IONPS-A, AC Power Module  
Description — continued  
Notices  
Description  
Transition Networks’ IONPS-A, AC Power Module can deliver power or provide  
optional, redundant AC power to an ION219-A chassis. See the ION219-A chassis  
manual #33421. You can download the manual @ www.transition.com, then click on  
Product/Product Finder.  
The IONPS-A, AC Power Module must be installed by qualified technical  
personnel only. Transition networks assumes no responsibility for the improper  
installation, set up, or use of the IONPS-A, AC Power Module.  
The information in this user’s guide is subject to change. For the most up-to-date  
information, see the user’s guide on-line to download the current version of the  
manual at www.transition.com under Products.  
Power Module component identification  
See Figure 1:  
1
2
3
4
5
6
7
Fans (two fans exhaust warm air from the IONPS-A, AC Power Module)  
Power LED (ON green when powered up)  
ON/OFF switch, when in the ON position power is supplied to the ION chassis  
Fuse (inline AC)  
Installation  
IMPORTANT  
All installation and service must be performed by qualified personnel only.  
Read, understand, and follow all CAUTION and WARNING notices, instructions  
marked on the product, including in this manual.  
Handle  
AC Power Receptacle for an AC power plug  
Dry Contact Relay (optional)  
The IONPS-A, AC Power Module can replace an existing IONPS-A, AC Power  
Module or it can be installed as the redundant Power Module in an AC powered  
ION219-A chassis.  
Note: The IONPS-A, AC Power Module has instant failover capability.  
CAUTION: While installing or servicing the Power Module, wear a grounding  
device and observe all electrostatic discharge precautions. Failure to observe this  
caution could result in damage or failure of the Power Module.  
Power module redundancy  
The IONPS-A, AC Power Module includes Instant Fail-Over (IFO) circuitry that  
provides the capability for the primary Power Module to power the chassis backplane  
while the auxiliary Power Module is in ‘hot’ standby mode. If the IFO circuitry detects  
the loss of primary power, the auxiliary Power Module instantly provides power to the  
chassis backplane. When primary power is restored, the IFO circuitry places the  
auxiliary Power Module in ‘hot’ standby mode. The chassis primary Power Module is  
located in the left slot of the chassis as viewed from the rear. The chassis auxiliary  
Power Module is located in the right slot of the chassis as viewed from the rear. A  
single Power Module placed in either location can power the chassis backplane.  
1
2
3
Note: The IONPS-A, AC Power Modules DO NOT load share.  
4
5
6
1
7
Figure 1: Power Module Components  
5
Tech Support: 1-800-260-1312 – International: 00-1-952-941-7600 – (24 hours)  
[email protected] – Click the “Transition Now” link for a live Web chat.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
IONPS-A, AC Power Module  
Installation — Continued  
Installation — Continued  
Installing an optional Power Module into the ION chassis  
Installing an optional Power Module into the ION chassis — continued  
WARNING: Do not connect the Power Module to an external power source before  
installing it into the chassis. Failure to observe this warning could result in an  
electrical shock.  
2. If necessary, remove the grounding hardware from the chassis before installing or  
removing the Power Module. See Figure 3.  
Chassis  
Grounding  
Posts  
Note: The Power Module is hot swappable (i.e., swapped while the chassis is in  
operation) provided the ON/OFF switch of the Power Module is in the OFF  
position, and it has been disconnected from its external power source.  
To install the Power Module in the ION chassis, do the following:  
Note: The procedure is the same for installing the Power Module into either slot.  
1. Push the Power Module ON/OFF switch to the OFF position. See Figure 2.  
Kepsnuts  
(provided)  
Power Module  
Switch OFF Position  
Compression Lugs  
(Not Provided )  
Figure 3: Chassis Grounding Hardware  
3. Remove the slot cover from the right chassis slot and keep the two screws. See  
Figure 4.  
Figure 2: Power ON/OFF Switch  
Screws  
Figure 4: Chassis Slot Cover  
7
Tech Support: 1-800-260-1312 – International: 00-1-952-941-7600 – (24 hours)  
[email protected] – Click the “Transition Now” link for a live Web chat.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
IONPS-A, AC Power Module  
Installation — Continued  
Installing an optional Power Module into the ION chassis — continued  
Installation — Continued  
Installing an optional Power Module into the ION chassis — continued  
4. Position the Power Module at the chassis slot, as shown in Figure 5.  
6. Insert the two screws to mount the Power Module to the chassis.  
Connecting the Power Module to external power  
To connect external power to the IONPS-A, AC Power Module, do the following:  
Chassis  
1. Locate the power cord for the Power Module.  
2. Make sure that the Power Module ON/OFF switch is in the OFF position. See  
Figure 7.  
