Thermador Ventilation Hood HMWB36FS User Manual

Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL HMWB36FS SHOWN WITH 36-INCH GAS COOKTOP SGSX365FS  
132  
VENTILATION RANGE, RANGETOp AND VENTILATION MATRIX  
pROFESSIONAL SERIES  
= PErFECT FIT  
= VIABLE oPTIoN  
30-INCH  
36-INCH  
48-INCH  
30-INCH  
Pro GrAND  
Pro GrAND  
Pro GrAND  
Pro HArmoNY  
27-INCH DEPTH  
24-INCH DEPTH  
30" PH30Cs  
36" PH36Cs  
42" PH42Cs  
27-INCH DEPTH  
WALL HooDs  
48" PH48Cs  
54" PH54Cs  
30" HPWB30Fs  
36" HPWB36Fs  
48" HPWB48Fs*  
42" HNI42Ys  
48" HNI48Ys  
54" HNI54Ys  
30" VCI230Ds  
36" VCI236Ds  
48" VCI248Ds  
24-INCH DEPTH  
WALL HooDs  
IsLAND HooDs  
CusTom INsErTs  
The width of the hood should equal that of the cooktop or rangetop or exceed it by 3 inches on either side. Install these hoods only with Thermador blowers.  
*High heat tested to accommodate Pro Harmonyor Pro Rangetop 18,000 burners and grill.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
134  
VENTILATION RANGE, RANGETOp AND VENTILATION MATRIX  
pROFESSIONAL SERIES  
36-INCH  
48-INCH  
30-INCH  
36-INCH  
48-INCH  
PRO HARMONY  
PRO HARMONY  
RANGETOP  
RANGETOP  
RANGETOP  
24-INCH DEPTH  
24-INCH DEPTH  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
135  
VENTILATION COOKTOP AND VENTILATION MATRIX  
MASTERPIECE® SERIES  
= PErFECT FIT  
30-INCH  
36-INCH  
30-INCH  
36-INCH  
= VIABLE OPTION  
INDuCTION  
INDuCTION  
GAS COOKTOP  
GAS COOKTOP  
30" HMWB30FS  
36" HMWB36FS  
30" HMWN30FS  
36" HMWN36FS  
48" HMWN48FS  
36" HMCB36FS  
42" HMCB42FS  
36" HMCN36FS  
42" HMCN42FS  
WALL HOODS WITH BLOWEr  
WALL HOODS  
CHIMNEY HOODS WITH BLOWEr  
CHIMNEY HOODS  
36" HDDW36FS  
36" HGEW36FS  
DrAWEr HOOD  
GLASS CANOPY HOOD  
30" uCVM  
DOWNDrAFT  
36" uCVM  
21" VCI21CS  
29" VCI29CS  
CuSTOM INSErTS  
42" HGSI42TS  
ISLAND HOOD  
The width of the hood should equal that of the cooktop or rangetop or exceed it by 3 inches on either side. install these hoods only with Thermador blowers.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
136  
VENTILATION COOKTOP AND VENTILATION MATRIX  
MASTERPIECE® SERIES  
30-INCH  
30-INCH  
36-INCH  
ELECTrIC COOKTOP  
36-INCH  
ELECTrIC COOKTOP  
SENSOr ELECTrIC COOKTOP  
SENSOr ELECTrIC COOKTOP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
137  
VENTILATION BLOWER SELECTION AND DUCT GUIDE  
Type  
PROFESSIONAL SERIES  
Available  
Type  
Model No.  
Sizes (Widths)  
600  
1000  
600  
VTN630C  
VTN1030C  
VTR630D  
VTR1030D  
VTR1330E  
VTI610D  
4.8  
5.0  
4.3  
7.8  
9.2  
5.8  
7.6  
3.4  
10.2  
7.8  
9.2  
5.8  
7.6  
5.8  
5.2  
7.8  
9.5  
5.8  
7.6  
30", 36", 42",  
48", 54"  
1000  
1300  
600  
PH_CS  
WALL  
HOODS  
1000  
600  
VTI1010D  
Included  
Included  
VTR1030D  
VTR1330E  
VTI610D  
30"  
HPWB_FS  
HNI_YS  
36", 48"  
1200  
1000  
1300  
600  
ISLAND  
HOODS  
42", 48", 54"  
30", 36", 48"  
1000  
600  
VTI1010D  
VTI610D  
600  
VTR630D  
VTR1030D  
VTR1330E  
VTI610D  
1000  
1300  
600  
CUSTOM  
INSERTS  
VC12_DS  
1000  
VTI1010D  
MASTERPIECE® SERIES  
600  
600  
VTN600F  
VTR630D  
VTR1030D  
VTI610D  
4.6  
4.3  
7.8  
5.8  
7.6  
4.6  
8.8  
4.3  
7.8  
9.2  
5.8  
7.6  
3.4  
5.0  
6.7  
7.8  
9.2  
5.8  
7.6  
4.9  
4.9  
4.9  
3.0  
4.4  
6.7  
6.7  
10.2  
5.8  
7.6  
30"  
1000  
600  
1000  
600  
VTI1010D  
VTN600F  
VTN1000F  
VTR630D  
VTR1030D  
VTR1330E  
VTI610D  
HMWN_FS  
WALL  
HOODS  
1200  
600  
1000  
1300  
600  
36", 48"  
1000  
600  
VTI1010D  
Included  
VTN1080F  
VTR630D  
VTR1030D  
VTR1330E  
VTI610D  
HMWB_FS  
HMCN_FS  
30", 36"  
1000  
600  
1000  
1300  
600  
36", 42"  
CHIMNEY  
HOODS  
1000  
600  
VTI1010D  
Included  
Included  
Included  
Included  
Included  
VTN600CV2C  
VTR630D  
VTR1030D  
VTI610D  
HMCB_FS  
HGEW36FS  
HDDW36FS  
HGSI42TS  
VCI_CS  
36", 42"  
36"  
600  
36"  
600  
42"  
400  
ISLAND HOODS  
21", 29"  
400  
CUSTOM INSERTS  
600  
600  
DOWNDRAFT  
30", 36"  
1000  
600  
UCVM_FS  
1000  
VTI1010D  
*Purchase separately at most hardware stores, unless otherwise indicated with a Thermador model number.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
138  
VENTILATION BLOWER SELECTION AND DUCT GUIDE  
roof plate  
required  
Duct Size at Blower  
Transition  
with Backdraft  
Damper  
Duct Size  
at Discharge  
Discharge  
Direction  
36"only  
CV2T6  
CV2T6  
CV2T6  
CV2T6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
139  
VENTILATION BLOWER OPTIONS  
INTEGRAL (MOUNTED ON hOOD)  
vTn600Cv2C - 600 CFM  
vTn600F - 600 CFM  
vTn630C - 600 CFM  
83/4"  
81/4"  
25"  
vTn1080F - 1000 CFM  
vTn1000F - 1200 CFM  
vTn1030C - 1000 CFM  
81/4"  
25"  
REMOTE (MOUNTED TO ROOF OR EXTERNAL WALL)  
vTR630D - 600 CFM  
vTR1330E - 1300 CFM  
vTR1030D - 1000 CFM  
INLINE (MOUNTED BETWEEN KITChEN AND EXTERNAL WALL)  
vTi610D - 600 CFM  
vTi1010D - 1000 CFM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
140  
VENTILATION HOODS THAT FIT WITH YOUR KITCHEN  
When selecting a ventilation system, choose from one of our two sophisticated appliance collections. Select Professional Series for the ultimate  
in cooking and venting power or the Masterpiece® Series for its sleek styling and numerous convenience functions.  
WALL HOODS  
Wall hoods offer exceptional, quiet performance and distinctive design options.  
• Efficient, high quality, all stainless steel filters  
• Halogen lighting  
• Removable dishwasher safe grease collection tray  
• Recirculation option at 600 CFM  
• Deep enclosure area for excellent capture  
CHImNEY HOODS  
Our chimney style hoods impart a more traditional feel to the kitchen space.  
• Adjustable chimney heights suit a range of ceilings  
• Halogen lighting  
• All stainless steel or stainless steel with glass  
designs available  
• Dishwasher safe, stainless steel frame filters  
• Automatic “Time-to-Clean-Filter” reminder light  
ISLAND HOODS  
Thermador island hoods offer excellent overall efficiency in drawing away smoke, moisture and heat.  
• An option for when a wall surface is not available  
• Push button controls  
• Halogen or fluorescent lighting  
• All stainless steel or stainless steel with elegant  
glass canopy design  
CUSTOm INSERTS  
To create a seamless design with wall or island applications, use custom hood inserts.  
• Available options for all types of cooking surfaces  
• Wall or island applications  
• Halogen lighting  
• User-friendly ventilation controls or remote  
control options  
DOWNDRAFTS  
Downdraft ventilation offers space efficiency and a sleek look for non-professional cooktops.  
• Over 13-inch intake  
• Wall or island applications  
• Full face filter combines a filter with splatter shield  
in one easy-to-remove, dishwasher safe element  
• 600 CFM recirculation kit option with integral  
blower is available for difficult-to-duct situations  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
141  
MODEL HPWB48FS SHOWN WITH 48-INCH PRO HARMONY® RANGE PRD486GDHU  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AND 36-INCH WARMING DRAWER WDF30EP  
142  
VENTILATION  
WALL HOODS  
Thermador Wall Hoods put the finishing touch on your cooking  
system, with deep capture areas for the best overall efficiency  
in drawing away smoke, moisture and heat. These elegant  
hoods combine style with vigorous performance, generating  
ventilation power from 600 to 1,300 CFM. Available in a  
variety of heights, widths and depths, they accommodate your  
individual venting needs. All models include brilliant halogen  
lighting for enhanced visibility and convenient speed controls.  
For ultra-simple cleanup, the removable filters and grease  
collection trays fit easily in your dishwasher.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
143  
WALL HOODS FEATURES & BENEFITS  
BAFFLE FILTERS  
EXTERIOR CONTROLS  
Unique low-profile baffle  
filters maximize grease  
capture without affecting flow,  
and they’re dishwasher safe  
for easy clean-up.  
Easy-to-clean, easy-to-use  
push-button controls put  
accuracy at your fingertips.  
POWERFUL VENTILATION  
Breathe deeply with the air-freshening power of up to 1,300  
CFM. Our new HPWB Series Professional Hood now has blower  
included for ease of installation.  
HALOgEN LIgHTS  
Bright halogen lighting spotlights your best recipes.  
TImE-TO-CLEAN-FILTER LIgHT  
Easy clean-up: all Thermador ventilation filters are dishwasher  
safe, and many hoods feature a built-in Time-to-Clean-Filter  
reminder light. (Except HMWB30FS, HMWB36FS)  
DELAYED SHUTOFF  
For the greatest efficiency, our Professional ventilation  
models include delayed shut-off to tackle lingering odors.  
(Except HMWB30FS, HMWB36FS)  
KEEP-HOT SHELF  
Hold dishes at serving temperature on our optional Keep-Hot  
Shelf. (PH30CS, PH36CS, PH42CS, PH48CS and PH54CS only)  
PLANNINg INFORmATION  
mODEL OPTIONS  
ELECTRICAL SPECIFICATIONS  
When selecting a ventilation system, choose from  
one of our two sophisticated appliance collections.  
