Southern Pride Smoker BBR 700 SL User Manual

Woodburning BBQ Pits and Smokers  
Gas Fired and Electric  
Equipment Specifications  
Electric Ovens . . . . . . . . . . . . . . . . . . . . . . . Pages 2 - 5  
SPK Series Gas Rotisseries . . . . . . . . . . Pages 6 - 11  
BBR Gas Smoke & Hold Ovens . . . . . . Pages 12 - 15  
BBR-700-FL Gas Rotisserie. . . . . . . . . . . . Pages 16 - 17  
XLR Series Gas Rotisseries . . . . . . . .. . Pages 18 - 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL SC-200-SM  
COOKING CAPACITIES FORTHE SC-100  
Pork Butt (7 lb.) 30 pieces 210 lb. total  
St. Louis Ribs (2.75lb.)  
w/Optional Rib Racks  
Chicken (3lb.)  
Brisket (12 lb.)  
Spare Ribs (3.5lb.)  
25 pieces  
65 pieces  
40 pieces  
15 pieces  
20 pieces  
69 lb. total  
179 lb total  
120 lb. total  
180 lb. total  
28 lb. total  
33"  
3/8"  
5
1/4"  
7
5/8"  
40  
3/4"  
55  
"
8
"
3
Front View  
Side View  
3/8"  
25  
SC-200-SM  
Electrical Requirements: 208 or 240 volts AC,  
1/4"  
4
60 hertz, 1 phase, 45 amp wiring required.  
3/8"  
5
Construction: All 18 gauge Stainless Steel.  
Chipbox: Uses hardwood chips.  
3/4”  
3/8”  
Dimensions: 55  
tall, 25  
wide, 33 deep  
5/8”  
3/8”  
Shell Dimensions: 40  
tall, 25  
wide, 33 deep  
Food Racks: Five food racks 18”x 26”  
16.25 Sq.Ft. of Cooking Surface.  
5” Spacing between food racks.  
Air Circulation: Low Velocity Convection Fan.  
Temperature Range: 100-325 degrees F.  
Approvals: UL, ULC, NSF  
Venting: Must be installed under a vent hood.  
Contact local code officials and a commercial kitchen  
ventilation contractor prior to installation.  
Top View  
3/8"  
25  
Southern Pride Distributing, L.L.C.  
2102 East Main Street - Marion, Illinois 62959  
Phone: 618-997-9348  
Fax:  
618-993-5960  
Sales: 800-851-8180  
Service: 800-437-2679 Service Fax: 618-993-0378  
Revised 9/15/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL SC-600-SM  
COOKING CAPACITIES FOR THE SC-600  
Pork Butt (7 lb.) 96 pieces 672 lb. total  
St. Louis Ribs (2.75lb.)  
w/Optional Rib Racks  
Chicken (3lb.)  
Brisket (12 lb.)  
Spare Ribs (3.5lb.)  
112 pieces  
240 pieces  
200 pieces  
48 pieces  
48 pieces  
308 lb. total  
660 lb total  
600 lb. total  
576 lb. total  
168 lb. total  
1/4"  
34  
55"  
6"  
3/4"  
58  
3/4"  
64  
3/4"  
58  
1/4"  
77  
1/2"  
12  
1/2"  
12  
Side View  
Front View  
SC-600-SM  
Electrical Requirements: 208 or 240 volts AC,  
55"  
60 hertz, 1 phase, 45 amp wiring required.  
Construction: All 18 gauge Stainless Steel.  
Chipbox: Uses small logs, chunks or chips.  
1/4”  
1/4”  
Dimensions: 72  
tall, 55 wide, 34  
deep  
3/4”  
1/4”  
Shell Dimensions: 58  
tall, 55 wide, 34  
deep.  
"
4
ID  
Food Racks: Eight food racks 33 1/2”x 31”  
57.7 Sq.Ft. of Cooking Surface.  
5” Spacing between food racks.  
5/8"  
3
Air Circulation: Low Velocity Convection Fan.  
Temperature Range: 100-325 degrees F.  
Approvals: UL, ULC, NSF  
Top View  
7/8"  
11  
Venting: Must be installed under a vent hood.  
Contact local code officials and a commercial kitchen  
ventilation contractor prior to installation.  
Southern Pride Distributing, L.L.C.  
2102 East Main Street - Marion, Illinois 62959  
Phone: 618-997-9348  
Fax: 618-993-5960  
Sales: 800-851-8180  
Service: 800-437-2679 Service Fax: 618-993-0378  
Revised 9/15/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL DH-65  
COOKING CAPACITIES FOR THE DH-65  
St. Louis Ribs (2.75lb.)  
Baby Back Ribs (1.75lbs) 65 pieces  
65 pieces  
179 lb total  
114 lb total  
Following Capacities Possible with Optional Flat Racks  
Pork Butt (7 lb.)  
Chicken (3lb.)  
Brisket (12 lb.)  
30 pieces  
40 pieces  
15 pieces  
210 lb. total  
120 lb. total  
180 lb. total  
33"  
3/8"  
5
1/4"  
7
5/8"  
40  
3/4"  
55  
"
8
"
3
Front View  
Side View  
3/8"  
25  
DH-65  
Electrical Requirements: 208 or 240 volts AC,  
60 hertz, 1 phase, 45 amp wiring required.  
1/4"  
4
Construction: All 18 gauge Stainless Steel.  
3/8"  
5
Chipbox: Uses hardwood chips.  
3/4”  
3/8”  
Dimensions: 55  
Shell Dimensions: 40  
tall, 25  
5/8”  
wide, 33 deep  
3/8”  
tall, 25  
wide, 33 deep  
Food Racks: Five standard rib racks 18”x 26”  
5 Optional Flat Racks 16.25 Sq.Ft. of Cooking Surface.  
5” Spacing between food racks.  
33"  
Air Circulation: Low Velocity Convection Fan.  
Temperature Range: 100-325 degrees F.  
Approvals: UL, ULC, NSF  
Venting: Must be installed under a vent hood.  
Contact local code officials and a commercial kitchen  
ventilation contractor prior to installation.  
Top View  
Southern Pride Distributing, L.L.C.  
2102 East Main Street - Marion, Illinois 62959  
Phone: 618-997-9348  
Fax:  
618-993-5960  
Sales: 800-851-8180  
Service: 800-437-2679 Service Fax: 618-993-0378  
Revised 9/15/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL SPK-280-SL  
COOKING CAPACITIES FOR THE SPK-280  
Pork Butt (7 lb.) 48 pieces 336 lb. total  
St. Louis Ribs (2.75lb.)  
w/Optional Rib Racks  
Chicken (3lb.)  
Brisket (12 lb.)  
Spare Ribs (3.5lb.)  
48 pieces  
80 pieces  
64 pieces  
24 pieces  
36 pieces  
132 lb. total  
220 lb total  
192 lb. total  
288 lb. total  
126 lb. total  
73 3/4"  
10"  
39"  
65 3/4"  
Optional Smoke  
Extractor  
Optional Smoke  
Extractor  
8"  
2 1/2"  
NOTE:  
Drawings Show  
the Optional  
12"  
Smoke Extractor  
on SLSE Models.  
Electrical  
Connection  
for VSP Hood  
22"  
49"  
68"  
Shown with  
Optional  
Digital  
Controls  
25 1/2"  
19"  
19"  
Front View  
Side View  
Electrical  
Connection  
for VSP Hood  
SPK-280-SL  
Electrical Requirements: 120 volts AC, 60 hertz,  
1 phase, 15 amp wiring required.  
