BF-562GB解除- 裏から3 ページ1
For Home Use
Body Fat Monitor/Scale
BF-562
Instruction Manual
Please note!
Improper use of this product could cause serious injury or damage to the
product or other property. Please read this manual carefully before use and
keep aside for future reference.
( )
TBF5627811 3
Download from Www.Somanuals.com. All Manuals Search And Download.
BF-562海外GB+D面付解除 ページ7
Parts/Accessories
Preparation
LCD Display
Weight Only / OFF Button
Using the Bracket for Wall Installation
The display box can be used with the attached bracket for wall installation.
The display box can also be used horizontally(eg on tables).
SET Button
UP Button
Personal Memory Key (5 users)
*Please note: If you measure yourself while holding the display box in your hand, this weight(about 500 g) will be added
to your body weight.
Time / DOWN
Button
GRAPH Button
ቢDeciding on the position of the bracket for wall installation
Ensure the bracket is no higher than 1.7 m from the floor.
Do not use the equipment if the connection cable is tightly stretched or
part of the platform is unsupported, as this may cause malfunction.
Battery Box Cover
(on the Bottom)
Display Box
Scale Platform
Underside
ባAttaching the bracket for wall installation
Firmly screw the bracket to the wall by inserting the screws (x 2)
through the holes in the bracket using a cross head screwdriver.
Connection Cable
Scale Platform
ቤAttaching the display box
Hang the battery box cover on the back of the display box, insert the
hooks of the large bracket into the holes on the bottom to attach the
display box.
Front
Electrode
Heel Electrode
Holes for Carpet Feet (Four in Total)
aCheck the Accessories!
Remarks
ȞInstruction Manual (This Manual) ȞDry Cell Batteries (AA x 4)
ȞCarpet Feet (x 4)
(R6P)
ȞOperating Chart
ȞWarranty
aAlways use the attached screws to attach the bracket for wall
installation
If you attach the bracket with double-sided sticking tape, for example, it may fall down.
ȞBracket for Wall Installation
aEnsure that the display box is firmly hooked on the bracket for wall
installation
If the display box is not hung on both hooks, it may fall down or become unstable.
ȞScrew (x 2)
Remove when you need to use them.
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
BF-562海外GB+D面付解除 ページ9
Preparation
Loading the batteries
When you put dry cell batteries in
for the first time after purchasing
the equipment, the product will ask
you to check the calender.
ቢLocate the battery compartment behind the display box.
Installing the Scale Platform
ባopen the battery box cover.
ቤput in the AA R6P dry
cell batteries. (Included)
a
a
Use this equipment on a hard flat surface.
U
1
If using the unit on soft carpets, attach the carpet feet.
©
With the carpet feet you can
perform measurement even on
carpets up to 20 mm thick.
a
The life of the dry cell batteries is about 1 year if the
product is used once a day. The life of the batteries
included may be shorter than stated above.
Support
(Attached)
Support
Hole
Wrong way to
attach foot
Correct way
to attach foot
Caution
a
a
Do not use carpet feet except on carpets.
This could make the product unstable.
Changing the Dry Cell Batteries
a
Even if the batteries are removed, memorised personal data (birthdays, gender, heights and measurement figures)
will not be deleted.
Do not damage the connection parts or connection
cable.
a
When changing dry cell batteries or operating the equipment, if the LCD behaves oddly or the switch does not work,
please remove the batteries, wait until the LCD clears (for about five minutes) and put the batteries back in again.
If you use force to bend, pull, twist or step on them, this may cause
failure or malfunction.
©
If the dry cell batteries are exhausted,
measurement.)
starts to flash on the display. (You cannot operate the equipment or perform
Lo
a
Do not carry the equipment by holding it only by
Please change all four batteries immediately to ensure continued accuracy.
* While is flashing, even if you remove the dry cell batteries, the set date and time are
maintained (for about five minutes.)
Please change the dry cell batteries as quickly as possible.
* Never use alkaline dry cell batteries together with manganese dry cell batteries, as this may cause
malfunction.
Lo
the connection cable.
This may cause failure, breakage or malfunction, and there is a risk of
damage if you drop the equipment.
