Feature Overview  
Benefits of Switching in SonicOS  
The SonicWALL NSA 2400MX provides a combined security and switching solution with the objective of  
improved security for all tasks. Layer 2 switching features enhance the deployment and interoperability of  
SonicWall devices within existing Layer 2 networks.  
The SonicWALL NSA 2400MX provides flexible, intelligent switching capabilities with its unique  
PortShield architecture, increased port density with 26 interfaces, and advanced switching features.  
The advanced switching features on a network security appliance provide the following benefits:  
Increased port density – With one appliance providing 26 interfaces, including 24 switch ports, you can  
decrease the number of devices on your internal network.  
Increased security across multiple switch ports – The PortShield architecture provides the flexibility to  
configure all 26 LAN switch ports into separate security zones such as LANs, WLANs and DMZs,  
providing protection not only from the WAN and DMZ, but also between devices inside the LAN.  
Effectively, each security zone has its own wire-speed ‘mini-switch’ that benefits from the protection of  
a dedicated deep packet inspection firewall.  
VLAN Trunking – Simplifies VLAN management and configuration by reducing the need to configure  
VLAN information on every switch.  
Layer 2 Discovery – Provides Layer 2 network information for all devices attached to the SonicWALL  
NSA 2400MX.  
Link Aggregation – Aggregated ports provide increased performance through load balancing when  
connected to a switch that supports aggregation, and provide redundancy when connected to a switch  
or server that supports aggregation.  
Port Security – Allows administrators to bind a trusted MAC address or multiple MAC addresses to a  
specific port to decrease unauthorized access on that port.  
Rapid Spanning Tree Protocol – Allows for redundancy in case a connection goes down, while  
preventing loops from being formed when switches or bridges are interconnected via multiple paths.  
Layer 2 Quality of Service – Allows for traffic prioritization and bandwidth management to minimize  
network delay using Cost of Service (CoS) classification, and DSCP marking.  
Port Mirroring – Allows the administrator to easily monitor and inspect network traffic on one or more  
ports.  
Rate Control / Flow Control – Back-pressure flow control on half-duplex ports and pause frame-based  
flow control on full-duplex ports allow zero packet loss under temporary traffic congestion.  
Port Security – Binding a MAC address or multiple MAC addresses to a specific port interface provides  
security, as frames whose source addresses are not contained in the table will be dropped.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Feature Overview  
How Does Switching Work on the SonicWALL NSA 2400MX?  
The switching features have their own menu group in the left navigation pane of the SonicOS management  
interface.  
Figure 1  
Switching in SonicOS – Navigation Pane  
Some switching features operate on PortShield Groups and require preliminary configuration on the  
Network > PortShield Groups page. Some operate on existing Network > Interface configurations. The  
Port Security feature uses MAC address objects. For more information about configuring these related  
features in SonicOS, see the SonicOS 5.7 Administrator’s Guide.  
For details about the operation of each switching feature, see the related section under the “Configuring  
Supported Platforms  
Switching is available on the SonicWALL NSA 2400MX running SonicOS 5.7 and higher. Switching features  
are only available on ports X2 - X25, not on X0 (LAN) or X1 (WAN).  
The hardware design of the SonicWALL NSA 2400MX includes the following elements:  
Dual core 700 MHZ CPU  
8 Gigabit Ethernet interfaces  
16 10/100 Megabit Fast Ethernet interfaces  
1 Gigabit Ethernet WAN port  
1 Gigabit Ethernet LAN port  
2 USB extension ports that support external 3G wireless cards or V.90 analog modem cards  
2 Expansion Slots for future use  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Configuring Switching  
Configuring Switching  
This section contains the following sections:  
Configuring VLAN Trunking  
VLAN trunking is supported by the IEEE 802.1Q networking standard, also called VLAN Tagging. This  
standard defines how VLANs operate with regard to Layer 2 (MAC layer) bridging. The use of VLANs and  
VLAN trunking allows multiple bridged networks to simultaneously share a single physical network while  
preserving the privacy of information in each (virtual) network. IEEE 802.1Q also refers to the  
encapsulation protocol used to implement this standard in Ethernet networks. The SonicWALL NSA  
2400MX appliance supports 802.1Q encapsulation on its VLAN trunk ports. Encapsulation, in this case,  
refers to the  
For example, a company, university, or other organization can use VLANs to create separate logical (virtual)  
networks for different departments. Each department is assigned to it’s own VLAN. The switch ports to  
which the department computers are connected are configured as members of that VLAN. When network  
traffic is sent out from a department computer, the switch adds a 32-bit VLAN tag to each data frame before  
forwarding it via a VLAN trunk port. Each switch in the network examines the VLAN tag, and uses the  
information to determine that it is a tagged frame, the priority level (defined by IEEE 802.1p), whether it  
is an Ethernet or a Token Ring frame, and the VLAN to which the frame belongs. The frame makes its way  
through the physical network until it reaches the last switch before the destination device, at which point  
the switch removes the VLAN tag and delivers the frame to its destination. This switch only delivers the  
frame via a port that is configured as a member of the same VLAN, thereby ensuring that the data is not  
leaked to any other department.  
In the above scenario, the switch ports connected to department computers are configured as members of  
a VLAN. The switch ports that are connected to other switches in the physical network are configured as  
VLAN trunk ports. This distinction means that only unassigned switch ports on the SonicWALL NSA  
2400MX appliance can function as VLAN trunk ports.  
You can enable or disable individual VLANs on the trunk ports, allowing the existing VLANs on the  
SonicWALL NSA 2400MX appliance to be bridged to respective VLANs on another switch connected via  
the trunk port. A maximum of 32 VLANs can be enabled on each trunk port.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Configuring Switching  
Figure 2 shows the Switching > VLAN Trunking page. The page displays the range of reserved VLANs in  
the Reserved VLAN Information section, details about current VLANs in the VLAN Table, and the  
VLAN trunks configured on the system in the VLAN Trunks area.  
Figure 2  
Switching > VLAN Trunking Page  
The VLAN trunking feature provides the following functions:  
Change VLAN ID’s of existing PortShield groups  
Add/delete VLAN trunk ports  
Enable/disable VLANs on the trunk ports  
The allowed VLAN ID range is 1-4094. Some VLAN IDs are reserved for PortShield use and are displayed  
in the Reserved VLAN Information table on the Switching > VLAN Trunking page.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuring Switching  
The values displayed on the Switching > VLAN Trunking page are described in Table 1.  
Table 1 VLAN Trunking Page Description  
Item  
Description  
Reserved VLAN Information  
Starting VLAN ID  
The lowest ID number in the VLAN range reserved for PortShield use. This  
VLAN range is reserved for local VLANs associated with a PortShield group.  
Ending VLAN ID  
VLAN Table  
VLAN ID  
The highest ID number in the VLAN range reserved for PortShield use.  
The ID number of the VLAN. VLAN ID 26 is the default VLAN that includes  
all LAN ports on the SonicWALL NSA 2400MX unless configured otherwise.  
Interface  
For the default VLAN that includes all LAN ports unless configured  
otherwise, the lowest interface, X0, is used.  
For other VLANs with multiple member ports, the displayed interface is  
the one configured as the PortShield interface for that PortShield group.  
For interfaces that are not assigned to a PortShield group, the port number  
of the interface is used, such as X25.  
For remote VLANs, the trunked interface and the virtual interface (called  
the VLAN Trunk Interface) are displayed in the format:  
[trunked interface]:V[virtual interface number]  
The virtual VLAN Trunk Interface is automatically created for remote  
VLANs. When the same remote VLAN is enabled on another trunk port,  
no new interface is created. All packets with the same VLAN tag ingressing  
on different trunk ports are handled by the same virtual interface.  
Member Ports  
For PortShield groups, all interfaces in the group are listed as Member  
Ports.  
For interfaces that are not assigned to a PortShield group, only the port  
number of the interface is listed as a Member Port.  
For remote VLANs, the VLAN trunk ports on which the remote VLAN is  
enabled are listed.  
Trunked  
A green check mark is displayed if the VLAN ID has been configured as  
trunked, and is enabled for trunking on all VLAN trunk ports. A VLAN can be  
enabled for trunking on an individual trunk port or a subset of all trunk ports,  
in which case the green check mark does not appear. Enabling trunking allows  
traffic for this VLAN to be sent to remote members of the VLAN who are  
connected to a different switch in the network. To enable trunking for this  
VLAN on all trunk ports, see the “Editing VLANs” section on page 12.  
Configure  
The Configure icon is enabled for rows that contain PortShield groups. When  
the Configure icon is disabled, you can edit the settings for that row on the  
Network > PortShield Groups page.  
