®
WatchGuard
V10, V60L, V60,
V80, V100
Hardware Guide
Vclass 5.0
Download from Www.Somanuals.com. All Manuals Search And Download.
VCCI Notice Class A ITE
Firebox V10, V60L, V60, V80, V100 Hardware Guide
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Declaration of Conformity
iv
Vclass
Download from Www.Somanuals.com. All Manuals Search And Download.
Firebox Limited Hardware Warranty
This Limited Hardware Warranty (the “Warranty”) applies to the enclosed
WatchGuard hardware product (the “Product”), not including any associated software
which is licensed pursuant to a seperate end-user license agreement and warranty. BY
USING THE PRODUCT, YOU AGREE TO THE TERMS HEREOF. If you do not agree
to these terms, please return this package, along with proof of purchase, to the
authorized dealer from which you purchased it for a full refund. WatchGuard
Technologies, Inc. (”WatchGuard”) and you agree as follows:
1. Limited Warranty. WatchGuard warrants that upon delivery and for one (1) year
thereafter (the “Warranty Period”): (a) the Product will be free from material defects
in materials and workmanship, and (b) the Product, when properly installed and used
for its intended purpose and in its intended operating environment, will perform
substantially in accordance with WatchGuard applicable specifications.
This warranty does not apply to any Product that has been: (i) altered, repaired or
modified by any party other than WatchGuard; or (ii) damaged or destroyed by
accidents, power spikes or similar events or by any intentional, reckless or negligent
acts or omissions of any party. You may have additional warranties with respect to the
Product from the manufacturers of Product components. However, you agree not to
look to WatchGuard for, and hereby release WatchGuard from any liability for,
performance of, enforcement of, or damages or other relief on account of, any such
warranties or any breach thereof.
2. Remedies. If any Product does not comply with the WatchGuard warranties set forth
in Section 1 above, WatchGuard will, at its option, either (a) repair the Product, or (b)
replace the Product; provided, that you will be responsible for returning the Product to
the place of purchase and for all costs of shipping and handling. Repair or replacement
of the Product shall not extend the Warranty Period. Any Product, component, part or
other item replaced by WatchGuard becomes the property of WatchGuard .
WatchGuard shall not be responsible for return of or damage to any software,
firmware, information or data contained in, stored on, or integrated with any returned
Products.
3. Disclaimer and Release. THE WARRANTIES, OBLIGATIONS AND LIABILITIES
OF WATCHGUARD, AND YOUR REMEDIES, SET FORTH IN PARAGRAPHS 1 AND
2 ABOVE ARE EXCLUSIVE AND IN SUBSTITUTION FOR, AND YOU HEREBY
WAIVE, DISCLAIM AND RELEASE ANY AND ALL OTHER WARRANTIES,
OBLIGATIONS AND LIABILITIES OF WATCHGUARD AND ALL OTHER RIGHTS,
CLAIMS AND REMEDIES YOU MAY HAVE AGAINST WATCHGUARD, EXPRESS
OR IMPLIED, ARISING BY LAW OR OTHERWISE, WITH RESPECT TO ANY
NONCONFORMANCE OR DEFECT IN THE PRODUCT (INCLUDING, BUT NOT
LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE, ANY IMPLIED WARRANTY ARISING FROM
COURSE OF PERFORMANCE, COURSE OF DEALING, OR USAGE OF TRADE,
ANY WARRANTY OF NONINFRINGEMENT, ANY WARRANTY OF
UNINTERRUPTED OR ERROR-FREE OPERATION, ANY OBLIGATION,
LIABILITY, RIGHT, CLAIM OR REMEDY IN TORT, WHETHER OR NOT ARISING
FROM THE NEGLIGENCE (WHETHER ACTIVE, PASSIVE OR IMPUTED) OR
FAULT OF WATCHGUARD OR FROM PRODUCT LIABILITY, STRICT LIABILITY
OR OTHER THEORY, AND ANY OBLIGATION, LIABILITY, RIGHT, CLAIM OR
REMEDY FOR LOSS OR DAMAGE TO, OR CAUSED BY OR CONTRIBUTED TO
BY,THE PRODUCT).
