flammable.  
• Don’t store any chemicals in the spa equipment compartment.  
HOW TO ADD CHEMICALS TO THE WATER  
®
IMPORTANT: All spa water chemicals (other than Spa Frog cartridges), including MPS+ (shock), chlorine, granulated pH increaser or decreaser,  
granulated total alkalinity increaser, calcium hardness increaser, liquid stain and scale inhibitor, and liquid defoamer must always be added directly  
into the filter compartment while the jet pump is running in high speed mode, and it must run for a minimum of ten minutes.  
Page 20  
Water Quality and Maintenance  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To Administer Spa Water Chemicals:  
1. Fold back the cover. Carefully remove and set aside the filter compartment cover (Trinidad® does not have a filter cover).  
2. Push the JET button twice to activate the jet pump’s high speed mode.  
3. Carefully measure the recommended amount of chemical and slowly pour it into the filter compartment. Use care not to splash chemicals on  
your hands, in your eyes, on the spa shell surface or on the siding.  
4. After ten minutes, shut off the jet pump and close and lock the cover to complete the procedure. Risk of Drowning: Never leave an open spa  
unattended!  
WARNING: High sanitizer levels can cause discomfort to the user’s eyes, lungs and skin. Always allow the sanitizer level to fall to the  
recommended range before using the spa.  
IMPORTANTSUPER CHLORINATION/NON-CHLORINE SHOCKTREATMENTNOTE: After administering a super chlorination treatment or non-  
chlorine shock to your spa, leave the cover open for a minimum of twenty minutes to allow the oxidizer gas to vent. A high concentration of trapped  
oxidizer gas which may exist as a result of the shock treatment (not daily sanitation) may eventually cause discoloration or vinyl degradation to the  
bottom of the cover. This type of damage is considered chemical abuse and is not covered under the terms of the limited warranty.  
!
THE HOT SPOT SPA WATER MAINTENANCE PROGRAM  
Each step in your water maintenance program is dependent on the completion of the previous steps. Omitting a step or failing to reach the  
recommended range may cause an imbalance in your water’s chemistry. Unbalanced water chemistry can damage the spa and its components as  
well as cause discomfort for the user.  
FILLING THE SPA WITH WATER  
®
A. To prevent contaminants from entering the spa, Watkins Manufacturing Corporation recommends using the FreshStart 10,000 pre-filter when  
filling the spa with water. Always fill the spa through the filter compartment.  
®
WARNING: DO NOT use the FreshStart10,000 pre-filter if you plan to use granular bromine or BaquaSpa as your sanitizer.  
B. The FreshStart10,000 pre-filter is designed to remove unwanted contaminants such as rust, dirt, detergents and algae from the fill water.  
Dissolved minerals and metals such as lead, calcium, copper and iron are not removed.  
C. Instructions are included with the FreshStart10,000 pre-filter. When the spa is filled, proceed to the Start-Up and Refill Procedures on page 11.  
BALANCING THE TOTAL ALKALINITY (TA)  
A. The recommended Total Alkalinity (TA) for your spa water is 125-150 ppm.  
B. Total Alkalinity is a measure of the total levels of carbonates, bicarbonates, hydroxides, and other alkaline substances in the water. TA is  
referred to as the water’s “pH buffer”. In other words, it’s a measure of the ability of the water to resist changes in pH level.  
C. If the TA is too low, the pH level will fluctuate widely from high to low. Fluctuations in pH can cause corrosion or scaling of the spa  
®
®
components. LowTA can be corrected by adding Hot Spring FreshWater pH/Alkalinity Up or sodium hydrogen carbonate.  
D. If the Total Alkalinity is too high, the pH level will tend to be high and may be difficult to bring down. It can be lowered by adding Hot Spring  
FreshWater pH/Alkalinity Down or sodium bisulfate.  
E. Once the TA is balanced, it normally remains stable, although the addition of more water with a high or low alkalinity will raise or lower the TA  
reading of the water.  
F. When the Total Alkalinity is within the recommended range, proceed to the next step.  
BALANCING THE CALCIUM HARDNESS (CH)  
A. The recommended Calcium Hardness (CH) level for your spa is 150-200 ppm.  
B. Calcium Hardness is a measure of the total amount of dissolved calcium in the water. Calcium helps control the corrosive nature of the spa’s  
water. That’s why calcium-low water (commonly known as “soft” water) is not recommended. It is very corrosive to the equipment, and can  
cause staining of the spa shell. If the calcium level is too low, we recommend using HotSpring FreshWater Calcium Increaser to bring the  
calcium hardness level to within the recommended range.  
C. If the CH is too high (commonly known as “hard” water), formation of scale on the spa’s shell surface and equipment can result. CH can be  
decreased by dilution – a mixture of 75% hard and 25% soft water will usually yield a reading within the correct range. If soft water is  
not available or practical for you, a stain and scale inhibitor, such as Hot Spring FreshWater Stain and Scale Defense, should be added to the  
spa water, according to label instructions.  
D. Once the CH is balanced, it normally remains stable, although the addition of more water with a high or low calcium content will raise or lower  
the CH reading of the water.  
E. When the Calcium Hardness is within the recommended range, proceed to the next step.  
Water Quality and Maintenance  
Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BALANCING THE PH  
A. The ideal pH level for your spa water is 7.4-7.6.  
B. The pH level is the measure of acidity and alkalinity. Values above 7 are alkaline; those  
below 7 are acidic. Maintaining the proper pH level is extremely important for:  
• Optimizing the effectiveness of the sanitizer.  
• Maintaining water that is comfortable for the user.  
• Preventing equipment deterioration.  
C. If the spa water’s pH level is too low, the following may result:  
• The sanitizer will dissipate rapidly.  
• The water may become irritating to spa users.  
• The spa’s equipment may corrode.  
If the pH is too low, it can be increased by adding sodium hydrogen carbonate, or  
®
®
Hot Spring FreshWater pH/Alkalinity Up, to the spa water.  
D. If the pH level is too high, the following may result:  
• The sanitizer is less effective.  
• Scale will form on the spa shell surface and the equipment.  
• The water may become cloudy.  
• The filter cartridge pores may become obstructed.  
If the pH is too high, it can be decreased by adding sodium bisulfate, or Hot Spring FreshWater pH/Alkalinity Down, to the spa water.  
NOTE: After adding sodium hydrogen carbonate, or sodium bisulfate, wait two hours before testing the water for pH. Measurements taken too  
soon may not be accurate.  
E. It is important to check the pH on a regular (weekly) basis. The pH will be affected by the bather load, the addition of new water, the addition  
of various chemicals, and the type of sanitizer used.  
F. When the pH is within the recommended range, proceed to the final step.  
MAINTAINING THE SANITIZER LEVEL  
A. Sanitizer is extremely important for killing algae, bacteria and viruses, and preventing unwanted organisms from growing in the spa. At the same  
time, you don’t want too high a sanitizer level, or it can irritate your skin, lungs and eyes.  