Select Professional Series for the ultimate in cooking  
and venting power or the Masterpiece® Series for its  
sleek styling and numerous convenience functions.  
Thermador Wall Hoods are available in various  
depths and heights to fit your kitchen plans and are  
meticulously crafted for both function and design.  
Be sure to reference the correct model information  
in this design guide.  
Be sure your Thermador Wall Hood is properly installed and grounded by a  
qualified technician. Installation, electrical connections and grounding must  
comply with all applicable local codes.  
Install a suitable conduit box (not furnished). An appropriately-sized, UL-listed  
conduit connector must be used to correctly attach the conduit to the junction  
box. Remote blowers require a five wire installation.  
mODEL  
REQUIRED CIRCUIT BREAKER  
120V AC, 60 Hz  
PH30CS, PH36CS, PH42CS,  
PH48CS, PH54CS  
20 Amp  
HPWB30FS, HPWB36FS, HPWB48FS  
15 or 20 Amp  
15 or 20 Amp  
HMWN30FS, HMWN36FS,  
HMWN48FS  
HMWB30FS, HMWB36FS  
15 or 20 Amp  
Download from Www.Somanuals.com. All Manuals Search And Download.  
144  
WALL HOODS PLANNINg INFORmATION  
Remote Blowers (VTR Series)  
INSTALLATION CONSIDERATIONS  
Depending on your preference and ducting situation, these blowers can be  
mounted on the roof or exterior wall of your home. An exterior installation  
may be more appealing to reduce noise in the kitchen.  
The information in this design guide provides key  
features, product dimensions, cutouts and installation  
specifications. Before installing a Thermador Wall  
Hood, be sure to verify the cutout dimensions and  
electrical connections. Also, always consult with  
the installation manual packed with the product for  
complete details before installing.  
Inline Blowers (VTI series)  
To minimize noise in the kitchen, these blowers are mounted along the  
duct line anywhere between the kitchen and the exterior wall. If you have  
easy access to your duct line (in an attic, for example), this may be an  
appealing option.  
Thermador Wall Hoods may be installed above a  
Thermador Cooktop or Range to create a convenient  
cooking center. Refer to the appropriate section for  
additional specifications.  
Integral Blowers (VTN series)  
These blowers are purchased separately and integrated into the hood or onto  
the downdraft unit at the time of installation. This option allows you to select  
your ideal hood with the exact power you require.  
HOOD WIDTH  
The hood width should be no less than the width of the  
cooking surface. Where space is not restricted, a wider  
hood can be used to increase your capture area.  
CHOOSINg THE RIgHT CFm  
The power of the cooktop or range, measured in BTU, is perhaps the most  
important factor in determining CFM needs for a hood. Professional gas  
cooktops generally should have 1 CFM for every 100 BTU.  
DISTANCE FROm COOKINg SURFACE  
You should also consider the cooking space and cooking style of your client.  
Proper mounting height is very important. If a hood  
is mounted too low, it may be difficult to cook and be  
unsafe. If a hood is mounted too high, performance  
may be compromised. For optimal performance, the  
distance from the cooking surface to the bottom of the  
hood should be a minimum of 30", unless otherwise  
noted. Please refer to the installation manual for each  
hood and cooktop/range model for proper hood  
mounting heights.  
• More demanding cooks usually require more exhaust capacity to handle  
moisture generated by boiling large pots of water or the grease and smoke  
resulting from grilling or frying. This cooking style could require a hood or  
downdraft system with airflow of 600 to 1,300 CFM.  
• For those who are used to preparing quick meals in a relatively small  
kitchen, a hood with 600 CFM may be adequate ventilation for the  
cooking space.  
• If the cooking surface is in a peninsula or island, a larger capacity hood can  
provide better capture when there are cross currents and when the hood  
needs to be mounted higher. Downdraft ventilation systems are also a good  
alternative.  
AVAILABLE CEILINg HEIgHT  
The standard ceiling height can vary from region to  
region and in homes built in different eras. Ceiling  
heights, even in the same room, can sometimes vary by  
as much as several inches. Kitchen ceiling heights can  
vary between 7'6" (or 90") to over 10' (or 120").  
• High heat cooking or aromatic foods may require additional CFM.  
Increasing capture area by 3" on each side is also a recommended way to  
address this issue.  
Before selecting a Thermador Hood, check the  
available installation space and any extra space that  
may remain after proper installation of a hood and  
cooktop or range. This extra space can be filled using  
Thermadors stainless steel duct cover accessories or  
integrated with kitchen cabinetry. The space can also  
be adjusted by raising or lowering your hood within the  
recommended range (typically 30" to 36" above the  
cooking surface).  
LENgTH AND SIzE OF DUCTWORK  
Do not use flexible duct; it creates back pressure/air turbulence and reduces  
performance.  
Straight runs and gradual turns are best. Use the shortest route with the  
fewest turns possible.  
Proper performance is dependent upon proper ducting. Use a qualified and  
trained installer. Local building codes may require the use of make-up air  
systems when using ducted ventilation systems greater than specified CFM of  
air movement. The specified CFM varies from locale to locale. Consult your  
HVAC professional for specific requirements in your area.  
CHOOSINg THE CORRECT BLOWER  
A variety of interior and exterior blower options  
(Remote, Inline or Integral) are available for  
If using a 10" duct, Thermador recommends not exceeding 150 feet of duct.  
Transitions, elbows and wall or roof caps are all factors that will add more  
static pressure, therefore increasing your equivalent duct run.  
Thermadors Professional and Masterpiece® Series  
Hoods. If the unit you have selected does not have  
a blower, one can be purchased separately. Blower  
selection will vary based on the volume of air that  
needs to be moved and the length and location of the  
duct run. For long duct runs with multiple turns and  
bends, consider using a more powerful blower. For the  
most efficient air flow exhaust, use a straight run or as  
few elbows as possible.  
WARRANTY  
Limited warranty parts and labor (1 year)  
See page 294 for additional warranty details.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
145  
VENTILATION 27-INCH DEPTH WALL HOOD (30"/36"/42"/48"/54")  
models: PH30CS, PH36CS, PH42CS, PH48CS, PH54CS  
PERFORmANCE  
- 3 fan speeds  
- Filters are highly efficient at capturing grease  
- Powerfully quiet ventilation systems  
- UL approved for damp environments  
- Extended capture area ensures removal of smoke and odor  
DESIgN  
- Brushed stainless steel finish  
- Double wall construction  
PROFESSIONAL  
PH30CS – 30-Inch  
PH36CS – 36-Inch  
PH42CS – 42-Inch  
PH48CS – 48-Inch  
PH54CS – 54-Inch  
- Welded, polished seams for a flawless design  
- Easy to operate control buttons  
- 27-inch depth hood is a perfect companion to the Pro Grand®  
professional range  
CONVENIENCE  
- Halogen lighting spotlights your best recipes  
- 2 Infrared Keep-Hot Lamps hold food warm until serving time  
- Dishwasher safe commercial-style baffle filter  
- Dimmer lighting  
- Grease collection trays are easily removed, dishwasher safe  
- After 40 hours of operation, the Clean Filter button illuminates  
- Auto start High Heat Sensor  
SPECIFICATIONS  
Available Hood Widths  
30", 36", 42", 48", 54"  
- Delayed shut off tackles lingering odors for up to 10 minutes  
- Blowers sold separately  
UL Approved for Damp  
Environments  
Yes  
- Hood includes filters, lights, backdraft damper and transition  
- Choose from Inline, Remote or Integrated Blowers  
Blower  
Sold Separately – See  
Blower Options Table  
Duct Size at Discharge  
Ducting Direction  
10" Round  
Vertical or Horizontal  
Dishwasher Safe Filters  
Commercial-Style  
Baffle  
Halogen Lighting  
30", 36", 42" – 2 Bulbs  
48", 54" – 3 Bulbs  
Infrared Keep-Hot Lights  
2
ACCESSORIES  
PHREmL – Remote Control Panel  
DC__US – 6-Inch High Duct Cover  
KHS__QS – Keep-Hot Shelf  
DCT__US – 12-Inch High Duct Cover  
(30"/36"/42"/48"/54") KHS30QS/KHS36QS/  
KHS42QS/KHS48QS/KHS54QS  
- Overall size: 14 1/2" W x 4 3/8" H  
- For use with PH_CS  
For use with PH__DS, HPWB__FS,  
HMWN__FS and HMWB__FS  
- For use with PH_CS  
- Stainless steel finish  
- Stainless steel finish  
- Cable-connected to blower  
and hood controls  
Width  
6-Inch High 12-Inch High  
- Convenient shelf allows dishes to keep hot  
at serving temperature. Includes stainless  
steel backguard and two shelves.  
30-Inch  
36-Inch  
42-Inch  
48-Inch  
DC30US  
DC36US  
N/A  
DCT30US  
DCT36US  
DCT42US  
DCT48US  
- Cable length: 30 ft.  
DC48US  
Download from Www.Somanuals.com. All Manuals Search And Download.  
146  
VENTILATION 27-INCH DEPTH WALL HOOD (30"/36"/42"/48"/54")  
models: PH30CS, PH36CS, PH42CS, PH48CS, PH54CS  
INSTALLATION OPTIONS  
Thermador Wall Hoods may be installed above a Thermador Cooktop  
or Range to create a convenient cooking center. Refer to the appropriate  
section for additional specifications.  
Hood installation height above a cooktop or range can vary. To obtain  
the necessary installation height above a Thermador Professional  
Cooktop or Range, consult the appliance's installation manual. Accessory  
6" and/or 12" duct covers are used to fill the space between the hood  
and ceiling.  
Both vertical and horizontal discharge is possible with either mounting  
method. The hood is shipped ready for vertical discharge.  
BLOWER OPTIONS  
REmOTE (mounted to roof or external wall)  
VTR630D 600 CFM VTR1030D 1000 CFM  
REmOTE  
VTR1330E 1300 CFM  
VTR630D – 600 CFM  
Use RFPLT600 in  
roof-mount applications  
VTR1030D – 1000 CFM  
VTR1330E – 1300 CFM  
Use RFPLT1000 in  
roof-mount applications  
INLINE  
VTI610D – 600 CFM  
VTI1010D – 1000 CFM  
INTEgRATED  
Use WC10 Wall Cap  
Use WC10 Wall Cap  
VTN630C – 600 CFM  
VTN1030C – 1000 CFM  
See page 145 for further details.  
INLINE (mounted between kitchen and external wall)  
VTI610D 600 CFM VTI1010D 1000 CFM  
INTEgRAL (mounted on hood)  
VTN630C 600 CFM  
VTN1030C 1000 CFM  
83/4"  
81/4"  
81/4"  
25"  
25"  
REmOTE BLOWER ACCESSORIES  
RFPLT600, RFPLT1000 – Roof plate Material  
For use with Remote Blowers VTR630D, VTR1030D and VTR1330E  
Combinations  
Overall Dimensions  
Roof plate  
RFPLT600  
RFPLT1000  
Remote Blower  
VTR630D  
model No.  