4. Limitation of Liability. WATCHGUARD TECHNOLOGIES’ LIABILITY (WHETHER
ARISING IN CONTRACT (INCLUDING WARRANTY), TORT (INCLUDING ACTIVE,
PASSIVE OR IMPUTED NEGLIGENCE AND STRICT LIABILITY AND FAULT) OR
OTHER THEORY) WITH REGARD TO ANY PRODUCT WILL IN NO EVENT
EXCEED THE PURCHASE PRICE PAID BY YOU FOR SUCH PRODUCT. THIS
SHALL BE TRUE EVEN IN THE EVENT OF THE FAILURE OF ANY AGREED
REMEDY. IN NO EVENT WILL WATCHGUARD TECHNOLOGIES BE LIABLE TO
Firebox V10, V60L, V60, V80, V100 Hardware Guide
v
Download from Www.Somanuals.com. All Manuals Search And Download.
YOU OR ANY THIRD PARTY (WHETHER ARISING IN CONTRACT (INCLUDING
WARRANTY), TORT (INCLUDING ACTIVE, PASSIVE OR IMPUTED NEGLIGENCE
AND STRICT LIABILITY AND FAULT) OR OTHER THEORY) FOR COST OF COVER
OR FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES (INCLUDING WITHOUT LIMITATION LOSS OF PROFITS, BUSINESS,
OR DATA) ARISING OUT OF OR IN CONNECTION WITH THIS WARRANTY OR
THE USE OF OR INABILITY TO USE THE PRODUCT, EVEN IF WATCHGUARD
TECHNOLOGIES HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. THIS SHALL BE TRUE EVEN IN THE EVENT OF THE FAILURE OF
ANY AGREED REMEDY.
5. Miscellaneous Provisions. This Warranty will be governed by the laws of the state of
Washington, U.S.A., without reference to its choice of law rules. The provisions of the
1980 United Nations Convention on Contracts for the International Sales of Goods, as
amended, shall not apply. You agree not to directly or indirectly transfer the Product or
associated documentation to any country to which such transfer would be prohibited by
the U.S. Export laws and regulations. If any provision of this Warranty is found to be
invalid or unenforceable, then the remainder shall have full force and effect and the
invalid provision shall be modified or partially enforced to the maximum extent
permitted by law to effectuate the purpose of this Warranty. This is the entire
agreement between WatchGuard and you relating to the Product, and supersedes any
prior purchase order, communications, advertising or representations concerning the
Product AND BY USING THE PRODUCT YOU AGREE TO THESE TERMS. No
change or modification of this Agreement will be valid unless it is in writing, and is
signed by WatchGuard.
Notice to Users
Information in this guide is subject to change without notice. Companies, names, and
data used in examples herein are fictitious unless otherwise noted. No part of this guide
may be reproduced or transmitted in any form or by any means, electronic or
mechanical, for any purpose, without the express written permission of WatchGuard
Technologies, Inc.
Copyright, Trademark, and Patent Information
Copyright© 1998 - 2003 WatchGuard Technologies, Inc. All rights reserved.
AppLock®, AppLock®/Web, Designing peace of mind®, Firebox®, Firebox® 1000,
Firebox® 2500, Firebox® 4500, Firebox® II, Firebox® II Plus, Firebox® II
FastVPN, Firebox® III, Firebox® SOHO, Firebox® SOHO 6, Firebox® SOHO 6tc,
Firebox® SOHO|tc, Firebox® V100, Firebox® V80, Firebox® V60, Firebox V60L,
Firebox® V10, LiveSecurity®, LockSolid®, RapidStream®, RapidCore®,
ServerLock®, WatchGuard®, WatchGuard® Technologies, Inc., DVCP™ technology,,
Enforcer/MUVPN™, FireChip™, HackAdmin™, HostWatch™, Make Security Your
Strength™, RapidCare™, SchoolMate™, ServiceWatch™, Smart Security. Simply
Done.™, Vcontroller™, VPNforce™ are either registered trademarks or trademarks of
WatchGuard Technologies, Inc. in the United States and/or other countries.
