MetroLinks Distribution Cabinet
(MDC-CB)
User Manual 131220 A0
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
1. Description
MDC-CB Without Rear Compartment Splicing................................................................................................ 1-3
MDC-CB With Rear Compartment In-Cabinet Splicing .................................................................................. 1-4
Features ......................................................................................................................................................... 1-6
Benefits .......................................................................................................................................................... 1-6
Specifications & Capacities ............................................................................................................................ 1-6
2. Cabinet Installation
Installation Considerations ............................................................................................................................. 2-1
Pre-Installation ............................................................................................................................................... 2-1
Location & Layout — ............................................................................................................................... 2-1
Tools & Equipment — ............................................................................................................................. 2-3
Inspection ....................................................................................................................................................... 2-3
3. Cabling Without In-Cabinet Splicing
Feeder Cable Installation ............................................................................................................................... 3-1
Patch Module & Distribution Cable Installation .............................................................................................. 3-4
4. Cabling With In-Cabinet Splicing
Splice Box Installation .................................................................................................................................... 4-1
Patch Module Installation ............................................................................................................................... 4-1
Feeder Cable Installation ............................................................................................................................... 4-3
5. Cross Connections
6. Service
Technical Support ........................................................................................................................................... 6-1
7. Accessories
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved • Telect Publication 125147-3 A0
Download from Www.Somanuals.com. All Manuals Search And Download.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2006 Telect, Inc., All Rights Reserved
Page iv
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Description
Telect’s MDC-CB is an indoor/outdoor fiber telecommunication distribu-
tion cabinet. The cabinet houses Telect’s bulkhead-style Patch Modules to
handle optical signal distribution between a CO and the network edge. A
single MDC-CB cabinet with up to six Telect Patch Modules can provide
distribution service to 432 homes, offices and/or nodes.
Cabinet
The weather-tight, heavy-gauge, light-weight aluminum cabinet is almond with
two lockable doors — both doors have wind stays. OSP feeder and distribution
cable enter through weather-tight cable clamps at the bottom of the rear com-
partment:
Illustrations that follow depict open-door views of MDC-CB cabinets with and
without in-cabinet splicing.
Along with the cabinet, Telect includes a footprint template which is also the iso-
3
lation pad, two cable entrance clamps for two feeder cables between /8 in. (9.6
1
9
mm) and 1 /5 in. (30.5 mm) in diameter, and a /32 in. Allen-head key for open-
ing the door latches. The MDC-CB includes a 6-in. base. A 12-in. Telect base
(Model MDC-R12) is optional.
Physically, the only difference between MDC-CB cabinets with or without splic-
ing is the splice box on the rear door. Feeder and distribution cabling for the two
is, however, quite different.
Base
Distribution Adapters
Feeders to Front
Compartment
Feeder & Distribution
Cable Entrances
Lances for Anchoring Cable
& Subunits
MDC-CB Without In-Cabinet Splicing (Rear Corner View)
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved • Telect Publication 131220 A0
Download from Www.Somanuals.com. All Manuals Search And Download.
Distribution Adapters
Feeders to Front
Compartment
Model MDC-SPLC
Splice Box
Feeder & Distribution
Cable Entrances
Lances for Anchoring Cable,
Subunits, and Loose Tubing
MDC-CB With In-Cabinet Splice Box (Rear Corner View)
Parking for Unassigned
Distribution
Feeders from Rear
Compartment to Splitters
Splitters in Splitter
Bulkhead
Adapters for Assigned Distribution
Front Corner View With Door Open
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 1-2
Download from Www.Somanuals.com. All Manuals Search And Download.
.MDC-CB WITHOUT REAR COMPARTMENT SPLICING
Cabling without in-cabinet splicing involves an aerial or below-ground splice box for splicing the distribution and feeder cables to
connectorized cabinet cabling.
•
At the cabinet, the OSP distribution cable is clamped at the floor of the rear compartment and then routed along the cabi-
net’s compartment partition. The connectorized 250 µm strands break out here into subunits/buffers and then connected to
one of the six possible, 72-channel Patch Modules. Each patch module contains SC/APC adapters to interface the distribu-
tion fiber in the rear compartment to the cross connections in the front compartment.
•
Feeder cable is anchored along the rear side wall where 900 µm fiber breaks out into subunits/buffers and routed to 16
SC/APC interface adapters near the top of the cabinet.
Subunit/Buffer
From Feeder
Cable Breakout
to Rear-Side
Feeder
Adapters
Feeders
Unassigned
Distribution
(Parking)
Fiber Furcated
From Multifiber
Buffer to
900-µm Single
Fiber Loose
Tubing
Assigned
Distribution
to Subscriber
OSP
Distribution
Cable
OSP Feeder
Cable
Splitter
Bulkhead
Splitter Module
2 mm Jumpers
*
*
Rear View With Door Open
Front View With Door Open
* Splitter and Patch Modules are sold separately.
Each SC/APC adapter at the top of the cabinet serves to feed the fiber signal to a blue jumper in the front compartment, shown in the
preceding illustration. The blue jumper is routed down through the right portion of the front compartment, then around a couple of
spools and an arc. The two spools at the bottom route the blue fiber to a Telect Splitter Module.
Up to 18, 1x4, 1x8, 1x16, or 1x32 Telect Splitter Modules can be installed in the splitter bulkhead at the bottom of the front compart-
ment. Each splitter module consists of the splitter, one blue “input” jumper, and either 4, 8, 16, or 32 yellow “output” jumpers. All are
2 mm jumpers, 2.1 m in length.
Splitter module installation and all of the distribution changes occur in this front compartment:
•
•
Unassigned jumpers are routed via spools and arcs to a parking station for later subscriber assignment.
Assigned jumpers are routed via the spools and arcs to the front of the SC/APC adapters in the front of the patch modules
for cross connection to the distribution fiber connected to the rear of the patch modules.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Each of the six possible patch modules (Model MDC-P72N) features 72 SC/APC cross-connect adapters for a total of 432 possible
subscriber cross connections. Model MDC-P72N-F100D includes the Model MDC-P72N connected to 100 ft (~30.5 m) of Dri-Flex™
OSP cable containing 250 µm fiber furcated to 900 µm loose tubing with an SC/APC connector.
The following illustration shows a deployed cabinet along with a partially cabled rear compartment.
Rear of Patch Module
Bar for Grounding
Single-Armored Cable
Two Cable Entrance Clamps
Are Included With Cabinet
To Accommodate
Two Feeder Cables*
One Cable Entrance Clamp
For a Distribution Cable*
Is Included With The
Patch Module
Anchors & Conduit Are
Not Included With Cabinet.
Concrete Pad
* Cable Entrance Clamps Accommodate
Cable Between 3/8 in. & 1-1/5 in.
4-in. Conduits
In Dia. Additional clamps
are available.
MDC-CB WITH REAR COMPARTMENT IN-CABINET SPLICING
The distribution and feeder OSP enter the cabinet at the floor of the rear compartment. The installer clamps the cable and breaks out
the fiber into 3-mm, radius-control (limited bend) loose tubing. The installer anchors feeder and distribution tubes along the cabinet’s
side wall and rear door.The tubes are guided to the top of the optional splice box located on the door.