B. Always maintain the sanitizer level in your spa at the recommended level for each type of sanitizer.  
C. Watkins recommends the following sanitizer:  
®
• Spa Frog sanitizing system (mineral and bromine)  
C. Watkins also approves the following sanitizers:  
• Sodium Dichloro-s-Triazinetrione (sodium dichlor or chlorine)  
®
• Baqua Spa (please consult your Baqua Spa manual for instructions on the use of this product).  
• Brominating Concentrate (one step granular bromine)  
WARNING: DO NOT use tri-chlor chlorine, bromo-chloro-dimethyl-hydantoin (BCDMH), or any type of compressed bromine or chlorine, acid,  
or any type of sanitizer which is not recommended by Watkins Manufacturing Corporation.  
Page 22  
Water Quality and Maintenance  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER MAINTENANCE QUICK REFERENCE GUIDE  
Ideal Range (ppm) What Chemicals to Use  
Steps  
Minimum  
Maximum  
To Raise  
To Lower  
1
Total Alkalinity  
125  
150  
Sodium Hydrogen  
Carbonate, or  
Sodium Bicarbonate  
Sodium Bisulfate  
2
Calcium Hardness  
150  
200  
7.6  
Calcium Hardness  
Increaser  
Use a mixture of  
75% hard water  
and 25% soft water  
or use a Stain and  
Scale Inhibitor  
3
4
pH  
7.4  
Sodium Hydrogen  
Carbonate  
Sodium Bisulfate  
Sanitizer  
See section on Maintaining the Sanitizer Level  
!
SPA FROG WATER CARE SYSTEM  
The SPA FROG WaterCare system is comprised of the following products:  
• The SPA FROG mineral cartridge that introduces minerals into the spa water, inhibiting bacteria growth. When combined with MPS it  
oxidizes particulates in the spa water.  
• The SPA FROG Bromine (BCDMH) is the only recommended sanitizer that will work in conjunction with the Spa Frog mineral cartridge in  
this system.  
• Monopersulfate (MPS) is an oxidizing chemical used to prevent the buildup of contaminants, maximize sanitizer efficiency, and improve  
water clarity.  
®
FreshWater III high output ozone system uses Corona Discharge technology to produce a high concentration of  
ozone, which is injected into the spa water.  
NOTE: Refer to your SPA FROG Owner’s Manual for start-up and operations instructions. The owner’s manual is included with the SPA  
FROG starter kit.  
It is important to follow the recommended application and maintenance programs outlined for each product’s use. If the spa is being used over an  
extended period of time, such as a whole afternoon or evening, additional sanitizer will be needed.  
A weekly“shock treatmentis required. The shock treatment quickly destroys any remaining contaminants while revitalizing the bromine in the  
water.  
To weekly “shock treat” your spa you may use MPS (sodium dichlor may also be used). Sodium dichlor may be a more appropriate weekly shock  
for those users that experience heavy bather load conditions.  
IMPORTANT NOTE: MPS is an oxidizer, not a sanitizer.  
SPA FROG CARTRIDGE REPLACEMENT INSTRUCTIONS  
The SPA FROG bromine cartridge should be replaced every 2-4 weeks, depending on User Load. The SPA FROG mineral cartridge should be  
replaced every 4 months. When replacing the mineral cartridge, it is highly recommended that the spa be drained and refilled at the same time.  
After refilling the spa with water, balance the Total Alkalinity (A), Calcium Hardness (CH) and pH to the recommended levels. Shock the spa by  
adding MPS.  
To replace SPA FROG cartridges, follow these steps:  
1. Turn off power to the spa.  
2. Unscrew SPA FROG cap on top edge of spa.  
3. Turn handle counter-clockwise.  
4. Lift cartridge holder up and out of spa.  
5. Turn top cap of mineral cartridge to setting #6 (The mineral cartridge should last 4 months.) Turn top cap of bromine cartridge to setting #7.  
NOTE: Adjust bromine cartridge setting down by one setting each day until a residual of 1.0 - 2.0 ppm level of bromine is established. (The  
bromine cartridge should last 2-4 weeks.)  
6. Snap bromine cartridge in at bottom of holder and mineral cartridge on top.  
NOTE: It is important that the bromine cartridge is on bottom; otherwise, the bromine cartridge could be dispensed prematurely.  
Water Quality and Maintenance  
Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
!
HOT SPOT WATER TREATMENT GUIDE  
At spa start-up or refill  
Follow spa Start-Up and Refill Procedures.  
Add one (1) tablespoon of monopersulfate (MPS)* per  
250 gallons (950 liters).  
Prior to each use  
(Test before adding any chemicals; do  
not add any chemicals if proper or  
higher levels are found.)  
La Palma  
Mallorca  
Sorrento  
Trinidad  
2 tablespoon  
1-1/2 tablespoon  
1-1/4 tablespoon  
1-1/4 tablespoon  
Add three (3) tablespoons of monopersulfate (MPS)* per  
250 gallons (950 liters).  
Once a week  
La Palma  
Mallorca  
Sorrento  
Trinidad  
5-1/2 tablespoon  
4-1/2 tablespoons  
3-3/4 tablespoons  
3-3/4 tablespoons  
Drain spa, repace mineral cartridge, and refill your spa. Follow  
spa Start-Up and Refill  
Procedures  
Every four months  
Add one and one half (1-1/2) teaspoons of sodium dichlor  
per 250 gallons (950 liters).  
As needed  
(If water is hazy, cloudy or has an odor)  
La Palma  
Mallorca  
Sorrento  
Trinidad  
3 teaspoons  
2-1/4 teaspoons  
1-3/4 teaspoons  
1-3/4 teaspoons  
*MPS is an oxidizer, not a sanitizer.  
7. Reinstall cartridge holder into spa, push down, and twist clockwise.  
®
8. Replace SPA FROG cap.  
9. Reconnect power to spa.  
Warning: High sanitizer levels can cause discomfort to the user’s eyes, lungs and skin. Always allow the sanitizer level to fall to the recommended  
range before using the spa.  
IMPORTANT: Each time the spa is filled with water, you must remove and reinstall the SPA FROG cap, even if you are not replacing the cartridge,  
in order to properly prime the jet pumps.  
FOLLOWING THE SPA FROG SANITIZER ROUTINE  
During the first month of ownership, measure the sanitizer residual daily in order to establish the correct setting on cartridges for User Load and  
Usage Time versus Sanitizer Needed.  
• The User Load of the spa is the number of times anyone enters the spa.  
• The Usage Time is simply the amount of time a user spends in the spa.  
• Sanitizer Needed is the amount needed to accomodate the number of users and their combined usage time.  
For example, two spa users who regularly use the spa once an evening for twenty minutes create a specific and somewhat consistent demand on  
the sanitizer. During the first month of ownership, these two users can determine exactly how much sanitizer to use in order to maintain the proper  
residual. If, at any time the user load and/or usage pattern changes dramatically (i.e. invited guests), the frequency of sanitizer required increases  
dramatically. The greater the usage time, or the bather load, the faster the residual value is diminished.  