© Hi/fn, Inc. 1993, including one or more U.S. Patents: 4701745, 5016009,
5126739, and 5146221 and other patents pending.
Microsoft®, Internet Explorer®, Windows® 95, Windows® 98, Windows NT® and
Windows® 2000 are either registered trademarks or trademarks of Microsoft
Corporation in the United States and/or other countries.
Netscape and Netscape Navigator are registered trademarks of Netscape
Communications Corporation in the United States and other countries.
vi
Vclass
Download from Www.Somanuals.com. All Manuals Search And Download.
RC2 Symmetric Block Cipher, RC4 Symmetric Stream Cipher, RC5 Symmetric Block
Cipher, BSAFE, TIPEM, RSA Public Key Cryptosystem, MD, MD2, MD4, and MD5
are either trademarks or registered trademarks of RSA Data Security, Inc. Certain
materials herein are Copyright © 1992-1999 RSA Data Security, Inc. All rights
reserved.
RealNetworks, RealAudio, and RealVideo are either a registered trademark or
trademark of RealNetworks, Inc. in the United States and/or other countries.
Java and all Jave-based marks are trademarks or registered trademarks of Sun
Microsystems, Inc. in the United States and other countries. All right reserved.
© 1995-1998 Eric Young (eay@cryptsoft). All rights reserved.
© 1998-2000 The OpenSSL Project. All rights reserved. Redistribution and use in
source and binary forms, with or without modification, are permitted provided that the
following conditions are met:
1. Redistributions of source code must retain the above copyright notice, this list of
conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright notice, this list of
conditions and the following disclaimer in the documentation and/or other materials
provided with the distribution.
3. All advertising materials mentioning features or use of this software must display
the following acknowledgment: "This product includes software developed by the
OpenSSL Project for use in the OpenSSL Toolkit. (http://www.openssl.org/)"
4. The names "OpenSSL Toolkit" and "OpenSSL Project" must not be used to endorse or
promote products derived from this software without prior written permission. For
written permission, please contact [email protected].
5. Products derived from this software may not be called "OpenSSL" nor may
"OpenSSL" appear in their names without prior written permission of the OpenSSL
Project.
6. Redistributions of any form whatsoever must retain the following acknowledgment:
"This product includes software developed by the OpenSSL Project for use in the
OpenSSL Toolkit (http://www.openssl.org/)"
THIS SOFTWARE IS PROVIDED BY THE OpenSSL PROJECT ``AS IS'' AND ANY
EXPRESSED OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
OpenSSL PROJECT OR ITS CONTRIBUTORS BE LIABLE FOR ANY DIRECT,
INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR
BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF
LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING
NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
This product includes cryptographic software written by Eric Young
Hudson ([email protected]).
All rights reserved.
The implementation was written so as to conform with Netscapes SSL.
This library is free for commercial and non-commercial use as long as the following
conditions are aheared to. The following conditions apply to all code found in this
distribution, be it the RC4, RSA, lhash, DES, etc., code; not just the SSL code. The
SSL documentation included with this distribution is covered by the same copyright
terms except that the holder is Tim Hudson ([email protected]).
Copyright remains Eric Young's, and as such any Copyright notices in the code are not
to be removed. If this package is used in a product, Eric Young should be given
attribution as the author of the parts of the library used. This can be in the form of a
Firebox V10, V60L, V60, V80, V100 Hardware Guide
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
textual message at program startup or in documentation (online or textual) provided
with the package. Redistribution and use in source and binary forms, with or without
modification, are permitted provided that the following conditions are met:
1. Redistributions of source code must retain the copyright notice, this list of conditions
and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright notice, this list of
conditions and the following disclaimer in the documentation and/or other materials
provided with the distribution.