Display
Connect the Display Box to the Scale
©
After changing the dry cell batteries, the following displays appear. Please follow each instruction and operate the
equipment accordingly.
Platform
2
Be sure to hold the plug at the end of the connection
cable and insert it into the display box. (Insert it straight
into the box so that the triangle signs on both sides
meet.)
©Press the
and check the date and time in the
Time/DOWN
When
flashes for
Lo
calendar.
•
a few seconds and then
disappears.
•If the date or time is wrong, please correct it. (See How to change
the calendar on page 21.)
Caution
•When
is displayed, please set the calendar.
When nothing is displayed.
•
•
Be sure to insert and pull out the connection cable by
(See Calendar Setting on page 10.)
holding the plug at the end of the connection cable.
Otherwise this may damage the product.
©
Please set the calendar. (See the Calendar Setting on page 10.)
When
is displayed.
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.
BF-562海外GB+D面付解除 ページ11
Calendar Setting
Before measuring
* The blue parts in the illustrations of the display signify the flashing parts.
Set the calendar
Confirm that the dry cell
batteries are installed.
Set the “Day”.
Set the “Time”.
This equipment has a function for memorizing measurement
results and displaying graphs.
e. g. In the case of 10th
e. g. In the case of 2 p.m.
1 3 5
In order to efficiently use this function please set the
calendar correctly.
Press
Press
Following the instructions on
page 11, please place the
U
batteries correctly.
or
(The LCD will appear as here
(right), if the calender is not set.)
or
and set the “Day”.
U
to make the clock flash.
press
and finalize the
Press
U
U
Set the “Month”.
setting. (The display changes to
the time setting screen.)
e.g.: In the case of August
or
Display
2
Press
or
U
and set the “Time”.
* A.M. is displayed as “A” and
P.M. is displayed as “P.”
U
U
to make the calendar flash.
Set the “Year”.
press
and finalize the
e. g. In the case of the 1999.
U
4
Press
setting. (The display changes to
the time setting screen.)
Press
or
U
U
or
to make the “Month” flash.
and set the “Year”.
Set the “Minute”.
e. g. In the case of 35 minutes
Press
and finalize the
6
7
Press
or
Press
or
U
SET Button
UP Button
set the “Month” and press
setting. (The display changes to
the time setting screen.)
and set the
“Minute”. Press and
to finalize the “Month”.
Time/DOWN Button
GRAPH Button
U
(The next item to be set will flash.)
U
finalize the setting.
Automatic Power Off Function
Points to Note
Remarks
Finalize the calendar.
a
a
a
In order to save power the unit will automatically
switch off after use. (The display disappears.)
The automatic power off function also works in the
following case.
If you have made a mistake during setting,
ePlease press the
While “PRESS SET” is
flashing on the screen,
GRAPH
button.
a
Do not continuously press
If you keep the button depressed, the data may be set
incorrectly.
button.
SET
This operation takes you back to the month setting,
then correct the setting.
When you want to change the calendar setting,
ePlease refer to the “How to Change the Calendar”
on page 21.
press
again to finalize
©
When the button operations are stopped.
Although it depends on the operation concerned, the power
will be switched off after about 20 to 30 seconds.
UU
the calendar.
(The finalized setting is
displayed and then disappears.)
The calendar setting is finished.
10
11
Download from Www.Somanuals.com. All Manuals Search And Download.
BF-562海外GB+D面付解除 ページ13
Registration of Personal Data
Before measuring
Memorising personal data.
Selecting the measure of weight.
Register the date of birth.
Register the gender/body type
e.g.: In the case of a female athlete
Decide on your
number and memorise the data
Personal
1. Press
button and the
button at the same
e.g.: If the date of birth is December 18, 1962
(ie Male Athlete, Male Standard, Female Athlete, Female Standard)
(birthday, gender and height).
2 3
time.
Without registration, you cannot measure yourself or record
Press
Press
or
the results.
Display
or
and set
and
select your “Gender”.
your “Month of Birth”.
2. Press
or
button to select Kg, st.lb, lb,
Press
and finalize
U
then press the
button.
the month.
Press
Press
and finalize
The selected measure will flash rapidly, then turn off
automatically.
U
SET Button
your gender.
(The next setting item starts to
flash.)