Gas Requirements: 75,000 btu, 1/2 NPT  
Construction: Inner Liner: 14 gauge H.R. Steel  
or 14 gauge Stainless Steel. Exterior: 22-gauge  
Polished Stainless Steel  
5 1/2"  
22"  
"
7
12 1/2"  
6Flue  
10Flue  
Firebox: 14” Diameter 1/4” thick H.R. pipe.  
1/4” thick firebox door. Uses wood logs or charcoal.  
Capacity: 2-3 logs 4-6” dia. 12-16” long.  
73 3/4"  
65 3/4"  
19 1/2"  
Dimensions: 68” tall, 51” wide, 73 3/4” deep  
(including covers) w/19” legs  
Shell Dimensions: 49” tall, 39” wide, 65 ” long.  
NOTE:  
3/4  
Dimensions Show  
position of the 10”  
flue on the optional  
smoke extractor on  
the -SLSE Model.  
16"  
Food Racks: Rotisserie with four (4) hanger racks,  
each with three (3) 12”x 30” food racks (12 Total).  
Sixty Three (30)Sq.Ft. of Cooking Surface.  
1/2  
3
” Spacing between food racks.  
17"  
Air Circulation: Low Velocity Convection Fan.  
Temperature Range: 100-325 degrees F.  
Burner: Electronic Pilot Gas Burner  
(Specify Natural or L.P. gas.)  
Approvals: UL, ULC, NSF  
51"  
Top View  
Venting: See back page for venting instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPK-280-SL  
VENTING INSTALLATION  
2
VSP HOOD SYSTEM: Purchased through Southern Pride  
4
VSP HOODS are U/L Listed to the applicable  
Southern Pride oven models and are NSF Certified.  
3 SPECIFY ROOF PITCH  
WHEN ORDERING  
HOOD SYSTEM TO INCLUDE:  
1. Ventilation Hood  
6
2. Two speed fan (1380/2000)  
3. Curb with vented extension and hinge kit  
(Specify roof pitch)  
5
1
4. Grease capture trough  
5. Combustion chamber flue vent  
SUPPLIED BY CUSTOMER:  
SPK-280-SL with recommended  
optional VSP Vent Hood System.  
6. Duct from hood to fan  
NOTE: If you have a duct longer than 10 feet or an elbow in your duct  
your installation, it may require a larger capacity exhaust fan. Please  
specify your duct requirements when ordering the VSP Hood System.  
ALL MODELS MAY ALSO BE INSTALLED UNDER A CANOPY HOOD RATED  
FOR COMMERCIAL COOKINGAPPLIANCES.  
NOTE: THE SIX I NCH ALL FUEL CHIMNEY  
SHOULD EXTEND ATLEAST3’ ABOVE THE  
HIGHEST SIDE OF THE ROOF OPENING  
AND BE AT LEAST2’ HIGHER THAN ANY  
PORTION OF THE BUILDING WITHIN 10’.  
HORIZON TAL.  
THROUGHTHE WALL -  
RAI N  
CAP  
DIRECT VENT INSTALLATION  
NOTE 1. When installing an Oven through a  
wall constructed of combustible material, use  
the Southern Pride Insulation Kit between  
the oven and the wall.  
6”ALL  
FUEL  
CHIMNEY  
EXHAUS T  
FAN  
2. The room that the face of the oven is installed  
into should have a balanced or positive air pressure.  
If the room has negative air pressure, smoke could  
escape into the room during operation.  
NOTE: THE 10 ” ALL  
FUEL SMOKE EX-  
TRACTOR CHIMNEY  
TE R M IN AT E S A T  
THE ROOF CURB  
SUPPLIED BY SOUTHERN PRIDE: (*)  
Smoke Extractor Damper with 10” chimney adapter plate  
10” ALL FUEL SMOKE  
EXTRACTOR CHIMNEY  
SUPPLIED BY CUSTOMER:  
6” All Fuel Chimney, 6” Rain Cap, and all accessories  
necessary for installation of the 6” chimney.  
10” All Fuel Chimney, Exhaust Fan (NOTE: Fan must  
be listed for use as a commercial kitchen ventilator),  
fan curb, and all accessories necessary for installation  
of the smoke extractor system.  
The oven’s minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top, 48"  
from front, and 2" on back. Minimum clearances are 18" to chimney connector and to smoke extractor chimney  
connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from the  
oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can be  
reduced to 2" on left side.) May be installed through a combustible wall with zero clearance with BBR kit No. 2099.  
ANY VENTILATION SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. CONSULT WITH  
LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION CONTRACTOR PRIOR TO INSTALLATION.  
Southern Pride Distributing, L.L.C.  
2102 East Main Street - Marion, Illinois 62959  
Phone: 618-997-9348  
Fax: 618-993-5960  
Sales: 800-851-8180  
Service: 800-437-2679 Service Fax: 618-993-0378  
9/1/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL SPK-500-SL  
COOKING CAPACITIES FOR THE SPK-500  
Pork Butt (7 lb.) 80 pieces 560 lb. total  
St. Louis Ribs (2.75lb.)  
w/Optional Rib Racks  
Chicken (3lb.)  
Brisket (12 lb.)  
Spare Ribs (3.5lb.)  
75 pieces  
160 pieces  
120 pieces  
40 pieces  
60 pieces  
206 lb. total  
440 lb total  
360 lb. total  
480 lb. total  
210 lb. total  
52 1/4"  
75 1/4"  
10"  
67 1/4"  
Optional Smoke  
Extractor  
Optional Smoke  
Extractor  
2 1/2"  
NOTE:  
11"  
Drawings Show  
the Optional  
Smoke Extractor  
on SLSE Models.  
Electrical  
Connection  
for VSP Hood  
21"  
51 1/4"  
70 1/4"  
12"  
Shown with Optional  
Digital Controls  
19"  
19"  
25 1/2"  
Front View  
Side View  
Electrical  
Connection  
for VSP Hood  
SPK-500-SL  
5 1/2"  
Electrical Requirements: 120 volts AC, 60 hertz,  
1 phase, 15 amp wiring required.  
"
10  
5 1/2"  
Gas Requirements: 75,000 btu, 1/2 NPT  
12 1/2"  
Construction: Inner Liner: 14 gauge H.R. Steel  
or 14 gauge Stainless Steel. Exterior: 22-gauge  
Polished Stainless Steel  
22"  
6Flue  
10Flue  
Firebox: 14” Diameter 1/4” thick H.R. pipe.  
1/4” thick firebox door. Uses wood logs or charcoal.  
Capacity: 2-3 logs 4-6” dia. 12-16” long.  
75 1/4"  
26 1/8"  
1/4  
1/4  
1/4  
Dimensions: 70 ” tall, 64 ” wide, 75 ” deep  
NOTE:  
67 1/4"  
(including covers) w/19” legs  
Shell Dimensions: 57 ” tall, 52 ” wide, 67 ” long  
Dimensions Show  
position of the 10”  
flue on the optional  
smoke extractor on  
the -SLSE Model.  
1/4  
1/4  
1/4  
.
16"  
Food Racks: Rotisserie with five (3) hanger racks,  
each with three (3) 12”x 42” food racks (15 Total).  
52.5 Sq.Ft. of Cooking Surface.  
1/2  
3
” Spacing between food racks.  
17"  
Air Circulation: Low Velocity Convection Fan.  
Temperature Range: 100-325 degrees F.  
Burner: Electronic Pilot Gas Burner  
(Specify Natural or L.P. gas.)  
Approvals: UL, ULC, NSF  
64 1/2"  
Top View  
Venting: See back page for venting instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPK-500-SL  
VENTING INSTALLATION  
2
VSP HOOD SYSTEM: Purchased through Southern Pride  
4
VSP HOODS are U/L Listed to the applicable  
Southern Pride oven models and are NSF Certified.  