3. All advertising materials mentioning features or use of this software must display
the following acknowledgement: "This product includes cryptographic software written
routines from the library being used are not cryptographic related :-).
4. If you include any Windows specific code (or a derivative thereof) from the apps
directory (application code) you must include an acknowledgement: "This product
includes software written by Tim Hudson ([email protected])"
THIS SOFTWARE IS PROVIDED BY ERIC YOUNG ``AS IS'' AND ANY EXPRESS
OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY,
WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING
NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
The licence and distribution terms for any publicly available version or derivative of
this code cannot be changed. i.e. this code cannot simply be copied and put under
another distribution licence [including the GNU Public Licence.]
All other trademarks or trade names mentioned herein, if any, are the property of their
respective owners.
Part No: 1194-000
viii
Vclass
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Front and Back Views .......................................................3
The Firebox V10 model ..................................................3
The Firebox V60, V60L and V80 models .............................5
The Firebox V100 model .................................................8
Firebox V10, V60, V60L, V80, and V100 Components .......11
Index
.......................................................................13
Firebox V10, V60L, V60, V80, V100 Hardware Guide
ix
Download from Www.Somanuals.com. All Manuals Search And Download.
x
Vclass
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 1
Hardware
Descriptions
This chapter provides a visual tour of the external
hardware features of the WatchGuard® Firebox® V10,
V60, V80, and V100 security appliances, focusing on
the buttons, LEDs, interfaces, ports. Please see the Fire-
box Vclass User Guide for installation instructions.
Package Contents
Each appliance model is packaged with different con-
tents, as described in this section.
WatchGuard Firebox V10 security appliance
•
One 12V 1.25A, power supply
•
Two green, straight-through, 10/100 BaseT,
Ethernet cables
•
A CD containing the WatchGuard Vcontroller
application software for use with three different
operating systems: Windows 2000/XP, Solaris,
Firebox V10, V60L, V60, V80, V100 Hardware Guide
1
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 1: Hardware Descriptions
and Linux. The CD also provides electronic versions of
the complete user documentation set.
WatchGuard Firebox V60, V60L, and V80
security appliance
•
•
•
One power cord
One red, crossover 10/100 BaseT Ethernet cable
Three green, straight-through, 10/100 BaseT, Ethernet
cables
•
•
•
One console, RJ 45-to-RJ 45, serial cable and DB-9
adapter
One APC-manufactured, appliance-to-UPS device
cable
A CD containing the WatchGuard Vcontroller
application software for use with three different
operating systems: Windows 2000/XP, Solaris, and
Linux. The CD also provides electronic versions of the
complete user documentation set.
•
Rack-mounting hardware. If you are mounting the
appliance in a rack, note that Firebox V60L, V60, and
V80 appliances are 1U high.
WatchGuard Firebox V100 security
appliance
•
•
•
One power cord
One red, crossover, 10/100 BaseT, Ethernet cable
One green, straight-through, 10/100 BaseT, Ethernet
cable
•
•
Two optical, data cables
One APC-manufactured, appliance-to-UPS device
cable
•
•
One console, RJ 45-to-RJ 45, serial cable and DB-9
adapter
A CD containing the WatchGuard Vcontroller
application software for use with three different
2
Vclass
Download from Www.Somanuals.com. All Manuals Search And Download.
Front and Back Views
operating systems: Windows 2000/XP, Solaris, and
Linux. The CD also provides electronic versions of the
complete user documentation set.
•
Rack-mounting hardware. If you are mounting the
appliance in a rack, note that the Firebox V100 is 1 U
high.
Front and Back Views
The Firebox V10 model
The front panel of a Firebox V10 appliance contains the
indicators shown in the following illustration.
Alarm
Admin
Ready
Power
The LEDs on the front panel are as follows:
Power
Illuminates when the appliance has been turned
on.
Ready
Blinks when the appliance is powering up.
Illuminates when the appliance is ready for
network traffic.
Firebox V10, V60L, V60, V80, V100 Hardware Guide
3
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 1: Hardware Descriptions
Alarm
Illuminates when certain alarms are triggered. For
more information on alarms, see the Firebox Vclass
User Guide.