The optional in-cabinet Telect Splice Box (Model MDC-SPLC) holds three pods of splice cassettes surrounded by a runway for the
loose tubing.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 1-4
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
Each cassette normally accommodates 24 splices. If all feeder and distribution fiber requires splicing, a total of 18 cassettes are
needed to accommodate all 432 subscribers. For the distribution splices, each pod would hold 6 splice cassettes plus one additional
cassette on one of the pods for up to 16 feeder splices.
Feeder and distribution strands are spliced to connectorized fiber protected by 3-mm, radius control loose tubing. All tubing from the
cassettes to the feeder interface and patch modules cross the door hinge near the top of the cabinet. The tubing is anchored along
the compartment partition and guided to SC/APC feeder or distribution adapters:
•
The feeder interface near the top, rear-side of the cabinet contains 16 adapters to pass feeder signals to the front compart-
ment splitters.
•
The distribution adapters are located on 72-port modules (Models MDC-P72N). Fan-out blocks on the Patch Modules are
used to accommodate the transition from 3-mm, multi-fiber loose tubing to 900 µm transparent tubes, one for each of the
72 fibers. A total of 6 Patch Modules accommodate the 432 possible subscribers. The SC/APC adapters pass signals to the
front compartment for assignment patching.
Loose Tubing
From Splice
Box to
Rear-Side
Feeder
Adapters
Feeders
Unassigned
Distribution
(Parking)
Loose Tubing
From Splice Box
to Rear-Side
Distribution
Adapters
Fiber Furcated
From 3-mm
Multifiber Loose
Tubing to
900-µm Single
Fiber Loose
Tubing
Assigned
Distribution
to Subscriber
Loose Tubing
From Feeder
Cable to Splice
Box
Loose Tubing
From Distribution
Cable to Splice
Box
Splitter
Bulkhead
Splitter Module
2 mm Jumpers
OSP Feeder
Cable From CO
OSP Distribution
Cable
*
*
Rear View With Door Open
Front View With Door Open
* Splitter Modules, Patch Modules, Splice Box, Splice Cassettes, Fan-Out Blocks, and Radius-Control Loose Tubing are Sold Separately.
FRONT COMPARTMENT CROSS CONNECTIONS
Front compartment feeder and cross-connect cabling is the same for cabinets with or without in-cabinet splicing.
Each SC/APC adapter at the top of the cabinet serves to feed the fiber signal to a blue jumper in the front compartment. The blue
jumper is routed down through the right portion of the front compartment, then around a couple of spools and an arc. The two spools
at the bottom route the blue fiber to a Telect Splitter Module.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 1-5
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
Up to 18, 1x4, 1x8, 1x16, or 1x32 Telect Splitter Modules can be installed in the splitter bulkhead at the bottom of the front compart-
ment. Each splitter module consists of the splitter, one blue “input” jumper, and either 4, 8, 16, or 32 yellow “output” jumpers. All are
2 mm jumpers, 2.1 m in length.
Splitter module installation and all of the distribution changes (patching) occur in this front compartment:
•
•
Unassigned jumpers are routed via spools and arcs to a parking station for later subscriber assignment.
Assigned jumpers are routed via the spools and arcs to the front of the SC/APC adapters in the front of the patch modules
for cross connection to the distribution fiber connected to the rear of the patch modules.
FEATURES
•
•
Simple cabling scheme. Separate compartments for OSP cable (feeder & distribution at the rear) with splitter growth and
cross-connections at the front
Patch module bulkhead swings out into front compartment for convenient adapter and connector inspection and mainte-
nance
•
•
•
•
•
•
•
30 mm (min.) bend radius control throughout cabinet & accessories
Highest splitter density — up to 32 splits per splitter module
Expandable. Easily add splitter modules as distribution grows
Popular bulkhead-style modular distribution (up to 6, 72-channel patch modules)
Bulkhead-style splitter bank for up to 18 Splitter Modules containing 1x4, 1x8, 1x16, or 1x32, premium PLC splitters
Laser eye protection throughout. All adapters and connectors include dust caps
Front & rear padlockable doors with wind strays (padlocks not included). Routing guide and designation chart located con-
veniently on inside of front door.
•
Includes grounding bar for armored cable.
BENEFITS
•
•
•
•
•
•
•
Low cost — High Fiber Density — Versatility
Better access — full front and rear doors open wide for simple access and installation
Simple Site Prep
Easy Installation. Ideal for both local and remote sites
Designed for compliance: NEMA 4, GR-771, GR-487
Designed & Built for Growth
Simple, straight-forward cable management, access, circuit identification.
SPECIFICATIONS & CAPACITIES
•
•
•
Dimensions (Overall WxHxD): 28 x 54 x 18 in (710 x 1375 x 460 mm). See the following for detailed dimensions.
Weight (without modules, accessories, or cabling): ~125 lb (~60 kg).
Feeder & Distribution Cable Entrance Positions/Capacity: 16
3
1
•
Cable Diameter: /8 in. (9.6 mm) to 1 /5 in. (30 mm), max.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 1-6
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
•
•
Fiber Signals: 16 feeder signals, max.; 432 distribution signals, max.
Adapters: SC/APC at cabinet end of fibers
Cross-Connect Bulkhead Positions: 6, max. Each bulkhead accommodates 72 X-connects (6 x 72 = 432)
Splitter Module Positions: 18, max. Each accommodates a 1x4, 1x8, 1x16 or 1x32 Telect Splitter Modules with front
access installation and cabling. “Inputs” and “outputs” are 2-mm jumpers, 2.1 m long with SC/APC connectors
•
Parking Positions: 72, max., to accommodate unassigned split-
ter “outputs”
•
•
Cabinet Material: 0.125 in, 5052 Aluminum
Cabinet Finish: Powder-coat almond
30.74 [780.9]
24.87 [631.7]
27.86 [707.7]
0.64 [16.2]
18.94 [481.0]
18.00 [457.2]
67.79 [1721.9]
2.72 [69.1]
24.92 [633.0]
28.31 [719.0]
51.24 [1301.4]
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 1-7
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 1- 8
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Cabinet Installation
INSTALLATION CONSIDERATIONS
WARNING
!
WARNING! Fiber cables transmit invisible infrared light. To avoid eye damage or blindness, never look directly
into fibers or connectors.
WARNUNG! Faserkabel übertragen unsichtbares Infrarotlicht. Um eine Schädigung der Augen oder Blindheit
zu vermeiden, schauen Sie nicht direkt in die Fasern oder Stecker.
ADVERTENCIA ! Los cables de fibra transmiten luz láser o infrarroja invisible. Para evitar lesiones oculares o
ceguera, nunca mire directamente a las fibras o conectores.
AVERTISSMENT ! Les câbles à fibres transmettent un rayon laser ou une lumière infrarouge invisible. Pour
éviter toute lésion occulaire ou cécité, ne regardez jamais directement dans les fibres ou dans les
connecteurs.
ALERT
!
ALERT! This product must be installed and maintained only by qualified technicians.
ALERT
!
ALERT! These instructions presume you have verified that the Telect equipment being installed is compatible
with the rest of the system, including power, ground, circuit protection, signal characteristics, equipment from
other vendors, and local codes or ordinances.