3 SPECIFY ROOF PITCH  
HOOD SYSTEM TO INCLUDE:  
1. Ventilation Hood  
2. Two speed fan (1380/2000)  
3. Curb with vented extension and hinge kit  
(Specify roof pitch)  
6
5
1
4. Grease capture trough  
5. Combustion chamber flue vent  
SUPPLIED BY CUSTOMER:  
SPK-500-SL with recommended  
optional VSP Vent Hood System.  
6. Duct from hood to fan  
NOTE: If you have a duct longer than 10 feet or an elbow in your duct  
your installation, it may require a larger capacity exhaust fan. Please  
specify your duct requirements when ordering the VSP Hood System.  
ALL MODELS MAY ALSO BE INSTALLED UNDER A CANOPY HOOD RATED  
FOR COMMERCIAL COOKINGAPPLIANCES.  
NOTE: THE SIX I NCH ALL FUEL CHIMNEY  
SHOULD EXTEND ATLEAST3’ ABOVE THE  
HIGHEST SIDEOF THE ROOF OPENING  
AND BE AT LEAST2’ HIGHER THAN ANY  
PORTION OF THE BUILDING WITHIN 10’.  
HORIZON TAL.  
THROUGHTHE WALL -  
DIRECT VENT INSTALLATION  
RAI N  
CAP  
NOTE 1. When installing an Oven through a  
wall constructed of combustible material, use  
the Southern Pride Insulation Kit between  
the oven and the wall.  
6” ALL  
FUEL  
CHIMNEY  
EXHAUS T  
FAN  
2. The room that the face of the oven is installed  
into should have a balanced or positive air pressure.  
If the room has negative air pressure, smoke could  
escape into the room during operation.  
NOTE: THE 10 ” ALL  
FUEL SMOKE EX-  
TRACTOR CHIMNEY  
TE R M IN AT E S A T  
THE ROOF CURB  
SUPPLIED BY SOUTHERN PRIDE: (*)  
Smoke Extractor Damper with 10” chimney adapter plate  
10 ” ALL FUEL SMOKE  
EXTRACTOR CHIMNEY  
SUPPLIED BY CUSTOMER:  
6” All Fuel Chimney, 6” Rain Cap, and all accessories  
necessary for installation of the 6” chimney.  
10” All Fuel Chimney, Exhaust Fan (NOTE: Fan must  
be listed for use as a commercial kitchen ventilator),  
fan curb, and all accessories necessary for installation  
of the smoke extractor system.  
The oven’s minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top, 48"  
from front, and 2" on back. Minimum clearances are 18" to chimney connector and to smoke extractor chimney  
connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from the  
oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can be  
reduced to 2" on left side.) May be installed through a combustible wall with zero clearance with BBR kit No. 2099.  
ANY VENTILATION SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. CONSULT WITH  
LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION CONTRACTOR PRIOR TO INSTALLATION.  
Southern Pride Distributing, L.L.C.  
2102 East Main Street - Marion, Illinois 62959  
Phone: 618-997-9348  
Fax: 618-993-5960  
Sales: 800-851-8180  
Service: 800-437-2679 Service Fax: 618-993-0378  
9/1/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL SPK-700-SL  
COOKING CAPACITIES FORTHE SPK-700  
Pork Butt (7 lb.) 96 pieces 672 lb. total  
St. Louis Ribs (2.75lb.)  
w/Optional Rib Racks  
Chicken (3lb.)  
Brisket (12 lb.)  
Spare Ribs (3.5lb.)  
126 pieces  
270 pieces  
156 pieces  
48 pieces  
90 pieces  
346 lb. total  
742 lb total  
468 lb. total  
576 lb. total  
315 lb. total  
Electrical  
Connection  
for VSP Hood  
83 1/4"  
10"  
58 3/8"  
75 1/4"  
Optional Smoke  
Extractor  
Optional Smoke  
Extractor  
2 1/2"  
NOTE:  
Drawings Show  
the Optional  
14"  
Smoke Extractor  
on SLSE Models.  
22"  
56"  
75"  
Shown with Optional  
Digital Controls  
1/2"  
19"  
19"  
28  
Front View  
Side View  
Electrical  
Connection  
for VSP Hood  
SPK-700-SL  
Electrical Requirements: 120 volts AC, 60 hertz,  
1 phase, 15 amp wiring required.  
Gas Requirements: 75,000 btu, 1/2 NPT  
Construction: Inner Liner: 14 gauge H.R. Steel  
or 14 gauge Stainless Steel. Exterior: 22-gauge  
Polished Stainless Steel  
1/2  
5
"
11 1/2"  
1/2"  
1/2"  
5
12  
Optional Smoke  
Extractor  
Firebox: 10 ga. H.R. steel with 10 ga. H.R. firebox  
door. Uses wood logs or charcoal.  
29 1/4"  
Capacity: 3-4 logs 4-6” dia. 12-16” long.  
83 1/4"  
75 1/4"  
NOTE:  
3/8  
1/4  
Dimensions: 75” tall, 72 ” wide, 83 ” deep  
Dimensions Show  
position of the 10”  
flue on the optional  
smoke extractor on  
the -SLSE Model.  
14"  
(including covers) w/19” legs  
3/8  
1/4  
Shell Dimensions: 56” tall, 58 ” wide, 75 ” long  
.
19"  
Food Racks: Rotisserie with six (6) hanger racks,  
each with three (3) 12”x 48” food racks (18 Total).  
72 Sq.Ft. of Cooking Surface.  
1/2  
3
” Spacing between food racks.  
19"  
Air Circulation: Low Velocity Convection Fan.  
Temperature Range: 100-325 degrees F.  
Burner: Electronic Pilot Gas Burner  
(Specify Natural or L.P. gas.)  
72 3/8"  
Approvals: UL, ULC, NSF  
Top View  
Venting: See back page for venting instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPK-700-SL  
VENTING INSTALLATION  
2
VSP HOOD SYSTEM: Purchased through Southern Pride  
4
VSP HOODS are U/L Listed to the applicable  
Southern Pride oven models and are NSF Certified.  
3 SPECIFY ROOF PITCH  
HOOD SYSTEM TO INCLUDE:  
1. Ventilation Hood  
6
2. Two speed fan (1380/2000)  
3. Curb with vented extension and hinge kit  
(Specify roof pitch)  
5
1
4. Grease capture trough  
5. Combustion chamber flue vent  
SPK-700-SL with recommended  
optional VSP Vent Hood System.  
SUPPLIED BY CUSTOMER:  
6. Duct from hood to fan  
NOTE: If you have a duct longer than 10 feet or an elbow in your duct  
your installation, it may require a larger capacity exhaust fan. Please  
specify your duct requirements when ordering the VSP Hood System.  
ALL MODELS MAY ALSO BE INSTALLED UNDER A CANOPY HOOD RATED  
FOR COMMERCIAL COOKINGAPPLIANCES.  
NOTE: THE SIX I NCH ALL FUEL CHIMNEY  
SHOULD EXTEND ATLEAST3’ ABOVE THE  
THROUGHTHE WALL -  
DIRECT VENT INSTALLATION  
RAIN  
CAP  
HIGHEST SIDE OF THE ROOF OPENING  
AND BE AT LEAST 2’ HIGHER THAN ANY  
PORTION OF THE BUILDING WITHIN 10’.  
HORIZON TAL.  
NOTE 1. When installing an Oven through a  
wall constructed of combustible material, use  
the Southern Pride Insulation Kit between  
the oven and the wall.  