VLAN Trunks  
Trunk Port  
The interface name is displayed in the Trunk Port column. Also, the number of  
VLAN entries that are enabled on this trunk port is given in parentheses.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuring Switching  
Item  
Description  
VLAN ID  
The VLAN ID of each VLAN enabled on the trunk port is displayed when the  
arrow next to the interface name is pointing downward. Click the right arrow  
to expand the list.  
Configure  
The Configure column shows a delete icon if the entry on the row can be  
deleted. A row containing a VLAN ID that is marked as Trunked in the VLAN  
Table will not display a delete icon.  
You can mark certain PortShield groups as “Trunked”. For information about how to do this, see the  
“Editing VLANs” section on page 12. Once the PortShield group is dismantled, the associated VLAN is  
automatically disabled on the trunk ports.  
VLANs can exist locally in the form of PortShield groups or can be totally remote VLANs. In Figure 3, the  
Network > PortShield page shows a PortShield group with X14 as the PortShield interface and X15, X16,  
and X17 as members of the PortShield group. X20 and X21 are VLAN trunk ports.  
Figure 3  
Switch Port Settings on Network > PortShield Groups Page  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuring Switching  
You can change the VLAN ID of PortShield groups on the SonicWALL NSA 2400MX appliance. This  
allows easy integration with existing VLAN numbering.  
Unlike traditional Layer 2 switches, the SonicWALL NSA 2400MX appliance does not allow changing port  
VLAN membership in an ad-hoc manner. VLAN membership of a port must be configured via PortShield  
configuration in the SonicOS management interface.  
For more information about configuring PortShield groups, see the “Configuring PortShield Interfaces”  
chapter in the SonicOS 5.7 Administrator’s Guide.  
A virtual interface (called the VLAN Trunk Interface) is automatically created for remote VLANs. When  
the same remote VLAN is enabled on another trunk port, no new interface is created. All packets with the  
same VLAN tag ingressing on different trunk ports are handled by the same virtual interface. This is a key  
difference between VLAN sub-interfaces and VLAN trunk interfaces.  
As shown in Figure 4, the Name column on the Network > Interfaces page displays the VLAN Trunk  
Interfaces for the VLAN trunks on which VLAN IDs 100 and 200 are enabled.  
Figure 4  
VLAN Trunk Interfaces on Network > Interfaces Page  
You can enable any VLAN, local or remote, on a VLAN trunk to allow bridging to to respective VLANs on  
another switch. For example, local VLAN 3787, created from a PortShield group, can be enabled on the  
VLAN trunk for port X20, which also has two remote VLANs enabled on it.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuring Switching  
Figure 5 shows the user interface while enabling the local VLAN 3787 on the trunk port, X20.  
Figure 5 Enabling a Local VLAN on a VLAN Trunk  
In Figure 6, the VLAN Table on the Switching > VLAN Trunking page displays the trunk port, X20, as a  
member of local VLAN 3787 after the VLAN is enabled on the VLAN trunk.  
Figure 6  
VLAN Table  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Configuring Switching  
Figure 7 illustrates a VLAN trunk with two trunk ports, bridging the Sales, Engineering, QA, and Finance  
VLANs through the SonicWALL NSA 2400MX. Each remote VLAN is initially enabled on VLAN trunk  
port X20, causing the creation of four virtual VLAN trunk interfaces. When these VLANs are also enabled  
on trunk port X21, no new virtual interfaces are created.  
Figure 7  
VLAN Trunk Bridging Four VLANs Through the SonicWALL NSA 2400MX  
Two Trunk Ports: Four VLANS:  
VLAN Trunk Interfaces:  
v100 - Sales  
x20: v100  
x20: v200  
x20: v300  
x20: v400  
X20, X21  
Internet  
v200 - Engineering  
v300 - QA  
v400 - Finance  
Network Security Appliance  
2400MX  
VLAN  
Trunk  
VLAN  
Trunk  
Finance  
Switch  
Switch  
Sales  
Eng  
QA  
Finance  
Sales  
QA  
Eng  
VLAN trunking interoperates with Rapid Spanning Tree Protocol (RSTP), Link Aggregation and Port  
Mirroring features. A VLAN trunk port can be mirrored, but cannot act as a mirror port itself. VLAN trunk  
ports are used to pass traffic to other networking devices. By comparison, traffic arriving on a mirror port has  
already been handled or sent to its destination, and the mirror port does not forward it again.  
You cannot enable static port security on the VLAN trunk port. When using static port security, MAC  
address objects for the trusted MAC addresses are bound to a port, and frames from other source addresses  
are dropped. This is not supported on VLAN trunk ports in this release.  
Ports configured as VLAN trunks cannot be used for any other function and are reserved for use in Layer 2  
only. For example, you cannot configure an IP Address for the trunk ports.  
When a Trunk VLAN interface has been configured on a particular trunk port, that trunk port cannot be  
deleted until the VLAN interface is removed, even though the VLAN is enabled on multiple trunk ports.  
See the following procedures:  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
 
Configuring Switching  
Editing VLANs  
To edit a VLAN, perform the following steps:  
Step 1 On the Switching > VLAN Trunking page, click the Configure icon  
in the VLAN Table row for the  
VLAN ID you want to edit.  
Step 2 In the Edit Vlan for PortShield window, do one of the following:  
Type a different VLAN ID into the Vlan ID field. You can enter any VLAN ID except the original  
system-specified VLAN ID or any others in the Reserved VLAN IDs.  
Use the VLAN ID number in the Vlan ID field, which matches the one for which you clicked the  
Configure icon.  
Step 3 To enable trunking for this VLAN, select the Trunked checkbox. To disable trunking for this VLAN, clear  
the checkbox.  
Enabling trunking allows traffic for this VLAN to be sent to remote members of the VLAN who are  
connected to a different switch in the network. The VLAN ID is automatically added to the list of VLAN  
entries for each trunk port, indicating that the VLAN is enabled on the trunk ports. Also, a green check  
mark is displayed for this VLAN in the VLAN Table on the Switching > VLAN Trunking page.  
Step 4 Click OK.  
Adding a VLAN Trunk Port  
To add a VLAN trunk port, perform the following steps:  
Step 1 On the Switching > VLAN Trunking page under VLAN Trunks, click the Add button.  
Step 2 In the Add VLAN Trunk Port window, select the port to add from the Trunk Port drop-down list.  
Step 3 Click OK.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Configuring Switching  
Enabling a VLAN on a Specific Trunk Port  
Using this method rather than the method described in “Editing VLANs” on page 12, you can specify a  
single trunk port to be used for a particular VLAN ID.  
To enable a custom VLAN ID on a specific trunk port, perform the following steps:  
Step 1 On the Switching > VLAN Trunking page under VLAN Trunks, click the Enable VLAN button.  
Step 2 In the Enable VLAN window, select a trunked port from the Trunked Port drop-down list. This is the  
port that you want to use to trunk the VLAN ID indicated in the next field.  
Step 3 In the VLAN ID field, type in the VLAN ID to be trunked. This can be a VLAN ID on another switch.  
Step 4 Click OK.  
Deleting VLAN Trunk Ports  
To delete one or more VLAN trunk ports, perform the following steps:  
Step 1 On the Switching > VLAN Trunking page under VLAN Trunks, select one or more checkboxes for the  
VLAN trunk ports you want to delete.  
Step 2 Click the Delete button.  
Step 3 Click OK in the confirmation dialog box.  
Configuring Rapid Spanning Tree  
The Rapid Spanning Tree Protocol (RSTP) is implemented to support Layer 2 network designs with  
redundant paths.  
The first Spanning Tree Protocol was defined in by IEEE 802.1D in 1990, updated in 1998, and replaced in  
2004. The 802.1D-2004 standard removed STP and replaced it with RSTP, also adding other extensions  
802.11c and 802.1t. RSTP was originally defined in 802.1w, introduced in 1998 and published in 2001. RSTP  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Configuring Switching  
allows faster spanning tree convergence after a topology change, typically within 3 times the Hello interval,  
a total of 6 seconds in the default configuration. The original STP can take 30 to 50 seconds for convergence  
after a topology change.  
SonicWALL’s RSTP implementation conforms to the IEEE 802.1D-2004 specification. The 802.1D  
specification is VLAN unaware and creates a common spanning tree (CST) that is applied to all VLANs  
present in the network. The RSTP implementation is backward compatible with the original 802.1D  
standard (STP).  
The Switching > Rapid Spanning Tree page, shown in Figure 8, displays the root bridge ID and other  
information about the root bridge. It also provides a way to configure bridge settings and port settings for  
the SonicWALL NSA 2400MX.  
See the following sections for bridge and port settings configuration information:  
Figure 8  
Switching > Rapid Spanning Tree Page  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuring Switching  
The settings displayed in the Bridge Information section of the Switching > Rapid Spanning Tree page are  
described in Table 2.  