PRE-INSTALLATION
Location & Layout —
Use the floor template (isolation pad), or the following illustration, to lay out and construct a re-enforced concrete pad, grating, or
other suitable, stable platform to accommodate the cabinet, anchorage, and cabling. Concrete pads must be at least 6 in. (~150
mm) thick.
Telect does not include an anchor kit or a vault-to-cabinet adapter with the cabinet. Order Telect’s seismic anchor kit (Model
MDC-CBAK) for either indoor or outdoor deployment on concrete. (See “Standard Accessories” Page 7-1.) Model MDC-CBAK
is an expansion-style anchor requiring drilling into the pad; also acceptable are embed L-shaped anchors with ½ in. (M12)
threads, available at appropriate hardware or specialty stores.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved • Telect Publication 131220 A0
Download from Www.Somanuals.com. All Manuals Search And Download.
22.09 [561.0]
19.90 [505.5]
17.72 [450.0]
15.53 [394.5]
NOTE: Dimensions are in in. (mm)
Cable Clamp
Positions (16)
11.89 [302.0]
9.70 [246.5]
7.52 [191.0]
5.33 [135.5]
REAR
1.75 [44.5]
1.28 [32.5]
2.79 [70.8]
Ø1.20 [Ø30.5]
Max. Cable Dia.
14.29 [363.0]
Footprint
16.85 [428.0]
10.79 [274.0]
5.41 [137.5]
Ø0.50 [Ø12.7]
Anchor Holes
1.28 [32.4]
1.75 [44.5]
1.99 [50.6]
FRONT
1.99 [50.6]
23.52 [597.4]
27.50 [698.5] Footprint
20.99 [533.2]
18.81 [477.7]
16.62 [422.2]
10.80 [274.2]
Conduit Positions
Vs Cable Clamp
Positions
Ø4.00 [Ø101.6] Stub-Up Conduit
8.61 [218.7]
6.43 [163.2]
REAR
3.66 [93.0]
FRONT
Please note the following recommendations:
•
Telect recommends that the cabinet be mounted with either the 6-in.-high base or optional 12-in.-high base (Models MDC-
R12) or a suitable vault, along with the isolation pad included with the cabinet. (See “Standard Accessories” Page 7-1.) If
the cabinet is mounted to a concrete pad without a pedestal or vault, the stub-up conduit for the cables must be positioned
accurately and must be either absolutely flush with or countersunk below the top of the pad.
•
•
For a cabinet with a Telect base, the stub-up conduit should not rise above a concrete pad more than about 3 in. (~75 mm)
for a 6-in.-high base and about 6 in. (~150 mm) for a 12-in.-high base. See the following illustration.
Telect recommends running cables in 4-in. stub-up conduit. Normally, two 4-in. conduits are necessary: one for the feeder
cable(s) and at least one for the distribution cable(s), as shown in the illustration that follows. Prefer to run feeder cable as
close as possible to the grounding bar — regardless if feeder is armored or unarmored.
•
•
Don’t forget to make room for growth. Add additional 4-in. conduit and cap off the end(s) at the edge of or beyond the pad.
Telect recommends anchors at all four corners. Upper end of anchor bolts must extend between 1¼ in. and 1½ in. above
top of pad, grating, or platform.
•
For outdoor deployment, Telect recommends that, in addition to the isolation pad provided with the cabinet, that the cus-
tomer plan for and provide a suitable water-tight gasket between the bottom of the cabinet and the pad. Use the preceding
illustration to mark and cut a rectangular hole for cable entrance.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 2-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Tools & Equipment —
No special tools required for installation.
INSPECTION
Telect is not liable for shipping damage.
Keep the container until you have checked equipment operation. If you experience any kind of problem, call Telect’s Customer Ser-
vice Department. Use the original, undamaged container if you are instructed to return a panel to Telect.
If a shipping container is damaged, keep it for the carrier’s inspection. Notify the carrier and call Telect’s Customer Service Depart-
ment at 1-800-551-4567 or 1-509-926-6000
INSTALLATION PROCEDURE
Please read these instructions carefully before beginning installation. If you need assistance call Technical Support at 888-821-4856
(domestic calls), or 509-921-6161 (Option 2), or eMAIL us at getinfo@telect.com
1. Inspect equipment after unpacking and compare it to the packing list.
Immediately report any shipping damage, defects, or missing parts to
Telect at 1-800-551-4567. Keep all documentation that comes with your
Re-Orient Rings
to Lift Cabinet
shipment.
2. Remove lifting rings at top of cabinet and then resecure as shown on the
Lifting Ring Orientation
right.
(As Shipped)
3. Before moving cabinet, make sure the pad, grating, vault, or other support
is ready: namely,
•
If installation includes a vault, make sure vault-to-cabinet adapter is
in place.
•
If using Telect’s seismic anchor kit (Model MDC-CBAK), install anchors, as fol-
lows:
Torque Nuts With Red Plastic Collar
Round Washer
25
a. Drill an 18 mm ( /32-in.) diameter hole, 100 to 115 mm (4¼ to 4½ in.) deep,
Square Washer
Metal Sleeve
at each of the four anchor locations.
b. Clean out holes using a shop vacuum, compressed air, or blow-out bulb.
Clean away debris.
c. Place round washer on rod and then thread torque nut onto the rod. The
washer should touch the top of the metal sleeve.
Plastic Guide
d. Insert anchor assembly (without the square washer) into hole. Tap anchor
rod down with a hammer until washer touches the concrete.
Expansion Sleeve
e. Pre-torque anchoring nuts to approximately 30 ft-lb (~40 N•m) using a ¾ in.
(19 mm) socket or box wrench.
Do not overtighten. Over-tightening will cause the torque nut to prematurely
shear off from the plastic-encased holding nut.
Threaded Rod
Cone
f. Remove torque nut and washer, leaving anchor and stud in place.
g. For exterior installation on a concrete pad, place a water-tight gasket with
cutouts for conduit and anchors on top of pre-installed pad.
4. If installation includes a base (recommended), proceed as follows:
a. Place base over anchor studs, as shown in the following illustration.
Model MDC-CBAK Anchor Kit
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 2-3
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
b. The front versus rear of the base are dimensionally alike and interchangeable. The top versus bottom are not.
c. Place square washer from the anchor kit over the studs.
d. If using a regular L-shaped concrete anchor, use a suitable nut and tighten all four corner anchors evenly to 38 ft-lb for ½-
3
in. low-carbon steel studs and fasteners or 83 ft-lb for /8-in. hardware.
If using a Telect anchor kit, tighten breakaway torque nut until it shears off plastic-encased holding nut. At shear point, the
holding nut will be properly torqued to 60 ft-lb.
e. Remove and save four bolts and washers at top of base.
Remove 1/2 in. Bolts & Washer Before Setting Cabinet on Base
Either Square Washer From
Anchor Kit or a 1/4-in. Stack of
1/2-in. Fender Washers
Washer & Breakaway Nut
From Anchor Kit
Base
Installing a Base Using Telect Model MDC-CBAK Anchor Kit
5. Use the illustration on the right as a guide in designing a two-point lift
for moving and placing cabinet over anchors.
ALERT
ALERT! DO NOT STAND BENEATH THE CABINET DURING
LIFTING.
6. After moving cabinet into place over anchors, use the Allen-head-style
key to open the doors.