UP Button
or
and set
Time/DOWN Button
GRAPH Button
your “Day of Birth”.
Press and finalize
U
the day.
Register the height.
e.g.: If your height is 165 cm
Press
* The blue parts in the illustrations of the display signify the flashing parts.
4
5
Press
or
or
and set
Decide on your personal
your “Year of Birth”.
and set
number.
your “Height”.
1
e.g.: To use
Memory Key “3”.
Personal
While nothing is displayed
Remarks
Press
and finalize
a
You can register birthdays for individuals aged from
one to 90 years.
on the display, press
U
U
Finish the registration.
Press
For an individual who is 91 years or older, register the
birthday so that he / she is 90 years old.
the year.
(The display shows as right and
the
number blinks.)
Personal
and finalize
UU
the memorisation
Points to Note
a
When you find you made a mistake during setting.
Press
or
(The memorisation.)
ePlease press the
button. Since this
GRAPH
operation takes you back to the registration of your
birthday, please start the registration again.
to select your
Memory Key and finalise.
Personal
(After the memorised data
flashes, the display disappears.)
a
a
In order to register with another
eAfter the display disappears, please start over again.
number,
Personal
the number by pressing
U
The memorisation is
finished.
When you want to change memorised data for
another individual’s data.
(The next setting item starts to flash.)
ePlease refer to “Correction and Alteration of
Personal Data” on page 22.
12
13
Download from Www.Somanuals.com. All Manuals Search And Download.
BF-562海外GB+D面付解除 ページ15
(For Pre-set data)
How to Measure
Ȟ Have you memorised your personal details?
Press your “Personal”
Start measurement.
Remarks
ቢ Measurement is finished.
“Body weight” and the “Body
fat percentage” will be
displayed for about
After 0.0 kg is displayed,
Memory Key.
1 2
(A short beep will sound.)
be sure to stand on the
Measure barefoot with clean, dry feet.
weighing platform barefoot
so that your heels touch the
center of the electrodes.
©Stand up with your knees straight.
©Ensure the insides of your thighs are not touching.
©Place your heels correctly on the electrodes.
3 seconds.
(Two short beeps will sound.)
When your data is
memorised with “3”.
Points to Note
aIf the display box and the scale platform are not
firmly connected.
"ERROR" will be displayed and you cannot measure
The measurement will be
automatically recorded.
* If “NOT RECORDED” is
displayed, please measure
yourself again within one
minute. (For details, please
refer to page 18.)
ቢ First, the calendar is
displayed.
e
Step on the scale platform
berefoot.
yourself.
aIf the soles of your feet are not clean or you are not
standing on the scale platform correctly,
“-----" will be displayed and you may not be able to
measure yourself.
aIf the body fat percentage exceeds the range of
ቢ Your body weight will be
displayed.
e
(A short beep will sound.)
The BMI figure is displayed.
measurement,
Note: When measured in the
athlete-mode, the BMI figure
will not be displayed.
ባ Next, your date of
birth, height, gender
and the “Personal”
Memory Key are
displayed.
“----" will be displayed and you cannot measure
e
yourself.
a
0.0
If you step on the scale platform before
displayed,
kg is
ERROR , -1.1
-OL
,
e
Displays such as
or
may
ባ
Then “ooooo” will appear in
succession.
appear or the power will be switched off during
measurement.
Until the “Body fat
Graphs are displayed and
then the unit will switch
off.
percentage” is displayed on
the digital display, move as
little as possible and stand
straight.
ቤ
The display changes to
0.0
kg.
The measurement range of the body fat percentage is
between 1.0% and 75.0%.
If the details are not stored in the memory...
ePlease refer to “Guest Mode:Measuring without pre-
set data” on page 20.
Automatic Power Off Function
a
In order to save power, the power will be
automatically switched off after use. (The display
disappears.) This function also works in the
following cases.
Display
Personal
Memory key
(for five individuals)
©
When the button operations are stopped.
Although it depends on the operation concerned, the
power will be switched off after about 20 to 30 seconds
Front
electrode
©
When about 30 seconds have passed without
you stepping on the scale platform after
“0.0” kg is displayed.
©
©
When you stepped off the scale platform
during the measurement.
When about 30 seconds have passed since
the graph was displayed.