6”ALL  
FUEL  
CHIMNEY  
EXHAUS T  
FAN  
2. The room that the face of the oven is installed  
into should have a balanced or positive air pressure.  
If the room has negative air pressure, smoke could  
escape into the room during operation.  
NOTE: THE 10 ” ALL  
FUEL SMOKE EX-  
TRACTOR CHIMNEY  
TE R M IN AT E S A T  
THE ROOF CURB  
SUPPLIED BY SOUTHERN PRIDE: (*)  
Smoke Extractor Damper with 10” chimney adapter plate  
10 ” ALL FUEL SMOKE  
EXTRACTOR CHIMNEY  
SUPPLIED BY CUSTOMER:  
6” All Fuel Chimney, 6” Rain Cap, and all accessories  
necessary for installation of the 6” chimney.  
10” All Fuel Chimney, Exhaust Fan (NOTE: Fan must  
be listed for use as a commercial kitchen ventilator),  
fan curb, and all accessories necessary for installation  
of the smoke extractor system.  
The oven’s minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top, 48"  
from front, and 2" on back. Minimum clearances are 18" to chimney connector and to smoke extractor chimney  
connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from the  
oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can be  
reduced to 2" on left side.) May be installed through a combustible wall with zero clearance with BBR kit No. 2099.  
ANY VENTILATION SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. CONSULT WITH  
LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION CONTRACTOR PRIOR TO INSTALLATION.  
Southern Pride Distributing, L.L.C.  
2102 East Main Street - Marion, Illinois 62959  
Phone: 618-997-9348  
Fax: 618-993-5960  
Sales: 800-851-8180  
Service: 800-437-2679 Service Fax: 618-993-0378  
9/1/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL BBR-79-1  
COOKING CAPACITIES FOR THE BBR-79-1  
Pork Butt (7 lb.)  
24 pieces  
24 pieces  
64 pieces  
32 pieces  
16 pieces  
20 pieces  
168 lb. total  
66 lb. total  
176 lb. total  
96 lb. total  
192 lb. total  
70 lb. total  
St. Louis Ribs (2.75lb.)  
with Optional Rib Racks  
Chicken (3lb.)  
Brisket (12 lb.)  
Spare Ribs (3.5lb.)  
1/2"  
75  
Electrical  
Connection  
for VSP Hood 1/2"  
Optional Smoke  
Extractor  
Optional Smoke  
Extractor  
10"  
1/2"  
10"  
3"  
1/4"  
51  
1/2"  
75  
1/2"  
65  
1/2"  
4
30"  
1/4  
"
14  
Front View  
Side View  
3/4"  
33  
BBR-79-1  
Electrical Requirements: 120 volts AC,  
60 hertz, 1 phase, 15 amp wiring required.  
Gas Requirements: 75,000 btu, 1/2 NPT  
Construction: Inner Liner: 14 gauge H.R.  
Steel or 14 gauge Stainless Steel. Exterior:  
22-gauge Polished Stainless Steel  
Firebox: 10 ga. H.R. steel with 10 ga. H.R.  
firebox door. Uses wood logs or charcoal.  
Capacity: 1-2 logs, 4”dia. 12-16” long.  
20"  
Electrical  
Connection  
for VSP Hood  
"
9
6 1/2  
"
22"  
6"  
20"  
NOTE:  
Dimensions Show  
position of the 10”  
flue on the optional  
smoke extractor on  
the -SLSE Model.  
1/2  
1/2  
3/4"  
Dimensions: 75 ” tall, 75 ” wide,  
33  
3/4  
33 ” deep (including covers)  
Shell Dimensions: 51 ” tall, 75 ” wide,  
1/4  
1/2  
1/2  
75 ” long  
.
Food Racks: Rotisserie with five (4)  
hanger racks, each with three (2) 8”x 32”  
food racks (8 Total). 14 Sq.Ft. of Cooking  
22"  
1/2  
Surface. 4  
” Spacing between food racks.  
1/2"  
75  
*
Air Circulation: One Convection Fan.  
Temperature Range: 100-325 degrees F.  
Burner: Electronic Pilot Gas Burner  
(Specify Natural or L.P. gas.)  
Top View  
*
Approvals: UL, ULC, NSF  
Venting: See back page for venting instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBR-79-1  
VENTING INSTALLATION  
2
4
VSP HOOD SYSTEM: Purchased through Southern Pride  
VSP HOODS are U/L Listed to the applicable  
Southern Pride oven models and are NSF Certified.  
6
HOOD SYSTEM TO INCLUDE:  
1. Ventilation Hood  
2. Two speed fan (1380/2000)  
3. Curb with vented extension and hinge kit  
(Specify roof pitch)  
1
13/32"  
5
48  
4. Grease capture trough  
5. Combustion chamber flue vent  
1/32"  
18  
20"  
SUPPLIED BY CUSTOMER:  
6. Duct from hood to fan  
NOTE: If you have a duct longer than 10 feet or an  
elbow in your duct your installation, it may require a  
larger capacity exhaust fan. Please specify your duct  
requirements when ordering the VSP Hood System.  
BBR-79-1-FL with recommended  
optional VSP Vent Hood System.  
ALL MODELS MAY ALSO BE INSTALLED UNDER A CANOPY HOOD RATED  
FOR COMMERCIAL COOKING APPLIANCES.  
The oven’s minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top,  
48" from front, and 2" on back. Minimum clearances 18" to chimney connector and to smoke extractor chimney  
connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from  
the oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can  
be reduced to 2" on left side.) May be installed through wall with zero clearance with BBR kit No. 2099.  
ANY VENTILATION SYSTEM MUST BE INSTALLED INACCORDANCE WITH LOCAL CODES.  
CONSULT WITH LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION  
CONTRACTOR PRIOR TO INSTALLATION.  
Southern Pride Distributing, L.L.C.  
2102 East Main Street - Marion, Illinois 62959  
Phone: 618-997-9348  
Fax: 618-993-5960  
Sales: 800-851-8180  
Service: 800-437-2679 Service Fax: 618-993-0378  
9/15/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL BBR-79-2-SSE  
See Specs for the larger BBR-79-3-SSE  
on the reverse side of this sheet.  
COOKING CAPACITIES FORTHE BBR-79-2-SSE  
300 Pounds Bulk Capacity of Cooked Meat  
1/8"  
41  
333/4  
"
32"  
1/2"  
34  
"
73  
7/8"  
63  
1/2"  
4
23"  
1/4"  
19  
Front View  
Side View  
1/4"  
74  
BBR-79-2-SSE  
1/2"  
48"  
Electrical Requirements: 120 volts AC,  
60 hertz, 1 phase, 15 amp wiring required.  
Gas Requirements: 75,000 btu, 1/2 NPT  
5
5/16"  
28  
7"  
Construction: Inner Liner: 14 gauge H.R.  
Steel or 14 gauge Stainless Steel. Exterior:  
22-gauge Polished Stainless Steel  
Firebox: 10 ga. H.R. steel with 10 ga. H.R.  
firebox door. Uses wood logs or charcoal.  
Capacity: 1-2 logs, 4”dia. 12” long.  
1/4  
1/4"  
20  
1/2"  
13  
Dimensions: 73” tall, 74  
” wide,  
1/2"  
12  
1/8  
1/4  
” wide,  
41 ”deep (including covers) and 19 ” legs  
5/8  
1/4  
Shell Dimensions: 44 ” tall, 74  
3/4  
33 ” long  
.
Food Racks: One 18”x24”, four 12”x 42”  
food racks (5 Total). 19.25 Sq.Ft. of Cooking  
Surface. 12” Spacing between food racks.  