3. Plug the female end of the AC power cord into the AC power receptacle on the  
Power Module. See Figure 7.  
4. Plug the male end of the AC power cord into the AC power source.  
5. Turn the power ON/OFF switch to the ON position. See Figure 7.  
Note: Once the power ON/OFF switch is in the ON position, the power ON LED  
will lite. This means that the optional Power Module is ready to power the  
chassis if the primary Power Module fails.  
Power Module  
Important: There is NO power sharing between the two Power Modules.  
Mounting Screws  
Power Module  
Power Cord  
Receptacle  
Power Module  
ON/OFF Switch  
Figure 5: Power Module Installation  
5. Side the Power Module completely into the chassis. See Figure 6.  
AC Power Cord  
(female end)  
AC Power Cord  
(male end)  
Chassis  
Figure 7: AC Power Cord Ends  
Installed Optional  
Power Module  
Figure 6: Power Module Installation  
Note: Once the optional Power Module is seated to the backplane of the chassis,  
the fans will become operational.  
9
Tech Support: 1-800-260-1312 – International: 00-1-952-941-7600 – (24 hours)  
[email protected] – Click the “Transition Now” link for a live Web chat.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
IONPS-A, AC Power Module  
Maintenance  
Maintenance — Continued  
Installing the Power Module — continued  
6. Locate the new Power Module.  
7. Push the power ON/OFF switch to the OFF position.  
8. Position the Power Module at the chassis slot, as shown in Figure 10.  
Replacing the Power Module  
WARNING: Do not connect the Power Module to the external power source before  
installing it into the chassis. Failure to observe this caution could result in equipment  
damage and/or personal injury or death.  
To replace the Power Module, do the following:  
1. Turn the power ON/OFF switch to the OFF position.  
2. Disconnect the AC power cord from the power source.  
3. In necessary, remove the chassis grounding assembly. See Figure 8.  
Chassis  
Chassis  
Frame  
Guide  
Nuts & Washers  
Grounding Terminal  
(Not Provided)  
Lug (Not Provided)  
Power  
Module  
Mounting Screws  
Figure 8: Chassis Grounding Hardware  
4. Remove the two screws securing the Power Module to the chassis.  
5. Carefully pull the Power Module from the chassis. See Figure 9.  
Figure 10: Power ON/OFF Switch  
9. Slide the Power Module complete into the slot.  
11. Insert the two screws to secure the Power Module to the chassis.  
12. Plug the AC power cord into the AC receptacle on the Power Module.  
13. Plug the other end of the cord into an external AC power source.  
Chassis  
14. Push the power ON/OFF switch to the ON position. The power ON LED  
should be lit and the fans will be operational.  
Mounting Screws  
Power Module  
Figure 9: Removing Power Module  
11  
Tech Support: 1-800-260-1312 – International: 00-1-952-941-7600 – (24 hours)  
[email protected] – Click the “Transition Now” link for a live Web chat.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IONPS-A, AC Power Module  
Maintenance — Continued  
Replacing the fuse  
CAUTION: Ensure that the IONPS-A, AC Power Module has been disconnected from  
the external power source and the ON/OFF switch is at “0.” Failure to observe this  
caution could result in damage or failure of the Power Module.  
Technical Specification  
For use with Transition Networks Model IONPS-A, AC Power Module.  
Dimensions:  
Weight:  
8.3" x 8.4" x 2.7" (211 mm x 211 mm x 69 mm)  
4 lb. (6.35 kg) approximately  
Power Input:  
100-240 V, 47/63Hz, 2.35 – 1.1 Amp  
(typical with a fully-loaded chassis)  
To replace the fuse in the IONPS-A, AC Power Module:  
Voltage Tolerance:  
Low-Line Input Current: 3.5A max.  
10%  
1. Ensure the ON/OFF switch on the Power Module is in the OFF position.  
2. Disconnect the AC power cord from the external power source.  
Inrush Current:  
Transient Recovery Time: 1ms max.  
13A max. ( peak starting current) @ high line  
3. Insert a small flat blade screwdriver into the groove on the front, inside edge of the  
fuse holder, as shown in Figure 11A.  
4. Carefully pull the fuse holder from the Power Module. See Figure 11B.  
Power Output:  
Power Factor:  
Fuse:  
12VDC at 16.67 Amp max.  
