Solid State Logic Speaker 82S6XL090A User Manual

E Signature™ Channel  
Owner’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Solid State Logic  
XLogic  
SIGNATURE  
C H A N N E L  
Super-Analogue™ Outboard  
Owner’s Manual  
82S6XL090A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
Solid State Logic  
Begbroke, Oxford, England, OX5 1RU • +44 (0)1865 842300  
320 West 46th Street, 2nd Floor, New York, NY 10036, USA • +1 (1) 212 315 1111  
Suite 401, 5757 Wilshire Blvd, Los Angeles, CA 90036, USA • +1 (1) 323 549 9090  
3-55-14 Sendagaya, Shibuya-Ku, Tokyo 151-0051, Japan • +81 (0)3 5474 1144  
7 bis, rue de la Victoire, le Blanc Mesnil, Paris 93150, France • +33 (0)1 48 67 84 85  
Via Timavo 34, 20124 Milano, Italy • +39 (0)39 2328 094  
© Solid State Logic  
All Rights reserved under International and Pan-American Copyright Conventions  
E Series, E Signature, SL 4000 E Series, SL 9000 Series, Solid State Logic, SSL, XL 9000 Series  
and XLogic are trademarks of Solid State Logic  
All other product names and trademarks are the property of their respective owners  
No part of this publication may be reproduced in any form or  
by any means, whether mechanical or electronic, without the  
written permission of Solid State Logic, Oxford, England  
Initial Release (Rev. 0A), November 2005  
As research and development is a continual process, Solid State Logic reserves the right  
to change the features and specifications described herein without notice or obligation  
E&OE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
1.0 Introduction  
3
2.0 Safety Considerations  
Safety Warnings  
4
4
3.0 Installation  
6
6
7
7
Setting the mains voltage selector  
Mounting  
Connections  
4.0 Operation  
9
9
Input Section  
Listen Mic Compressor  
Dynamics Section  
Compressor/Limiter  
Expander/Gate  
Filter Section  
9
10  
10  
11  
11  
12  
12  
Equaliser Section  
Output Section  
5.0 Signal Routing  
Appendices:  
13  
A
B
C
D
E
Internal Links and Fuses  
Connector Details  
Electronic Specification  
Calibration Information  
Physical Specification  
Environmental Specification  
15  
16  
17  
21  
24  
24  
F
Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
oigc  
XL  
Blanking plate for  
(optional) ADC card  
Page 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
1.0 Introduction  
The XLogic E Signature Channel unit brings the classic sound of the original early 1980s E Series console to the  
outboard rack of today’s artists and producers. The XLogic E Signature Channel delivers the choice of selectable  
transformer driven or Variable Harmonic Drive (VHD) mic amps and the world renowned ‘Listen Mic’  
compressor – the secret weapon of many producers of the era – along with two distinctive Equaliser options  
coupled with the most musical dynamics processor available in either analogue or digital domain.  
An optional ADC card is available (SSL part number: 629945XT) to provide an additional digital audio output.  
The object of this manual is to provide purchasers of the XLogic E Signature Channel unit with information in  
the following areas:  
• Safety considerations  
• Installation requirement  
• Electrical connections and cabling  
• Connector pin outs  
• Specifications and physical dimensions  
Warranty  
The warranty period for this unit is 12 months from date of purchase.  
In Warranty Repairs  
In the event of a fault during the warranty period the unit must be returned to your local distributor who will  
arrange for it to be shipped to Solid State Logic for repair. All units should be shipped to Solid State Logic in their  
original packaging. Solid State Logic can not be held responsible for any damage caused by shipping units in  
other packaging. In such cases Solid State Logic will return the unit in a suitable box, which you will be charged  
for. Please do not send manuals, power leads or any other cables - Solid State Logic can not guarantee to return  
them to you. Please also note that warranty returns will only be accepted as such if accompanied by a copy of the  
receipt or other proof of purchase.  