Air Circulation: One Convection Fan.  
Temperature Range: 100-325 degrees F.  
Burner: Electronic Pilot Gas Burner  
(Specify Natural or L.P. gas.)  
Top View  
*
The oven’s minimum clearances from combustible materials  
Approvals: UL, ULC, NSF  
are 2" on left side, 18" on right, 18" on top, 36" from front, and 2"  
on back. Floor may be constructed of a combustible material.  
(Note: minimum clearance dimensions are from the oven cabinet,  
not from component cover.)  
Venting: Must be installed under a vent hood.  
Contact local code officials and a commercial  
kitchen ventilation contractor prior to installation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL BBR-79-3-SSE  
See Specs for the smaller  
BBR-79-2-SSE on the reverse  
side of this sheet.  
COOKING CAPACITIES FOR THE BBR-79-3-SSE  
450 Pounds Bulk Capacity of Cooked Meat  
1/8"  
41  
3/4"  
32  
1/4"  
90  
32"  
"
39  
73"  
637/8"  
1/2"  
4
191/4"  
1/4"  
19  
Side View  
Front View  
BBR-79-3-SSE  
Electrical Requirements: 120 volts AC,  
60 hertz, 1 phase, 15 amp wiring required.  
Gas Requirements: 75,000 btu, 1/2 NPT  
Construction: Inner Liner: 14 gauge H.R.  
Steel or 14 gauge Stainless Steel. Exterior:  
22-gauge Polished Stainless Steel  
1/4"  
1/4" 90  
1/4" 76  
1/2"  
5
64  
5/16"  
28  
Firebox: 10 ga. H.R. steel with 10 ga. H.R.  
firebox door. Uses wood logs or charcoal.  
Capacity: 1-2 logs, 4”dia. 12-16” long.  
27"  
32"  
1/4  
1/8  
Dimensions: 73” tall, 90 ” wide, 41  
1/2"  
12  
1/4  
deep (including covers) and 19 ” legs  
5/8 1/4  
Shell Dimensions: 44 ” tall, 90 ” wide,  
32” deep  
.
1/4"  
9
Food Racks: One 18”x 58”, four 12”x 58”  
food racks (5 Total). 26.5 Sq.Ft. of Cooking  
Surface. 12” Spacing between food racks.  
Air Circulation: One Convection Fan.  
Temperature Range: 100-325 degrees F.  
Burner: Electronic Pilot Gas Burner  
(Specify Natural or L.P. gas.)  
Top View  
The oven’s minimum clearances from combustible materials  
are 2" on left side, 18" on right, 18" on top, 36" from front, and 2"  
on back. Floor may be constructed of a combustible material.  
(Note: minimum clearance dimensions are from the oven cabinet,  
not from component cover.)  
Approvals: UL, ULC, NSF  
Venting: Must be installed under a vent hood.  
Contact local code officials and a commercial  
kitchen ventilation contractor prior to installation.  
Southern Pride Distributing, L.L.C.  
2102 East Main Street - Marion, Illinois 62959  
Phone: 618-997-9348  
Fax:  
618-993-5960  
Sales: 800-851-8180  
Service: 800-437-2679 Service Fax: 618-993-0378  
Revised 9/1/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL BBR-700-FL  
COOKING CAPACITIES FORTHE BBR-700  
Pork Butt (7 lb.) 100 pieces 700 lb. total  
St. Louis Ribs (2.75lb.)  
Chicken (3lb.)  
Brisket (12 lb.)  
135 pieces  
156 pieces  
50 pieces  
90 pieces  
371 lb. total  
468 lb. total  
600 lb. total  
315 lb. total  
NOTE:  
Photo Shows the Optional  
Smoke Extractor on SLSE Models.  
Spare Ribs (3.5lb.)  
120"  
1/4"  
51  
Optional Smoke  
Extractor  
Optional Smoke  
Extractor  
3/4"  
9
NOTE:  
Drawings Show  
the Optional  
Smoke Extractor  
on SLSE Models.  
"
9
3/4"  
80  
71"  
Burner Cover:  
Leave room  
for access.  
16"  
53"  
19"  
19"  
Front View  
Side View  
BBR-700-SL  
Electrical Requirements: 120 volts AC,  
60 hertz, 1 phase, 15 amp wiring required.  
Gas Requirements: 125,000 btu, 1/2 NPT  
120"  
22"  
Construction: Inner Liner: 14 gauge H.R.  
Steel or 14 gauge Stainless Steel. Exterior:  
22-gauge Polished Stainless Steel  
1/2"  
3
19"  
Firebox: 20” diameter 1/4” H.R. steel  
pipe with 1/4” H.R. firebox door.  
Uses wood logs or charcoal..  
5"  
15"  
Capacity: 3-4 logs 4-6” dia. 12-16” long.  
NOTE:  
Dimensions Show  
position of the 10”  
flue on the optional  
smoke extractor on  
the -SLSE Model.  
3/4  
Dimensions: 80 ” tall, 120” wide,  
1/4"  
51  
/4  
” deep (including covers) w/19” legs  
Shell Dimensions: 52” tall, 51 ” wide,  
1/4  
1/2  
10  
"
120” long  
.
Food Racks: Rotisserie with five (5)  
hanger racks, each with three (3) 12”x 60”  
food racks (15 Total). 75 Sq.Ft. of Cooking  
1/2  
Surface. 3 ” Spacing between food racks.  
Top View  
Air Circulation: One Convection Fan.  
Temperature Range: 100-325 degrees F.  
Burner: Electronic Pilot Gas Burner  
*
(Specify Natural or L.P. gas.)  
Approvals: UL, ULC, NSF  
Venting: See back page for venting instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BBR-700-FL  
VENTING INSTALLATION  
VENTING:  
The Model BBR-700-FL  
should be vented under  
a canopy hood rated for  
commercial cooking  
applications.  
The oven’s minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top, 48"  
from front, and 2" on back. Minimum clearances 18" to chimney connector and to smoke extractor chimney  
connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from the  
oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can be  
reduced to 2" on left side.) May be installed through wall with zero clearance with BBR kit No. 2099.  
ANY VENTILATION SYSTEM MUST BE INSTALLED INACCORDANCE  
WITH LOCAL CODES. CONSULT WITH LOCAL OFFICIALS AND A COMMERCIAL  
KITCHEN VENTILATION CONTRACTOR PRIOR TO INSTALLATION.  
Southern Pride Distributing, L.L.C.  
2102 East Main Street - Marion, Illinois 62959  
Phone: 618-997-9348  
Fax: 618-993-5960  
Sales: 800-851-8180  
Service: 800-437-2679 Service Fax: 618-993-0378  
9/09/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL XLR-600-SL  
COOKING CAPACITIES FOR THE XLR-600  
Pork Butt (7 lb.) 108 pieces 756 lb. total  
St. Louis Ribs (2.75lb.)  
w/Optional Rib Racks  
Chicken (3lb.)  
Brisket (12 lb.)  
Spare Ribs (3.5lb.)  
48 pieces  
120 pieces  
144 pieces  
54 pieces  
36 pieces  
132 lb. total  
330 lb total  
432 lb. total  
648 lb. total  
126 lb. total  
87 3/8"  
79 3/8"  
33"  
Optional Smoke  
Extractor  
Optional Smoke  
Extractor  
10"  
1/  
"
5
2
NOTE:  
Drawings Show  
the Optional  
3/4"  
18  
Smoke Extractor  
on SLSE Models.  