Table 2  
RSTP Configurable Objects  
Description  
Item  
Root Bridge ID  
The root bridge ID is an 8-byte value with 2 bytes for the bridge priority  
and 6 bytes for the MAC address. The root bridge has the lowest value for  
priority among all switches in the network.  
Root Bridge  
Root Priority  
Indicates whether or not the SonicWALL NSA 2400MX is the root bridge  
in the bridged LAN. The root bridge is chosen by an election process  
among all switches in the network, based on bridge priority and bridge  
MAC address.  
Bridge priority is configurable in multiples of 4,096 with a default value of  
32,768 and maximum of 61,440. Lower numbers indicate higher priority.  
Bridge priority is the key factor in determining the root bridge. It also  
determines the designated bridge for each LAN segment when multiple  
bridges have the same path cost to the root bridge.  
Root Path Cost  
The root path cost is based on the speed of the interface that connects to  
the root bridge, and is used by RSTP to calculate the shortest path to the  
elected root bridge.  
Root Port  
The root port is the interface on a bridge that provides the shortest path  
to the root bridge.  
Root Age Time (sec)  
Root Max Age (sec)  
The root age time is the number of seconds since the last hello packet  
arrived from the root bridge.  
The root max age is the time interval without sending a hello packet after  
which a switch is assumed to be unreachable and the Spanning Tree  
network topology is updated.  
Root Forward Delay (sec)  
Root Hello Time  
The root forward delay is the time allowed for the listening and learning  
state. It is also the time that it takes to convert an interface from a blocking  
state to a forwarding state. The default is 15 seconds.  
The root hello time is the time interval between hello packets sent to the  
root bridge.  
Auto detection of non-edge ports is not supported. A non-edge port is one that is connected directly to an  
end-user computer such as a PC or laptop.  
You can enable/disable RSTP on VLAN trunk ports only. By default, RSTP is disabled on trunk ports.  
Note You should enable the RSTP before performing physical network connectivity between the  
SonicWALL NSA 2400MX and another switch.  
When the SonicWALL NSA 2400MX is booting up, ports are disabled until Spanning Tree configuration is  
applied. The NSA 2400MX automatically soft-bridges the STP Bridge Protocol Data Units (BPDUs)  
between the ports to prevent loops when ports in the same VLAN (PortShield group or L2 Bridge mode)  
are connected to another switch. This allows the remote switch to detect that its ports are connected to  
another switch and it can automatically block certain ports.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuring Switching  
Figure 9 illustrates the possible loop that is logically blocked when ports in the same VLAN exist on multiple  
connected switches in a network.  
Figure 9  
RSTP on VLAN Trunk Ports Detects and Blocks Loops Between Switches  
Internet  
Network Security Appliance  
2400MX  
VLAN  
Trunk  
VLAN  
Trunk  
Loop  
Switch  
Switch  
X
Logically Blocked  
- with RSTP running  
on NSA and Switches  
Sales  
Sales  
Eng  
Eng  
You can view the port settings for RSTP-eligible interfaces on the Switching > Rapid Spanning Tree page.  
See Table 3 for an explanation of the port settings.  
Table 3  
Switching > Rapid Spanning Tree Port Settings  
Configurable  
Item  
Name  
Type  
Cost  
Description  
from this Page  
Indicates the interface number, such as X20.  
Indicates link status and speed.  
No  
No  
Displays the port cost. This can be a configured value or an Yes  
automatically calculated value based on link speed.  
Priority  
State  
Displays the port priority. This defaults to the interface  
number unless configured otherwise.  
Yes  
No  
No  
Yes  
Indicates whether the port is currently forwarding,  
discarding, or blocking packets.  
Role  
Indicates the role and status of the port, such as root,  
designated, alternate, backup, or disabled.  
Enabled  
Indicates whether or not RSTP (or STP) is enabled.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Configuring Switching  
Configuring Bridge Settings  
To configure the Bridge Settings on the Switching > Rapid Spanning Tree page, perform the following steps:  
Step 1 To specify the spanning tree protocol version to use, select one of the following from the Force Version  
drop-down list:  
RSTP Operation – Use Rapid Spanning Tree Protocol.  
STP Only – Use the original Spanning Tree Protocol.  
Step 2 To specify the priority of the root bridge, type the desired priority into the Bridge Priority field. Bridge  
priority is configurable in multiples of 4,096 with a default value of 32,768 and maximum of 61,440. Lower  
numbers indicate higher priority. Bridge priority is the key factor in determining the root bridge. It also  
determines the designated bridge for each LAN segment when multiple bridges have the same path cost to  
the root bridge.  
Step 3 To specify the Hello time, type the desired number of seconds to allow into the Hello Time (secs) field.  
The Hello time is the time interval between transmission of BPDUs by the root bridge and other  
bridges/switches in the network. The default is 3 and the range is 1 to 10 seconds. The Hello time is  
communicated to other switches by including it in the BPDU along with other topology information for the  
bridged LAN.  
Step 4 To specify the forward delay, type the desired number of seconds into the Forward Delay (secs) field. The  
forward delay is the time allowed for the listening and learning state. It is also the time that it takes to convert  
an interface from a blocking state to a forwarding state. The default is 15 and the range is 4 to 30 seconds.  
The forward delay setting is communicated to other switches by including it in the BPDU.  
Step 5 When finished, click Apply.  
Configuring Port Settings  
You can enable or disable RSTP and configure path cost and priority for each VLAN trunk port on your  
SonicWALL NSA 2400MX.  
When port settings have been specified for an interface, the Port Settings table on the Switching > Rapid  
Spanning Tree page contains a row for that interface. A Configure icon is enabled for it unless Link  
Aggregation is enabled for the interface.  
Note If you need to enable RSTP on interfaces in a link aggregation group, first enable RSTP on  
the individual ports and then enable link aggregation.  
To configure the Port Settings on the Switching > Rapid Spanning Tree page, perform the following steps:  
Step 1 Under Port Settings, click the Configure icon in the row for the interface you want to edit.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Configuring Switching  
Step 2 In the Edit RSTP Settings window, select the Enable RSTP checkbox to enable Rapid Spanning Tree  
Protocol for this interface. Clear the checkbox to disable RSTP on this interface.  
Step 3 To allow the path cost for the port to be automatically calculated by SonicOS, select the Auto checkbox.  
The Auto option is enabled by default. If left in auto-mode, the port cost is determined based on link speed.  
Step 4 To specify the path cost for the port, type the desired cost value into the Port Path Cost field. You can  
assign an arbitrary cost value or base the cost on guidelines provided by the RSTP or STP specification. The  
cost is higher for lower bandwidth connections. According to guidelines, the cost of a 1 Gbps bandwidth  
connection would be 2, compared to the cost of 19 for a 100 Mbps Fast Ethernet connection or 100 for a  
10 Mbps connection.  
Step 5 To specify the port priority, type the desired priority into the Port Priority field. The port priority defaults  
to the interface number unless configured otherwise. The range is 0 to 15. A lower number indicates higher  
priority. Port priority is important when multiple ports are connected to the same switch and there is a  
possible loop, or in the case where the cost of the path to the root bridge is the same as it is for another  
port. The port with the lower number for port priority is used to forward traffic. The port with the lower  
priority (indicated by a higher number) is blocked.  
Note The range for input into the Port Priority field is 0 to 15. The number you enter is  
automatically multiplied by 16 when applied.  
Configuring Layer 2 Discovery  
The Switching > Layer 2 Discovery page accesses information about switches and other devices in the  
network, using the Link Layer Discovery Protocol (LLDP). LLDP is a non-proprietary protocol used by  
network devices in the LAN to advertise their identity, capabilities, and interconnections. The LLDP  
protocol is defined by the IEEE 802.1AB standard, which is titled “Station and Media Access Control  
Connectivity Discovery.”  
In addition to LLDP, the SonicWALL NSA 2400MX uses Microsoft Link Layer Topology Discovery  
(LLTD) protocol to discover nodes visible from a port. Link Layer Topology Discovery (LLTD) is a  
Microsoft proprietary protocol with functionality similar to LLDP. It operates on wired or wireless networks  
(Ethernet 802.3 or wireless 802.11). LLTD is included on Windows Vista and Windows 7, and can be  
installed on Windows XP.  
Note Windows XP users need to download, install, and enable the LLTD responder driver from  
Microsoft.  
Both LLDP and LLTD are Layer 2 protocols and do not cross a broadcast domain. A switch forwarding  
table is also used during discovery, and an ARP table is used to connect MAC addresses to IP addresses.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuring Switching  
On many switches and network devices, the LLDP information is stored as a management information  
database (MIB). Simple Network Management Protocol (SNMP) is used to query the MIB for device  
information, including system name, port name, VLAN name, IP address, system capabilities (such as  
switching or routing), MAC address, and link aggregation settings. The topology of a network can be  
discovered by crawling the hosts and querying the MIB database on each.  
