Sunrise Medical Camping Equipment IC 6623 User Manual

®
Guardian Full-Length, Clamp-on Telescoping Rails  
User Instructions  
Model IC-6623  
RISK OF SERIOUS INJURY. When using side rails, only use side rails that can be  
positioned so that the gap between the side rails is large enough that the trunk  
and hips can easily pass through it. Make sure when raising the bed, head sec-  
tion or foot section does not create any of the previously described gaps.  
RISK OF SERIOUS INJURY OR DEATH. If side rail is used, follow guidelines in  
rail User's Manual. Use of side rail can expose patient to risk of suffocation  
if head becomes trapped between mattress and side rail.  
POSSIBLE INJURY. Make sure side rails are secured properly before using bed.  
RISK OF SERIOUS INJURY. Individuals with physical limitations who cannot  
prevent themselves from rolling or climbing out of the bed may require other  
means of safe positioning.  
POSSIBLE DAMAGE OR INJURY. Do not use the side rails as handles when  
moving the bed.  
POSSIBLE DAMAGE OR INJURY. Side rails do not fall within any weight limita-  
tions and may be damaged if excessive pressure is placed on them. Side rails  
are for the purpose of aiding in turning and repositioning within the bed and  
are not intended to be used for restraint purposes.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ASSEMBLY INSTRUCTIONS (FIGURE 1)  
1. Remove the mattress from the bed.  
2. Place the bed in the flat position.  
RISK OF SERIOUS INJURY OR DEATH. When using side rails, use a mattress thick  
enough and wide enough so that the gap between the top of the mattress and  
the bottom of the side rails and the gap between the side of the mattress and  
the side rails is small enough to prevent a patient from getting his or her head  
or neck between the mattress and the side rail. Assure that articulating the  
bed, head section or foot section does not create any hazardous gaps. Failure  
to do so could result in injury or possible suffocation.  
3. Measure the width of the bed frame. Attach the two crossbrace assemblies  
together.  
4. Place the assembled crossbrace on the bed frame. Attach clamps as shown and  
tighten wing nuts until secure. Prevent the lock nut from contacting the bed  
frame.  
5. Once the crossbrace is adjusted properly, tighten the center bolts and nuts.  
6. Repeat steps 3-5 for other crossbrace. Ensure the other crossbrace is between  
62" to 64" apart as shown.  
7. The slide tube can be rotated with the locking knob on the right or left by  
rotating the slide. The bed rail can be adjusted higher or lower based on your  
rail height preference.  
RISK OF SERIOUS INJURY OR DEATH. When using side rails, only use side rails  
that can be positioned so that the gap between the headboard or foot board  
and the side rails is small enough to prevent a patient from getting his or  
her head or neck between the mattress and the side rail or large enough that  
the trunk and hips can easily pass through it. Assure that articulating the  
bed, head section or foot section does not create any hazardous gaps. Failure  
to do so could result in injury or possible suffocation.  
8. Insert the rail into the slide tubes. Pull the plunger knob to adjust the rail  
height.  
Center Bolts  
RISK OF SERIOUS INJURY OR DEATH. When using side rails, only use side rails  
in which any gaps between the rail body members are small enough to prevent  
a patient from getting his or her head or neck inside the rail body. Failure to  
do so could result in injury or possible suffocation.  
Slide Tube  
Wing  
Nuts  
RISK OF SERIOUS INJURY. When using multiple side rails on one or both  
sides of the bed, only use side rails that can be positioned so that the gap  
between the side rails is large enough that the trunk and hips can easily  
pass through it. Assure that articulating the bed head section or foot section  
does not create any hazardous gaps.  
Plunger Knob  
Figure 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sennheiser Microphone G3 100 Series User Manual
Sony Blu ray Player BDP SX1 User Manual
Sony Cassette Player XR 4803 User Manual
Sony Cell Phone 1265 9041 User Manual
Sony Computer Monitor PFM 500A1WU PFM 500A1WE PFM 500A1WJ User Manual
Spalding Fitness Equipment M881111 User Manual
Spirit Treadmill XT485 User Manual
State Industries Water Heater SUF 100 150NE User Manual
Subaru Robin Power Products Marine Sanitation System PKX201 PUMP User Manual
Sylvania Cassette Player SRCD822 User Manual