Electrical  
Connection  
for VSP  
61"  
Hood  
22"  
76"  
15"  
15"  
19"  
FrontView  
14"  
SideView  
XLR-600-SL  
1/2"  
5
Electrical  
1/2"  
Connection  
5
Electrical Requirements: 120 volts AC, 60 hertz,  
1 phase, 15 amp wiring required.  
Gas Requirements: 125,000 btu, 1/2 NPT  
8"  
for VSP Hood  
1/2"  
16  
1/2"  
12  
Construction: Inner Liner: 12 gauge H.R. Steel or  
12 gauge Stainless Steel. Exterior: 22-gauge  
Polished Stainless Steel  
22"  
Firebox: 14” Diameter 1/4” thick H.R. pipe.  
1/4” thick firebox door. Uses wood logs or charcoal.  
1/2"  
6” Flue 10” Flue  
12  
Capacity: 3-4 logs 4”-6” dia. 12-16” long.  
Dimensions: 76” tall, 47” wide, 87 3/8” deep  
(including covers) w/ 15” legs  
NOTE:  
Dimensions Show  
position of the 10”  
flue on the optional  
smoke extractor on  
the -SLSE Model.  
87 3/8"  
14"  
79 3/8"  
Shell Dimensions: 61” tall, 33” wide, 79 3/8” long.  
16"  
Food Racks: Rotisserie with four (4) hanger racks,  
each with three (3) 18”x 22” food racks (12 Total).  
Thirty Three (33) Sq.Ft. of Cooking Surface.  
4 11/16” Spacing between food racks.  
Air Circulation: Low Velocity Convection Fan.  
Temperature Range: 100-325 degrees F.  
22"  
Burner: Electronic Pilot Gas Burner  
(Specify Natural or L.P. gas.)  
Approvals: UL, ULC, NSF  
47"  
Top View  
Venting: See back page for venting instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLR-600-SL  
VENTING INSTALLATION  
2
4
VSP HOOD SYSTEM: Purchased through Southern Pride  
3 SPECIFY ROOF PITCH  
WHEN ORDERING  
VSP HOODS are U/L Listed to the applicable  
Southern Pride oven models and are NSF Certified.  
HOOD SYSTEM TO INCLUDE:  
1. Ventilation Hood  
6
2. Two speed fan (1380/2000)  
3. Curb with vented extension and hinge kit  
(Specify roof pitch)  
5
1
4. Grease capture trough  
5. Combustion chamber flue vent  
SUPPLIED BY CUSTOMER:  
XLR-600-SL with recommended  
optional VSP Vent Hood System.  
6. Duct from hood to fan  
NOTE: If you have a duct longer than 10 feet or an elbow in your duct your  
installation, it may require a larger capacity exhaust fan. Please specify your  
duct requirements when ordering the VSP Hood System.  
ALL MODELS MAY ALSO BE INSTALLED UNDER A CANOPY HOOD RATED  
FOR COMMERCIAL COOKING APPLIANCES.  
NOTE: THE SIX INCH ALL FUEL CHIMNEY  
SHOULD EXTEND ATLEAST3’ ABOVE THE  
HIGHEST SIDE OF THE ROOF OPENING  
AND BE ATLEAST 2’ HIGHER THAN ANY  
P ORTI ON OF THE BUILDING WITHIN 10’.  
HORIZON TAL.  
THROUGHTHE WALL -  
DIRECT VENT INSTALLATION  
RAI N  
CAP  
NOTE 1. When installing an Oven through a  
wall constructed of combustible material, use  
the Southern Pride Insulation Kit between  
the oven and the wall.  
6”ALL  
FUEL  
CHIMNEY  
EXHAUS T  
FAN  
2. The room that the face of the oven is installed  
into should have a balanced or positive air pressure.  
If the room has negative air pressure, smoke could  
escape into the room during operation.  
NOTE: THE 10 ” ALL  
FUEL SMOKE EX-  
TRACTOR CHIMNEY  
TE R M IN AT E S A T  
THE ROOF CURB  
SUPPLIED BY SOUTHERN PRIDE: (*)  
Smoke Extractor Damper with 10” chimney adapter plate  
10” ALL FUEL SMOKE  
EXTRACTOR CHIMNEY  
SUPPLIED BY CUSTOMER:  
6” All Fuel Chimney, 6” Rain Cap, and all accessories  
necessary for installation of the 6” chimney.  
10” All Fuel Chimney, Exhaust Fan (NOTE: Fan must  
be listed for use as a commercial kitchen ventilator),  
fan curb, and all accessories necessary for installation  
of the smoke extractor system.  
The oven’s minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top,  
48" from front, and 2" on back. Minimum clearances 18" to chimney connector and to smoke extractor chimney  
connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from  
the oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can  
be reduced to 2" on left side.) May be installed through wall with zero clearance with BBR kit No. 2099.  
ANY VENTILATION SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. CONSULT WITH  
LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION CONTRACTOR PRIOR TO INSTALLATION.  
Southern Pride Distributing, L.L.C.  
2102 East Main Street - Marion, Illinois 62959  
Phone: 618-997-9348  
Fax: 618-993-5960  
Sales: 800-851-8180  
Service: 800-437-2679 Service Fax: 618-993-0378  
9/1/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL XLR-1000-SL  
COOKING CAPACITIES FORTHE XLR-1000  
Pork Butt (7 lb.) 144 pieces 1008 lb. total  
St. Louis Ribs (2.75lb.)  
w/Optional Rib Racks  
Chicken (3lb.)  
Brisket (12 lb.)  
Spare Ribs (3.5lb.)  
180 pieces  
264 pieces  
252 pieces  
72 pieces  
72 pieces  
495 lb. total  
726 lb total  
756 lb. total  
864 lb. total  
252 lb. total  
3/8"  
87  
79 3/8"  
1/4  
55  
"
Optional Smoke  
Extractor  
Optional Smoke  
Extractor  
10"  
"
3
NOTE:  
Drawings Show  
the Optional  
17"  
Smoke Extractor  
on SLSE Models.  
Electrical  
Connection  
for VSP  
22"  
Hood  
61”  
76"  
15"  
1/2"  
15"  
14  
Front View  
Side View  
Electrical  
Connection  
for VSP Hood  
XLR-1000-SL  
Electrical Requirements: 120 volts AC, 60 hertz,  
1 phase, 15 amp wiring required.  
"
11  
6"  
Gas Requirements: 150,000 btu, 1/2 NPT  
6"  
1/2"  
12  
Construction: Inner Liner: 12 gauge H.R. Steel or  
12 gauge Stainless Steel. Exterior: 22-gauge  
Polished Stainless Steel  
6” Flue  
10” Flue  
Firebox: 14” Diameter 1/4” thick H.R. pipe.  
1/4” thick firebox door. Uses wood logs or charcoal.  
Capacity: 3-4 logs 4-6” dia. 12-16” long.  
5/8"  
27  
NOTE:  
3/8  
87  
3/8"  
"
Dimensions: 76” tall, 69” wide, 87 3/8” deep  
Dimensions Show  
position of the 10”  
flue on the optional  
smoke extractor on  
the -SLSE Model.  
(including covers) w/15” legs  
Shell Dimensions: 61” tall, 55 ” wide, 79 ” long  
79  
1/4  
3/8  
.
19"  
Food Racks: Rotisserie with four (4) hanger racks,  
each with three (3) 18”x 42” food racks (12 Total).  
Sixty Three (63)Sq.Ft. of Cooking Surface.  
4 11/16” Spacing between food racks.  
14"  
Air Circulation: Convection Fan.  
Temperature Range: 100-325 degrees F.  
Burner: Electronic Pilot Gas Burner  
(Specify Natural or L.P. gas.)  