The LLDP transmitter is not implemented in SonicOS 5.7.0.0. The Switching > L2 Discovery page displays  
Layer 2 information obtained via LLDP from other, LLDP-enabled, switches and devices in the network.  
Figure 10 shows information obtained via discovery on the X1 (WAN) interface.  
Figure 10  
Switching > L2 Discovery Page  
The Switching > L2 Discovery feature does not proactively manage the discovery. Discovery is active when  
the system boots up and then does not restart unless you click the L2 Discovery refresh button  
SonicOS management interface.  
in the  
To restart Layer 2 discovery on multiple interfaces, you can select the checkbox next to the desired interfaces  
and then click the Refresh Selected button at the bottom of the page, as shown in Figure 11.  
Figure 11  
Restarting Layer 2 Discovery on Selected Interfaces  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Configuring Switching  
Viewing Device Information in the Layer 2 Discovery Page  
To view the LLDP/LLTD discovery results for your network, perform the following steps:  
Step 1 Enable LLDP on any switches or other network devices in your network, using a command such as “lldp  
run”. LLDP is usually not enabled by default.  
Step 2 To get LLTD results from Windows XP machines in your network, download, install, and enable the LLTD  
responder driver from Microsoft on those machines. LLTD is installed and enabled by default on Windows  
Vista and Windows 7 machines.  
Step 3 In the SonicOS management interface, navigate to the Switching > L2 Discovery page.  
Step 4 To view the LLDP/LLTD results for a single interface, click the Refresh  
button in the same row as the  
interface.  
Step 5 To view the LLDP/LLTD results for multiple interfaces, select the checkboxes for those interfaces and then  
click the Refresh Selected button at the bottom of the page. You can select all interfaces by selecting the  
checkbox next to Interface in the table heading.  
Figure 12 shows the LLDP discovery results for an HP ProCurve switch and a Cisco switch (both circled in  
red). The other details are the LLTD results.  
Figure 12  
Switch Information in the Switching > Layer 2 Discovery Page  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuring Switching  
Configuring Link Aggregation  
SonicOS 5.7 supports the IEEE 802.1AX-2008 Link Aggregation Control Protocol (LACP). LACP is used  
when multiple network ports are connected in parallel between two switches or between a switch and a  
server. Link aggregation makes it possible to increase the bandwidth beyond the limits of a single  
connection, and to provide seamless, higher availability by creating a redundant link.  
Link aggregation in SonicOS 5.7 allows port redundancy and load balancing in Layer 2 networks. Load  
balancing is controlled by the hardware, based on source and destination MAC address pairs. The Switching  
> Link Aggregation page provides information and statistics, and allows configuration of interfaces for  
aggregation.  
Figure 13 shows the Switching > Link Aggregation page in the SonicOS user interface.  
Figure 13  
Switching > Link Aggregation Page  
Static and Dynamic Link Aggregation are supported. Dynamic Link Aggregation is supported with the use  
of LACP (IEEE 802.1AX). Ports that are in the same VLAN (same PortShield Group) or are VLAN trunk  
ports are eligible for link aggregation. Up to four ports can be aggregated in a logical group called a Logical  
Link, and there can be four Logical Links configured.  
Two main types of usage are enabled by this feature:  
SonicWALL NSA 2400MX to Server – This is implemented by enabling link aggregation on ports  
within the same VLAN (same PortShield Group). This configuration allows port redundancy, but does  
not support load balancing in the NSA 2400MX-to-Server direction due to a hardware limitation on the  
NSA 2400MX.  
SonicWALL NSA 2400MX to Switch – This is allowed by enabling link aggregation on VLAN trunk  
ports. Load balancing is automatically performed by the hardware. The NSA 2400MX supports one  
load balancing algorithm based on source and destination MAC address pairs.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Configuring Switching  
Figure 14 illustrates the two types of link aggregation.  
Figure 14  
Two Types of Link Aggregation: NSA to Server and NSA to Switch  
Server  
Logical Link  
Redundant - Not Load Balanced  
Network Security Appliance  
2400MX  
Logical Link  
Redundant and Load Balanced  
Internet  
Switch  
Eng  
QA  
VLAN  
VLAN  
Similarly to PortShield configuration, you select an interface that represents the aggregated group. This port  
is called an aggregator. The aggregator port must be assigned a unique key. By default, the aggregator port  
key is the same as its interface number. Non-aggregator ports can be optionally configured with a key, which  
can help prevent an erroneous Logical Link if the switch connections are wired incorrectly.  
Ports bond together if connected to the same link partner and their keys match. If there is no key configured  
for a port (if the port is in auto mode), it will bond with an aggregator that is connected to the same link  
partner. The link partner is discovered via LACP messages. A link partner cannot be discovered for Static  
link aggregation. In this case, ports aggregate based on keys alone.  
Like a PortShield host, the aggregator port cannot be removed from the Logical Link since it represents the  
Logical Link in the system.  
Note Once link aggregation has been enabled on VLAN trunk ports, additional VLANs cannot be  
added or deleted on the Logical Link.  
Note If you need to enable RSTP on the Logical Link, first enable RSTP on the individual  
members and then enable link aggregation.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuring Switching  
Creating a Logical Link  
To create a Logical Link, perform the following steps:  
Step 1 On the Switching > Link Aggregation page, click the Add button.  
Step 2 In the Add LAG Port window, select the interface from the Port drop-down list.  
Step 3 To specify a key, clear the Auto-Detect checkbox and type the desired key into the Key field.  
Step 4 If this interface will be the aggregator for the Logical Link, select the Aggregator checkbox. Only one  
interface can be an aggregator for a Logical Link.  
Step 5 To enable LACP, select the LACP Enable checkbox. Dynamic Link Aggregation is supported with the use  
of LACP. The link partner is discovered via LACP messages.  
Step 6 Click OK.  
Step 7 On the Switching > Link Aggregation page, click the Add button again.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuring Switching  
Step 8 In the Add LAG Port window, select the interface for the link partner from the Port drop-down list.  
Step 9 If you specified a key for the first interface (the aggregator), clear the Auto-Detect checkbox and type the  
same key into the Key field. If Auto-Detect was left enabled for the first interface, leave it enabled for this  
one as well.  
Step 10 Clear the Aggregator checkbox. Only one interface can be an aggregator for a Logical Link.  
Step 11 Select the LACP Enable checkbox. This is necessary to create the Logical Link.  
Step 12 Click OK.  
The Switching > Link Aggregation page displays the Logical Link. The Partner column will display the  
MAC addresses of the link partners after they are physically connected.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuring Switching  
Configuring Port Mirroring  
You can configure Port Mirroring on the SonicWALL NSA 2400MX to send a copy of network packets seen  
on one or more switch ports (or on a VLAN) to another switch port called the mirror port. By connecting  
to the mirror port, you can monitor the traffic passing through the mirrored port(s).  
Figure 15 shows the Switching > Port Mirroring page with one mirror group configured. Traffic on interface  
X20 is being mirrored to interface X22, the designated mirror port.  
Figure 15  
Switching > Port Mirroring Page  
A VLAN trunk port can be mirrored, but cannot act as a mirror port itself. VLAN trunk ports are used to pass  
traffic to other networking devices. By comparison, traffic arriving on a mirror port has already been handled or  
sent to its destination, and the mirror port does not forward it again. Typically, the traffic is passed from the mirror  
port to a computer where the administrator can use an application, such as Wireshark, to view the traffic content.  
The Switching > Port Mirroring page allows the administrator to assign mirror ports to mirror ingress,  
egress or bidirectional packets coming from a group of ports.  
See the following procedures:  
Configuring a Port Mirroring Group  
To create a new port mirroring group, perform the following steps:  
Step 1 On the Switching > Port Mirroring page, click the New Group button.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
Download from Www.Somanuals.com. All Manuals Search And Download.  
25  
     
Configuring Switching  
Step 2 In the Edit Mirror Group window, type a descriptive name for the group into the Interface Group Name  
field.  
Step 3 For the Direction, select one of the following:  
ingress – Select ingress to monitor traffic arriving on the mirrored port(s).  
egress – Select egress to monitor traffic being sent out on the mirrored port(s).  
both – Select both to monitor traffic in both directions on the mirrored port(s).  
Step 4 In the All Interfaces list, select the port to mirror the traffic to and click the top right-arrow button to move  
it to the Mirror Port field. You must use an unassigned port as the mirror port.  
Step 5 In the All Interfaces list, select one or more ports to be monitored, and click the lower right-arrow button  
to move it/them to the Mirrored Ports field. You will be able to monitor traffic on the mirrored port(s) by  
connecting to the mirror port.  