7. Fasten cabinet to base or vault adapter, as shown in the following illus-
tration.
If fastening to a base, use the hardware removed in Step 4d.
8. Torque ½ in., low-carbon steel nuts/bolts to 38 ft-lb.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 2-4
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
Adapter
Vault
Base
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 2-6
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Cabling Without In-Cabinet Splicing
WARNING
!
WARNING! Fiber cables transmit invisible infrared light. To avoid eye damage or blindness, never look direct-
ly into fibers or connectors.
WARNUNG! Faserkabel übertragen unsichtbares Infrarotlicht. Um eine Schädigung der Augen oder Blindheit
zu vermeiden, schauen Sie nicht direkt in die Fasern oder Stecker.
ADVERTENCIA ! Los cables de fibra transmiten luz láser o infrarroja invisible. Para evitar lesiones oculares o
ceguera, nunca mire directamente a las fibras o conectores.
AVERTISSMENT ! Les câbles à fibres transmettent un rayon laser ou une lumière infrarouge invisible. Pour
éviter toute lésion occulaire ou cécité, ne regardez jamais directement dans les fibres ou dans les
connecteurs.
Fiber installation without in-cabinet splicing involves installing connectorized OSP feeder cables to the floor of the cabi-
net’s rear compartment and then terminating those connectors at compartment interface adapters near the top of the cab-
inet. The connectorized distribution cabling is pre-terminated to the patch module assemblies at the factory. These op-
tional patch module assemblies are secured to the cabinet partition. The distribution cables, like the feeder cables, are
secured to the bottom floor of the rear compartment.
After installing all feeder and distribution cables at the cabinet end, the opposite ends are then spliced to OSP cables lo-
cated in a splice enclosure.
FEEDER CABLE INSTALLATION
The cabinet accommodates up to 16 strands of connectorized OSP feeder
cable. Telect supplies two cable clamps that accommodate cables between
/8 in. (9.6 mm) and 1 /5 in. (30.5 mm) in diameter. Each clamp, shown on
the right, uses several layers of gasket or bushing leaves to hold the cable
fast between the two halves of the clamp.
Leaves are provided in an onion
skin roll to accommodate
multifiber cabling from .375 in. to
1.25 in. (9.5 mm to 32 mm) in dia
3
1
OSP cable can be dry or wet, armored or unarmored. To connect to adapters
in the cabinet the cable needs SC/APC connectors.
OSP Cable
To install a feeder cable, proceed as follows:
Bushing Leaves
1. Open rear door.
2. Remove cable entrance dock at bottom of cabinet by removing six sets
of nuts and washers shown in the following illustrations.
The cable entrance dock contains eight slots with slide-out cover plates.
Each slots can accommodate two cable clamps for either feeder or dis-
tribution cable.
3. Slide out cover plate over feeder stub up.
If all feeder cable enters through the stub up closest to the feeder tie-down wall, choose the slot nearest the tie-down wall. If a
second feeder cable is being installed, prefer to locate both in the same slot.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved • Telect Publication 131220 A0
Download from Www.Somanuals.com. All Manuals Search And Download.
Distribution Tie-Down Wall
Feeder Tie-Down Wall
Cable Entrance Dock
Chock Bar
Cover Plates
Preferred Locations of Feeder Cable Clamps
Tie-Down Lance on Feeder Tie-Down Wall
Top View of Cabinet's Rear Floor
4. Use the next illustration to calculate the length of cable(s) required between the splice box (vault or aerial enclosure) and the
feeder adapters near the top of the cabinet’s rear compartment. Use heat-shrink tubing to secure the loose tubing at the end of
the cable(s).
The illustration shows approximate lengths of exposed subunits/buffers to accommodate the 900 µm fiber between the breakout
and the SC/APC connectors. Any breakout length between 15 in. and 50 in. will fit: a short breakout length would place the
breakout near the top of the feeder tie-down wall; conversely longer lengths would be tied down closer to the cable entrance.
Feeder Adapters
(Rear Compartment View)
Subunit/Buffer Between
Breakout and Connector:
16
9
8
1
~15 in. for Connector 16
to ~25 in. for Connector 1
Subunit/Buffer Between
Breakout and Connector:
~40 in. for Connector 16
to ~50 in. for Connector 1
Breakout from Cable to
Subunits/Buffers Near Top of
Rear Compartment
Breakout from Cable to
Subunits/Buffers Near Bottom
of Rear Compartment
OSP Feeder Cable From Splice Enclosure (Dressed Out)
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 3-2
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Feed opposite end of feeder cable(s) through stub-up conduit to splice vault or aerial en-
closure. Before splicing, use cable ties “temporarily“ to hold the cable end(s) in the cabi-
net to convenient lance(s) along the feeder tie-down wall. Tie it down temporarily so that
the SC/APC connectors will reach the feeder adapters at the top of the rear compartment.
6. Wait until all feeder cable is connected and secured in the cabinet before external splic-
ing.
7. Connect SC/APC connectors on all feeder fibers to feeder adapters.
8. Measure diameter of cable(s) and remove and discard that much from the interior of the
cable clamp’s leaf bundle equal to the diameter of the cable(s). The remaining leaves will
be used between the clamp halves and the cable.
9. Nearby the cable entrance, where the cable entrance dock had been, loosely secure the
left bundle(s) and clamp halves to the cable(s), as shown in the illustration at the start of
this procedure.
10. Place cable entrance dock at bottom of cabinet and slip on cable clamps, as shown in the
illustration on the following page.
Solid Core (Discard)
If you have only one feeder cable to install, you must use the other cable clamp to fill out
the slot.
11. Hold down or temporarily fasten dock to cabinet, and then arrange feeder cable(s) and
tubing along the feeder tie-down wall. Use cable ties generously to fasten cable and tub-
ing to the wall.
Bushing Leaf
Don’t use cable ties closer than ~1 ft (~300 mm) from the floor until all feeder and distribu-
tion cables are installed. You’ll need some wiggle room for removing/re-installing the ca-
ble entrance dock.
12. Remove the entrance dock again and securely fasten the cable clamps to the cable.
You will fasten the entrance dock to the cabinet after the distribution cable is installed in the next subsection.
A cabinet with feeder cable installed is shown on the following page.
13. Splice the other end of the feeder cable.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 3-3
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
Feeder Cable (Installed)
PATCH MODULE & DISTRIBUTION CABLE INSTALLATION
Patch Modules come with a 72-strand distribution cable installed at the factory, as shown in the following illustration. The cable is a
dry, unarmored cable containing 6 subunits each with 12, 250 µm fibers.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 3-4
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
Transparent Tubes, Each Containing a
250 µm Fiber With an SC/APC Connector
Subunits
(6, with 12, 250 µm fibers ea)
Patch Module
Heat-Shrink Tube
Cable Clamp
Front
Rear
72-Strand OSP Cable
Fan-Out Blocks
(6, with transition to 12, 900 µm transparent tubes)
Patch Module With Distribution Cable
Telect offers a standard length of cable to fit most applications: 100 ft (30.48 m), measured from a fan-out block attached to the
Patch Module to the stub end. (Custom lengths available on request.) Telect breaks out short lengths of subunits for the shortest
probable distance from the cable clamp to the Patch Module. The subunit breakout can be increased on site. Telect includes the ca-
ble clamp for securing the cable to the bottom of the cabinet and a short length of heat-shrink tubing for covering the breakout.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 3-5
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
The cable clamp, shown on Page 3-1, is the same type used to secure distribution cable. One cable clamps is provided. An addition-
al cable clamp may be required to fill out the two-position entrance slot. (See “Standard Accessories” on Page 7-1.)