Approvals: UL, ULC, NSF  
Venting: See back page for venting instructions.  
69"  
Top View  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLR-1000-SL  
VENTING INSTALLATION  
2
VSP HOOD SYSTEM: Purchased through Southern Pride  
4
VSP HOODS are U/L Listed to the applicable  
Southern Pride oven models and are NSF Certified.  
3 SPECIFY ROOF PITCH  
WHEN ORDERING  
HOOD SYSTEM TO INCLUDE:  
1. Ventilation Hood  
2. Two speed fan (1380/2000)  
3. Curb with vented extension and hinge kit  
(Specify roof pitch)  
6
5
1
4. Grease capture trough  
5. Combustion chamber flue vent  
SUPPLIED BY CUSTOMER:  
XLR-1000-SL with recommended  
optional VSP Vent Hood System.  
6. Duct from hood to fan  
NOTE: If you have a duct longer than 10 feet or an elbow in your duct your  
installation, it may require a larger capacity exhaust fan. Please specify your  
duct requirements when ordering the VSP Hood System.  
ALL MODELS MAY ALSO BE INSTALLED UNDER A CANOPY HOOD RATED  
FOR COMMERCIAL COOKINGAPPLIANCES.  
NOTE: THE SIX INCH ALL FUEL CHIMNEY  
SHOULD EXTEND ATLEAST3’ ABOVE THE  
HIGHEST SIDEOF THE ROOF OPENING  
AND BE AT LEAS T 2’ HIGHER THAN ANY  
P ORTI ON OF THE BUILDING WI THIN 10’.  
HORIZON TAL.  
THROUGHTHE WALL -  
DIRECT VENT INSTALLATION  
RAIN  
CAP  
NOTE 1. When installing an Oven through a  
wall constructed of combustible material, use  
the Southern Pride Insulation Kit between  
the oven and the wall.  
6” ALL  
FUEL  
CHIMNEY  
EXHAUS T  
FAN  
2. The room that the face of the oven is installed  
into should have a balanced or positive air pressure.  
If the room has negative air pressure, smoke could  
escape into the room during operation.  
NOTE: THE 10ALL  
FUEL SMOKE EX-  
TRACTOR CHIMNEY  
TE R M IN AT E S A T  
THE ROOF CURB  
SUPPLIED BY SOUTHERN PRIDE: (*)  
Smoke Extractor Damper with 10” chimney adapter plate  
10 ” ALL FUEL SMOKE  
EXTR ACTOR CH IMNEY  
SUPPLIED BY CUSTOMER:  
6” All Fuel Chimney, 6” Rain Cap, and all accessories  
necessary for installation of the 6” chimney.  
10” All Fuel Chimney, Exhaust Fan (NOTE: Fan must  
be listed for use as a commercial kitchen ventilator),  
fan curb, and all accessories necessary for installation  
of the smoke extractor system.  
The oven’s minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top, 48"  
from front, and 2" on back. Minimum clearances are 18" to chimney connector and to smoke extractor chimney  
connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from the  
oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can be  
reduced to 2" on left side.) May be installed through a combustible wall with zero clearance with BBR kit No. 2099.  
ANY VENTILATION SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. CONSULT WITH  
LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION CONTRACTOR PRIOR TO INSTALLATION.  
Southern Pride Distributing, L.L.C.  
2102 East Main Street - Marion, Illinois 62959  
Phone: 618-997-9348  
Fax: 618-993-5960  
Sales: 800-851-8180  
Service: 800-437-2679 Service Fax: 618-993-0378  
9/15/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL XLR-1400-SL  
COOKING CAPACITIES FORTHE XLR-1400-SLSE  
Pork Butt (7 lb.)  
144 pieces  
150 pieces  
288 pieces  
216 pieces  
72 pieces  
1008 lb. total  
412 lb. total  
792 lb total  
648 lb. total  
864 lb. total  
420 lb. total  
St. Louis Ribs (2.75lb.)  
w/Optional Rib Racks  
Chicken (3lb.)  
Brisket (12 lb.)  
Spare Ribs (3.5lb.)  
120 pieces  
1/2"  
108  
3/4"  
55  
1/2"  
100  
Optional Smoke  
Extractor  
Optional Smoke  
Extractor  
10"  
"
6
NOTE:  
Drawings Show  
the Optional  
Smoke Extractor  
on SLSE Models.  
1/2"  
93  
Electrical  
Connection  
for VSP  
Hood  
1/2"  
75  
22"  
29"  
8"  
8"  
36"  
Front View  
Side View  
Electrical  
Connection  
for VSP Hood  
XLR-1400-SL  
Electrical Requirements: 120 volts AC, 60 hertz,  
1 phase, 15 amp wiring required.  
6"  
1/2"  
13  
Gas Requirements: 125,000 btu, 1/2 NPT  
6"  
22"  
Construction: Inner Liner: 12 gauge H.R. Steel or  
12 gauge Stainless Steel. Exterior: 22-gauge  
Polished Stainless Steel  
Firebox: 20” Diameter 1/4” thick H.R. pipe.  
1/4” thick firebox door. Uses wood logs or charcoal.  
Capacity: 3-4 logs 4-6” dia. 12-16” long.  
26"  
9"  
NOTE:  
Dimensions Show  
position of the 10”  
flue on the optional  
smoke extractor on  
the -SLSE Model.  
1/2"  
108  
1/2  
3/4”  
1/2”  
Dimensions: 93 ” tall, 69  
wide,  
108  
deep  
14"  
1/2"  
100  
(including covers) w/8” legs.  
1/2”  
3/4  
1/2  
Shell Dimensions: 75  
tall, 55 ” wide, 100 ” long.  
19"  
Food Racks: Rotisserie with six (6) hanger racks,  
each with five (5) 12”x 42” food racks (30 Total).  
105 Sq.Ft. of Cooking Surface.  
3 1/2” Spacing between food racks.  
Air Circulation: Two Low Velocity Convection Fans.  
3/4"  
26  
Temperature Range: 100-325 degrees F.  
Burner: Electronic Pilot Gas Burner  
(Specify Natural or L.P. gas.)  
Approvals: UL, ULC, NSF  
3/4"  
69  
Top View  
Venting: See back page for venting instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLR-1400-SL  
VENTING INSTALLATION  
2
VSP HOOD SYSTEM: Purchased through Southern Pride  
4
VSP HOODS are U/L Listed to the applicable  
Southern Pride oven models and are NSF Certified.  
3 SPECIFY ROOF PITCH  
WHEN ORDERING  
HOOD SYSTEM TO INCLUDE:  
1. Ventilation Hood  
2. Two speed fan (1380/2000)  
3. Curb with vented extension and hinge kit  
(Specify roof pitch)  
4. Grease capture trough  
5. Combustion chamber flue vent  
6
5
1
SUPPLIED BY CUSTOMER:  
XLR-1400-SL with  
recommended optional  
VSP Vent Hood System.  
6. Duct from hood to fan  
NOTE: If you have a duct longer than 10 feet or an elbow in your duct your  
installation, it may require a larger capacity exhaust fan. Please specify your  
duct requirements when ordering the VSP Hood System.  
ALL MODELS MAY ALSO BE INSTALLED UNDER A CANOPY  
HOOD RATED FOR COMMERCIAL COOKING APPLIANCES.  
NO TE : TH E S IX I NC H AL L F U EL C H IM N E Y  
THROUGHTHE WALL OR  
S H O UL D EX T EN D A T LE A S T 3 ’ AB O VE T HE  
H IG HE S T S ID E O F T H E R O O F O P EN IN G  
AND B E A T L E AS T 2 ’ H IG HE R T H AN AN Y  
P O R TI ON O F T H E B UILD ING W I TH IN 1 0 ’.  