Step 6 Click OK.  
Step 7 To begin copying network packets from the Mirrored Ports to the Mirror Port, select the Enable checkbox  
in the Switching > Port Mirroring page.  
Step 8 Click OK.  
Deleting a Port Mirroring Group  
To remove a port mirroring group, perform the following steps:  
Step 1 On the Switching > Port Mirroring page, select the checkbox next to the port mirroring group that you want  
to delete.  
Step 2 Click the Ungroup button.  
Step 3 Click OK in the confirmation dialog box.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuring Switching  
Configuring Layer 2 Quality of Service  
Quality of service (QoS) refers to a method of resource control that provides different priority to different  
types of applications, data, or users. QoS can also be used to guarantee a certain bit rate, delay, jitter, or error  
rate to a type of network traffic. When network capacity is not large enough to accommodate all traffic at  
full speed, QoS performance guarantees are essential in the delivery of delay senistive applications such as  
Voice over IP (VoIP), online gaming, and Internet TV.  
Layer 2, or Ethernet, QoS, provided by SonicOS 5.7 on the SonicWALL NSA 2400MX, is appropriate for  
real-time streaming multimedia applications such as those mentioned above. At Layer 2, VLANs may also  
be used to separate traffic of different QoS levels (VLAN tagging is defined in IEEE 802.1Q).  
SonicOS Layer 2 QoS supports Class of Service (CoS) as specified in IEEE 802.1p. CoS uses a 3 bit field  
within the Ethernet frame header. It provides 8 levels of priority for use with QoS algorithms to handle  
different types of traffic.  
SonicOS also supports Differentiated Services Code Point (DSCP). Also known as Differentiated Services  
or DiffServ, DSCP uses a 6-bit field in the header of IP packets (Layer 3) for packet classification, and  
provides a simple method of providing QoS guaranteed service to voice or video while using best-effort for  
traffic that is not delay sensitive. Best -effort service is the default for most Internet traffic and does not  
provide any guarantees.  
The SonicWALL NSA 2400MX appliance can be configured to trust Class of Service (CoS) (IEEE 802.1p)  
and/or trust Differentiated Services Code Point (DSCP) per port and treat the frames appropriately.  
The Switching > Layer 2 QoS page allows the administrator to configure QoS settings per interface.  
Figure 16 shows the Switching > Layer 2 Qos page.  
Figure 16  
Switching > Layer 2 QoS Page  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
Download from Www.Somanuals.com. All Manuals Search And Download.  
27  
   
Configuring Switching  
In SonicOS, four queues with different priority levels (low, normal, high, highest) are supported. These are  
mapped to the eight levels defined in IEEE 802.1p (CoS) and cannot be changed. Table 4 shows the  
mapping between the CoS priority levels and the four supported queue priority levels.  
Table 4  
802.1p Priority Levels Mapped to Four Queues  
CoS Priority  
Traffic Type  
Best Effort  
Queue Priority  
Normal  
Low  
0
1
2
3
Background  
Spare  
Low  
Excellent Effort (Business Normal  
critical)  
4
5
Controlled Load (Streaming High  
multimedia)  
Video (Interactive Media)  
[Less than 100ms latency  
and jitter]  
High  
6
7
Voice [Less than 10ms  
latency and jitter]  
Highest  
Highest  
Network Control [Lowest  
latency and jitter]  
On the Switching > Layer 2 QoS page, you can configure the mapping between each value in the DSCP  
range of 0-63 and the four queues (Low, Normal, High, Highest) supported for Layer 2 QoS, or reset the  
entire map to the default settings (Normal queue for all DSCP values). Also, on the Firewall > QoS Mapping  
page, you can configure the mapping between the DSCP range and the 8 levels defined by CoS.  
Frames received on ports configured to trust CoS or DSCP are queued appropriately according to the  
mapping table. An option is provided to select the field to use when both the 802.1p tag field and the DSCP  
field are present in ingressing frames.  
For QoS settings, ports can be assigned a default priority. The default priority is used when Trust CoS or  
Trust DSCP is enabled, but the information is absent. When Fixed Priority is enabled, the 802.1p tag field  
and DSCP field are ignored and the default priority is used.  
See the following procedures:  
Configuring the Scheduling Mechanism  
To configure Weighted Round-Robin or Strict Priority Queue as the output scheduling mechanism, perform  
the following steps:  
Step 1 On the Switching > Layer 2 QoS page, select one of the following from the Output Scheduling  
Mechanism drop-down list:  
Weighted Round-Robin – When Weighted Round-Robin is selected, the weighting factors are 8:4:2:1.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Configuring Switching  
Strict Priority Queue – When Strict Priority Queue is selected, packets containing an 802.1p tag or  
DSCP marking with a priority level matching the Highest queue priority are forwarded or received.  
Packets matching High, Normal or Low priority may be dropped.  
Step 2 Click the Apply button.  
Configuring DSCP Mapping  
You can configure the DSCP mapping by setting the priority levels for DSCP values 0 through 63. The  
Switching > Layer 2 QoS page also provides a Reset DSCP Remap button to reset the priority levels back  
to the default, which is “Normal.”  
To configure DSCP mapping, perform the following steps:  
Step 1 To show the DSCP Remap table, click Hide/Show next to the DSCP Remap Table heading. The priority  
settings for all DSCP values, 0 - 63, are displayed.  
Step 2 For each DSCP value (0 - 63) that you want to change, select one of the following from the Priority  
drop-down list:  
Low  
Normal  
High  
Highest  
Step 3 Click the Apply button. The DSCP Remap table is hidden, but if you show it again you will see the updated  
priority settings.  
Step 4 To reset all DSCP mapping back to the default, Normal, click the Reset DSCP Remap button and then  
click OK in the confirmation dialog box.  
Showing the CoS Remap Table  
To show the CoS Remap table, click Hide/Show next to the CoS Remap Table heading. The priority levels  
cannot be configured. The CoS Remap table is shown in Figure 17.  
Figure 17  
Showing the CoS Remap Table on the Switching > Layer 2 QoS Page  
To hide the CoS Remap table, click Hide/Show next to the CoS Remap Table heading again.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Configuring Switching  
Configuring QoS Settings  
The QoS Settings table on the Switching > Layer 2 QoS page lists all interfaces on the SonicWALL NSA  
2400MX. You can configure the QoS settings for each interface individually or for multiple interfaces at the  
same time. A portion of the QoS Settings table is shown in Figure 18.  
Figure 18  
QoS Settings Table on the Switching > Layer 2 QoS Page  
See the following procedures:  
Configuring QoS Settings for an Individual Interface  
To configure QoS settings for frames received on an individual interface, perform the following steps:  
Step 1 On the Switching > Layer 2 QoS page under QoS Settings, click the Configure icon in the row for the  
interface you want to configure. The Edit QoS Settings window opens.  
Step 2 In the Edit QoS Settings window, to enable fixed priority for frames arriving on this interface, select the  
Fixed Priority checkbox. When Fixed Priority is selected, the remaining checkboxes are cleared and  
disabled (greyed out). The CoS 802.1p tag field and DSCP field are ignored and the ingress port’s default  
priority is always used.  
Step 3 To enable the use of the CoS 802.1p tag field settings for Quality of Service on this interface, select the  
Trust CoS checkbox. The Fixed Priority checkbox must be cleared before you can select any other  
checkbox.  
Step 4 To enable the use of the DSCP field settings for Quality of Service on this interface, select the Trust DSCP  
checkbox. The Fixed Priority checkbox must be cleared before you can select any other checkbox.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Configuring Switching  
Step 5 If both Trust CoS and Trust DSCP are selected, do one of the following:  
Select the Prefer CoS checkbox to give preference to the CoS 802.1p tag field settings when both the  
802.1p tag field and the DSCP field are present in ingressing frames.  
Clear the Prefer CoS checkbox to give preference to the DSCP field settings when both the 802.1p tag  
field and the DSCP field are present in ingressing frames.  
Step 6 Select one of the following priority levels from the Default Priority drop-down list:  
Low  
Normal  
High  
Highest  
If ingressing frames do not contain either a CoS 802.1p tag field or a DSCP field, the default priority is used.  
Step 7 Click OK.  
Configuring QoS Settings for Multiple Interfaces  
To configure QoS settings for frames received on any of several interfaces, perform the following steps:  
Step 1 On the Switching > Layer 2 QoS page under QoS Settings, select the checkboxes next to the interfaces you  
want to configure, and then click the Configure button at the bottom of the page. The Edit QoS Settings  
window opens.  
Step 2 The Keep original QoS mode of each port checkbox is selected by default. When this checkbox is  
selected, each individual port’s QoS mode remains unchanged, and only the Default Priority setting is  
changed to the configured value (Step 7) for each port being configured.  