The fan-out block allows transition from the 250 µm fiber in subunits to individual connectorized fiber strands in 900 µm transparent
tubes. Telect terminates the connector at adapter ports at the rear of the patch module.
To install a Patch Module with distribution cable, proceed as follows:
1. Open rear door.
2. Remove cable entrance dock at bottom of the cabinet, shown on Page 3-2.
3. Slide-out cover plate over distribution stub up(s).
Patch Modules will be installed from the top position (Patch Module 1) to the bottom (Patch Module 6). Unless otherwise direct-
ed by operating company guidelines, prefer to start with the first distribution stub-up farthest from the patch module rack.
Determine the length of the subunit breakout between the fan-out blocks on the edge of the patch module and the sheathed ca-
ble. The end of the sheathed cable will be either clamped and tied down on the distribution tie-down wall or at the cable clamp
on the cable entrance dock.
NOTE
Telect only breaks out about 7 in. (~175 mm) of subunit. This would be for the shortest breakout from a cable clamp near the
center of the cable entrance dock to Patch Module 6. The longest breakout would be about 64 in (~1600 mm) between a cable
clamp near the left wall (viewed from the front of the cabinet) to Patch Module 1.
All cables entering the cabinet directly below the patch module rack need to be broken out at the cable clamp. The cable is not
flexible enough to manipulate it below the rack and around to the distribution tie-down wall. Conversely, all cables entering the
cabinet directly below the distribution tie down wall should be extended up the tie-down wall and tied down just below a conve-
nient breakout point. (Refer to the illustration on Page 1-4.)
4. Breakout subunits, heat shrink breakout, and then feed the opposite end of the cable into the distribution stub-up conduit.
5. Move the cable clamp down to approximately where the cable will enter the bottom of the cabinet.
NOTE
Before connecting, splicing, storing, or parking distribution pigtails at the home, office, or node, install the Patch Module in the
cabinet, as detailed in the following procedure. Refer to the following illustration.
6. If necessary, provide temporary strain relief while handling and installing Patch Module by, for example, loosely tying down the
cable at a convenient lance along a tie-down wall.
7. Swing out hinged bulkhead from patch module’s anchor plate so that bulkhead fits through rack into front compartment. Then,
secure anchor plate to partition wall using three acorn nuts provided.
8. Secure cable and subunit to distribution cable tie-down wall. Use plenty of cable ties.
Don’t use cable ties closer than about 1 ft (~300 mm) from the floor of the cabinet until all feeder and distribution cables are in-
stalled. You’ll need some wiggle room for re-installing the cable entrance dock.
9. At bottom of cabinet, adjust position of cable clamp in relationship to the cable entrance dock. Don’t secure the entrance dock
until all scheduled distribution cables and Patch Modules are installed.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 3-6
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
Swing Out Hinged Bulkhead
and Pass Through Rack into
Front Compartment
Anchor Plate
Use Three Acorn Nuts
Provided to Secure Patch
Module to Interior Wall of
Cabinet
Temporarily Secure
Breakout End to
Tie-Down Wall
Move Cable Clamp to Bottom
of Cabinet
Installing a Patch Module
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 3-7
Download from Www.Somanuals.com. All Manuals Search And Download.
10. At front of cabinet, secure patch module swing-out door.
Thumbscrew for securing Patch Module Door
11. Repeat Steps 4 through 10 for the next Patch Module and distribution cable.
12. Continue so until all scheduled Patch Modules are installed.
13. Re-insert cable entrance dock: tilt it up as shown in the following illustration, and then slip the feeder and distribution cable
clamps into the slots. Use extra clamps to fill out the slots containing only one cable.
14. Pivot the dock to the floor of the cabinet and re-install the chock bar. Push the chock bar against the cable clamps and secure.
15. Close the rear door.
Finishing Cable Installation
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 3-8
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Cabling With In-Cabinet Splicing
WARNING
!
WARNING! Fiber cables transmit invisible infrared light. To avoid eye damage or blindness, never look directly
into fibers or connectors.
WARNUNG! Faserkabel übertragen unsichtbares Infrarotlicht. Um eine Schädigung der Augen oder Blindheit
zu vermeiden, schauen Sie nicht direkt in die Fasern oder Stecker.
ADVERTENCIA ! Los cables de fibra transmiten luz láser o infrarroja invisible. Para evitar lesiones oculares o
ceguera, nunca mire directamente a las fibras o conectores.
AVERTISSMENT ! Les câbles à fibres transmettent un rayon laser ou une lumière infrarouge invisible. Pour
éviter toute lésion occulaire ou cécité, ne regardez jamais directement dans les fibres ou dans les
connecteurs.
Fiber installation with on-board cabinet splicing involves installing Telect’s optional splice box and distribution patch mod-
ules in the rear compartment of the MDC-CB. The feeder and distribution cables are secured to the floor of the rear com-
partment. The installer routes the fiber breakout to the splice box where it’s spliced to connectorized fiber. In turn, connec-
torized feeder and distribution fiber is routed and then terminated to the compartment interface adapters and distribution
patch modules.
SPLICE BOX INSTALLATION
Install the Model MDC-SPLC Splice Box on the inside of the rear door using the hardware provided, as shown in the following illus-
tration. (See “Accessories” Page 7-3.)
PATCH MODULE INSTALLATION
The Model MDC-P72N Patch Module is installed from and secured to the rear compartment. (See “Accessories” Page 7-3.)
To install, swing out the hinged bulkhead from the patch module’s anchor plate so that the bulkhead fits through rack and into front
compartment. (See the illustration on Page 4-3.) Then, secure anchor plate to partition wall using three acorn nuts provided. In the
front compartment, secure patch module swing-out door.
Install all intended patch modules before installing any cable.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved • Telect Publication 131220 A0
Download from Www.Somanuals.com. All Manuals Search And Download.
Cassette Holders
Splice Box
Installing Splice Box
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 4-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Acorn Nuts (3) Secure Patch
Module to Rear Wall of Partition
Patch Module
Bulkhead Swings on Hinge
to Allow Access to Rear
Connectors and Adapters
From Front Compartment
Installing Model MDC-P72N Patch Module
FEEDER CABLE INSTALLATION
The cabinet accommodates up to 16 strands of OSP feeder cable. Telect sup-
Leaves are provided in an onion
3
skin roll to accommodate
multifiber cabling from .375 in. to
1.25 in. (9.5 mm to 32 mm) in dia
plies two cable clamps that accommodate cables between /8 in. (9.6 mm)
1
and 1 /5 in. (30.5 mm) in diameter. Each clamp, shown on the right, uses sev-
eral layers of gasket or bushing leaves to hold the cable fast between the two
halves of the clamp.
OSP cable can be dry or wet, armored or unarmored. To connect to adapters
in the cabinet the incoming feeder fiber needs to be spliced to fiber strands
with SC/APC connectors.