Page 24  
Water Quality and Maintenance  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DO’S AND DON’TS  
DO check your bromine chemical level prior to each use.  
DO change the SPA FROG® mineral cartridge every 4 months.  
DO test Total Alkalinity and pH weekly.  
DO use MPS for spas only, such as Hot Spring® MPS Chlorine-Free Oxidizer.  
DO store all chemicals in a tightly sealed container in a cool, dry place.  
DON’T use sodium bromide or biguanides. These are an active sanitizer and will combine with the silver ions to inactivate them.  
DON’T use a water clarifier. Clarifiers will cause the spa water to become cloudy.  
DON’T use the FreshWaterAg ® silver ion purifier cartridge with SPA FROG.  
+
BROMINE  
A. Sanitizing chemicals, such as bromine, are oxidants that kill bacteria and viruses in the water. If you are using the SPA FROG system, the  
recommended bromine level for your spa water is 1.0 - 2.0 ppm. If you are not using the SPA FROG system, your bromine level should be  
between 3.0 - 5.0 ppm.  
B. Watkins Manufacturing Corporation recommends the use of granulated bromine for sanitizing the water. Granulated bromine is preferred  
because it is totally soluble, dissolves quickly and is nearly pH neutral.  
C. Maintaining the proper level of bromine during use is extremely important.  
D. If the bromine level is too low, bacteria and viruses can grow rapidly in the warm water.  
E. If the bromine level is too high, the water can cause discomfort to the user’s eyes, lungs and skin. Simply allow some time to pass.  
F. When the bromine level is within the recommended range, the spa is ready to be enjoyed.  
WARNING: There are several forms of stabilized chlorine available for use in spas and swimming pools and each form has specific  
chemical characteristics. It is extremely important that the one you choose is specifically designed for use in spas. Use of an incorrect product  
such as tri-chlor, which has a very low pH (2.6), dissolves too quickly in hot water resulting in extremely high levels of chlorine, and is designed  
for concrete or plaster swimming pools, WILL cause damage to your spa. Use of a liquid, or any type of compressed bromine or chlorine,  
acid, or any type of sanitizer which is not recommended by Watkins Manufacturing Corporation WILL damage your spa and is specifically not  
covered under the terms of the limited warranty.  
IMPORTANT: Granulated chlorine (sodium dichlor) will degrade if stored improperly. We recommend purchasing chlorine in one, two, or five  
pound containers and storing it in a cool, dry place to maintain its potency.  
SUPER CHLORINATION  
Super Chlorination is designed to “burn-off” the build-up of chloramines (used chlorine), to eliminate the chlorine smell and to allow the proper  
level of free chlorine to be maintained.  
When giving your water a super chlorination treatment, open the cover at least half way for twenty  
minutes to allow the chlorine gas to vent off. The high concentration of chlorine gas which may  
exist as a result of super chlorination (not daily sanitation) may eventually cause discoloration or  
degradation to the bottom of the cover, which would not be covered under the terms of your  
warranty.  
WARNING: There are several froms of stabilizer chlorine available for use in spas and  
swimming pools. Each from has specific chemical characteristics. It is extremely important that the  
form you choose is specifically designed for use in spas. Use of an incorrect product such as tri-  
chloro, which has a very low pH (2.6) dissolves too quickly in hot water resulting in extremely  
high levels of chlorine, and is designed for concrete or plaster swimming pools. WILL cause  
damage to your spa. Use of a liquid, or any type of compressed bromine or clorine, acid, or any  
type of sanitizer which is not recommended by Watkins Manufacturing Corportation, WILL  
damage your spa and is specifically not covered under the terms of the limited warranty.  
SUPPLEMENTAL WATER MAINTENANCE  
Proper water sanitation and mineral balance (pH control) are absolutely essential for a complete  
spa water maintenance program. Here are three other popular water additives that are optional:  
Mineral Deposit Inhibitors  
As water evaporates from your spa and new water is added, the amount of dissolved minerals will increase. (Minimize evaporation by keeping the  
cover on the spa whenever possible.) The spa water may eventually become “hard” (Calcium Hardness too high) enough to damage the heater by  
calcifying its surface. Proper pH control can minimize this.  
Normal soap build-up will require water replacement regularly enough that mineral deposits normally are not a problem.  
Occasionally, high iron or copper content in the water may produce green or brown stains on the spa. A mineral deposit inhibitor, such as Hot  
Spring® FreshWater® Stain and Scale Defense, may help to reduce these metals.  
Water Quality and Maintenance  
Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE: Well water may contain high concentrations of minerals. The use of a low water volume, extra-fine pore water filter (in-line pre-filter such as  
the FreshStart®10,000 pre-filter) will help to remove many of the larger particles during the filling of the spa. In-line pre-filters can be purchased at  
your local Hot Spot® Spa Dealer.  
Foam Inhibitors  
Spa water requires changing due to the build-up of soap in the water. Typically, soap will cause the spa water to foam when the jets are used.  
Soap is introduced into the spa water from two sources; users’ bodies, which retain a soap residue after showering, and swimming apparel, which  
retains soap after washing.  
®
®
Foam inhibitors, such as Hot Spring FreshWater Defoamer, can suppress foam, but cannot remove soap from the water. Soap is very difficult to  
remove from the water because soap is not oxidized by any chemical added to the spa. Only ozone can oxidize soap.  
Eventually the soap build-up in the water will be concentrated, resulting in an unclean feeling on the bather’s skin, which is impossible to remedy.  
When this occurs, it’s time to drain and refill the spa. Depending on the soap input, the water should last about 4 months before needing to be  
drained.  
OZONE (OPTIONAL)  
The FreshWater® III high output ozone system is the Watkins recommended ozone purification system for your spa. The FreshWater III ozone  
system utilizes Corona Discharge (CD) technology to produce a higher concentration of ozone than is produced by competing ultraviolet light (UV)  
ozone systems.  
The FreshWater III high output ozone system greatly enhances the quality of the spa water when used to supplement the spa owner’s regular  
water maintenance program. Contrary to some information circulated throughout the pool and spa industry regarding ozone systems, ozone CAN  
NOT be used as a single-source sanitizer, water clarifier, anti-foamer, and mineral chelating agent. A secondary-source sanitizer must be used to  
maintain 2.0 ppm (2.0 mg/L) of Free Available Chlorine (FAC). Watkins Manufacturing Corporation recommends that a chemical maintenance  
program based on recognized and documented industry standards still be followed when using an ozone purification system to assure water  
sanitation and the highest quality purified water.  
Cleaning the Ozone Injector  
On occasion, a mineral build-up may clog the ozone injector causing a lack of flow or low flow of ozone bubbles. To prevent this, refer to the  
following instructions to clean the injector:  
1. Disconnect power to the spa.  
2. Access the equipment compartment.  
3. Locate the ozonator in the equipment compartment and unplug the ozonator from the control box.  
4. Place 16 ounces (1/2 liter) of white vinegar into a container such as a cup or bucket. Place the container on the equipment compartment floor.  