Heel
electrode
14
15
Download from Www.Somanuals.com. All Manuals Search And Download.
BF-562GB解除- 裏から3ページ3
Body Fat Monitor/Scale
CONTENTS
Thank you for purchasing this Body Fat Monitor/Scale. This product determines your body fat percentage by measuring
bioelectrical impedance (i.e. the body's electrical resistance), allowing you to monitor your health at home and help keep your
body fat level in check to avoid health problems associated with obesity.
Read this first!
Checking Body Fat is a step towards a healthier life.
This scale can be used safely and conforms with Medical Equipment Directive IEC-601-1.
•Notes on safety............................................................................................................................
•Notes on correct use.............................................................................................................
•Parts/Accessories........................................................................................................................
4
5
6
What does your body fat percentage indicate?
•The body fat percentage indicates the proportion of fat in a person’s body.
High levels of body fat can lead to heart disease, diabetes, high blood pressure and some forms of cancer. It is
important to monitor regularly to keep body fat levels in check.
Product benefits
•Measures both weight and body fat percentage and
evaluates BMI.
How the Body Fat Monitor/Scale measures your body fat percentage
•This product was researched and developed using bioelectrical impedance analysis (BIA), which is a method of
determining body fat percentage by measuring the body’s electrical resistance.
•Fat in the body conducts hardly any electricity, whereas the water contained in muscles is a good conductor of
electricity. Measuring electrical resistance thus offers a way of determining the proportion of fat and other tissue in
the body.
st
•
Measures and displays weight up to a max of 136kg/21 6lbs
in graduations of 100g/0.2lbs. Measures body fat to the
nearest 0.1%
Notes on use
•Memorises details for up to 5 regular users. Displays graph
showing present weight/body fat % against past progress.
•It displays graphs in which it is easy to observe changes
(body weight and body fat percentage).
•Preparation.........................................................................................................................................
•Loading the batteries...........................................................................................................
(Calendar Setting)...................................................................
7
9
10
12
14
How best to determine your body fat percentage
Variation in bioelectrical impedance (i.e. the body’s electrical resistance) is one factor that must be
taken into account when determining body fat levels by BIA.
•Before measuring
(Registration of Personal Data)...................................
(For Pre-set date)....................................................................
•Readings will vary depending on your physical condition (e.g. if you are ill, have been overeating or
overdrinking, have been sweating excessively, or during menstruation) on the day you measure
your body fat level. Changes during the day also have an impact. (Normal bioelectrical impedance
increases during sleep and falls during activity). see graph below.
•Try to measure your body fat level at around the same time each day and when in the same
condition.
•How to Measure
•When “NOT RECORDED” is Displayed.........................................................16
•How to Read the display.............................................................................................17
•Graph Display Function.................................................................................................18
•To Measure Body Weight alone.........................................................................19
•Guest Mode: Measuring without pre-set data.............................20
•How to Change the Calender................................................................................21
•Alteration of Personal Data.....................................................................................22
Ideal conditions for use
Time
: Early evening, before the evening meal.
Conditions
: Clean body and soles of feet well. Wear as little clothing as possible (preferably just
underwear).
•Shows up to 5 years' worth of past resuits.
•Features weight-only function for use as a conventional
scale. Suitable for use by adults and children over the age
of 7 years old.
Monitor your
progress
: Provides a long-term picture of changes in weight and body fat percentage.
Body Fat Ranges for Standard Adults
Read when necessary!
aThis product features the "Athlete Mode".
This mode is specially designed for those adults performing
large amounts of intense aerobic exercise, due to the
changes that such individuals bodies undergo.
*The Athlete Mode is suitable for:
•People performing more than 10 hours of intense aerobic
exercise a week, who also have a resting pulse of below
60 beats per minute.
Age 20-39
Age 40-59
11%-22%
23%-34%
Age 60+
13%-25%
24%-36%
•Troubleshooting.......................................................................................................................24
•In the case of problems.................................................................................................25
•Specifications..............................................................................................................................26
Men
8%-20%
Women
21%-33%
Source:Based on WHO BMI Guidelines. As reported by Gallagher et al at NY Obesity Research
Centre. To determine the percentage of body fat appropriate for your body, please consult a
doctor or trained medical professional.