Admin
Illuminates when a system administrator is
connected to the appliance by means of the
Vcontroller or the WatchGuard CLI.
The back panel of a Firebox V10 appliance contains the
interfaces and ports shown in the following illustration.
1 (Public)
0 (Private)
Console
Power
0 (Private) and 1 (Public)
Two Ethernet interfaces (RJ-45 connectors) labeled
0 and 1, act as the primary data interfaces.
Incorporated into each Ethernet interface are two
indicator lights labeled 10 and 100. These LEDs
indicate the speed of traffic being transmitted.
Console
A single RJ-45 interface permits a direct
workstation-to-appliance connection. You can use
the WatchGuard Command Line Interface (CLI) to
configure and administer this appliance. For more
information about this administrative option, see
the CLI Guide.
4
Vclass
Download from Www.Somanuals.com. All Manuals Search And Download.
Front and Back Views
Power Port
This interface serves as the connection to a
100VAC-to-240VAC (50/60Hz) source. Use the
power cord supplied in the package to connect this
appliance to a UPS device or to a power outlet. The
power supply can auto-detect 110/220 voltage.
NOTE
Always connect the power cable to the power port on the
back of the V10 before you connect it to the AC outlet.
NOTE
In the event of a power failure, this security appliance, if left
connected to the power source, automatically restarts itself
after electrical power has been restored. You do not have to
unplug and then reconnect the appliance to the power source.
The Firebox V60, V60L and V80 models
The front panels of the Firebox V60, V60L, and V80 security
appliances contain the features shown in the following
illustration.
Accelerated Ethernet
Interfaces
0 (Private)
Console Interface
1 (Public)
Ready
Admin
Alarm
2 (DMZ)
3 (DMZ)
Power LED
100
10 100
10 100
10 100
10
100
10
100
10
Ready
Admin
Alarm
Power
HA
0
1
2
3
HA2
HA1
Console
Reset
Reset port
High Availability
Status LED
High Availability
(HA Interface)
Accelerated Ethernet Interfaces
Four accelerated, Ethernet interfaces (RJ-45
connectors) labeled 0 (Private), 1 (Public), 2 (DMZ1),
and 3 (DMZ2) act as the primary conduits through
which passes all of the network data traffic.
Incorporated into each interface are two indicator
Firebox V10, V60L, V60, V80, V100 Hardware Guide
5
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 1: Hardware Descriptions
lights labeled 10 and 100. These LEDs indicate the
speed of traffic being transmitted.
High Availability Status LED
Indicates the current status of this appliance, if it is
one of two connected as a high-availability system.
If this is the primary appliance, and the light is on
and steady, the system is functional, and this
appliance is on-line. If this is the primary appliance
and the LED is blinking, a failover has occurred
and the secondary appliance is online.
High Availability Interfaces
Two Ethernet interfaces, labelled HA2 and HA1
enable you to connect with a cross-over Ethernet
cable to other High Availability-ready Firebox
Vclass appliances for failover (backup) protection.
Incorporated into the two high-availability
Ethernet ports are two indicator lights labeled 10
and 100. These LEDs indicate the speed traffic is
transmitted.
Console Interface
A single RJ-45 interface, labeled Console, permits a
direct workstation-to-appliance connection. You
can use the WatchGuard Command Line Interface
(CLI) to configure and administer this appliance.
For more information about this administrative
option, see the CLI Guide.
Ready
Blinks when the appliance is powering up.
Illuminates when the appliance is ready for
network traffic.
Admin
Illuminates when a system administrator is
connected to the appliance by means of the
Vcontroller or the WatchGuard CLI.
6
Vclass
Download from Www.Somanuals.com. All Manuals Search And Download.
Front and Back Views
Alarm
Illuminates when certain alarms are triggered. For
more information on alarms, see the Firebox Vclass
User Guide.
Reset port
This opening allows you to insert a straight pin or
paperclip and press an internal reset switch that
restarts the appliance.