WARNING  
WARNING  
Nitric acid accumulates in the air lines of the ozonator and injector. Nitric acid will cause  
severe chemical burns if direct skin contact is made, so always wear protective gloves,  
glasses and clothing when working on the ozonator or injector lines. To prevent inhalation  
or ingestion of the nitric acid, DO NOT blow or inhale with your mouth to any of the  
adapters, fittings or tubing of the ozonator or injector air lines.  
NOTE: White vinegar will not damage any of the spa components.  
5. Carefully loosen the long Tygon / Kynar tubing to the bottom of the ozonator. A liquid substance may be found inside the tubing. If a liquid  
substance is present, BE CERTAIN NOTTO COME INTO CONTACTWITHTHE LIQUID (SEEWARNING ABOVE).  
6. Place the end of the tubing into the vinegar, making certain that the end of the tubing sits at the bottom of the container.  
7. Reconnect power to the spa.  
8. Run the spa until all 16 ounces (1/2 liter) of the vinegar are gone. This should allow an ample flow of vinegar to be run through the injector and  
clear the blockage.  
9. Disconnect power to the spa.  
10. Remove the empty cup or bucket.  
11. Reinstall the tubing to the bottom of the ozonator.  
12. Plug the ozonator into the control box.  
13. Close the equipment compartment door.  
14. Reconnect power to the spa.  
Page 26  
Water Quality and Maintenance  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT: When using the FreshWater® III high output ozone system, the circulation cycle must be activated to ensure adequate ozone  
circulation. Refer to the circulation cycle in the HEATING AND HYDROMASSAGE SYSTEM section for more information.  
DO’S AND DON’TS  
DO add all chemicals slowly into the filter compartment with the jet pump operating on high speed for ten minutes.  
DO use special care if using baking soda to clean either the interior or exterior plastic surfaces.  
DO use only a granular form of sanitizer.  
DON’T use swimming pool (muriatic) acid to lower pH.  
DON’T splash pH increaser additives on the siding.  
DON’T use Compressed Sanitizers.  
The use of bromine sticks or tablets in floaters, which may become entrapped in a lounge or cooling seat (or sink to the spa floor), have been  
shown to cause discoloration of or surface distress to a spa’s shell.  
DON’T use a floater type sanitization system as a low or no maintenance solution to your spa maintenance program.  
The spa shell can easily withstand the effects of a properly administered sanitizer. Floating dispensers can become trapped in one area and cause  
an over-sanitization (or chemical burn) of that particular area.  
If the dispenser setting is too high, the high concentration can discolor the spa shell and damage the underside of the cover.  
Automatic floating dispensers have a tendency to either over-brominate or under-brominate as the rate of erosion varies greatly. Damage to the  
spa and cover can occur very quickly.  
WARNING: Watkins Manufacturing Corporation DOES NOT recommend the use of any floating chemical dispenser. Damage to the spa shell  
or components caused by a floating chemical dispenser is specifically not covered under the terms of the limited warranty.  
DON’T use a sanitizer which is not designed for spas.  
DON’T use household bleach (liquid sodium hypochlorite).  
DON’T broadcast or sprinkle the chemicals onto the water surface. This method may cause chemically-induced spa surface blistering  
(chemical abuse).  
COMMON WATER CHEMISTRY QUESTIONS  
Question: Why can’t I use a floater to sanitize my spa water?  
Answer: Watkins Manufacturing Corporation does not recommend the use of a floater for three reasons:  
1. The floater is unable to control the rate at which the sanitizer is dissolved into the water. When a floater is first placed in a spa, the sanitizer  
level can be extremely high. High sanitizer levels can chemically burn or discolor the spa’s shell or the underside of the cover. Then, after a  
period of time, the sanitizer level dispensed by the floater will fall to near zero. A low sanitizer level will allow viruses, bacteria, or algae to grow.  
2. Floaters tend to stay in one area of the spa most of the time (usually over the cool-down seat), causing this area to be exposed to extreme  
sanitizer levels.  
3. The floater may allow pieces of the highly concentrated sanitizer to fall out and settle on the floor or seat of the spa shell. These pieces of  
sanitizer will chemically burn (blister) the spa shell. Although your spa shell is specifically designed to resist the effects of spa chemicals, no  
spa surface can withstand this type of highly concentrated chemical. Remember, chemical abuse is specifically not covered under the terms  
of the warranty.  
Question: When I open my spa, I smell chlorine. How do I get rid of this smell?  
Answer: There are two types of chlorine in your spa. The first is the Free Available Chlorine, which is the chlorine available to sanitize your spa.  
This Free Available Chlorine does not have an odor. The second is Chloramine, which is residue from chlorine already expended. Chloramines  
have a strong chlorine odor. The smell from Chloramines can be eliminated by “shocking” the water. If you smell chlorine in the water, your spa is  
reminding you to add a shock treatment.  
Question: Why can’t I fill my spa with soft water?  
Answer: Soft water is essentially the same as regular water except that most or all of the calcium has been replaced by sodium. Soft water may  
be corrosive to the heater and other components. Replacement of spa components damaged by soft water is extremely expensive.  
Question: I am trying to reduce the number of chemicals to which my family is exposed. Do I really need to use so many chemicals and in such  
large amounts?  
Answer: While over-exposure to any chemical can be unhealthful, many low levels of chemicals are effective and beneficial. In the case of spa  
water, the chemicals recommended in the Hot Spot® Spa Water Maintenance program are needed to protect the user from water-borne pathogens  
(disease-causing microbes) and to prevent corrosion of spa components.  
Question: Why isn’t water chemistry damage covered by the warranty?  
Answer: The chemical levels and water quality of the water in the spa are under your direct control. With proper basic care, the spa will provide  
many years of hot water relaxation. If you are unsure about any chemical or its usage in the spa, contact your Authorized Dealer or Watkins  
Manufacturing Corporation.  
Water Quality and Maintenance  
Page 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER TERMINOLOGY  
The following chemical terms are used in this Water Quality and Maintenance section. Understanding their meaning will help you to better  
understand the water maintenance process.  
Bromamines: Compounds formed when bromine combines with nitrogen from body oils, urine, perspiration, etc. Unlike chloramines,  
bromamines have no pungent odor and are effective sanitizers.  
Bromine: A halogen sanitizer (in the same chemical family as chlorine). Bromine is commonly used in stick, tablet, or granular form. See the DOs  
and DON’Ts of Spa Water Maintenance for additional information.  
Calcium Hardness: The amount of dissolved calcium in the spa water. This should be approximately 150-200 ppm. High levels of calcium can  
cause cloudy water and scaling. Low levels can cause harm to the spa equipment.  