The Body Fat Monitor/Scale also measures your BMI
BMI stands for "Body Mass Index" and indicates body size. BMI is calculated by dividing weight (in kg), by the
square of your height (in m). Eg weight/height × height height (kg/m × m).
•People who are performing slightly less than this figure,
but who have trained regularly throughout their lives at
such an intense level.
BMI is often used as a measure of obesity, according to the table below. However, because BMI is a measure of
weight and height alone, it does not distinguish between muscle and fat tissue. Tanita therefore recommends that
you use both BMI and body fat percentage to check the state of your health.
*The Athlete Mode is not suitable for the following:
•Professional athletes or body buildres.
Such people should use the Body Fat Monitor/Scale to
monitor their change in their body fat only, not as an
absolute guide.
Underweight
Less than 18.5
Normal Weight
18.5-24.9
Overweight
25-29.9
Obese
Over 30
2
3
Download from Www.Somanuals.com. All Manuals Search And Download.
BF-562海外GB+D面付解除 ページ17
When "NOT RECORDED" Is Displayed
How to read the display
While recording the results of your measurement,
Personal
Memory Key (for five individuals)
sometimes "NOT RECORDED" is displayed and you cannot
record the data.
<Displaying Graphs after Measurement>
Display
SET Button
UP Button
Time/DOWN Button
Personal
Ensure that you use your own
Memory Key.
<Displaying Past Graphs (More than a year ago)>
1 3
ቢ When "NOT RECORDED" is displayed for the first time, ብ The measurement is recorded.
Personal
press your
Memory Key again within one
minute.
ባ Measure yourself.
4
2
ቦ The BMI is displayed followed by the graphs.
Points to Note
ቤ When "NOT RECORDED" is displayed for the second
aThe upper and lower limits for body weight and the body
fat percentage change according to the recorded
measurements.
aIf you press the SET button, the figure at the cursor's
position will be displayed. (See "Graph Display Function"
on page 18.)
time, press
ቧ and the power is switched off.
16
17
Download from Www.Somanuals.com. All Manuals Search And Download.
BF-562海外GB+D面付解除 ページ19
Graph Display Function
To Measure Body weight alone
The equipment can record results for a maximum of 5 years, and display them as graphs. (This function is not available for individuals
whth no pre-set data, or who only measure their body weight).
Points to Note
Press the "WEIGHT only/OFF"
Button.(A short beep will sound.)
Displaying graphs.
To display past measurements
aYou cannot record the measurement results.
e. g. When you want to display the graph registered
Move the cursor from the current to the past by
1
T
o record the measurement results after
e
against the
Memory Key 3.
Personal
memorising personal data, please follow the
instructions specified in "How to Measure (For
Registered Individuals)" on page 16.
1 2
pressing
After
0.0
is displayed
88888
kg will be displayed.
With the display
clear.
aIf body weight exceeds the measurement
(By pressing
you
press
range.
can move
"OL OVER LOAD" or "OVERLOAD" will be
kg
%
e
the cursor from the
past to the current
measurement.)
U
displayed and you cannot measure yourself.
a If you step on the scale platform before
"0.0" kg is displayed,
"SELECT YOUR NO."
will be displayed
and the
Personal
By pressing the
"Time/DOWN" button
ERROR -1.1
-OL
, will
eDisplays such as
,
or
Memory Key will
blink.
appear or the power will be switched off
during measurement.
you can move the cursor.
Start measurement.
Press your
Step on the weighing
platform carefully
after kg is
Memory
Personal
Key.
* Day Area:
-1 ~ -6 is displayed.
2
0.0
displayed.
(In this case, press 3.)
Week Area:
-1 ~ -12 is displayed.
Month Area:
Year and month
(e.g. 99-1) are displayed.
Button
WEIGHT only/OFF
Display
Remarks
a
In the following cases the measurement may be lost.
(If necessary record important measurements in a notebook).
©When the equipment has been used continuously in
the wrong way.
Your "Body Weight" will
be displayed.
Displaying Measurements.
Press "SET"
(While pressed, the
©When the equipment is subjected to static electricity
or electrical noise.
©When malfunctions related to the recording
mechanism occur.
3
figure at the cursor
position is displayed.)