A
B
C
Duct Size  
6"  
RFPLT600  
7 1/2" 8 1/2" 9 1/4"  
12" 11 1/8"  
VTR1030D, VTR1330E  
RFPLT1000 9 3/8"  
10"  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
147  
VENTILATION 24-INCH DEPTH WALL HOOD WITH BLOWER (30"/36"/48")  
models: HPWB30FS, HPWB36FS, HPWB48FS  
PERFORmANCE  
- 3 fan speeds  
- Filters are highly efficient at capturing grease  
- Powerfully quiet ventilation systems  
- Extended capture area ensures removal of smoke and odor  
DESIgN  
- Brushed stainless steel finish  
PROFESSIONAL  
- Welded, polished seams for a flawless design  
- Stainless steel button controls  
HPWB30FS – 30-Inch  
HPWB36FS – 36-Inch  
HPWB48FS – 48-Inch  
CAPACITY  
- Integrated Blower included  
- Recirculation possible with kit RECIRC__FS (max 600 CFM)  
CONVENIENCE  
- Halogen lighting spotlights your best recipes  
- Dishwasher safe low-profile baffle filters  
- Grease collection trays are easily removed, dishwasher safe  
- Built-in Clean Filter Reminder light  
- Delayed shut off tackles lingering odors for up to 10 minutes  
- Hood includes filters, backdraft damper and transition  
- Accessories include: 6" Duct Covers or 12" Duct Covers  
SPECIFICATIONS  
Available Hood Widths 30", 36", 48"  
Blower  
30" – 600 CFM Blower Included  
36" – 1200 CFM Blower Included  
48" – 1200 CFM Blower Included  
Duct Size at Discharge 10" Round  
Ducting Direction Vertical  
Dishwasher Safe Filters Low-Profile Baffle  
Halogen Lighting  
30", 36" – 2 Bulbs  
48" – 3 Bulbs  
ACCESSORIES  
DC__US – 6-Inch High Duct Cover  
RECIRC__FS – Recirculation Kit  
CHFILT3036 – Replacement Charcoal Filters  
DCT__US – 12-Inch High Duct Cover  
(30"/36") RECIRC30FS/RECIRC36FS  
For use with Recirculation Kit  
For use with PH__DS, HPWB__FS,  
HMWN__FS and HMWB__FS  
- For use with HPWB30FS, HMWN__FS  
and HMWB__FS  
- Stainless steel finish  
Width  
6-Inch High 12-Inch High  
- Perfect for hard to duct installations  
- Use with 600 CFM blowers only  
30-Inch  
36-Inch  
48-Inch  
DC30US  
DC36US  
DC48US  
DCT30US  
DCT36US  
DCT48US  
4"  
12"  
30", 36"  
Download from Www.Somanuals.com. All Manuals Search And Download.  
148  
VENTILATION 24-INCH DEPTH WALL HOOD WITH BLOWER (30"/36"/48")  
models: HPWB30FS, HPWB36FS, HPWB48FS  
INSTALLATION OPTIONS  
Thermador Wall Hoods may be installed above a Thermador Cooktop or  
Range to create a convenient cooking center. Refer to the appropriate  
section for additional specifications.  
Hood installation height above a cooktop or range can vary. To obtain  
the necessary installation height above a Thermador Professional  
Cooktop or Range, consult the appliance's installation manual.  
Accessory 6" and/or 12" duct covers are used to fill the space between  
the hood and ceiling.  
This Thermador Wall Hood can be mounted on a wall or suspended from  
a cabinet. The cabinet must be structurally joined to the wall studs to  
support the weight of this hood.  
These hoods are designed to be used for vertical discharge. A ductless,  
recirculation installation is possible with kit RECIRC__FS.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
149  
VENTILATION WALL HOOD (30"/36"/48")  
models: HmWN30FS, HmWN36FS, HmWN48FS  
PERFORmANCE  
- 3 fan speeds plus 10 minute high-power operation mode  
- Filters are highly efficient at capturing grease  
- Powerfully quiet ventilation systems  
- Extended capture area ensures removal of smoke and odor  
DESIgN  
- Classic chiseled design matches Thermadors Masterpiece®  
mASTERPIECE  
Series family of kitchen appliances  
HMWN30FS – 30-Inch  
HMWN36FS – 36-Inch  
HMWN48FS – 48-Inch  
- Brushed stainless steel finish  
- Welded, polished seams for a flawless design  
- Premium electronic touch controls  
CAPACITY  
- Recirculation possible with kit RECIRC__FS (max 600 CFM)  
CONVENIENCE  
- Halogen lighting spotlights your best recipes  
- Dishwasher safe low-profile baffle filters  
- Grease collection trays are easily removed, dishwasher safe  
- Built-in Clean Filter Reminder light  
- Delayed shut off tackles lingering odors for up to 10 minutes  
- Blowers sold separately  
SPECIFICATIONS  
Available Hood Widths 30", 36", 48"  
- Choose from Inline, Remote or Integrated Blowers  
- Hood includes filters, backdraft damper and transition  
Blower  
Sold separately –  
See Blower Options table  
Duct Size at Discharge 10" Round  
Ducting Direction Vertical  
Dishwasher Safe Filters Low-Profile Baffle  
Halogen Lighting  
30", 36" – 2 Bulbs  
48" – 3 Bulbs  
ACCESSORIES  
DC__US – 6-Inch High Duct Cover  
RECIRC__FS – Recirculation Kit  
CHFILT3036 – Replacement Charcoal Filters  
DCT__US – 12-Inch High Duct Cover  
(30"/36") RECIRC30FS/RECIRC36FS  
For use with Recirculation Kit  
For use with PH__DS, HPWB__FS,  
HMWN__FS and HMWB__FS  
- For use with HPWB30FS, HMWN__FS  
and HMWB__FS  
- Stainless steel finish  
Width  
6-Inch High 12-Inch High  
- Perfect for hard to duct installations  
- Use with 600 CFM blowers only  
30-Inch  
36-Inch  
48-Inch  
DC30US  
DC36US  
DC48US  
DCT30US  
DCT36US  
DCT48US  
4"  
12"  
30", 36"  
Download from Www.Somanuals.com. All Manuals Search And Download.  
150  
VENTILATION WALL HOOD (30"/36"/48")  
models: HmWN30FS, HmWN36FS, HmWN48FS  
INSTALLATION OPTIONS  
Thermador Wall Hoods may be installed above a Thermador Cooktop or  
Range to create a convenient cooking center. Refer to the appropriate section  
for additional specifications.  
Hood installation height above a cooktop or range can vary. To obtain the  
necessary installation height above a Thermador Professional Cooktop or  
Range, consult the appliance's installation manual.  
Accessory 6" and/or 12" duct covers are used to fill the space between the  
hood and ceiling.  
Thermador Wall Hoods can be mounted on a wall or suspended from a  
cabinet. The cabinet must be structurally joined to the wall studs to support  
the weight of this hood.  
These hoods are designed to be used for vertical discharge. A ductless,  
recirculation installation is possible with kit RECIRC__FS.  
These hoods are not recommended to be used over indoor grills.  
BLOWER OPTIONS  
REmOTE (mounted to roof or external wall)  
VTR630D 600 CFM VTR1030D 1000 CFM  
REmOTE  
VTR630D – 600 CFM  
Use RFPLT600 in  
roof-mount applications  
VTR1330E 1300 CFM  
VTR1030D – 1000 CFM Use RFPLT1000 in  
roof-mount applications  
VTR1330E – 1300 CFM Use RFPLT1000 in  
roof-mount applications  
(Not for use with 30" hood)  
INLINE  
VTI610D – 600 CFM  
VTI1010D – 1000 CFM  
INTEgRATED  
VTN600F – 600 CFM  
VTN1000F – 1200 CFM Not for use with 30" hood  
See page 145 for further details.  
INLINE (mounted between kitchen and external wall)  
INTEgRAL (mounted on hood)  
VTI610D 600 CFM  
VTI1010D 1000 CFM  
VTN600F 600 CFM  
VTN1000F 1200 CFM  
REmOTE BLOWER ACCESSORIES  
RFPLT600, RFPLT1000 – Roof plate Material  
For use with Remote Blowers VTR630D, VTR1030D and VTR1330E  
Combinations  
Overall Dimensions  
Roof plate  
RFPLT600  
RFPLT1000  
Remote Blower  
VTR630D  
model No.  
A
B
C
Duct Size  
6"  
RFPLT600  
7 1/2" 8 1/2" 9 1/4"  
12" 11 1/8"  
VTR1030D, VTR1330E  
RFPLT1000 9 3/8"  
10"  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
151  
VENTILATION WALL HOOD WITH BLOWER (30"/36")  
models: HmWB30FS, HmWB36FS  
PERFORmANCE  
- 3 fan speeds plus 10 minute high-power operation mode  
- Filter systems are highly efficient at capturing grease  
- Powerfully quiet ventilation systems  
- Extended capture area ensures removal of smoke and odor  
DESIgN  
- Classic chiseled design matches Thermadors Masterpiece® Series  
mASTERPIECE  
family of kitchen appliances  
HMWB30FS – 30-Inch  
HMWB36FS – 36-Inch  
- Brushed stainless steel finish  
- Welded, polished seams for a flawless design  
- Easy to operate control buttons  
CAPACITY  
- 600 CFM Integrated Blower included  
- Recirculation possible with kit RECIRC__FS (max 600 CFM)  
CONVENIENCE  
- Halogen lighting spotlights your best recipes  
- Dishwasher safe low-profile baffle filters  
- Grease collection trays are easily removed, dishwasher safe  
- Hood includes filters, backdraft damper and transition  
SPECIFICATIONS  
Available Hood Widths 30", 36"  
Blower  
600 CFM Blower Included  
Duct Size at Discharge 10" Round  
Ducting Direction  
Vertical  
Dishwasher Safe Filters Low-Profile Baffle  
Halogen Lighting  
2
ACCESSORIES  
DC__US – 6-Inch High Duct Cover  
RECIRC__FS – Recirculation Kit  
CHFILT3036 – Replacement Charcoal Filters  
DCT__US – 12-Inch High Duct Cover  
(30"/36") RECIRC30FS/RECIRC36FS  
For use with Recirculation Kit  
For use with PH__DS, HPWB__FS,  
HMWN__FS and HMWB__FS  
- For use with HPWB__FS, HMWN__FS  
and HMWB__FS  
- Stainless steel finish  
Width  
6-Inch High 12-Inch High  
- Perfect for hard to duct installations  
- Use with 600 CFM blowers only  
30-Inch  
36-Inch  
DC30US  
DC36US  
DCT30US  
DCT36US  
4"  
12"  
30", 36"  
Download from Www.Somanuals.com. All Manuals Search And Download.  
152  
VENTILATION WALL HOOD WITH BLOWER (30"/36")  
Models: HMWB30FS, HMWB36FS  
INSTALLATION OPTIONS  
Thermador Wall Hoods may be installed above a Thermador Cooktop or  
Range to create a convenient cooking center. Refer to the appropriate section  
for additional specifications.  
Hood installation height above a cooktop or range can vary. To obtain the  
necessary installation height above a Thermador Professional Cooktop or  
Range, consult the appliance's installation manual.  
Accessory 6" and/or 12" duct covers are used to fill the space between the  
hood and ceiling.  