To activate the other checkboxes in this window and make changes to the QoS settings of the selected  
interfaces, clear the Keep original QoS mode of each port checkbox.  
Step 3 To enable fixed priority for frames arriving on these interfaces, select the Fixed Priority checkbox. When  
Fixed Priority is selected, the subsequent checkboxes are cleared and disabled (greyed out). The CoS 802.1p  
tag field and DSCP field are ignored and the ingress port’s default priority is always used.  
Step 4 To enable the use of the CoS 802.1p tag field settings for Quality of Service on these interfaces, select the  
Trust CoS checkbox. The Fixed Priority checkbox must be cleared before you can select this checkbox.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuring Switching  
Step 5 To enable the use of the DSCP field settings for Quality of Service on these interfaces, select the Trust  
DSCP checkbox. The Fixed Priority checkbox must be cleared before you can select this checkbox.  
Step 6 If both Trust CoS and Trust DSCP are selected, do one of the following:  
Select the Prefer CoS checkbox to give preference to the CoS 802.1p tag field settings when both the  
802.1p tag field and the DSCP field are present in ingressing frames.  
Clear the Prefer CoS checkbox to give preference to the DSCP field settings when both the 802.1p tag  
field and the DSCP field are present in ingressing frames.  
Step 7 Select one of the following priority levels from the Default Priority drop-down list:  
Keep Original Settings – Choose this setting to allow each interface to default to its original individual  
QoS settings.  
Low  
Normal  
High  
Highest  
If ingressing frames do not contain either a CoS 802.1p tag field or a DSCP field, the default priority is used.  
Step 8 Click OK.  
Configuring Rate Control  
SonicOS supports per-interface rate limiting and flow control on the Switching > Rate Control page.  
Rate limiting provides a way to control the rate of traffic sent or received on a network interface. Traffic is  
sent or received while its rate is less than or equal to the specified rate limit , while traffic that exceeds the  
rate is dropped or delayed.  
Flow control allows you to manage the rate of data transmission between two devices to prevent a fast  
sender from getting too far ahead of a slow receiver. Flow control provides a mechanism for the receiver to  
control the transmission speed to avoid being overwhelmed with data from the sender. Flow control is  
important in cases where the receiver has a heavy load to process compared to the sender, or if the receiver  
is a slower computer than the sender.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Configuring Switching  
The Switching > Rate Control page, shown in Figure 19, provides information and configuration for  
per-interface rate limiting and flow control. Both the rate limiting and flow control features are configured  
on a per port basis.  
Figure 19  
Switching > Rate Control Page  
Egress Traffic Rate Limiting  
In SonicOS, the rate limiting for egress frames can only be enabled or disabled, no mode can be selected.  
Ingress Traffic Rate Limiting  
In SonicOS, the bandwidth of ingress frames can be rate-limited in four modes:  
Limit All Frames – Apply rate limiting to all types of network traffic arriving on the interface  
Limit just broadcast, multicast and flooded unicast frames – Apply rate limiting to broadcast, multicast  
and flooded unicast traffic arriving on the interface, where:  
Broadcast traffic is traffic that is simultaneously sent to all computers in the network, typically to  
announce shared services and state information.  
Multicast traffic is traffic that is simultaneously sent to a group of computers in the network.  
Specific multicast addresses are used for different purposes. For example, Spanning Tree Protocol  
802.1D for bridges uses the well-known multicast address 01-80-C2-00-00-00, and Spanning Tree  
Protocol 802.1AD for provider bridges uses the well-known multicast address 01-80-C2-00-00-08.  
Flooded unicast traffic is traffic that is sent by a switch to all the interfaces in the VLAN. This can  
occur if the destination MAC address for a frame has not yet been learned by the switch, making  
it an unknown unicast.  
Limit just broadcast and multicast frames – Apply rate limiting to broadcast and multicast traffic  
arriving on the interface  
Limit just broadcast frames – Apply rate limiting to broadcast traffic arriving on the interface  
The ingress rate limit is rounded to the nearest increment, depending on the the granularity available for  
that rate. The granularities are different depending on the range of rates:  
128kbps ~ 1Mbps – increments of 64kbps  
1Mbps ~ 100Mbps – increments of 1Mbps  
100Mbps ~ 1000Mbps – increments of 10Mbps (for gigabit ports)  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
Download from Www.Somanuals.com. All Manuals Search And Download.  
33  
 
Configuring Switching  
Flow Control  
In SonicOS, back-pressure flow control on half-duplex ports and pause frame-based flow control on  
full-duplex ports are provided to support zero packet loss under temporary traffic congestion.  
Full-duplex flow control requires support from the peer end station. Full-duplex flow control works as  
follows: when a port’s free buffer space is almost empty, the devices send out a PAUSE frame with the  
maximum pause time to stop the remote node from sending more frames into the switch. The devices  
also respond to the pause command. Once the PAUSE frame is detected, the port will stop transmission  
of new data for the amount of time defined in the pause time field of the received PAUSE frame.  
Half-duplex flow control is used to throttle the throughput rate of an end station to avoid dropping  
packets during network congestion.  
Configuring Rate Control Settings for an Interface  
To configure rate control settings or to enable flow control, perform the following steps:  
Step 1 On the Switching > Rate Control page, click the Configure icon in the row for the interface you want to  
configure. The Edit Rate Control Settings window opens.  
Step 2 To enable flow control on this interface, select the Enable Flow Control checkbox.  
Step 3 To set the mode for limiting the bandwidth of ingressing frames, select one of the following from the  
Ingress Mode drop-down list:  
Limit All – Apply rate limiting to all types of network traffic arriving on the interface  
Limit Broadcast, Multicast and Flooded Unicast – Apply rate limiting to broadcast, multicast and  
flooded unicast traffic arriving on the interface  
Limit Broadcast and Multicast – Apply rate limiting to broadcast and multicast traffic arriving on the  
interface, where:  
Broadcast traffic is traffic that is simultaneously sent to all computers in the network, typically to  
announce shared services and state information.  
Multicast traffic is traffic that is simultaneously sent to a group of computers in the network.  
Specific multicast addresses are used for different purposes. For example, Spanning Tree Protocol  
802.1D for bridges uses the well-known multicast address 01-80-C2-00-00-00, and Spanning Tree  
Protocol 802.1AD for provider bridges uses the well-known multicast address 01-80-C2-00-00-08.  
Flooded unicast traffic is traffic that is sent by a switch to all the interfaces in the VLAN. This can  
occur if the destination MAC address for a frame has not yet been learned by the switch, making  
it an unknown unicast.  
Limit Only Broadcast – Apply rate limiting to broadcast arriving on the interface  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuring Switching  
Step 4 Type the desired ingress rate limit in kilobits per second into the Ingress Rate field. To turn off the ingress  
rate limit and allow unlimited traffic, type 0 (zero). The value you type will be rounded to the nearest  
increment, depending on the the granularity available for that rate. The granularities are different depending  
on the range of rates:  
128kbps ~ 1Mbps – increments of 64kbps  
1Mbps ~ 100Mbps – increments of 1Mbps  
100Mbps ~ 1000Mbps – increments of 10Mbps (for gigabit ports)  
Step 5 Type the desired egress rate limit in kilobits per second into the Egress Rate field. To turn off the egress  
rate limit and allow unlimited traffic, type 0 (zero). The value you type will be rounded to the nearest  
increment, depending on the the granularity available for that rate. The granularities are the same as for the  
ingress rate.  
Step 6 Click OK.  
Configuring Port Security  
On the Switching > Port Security page, each port can be configured to enable or disable the Discard  
Tagged option. When it is enabled, all frames with a 802.3ac tag (or “Q-tag”) are discarded. IEEE 802.3ac  
specifies an extension of 4 bytes to the Ethernet frame size, allowing 1522 bytes per frame. The additional  
4 bytes are for the “Q-tag”, which includes 802.1Q VLAN information and 802.1p priority information.  
A secure port is meant to receive untagged frames. If a frame has a tag, even when its Security Association  
(SA) is trusted, it will be discarded.  
Only static port security is supported. This means that the SonicWALL NSA 2400MX administrator must  
create MAC address objects for the trusted MAC addresses and bind the MAC address objects to specific  
ports. Frames whose source addresses are not contained in the table will be dropped.  
MAC address objects are one type of address object in SonicOS. Address objects allow for entities to be  
defined one time and then re-used in multiple referential instances throughout the SonicOS interface.  
Address objects can be selected from a drop-down menu in many configuration screens throughout the user  
interface.  
A VLAN trunk port or a port currently configured for link aggregation as part of a Logical Link cannot be  
a secure port at the same time. This prevents a non-trunk port from connecting to a trunk port.  