Out of Warranty Repairs  
In the event of a fault after the warranty period has expired, return the unit in its original packaging to your local  
distributor for shipment to Solid State Logic. You will be charged for the time spent on the repair (at Solid State  
Logic's current repair rate) plus the cost of parts and shipping.  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
2.0 Safety considerations  
This section contains definitions and warnings, and practical information to ensure a safe working environment.  
Please take time to read this section before undertaking any installation work.  
2.1 Definitions  
‘Maintenance’  
All maintenance must be carried out by fully trained personnel. Note: it is advisable to observe suitable ESD  
precautions when maintenance to any part is undertaken.  
‘Non-User Adjustments’  
Adjustments or alterations to the equipment may affect the performance such that safety and/or international  
compliance standards may no longer be met. Any such adjustments must therefore only be carried out by fully  
trained personnel.  
‘Users’  
This equipment is designed for use solely by engineers and competent operators skilled in the use of professional  
audio equipment.  
‘Environment’  
This product is a Class A product intended to form an integrated component part of a professional audio  
recording, mixing, dubbing, film, TV, radio broadcast or similar studio wherein it will perform to specification  
providing that it is installed according to professional practice.  
2.2 Electrical Safety Warning  
When installing or servicing any item of Solid State Logic equipment with power applied, when cover  
panels are removed, HAZARDOUS CONDITIONS CAN EXIST.  
These hazards include:  
High voltages  
High energy stored in capacitors  
High currents available from DC power busses  
Hot component surfaces  
Any metal jewellery (watches, bracelets, neck-chains and rings) that could inadvertently come into contact  
with uninsulated parts should always be removed before reaching inside powered equipment.  
2.3 Installation  
Voltage Selection and Fusing  
All XLogic units have selectable voltage inlets. Always confirm that the input mains voltage range is set correctly  
before applying power. Always isolate the mains supply before changing the input range setting.  
If it is ever necessary to replace a blown mains-fuse, then always use the correct rating and type of replacement.  
If a correctly rated fuse continues to blow, then a fault exists and the cause should be investigated or the unit  
returned to Solid State Logic for repair/replacement as appropriate.  
Details of mains settings and correct fuse ratings can be found in Section 3.1 and Appendix A of this manual.  
Safety Earth Connection  
Any mains powered item of Solid State Logic equipment that is supplied with a 3-core mains lead (whether  
connectorised or not) should always have the earth wire connected to the mains supply ground. This is the safety  
earth and grounds the exposed metal parts of the racks and cases and should not be removed for any reason.  
Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Considerations  
Mains Supply and Phases  
Solid State Logic equipment is designed for connection to a single phase supply with the Neutral conductor at  
earth potential – category TN – and is fitted with a protective fuse in the Live conductor only. It is not designed  
for use with Phase (Live) and Neutral connections reversed or where the Neutral conductor is not at earth  
potential (TT or IT supplies).  
Mains cables will be coded with the following colour scheme:  
LIVE:  
Brown  
NEUTRAL:  
EARTH:  
Blue  
Yellow/Green  
Mains Isolation and Over-Current Protection  
An external disconnect device is required for this equipment; a detachable power cord, as fitted to this  
equipment, is a suitable disconnect device. Note that the socket outlet used for the detachable power cord should  
be installed near the equipment and should be easily accessible.  
An external over-current protection device is required to protect the wiring to this equipment which must be  
installed according to current wiring regulations. The fusing or breaking-current is defined in the environmental  
specification in the appendix of this manual. In certain countries this function is supplied by use of a fused plug.  
CE Certification  
Note that the majority of cables supplied with Solid State Logic equipment are fitted with ferrite rings  
at each end. This is to comply with current European CE regulations and these ferrites should not be  
removed.  
If any of the unit metalwork is modified in any way the CE certification status of the product may be  
adversely affected.  