Thermador Wall Hoods can be mounted on a wall or suspended from a  
cabinet. The cabinet must be structurally joined to the wall studs to support  
the weight of this hood.  
These hoods are designed to be used for vertical discharge. A ductless,  
recirculation installation is possible with kit RECIRC__FS.  
These hoods are not recommended to be used over indoor grills.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
153  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL HMCB42FS SHOWN WITH 36-INCH GAS COOKTOP SGSX365FS  
154  
VENTILATION  
CHIMNEY WALL HOODS  
Our Masterpiece® Series Chimney Style Hoods impart a more  
open kitchen environment and create a dramatic gathering point.  
Each model is adjustable to suit a range of ceiling heights and  
includes conveniences such as dishwasher safe, anodized filters  
and electronic 4-speed controls. Halogen lighting brilliantly  
illuminates your cooking space for excellent visibility.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
155  
CHIMNEY WALL HOODS FEATURES & BENEFITS  
MESH FILTERS  
Aluminum mesh filters with stainless  
steel frame maximize grease capture  
without affecting flow and feature a  
quick release latch for easy clean-up.  
ELECTRONIC TOUCH CONTROL  
The sleek electronic touch control panel is easy to use and easy to clean.  
TIME-TO-CLEAN-FILTER LIgHT  
HALOgEN LIgHTS  
Easy clean-up: All Thermador ventilation filters are dishwasher safe,  
and many hoods feature a built-in Time-to-Clean-Filter reminder light.  
(Except HMCB36FS, HMCB42FS)  
Bright halogen lighting spotlights your best recipes.  
DELAYED SHUTOFF  
For the greatest efficiency, our Masterpiece® ventilation models  
include delayed shutoff to tackle lingering odors. (Except HMCB36FS,  
HMCB42FS)  
PLANNINg INFORMATION  
MODEL OPTIONS  
ELECTRICAL SPECIFICATIONS  
Thermador Masterpiece Series Chimney Wall Hoods  
feature sleek styling and numerous convenience  
functions. Chimney Wall Hoods are available in  
36-inch and 42-inch widths and are adjustable to  
suit a range of ceiling heights. All stainless steel or  
stainless steel with glass designs are available. Be  
sure to reference the correct model information in  
this design guide.  
Be sure your Thermador Chimney Wall Hood is properly installed and  
grounded by a qualified technician. Installation, electrical connections and  
grounding must comply with all applicable local codes.  
If possible, site the earthed socket directly behind the chimney paneling.  
The grounded socket should be connected via its own circuit. If the  
grounded socket is no longer accessible following installation of the hood,  
ensure that there is a permanently installed disconnector.  
MODEL  
REQUIRED CIRCUIT BREAKER  
120 V AC, 60 Hz  
HMCN36FS, HMCN42FS,  
HMCB36FS, HMCB42FS,  
HGEW36FS, HDDW36FS  
15 AMP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
156  
CHIMNEY WALL HOODS PLANNINg INFORMATION  
Remote Blowers (VTR Series)  
INSTALLATION CONSIDERATIONS  
Depending on your preference and ducting situation, these blowers can be  
mounted on the roof or exterior wall of your home. An exterior installation  
may be more appealing to reduce noise in the kitchen.  
The information in this design guide provides key  
features, product dimensions, cutouts and installation  
specifications. Before installing a Thermador Chimney  
Wall Hood, be sure to verify the cutout dimensions  
and electrical connections. Also, always consult with  
the installation manual packed with the product for  
complete details before installing.  
Inline Blowers (VTI series)  
To minimize noise in the kitchen, these blowers are mounted along the  
duct line anywhere between the kitchen and the exterior wall. If you have  
easy access to your duct line (in an attic, for example), this may be an  
appealing option.  
Thermador Chimney Wall Hoods may be installed  
above a Thermador non-professional gas, electric,  
or induction cooktop to create a convenient cooking  
center. Refer to the appropriate section for additional  
specifications.  
Integral Blowers (VTN series)  
These blowers are purchased separately and integrated into the hood or onto  
the downdraft unit at the time of installation. This option allows you to select  
your ideal hood with the exact power you require.  
HOOD WIDTH  
CHOOSINg THE RIgHT CFM  
The hood width should be no less than the width of the  
cooking surface. Where space is not restricted, a wider  
hood can be used to increase your capture area.  
The power of the cooktop or range, measured in BTU, is perhaps the most  
important factor in determining CFM needs for a hood. Professional gas  
cooktops generally should have 1 CFM for every 100 BTU. For Masterpiece®  
Electric and Induction Cooktops, and Gas Cooktops under 60,000 BTU,  
choose a blower with a minimum of 100 CFM per 12" of cooktop width.  
DISTANCE FROM COOKINg SURFACE  
Proper mounting height is very important. If a hood  
is mounted too low, it may be difficult to cook and be  
unsafe. If a hood is mounted too high, performance  
may be compromised. For optimal performance, the  
distance from the cooking surface to the bottom of the  
hood should be a minimum of 30", unless otherwise  
noted. Please refer to the installation manual for each  
hood and cooktop/range model for proper hood  
mounting heights.  
You should also consider the cooking space and cooking style of your client.  
• More demanding cooks usually require more exhaust capacity to handle  
moisture generated by boiling large pots of water or the grease and smoke  
resulting from grilling or frying. This cooking style could require a hood or  
downdraft system with airflow of 600 to 1300 CFM.  
• For those who are used to preparing quick meals in a relatively small  
kitchen, a hood with 600 CFM may be adequate ventilation for the  
cooking space.  
AVAILABLE CEILINg HEIgHT  
• If the cooking surface is in a peninsula or island, a larger capacity hood can  
provide better capture when there are cross currents and when the hood  
needs to be mounted higher. Downdraft ventilation systems are also a good  
alternative.  
The standard ceiling height can vary from region to  
region and in homes built in different eras. Ceiling  
heights, even in the same room, can sometimes vary by  
as much as several inches. Kitchen ceiling heights can  
vary between 7'6" (or 90") to over 10' (or 120").  
• High heat cooking or aromatic foods may require additional CFM.  
Increasing capture area by 3" on each side is also a recommended way to  
address this issue.  
Before selecting a Thermador Hood, check the  
available installation space and any extra space that  
may remain after proper installation of a hood and  
cooktop or range. This extra space can be filled using  
Thermadors stainless steel duct cover accessories. The  
space can also be adjusted by raising or lowering your  
hood within the recommended range (typically 30" to  
36" above the cooking surface).  
LENgTH AND SIzE OF DUCTWORK  
Do not use flexible duct; it creates back pressure/air turbulence and reduces  
performance.  
Straight runs and gradual turns are best. Use the shortest route with the  
fewest turns possible.  
Proper performance is dependent upon proper ducting. Use a qualified and  
trained installer. Local building codes may require the use of makeup air  
systems when using ducted ventilation systems greater than specified CFM of  
air movement. The specified CFM varies from locale to locale. Consult your  
HVAC professional for specific requirements in your area.  
CHOOSINg THE CORRECT BLOWER  
A variety of interior and exterior blower options  
(Remote, Inline or Integral) are available for  
Thermadors Masterpiece® Series Hoods. If the unit you  
have selected does not have a blower included, one  
can be purchased separately. Blower selection will vary  
based on the volume of air that needs to be moved  
and the length and location of the duct run.  
For long duct runs with multiple turns and bends,  
consider using a more powerful blower. For the most  
efficient air flow exhaust, use a straight run or as few  
elbows as possible.  
If using a 10" duct, Thermador recommends not exceeding 150 feet of duct.  
Transitions, elbows and wall or roof caps are all factors that will add more  
static pressure, therefore increasing your equivalent duct run.  
WARRANTY  
Limited warranty parts and labor (1 year)  
See page 294 for additional warranty details.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
157  
VENTILATION CHIMNEY WALL HOOD (36"/42")  
Models: HMCN36FS, HMCN42FS  
PERFORMANCE  
- 3 fan speeds plus 10 minute high-power operation mode  
- Filters are highly efficient at capturing grease  
- Powerfully quiet ventilation systems  
DESIgN  
- Classic chiseled design matches Thermadors Masterpiece®  
Series family of kitchen appliances  
- Brushed stainless steel finish  
- Welded, polished seams for a flawless design  
- Premium electronic touch controls  
CONVENIENCE  
- Halogen lighting spotlights your best recipes  
- Dishwasher safe stainless-frame mesh filters  
- Dimmer lighting – for those hours after a late meal  
- Built-in Clean Filter Reminder light  
MASTERPIECE  
- Telescopic chimney – adjustable at installation  
- Delayed shutoff tackles lingering odors for up to 10 minutes  
- Blowers sold separately  
HMCN36FS – 36-Inch  
HMCN42FS – 42-Inch  
- Choose from Inline, Remote or Integrated Blowers  
SPECIFICATIONS  
Available Hood Widths 36", 42"  
Blower  
Sold Separately—  
See Blower Options Table  
Duct Size at Discharge 8" Round  
Ducting Direction  
Ceiling Heights  
Vertical  
8 ft. to 9 ft.  
Dishwasher Safe Filters 3 Mesh with Stainless Frame  
Halogen Lighting  
3
ACCESSORIES  
CHIMXHMC – Chimney Extension  
- For use with HMCN_FS, HMCB_FS  
- Stainless steel chimney hood extension  
for up to 12-foot ceiling applications  
- Extension replaces upper section of  
standard chimney extension  
Download from Www.Somanuals.com. All Manuals Search And Download.  
158  
VENTILATION CHIMNEY WALL HOOD (36"/42")  
Models: HMCN36FS, HMCN42FS  
INSTALLATION OPTIONS  
Thermador Chimney Wall Hoods may be installed above a  
Thermador non-professional gas, electric, or induction cooktop  
to create a convenient cooking center. Refer to the appropriate  
section for additional specifications.  
Hood installation height above a cooktop can vary. To obtain the  
necessary installation height above a Thermador non-professional  
gas, electric, or induction cooktop, consult the appliances  
installation manual.  
Thermador Chimney Wall Hoods must be mounted on a wall.  
These hoods are designed to be used for vertical discharge.  
A blower must be purchased separately.  
BLOWER OPTIONS  
REMOTE  
VTR630D – 600 CFM  
Use RFPLT600 in  
roof-mount applications  
VTR1030D – 1000 CFM  
VTR1330E – 1300 CFM  
INLINE  
Use RFPLT1000 in  
roof-mount applications  
VTI610D – 600 CFM  
VTI1010D – 1000 CFM  
INTEgRATED  
VTN1080F – 1000 CFM  
See page 145 for further details.  
REMOTE (Mounted to roof or external wall)  
VTR630D 600 CFM  
INLINE (Mounted between kitchen and external wall)  
VTR1330E 1300 CFM  
VTI610D 600 CFM  
VTI1010D 1000 CFM  
VTR1030D 1000 CFM  
INTEgRAL (Mounted on hood)  
REMOTE BLOWER ACCESSORIES  
RFPLT600, RFPLT1000 – Roofplate Material  
VTN1080F 1000 CFM  
For use with Remote Blowers VTR630D, VTR1030D and VTR1330E  
Combinations  
Roofplate  
RFPLT600  
RFPLT1000  
Remote Blower  
VTR630D  
VTR1030D, VTR1330E  
Overall Dimensions  
Model No.  