Figure 20 shows part of the Switching > Port Security page, with one secure port configured.  
Figure 20  
Switching > Port Security Page  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Configuring Switching  
See the following procedures for information about configuring port security:  
Creating a Secure Port by Adding a MAC Address Object  
To configure port security, you must use an address object to bind MAC address(es) to an interface. You can  
create an address object from within the procedure described below, or use an existing one. For more  
information about address objects, see the SonicOS 5.7 Administrator’s Guide.  
To create a secure port by adding a MAC address object to an interface, perform the following steps:  
Step 1 On the Switching > Port Security page, click the Add button at the bottom of the page. The Add Static MAC  
Address window opens.  
Step 2 Select the desired interface from the Port drop-down list. This will be the secure port.  
Step 3 If the address object that contains the desired MAC addresses already exists, select it from the MAC  
Address drop-down list and skip to Step 10.  
Step 4 To create a MAC address object, select Create new address object from the MAC Address drop-down  
list. The Add Address Object window opens.  
Note Turn off the pop-up blocker in your browser before selecting Create new address object.  
Step 5 Type a descriptive name for the address object into the Name field.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Configuring Switching  
Step 6 Select the zone from the Zone Assignment drop-down list. This is the zone for the computer with this  
MAC address. You can select any zone that exists on the SonicWALL NSA 2400MX, including custom zones  
and the SonicOS default zones, which are LAN, WAN, DMZ, VPN, SSLVPN, MULTICAST, and WLAN.  
Step 7 The only available selection for Type is MAC, indicating that you are creating a MAC Address Object.  
Step 8 If the device with this MAC address can have multiple IP addresses, select the Multi-homed host checkbox.  
Otherwise, clear this checkbox.  
Step 9 Click OK in the Add Address Object window. The new address object appears in the MAC Address field  
of the Add Static MAC Address window.  
Step 10 Click OK in the Add Static MAC Address window to complete the secure port configuration using these  
settings.  
Editing MAC Address Objects in Port Security Settings  
To edit a MAC address object for a secure port on the Switching > Port Security page, perform the following  
steps:  
Step 1 Click the Configure icon in the row for the MAC address object you want to edit. The Edit Static MAC  
Address window opens.  
Step 2 Select a different address object or select Create new address object from the MAC Address drop-down  
list and follow the steps provided in Step 4 through Step 9 of the “Creating a Secure Port by Adding a MAC  
Step 3 When finished, click OK.  
Deleting MAC Address Objects from Port Security Settings  
To delete one or more MAC address objects from your secure port settings on the Switching > Port Security  
page, perform the following steps:  
Step 1 To delete a single MAC address object, click the Delete icon  
in the Configure column for the row with  
the MAC address object you want to delete.  
Step 2 To delete multiple MAC address objects, select the checkboxes next to the MAC address objects you want  
to delete and then click the Delete Selected button at the bottom of the page.  
Step 3 Click OK in the confirmation dialog box.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Troubleshooting and Verification  
Troubleshooting and Verification  
This section provides methods you can use to verify and troubleshoot the behavior of your Switching  
configuration.  
See the following sections:  
Using Port Mirroring with Wireshark  
Because switched frames cannot be viewed with SonicOS Packet Monitoring, configuring Port Mirroring  
and viewing the mirrored traffic with a network analyzer is the preferred method for examining traffic as it  
passes through the appliance interfaces. When using Packet Monitoring, the packets are displayed in the  
SonicOS user interface. However, with Port Mirroring, the mirrored traffic is sent to a port rather than to  
the user interface. A computer running a network analyzer, such as Wireshark, is connected to the mirror  
port and the network analyzer is used to display the mirrored traffic.  
This section describes an example situation where two VLAN Trunk ports are mirrored to a port that is  
connected to a computer running Wireshark. The two trunk ports are enabled for Rapid Spanning Tree and  
Link Aggregation, and the RSTP and LACP Layer 2 frames can be seen in Wireshark.  
Configuring Ports for Mirroring  
In this use case, the VLAN Trunk ports that we want to mirror are gigabit Ethernet ports. Therefore, we  
select a gigabit port as the Mirror Port.  
To configure Port Mirroring for this use case, perform the following steps:  
Step 1 On the Switching > Port Mirroring page, click the New Group button to open the Edit Mirror Group  
window.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Troubleshooting and Verification  
Step 2 In the Edit Mirror Group window, type a name for the Mirror Group.  
Step 3 For Direction, select both. This allows mirroring of traffic arriving on, and being transmitted from, the  
mirrored ports.  
Step 4 In the All Interfaces box, scroll down and select a gigabit interface for the Mirror Port. The selected  
interface must have an Unassigned zone. You can verify this on the Network > Interfaces page.  
Step 5 Click the right arrow button to movethe selected interface to the Mirror Port field. In this case, we select  
X20 as the Mirror Port.  
Step 6 In the All Interfaces box, scroll down and select the interfaces that you want to mirror. We select X24 and  
X25. These gigabit interfaces are enabled for RSTP and are configured as a Logical Link with X24 as the  
aggregator.  
Step 7 Click the right arrow button to movethe selected interfaces to the Mirrored Ports field.  
Step 8 Click OK.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting and Verification  
The X20, X24, and X25 interfaces are shown below on the Network > Interfaces page. You can see that all  
three are gigabit Ethernet ports, that the Zone for X20 is Unassigned and it is configured as a Mirror Port,  
and that X24 and X25 are configured as VLAN Trunk ports. X25 is marked as a member of a Logical Link.  
Using Wireshark  
Wireshark is a popular, open source network analysis tool that runs on Windows or Mac OS X computers.  
It allows you to analyze network traffic at the frame or packet level. You can download Wireshark for free  
To use Wireshark to view the mirrored packets from the SonicWALL NSA 2400MX:  
Step 1 Connect the SonicWALL NSA 2400MX port X20 to a gigabit Ethernet interface on your Wireshark  
computer.  
Step 2 To view only Layer 2 traffic in Wireshark, open Network Connections on the computer and right-click the  
gigabit interface you are using.  
Step 3 Select Properties in the drop-down list.  
Step 4 Clear the checkboxes for IPv4 and IPv6 traffic.  
Step 5 Click OK.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting and Verification  
Step 6 Launch Wireshark.  
Step 7 Do one of the following:  
Click the Start Capture button in the upper left corner, and then, in the dialog box, select the Start  
checkbox for the gigabit interface connected to the Mirror Port.  
Under Start capture on interface, click the link for the interface connected to the Mirror Port.  
Step 8 View the frames in the Wireshark main window.  
Step 9 When finished, click the Stop Capture button.  
Step 10 Optionally save the output as a .cap or .pcap file, by selecting File > Save as, choosing a location, and  
entering a file name.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting and Verification  
Viewing Log Event Messages for Switching  
A new log event, logstrAdvSwitch, is introduced in SonicOS 5.7 to address SonicOS Switching activities.  
It falls under a new category, Advanced Switching, which can only be seen on devices with the switching  
hardware, such as the SonicWALL NSA 2400MX. Other SonicWALL appliances will not show the new  
category, as it is not applicable to the hardware.  
You can filter the log for the Advanced Switching category to display only the log events related to switching.  
All messages are informational, and no actions are required by the administrator when these log messages  
occur.  
Table 5 describes the various instances of the logstrAdvSwitch log event specific to Switching in SonicOS  
5.7.  
Table 5  
Switching Log Event Messages  
Log Event Message  
Comments  
User configuration of Flow Control on an interface can cause the following log events:  
Flow control on X%d is enabled  
Flow control on X%d is disabled  
Where %d is a decimal number in the  
interface name. For example, X%d could  
be X3, X22, etc.  
User configuration of Rate Limiting on an interface can cause the following log events:  
Ingress rate on X%d is limited to x kbps  
Ingress rate on X%d is not limited  
Egress rate on X%d is limited to x kbps  
Egress rate on X%d is not limited  
Where %d is a decimal number in the  
interface name. For example, X%d could  
be X3, X22, etc.  
Where x kbps is the number of kilobits  
per second for the limit.  
Ingress Rate limiting mode on X%d : Limit  
All  
Ingress Rate limiting mode on X%d : Limit  
Broadcast, Multicast and Flooded Unicast  
Ingress Rate limiting mode on X%d : Limit  
Broadcast and Multicast  
Ingress Rate limiting mode on X%d : Limit  
Only Broadcast  
User configuration of QoS Priority or Rules on an interface can cause the following log events:  
Default QoS Priority on X%d : x  
Desired QoS Rule on X%d : Trust CoS  
Desired QoS Rule on X%d : Trust DSCP  
Where x is the number for the priority  
level, with possible values of 0-7. See  
Table 4 on page 28 for a mapping of  
802.1p priority levels to the four priority  
queues supported by the SonicOS  
Switching feature.  