U
Step off the scale
platform.
a
If "NO DATA" is displayed,
kg will be displayed
0.0
Measurements were
not recorded at the
time to which the
cursor is pointing.
(This is not a malfunction.)
e
again and the power will be
switched off.
* Please note the manufacturer accepts no responsibility for damage caused by
loss and changes to the recorded data.
* Please note the manufacturer accepts no responsibility for any damage, lost
profits or any claims by a third party arising from the use of this equipment.
aThe displayed figures are weekly and monthly
averages.
Display
aWhen you want to end the graph display function,
WEIGHT only/OFF
ePress
button.
Automatic Power Off Function
eIf you do not operate the equipment for about 30
seconds, the power will automatically switch off.
(Automatic power off function)
©If you do not step on the scale within 30
seconds after [0.0] is displayed, the
power will switch off.
Front
Personal
Memory Key
(for five individuals)
Convenient Use
Electrode
Measurements are recorded in the display box.
Recorded data can still be checked even if the display box
is separated from the weighing platform. Use this feature
if you need to consuit with professionals in sports clubs or
medical facilities.
"GRAPH" Button
"Time/DOWN" Button
"UP" Button
"SET" Button
Heel
Electrode
18
19
Download from Www.Somanuals.com. All Manuals Search And Download.
BF-562海外GB+D面付解除 ページ21
Guest Mode: Measuring without pre-set data
How to Change the Calendar
Changing the calendar settings
To set your details for
Display the calendar.
Finish changing
the calendar.
To Start Measuring.
While nothing is displayed,
After 0.0 kg is displayed,
personal data.
1
1 3
2
be sure to stand on the
scale platform barefoot so
that your heels touch the
center of the electrodes.
While nothing is displayed,
After the year, month and
day are displayed, "SET
TIME" and "PRESS OR
" will be displayed
press
to
U
Press
display the calendar.
U
(as right).
Following the display
instructions, record the
Change the calendar.
Highlight the clock by pressing
or
e.g. In the case of changing the "Day".
"month
",
"day
"
and "year" of
2
Press
your birth
"
",
and your
"gender" and "height".
See "Before Measurement
(Registration of Personal Data)" on
page 12 for details.
(Two short beeps will sound, then
"0.0 kg" will be displayed.)
ቢ First "your body weight"
will be displayed.
U
U
U
("SET DATE" and "PRESS OR
" will be displayed.)
(A short beep will sound.)
The display will show as the
diagram(right).
Highlight the hour by pressing
or
Highlight the calendar.
U
U
by pressing
or
Highlight the
ባ The body fat percentage
U
U
is being measured.
"Minute" by pressing
Time/DOWN Button
Them "ooooo" will appear
and disappear in succession,
U
Display
UP Button
SET Button
Press
to set the calendar.
Highlight the month.
Until the "Body Fat Percentage"
is displayed on the digital
display, move as little as
U
or
by pressing
After "PRESS SET" flashes,
possible and stand straight.
U
U
press again to finalize
ቤ Measurement is finished.
"your body weight" and the
"Body Fat Percentage" will
be displayed for about three
seconds. (Two short beeps
will sound.)
By pressing
continuously,
UU
U
the calendar.
(After flashing, the display will
disappear.)
The calendar has been
changed.
Highlight the part you want to
change.
(In this case the "Year.")
Front
Electrode
GRAPH Button
Change the figure by pressing
Heel Electrode
The BMI figure is displayed.
The unit will switch off.
or
and set it by pressing
Display
Note:When measured in the
athlete-mode, the BMI figure
will not be displayed.
U
U
U
(The next item starts to flash.)
Points to Note
a
When you want to change the month, day, hour or minute,
please follow the same procedure as for the year.
SET Button
aWhen you find you have made a mistake during
temporary registration,
ePlease press the GRAPH button. Since this operation
takes you back to the month setting, please start again.
aWhen you want to quit while changing the calendar,
ePress WEIGHT only/OFF button. The display will
disappear and the changes will be deleted.
UP Button
Time/DOWN Button
GRAPH Button
Remarks
Please change the calendar only when the initial settings were
incorrect. If you change the calendar after that, the order of
the recorded measurement results may become mixed up.
a
Only change the calendar when necessary.