HO R IZ ON TAL .  
DIRECT VENT INSTALLATION  
RAI N  
C AP  
NOTE 1. When installing an Oven through a  
wall constructed of combustible material, use  
the Southern Pride Insulation Kit between  
the oven and the wall.  
6 ” A LL  
FU EL  
C H IM NE Y  
2. The room that the face of the oven is installed  
into should have a balanced or positive air pressure.  
If the room has negative air pressure, smoke could  
escape into the room during operation.  
EX H AU S T  
FAN  
NOTE: THE 10 ” ALL  
FUEL SMOKE EX-  
TRACTOR CHIMNEY  
TE R M IN AT E S A T  
THE ROOF CURB  
SUPPLIED BY SOUTHERN PRIDE: (*)  
Smoke Extractor Damper with 10” chimney adapter plate  
1 0 ” AL L FU EL S M OK E  
E X TR AC T OR CH IM NE Y  
SUPPLIED BY CUSTOMER:  
6” All Fuel Chimney, 6” Rain Cap, and all accessories  
necessary for installation of the 6” chimney.  
10” All Fuel Chimney, Exhaust Fan (NOTE: Fan must  
be listed for use as a commercial kitchen ventilator),  
fan curb, and all accessories necessary for installation  
of the smoke extractor system.  
The oven’s minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top, 48"  
from front, and 2" on back. Minimum clearances are 18" to chimney connector and to smoke extractor chimney  
connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from the  
oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can be  
reduced to 2" on left side.) May be installed through a combustible wall with zero clearance with BBR kit No. 2099.  
ANY VENTILATION SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. CONSULT WITH  
LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION CONTRACTOR PRIOR TO INSTALLATION.  
Southern Pride Distributing, L.L.C.  
2102 East Main Street - Marion, Illinois 62959  
Phone: 618-997-9348  
Fax: 618-993-5960  
Service Fax: 618-993-0378  
9/1/04  
Sales: 800-851-8180  
Service: 800-437-2679  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MODEL XLR-1600-4-SL  
COOKING CAPACITIES FORTHE XLR-1600-4  
Pork Butt (7 lb.)  
192 pieces  
294 pieces  
432 pieces  
312 pieces  
96 pieces  
1344 lb. total  
808 lb. total  
1188 lb total  
936 lb. total  
1152 lb. total  
735 lb. total  
St. Louis Ribs (2.75lb.)  
w/Optional Rib Racks  
Chicken (3lb.)  
Brisket (12 lb.)  
Spare Ribs (3.5lb.)  
210 pieces  
1/4"  
78  
3/8"  
119  
1/4"  
64  
3/8"  
111  
Optional Smoke  
Extractor  
Optional Smoke  
Extractor  
10"  
NOTE:  
Drawings Show  
the Optional  
Smoke Extractor  
on SLSE Models.  
14"  
1/2"  
99  
1/2"  
117  
1/2"  
99  
36"  
22"  
25"  
"
311/2  
1/2"  
25  
25"  
28"  
3/4"  
41  
8"  
8"  
Front View  
Side View  
XLR-1600-4-SL  
Electrical Requirements: 120 volts AC, 60 hertz,  
8"  
6"  
1 phase, 15 amp wiring required.  
3/8"  
13  
Gas Requirements: 200,000 btu single burner or  
300,000 btu dual burner, 1/2 NPT  
6"  
22"  
Construction: Inner Liner: 12 gauge H.R. Steel or  
Stainless Steel. Exterior: 22-gauge Polished Stainless  
26"  
9"  
NOTE:  
Firebox: 20” Diameter 1/4” thick H.R. pipe.  
1/4” thick firebox door. Uses wood logs or charcoal.  
Capacity: 3-4 logs 4-6” dia. 12-16” long.  
Dimensions Show  
position of the 10”  
flue on the optional  
smoke extractor on  
the -SLSE Model.  
3/8"  
111  
14"  
1/2  
1/4”  
3/8”  
Dimensions: 117 ” tall, 78  
wide,  
119  
deep  
(including covers) w/8” legs  
19"  
1/2”  
1/4  
3/8  
Shell Dimensions: 99  
tall, 64 ” wide, 111 ” long.  
Food Racks: Rotisserie with six (6) hanger racks,  
each with seven (7) 12”x 48” food racks (42 Total).  
168 Sq.Ft. of Cooking Surface.  
323/4"  
3 1/2” Spacing between food racks.  
Air Circulation: Two Low Velocity Convection Fans.  
Temperature Range: 100-325 degrees F.  
Burner: Electronic Pilot Gas Burner  
(Specify Natural or L.P. gas.)  
1/4"  
64  
1/4"  
78  
Approvals: NSF  
Top View  
Venting: See back page for venting instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLR-1600-4-SL  
VENTING INSTALLATION  
THROUGHTHE WALL - DIRECT VENT INSTALLATION  
NOTE: THE CHIMNEY SHOULD EXTEND AT LEAST 3’  
ABOVE THE HIGHEST SIDE OF THE ROOF OPENING  
AND BE AT LEAST 2’ HIGHER THAN ANY PORTION  
OF THE BUILDING WITHIN 10’ HORIZONTALLY.  
NOTE 1. When installing an Oven through a  
wall constructed of combustible material, use  
the Southern Pride Insulation Kit between  
the oven and the wall.  
RAIN  
CAP  
6”  
ALL FUEL  
CHIMNEY  
2. The room that the face of the oven is installed  
into should have a balanced or positive air pressure.  
If the room has negative air pressure, smoke could  
escape into the room during operation.  
10” ALL  
FUEL SMOKE  
EXTRACTOR  
CHIMNEY  
(*) ONLY  
THE SMOKE  
EXTRACTOR  
DAMPER AND  
ADAPTER  
SUPPLIED BY SOUTHERN PRIDE: (*)  
Smoke Extractor Damper with 10” chimney adapter plate  
PLATE ARE  
SUPPLIED BY  
SUPPLIED BY CUSTOMER:  
6” All Fuel Chimney, 6” Rain Cap, and all accessories  
SOUTHERN  
PRIDE.  
necessary for installation of the 6” chimney. All Fuel  
Chimney, Exhaust Fan (NOTE: Fan must be listed for  
use as a commercial kitchen ventilator), fan curb, and  
all accessories necessary for installation of the smoke  
extractor system.  
The oven’s minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top, 48"  
from front, and 2" on back. Minimum clearances are 18" to chimney connector and to smoke extractor chimney  
connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from the  
oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can be  
reduced to 2" on left side.) May be installed through a combustible wall with zero clearance with BBR kit No. 2099.  
ANY VENTILATION SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. CONSULT WITH  
LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION CONTRACTOR PRIOR TO INSTALLATION.  
Southern Pride Distributing, L.L.C.  
2102 East Main Street - Marion, Illinois 62959  
Phone: 618-997-9348  
Fax: 618-993-5960  
Sales: 800-851-8180  
Service: 800-437-2679 Service Fax: 618-993-0378  
9/15/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Shindaiwa Trimmer 81601 User Manual
Sony Laptop VPCZ12 User Manual
Sony Security Camera SNC CH140 User Manual
Sony Security Camera SNC DF70N User Manual
Sony Stereo Amplifier XM D9001GTR User Manual
SPX Cooling Technologies Humidifier FSIG TS 08A User Manual
StarTechcom Switch DS154 User Manual
Sunbeam Microwave Oven SMW700 User Manual
Sun Microsystems Server X6275 User Manual
Tanaka Chainsaw ECS 290 User Manual