FCC Certification  
The XLogic unit has been tested and found to comply with the limits for a Class A digital device, pursuant to part  
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference  
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate  
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause  
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause  
harmful interference in which case the user will be required to correct the interference at his own expense.  
Instructions for Disposal of WEEE by Users in the European Union  
The symbol shown here is on the product or on its packaging, which indicates that this product  
must not be disposed of with other waste. Instead, it is the user’s responsibility to dispose of  
their waste equipment by handing it over to a designated collection point for recycling of waste  
electrical and electronic equipment. The separate collection and recycling of your waste  
equipment at the time of disposal will help to conserve natural resources and ensure that it is  
recycled in a manner that protects human health and the environment. For more information  
about where you can drop off your waste equipment for recycling, please contact your local city  
office, your household waste disposal service or where you purchased the product.  
2.4 Graphical Symbols  
The following symbols may be used either on the product or in this manual:  
General hazard – refer to user or service  
Electrical hazard.  
manual for details.  
Protective Earth (ground).  
Frame or Chassis terminal.  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
3.0 Installation  
3.1 Voltage Selection  
Before connecting the mains supply ensure that the voltage range selector next to the IEC socket on the rear of  
the unit is correctly set. The input setting must be confirmed before applying power. The input module can be  
configured to be one of 4 voltage settings (one of which is invalid and should not be used – see below). The setting is  
indicated by a plastic pin protruding through the appropriate hole in the fuse panel.  
Lever here…  
Before Connecting to  
110V  
the supply, see the  
Installation Instructions.  
120V  
230V  
Voltage setting PCB  
240V  
DISCONNECT POWER  
BEFORE REPLACING FUSES  
(under cover)  
Mains Inlet Module (set for ‘240V’)  
The setting is altered by a small vertical PCB which can be fitted in 4 positions.  
To change the setting:  
Switch off and remove the IEC lead.  
Using a small flat-bladed screwdriver, lever open the fuse panel to the right of the connector.  
At the right hand side is a vertical PCB with a plastic key which indicates the setting. Using pliers, pull  
out the PCB.  
The PCB has to be rotated until the desired voltage is shown along the edge which plugs into the module.  
The plastic key (and this bit is quite fiddly) must also be rotated so that it points out of the module and so  
that the round pin aligns with the appropriate hole in the cover panel; (refer to the diagrams opposite).  
Re-insert the PCB and replace the fuse panel. The plastic pin should project through the appropriate hole.  
2 4 0  
2 3 0  
1 2 0  
1 0 0  
100  
120  
230  
240  
100V Setting  
(Use for 90-105V)  
120V Setting  
(Use for 105-125V)  
230V Setting  
(Do not use)  
240V Setting  
(Use for 220-240V)  
Mains Inlet Voltage Setting PCB  
These diagrams show the PCB arrangements for the different voltage settings.  
Note that where the mains voltage is a nominal 230V, the ‘240V Setting’ should be used – not the ‘230V Setting’!  
Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation and Operation  
3.2 Mounting  
This unit is designed to be rack-mounted. It is 1 RU (44.5mm/1.75 inch) high, its depth is:  
325 mm/12.8 inches not including heatsink.  
365 mm/14.3 inches including heatsink  
400 mm/15.75 inches including connectors  
The XLogic E Signature Channel units incorporate reinforcement brackets into the chassis and so are suitable for  
direct rack-mounting. A 1RU space should be left above each unit to ensure adequate ventilation.  
3.3 Connection  
There are five connectors on the rear panel:  
OUTPUT  
KEY IN  
INPUT  
LINE  
IN  
• OUTPUT (male XLR)  
• KEY IN  
• LINE IN  
• LINK  
(female XLR)  
(TRS jack socket)  
(TRS jack socket)  
(female XLR)  
LINK  
• INPUT  
The XLR labelled ‘INPUT’ is for microphone signals; the ‘LINE IN’ jack socket is for line level signals such as a  
synthesiser or DAW output. Neither input is suitable for use with guitar pickups, piezo electric bugs etc.  