Chloramines: Compounds formed when chlorine combines with nitrogen from body oils, urine, perspiration, etc. Chloramines can cause eye  
irritation as well as having a strong odor. Unlike bromamines, chloramines are weaker, slower sanitizers.  
Chlorine: An efficient sanitizing chemical for spas. Watkins Manufacturing Corporation recommends the use of sodium dichlor-type granulated  
chlorine. This type is preferred because it is totally soluble and nearly pH neutral.  
Chlorine (or Bromine) Residual: The amount of chlorine or bromine remaining after chlorine or bromine demand has been satisfied. The residual  
is, therefore, the amount of sanitizer which is chemically available to kill bacteria, viruses and algae.  
Corrosion: The gradual wearing away of metal spa parts, usually caused by chemical action. Generally, corrosion is caused by low pH or by water  
with levels of TA, CH, pH or sanitizer which are outside the recommended ranges.  
DPD: The preferred reagent used in test kits to measure the Free Available Chlorine.  
Halogen: Any one of these five elements: fluorine, chlorine, bromine, iodine and astatine.  
®
MPS: Monopersulfate is the non-chlorine oxidizer used with the FreshWaterAg silver ion purification system.  
+
Oxidizer: The use of an oxidizing chemical is to prevent the buildup of contaminants, maximize sanitizer efficiency, minimize combined chlorine,  
and improve water clarity.  
Pathogen: A microorganism such as bacterium that cause disease.  
pH: The measure of the spa water’s acidity and alkalinity. The recommended pH for the spa water is 7.4 to 7.6. Below 7.0 (considered neutral), the  
spa water is too acidic and can damage the heating system. Above 7.8, the water is too alkaline and can result in cloudy water and scale  
formation on the shell and heater.  
ppm: The abbreviation of “parts per million”, the standard measurement of chemical concentration in water. Identical to mg/l (milligrams per liter).  
Reagent: A chemical material in liquid, powder, or tablet form for use in chemical testing.  
Sanitizer: Sanitizers are added and maintained at recommended residuals to protect bathers against pathogenic organisms which can cause  
disease and infection in spa water.  
Scale: Rough calcium-bearing deposits that can coat spa surfaces, heaters, plumbing lines and clog filters. Generally, scaling is caused by mineral  
content combined with high pH. Additionally, scale forms more readily at higher water temperatures.  
ShockTreatment: Also known as “super-chlorination” when chorine is used. Shock treatment is a process of adding significant doses of a quick  
dissolving sanitizer (sodium dichlor is recommended) to oxidize non-filterable organic waste and to remove chloramines and bromamines.  
Total Alkalinity: The amount of bicarbonates, carbonates, and hydroxides present in spa water. Proper total alkalinity is important for pH control.  
If the TA is too high, the pH is difficult to adjust. If the TA is too low, the pH will be difficult to hold at the proper level. The desired range of TA in spa  
water is 125 to 150 ppm.  
MAINTENANCE AND SPA CARE  
FILTER MAINTENANCE  
At least once a week, check and clean the skimmer basket and weir to ensure proper filter flow. Remove leaves, foreign matter, and debris. It is  
very important to keep your spa filter cartridge clean and free of particles to ensure proper water flow. A clean filter permits the hydrotherapy  
system to function properly and also allows more efficient filter cycles. Depending on how frequently your spa is used, we recommend cleaning  
the spa filter cartridge every four weeks. If this is not done, the filter may clog and restrict water flow, which causes improper filtration and poor jet  
performance.  
WARNING: The frequency and duration of use, and the number of occupants all contribute to determining the appropriate time between filter  
cleanings. More use means that more frequent filter cleanings will be required.  
Page 28  
Maintenance and Spa Care  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FILTER CARTRIDGE REMOVAL AND CLEANING FOR MALLORCA®, SORRENTO® & TRINIDAD®  
Turn the spa OFF or turn the power to the spa OFF, then proceed as follows:  
1. Push down slightly and turn filter basket counterclockwise to unlock,  
FLOATING  
then pull the basket and weir out.  
WEIR  
2. Carefully pull up the filter cartridge and bring it out of the spa.  
BASKET  
3. Rinse cartridge using a garden hose. Rotate and separate filter  
FRESHWATER  
Ag+SILVER ION  
PURIFIER  
pleats while spraying water to remove all debris possible. Let the  
filter dry and then look for calcium deposits (scaling) or an oil film. If  
you find these, you will need to deep clean your filter cartridge with a  
“spa filter cleaning” solution to break down and remove mineral  
deposits and oils.  
FILTER  
CARTRIDGE  
4. To return basket and weir, insert and rotate clockwise to lock into  
position.  
PLEATS  
FRESHWATER  
Ag+SILVER ION  
PURIFIER  
FILTER CARTRIDGE REMOVAL AND CLEANING FOR  
LA PALMATM  
1. Disconnect the spa from the power supply by turning the power to the  
spa OFF.  
STANDPIPE  
2. Remove and carefully set aside the filter compartment cover.  
3. Remove any floating items from within the filter compartment.  
MALLORCA • SORRENTO  
TRINIDAD  
4. Turn the filter retainer handle (located on the top of the filter cartridge)  
counterclockwise until the retainer can be removed from the filter  
standpipe.  
5. Remove the filter retainer and cartridge.  
SERVICE NOTE: Never remove the filter standpipe(s) when debris is  
present in the filter compartment. Debris may find its way into the  
internal plumbing which may result in blockage. NEVER REMOVE  
SUCTION FITTINGS!  
RETAINER  
HANDLE  
6. Always clean the filter using a filter degreaser, such as Hot Spring®  
FreshWater® Filter Cleaner, to remove mineral and oil build-up. Simply  
soak the filter in the degreaser according to the package directions,  
then place the filter on a clean surface and spray until clean using a  
garden hose. It may be necessary to rotate the filter while spraying to  
remove any debris lodged between the filter pleats.  
FILTER  
CARTRIDGE  
STANDPIPE  
7. To reinstall the filter cartridge, reverse the order of steps in which it  
was removed. Do not overtighten  
FRESHWATER  
Ag+SILVER ION  
PURIFIER  
CARE OF THE SPA PILLOWS  
INSIDE  
STANDPIPE  
The spa pillows will provide years of comfort if treated with care. They  
have been positioned above the water level to minimize the bleaching  
effects of chlorinated water and other spa water chemicals. To extend their  
LA PALMA  
life, whenever the spa shell is being cleaned, the spa pillows should be removed and cleaned. Body oils can be removed with a mild soap and  
water solution. ALWAYS rinse off the spa pillows thoroughly to remove any soap residue. If the spa is not going to be used for a long period of time  
(that is during a vacation or if the spa is winterized), or when the spa water is being super-chlorinated, the spa pillows should be removed  
until the next use of the spa.  
To remove and replace the spa pillows:  
1. Carefully lift one end of the pillow away from the spa shell.  
2. Continue lifting one end until all pillow retainers are released from the pillow.  
IMPORTANT: Just pulling the pillow straight up and out of the shell recess will eventually damage the pillow. This abuse is not covered under  
warranty.  