OSP Cable
Bushing Leaves
To install a feeder cable, proceed as follows:
1. Open rear door.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 4-3
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Remove cable entrance dock at bottom of cabinet by removing six sets of nuts and washers shown in the following illustrations.
The cable entrance dock contains eight slots with slide-out cover plates. Each slots can accommodate two cable clamps for ei-
ther feeder or distribution cable.
3. Slide out cover plate over feeder stub up.
4. Fish feeder cable into cabinet and then remove at least 15 ft (~5 m) of sheathing from the cabinet end.
NOTE
15 ft allows the feeder fiber to reach the furthest splice cassette. Break out more buffer/subunit if you intend to splice anywhere
but at ground level at the open rear door. Add multiples of 8½ ft (~2.5 m) when adding to this length if the splicing is done, for
example, in a vehicle. The multiple represents the perimeter around the splice box for storing the excess length of tubing.
Distribution Tie-Down Wall
Tie-Down Wall for
Incoming Feeder &
Distribution Fiber in
Loose Tubing
Chock Bar
Cover Plates
Cable Entrance Dock
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 4-4
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Carefully remove buffer/subunit tubes from the 15-foot unsheathed end and place fiber
into 3-m radius-control (bend limiting) loose tubing. Use heat-shrink tubing to hold loose
tubing to sheathed end of feeder cable.
Solid Core (Discard)
6. Measure diameter of cables and remove and discard that much from the interior of the ca-
ble clamp’s leaf bundle equal to the diameter of the cables. The remaining leaves will be
used between the clamp halves and the cable.
Bushing Leaf
7. At end of heat-shrink on cable, loosely secure the leaf bundle(s) and clamp
halves to the cable(s), as shown in the illustration at the start of this procedure.
8. Place cable entrance dock at bottom of cabinet and slip on cable clamps, as
shown on the right.
If you have only one feeder cable to install, you must use the other cable clamp to
fill out the slot.
9. Hold down or temporarily fasten dock to cabinet.
10. Remove top cassette holder on splice box, as shown on the right. Save the two
Brackets Will Hold a Pod
of Splice Cassettes to
the Splice Box
nuts
11. Place holder on a splice cart or other convenient work surface.
12. Remove and save two screws near center of holder.
13. Remove transparent cover of cassette.
14. Use the two screws to secure the first (bottom most) splice cassette to the brack-
et, as shown in the next illustration.
15. Add more cassettes, as shown.
Each plastic cassette has molded in pairs of male and female hinge halves. The
female part of the hinge of the top cassette mates with the male part on the cas-
sette below. Two collar screws, supplied with each cassette, secure the hinge.
First Cassette
Adding Cassettes
Installing Cassettes
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 4-5
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE
How many cassettes to place on each holder depends on how many feeder and distribution fiber pairs require splicing. If you in-
tend to accommodate 16 (max.) signals from the CO and up to 432 (max.) from the distribution, you need a total of 19 cas-
settes: one for the feeders and 18 for the distribution. It’s wisest to arrange cassettes more or less evenly among the holders.
It’s also wisest to add all intended cassettes to the stack before running loose tubing and splicing any of the cassettes.
Normally, each cassette holds up to 24 splices. If desired, up to 48 splices will fit each cassette in two layers of 24 — 24 lower
and 24 upper. Two layers makes for a crowd cassette, however, but lessens the number of cassettes overall.
16. After completing a stack of cassettes (a cassette pod), check the length of loose tubing required to reach the cassette. The fol-
lowing illustrations show the shortest and longest required paths for tubing.
The distance between the feeder cable breakout at the cable entrance and the cassette entrance will vary from 5 to 8 ft (~1.5 to
~2.5 m) depending on the starting and ending points in the cabinet and on the door. Check the distance and add in multiples of
8½ ft (~2.5 m), if desired, and then carefully cut off the excess tubing, being mindful of the fiber strands within. DON’T CUT
THROUGH THE FIBER because you will need an additional 3 ft (~1 m) beyond that point for the unprotected strands which will
be in the cassette. So, 3 ft (~1 m) passed the end of the loose tubing, cut away the excess fiber.
Cassette Label
Cassette Pod
NOTES
All feeder fiber is in 3-mm,
radius-control loose tubing between
feeder cable entrance and
connectorized splice.
All distribution fiber is in 3-mm,
radius-control loose tubing between
distribution cable entrance and the
connectorized fan out at the patch
module.
Fiber strands
furcated to 900 µm
loose tubing
Feeder Cable Entrance
Distribution Cable Entrance
Routing Feeder & Distribution Loose Tubing (Overall View)
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 4-6
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 4-7
Download from Www.Somanuals.com. All Manuals Search And Download.
All Fiber From Cable Entrance to the Left
End of Each Cassette Must be in 3-mm
Radius- Control Loose Tubing
Feeder Adapters
Each Fiber From
Right End of Each
Cassette to the
Feeder Adapters
Must Be in 3-mm,
Radius-Control Loose
Tubing
Fiber From Right End of
Each Cassette to Patch
Panels Must Be in 3-mm,
Radius-Control Loose
Tubing
Patch Module
FRONT
REAR
Routing Feeder & Distribution Loose Tubing (Left View of Rear Door)
17. Feed connectorized feeder interface fiber through loose tubing.
18. Secure ends of both feeder tubes at opposite entrances to the cassette, as shown in the following illustration.
19. Route fiber around the perimeter, trim excess, slip on heat-shrink fusion splice sleeve, and splice all fibers from the installed
tubes.
20. Record terminations on designation label included with cassette.
21. Finish all feeder splices before installing and splicing distribution fiber.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 4-8
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
Cable Ties at
Cassette Entrances
1
2
3
4
5
6
1
2
3
4
5
6
7
7
8
8
9
9
10
11
12
10
11
12
13
14
15
16
17
18
13
14
15
16
17
18
19
20
21
22
23
24
19
20
21
22
23
24
To/From
Cable Entrance
To/From
Feeder Interface
Fiber from cable entrance to Splice Positions 1
through 12 will be at the right end of the splice.
Fiber from cable entrance to Splice Positions 13
through 24 will be at the left end of the splice.
Fiber from feeder interface to Splice Positions 1
through 12 will be at the left end of the splice.
Fiber from cable entrance to Splice Positions 13
through 24 will be at the right end of the splice.
Routing Fiber in a Cassette
22. Apply the designation label to the cassette cover and connect ends of fiber into adapters
on the feeder interface shown on the right.
23. Continue with “Distribution Cable Installation” in the next section before installing the pod
on the door and before securing tubing to the cabinet and door. Do not mix feeder and
distribution splices in the same cassette.
DISTRIBUTION CABLE INSTALLATION
The cabinet accommodates up to 432 strands of OSP distribution cable.
Telect does not include cable clamps for the distribution cable. The cable clamps are the same
type used for the feeder cables. See “Accessories” on Page 7-2.
Like the feeder cable, OSP distribution cable can be dry or wet, armored or unarmored. To connect to adapters in the patch module,
the incoming distribution fiber needs to be spliced to fiber strands with SC/APC connectors.
The breakout, splicing, and routing of distribution is similar to that of the feeder. In brief,
1. As before, remove at least 15 ft (~2.5 m) of sheathing from the distribution cable entering the cabinet. More, if desired, in 8½ ft
(~2.5 m) increments. Also remove the buffer/subunit tube covering the fiber and slip on 3-mm, radius control loose tubing.