Power LED
Illuminates when the appliance has been turned
on.
The back panel of a Firebox V60, V60L, or V80 contains the
features shown in the following illustration.
Power supply switch
AC Power cord
"UPS" port
AC Power Cord
Enables you to connect the appliance (using the
supplied power cord) to a 100 to 240VAC (50/
60Hz) power source.
NOTE
Do not connect Firebox Vclass appliance to a source of power
that supplies the wrong voltage. Doing so will damage the
appliance and void the warranty.
Power Supply Switch
Allows you to turn the appliance on or off.
UPS Port
Permits connection of the appliance to an
Uninterruptable Power Supply (UPS). This type of
connection enables UPS devices to notify the
Firebox V10, V60L, V60, V80, V100 Hardware Guide
7
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 1: Hardware Descriptions
appliance if the power goes out, prompting the
appliance to shut itself down properly.
UPS devices from American Power Company
(APC) are currently supported by the Firebox
Vclass power management firmware. Check the
updated information on complete UPS support.
NOTE
In the event of a power failure, this security appliance, if left
connected to the power source, will automatically restart
itself after electrical power has been restored. You do not
have to press either the Power button on the front or the
power supply switch on the back of the appliance.
The Firebox V100 model
The front panel of the Firebox V100 security appliance con-
tains the features shown in the following illustration.
1 (Public)
0 (Private)
Console Interface
Ready
Rx
Tx
Rx
Tx
Admin
Power LED
Link
Alarm
Link
100
10
100
10
Rx
Tx
Rx
Tx
Ready
Admin
Alarm
Power
Link
Link
HA2
HA1
Console
Reset
HA
Reset port
High Availability
Status LED
High Availability
(HA Interface)
Gigabit interfaces
Two Gigabit Ethernet interfaces, labeled 0 and 1
(corresponding to Private and Public), act as the
primary conduits through which network traffic
8
Vclass
Download from Www.Somanuals.com. All Manuals Search And Download.
Front and Back Views
passes. These interfaces are multi-mode, but they
do not support 10/100 communications.
On each side of the two Gigabit interfaces are three
LEDs labeled RX, TX, and Link.
The Link LED is lit when a connection is active.
The RX LED blinks steadily when data packets are
being received by the appliance.
The TX LED blinks steadily when data packets are
being transmitted.
High Availability Status LED
Indicates the current status of this appliance, if it is
one of two connected as a high-availability system.
If this is the primary appliance, and the light is on
and steady, the system is functional, and this
appliance is online. If this is the primary appliance
and the LED is blinking, a failover has occurred
and the secondary appliance is online.
For more information on HA setup, see the Firebox
Vclass User Guide.
High Availability Interfaces
Two Ethernet interfaces, labelled HA2 and HA1
enable you to connect with a cross-over Ethernet
cable to other High Availability-ready Firebox
Vclass appliances for failover (backup) protection.
Incorporated into the two high-availability
Ethernet ports are two indicator lights labeled 10
and 100. These LEDs indicate the speed traffic is
transmitted.
Console Interface
A single RJ-45 interface, labelled Console, supports
a direct workstation-to-appliance connection. You
can use the WatchGuard Command Line Interface
(CLI) to administer and test this appliance. To learn
more about this administrative option, see the CLI
Guide included on the installer CD.
Firebox V10, V60L, V60, V80, V100 Hardware Guide
9
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 1: Hardware Descriptions
Ready
Blinks when the appliance is powering up or
powering down. It is steadily lit when the
appliance is ready for network traffic.
Admin
Illuminates when a user or system administrator is
connected to the Firebox Vclass appliance by
means of the Vcontroller or the WatchGuard CLI.
Alarm
Indicates when an alarm is activated. For more
information on alarms, see the Firebox Vclass User
Guide.
Reset Port
Allows you to insert a straight pin or paperclip and
press an internal Reset switch that restarts the
appliance. This is an alternative to unplugging and
replugging the power cord.