3. To reinstall the spa pillow, carefully bend the pillow slightly to allow one of the pillow retainers to slip into the recess in the back of the pillow.  
4. Keeping the pillow slightly bent, slide the other pillow retainer into the recess in the back of the pillow.  
5. After all the pillow retainers are in place, press the pillow down into the recess in the spa shell.  
Maintenance and Spa Care  
Page 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARE OF THE EXTERIOR  
SPA SHELL  
Your Hot Spot® spa has an acrylic like shell. Stains and dirt generally will not adhere to your spa’s surface. A soft rag or a nylon scrubber should  
easily remove most dirt. Most household chemicals are harmful to your spa’s shell. Watkins Manufacturing Corp. recommends Soft Scrub® and  
Windex®. These are the only products which have passed the manufacturer’s tests. Sodium bicarbonate (baking soda) can also be used for minor  
surface cleaning. Always thoroughly rinse off any spa shell cleaning agent with fresh water.  
SERVICE NOTES:  
1. Iron and copper in the water can stain the spa shell if allowed to go unchecked. Ask your Hot Spot dealer for a stain and scale Inhibitor to use  
if your spa water has a high concentration of dissolved minerals.  
2. The use of alcohol or any household cleaners other than those listed to clean the spa shell surface is NOT recommended. DO NOT use any  
cleaning products containing abrasives or solvents since they may damage the shell surface. NEVER USE HARSH CHEMICALS! Damage to  
the shell by the use of harsh chemicals is not covered under the warranty.  
IMPORTANT: Some surface cleaners contain eye and skin irritants. Keep all cleaners out of the reach of children and use care when applying.  
CARE OF THE SPA COVER  
WARNING: The cover is a manual safety cover that meets or exceeds all prevailing requirements of ASTM Standards for spa safety covers  
when installed and used correctly as of the date of manufacture. Non-secured or improperly secured covers are a hazard. Open the cover to its  
fully open position before use.  
VINYL COVER  
The vinyl spa cover is an attractive, durable foam insulation product. Monthly cleaning and conditioning are recommended to maintain its beauty.  
To clean and condition the vinyl cover:  
1. Remove the cover from the spa and gently lean it against a wall or fence.  
2. With a garden hose, spray the cover to loosen and rinse away dirt or debris.  
3. Using a large sponge and/or a soft bristle brush, and using a very mild soap solution (1 teaspoon dishwashing liquid with 2 gallons of water) or  
baking soda (sodium bicarbonate), scrub the vinyl top in a circular motion. Do not let the vinyl dry with a soap film on it before it can be rinsed clean.  
4. Scrub the cover’s perimeter and side flaps. Rinse clean with water.  
5. Rinse off the underside of the cover with water only (use no soap), and wipe it clean with a dry rag.  
SERVICE NOTE: To remove tree sap, use cigarette lighter fluid (not charcoal lighter fluid). Use sparingly, and rinse with a saddle soap solution  
immediately afterwards, then wipe dry.  
Important reminders:  
DO remove snow buildup to avoid breakage of the foam core from the additional weight of the snow.  
DO lock cover lock straps to secure the cover when the spa is not in use.  
DO NOT drag or lift the spa cover using either the flaps or the cover lock straps.  
DO NOT walk, stand, or sit on the cover.  
DO NOT place any metal or heat transferring object on the cover or place any type of plastic tarp or drop cloth over the cover as this may  
result in a melted foam core, which would not be covered under the warranty.  
DO NOT use any lifting mechanisms, chemicals or cleaners except those recommended by Watkins® Manufacturing Corporation or its  
Authorized Sales and Service Dealer.  
WOOD SPA CABINET  
This spa cabinet is available on Mallorca®, Sorrento® & Trinidad® spas and is constructed of high-quality wood. The wood cabinet is factory-sealed  
with a lightly tinted stain for beauty and protection. As with all wood products, prolonged exposure will cause discoloration and drying. Do not use  
wood sealers or wood furniture-type oils such as tung, teak or lemon to seal the cabinet, as they will cause the wood to blacken. Discoloration or  
aging of the redwood cabinet is considered natural and is not covered by the limited warranty.  
NOTE: Always test a small area (such as one or two vertical corner boards) or your spa cabinet for stain compatibility before applying a non-  
recommended stain.  
SIMULATED SPA CABINET  
This cabinet is available on La PalmaTM model, Mallorca & Sorrento models. Simulated wood consists of a rigid polymer that combines the  
durability of plastic, with the beauty of wood. Simulated wood won’t crack, peel, blister, or delaminate even after prolonged exposure to the  
elements.  
Cleaning of Simulated wood consists of simply spraying the cabinet with a mild soap and water solution to remove any stains and residue.  
Page 30  
Maintenance and Spa Care  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DRAIN CAP  
DRAINING YOUR SPA  
1. TURN OFF OR DISCONNECT POWER FROMTHE SPA.  
2. Remove the equipment compartment access door.  
3. Locate the drain cap. Lift drain hose above the water level (requires cutting  
plastic tie the first time).  
4. Unscrew and remove the drain cap.  
5. Attach drain hose to garden hose and direct to an appropriate draining area.  
Maintain hose below water line.  
6. After your spa is empty, clean the shell and filter cartridge.  
7. After cleaning, remove garden hose and put drain cap back in place.  
8. Replace the equipment compartment access door.  
DRAIN  
HOSE  
NON-OPERATION IN COLD CLIMATE  
DOOR  
GARDEN HOSE  
If the spa is to be left unused for an extended period of time in areas where  
FREEZING TEMPERATURES DO NOT OCCUR, it may be desirable to turn the  
heater to the lowest temperature. The automatic filter cycles will keep the spa water clean and sparkling. When preparing the spa for use, check  
the water chemistry to assure correct chlorine or bromine and pH levels.  
You can keep the water in the spa during the time of year when freezing at the spa location may occur. If a freeze condition is detected, the pump  
and heater will be activated automatically to circulate the water in low speed. However, CAUTION must be used with this approach. In the event of  
electrical power interruption, regardless of the cause, the heater and pump will stop operating and freeze protection will be lost, possibly resulting  
in freeze damage to the spa, spa plumbing and/or components. Such damage is not covered by warranty.  
WINTERIZING YOUR SPA  
If the spa is located where freezing temperatures occur, and you do not intend to use your spa for an extended period, follow steps 1 through 7  
outlined in “Draining Your Spa” (above) then complete the steps below.  
IMPORTANT: The following steps should protect your spa from freezing damage provided these instructions are followed exactly. For maximum  
protection against freeze damage to your spa, Watkins Manufacturing Corporation recommends contacting your local Hot Spot® dealer to  
schedule an in-home Propylene glycol (anti-freeze) Winterizing Service plan.  