Desired QoS Rule on X%d : Both CoS and  
DSCP (Prefer DSCP)  
Desired QoS Rule on X%d : Both CoS and  
DSCP (Prefer CoS)  
CoS is Class of Service, IEEE 802.1p  
DSCP is Differentiated Services Code  
Point  
The following message is generated when the hardware determines that both ends of an  
Ethernet link support flow control and flow control will take effect as needed. the link Xi (e.g X0,  
X1, X2):  
Flow control on X%d is activated  
Where X%d indicates the link interface,  
such as X3.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
Download from Www.Somanuals.com. All Manuals Search And Download.  
42  
   
Troubleshooting and Verification  
Filtering the Log for Switching Events  
To display only the log events related to switching, perform the following steps:  
Step 1 Navigate to the Log > View page in the SonicOS management interface.  
Step 2 In the Log View Settings section, select Advanced Switching from the Category drop-down list.  
Step 3 Optionally select specific interfaces from the Source and/or Destination drop-down lists.  
The fields for which you select values into are combined into a search string with a logical AND. For  
example, if you select an interface for Source and for Destination, the search string will look for log events  
matching:  
Source interface AND Destination interface  
Note Do not enter IP addresses for Source or Destination, as these are not used in the Layer 2  
Advanced Switching log event messages.  
Step 4 Select the Group Filters checkbox next to any two or more criteria to combine them with a logical OR.  
Step 5 For example, if you select interfaces for Source and Destination, and select Advanced Switching for  
Category, and then select the Group Filters checkboxes next to Source and Destination, the search string  
will look for log event messages matching:  
(Source interface OR Destination interface) AND Advanced Switching category  
Step 6 Click Apply Filters to apply the filter immediately to the Log View table of event messages. Click Reset  
Filters to clear the filter and display the unfiltered results again.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Technical FAQ  
Technical FAQ  
How do I view the CAM table on the SonicWALL NSA 2400MX?  
The SonicOS 5.7.0.0 user interface or CLI does not provide a way to display the CAM, or MAC Address,  
table directly, but provides the same information in the ARP table and on the Switching > L2 Discovery  
page.  
A Content Addressable Memory (CAM) table is a dynamic, internal, purely Layer 2 mapping between switch  
ports and the MAC addresses that are bound to them. The CAM table information is also referred to as the  
MAC address table, switching cache, or forwarding data. The CAM table is used to quickly dereference MAC  
addresses to the switch ports where they are connected, allowing the speedy switching of traffic out the port  
to the destination. The CAM table is populated when the switch receives a data frame on one of its ports  
and updates the table with the frame's source MAC address and the port on which it was received.  
In SonicOS 5.7.0.0, the information displayed on the the Switching > L2 Discovery page is derived from  
three sources:  
MAC address table, internal to the switch (SonicWALL NSA 2400MX)  
ARP table maintained by the gateway  
Layer 2 Discovery Protocol exchanges  
To illustrate the difference between the MAC address table and the ARP table, consider a situation where  
you have two computers that use static IP addresses and communicate with each other within the same  
VLAN. The traffic between them never reaches the IP layer (the traffic is never forwarded, always  
switched).  
These machines will only show up in the MAC address table of the switch. The Switching > L2 Discovery  
page will display the MAC addresses and VLAN for these computers, but nothing else (assuming there is no  
discovery protocol agent running on these machines).  
If the machines stop communicating for awhile, the switch ages out the MAC address table and the entries  
will be gone. If you refresh the Switching > L2 Discovery page, you will no longer see these entries.  
On the other hand, if the machines connect to the Internet or to another VLAN, the traffic will be  
forwarded and the gateway ARP table is populated with entries for these computers. It is possible for entries  
to exist only in the gateway ARP table, but not in the switch MAC address table.  
The Switching > L2 Discovery page consolidates entries from the MAC address table and the ARP table,  
and displays one entry per machine.  
Many switches, such as the HP ProCurve, Dell PowerConnect, or Cisco switches, provide a command to  
display the CAM or MAC Address table. For example, the following output is from a Cisco switch running  
IOS:  
Cisco_L3# show mac-address-table dynamic  
Mac Address Table  
-------------------------------------------  
Vlan  
----  
Mac Address  
-----------  
0017.c52e.59ba  
0017.c52e.5aa4  
0017.c53c.d425  
Type  
Ports  
-----  
Fa0/3  
Fa0/4  
Po1  
--------  
DYNAMIC  
DYNAMIC  
DYNAMIC  
1
1
1
Total Mac Addresses for this criterion: 3  
Cisco_L3#  
The display shows two dynamic entries for SonicPoint-Ns, connected to switch ports 3 and 4 of the Cisco  
switch, and one entry for the LACP Link Aggregation Group, which is connected to a SonicWALL NSA  
2400MX and is not blocked by RSTP.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Glossary  
Glossary  
BPDU  
bridge  
Bridge Protocol Data Unit – Used in RSTP, BPDUs are special data frames used to  
exchange information about bridge IDs and root path costs. BPDUs are exchanged  
every few seconds to allow switches to keep track of network topology and start or stop  
port forwarding.  
A bridge is a data communications device that connects two Ethernet segments of a  
network together. A bridge operates by forwarding packets according to the destination  
Ethernet, or MAC, address, rather than by IP address. Because a bridge uses Layer 2, the  
data link layer, all protocols can be handled. Switches operate like bridges, but provide  
more ports for LAN connectivity and offer features that reduce collisions and latency  
on the network.  
CoS  
Class Of Service – Cos (IEEE 802.1p) defines eight different classes of service that are  
indicated in a 3-bit user_priority field in an IEEE 802.1Q header added to an Ethernet  
frame when using tagged frames on an 802.1 network.  
DSCP  
Differentiated Services Code Point – Also known as DiffServ, DSCP is a networking  
architecture that defines a simple, coarse-grained, class-based mechanism for classifying  
and managing network traffic and providing Quality of Service (QoS) guarantees on IP  
networks. RFC 2475, published in 1998 by the IETF, defines DSCP. DSCP operates by  
marking an 8-bit field in the IP packet header.  
IETF  
L2  
Internet Engineering Task Force – The IETF is an open standards organization that  
develops and promotes Internet standards.  
OSI Layer 2 (Ethernet) – Layer 2 of the seven layer OSI model is the Data Link Layer,  
on which the Ethernet protocol runs. Layer 2 is used to transfer data among network  
entities.  
LACP  
LLDP  
Link Aggregation Control Protocol – LACP is an IEEE specification that provides a way  
to combine multiple physical ports together to form a single logical channel. LACP  
allows load balancing by the connected devices.  
Link Layer Discovery Protocol (IEEE 802.1AB) – LLDP is a Layer 2 protocol used by  
network devices to communicate their identity, capabilities, and interconnections. This  
information is stored in a MIB database on each host, which can be queried with SNMP  
to determine the network topology. The information includes system name, port name,  
VLAN name, IP address, system capabilities (switching, routing), MAC address, link  
aggregation, and more.  
LLTD  
Link Layer Topology Discovery (Microsoft Standard) – LLTD is a Microsoft proprietary  
protocol with functionality similar to LLDP. It operates on wired or wireless networks  
(Ethernet 802.3 or wireless 802.11). LLTD is included on Windows Vista and Windows  
7, and can be installed on Windows XP.  
PDU  
Protocol Data Unit – In the context of the Switching feature, the Layer 2 PDU is the  
frame. It contains the link layer header followed by the packet.  
RSTP  
Rapid Spanning Tree Protocol (IEEE 802.1D-2004) – RSTP was defined in 1998 as an  
improvement to Spanning Tree Protocol. It provides faster spanning tree convergence  
after a topology change.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Glossary  
Solution Document Version History  
Version Number  
Date  
Notes  
1
2
3/30/2010  
5/19/2010  
This document was created by Susan Weigand  
Added conceptual information, more details about  
configuration, Troubleshooting and Technical FAQ  
sections. Embedded Port Mirroring screencast tutorial.  
3
6/29/2010  
Replaced embedded Port Mirroring screencast tutorial  
with final version. Added direct link to it as well.  
SonicOS 5.7: Advanced Switching Feature Guide and Screencast Tutorial  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Shark Carpet Cleaner S3505W User Manual
Sony DVD VCR Combo J H1 User Manual
Sony Speaker SRS A205 User Manual
Sony Video Game Console SCPH 35004 GT User Manual
Stovax Indoor Fireplace 8050 User Manual
Sub Zero Freezer IT 30FI User Manual
Sunbeam Food Saver VAC660 User Manual
Sylvania CRT Television 6427TD User Manual
Tanaka Saw 746280 User Manual
Targus Computer Drive 400 0084 001A User Manual