RFPLT600  
A
B
C
Duct Size  
6"  
7 1/2" 8 1/2" 9 1/4"  
12" 11 1/8"  
RFPLT1000 9 3/8"  
10"  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
159  
VENTILATION CHIMNEY WALL HOOD WITH BLOWER (36"/42")  
Models: HMCB36FS, HMCB42FS  
PERFORMANCE  
- 3 fan speeds plus 10 minute high-power operation mode  
- Filters are highly efficient at capturing grease  
- Powerfully quiet ventilation systems  
DESIgN  
- Classic chiseled design matches Thermadors Masterpiece®  
Series family of kitchen appliances  
- Brushed stainless steel finish  
- Welded, polished seams for a flawless design  
- Easy to operate control buttons  
CAPACITY  
- 600 CFM Integrated Blower included  
CONVENIENCE  
- Halogen lighting spotlights your best recipes  
- Dishwasher safe stainless-frame mesh filters  
- Telescopic chimney – adjustable at installation  
- Hood includes filters, lights, backdraft damper and transition  
MASTERPIECE  
HMCB36FS – 36-Inch  
HMCB42FS – 42-Inch  
SPECIFICATIONS  
Available Hood Widths 36", 42"  
Blower  
600 CFM Blower Included  
Duct Size at Discharge 6" Round  
Ducting Direction  
Ceiling Heights  
Vertical  
8 ft. to 9 ft.  
Dishwasher Safe Filters 3 Mesh  
Halogen Lighting  
3
ACCESSORIES  
CHIMXHMC – Chimney Extension  
- For use with HMCB__FS, HMCN__FS  
- Stainless steel chimney hood extension  
for up to 12-foot ceiling applications  
- Extension replaces upper section of  
standard chimney extension  
Download from Www.Somanuals.com. All Manuals Search And Download.  
160  
VENTILATION CHIMNEY WALL HOOD WITH BLOWER (36"/42")  
Models: HMCB36FS, HMCB42FS  
INSTALLATION OPTIONS  
Thermador Chimney Wall Hoods may be installed above a  
Thermador non-professional gas, electric, or induction cooktop  
to create a convenient cooking center. Refer to the appropriate  
section for additional specifications.  
Hood installation height above a cooktop can vary. To obtain the  
necessary installation height above a Thermador non-professional  
gas, electric, or induction cooktop, consult the appliance's  
installation manual.  
Thermador Chimney Wall Hoods must be mounted on a wall.  
These hoods are designed to be used for vertical discharge.  
A 600 CFM integrated blower is included.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
161  
VENTILATION PIVOT-LIFT gLASS CANOPY HOOD (36")  
Model: HgEW36FS  
PERFORMANCE  
- Lower the unique glass canopy for greater capture area  
- 3 fan speeds plus 10 minute high-power operation mode  
- Filters are highly efficient at capturing grease  
- Powerfully quiet ventilation systems  
DESIgN  
- Brushed stainless steel finish  
- Welded, polished seams for a flawless design  
- Premium electronic touch controls  
- Elegantly curved glass canopy  
CAPACITY  
- 600 CFM Integrated Blower included  
CONVENIENCE  
MASTERPIECE  
- Halogen lighting spotlights your best recipes  
- Dishwasher safe stainless-frame mesh filters  
- Dimmer lighting – for those hours after a late meal  
- Unique canopy pivots up – offering increased head room  
- Built-in Clean Filter Reminder light  
HGEW36FS – 36-Inch  
- Telescopic chimney – adjustable at installation  
- Delayed shutoff tackles lingering odors for up to 10 minutes  
- Hood includes filters, lights, backdraft damper and transition  
SPECIFICATIONS  
Available Hood Widths 36"  
Blower  
600 CFM Blower Included  
Duct Size at Discharge 6" Round  
Ducting Direction  
Ceiling Heights  
Vertical  
8 ft. to 9 3/4 ft.  
Dishwasher Safe Filters 1 Mesh  
Halogen Lighting  
2
ACCESSORIES  
CHIMXHgE – Chimney Extension  
- For use with HGEW__FS  
- Stainless steel chimney hood extension  
for up to 12-foot ceiling applications  
- Extension replaces upper section of  
standard chimney extension  
Download from Www.Somanuals.com. All Manuals Search And Download.  
162  
VENTILATION PIVOT-LIFT gLASS CANOPY HOOD (36")  
Model: HgEW36FS  
INSTALLATION OPTIONS  
Thermador Chimney Wall Hoods may be installed above a  
Thermador non-professional gas, electric, or induction cooktop  
to create a convenient cooking center. Refer to the appropriate  
section for additional specifications.  
Hood installation height above a cooktop can vary. To obtain the  
necessary installation height above a Thermador non-professional  
gas, electric, or induction cooktop, consult the appliance's  
installation manual.  
Thermador Chimney Wall Hoods must be mounted on a wall.  
This hood is designed to be used for vertical discharge.  
A 600 CFM integrated blower is included.  
Installation Note: This product ships with two transport  
brackets to hold the moveable canopy in place during  
shipping and installation. After installation, be sure to  
remove the brackets to operate the pivot-lift glass canopy.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
163  
VENTILATION CHIMNEY WALL DRAWER HOOD (36")  
Model: HDDW36FS  
PERFORMANCE  
- 3 fan speeds plus 10 minute high-power operation mode  
- 45% increase in capture area when hood is extended  
- Filters are highly efficient at capturing grease  
- Powerfully quiet ventilation systems  
- Sound insulation mats make this hood barely audible  
DESIgN  
- Classic chiseled design matches Thermadors Masterpiece®  
Series family of kitchen appliances  
- Brushed stainless steel finish  
- Welded, polished seams for a flawless design  
- Premium electronic touch controls  
MASTERPIECE  
HDDW36FS – 36-Inch  
CAPACITY  
- 600 CFM Integrated Blower included  
CONVENIENCE  
- Halogen lighting spotlights your best recipes  
- Dishwasher safe stainless-frame mesh filters  
- Dimmer lighting – for those hours after a late meal  
- Unique sliding stainless steel canopy can be pushed back  
against the wall to increase the capture area  
- Built-in Clean Filter Reminder light  
- Telescopic chimney – adjustable at installation  
- Delayed shutoff tackles lingering odors for up to 10 minutes  
- Hood includes filters, lights, backdraft damper and transition  
SPECIFICATIONS  
Available Hood Widths 36"  
Blower  
600 CFM Blower Included  
Duct Size at Discharge 6" Round  
Ducting Direction  
Ceiling Heights  
Vertical  
7 3/4 ft. to 9 1/2 ft.  
Dishwasher Safe Filters 4 Mesh  
Halogen Lighting  
4
ACCESSORIES  
CHIMXHDD – Chimney Extension  
- For use with HDDW__FS  
- Stainless steel chimney hood extension  
for up to 12-foot ceiling applications  
- Extension replaces upper section of  
standard chimney extension  
Download from Www.Somanuals.com. All Manuals Search And Download.  
164  
VENTILATION CHIMNEY WALL DRAWER HOOD (36")  
Model: HDDW36FS  
INSTALLATION OPTIONS  
Thermador Chimney Wall Hoods may be installed above a  
Thermador non-professional gas, electric, or induction cooktop  
to create a convenient cooking center. Refer to the appropriate  
section for additional specifications.  
Hood installation height above a cooktop can vary. To obtain the  
necessary installation height above a Thermador non-professional  
gas, electric, or induction cooktop, consult the appliance's  
installation manual.  
Thermador Chimney Wall Hoods must be mounted on a wall.  
This hood is designed to be used for vertical discharge.  
A 600 CFM integrated blower is included.  
Installation Note: This product ships with two transport  
brackets to hold the moveable canopy in place during  
shipping and installation. After installation, be sure to  
remove the brackets to operate the sliding drawer canopy.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
165  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL HGSI42TS SHOWN WITH 36-INcH INDUcTION cOOKTOP cIS365GB AND DISHWASHER DWHD410GFM  
166  
VENTILATION  
ISLAND HOODS  
Thermador Island Hoods put the finishing touches on your  
cooking system, with excellent overall efficiency in drawing away  
smoke, moisture and heat. The adjustable chimney height is  
perfect over island cooktop or range installations. Dishwasher  
safe aluminum mesh filters make cleanup easy.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
167  
ISLAND HOODS FEATURES & BENEFITS  
HALOgEN LIgHTS  
Bright halogen lighting  
spotlights your best recipes.  
(HGSI42TS only)  
POWERFULLY QUIETOPERATION  
Steam, smoke and odors are no problem for Thermador's ducted  
ventilation systems.  
TIME-TO-CLEAN-FILTER LIgHT  
Easy clean-up: All Thermador ventilation filters are dishwasher  
safe, and many hoods feature a built-in Time-to-Clean-Filter  
reminder light. (HNI42YS, HNI48YS, HNI54YS only)  
EXTERIOR CONTROLS  
DISHWASHER SAFE FILTERS  
Easy-to-clean, easy-to-use push-button controls put accuracy  
at your fingertips.  
Dishwasher-safe anodized aluminum mesh filters for easy-clean  
maintenance.  
DELAYED SHUTOFF  
For the greatest efficiency, our Professional ventilation models  
include delayed shutoff to tackle lingering odors. (HNI42YS,  
HNI48YS, HNI54YS only)  
PLANNING INFORMATION  
MODEL OPTIONS  
ELECTRICAL SPECIFICATIONS  
Thermador Professional Series Island Hoods are  
available in 42-inch, 48-inch and 54-inch widths and  
feature a stainless steel design. A Masterpiece®  
Series Island Hood is available in a 42-inch width  
and features a stainless steel design with an elegant  
glass canopy. All of our island hoods are adjustable  
to suit a range of ceiling heights.  
Be sure your Thermador Wall Hood is properly installed and grounded by a  
qualified technician. Installation, electrical connections and grounding must  
comply with all applicable local codes.  
MODEL  
REQUIRED CIRCUIT BREAKER  
120 V AC, 60 Hz  
HNI42YS, HNI48YS,  
HNI54YS, HGSI42TS  
15 Amp  
Download from Www.Somanuals.com. All Manuals Search And Download.  
168  
ISLAND HOODS PLANNINg INFORMATION  
Remote Blowers (VTR Series)  
INSTALLATION CONSIDERATIONS  
Depending on your preference and ducting situation, these blowers can be  
mounted on the roof or exterior wall of your home. An exterior installation may  
be more appealing to reduce noise in the kitchen.  
The information in this design guide provides  
key features, product dimensions and installation  
specifications. Before installing a Thermador  
Island Hood, be sure to verify the dimensions and  
electrical connections. Also, always consult with  
the installation manual packed with the product for  
complete details before installing.  
Inline Blowers (VTI Series)  
To minimize noise in the kitchen, these blowers are mounted along the  
duct line anywhere between the kitchen and the exterior wall. If you have  
easy access to your duct line (in an attic, for example), this may be an appealing  
option.  
Thermador Island Hoods may be installed above a  
Thermador Cooktop or Range to create a convenient  
cooking center. Refer to the appropriate section for  
additional specifications.  