NOTE: MAKE CERTAIN ALL POWERTOTHE SPA IS OFF and all water has  
been drained from the spa before you continue.  
PUMP DRAIN PLUG LOCATION  
1. It will be necessary to remove all water from the interior plumbing.  
2. Remove the floating weir basket and filter cartridge. Clean the filter cartridge  
and store in a dry place. Attach the vacuum hose to the vacuum side of the  
shop vac and thoroughly dry the filter compartment.  
3. Using the shop vac, remove the water starting with the jets at the top and  
moving to the ones at the bottom of the spa.  
DRAIN  
PLUG  
NOTE: When removing the water from the jet openings, you may notice  
suction coming from another jet. With the help of a second person,  
block off any suction from the other jet using a large rag or cloth. This will  
help pull out the water that is trapped deep inside the main line.  
4. Thoroughly dry the spa shell with a clean towel.  
5. Using a funnel, pour Propylene glycol anti-freeze into the filter suction fittings  
and jet outlets. Add enough anti-freeze until the liquid starts to  
come out of the bottom drain.  
Front view of pump  
CAUTION: Use only Propylene glycol as your anti-freeze.This is non-  
toxic. NEVER use automobile anti-freeze since it is toxic.  
6. Close the spa cover and fasten the cover tie downs. If your area receives a lot of snow or ice, it is recommended to cover the spa cover with  
two pieces of plywood forming a pitched roof top to prevent snow and ice build-up. Secure a plastic sheet or tarp over the spa cover and one  
over the plywood.  
WARNING: When not in use, the spa must be covered with an insulating spa cover. Damage caused by either sun exposure or freezing is not  
covered under warranty.  
7. In the pump side of the equipment control bay, remove the pump drain plug located on the front of the pump housings. Allow all water to  
drain out. Place the drain plug in a reclosable plastic storage bag and store near the pump. Replace the drain plugs on start-up.  
8. Unscrew the suction/discharge pump and heater unions and allow the water to drain. Leave union loose. NOTE: Tighten unions before filling.  
9. Replace the equipment doors and secure with screws.  
Maintenance and Spa Care  
Page 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICE INFORMATION  
GENERAL INFORMATION  
Your Hot Spot® Spa has been designed to provide years of trouble-free use. As with any appliance, problems may occasionally occur that require  
the expertise of a qualified service person. Though such simple repairs as resetting a GFCI switch or breaker, high limit thermostat, or pressure  
switch, or replacing a light bulb may not require a service call, they may indicate that a more serious condition exists. These conditions may  
require an experienced service person. Before calling for service, please refer to the Troubleshooting Guide.  
NOTE: Always retain your original sales receipt for future reference.  
GFCI AND HIGH-LIMIT THERMOSTAT  
If your spa fails to operate at any time, the following items should be checked:  
1. Check the power supply to the spa.  
2. Check the GFCI (located at the end of the cord in standard models or in the electrical subpanel in 30 amp converted models) and see if it has  
tripped. If a GFCI has tripped, reset it. If it will not reset, this may be an indication of a ground fault (short circuit) within the electrical  
components. Contact an Authorized Service Technician for a complete diagnosis.  
3. If, upon checking the GFCI you find it has not tripped, check the house breaker panel and ensure the main breaker for the electrical circuit  
supplying the spa has not tripped. If it has, this is an indication that either the circuit was overloaded or a ground fault exists between the  
breaker panel and the spa receptacle. Contact a qualified electrician.  
4. If, upon checking the main house breaker, you find no failures, the heater high-limit thermostat should be checked. Tripping of the heater high-  
limit thermostat is normally a result of one or a combination of any of these problems: 1) blockage within the system plumbing, 2) switch  
malfunction in the heater circuit, or 3) the low speed mode of the jet pump is not functioning.  
5. If the heater high-limit has tripped, the control panel display will display - - - - . Reset the heater high-limit by allowing the water to cool and  
disconnecting power to the spa for at least thirty seconds. If the heater high-limit continues to trip, contact an Authorized Service Technician  
for a complete diagnosis.  
If the spa does not function and the GFCI or GFCI breaker and heater high-limit have not tripped, then the problem should be referred to an  
Authorized Service Technician. Refer to the Troubleshooting Guide for additional service information.  
MISCELLANEOUS SERVICE INFORMATION  
The jet pump is equipped with an overload cut-off switch, which is designed to protect the pump from overheating. If the pump shuts itself off in a  
new spa, it is usually the result of one, or a combination of, the following factors:  
HighTemperature: During the summer months, especially in warmer climates, the ambient temperature contributes to excessively high  
temperatures within the equipment compartment.  
Improper HouseWiring: If the spa is not connected to a dedicated circuit, or is connected to an extension cord, or the house wiring is  
undersized, the pump may starve for voltage and therefore may draw more amperage and generate excessive heat. This will often cause the  
circuit breaker to trip repeatedly.  
IMPORTANT:  
1. If the pump is shutting down due to excessive heat, make sure the equipment compartment has adequate ventilation. The air gap at the  
bottom and the jet pump vent at the bottom left corner must not be blocked. Should your jet pump continue to shut off after short periods of  
use, contact a qualified service technician.  
2. The Hot Spot® Spa is equipped with a safety suction spring valve which will break the prime of the jet pump if both suction fittings are  
obstructed.  
ACTS INVALIDATING WARRANTY  
The limited warranty is void if the Hot Spot Spa has been subjected to alteration, misuse or abuse, or if any repairs on the spa are attempted by  
anyone other than an authorized representative of Watkins Manufacturing Corporation. Alteration is defined as any component or plumbing  
change, electrical conversion, or the addition of any non-approved sanitation, or water purification device, or heating system which contributes to  
a component failure, unit failure, or unsafe operating condition. Misuse and abuse shall include any operation of the spa other than in accordance  
with Watkins Manufacturing Corporation printed instructions, or use of the spa in an application for which it is not designed; specifically: use of the  
spa in a non-residential application; damage caused by operation* of the spa at water temperatures outside the range of 35°F and 120 °F (2°C and  
49°C); damage caused by a dirty, clogged, or calcified filter cartridge; damage to the spa surface caused by the use of Tri-Chloro Chlorine,  
BCDMH, chemical tablets in a floater, acid, or any other spa chemicals, or spa surface cleaners which are not recommended by Watkins  
Page 32  
Service Information  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Manufacturing Corporation; damage caused by allowing undissolved spa sanitizing chemicals to lie on the spa surface (no spa surface  
material can withstand this kind of abuse); damage to components or spa surface caused by improper water chemistry maintenance; and  
damage to the spa surface caused by leaving the spa uncovered while empty of water and in direct exposure to sunlight (this may cause  
solar heating distress in warm weather regions). These are considered abuses and may invalidate this warranty.  
*Operation of the spa DOES NOT mean “use” of the spa! Watkins Manufacturing Corporation does not recommend using the spa if the  
water temperature is above or below the spa’s control panel temperature range.  