Power LED
Indicates whether the appliance has been fully
turned on and is ready for administration or use.
The back panel of a Firebox V100 includes the features
shown in the following illustration.l
Power supply switch
AC power cord
"UPS" port
NOTE
Do not connect any Firebox Vclass appliance to a source of
power that supplies the wrong voltage. Doing so will damage
the appliance and void the warranty.
10
Vclass
Download from Www.Somanuals.com. All Manuals Search And Download.
Firebox V10, V60, V60L, V80, and V100 Components
AC Power Cord
Enables you to connect the appliance (using the
supplied power cord) to a 100 to 240VAC (50/
60Hz) power source. The power supply can auto-
detect 110/220 voltage.
Power Supply Switch
Allows you to turn the appliance on or off.
UPS Port
Allows you to use the RS-232 cable provided in the
package to connect the appliance to an
Uninterruptable Power Supply (UPS). This type of
connection enables UPS devices to notify the
appliance if the power goes out, prompting the
appliance to shut itself down properly.
UPS devices from American Power Company
(APC) are currently supported by the Firebox
Vclass power management firmware. Check the
updated information on complete UPS support.
NOTE
In the event of a power failure, this security appliance, if left
connected to the power source, will automatically restart
itself after electrical power has been restored. You do not
have to press either the Power button on the front or the
power supply switch on the back of the appliance.
Firebox V10, V60, V60L, V80, and V100
Components
Every appliance has three sets of components:
RapidCore™ hardware ensemble
A well-integrated chip set and memory system
powers every Firebox Vclass appliance in its
Firebox V10, V60L, V60, V80, V100 Hardware Guide
11
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 1: Hardware Descriptions
primary duties: protecting your network and
efficiently managing all legitimate data streams.
WatchGuard Firebox Vclass Operating System™ (OS)
Every Firebox Vclass security appliance is
preinstalled with the latest version of the Firebox
Vclass Operating System–which is identified on
the packaging by a version number. This operating
system includes all the software resources that
make the appliance fully functional.
WatchGuard Firebox Vclass administrative client
applications
The WatchGuard Vcontroller (or the companion
WatchGuard CPM client software) gives you full
control of all the customizable operating system
parameters, including basic system configurations,
security policies, maintenance, and activity
logging.
If you already have one or more operational Firebox Vclass
appliances in your network, you can shortcut the installa-
tion and configuration process on a new factory-default
appliance. First, export a complete configuration file from
an operational appliance and then import it into the new
appliance. After this is done, you can change a few key set-
tings and have a fully functional appliance in location and
ready for use. For more information, see Firebox Vclass User
Guide.
NOTE
This manual refers to the accelerated data interfaces
interchangeably as Private, Public, and (where available)
DMZ or with the standard interface numbering (0, 1, etc.):
0 = Private, 1 = Public, 2&3 = DMZ
Where other interfaces are included (a second DMZ or High
Availability), the corresponding interface numbering will be
noted at that time.
12
Vclass
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
LEDs
Admin 4, 6, 10
Alarm 4, 7, 10
Ready 3, 6, 10
A
AC power 7, 11
Admin LED 4, 6, 10
Alarm LED 4, 7, 10
P
C
Power switch 7, 11
certification, FCC ii
Console interface 4, 6, 9
E
Ethernet interfaces
RapidCore hardware ensemble 11
for Firebox V10 4
for Firebox V100 8
for Firebox V60 and V80 5
F
FCC certification ii
Firebox V10
UPS interface
back panel 4
Firebox Vclass 100 11
front panel 3
package contents 1
Firebox V100
back panel 10
V
package contents 2
Firebox V60, V60L, V80
back panel 7
described 12
package contents 2
Firebox Vclass Operating System 12
Fireboxes
components of 11
W
WatchGuard Vcontroller 12
H
HA interfaces 6, 9
HA status LED 6, 9
Firebox V10, V60L, V60, V80, V100 Hardware Guide
13
Download from Www.Somanuals.com. All Manuals Search And Download.
|