Integral Blowers (VTN Series)  
These blowers are purchased separately and integrated into the hood or onto  
the downdraft unit at the time of installation. This option allows you to select  
your ideal hood with the exact power you require.  
HOOD WIDTH  
The hood width should be no less than the width of  
the cooking surface. Where space is not restricted,  
a wider hood can be used to increase your capture  
area. Island installations require a greater capture  
area; therefore the hoods used should overlap your  
cooking surface by a minimum of 3" to 6" on  
either side.  
CHOOSINg THE RIgHT CFM  
The power of the cooktop or range, measured in BTU, is perhaps the most  
important factor in determining CFM needs for a hood. Professional Gas  
Cooktops generally should have 1 CFM for every 100 BTU. For Masterpiece®  
Electric and Induction Cooktops, and Gas Cooktops under 60,000 BTU, choose  
a blower with a minimum of 100 CFM per 12" of cooktop width.  
You should also consider the cooking space and cooking style of your client.  
DISTANCE FROM COOKINg SURFACE  
• More demanding cooks usually require more exhaust capacity to handle  
moisture generated by boiling large pots of water or the grease and smoke  
resulting from grilling or frying. This cooking style could require a hood or  
downdraft system with airflow of 600 to 1,300 CFM.  
Proper mounting height is very important. If a  
hood is mounted too low, it may be difficult to  
cook and be unsafe. If a hood is mounted too high,  
performance may be compromised. For optimal  
performance, the distance from the cooking surface  
to the bottom of the hood should be a minimum  
of 30", unless otherwise noted. Please refer to the  
installation manual for each hood and cooktop/  
range model for proper hood mounting heights.  
• For those who are used to preparing quick meals in a relatively small kitchen, a  
hood with 400 to 600 CFM may be adequate ventilation for the cooking space.  
• If the cooking surface is in a peninsula or island, a larger capacity hood can  
provide better capture when there are cross currents and when the hood  
needs to be mounted higher. Downdraft ventilation systems are also a  
good alternative.  
AVAILABLE CEILINg HEIgHT  
• High heat cooking or aromatic foods may require additional CFM. Increasing  
capture area by 3" on each side is also a recommended way to address  
this issue.  
The standard ceiling height can vary from region to  
region and in homes built in different eras. Ceiling  
heights, even in the same room, can sometimes vary  
by as much as several inches. Kitchen ceiling heights  
can vary between 7'6" (or 90") to over 10' (or 120").  
LENgTH AND SIzE OF DUCTWORK  
Do not use flexible duct; it creates back pressure/air turbulence and reduces  
performance.  
Before selecting a Thermador Hood, check the  
available installation space and any extra space  
that may remain after proper installation of a  
hood and cooktop or range. This extra space can  
be filled using Thermadors stainless steel duct  
cover accessories. The space can also be adjusted  
by raising or lowering your hood within the  
recommended range (typically 30" to 36" above  
the cooking surface).  
Straight runs and gradual turns are best. Use the shortest route with the fewest  
turns possible.  
Proper performance is dependent upon proper ducting. Use a qualified and  
trained installer. Local building codes may require the use of make-up air  
systems when using ducted ventilation systems greater than specified CFM of air  
movement. The specified CFM varies from locale to locale. Consult your HVAC  
professional for specific requirements in your area.  
CHOOSINg THE CORRECT BLOWER  
If using a 10" duct, Thermador recommends not exceeding 150 feet of duct.  
Transitions, elbows and wall or roof caps are all factors that will add more static  
pressure, therefore increasing your equivalent duct run.  
A variety of interior and exterior blower options  
(Remote, Inline or Integral) are available for  
Thermadors Professional Series Island Hoods. If the  
unit you have selected does not have a blower, one  
can be purchased separately. Blower selection will  
vary based on the volume of air that needs to be  
moved and the length and location of the duct run.  
For long duct runs with multiple turns and bends,  
consider using a more powerful blower. For the most  
efficient air flow exhaust, use a straight run or as few  
elbows as possible.  
WARRANTY  
Limited warranty parts and labor (1 year)  
See page 294 for additional warranty details.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
169  
VENTILATION ISLAND HOOD (42"/48"/54")  
Models: HNI42YS, HNI48YS, HNI54YS  
PERFORMANCE  
- 3 fan speeds plus 10 minute high-power operation mode  
- Filters are highly efficient at capturing grease  
- Powerfully quiet ventilation systems  
DESIgN  
- Brushed stainless steel finish  
- Welded, polished seams for a flawless design  
PROFESSIONAL  
HNI42YS – 42-Inch  
HNI48YS – 48-Inch  
HNI54YS – 54-Inch  
- 27-inch depth hood is a perfect companion to the Pro Grand®  
professional range  
- Premium electronic touch controls  
CONVENIENCE  
- Fluorescent lighting brightens the entire work space  
- Dishwasher safe aluminum mesh filters  
- After 40 hours of operation, the Clean Filter button illuminates  
- Telescopic chimney – adjustable at installation  
- Auto start High Heat Sensor  
- Delayed shutoff tackles lingering odors for up to 10 minutes  
- Blowers sold separately  
- Choose from Inline or Remote Blowers  
- Hood includes filters, lights, backdraft damper and transition  
SPECIFICATIONS  
Available Hood Widths 42", 48", 54"  
Blower  
Sold Separately—  
See Blower Options Table  
Duct Size at Discharge 8" Round  
Ducting Direction  
Ceiling Heights  
Vertical  
8 1/4 ft. to 10 ft.  
Dishwasher Safe Filters Mesh  
Halogen Lighting  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
170  
VENTILATION ISLAND HOOD (42"/48"/54")  
Models: HNI42YS, HNI48YS, HNI54YS  
INSTALLATION OPTIONS  
Thermador Professional Series Island Hoods may be installed  
above a Thermador Professional Cooktop or Range to create a  
convenient cooking center. Refer to the appropriate section for  
additional specifications.  
Hood installation height above a cooktop can vary. To obtain  
the necessary installation height above a Thermador Cooktop or  
Range, consult the appliance's installation manual.  
Thermador Island Hoods are suspended from the ceiling. These  
hoods are designed to be used for vertical discharge. A blower  
must be purchased separately.  
BLOWER OPTIONS  
REMOTE  
VTR1030D – 1000 CFM Use RFPLT1000  
in roof-mount applications  
VTR1330E – 1300 CFM Use RFPLT1000  
in roof-mount applications  
INLINE  
VTI1010D – 1000 CFM  
See page 145 for further details.  
REMOTE (Mounted to roof or external wall)  
REMOTE BLOWER ACCESSORIES  
RFPLT1000 – Roofplate Material  
VTR1330E 1300 CFM  
VTR1030D 1000 CFM  
For use with Remote Blowers VTR1030D and VTR1330E  
Combinations  
Roofplate  
Remote Blower  
RFPLT1000  
VTR1030D, VTR1330E  
Overall Dimensions  
Model No.  
A
B
C
Duct Size  
RFPLT1000  
9 3/8"  
12"  
11 1/8"  
10"  
INLINE (Mounted between kitchen and external wall)  
VTI1010D 1000 CFM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
171  
VENTILATION ISLAND HOOD WITH BLOWER (42")  
Model: HgSI42TS  
PERFORMANCE  
- 3 fan speeds  
- Filters are highly efficient at capturing grease  
- Powerfully quiet ventilation systems  
DESIgN  
- Brushed stainless steel finish  
- Welded, polished seams for a flawless design  
- Easy to operate control buttons  
CAPACITY  
- 400 CFM Integrated Blower included  
MASTERPIECE  
CONVENIENCE  
- Halogen lighting spotlights your best recipes  
- Dishwasher safe aluminum mesh filters  
- Telescopic chimney – adjustable at installation  
- Hood includes filters, lights, backdraft damper and transition  
HGSI42TS - 42-Inch  
SPECIFICATIONS  
Available Hood Widths 42"  
Blower  
400 CFM Blower Included  
Duct Size at Discharge 6" Round  
Ducting Direction  
Ceiling Heights  
Vertical  
8 ft. to 10 ft.  
Dishwasher Safe Filters Mesh  
Halogen Lighting  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
172  
VENTILATION ISLAND HOOD WITH BLOWER (42")  
Model: HGSI42TS  
INSTALLATION OPTIONS  
Thermador Masterpiece® Series Island Hoods may be installed  
above a Thermador non-professional gas, electric, or induction  
cooktop to create a convenient cooking center. Refer to the  
appropriate section for additional specifications.  
Hood installation height above a cooktop can vary. To obtain  
the necessary installation height above a Thermador Cooktop or  
Range, consult the appliance's installation manual.  
Thermador Island Hoods are suspended from the ceiling. These  
hoods are designed to be used for vertical discharge. A 400 CFM  
blower is included.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
173  
Download from Www.Somanuals.com. All Manuals Search And Download.  
48-Inch Pro Grand® ranGe Shown wIth cuStom VentIlatIon InSert  
174  
VENTILATION  
CUSTOM INSERTS  
Use Thermador Custom Hood Inserts within custom hood  
applications to create a seamless design with wall or island  
applications. These inserts efficiently and quietly remove odor  
and steam. Inserts are available for both professional and  
non-professional applications.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
175  
CUSTOM INSERTS FEATURES & BENEFITS  
REMOTE VENTILATION  
CONTROL  
Remote control for customized  
ventilation applications is easy to  
use and has a sophisticated and  
professional style. (VCI230DS,  
VCI236DS, VCI248DS only)  
HALOGEN LIGHTS  
Bright halogen lighting  
spotlights your best recipes.  
MESH FILTERS  
Aluminum mesh filters with  
stainless steel frame maximize  
grease capture without affecting  
flow and feature a quick release  
latch for easy clean-up.  
CUSTOM HOOD INSERT  
Specially designed for professional custom hood applications to create  
a concealed ventilation system.  
TIME-TO-CLEAN-FILTER LIGHT  
Easy cleanup: All Thermador ventilation filters are dishwasher safe,  
and many hoods feature a built-in Time-to-Clean-Filter reminder light.  
(VCI230DS, VCI236DS, VCI248DS only)  
DELAyED SHUTOFF  
For the greatest efficiency, our Professional ventilation models include  
delayed shutoff to tackle lingering odors. (VCI230DS, VCI236DS,  
VCI248DS only)  
PUSH BUTTON CONTROLS  
Concealed three-speed, push-button controls are easy to use.  
(Professional Series only)  
PLANNING INFORMATION  
MODEL OPTIONS  
ELECTRICAL SPECIFICATIONS  
Thermador Custom Hood Inserts are available for  
both professional and non-professional applications.  
The Professional Series Custom Hood Inserts are  
available in 30-inch, 36-inch and 48-inch widths.  
The Masterpiece® Series Custom Hood Inserts are  
available in 21-inch (for 30-inch wide installations)  
and 29-inch (for 36-inch wide installations).  
Be sure your Thermador Custom Insert is properly installed and grounded by  
a qualified technician. Installation, electrical connections and grounding must  
comply with all applicable local codes.  
MODEL  
REQUIRED CIRCUIT BREAKER  
120 V AC, 60 Hz  
VCI230DS, VCI236DS,  
VCI248DS, VCI21CS,  
VCI29CS  
15 Amp  
Download from Www.Somanuals.com. All Manuals Search And Download.  