DISCLAIMERS  
Watkins Manufacturing Corporation shall not be liable for loss of use of the Hot Spot Spa or other incidental or consequential costs,  
expenses, or damages, which may include but are not limited to, the removal of a permanent deck or other custom fixture. Any implied  
warranty shall have a duration equal to the duration of the applicable warranty stated above. Under no circumstances shall Watkins  
Manufacturing Corporation, or any of its representatives, be held liable for injury to any person, or damage to any property, however  
arising.  
WATKINS CUSTOMER SERVICE  
If you have any questions about any aspect of your Hot Spot Spa set-up, operation, or maintenance that have not been answered by this  
manual, consult your Hot Spot Spa Dealer.  
Watkins Manufacturing Corporation can be reached at: 800-999-4688 (Extension 8432), Monday through Friday, 8 am to 5 pm Pacific  
Standard Time (PST), or e-mail at Custsvc@watkinsmfg.com.  
Service Information  
Page 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Watkins Manufacturing Corporation strives to provide the most trouble-free spas on the market. Should you experience any problem whatsoever,  
do not hesitate to contact your authorized Hot Spot® Spa Dealer. Here are some tips to help you to diagnose and rectify some more common  
sources of trouble yourself, if you choose to do so.  
GENERAL OPERATION TROUBLESHOOTING GUIDE  
Problem  
Probable causes  
Solutions  
Entire spa is inoperative  
Power failure / not plugged in  
GFCI tripped  
Check power source  
Reset GFCI; call for service if it will not reset.  
Heater high-limit thermostat tripped  
Disconnect power for at least thirty seconds to reset heater high-limit. If it  
will not reset, check for clogged filter. If tripping continues, call for service.  
Spa jets and heat off,  
Pressure switch is open and should be  
closed.  
Check for clogged filter. The pressure switch will reset when the flow of  
water through the heater has been restored. Call for service if the pressure  
switch trips frequently.  
light operates  
(Display reads _ . _ . _ . _ )  
_ . _ . _ . _  
_ _ _ _  
Pressure switch senses flow through heater  
even though the jet pump is off  
Contact an Authorized Service Technician  
(Display reads _ _ _ _  
)
Control Sensor open or shorted  
Spa water level too low  
Filters clogged / Jet intake screens clogged  
Jet nozzles closed / Air valve closed  
Contact an Authorized Service Technician  
Add water  
Clean filters / Clean jet intake screens  
Open jet nozzles / Open air valve  
READY icon flashes  
Jets weak or surging  
Deactivate spa lock  
Spa lock activated  
Light inoperative  
Light wiring or assembly is faulty  
Heater high-limit thermostat tripped  
Replace light assembly  
Disconnect power to the spa for at least thirty seconds to reset the heater  
high-limit. If tripping continues, clean the filter, then if tripping still occurs,  
call for service.  
Display reads - - - -  
(Entire spa inoperative)  
Set water temperature  
significantly different from  
display temperature  
System Controls  
Contact an Authorized Service Technician  
SPA WATER MAINTENANCE TROUBLESHOOTING GUIDE  
Problem  
Probable causes  
Solutions  
Cloudy Water  
Dirty filters  
Clean filters  
Excessive oils / organic matter  
Improper sanitization  
Suspended particles / organic matter  
Overused or old water  
Shock spa with sanitizer  
Add sanitizer  
Adjust pH and/or alkalinity to recommended range  
Run jet pump and clean filter  
Drain and refill the spa  
Water Odor  
Excessive organics in water  
Improper sanitization  
Low pH  
Shock spa with sanitizer  
Add sanitizer  
Adjust pH to recommended range  
Chloramine level too high  
Low pH  
Shock spa with sanitizer  
Adjust pH to recommended range  
Chlorine Odor  
Musty Odor  
Bacteria or algae growth  
Shock spa with sanitizer – if problem is visible or persistent, drain, clean,  
and refill the spa  
Organic buildup /  
scum ring around spa  
Build-up of oils and dirt  
Wipe off scum with clean rag – if severe, drain the spa, use a spa surface  
and tile cleaner to remove the scum and refill the spa  
Algae Growth  
Eye Irritation  
Skin Irritation / Rash  
Stains  
High pH  
Low sanitizer level  
Shock spa with sanitizer and adjust pH  
Shock spa with sanitizer and maintain sanitizer level  
Low pH  
Low sanitizer level  
Adjust pH  
Shock spa with sanitizer and maintain sanitizer level  
Unsanitary water  
Free chlorine level above 5 ppm  
Shock spa with sanitizer and maintain sanitizer level  
Allow free chlorine level to drop below 5 ppm before spa use  
Total alkalinity and/or pH too low  
High iron or copper in source water  
Adjust total alkalinity and/or pH  
Use a metal deposit inhibitor  
High calcium content in water – total  
alkalinity and pH too high  
Adjust total alkalinity and pH – if scale requires removal, drain the spa,  
scrub off the scale, refill the spa and balance the water  
Scale  
Page 34  
Service Information  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Watkins Manufacturing Corporation  
Vista, California USA  
This manual contains installation, operating, maintenance and service information for the  
following 2008 Hot Spot® Spa models:  
USA MODELS  
EFFECTIVE DATE  
CANADIAN MODELS  
EFFECTIVE DATE  
LA PALMATM (MODEL LAP)  
MALLORCA® (MODEL MAL)  
SORRENTO® (MODEL SOR)  
TRINIDAD® (MODEL TRI)  
3/08  
3/08  
3/08  
3/08  
LA PALMA (MODEL LAPC )  
MALLORCA (MODEL MALC)  
SORRENTO (MODEL SORC )  
TRINIDAD (MODEL TRIC)  
3/08  
3/08  
3/08  
3/08  
©2008 Watkins Manufacturing Corporation. Hot Spot, Precision, La Palma, Mallorca, Sorrento, Trinidad, No-Fault, FreshStart,  
FreshWater, FreshWaterAg+, EverFresh, Splendors and The Home Relaxation Specialists are trademarks of Watkins Manufacturing  
Corporation. Baqua Spa is a trademark of Arch UK Biocides Limited. Windex is a trademark of S.C. Johnson & Son, Inc. Soft Scrub  
is a trademark of The Clorox Company. Brominating Concentrateis a trademark of Bio-Lab Inc. SPA FROG is a trademark of King  
Technologies Inc..  
PART #301500, REV. B (3/08)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tektronix Telescope 2232 User Manual
Texas Instruments Calculator MSP50C6xx User Manual
The Singing Machine Car Video System STVG 512 User Manual
The Speaker Company Speaker System Home Theater Speaker User Manual
Uniden Cordless Telephone EXP6900 User Manual
Uniden Marine Radio MHS050 2 User Manual
Uniden Network Router UIP1868P User Manual
USRobotics Switch NETServer 8 User Manual
Vermont Casting Indoor Fireplace DBT33 User Manual
Watlow Electric Electric Heater Responsive Heater User Manual