20
21
Download from Www.Somanuals.com. All Manuals Search And Download.
BF-562海外GB+D面付解除 ページ23
Alteration of Personal Data
Please read this section before
altering the pre-recorded data.
To display the pre-set data
Highlight the minute altering the registration and finishing the operation.
Personal
for the chosen
1 3
Memory Key.
ቢ
ባ
When you correct only body type
When you change
(ordinary adult/athlete) and height
d d
the date of birth and gender
e.g. When you want to correct or alter the
To enter corrections for body type
The measurement
results recorded
against the Personal
Memory Key will not be
deleted.
(Adult/Athlete/Height etc)
e. g. © To change the height data as a
child grows.
Personal
Memory Key 4.
registration for the
While nothing is showing on
Press
and finalize
Press
and set
the display, press
UU
the height.
U
the height.
U
The display shows as for the
illustration(right).
When altering the date of birth or
gender
e. g. © When you try to use a Personal
Memory key which is already being
used by another individual.
The measurement
results recorded against
the Personal Memory
Key will be deleted.
(The corrected display will flash
blink and disappear.)
"CLEAR OK?" will be displayed.
*If the data of birth or gender are
altered, then the past memorised
results will also be deleted.
Press
or
The correction is finished.
Remarks
Before altering the pre-set date, ensure you have the
U
a
a
to select the
cm
correct
Memory Key.
Personal
U
Do not continuously press the
button.
SET
Press
again,
Personal Memory Key
eIf you keep the button depressed, the data may be set
incorrectly.
U
Delete the previous details
and confirm the new data.
(Two short beeps will sound.)
(After "OK" is displayed for a few
seconds, the altered display will
flash and disappear.)
set the number
by pressing
U
Display
(The next item starts to flash.)
Altering the pre-set
details.
2
Following the displayed
instructions, alter the
data.
See "Before Measurement -
Registration of Personal Data"
on page 14 for details.
The alteration is finished.
SET Button
UP Button
Time/DOWN Button
GRAPH Button
22
23
Download from Www.Somanuals.com. All Manuals Search And Download.
BF-562海外GB+D面付解除ページ25
Troubleshooting
Troubleshooting
When a malfunction is suspected, please check the following list before contacting the manufacturer/place of purchase
Operations
Recorded Measurements Refer to Page
Symptoms
Please check!
Refer to Page
Personal
Personal
Memory Key
Exchanging your
Memory Key for another individual's
Personal
Personal
Memory Key
Exchanging another individual's
Memory Key for your
©Are the batteries in place?
©Are the batteries weak?
©Is there plastic or dirt on the battery electrodes?
Personal
Memory Key nothing is displayed.
Despite pressing the
Will be deleted
22
9
s
Personal
s
s
Altering the date of birth (year, month, day) pre-set against a
Memory Key
Personal
Altering the gender (male, female) pre-set against a
Correcting the body type (athlete) pre-set against a
Memory Key
Personal
appears.
9
9
Memory Key
©The batteries are weak. Replace immediately.
Will not be deleted
Cannot be recorded
22
20
s
s
Personal
Correcting the height pre-set against a
Memory Key
s ©The batteries are weak. Replace immediately.
Entire display appears then
immediately disappears.
Measuring an individual in Guest Mode
(If the batteries are totally exhausted,
may not be displayed.)
What is the definition of 'Athlete'
When you want to delete recorded measurements.
Personal
When pressing the
Memory
Q
Q
Personal
Personal
©No data is recorded for that
Memory Key.
Memory Key.
12
14
Key button, "NO RECORD" is displayed
and immediately disappears.
s
s
Please pre-set data for that
e©Individuals who perform more than 10 hours intense aerobic eYou cannot delete measurements without altering the pre-set
exercise a week, with a resting pulse of below 60 beats per
minute.
data.
While performing a measurement,
When "CLEAR OK?" is displayed while altering
©Individuals who are performing slightly less than 10 hours of
intense aerobic exercise a week, but who have been
exercising at such levels for much of their lives.
©NB This equipment is not suitable for professional athletes or
body builders.
-OL OVER LOAD -1.1
,
ERROR
0.0
or
©Ensure that you step on after
kg is displayed?