176  
CUSTOM INSERTS PLANNING INFORMATION  
CHOOSING THE RIGHT CFM  
INSTALLATION CONSIDERATIONS  
The power of the cooktop or range, measured in BTU, is perhaps the most  
important factor in determining CFM needs for a hood. Professional Gas  
Cooktops generally should have 1 CFM for every 100 BTU. For Masterpiece®  
Electric and Induction Cooktops, and Gas Cooktops under 60,000 BTU,  
choose a blower with a minimum of 100 CFM per 12" of cooktop width.  
The information in this design guide provides  
key features, product dimensions and installation  
specifications. Before installing a Thermador Custom  
Hood Insert, be sure to verify the dimensions and  
electrical connections. Also, always consult with  
the installation manual packed with the product for  
complete details before installing.  
You should also consider the cooking space and cooking style of your client.  
• More demanding cooks usually require more exhaust capacity to handle  
moisture generated by boiling large pots of water or the grease and smoke  
resulting from grilling or frying. This cooking style could require a hood or  
downdraft system with airflow of 600 to 1,300 CFM.  
Professional Custom Series Hood Inserts are designed  
for installation with all professional-style cooktops and  
ranges. Masterpiece® Custom Series Hood Inserts are  
designed for installation with non-professional gas,  
electric or induction cooktops. Refer to the appropriate  
section for additional specifications.  
• For those who are used to preparing quick meals in a relatively small  
kitchen, a hood with 400 to 600 CFM may be adequate ventilation for the  
cooking space.  
HOOD WIDTH  
• If the cooking surface is in a peninsula or island, a larger capacity hood can  
provide better capture when there are cross currents and when the hood  
needs to be mounted higher. Downdraft ventilation systems are also a  
good alternative.  
The hood width should be no less than the width of the  
cooking surface. Where space is not restricted, a wider  
hood can be used to increase your capture area.  
• High heat cooking or aromatic foods may require additional CFM.  
Increasing capture area by 3" on each side is also a recommended way to  
address this issue.  
DISTANCE FROM COOKING SURFACE  
Proper mounting height is very important. If a hood  
is mounted too low, it may be difficult to cook and be  
unsafe. If a hood is mounted too high, performance  
may be compromised. For optimal performance, the  
distance from the cooking surface to the bottom of the  
hood should be a minimum of 30", unless otherwise  
noted. Please refer to the installation manual for each  
hood and cooktop/range model for proper hood  
mounting heights.  
LENGTH AND SIzE OF DUCTWORK  
Do not use flexible duct; it creates back pressure/air turbulence and reduces  
performance.  
Straight runs and gradual turns are best. Use the shortest route with the  
fewest turns possible.  
Proper performance is dependent upon proper ducting. Use a qualified and  
trained installer. Local building codes may require the use of make-up air  
systems when using ducted ventilation systems greater than specified CFM of  
air movement. The specified CFM varies from locale to locale. Consult your  
HVAC professional for specific requirements in your area.  
CHOOSING THE CORRECT BLOWER  
A variety of interior and exterior blower options  
Remote, Inline or Integral) are available for Thermadors  
Professional and Masterpiece® Series Hoods. If the unit  
you have selected does not have a blower included,  
one can be purchased separately. Blower selection  
will vary based on the volume of air that needs to be  
moved and the length and location of the duct run. For  
long duct runs with multiple turns and bends, consider  
using a more powerful blower. For the most efficient  
air flow exhaust, use a straight run or as few elbows as  
possible.  
If using a 10" duct, Thermador recommends not exceeding 150 feet of duct.  
Transitions, elbows and wall or roof caps are all factors that will add more  
static pressure, therefore increasing your equivalent duct run.  
Installation Note: Professional Rangetops and Ranges require that minimum  
distances be maintained from the cooking surface to combustible materials  
(i.e. a wood covering around the insert). These minimum distances range from  
30" to 40" and can vary from product to product and by manufacturer. Refer  
to the installation manual of the rangetop or range prior to the design and  
installation of the custom hood insert.  
Remote Blowers (VTR Series)  
Depending on your preference and ducting situation,  
these blowers can be mounted on the roof or exterior  
wall of your home. An exterior installation may be more  
appealing to reduce noise in the kitchen.  
WARRANTy  
Limited warranty parts and labor (1 year)  
Inline Blowers (VTI series)  
To minimize noise in the kitchen, these blowers are  
mounted along the duct line anywhere between the  
kitchen and the exterior wall. If you have easy access to  
your duct line (in an attic, for example), this may be an  
appealing option.  
See page 294 for additional warranty details.  
Integral Blowers (VTI series)  
These blowers are purchased separately and integrated  
into the hood or onto the downdraft unit at the time of  
installation. This option allows you to select your ideal  
hood with the exact power you require.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
177  
VENTILATION CUSTOM INSERT (30"/36"/48")  
Models: VCI230DS, VCI236DS, VCI248DS  
PERFORMANCE  
- 3 fan speeds  
- Filters are highly efficient at capturing grease  
- Powerfully quiet ventilation systems  
- Deep capture area allows for efficient capture of smoke and steam  
DESIGN  
- Suitable for wall or island applications  
- Stainless steel button controls  
CONVENIENCE  
- Halogen lighting spotlights your best recipes  
- Dishwasher safe aluminum mesh filters  
- All-stainless steel baffle filters are available  
- Built-in Clean Filter Reminder light  
PROFESSIONAL  
VCI230DS – 30-Inch  
VCI236DS – 36-Inch  
VCI248DS – 48-Inch  
- Delayed shutoff tackles lingering odors for up to 10 minutes  
- Blowers sold separately  
- Choose from Inline, Remote or Integrated Blowers  
Custom hood insert for use within wall or island custom  
hood applications  
REMOTE CONTROL PANELS  
SPECIFICATIONS  
Available Hood Widths 30", 36", 48"  
VCI2REMFS/VCI2REM  
Blower  
Sold Separately—  
See Blower Options Table  
- Overall size: 14 1/2" W x 4 1/2" H  
- For use with VCI2__DS  
Duct Size at Discharge 10" Round  
Ducting Direction Vertical  
- Stainless steel finish  
- Cable-connected to blower and hood controls  
- Choose from one of two unique styles  
Dishwasher Safe Filters Mesh (Baffle filters sold as  
an accessory)  
VCI2REM  
VCI2REMFS  
Halogen Lighting  
30", 36" – 2 Bulbs  
48" – 4 Bulbs  
14 1/2"  
4 1/2"  
ACCESSORIES  
BAFFLT – Baffle Filters  
LINER – Custom Hood Liners  
(30"/36"/48") BAFFLT30/BAFFLT36/BAFFLT48  
(30"/36"/48") LINER30/LINER36/LINER48  
- For use with VCI2__DS  
- Stainless steel finish  
- For use with VCI2__DS  
- Stainless steel custom hood liners  
to protect the exterior base of  
custom insert  
- Unique low profile design maximizes  
grease capture  
- Custom hood liner completes  
custom insert installation  
- Dishwasher safe for easy clean-up  
Download from Www.Somanuals.com. All Manuals Search And Download.  
178  
VENTILATION CUSTOM INSERT (30"/36"/48")  
Models: VCI230DS, VCI236DS, VCI248DS  
INSTALLATION OPTIONS  
Thermador Custom Hood Inserts within custom hood applications create a  
seamless design with wall or island applications.  
Thermador Professional Series Custom Hood Inserts may be installed above  
a Thermador Professional Cooktop or Range to create a convenient cooking  
center. Refer to the appropriate section for additional specifications.  
Hood installation height above a cooktop can vary. Professional Rangetops  
and Ranges require that minimum distances be maintained from the cooking  
surface to combustible materials (i.e. a wood covering around the insert). These  
minimum distances range from 30" to 40" and can vary from product to product  
and by manufacturer. Refer to the installation manual of the rangetop or range  
prior to the design and installation of the custom hood insert.  
These hoods are designed to be used for vertical discharge. A blower must be  
purchased separately.  
BLOWER OPTIONS  
REMOTE  
VTR630D – 600 CFM  
Use RFPLT600 in roof-mount applications  
VTR1030D – 1000 CFM Use RFPLT1000 in roof-mount applications  
VTR1330E – 1300 CFM Use RFPLT1000 in roof-mount applications  
INLINE  
Installation Note: Professional Rangetops and Ranges require  
that minimum distances be maintained from the cooking  
surface to combustible materials (i.e. a wood covering around  
the insert). These minimum distances range from 30" to 40"  
and can vary from product to product and by manufacturer.  
Refer to the installation manual of the rangetop or range prior  
to the design and installation of the custom hood insert.  
VTI610D – 600 CFM  
VTI1010D – 1000 CFM  
INTEGRATED  
VTI610D – 600 CFM  
Inline blower can be used for an integrated  
solution  
See page 145 for further details.  
REMOTE (Mounted to roof or external wall)  
VTR630D 600 CFM VTR1030D 1000 CFM  
REMOTE BLOWER ACCESSORIES  
VTR1330E 1300 CFM  
RFPLT600, RFPLT1000 – Roofplate Material  
For use with Remote Blowers VTR630D, VTR1030D  
and VTR1330E  
Combinations  
Roofplate  
RFPLT600  
RFPLT1000  
Remote Blower  
VTR630D  
VTR1030D, VTR1330E  
Overall Dimensions  
Model No.  
A
B
C
Duct Size  
6"  
INLINE (Mounted between kitchen and external wall) INTEGRAL (Mounted on hood)  
VTI610D 600 CFM  
RFPLT600  
7 1/2" 8 1/2" 9 1/4"  
12" 11 1/8"  
RFPLT1000 9 3/8"  
10"  
VTI610D 600 CFM  
VTI1010D 1000 CFM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
179  
VENTILATION CUSTOM INSERT WITH BLOWER (21"/29")  
Models: VCI21CS, VCI29CS  
PERFORMANCE  
- 3 fan speeds plus 10 minute high-power operation mode  
- Filters are highly efficient at capturing grease  
- Powerfully quiet ventilation systems  
DESIGN  
- Suitable for wall or island applications  
- Slide control for easy power adjustments  
CAPACITy  
- 400 CFM Integrated Blower included  
MASTERPIECE  
VCI21CS – 21-Inch  
CONVENIENCE  
VCI29CS – 29-Inch  
- Halogen lighting spotlights your best recipes  
- Dishwasher safe aluminum mesh filters  
- Hood includes filters, lights, backdraft damper and transition  
Custom hood insert for use within custom hood applications  
SPECIFICATIONS  
Available Hood Widths 21", 29"  
Installation Width  
21" Model – Up to 30" Wide  
29" Model – Up to 36" Wide  
Blower  
400 CFM Blower Included  
Duct Size at Discharge 6" Round  
Dishwasher Safe Filters 2 Mesh  
Halogen Lighting  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
180  
VENTILATION CUSTOM INSERT WITH BLOWER (21"/29")  
Models: VCI21CS, VCI29CS  
INSTALLATION OPTIONS  
Thermador Custom Hood Inserts within custom hood  
applications create a seamless design with wall or island  
applications.  
