Vinotemp Refrigerator VINO2500SSD User Manual

VINO2500SSD, 4500SSD  
VINO6500SSD, 8500SSD  
Installer’s Instruction  
Federal law requires that WINE-MATE split cooling systems be  
installed by an EPA certified refrigeration technician.  
WINE-MATE split system is shipped as components and is ready for use only  
after a certified refrigeration technician has properly installed, chatged and tested  
the system. Proper installation is critical. Vinotemp can only warrant the quality of  
the components. The installation and proper operation of the system must be  
warranted by the installer. Installation of the system must be done in accordance  
with all state and local building codes.  
The condensing unit and evaporator unit are connected by a liquid line and an  
insulated suction line that are supplied by the installer. These lines must be  
properly sized for the distance between the two units. After the units and the lines  
are installed, the system must be pressure tested. If no leaks are found,  
evacuate and charge system with R134A. Refrigerant amount will vary  
depending on the length of line set.  
1. Condensing Unit  
Place the condensing units WM250-850SCU in a properly ventilated  
location. If it is not, heat exhausted by the condensing unit will build up  
and the cooling system will not operate properly.  
Leave minimum 5 feet clearance for the exhaust side and leave minimum  
1 foot clearance for the fresh air intake side.  
Condensing unit shall be elevated to avoid possible flooding and shaded  
from direct sun. It shall not be exposed to temperatures higher than 110  
°F or lower than 45 °F (optional low ambient kit for 20 °F).  
2. Evaporator Unit  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Pressure, Superheat and Subcooling Readings  
NOTES: THE VALVES MUST BE IN THE MIDDLE POSITIONS TO READ  
PROPERLY.  
Complaint  
Possible Causes  
a. Compressor may be bad  
b. Expansion valve opened, too  
much oil  
a. High suction pressure and low head pressure  
b. High suction pressure and low head pressure  
Low superheat and low subcooling  
c. High suction pressure and high head pressure  
Low superheat and high subcooling  
c. Overcharge  
d. High to normal suction pressure and high head pressure d. Non-condensable gas  
Low subcooling  
e. High suction pressure and high head pressure  
Low subcooling  
f. High suction pressure and high head pressure  
High superheat  
e. Air restricted, dirty condenser,  
bad condenser fans  
f. High room temperature, high  
evaporator load  
g. Low suction pressure and low head pressure  
High superheat and low subcooling  
g. Undercharge  
h. Low suction pressure and low to normal head pressure  
High superheat and high subcooling  
h. Liquid line restricted after  
receiver,  
restricted  
solenoid  
valve  
i. Low suction pressure and low head pressure  
Low subcooling  
i. Suction line restricted  
j. Low suction pressure and low head pressure  
Low superheat and low subcooling  
j. Air restricted at evaporator,  
evaporator iced  
k. Low suction pressure and low to normal head pressure  
High superheat and normal to high subcooling  
l. Low suction pressure and normal head pressure  
High superheat and normal subcooling  
k. Evaporator restricted  
l. Expansion valve restricted  
m. Low suction pressure and high head pressure  
High superheat and high subcooling  
m. Both evaporator and condenser  
restricted  
n. Low suction pressure and high head pressure  
High superheat and high subcooling  
n. Liquid line restricted before  
receiver  
o. low to normal suction pressure and high head pressure  
High to normal superheat and high subcooling  
o. Condenser restricted  
6. Valve Operation  
SPINDLE BACK POSITION SPINDLE FRONT POSITION SPINDLE MIDDLE POSITION  
Fig. 2.1 Valve Operation  
- 2 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Back Position: Process and manometer port closed for normal operation  
Front Position: Main connection to liquid or suction line closed  
Middle Position: All ports open for vacuum, charge and measurement  
7. Electrical Wiring  
Fig. 2.2 VINO2500 & 4500SSD Electrical Wiring Diagram (VTSTAT)  
Fig. 2.3 VINO2500 & 4500SSD Wiring Diagram (DIGITAL CONTROLLER)  
- 3 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig. 2.4 VINO6500SSD Electrical Wiring Diagram (VTSTAT)  
Fig. 2.5 VINO6500SSD Electrical Wiring Diagram (DIGITAL CONTROLLER)  
- 4 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig. 2.6 VINO8500SSD Electrical Wiring Diagram (VTSTAT, UJ6220Z)  
Fig. 2.7 VINO8500SSD Wiring Diagram (DIGITAL CONTROLLER, UJ6220Z)  
- 5 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Use of the adjustable low pressure control (if applicable)  
Cut out = 5 psig; Cut in = 25 psig; Differential = 20 psig  
It may need to adjust the setting in the field to get the right cycle time.  
8.1 P70AB-12  
Fig. 2.8 P70AB-12 Adjustable Low Pressure Control  
8.2 PS2-A7A  
Fig. 2.9 PS2-A7A Adjustable Dual Pressure Control  
- 6 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig. 3.0 PS2-A7A Wiring Diagram  
9. Condensing Unit Troubleshooting  
Unit not running  
a. Incorrect power supply  
b. Incorrect or loose wirings  
c. Failed components  
a. Check for proper voltage  
b. Check all wirings and connections  
c. Check start relay, start capacitor, overload  
protector, compressor.  
d. Liquid refrigerant in the compressor  
e. Low pressure switch shutting down the unit  
d. Call service for OEM information  
e. Check for system restriction or low  
refrigerant  
- 7 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Technicolor Thomson DVD Player DPL914VD User Manual
Texas Instruments Stereo Amplifier TPA3001D1EVM User Manual
Texas Instruments Switch TNETX3270 User Manual
Tripp Lite TV Cables S244 000 User Manual
Troy Bilt Snow Blower 42051 User Manual
U Line Beverage Dispenser 2275DWRWOL User Manual
Uniden Cordless Telephone EXS 9800 User Manual
VocoPro Microphone IR 9000 User Manual
VTech Cordless Telephone 6032 User Manual
VTech Pet Fence learn to write with cody cora innotab User Manual