>0.6 – 0.95, 10 to 100% load respectively  
6.3 Amp/250 Volts  
(A)  
(B )  
MTBF:  
Greater than 25,000 hours (MIL-HDBK-217F)  
Greater than 68,750 hours (Bellcore7 V5.0)  
Environment:  
Warranty:  
Operating temperature:  
Storage temperature:  
Humidity:  
0 to 50°C (32 to 122°F )  
-25 to 70°C (-13 to 158°F)  
Power ON/OFF  
Switch  
5 to 90%, non condensing  
Lifetime  
Fuse  
Place Small Flathead  
Screw Driver Here  
Fuse  
Holder  
Figures 11 A & B: Replacing Fuse  
4. Remove the fuse from the fuse holder.  
5. The replacement fuse MUST BE the same amperage and voltage rating.  
6. Insert the fuse into the holder.  
7. Slide the fuse holder fully into the Power Module.  
8. Connect the power cord to Power Module and to the external power.  
9. Push the power ON/OFF switch to the ON position.  
13  
Tech Support: 1-800-260-1312 – International: 00-1-952-941-7600 – (24 hours)  
[email protected] – Click the “Transition Now” link for a live Web chat.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IONPS-A, AC Power Module  
Troubleshooting  
Contact Us  
If the Power Module fails, isolate and correct the failure by determining the answers to  
the following questions and then taking the indicated action:  
Technical Support  
Technical support is available 24 hours a day.  
US and Canada:  
International:  
1-800-260-1312  
1.  
Is the Power LED on the IONPS-A, AC Power Module illuminated?  
NO  
00-1-952-941-7600  
Transition Now  
Chat live via the Web with Transition Networks Technical Support.  
Log onto www.transition.com and click the Transition Now link.  
Is the Power Module inserted properly into the chassis?  
Is the Power Module properly connected to the external power source?  
Does the external power source provide power?  
Contact Technical Support: US/Canada: 1-800-260-1312, International:  
00-1-952-941-7600.  
Web-Based Seminars  
Transition Networks provides seminars via live web-based training.  
Log onto www.transition.com and click the Learning Center link.  
YES  
Proceed to step 2.  
E-Mail  
Ask a question anytime by sending an e-mail to our technical support staff.  
2.  
Is the fuse on the IONPS-A, AC Power Module intact?  
NO  
CAUTION: See the “Replace the Fuse” section for the proper method  
for replacing the fuse to the Power Module.  
Address  
Transition Networks, 10900 Red Circle Drive, Minnetonka, MN 55343, U.S.A.  
telephone: 952-941-7600; toll free: 800-526-9267; fax: 952-941-2322  
Contact Technical Support: US/Canada: 1-800-260-1312, International:  
00-1-952-941-7600.  
YES  
Contact Technical Support: US/Canada: 1-800-260-1312, International:  
00-1-952-941-7600.  
Declaration of Conformity  
Name of Mfg:  
Model:  
Transition Networks  
10900 Red Circle Drive, Minnetoka, MN 55343 U.S.A.  
IONPS-A, AC Power Module 120/240 VAC  
Purpose: To declare that the IONPS-A, AC Power Module to which this declaration  
refers is in compliance with the following directive(s) and standard(s):  
EMC Directive 2004/108/EC; EN 55022:2006+A1:2007 Class A;  
EN55024:1998+A1:2001+A2:2003; EN6100-2-3; EN6100-3-3; CFR Title 47 Part 15  
Subpart B Class A. Low Voltage Directive: 2006/95/EC; EN60950-1:2006; CFR Title 21  
Section 1040.10 Class I.  
I, the undersigned, hereby declare that the model number(s) listed in this declaration of  
conformity is in compliance with the Directive(s) and Standard(s) herein.  
_January, 2010_____  
Stephen Anderson, Vice-President of Engineering  
Date  
15  
Tech Support: 1-800-260-1312 – International: 00-1-952-941-7600 – (24 hours)  
[email protected] – Click the “Transition Now” link for a live Web chat.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Compliance Information  
FCC Regulations  
This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment. This  
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in  
accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference, in which  
case the user will be required to correct the interference at the user's own expense.  
Canadian Regulations  
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out  
on the radio interference regulations of the Canadian Department of Communications.  
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables  
aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage  
radioélectrique édicté par le ministère des Communications du Canada.  
Trademark Notice  
All trademarks and registered trademarks are the property of their respective owners.  
Copyright Restrictions  
© 2009 – 2010 Transition Networks.  
All rights reserved. No part of this work may be reproduced or used in any form or by any means -  
graphic, electronic, or mechanical - without written permission from Transition Networks.  
Printed in the U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Technicolor Thomson DVD Player DSA100 User Manual
Tekram Technology CRT Television CaptureTV M205 User Manual
Texas Instruments Computer Hardware TMS320 DSP User Manual
Texas Instruments Laptop TM5000 Series User Manual
Toro Lawn Mower 96889SL User Manual
Toshiba Marine Battery Single phase 100V class 01 to 075kW User Manual
Tricity Bendix Dishwasher DH 102 User Manual
Tripp Lite Network Cables N002 007 BK User Manual
VBrick Systems Server 4410 0118 0009 User Manual
Wayne Plumbing Product ISP40 User Manual