Thermador Masterpiece® Series Custom Hood Inserts may be  
installed above a Thermador non-professional gas, electric, or  
induction cooktop up to 36-inches wide to create a convenient  
cooking center. Refer to the appropriate section for additional  
specifications.  
Hood installation height above a cooktop can vary. To obtain  
the necessary installation height above a Thermador Cooktop,  
consult the appliance's installation manual.  
These hoods are designed to be used for vertical discharge.  
A 400 CFM Blower is included.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
181  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DOWNDRAFT MODEL UCVM36FS SHOWN WITH 36-INCH INDUCTION COOKTOP CIT365GM  
182  
VENTILATION  
DOWNDRAFT  
If you prefer a concealed look, choose a Thermador Downdraft  
Ventilation Unit, which offers space efficiency when a hood is not  
preferred. A full face filter combines a filter with splatter shield  
in one easy-to-remove, dishwasher-safe element. Thermador  
invented the first retractable downdraft, and was also the first  
to introduce a recirculation option for downdrafts—making  
ventilation possible in any kitchen.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
183  
DOWNDRAFT FEATURES & BENEFITS  
FULL 13-INCH RISE  
With an over 13-inch intake, the UCVM rises well above even the tallest  
pans. This protects against splatters when cooking and provides better  
performance in capturing steam and smoke—even from the front burners.  
DOWNDRAFT RECIRCULATION OPTION  
Downdraft recirculation is now available for island or wall applications.  
Combine the performance of the UCVM Downdraft with the odor- and  
grease-capturing filters in the Recirculation Module for the perfect  
ventilation combination for anywhere in your kitchen.  
FULL FACE FILTERS  
Full-face filters combine a filter with a splatter shield in one easy-to-  
remove, dishwasher-safe element. These filters maximize grease capture  
without affecting airflow.  
PLANNING INFORMATION  
Thermador Downdraft Hoods may be installed in a wall or island behind a  
Thermador non-professional gas, electric or induction cooktop to create a  
convenient cooking center. Refer to the appropriate section for additional  
specifications.  
MODEL OPTIONS  
Thermador Downdraft Hoods are available in 30  
and 36-inch widths to fit your kitchen plans and are  
meticulously crafted for both function and design. Be  
sure to reference the correct model information in this  
design guide.  
HOOD WIDTH  
Downdraft ventilation units should be the same width as the cooking surfaces  
they are ventilating.  
ELECTRICAL SPECIFICATIONS  
CHOOSINg THE CORRECT BLOWER  
Be sure your Thermador Downdraft Hood is properly  
installed and grounded by a qualified technician.  
Installation, electrical connections and grounding must  
comply with all applicable local codes.  
A variety of interior and exterior blower options (Remote, Inline or Integral)  
are available for Thermadors Downdraft Hoods. If the unit you have selected  
does not have a blower, one can be purchased separately. Blower selection  
will vary based on the volume of air that needs to be moved and the length  
and location of the duct run. For long duct runs with multiple turns and  
bends, consider using a more powerful blower. For the most efficient air flow  
exhaust, use a straight run or as few elbows as possible.  
REQUIRED  
MODEL  
CIRCUIT BREAKER  
120V AC, 60 Hz  
15 Amp  
Remote Blowers (VTR Series)  
UCVM30FS, UCVM36FS  
Depending on your preference and ducting situation, these blowers can be  
mounted on the roof or exterior wall of your home. An exterior installation  
may be more appealing to reduce noise in the kitchen.  
INSTALLATION CONSIDERATIONS  
Inline Blowers (VTI series)  
The information in this design guide provides key  
features, product dimensions, cutouts and installation  
specifications. Before installing a Thermador Downdraft  
Hood, be sure to verify the cutout dimensions and  
electrical connections. Also, always consult with  
the installation manual packed with the product for  
complete details before installing.  
To minimize noise in the kitchen, these blowers are mounted along the  
duct line anywhere between the kitchen and the exterior wall. If you have  
easy access to your duct line (in an attic, for example), this may be an  
appealing option.  
Integral Blowers (VTN series)  
These blowers are purchased separately and integrated into the hood or onto  
the downdraft unit at the time of installation. This option allows you to select  
your ideal hood with the exact power you require.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
184  
DOWNDRAFT FEATURES & BENEFITS  
CHOOSINg THE RIgHT CFM  
BLOWER OPTIONS  
The power of the cooktop, measured in BTU, is  
perhaps the most important factor in determining  
CFM needs for a hood. Professional Gas Rangetops  
generally should have 1 CFM for every 100 BTU.  
REMOTE  
Requires CV2T6 Transition  
VTR630D – 600 CFM  
VTR1030D – 1000 CFM  
INLINE  
Use RFPLT600 in roof-mount applications  
Use RFPLT1000 in roof-mount applications  
Requires CV2T6 Transition  
You should also consider the cooking space and  
cooking style of your client.  
VTI610D – 600 CFM  
VTI1010D – 1000 CFM  
INTEgRATED  
• More demanding cooks usually require more  
exhaust capacity to handle moisture generated  
by boiling large pots of water or the grease  
and smoke resulting from grilling or frying. This  
cooking style could require a hood or downdraft  
system with airflow of 600 to 1,300 CFM.  
VTN600CV2C – 600 CFM  
See page 145 for further details.  
REMOTE (Mounted to roof or external wall)  
INTEgRAL (Mounted on hood)  
• For those who are used to preparing quick  
meals in a relatively small kitchen, a hood with  
600 CFM may be adequate ventilation for the  
cooking space.  
VTR630D 600 CFM VTR1030D 1000 CFM  
VTN600CV2C 600 CFM  
• If the cooking surface is in a peninsula or island, a  
larger capacity hood can provide better capture  
when there are cross currents and when the  
hood needs to be mounted higher. Downdraft  
ventilation systems are also a good alternative.  
• High heat cooking or aromatic foods may require  
additional CFM. Increasing capture area by 3" on  
each side is also a recommended way to address  
this issue.  
INLINE (Mounted between kitchen and external wall)  
VTI610D 600 CFM VTI1010D 1000 CFM  
LENgTH AND SIzE OF DUCTWORK  
Do not use flexible duct; it creates back pressure/air  
turbulence and reduces performance.  
Straight runs and gradual turns are best. Use the  
shortest route with the fewest turns possible.  
Proper performance is dependent upon proper  
ducting. Use a qualified and trained installer. Local  
building codes may require the use of make-up  
air systems when using ducted ventilation systems  
greater than specified CFM of air movement. The  
specified CFM varies from locale to locale. Consult  
your HVAC professional for specific requirements in  
your area.  
REMOTE BLOWER ACCESSORIES  
RFPLT600, RFPLT1000 – Roofplate Material  
For use with Remote Blowers VTR630D and VTR1030D  
If using a 10" duct, Thermador recommends not  
exceeding 150 feet of duct. Transitions, elbows and  
wall or roof caps are all factors that will add more  
static pressure, therefore increasing your equivalent  
duct run.  
Combinations  
Roofplate  
RFPLT600  
RFPLT1000  
Remote Blower  
VTR630D  
VTR1030D  
Overall Dimensions  
WARRANTY  
Model No.  
A
B
C
Duct Size  
Limited warranty parts and labor (1 year)  
RFPLT600  
7 1/2" 8 1/2" 9 1/4" 6"  
RFPLT1000 9 3/8"  
12" 11 1/8"  
10"  
See page 294 for additional warranty details.  
CV2T6 TRANSITION  
Transition piece required for installation of inline and  
remote blowers – downdraft applications only  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
185  
ventILatIon DoWnDraft (30"/36")  
models: Ucvm30fS, Ucvm36fS  
performance  
- 3 fan speeds  
- Filters are highly efficient at capturing grease  
- Powerfully quiet ventilation systems  
DeSIGn  
- Suitable for wall or island applications  
- Brushed stainless steel finish  
- Easy to operate control buttons  
maSterpIece  
UCVM30FS – 30-Inch  
UCVM36FS – 36-Inch  
capacIty  
- Downdraft rises over 13 inches to capture steam from the  
tallest pots  
- Downdraft recirculation possible with module RECIRC36DF  
convenIence  
- Dishwasher safe full-face filters also act as a splatter shield  
- Blowers sold separately  
- Choose from Inline, Remote or Integrated Blowers  
SpecIfIcatIonS  
Available Hood Widths 30", 36"  
Blower  
Sold Separately—  
See Blower Options Table  
Duct Size at Discharge 6" Round  
Ducting Direction  
Down, Left or Right  
Dishwasher Safe Filters Full-Face Mesh  
acceSSorIeS  
ø 53/4”  
181/8”  
recIrc36Df – Recirculation Kit  
- For use with UCVM__FS  
11/8”  
4”  
171/8”  
- Comes complete with 2 charcoal filters, 2 venting grids, and ducting  
to transition to integrated blower (blower sold separately)  
15/8”  
51/8”  
197/8”  
191/8”  
- For toe kick heights of 4 inches or taller  
201/4”  
- Wall or island applications  
- Easily mounts to integrated blower (VTN600CV2C) under cooktop  
- Toe kick/socket can be vented in any direction  
- Mounts to base of cabinet; recesses into toe kick  
- To be used only with Thermador downdraft and integrated blower  
211/4”  
31/2”  
repLacement cHarcoaL fILterS  
Sold Separately as a Service Item (For use with Recirculation Module)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
186  
VENTILATION DOWNDRAFT (30"/36")  
Models: UCVM30FS, UCVM36FS  
INSTALLATION OPTIONS  
The Thermador Downdraft Hood System is available in 30-inch  
or 36-inch widths. It is intended for installation with Thermador  
non-professional gas, electric or induction cooktops only.  
A Recirculation Kit (RECIRC__FS) can be purchased separately and  
used in conjunction with the Integral Blower if ducting to the outside  
is not a viable option. Refer to the appropriate section for additional  
specifications.  
These hoods are designed to be used for vertical or horizontal discharge.  
21/4"  
Dimension  
depends  
on Countertop  
min.1/4"  
1/4"  
51/16"  
21/4"  
6"  
91/8"  
Dimension  
depends  
on Cabinet  
215/8"  
143/4"  
Blower/Duct  
Transition Box  
ø6"  
Vent  
31/4"  
65/16"  
10"  
Center Line (CL)/  
Plumbline  
Cutout and  
Overall  
Dimensions  
93/4"  
Point "P"  
1/2"  
wide 31": 283/8"  
wide 37": 343/8"  
21/4"  
151/2"  
CL  
A
63/8"  
BT  
Cutout and  
Overall  
Dimensions  
CL  
17/8"  
B
min.  
1/4"  
CL  
A
B
SB  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.800.735.4328 THERMADOR.COM  
|
187  

Thermo Products Furnace CDB 100N User Manual
TOA Electronics Ventilation Hood SSDV 3328 User Manual
Toshiba Air Conditioner RAV SM1104BT E User Manual
Toshiba Electronic Keyboard Electric Keyboard User Manual
Toshiba Flat Panel Television L43 User Manual
Ultra electronic Printer XID570ie User Manual
Uniden Scanner BC796D APC0 25 User Manual
Uniden Scanner UBC3500XLT User Manual
Univex Automobile 2011 Titan User Manual
ViewSonic Flat Panel Television VX912 User Manual