Q
Personal
the
data.
is displayed.
Personal
eThe registered
data will be altered and all the
recorded measurements will be deleted.
©Are the pre-set details correct?
12
14
14
14
15
Personal
©Did you select another individual's
Memory Key?
While performing a measurement,
ERROR
To check your past measurements.
©Did you perform the measurement with your socks on?
Q
s ©Were the soles of your feet clean?
or "-----" is displayed
GRAPH
ePress the
button.
If you press another individual's Personal Memory Key...
©Your body fat percentage exceeds the measurement range. (In this case
Q
(See "Graph Display Function" on page 18.)
measurement is impossible.)
Personal
ePress your correct
Memory Key button.
If your body fat percentage borders on the obese level in
the healthy body fat range.
eCompare the reading with past data,to see whether this is
simply a fluctuation in your data or not. If in doubt do not
attempt to evaluate the data yourself, but seek the advice of a
suitably qualified professional.
Q
While performing a measurement,
©The maximum weight limit of 136 kg has been exceeded. (In this case
If you press one of the keys by accident,
26
Q
s
OL OVER LOAD
measurement is impossible.)
is displayed.
WEIGHT Only/OFF
eThen press the
to unit off.
key
While recording a measurement,
"NOT RECORDED" is displayed.
14
16
Personal
©Did you press the wrong
Memory Key?
If you press the Time/DOWN key accidentally,
s ©Are the measurement results very different from previous results?
Q
eWait for the unit to turn off automatically.
While performing a measurement
the power switches off. (The
display disappears.)
©Did you move during the measurement?
©Did you step on the scale platform before
©Were you performing a measurement with your socks on?
When measuring more than 5 individuals.
Q
0.0
14
kg was displayed?
s
When you want to measure body weight only.
Q
eMeasurement results for up to 5 individuals can be recorded.
Measure further individuals using the "Guest Mode". (Please
note: the "Guest Mode"does not allow their measurements to
be recorded.).
WEIGHT Only/OFF
ePress the
button. (See page 19 for
details).
After replacing the batteries,
or nothing is displayed.
9
(21)
(10)
Time/DOWN
©Press the
button and check the calendar, date and time.
•If the date or time is incorrect, please correct it. (See page 21.)
•If "SET DATE" is displayed, set the calendar. (See page 10.)
Personal
In order to delete the data registered against a
Memory Key,
Q
s
When you find you have made a mistake during
registration or setting.
Q
eReset all the
Personal details for that Memory Key.
WEIGHT Only/OFF
ePress the
button.
When you just want to see past records without
performing a measurement.
eWait until the power switches off after about 40 seconds
(Automatic Power Off Function) then please start the
operation again.
Q
After replacing the batteries,
"SET DATE" is displayed.
9
(10)
©Please set the calendar.
s
s
s
GRAPH
ePress the
button.
(See "Graph Display Function" on page 18.)
If you press a button, “ERROR” is
displayed.
8
©Please check the connection between the display box and the scale platform.
©No data was recorded at the time that the cursor is pointing to.
While displaying graphs,
"NO DATA" is displayed.
18
24
25
Download from Www.Somanuals.com. All Manuals Search And Download.
BF-562海外GB+D面付解除ページ27
Specifications
Model
©This product is not legal for trade.
BF-562
Maximum Weight Limit
Minimum Graduations
136kg 21st6lb 300lb
0 ~ 136kg in 100g increments
0 ~ 21st6lb in 0.2lb increments
0 ~ 300lb in 0.2lb increments
Body Fat Percentage Measurement 0.1% increments (1.0% ~ 75.0%)
Male/Female/Athlete
Personal Memory Details
Date of Birth, Calendar,
Height (100 ~ 220cm: in 1 cm increments)
Power Source
AA Dry Cell Batteries (R6P) x 4
DC6V/Maximum 60mA
Power Consumption
<Points to Note:> Instructions for registration of date of birth
©You can register dates of birth for individuals aged from one to 90 years. (For
individuals aged 91 years or older, register the birthday so that he / she is 90
years old.)
For individuals aged six or younger or 70 or older, it is recommended that you
observe the changes for reference purposes only.
27
26
Download from Www.Somanuals.com. All Manuals Search And Download.
|