2. Heat shrink tubing to cable at entrance dock and then attach a cable clamp
3. Check the length of loose tubing required for the run between the cassette and the fan-out block on the patch module.
The distance will vary from 6¾ to 9¾ ft (~2 to 3 m) depending on the starting point on the door and the location of the patch
module. Check the distance and add in multiples of 8½ ft (~2.5 m), if desired, to determine tubing length. For the fiber, you will
need this length plus an additional 4 ft (~1.25 m) beyond that point for the unprotected strands which will be in the cassette and
for the fiber from the entrance of the fan-out block to the adapter on the patch module.
4. For each loose tube of 12 fibers, you will need a fan-out block to adapt the fiber in one loose tube to individual fibers in a 900 µm
loose tubes.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 4-9
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
To use the fan-out block, proceed as follows:
Loose Tubing
Transparent Tubes
a. The furcation block has about 1.5 m (~5 ft) of transparent tubing for 900 µm fi-
bers. Cut the transparent tubing back to 11½ in.(~300 mm).
b. Slip the fibers through the furcation block and transparent tubes and move the
ends of the transparent tubes up to the SC/APC connectors.
c. Next, slip on the heat-shrink tube supplied with the fan-out kit
d. Place the furcation block onto the bottom cover.
e. Snap on the top cover.
f. Slide up the heat-shrink tube against the block and heat shrink.
Furcation Block
Bottom Cover
Heat-Shrink Tube
5. Secure ends of both distribution tubes at opposite entrances to the cassette, route
fiber throughout cassette (Page 4-9), trim excess, slip on splice sleeve, and splice.
6. Record terminations on designation label included with cassette.
7. Finish all splices in a cassette before moving to the next.
8. Continue with the remainder of the fibers from the distribution cable — splicing them to connectorized fibers — before moving to
the next cable.
After every 72 fibers (6 fan-out blocks), connect ends of fiber into adapters on the patch module, shown in the following illustra-
tion. Use the bracket provided on the patch module to secure the fan-out blocks to the patch module chassis.
6 Fan-Out Blocks
Per Patch Module
9. Complete all cassettes in a pod before mounting the pod to the rear door and before routing the loose tubing.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 4-10
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUTING FEEDER & DISTRIBUTION LOOSE TUBING
When completed and before moving to the next cassette pod,
1. Install completed cassette pod on the rear door.
2. Route all loose tubing as planned and use cable ties liberally to secure tubing to lances on door and in cabinet.
3. After all feeder and distribution cabling and loose tubing has been installed, spliced, and routed, re-insert cable entrance dock,
tilt it up as shown in the following illustration, and then slip the feeder and distribution cable clamps into the slots. Use extra
clamps to fill out the slots containing only one cable.
4. Pivot the dock to the floor of the cabinet and re-install the chock bar. Push the chock bar against the cable clamps.
5. Secure the chock bar and close the rear door.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 4-11
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 4-12
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Cross Connections
WARNING
!
WARNING! Fiber cables transmit laser or invisible infrared light. To avoid eye damage or blindness, never look
directly into fibers or connections.
WARNUNG! Faserkabel übertragen unsichtbares Infrarotlicht. Um eine Schädigung der Augen oder Blindheit
zu vermeiden, schauen Sie nicht direkt in die Fasern oder Stecker.
ADVERTENCIA ! Los cables de fibra transmiten luz láser o infrarroja invisible. Para evitar lesiones oculares o
ceguera, nunca mire directamente a las fibras o conectores.
AVERTISSMENT ! Les câbles à fibres transmettent un rayon laser ou une lumière infrarouge invisible. Pour
éviter toute lésion occulaire ou cécité, ne regardez jamais directement dans les fibres ou dans les
connecteurs.
ALERT
!
ALERT! This product must be installed and maintained by qualified technicians.
After installing all feeder and distribution cabling in the rear compartment, close the rear compartment. All subscriber
changes are done in the front compartment. First, however, the high-intensity feeder signals needs to be split before cross
connecting to the distribution.
Telect Splitter Modules are installed, interconnected to the incoming feeder fiber, and cross connected to distribution fiber in the front
compartment. After installing OSP cable, the rear compartment need not be re-opened.
Telect manufactures four Splitter Module configurations for this cabinet: 1 x 4, 1 x 8, 1 x 16, and 1 x 32.
To install a Splitter Module, proceed as follows:
1. Start at Splitter Position 18 on the right and insert module in splitter bulkhead near
bottom of front compartment.
2. As shown in the illustration on the right, push in the two plunger-style latches to se-
cure the module.
The splitter module has one blue 2-mm jumper for the feed-in and 4, 8, 16, or 32
yellow 2-mm jumpers for the distribution. All splitter jumpers are 2.1 m in length.
3. Route the blue jumper to the first feeder adapter on the left at the top of the front
compartment, as shown in the illustration on the right.
Installing Splitter Module
Going from right most splitter module to left most feeder adapter guarantees that
the blue jumpers from all splitter modules will neatly fit the same pathway around
the routing arcs and spools in the right half of the compartment. Prefer to route
the blue jumpers as shown in the following illustration, that is, around the bottom,
right most spool, up to the nearest arc, down around the bottom most spool to the
left of the other, and on up to the feeder bulkhead.
Connecting to Feeder
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved • Telect Publication 131220 A0
Download from Www.Somanuals.com. All Manuals Search And Download.
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16
Feeders
Unassigned
Distribution
(Parking)
1
2
3
4
5
6
7
8
9
10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 48
61 62 63 64 65 66 67 68 69 70 71 72
25 26 27 28 29 30 31 32 33 34 35 36
49 50 51 52 53 54 55 56 57 58 59 60
1
2
3
4
5
6
7
8
9
10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 48
61 62 63 64 65 66 67 68 69 70 71 72
25 26 27 28 29 30 31 32 33 34 35 36
49 50 51 52 53 54 55 56 57 58 59 60
1
2
3
4
5
6
7
8
9
10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 48
61 62 63 64 65 66 67 68 69 70 71 72
Assigned
25 26 27 28 29 30 31 32 33 34 35 36
Distribution
to Subscriber
49 50 51 52 53 54 55 56 57 58 59 60
1
2
3
4
5
6
7
8
9
10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 48
61 62 63 64 65 66 67 68 69 70 71 72
25 26 27 28 29 30 31 32 33 34 35 36
49 50 51 52 53 54 55 56 57 58 59 60
1
2
3
4
5
6
7
8
9
10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 48
61 62 63 64 65 66 67 68 69 70 71 72
25 26 27 28 29 30 31 32 33 34 35 36
49 50 51 52 53 54 55 56 57 58 59 60
1
2
3
4
5
6
7
8
9
10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
25 26 27 28 29 30 31 32 33 34 35 36
37 38 39 40 41 42 43 44 45 46 47 48
49 50 51 52 53 54 55 56 57 58 59 60
61 62 63 64 65 66 67 68 69 70 71 72
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18
Splitter
Bulkhead
Feeder Cable to Splitter
Assigned & Unassigned Distribution Cable
Distribution Routing
4. Now route the yellow jumpers for assigned and unassigned distribution:
•
For assigned distribution (connecting to a subscriber), route the cables to the right, around the right most spool at the bot-
tom, and then up to and around one of the four arcs directly above, as shown in the illustration. Pick one of the arcs above
the intended patch. (Always reserve the top most arc and spool for as yet unassigned cable and for dropped subscribers.)
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 5-2
Download from Www.Somanuals.com. All Manuals Search And Download.
•
For unassigned distribution or for disconnected subscribers, route the cable up and around one of the top two arcs and
spools and then plug the connector (with dust cover attached) into one of the rubber holders between the feeders and the
Patch Modules, as shown in the illustration.
Parking for
Unassigned
Distribution
Parking Unassigned Distribution Jumpers
5. Record splitter and subscriber assignments on the erasable label applied to the inside of the front door.
A replica of the designation label is shown in the following illustration.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 5-3
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
PANEL
1
FIBERS
1-72
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
PANEL
2
FIBERS
73-144
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
PANEL
3
FIBERS
145-216
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
PANEL
6
FIBERS
361-432
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
PANEL
5
FIBERS
289-360
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
PANEL
4
FIBERS
217-288
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
FIBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
Designation Label
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 5-4
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Service
WARNING
!
WARNING! Fiber cables transmit laser or invisible infrared light. To avoid eye damage or blindness, never look
directly into fibers or connections.
WARNUNG! Faserkabel übertragen unsichtbares Infrarotlicht. Um eine Schädigung der Augen oder Blindheit
zu vermeiden, schauen Sie nicht direkt in die Fasern oder Stecker.
ADVERTENCIA ! Los cables de fibra transmiten luz láser o infrarroja invisible. Para evitar lesiones oculares o
ceguera, nunca mire directamente a las fibras o conectores.
AVERTISSMENT ! Les câbles à fibres transmettent un rayon laser ou une lumière infrarouge invisible. Pour
éviter toute lésion occulaire ou cécité, ne regardez jamais directement dans les fibres ou dans les
connecteurs.
ALERT
!
ALERT! This product must be installed and maintained by qualified technicians.
TECHNICAL SUPPORT
By e-mail: getinfo@telect.com
By phone: 888-821-4856 or 509-921-6161
IN-WARRANTY SERVICE
Contact your Telect equipment distributor, or call a Telect Customer Service Representative:
1-800-551-4567
1-509-926-6000
Telect will repair or replace defective products within the limits of the warranty. See “Repacking for Shipment” in this section.
NOTE
Call a Customer Service Representative for a Return Material Authorization (RMA) before returning any equipment.
OUT-OF-WARRANTY SERVICE
The procedure for out-of-warranty service is the same as for in-warranty service, except that Telect charges a processing fee, and
you must submit a Purchase Order along with a Return Material Authorization (RMA) before returning equipment. Call a Customer
Service Representative for help getting these forms.
The processing fee guarantees a repair estimate and is credited against actual material and labor costs.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved • Telect Publication 131220 A0
Download from Www.Somanuals.com. All Manuals Search And Download.
REPACKING FOR SHIPMENT
1. Tag the equipment showing owner’s name, address, and telephone number, together with a detailed description of the problem.
2. Use the original shipping container if possible. If you do not have it, package the equipment in a way to prevent shipping dam-
age. Include the RMA inside the container and legibly print the RMA number on the outside of the package, near the shipping
address.
3. Insure the package.
NOTE
Telect is not liable for shipping damage.
CLEANING PATCH MODULE CONNECTORS & ADAPTERS
The Patch Module adapters are mounted to a hinged bulkhead to allow access to both connectors on opposite sides of the adapters
without having to open the rear cabinet door.
The performance of Patch Module optical fiber connectors or adapters depends, to a large degree, on the cleanliness of the connec-
1
tors and adapters at the time of connection. To thoroughly clean connectors and adapters , proceed as follows:
2
1. If both connectors have been removed from the adapter, blow compressed gas through the adapter.
2. Wipe completely around the ferrule of the connector twice with a lint-free wiping material that has been moistened with reagent-
grade ethyl alcohol, nominal USP > 99%.
3. Repeat Step 2 with a dry wipe.
4. Blow compressed gas across the end of the ferrule. This is the final step before inserting the connector. Do not wipe the ferrule
or allow it to touch anything after completion of this step.
5. Insert connector into adapter.
6. Repeat Steps 2 through 5 for the other connector.
1. Procedure is adapted from GR-326-CORE, Issue 3, Sept 1999, Section 4.3.
2. Compressed air or canned compressed gas that is clean, dry, and oil-free.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 6-2
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Accessories
MDC-CB accessories and replacement items are listed in the following table. Contact Telect for price and availability.
STANDARD ACCESSORIES
Item
Model
Illustration
72-Channel Patch Module Con-
nected to 100 Ft of OSP Ca-
bling*
MDC-P72N-F100D
(dry, flexible, unarmored cable
with 72, 250 µm strands fully
protected in subunits, along
with fan-out blocks, one cable
clamp and heat-shrink tubing)
* Custom cable lengths available.
Splitter Modules
1 x 4
MDC-SP-N04S
MDC-SP-N08S
MDC-SP-N16S
MDC-SP-N32S
1 x 8
1 x 16
1 x 32
Cabinet Base, 12 in.
MDC-R12
Concrete Anchor Kit, 6 in.,
Seismic
MDC-CBAK
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved • Telect Publication 131220 A0
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
Model
Illustration
Cable Entrance Clamp Kit
MDC-CLMP
(includes 4 clamps)
Ground Bonding Kit for Ar-
KIT-BOND
1
mored OSP Cable
1. Kit contains hardware for OSP armored cable from 0.5 in. (12.7 mm) to 1.6 in. (40.64). Kit also contains an 11 in. (~280
mm), 6 AWG ground wire assembly with single-hole lugs for #10 studs on both ends.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 7-2
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
IN-CABINET SPLICING ACCESSORIES
Item
Model
MDC-P72N
Illustration
72-Channel Patch Module
Only*
(with dust covers in both ends
of SC/APC adapters; without
cabling, clamps, or fan-out
blocks
Splice Box* for In-Cabinet
MDC-SPLC
1
Splicing
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 7-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
Splice Cassette
Model
Illustration
MDC-HS24
(includes cassette label)
Splice Sleeves, Pkg of 12
101521-12
1. Installs on inside of rear door. Installation and routing of cable is different with in-cabinet splicing.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Page 7-4
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
Telect assumes no liability for the application or use of these products. Neither does Telect convey any license under its patent rights or the patent
rights of others. This document and the products described herein are subject to change without notice.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2006 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Copyright © 2002 Telect, Inc., All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Technicolor Thomson Universal Remote VPH6920F User Manual
Thule Boating Equipment 579 User Manual
Toastmaster Oven 310 310CAN User Manual
Traulsen Freezer AIF132HUT FHS User Manual
TRENDnet Wireless Office Headset 113004 User Manual
Trion Air Cleaner Air Boss One Man Portable User Manual
Turbo Chef Technologies Oven HHB 8028 User Manual
Vidikron Flat Panel Television VP 4200 User Manual
Viking Appliance Trim Kit F20713 User Manual
VocoPro DVD Player DVX 680K User Manual