If you have more than one unit, the dynamics side-chain of multiple units may be linked together by connecting  
the ‘LINK’ jacks together using a mono or stereo jack-to-jack cable(s).  
The ‘KEY IN’ XLR provides line level access to the dynamics side-chain to enable the dynamics to be keyed from  
external sources.  
The XLR labelled ‘OUTPUT’ is a line level output; connect this to your recorder, workstation or mixing desk.  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
XLogic E Signature™ Channel Block Diagram  
Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation and Operation  
4.0 Operation  
The XLogic E Signature Channel unit is a 1U rack mounting unit containing a complete set of signal processing  
based upon the SL 4000 E Series channel strip – Input, Compressor/Limiter, Expander/Gate, Hi and Lo pass  
Filters and Equaliser.  
The signal processing order can be changed and the EQ and Filter sections used in the Dynamics side chain.  
providing a wide range of signal processing options.  
Obviously there are many different permutations of signal routing, allowing an enormous number of creative  
possibilities. This section looks at each control on the XLogic E Signature Channel individually, working from left  
to right, with a brief summary of the routing possibilities. See Section 5 for more on routing.  
4.1 Input Section  
The Input section contains two completely independent Mic amps  
together with an electronically balanced Line input with its own  
gain control. The primary Mic amp is a classic transformer  
DRIVE  
INPUT  
Ø
ON  
LINE  
coupled design using the same Jensen component as the original  
E Series channel strips. The second option is engaged via the ON  
switch. This replaces the original preamp with a new electronically  
balanced design with SSL's unique variable harmonic drive  
circuitry. This unique preamp emulates the overload  
characteristics of a traditional valve/tube design but with the  
ability to tailor the warmth or musicality via the DRIVE control.  
This shapes the overload curve to provide a user controlled blend  
of 2nd or 3rd harmonic distortion.  
3RD  
2ND  
0
MIC  
+70  
LINE  
PAD  
48V  
+20  
-20  
+20  
Both of these preamps use the same gain control providing +20dB to +70dB gain and share a passive front  
end with a switchable 22dB Input Pad and +48V phantom powering.  
Please note that connecting a microphone to the XLogic E Signature Channel unit with phantom power switched on  
is not advised as it may cause damage to either the microphone or the input stage of the XLogic unit. Take care not  
to connect line level sources (keyboards etc.) to the microphone input with phantom power switched on as this may  
damage the output stage of the connected unit.  
A Ø (Phase) switch is provide to reverse the phase of the selected channel input.  
4.2 Listen Mic Compressor  
The SSL ‘Listen Mic’ Compressor was, throughout the 1980’s, the secret weapon in  
many producers sonic arsenal of recording techniques. Originally designed to prevent  
LCOMP  
overloading the return feed from a studio communications mic, its fixed attack and  
release curves were eminently suitable for use on ambient drums mics. The console  
LESS  
MORE  
surgery required to gain access to the compressed output was performed on many  
early E Series consoles before it became a standard modification on latter production  
systems. The original circuit has been added into the XLogic E Signature Channel unit,  
enhanced with the addition of a front panel threshold adjustment and a simple traffic  
light indication of gain reduction. Due to the vagaries of the original design, the range  
of the threshold control is indicated as either LESS or MORE! The gain reduction  
indication takes the form of a bi-colour LED located under the IN switch; it will glow  
green to show that it is in-circuit and then progressively redder as more compression  
IN  
is applied. The circuit follows directly after the input stage allowing either microphone or line level signals  
to benefit from the sonic possibilities provided by this compressor.  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
4.3 Dynamics Section  
The Dynamics section of the XLogic E Signature Channel unit comprises a compressor/limiter and an  
expander/gate, both of which use the same gain change element. The design returns faithfully to the  
circuit and key components which defined the sound of the original E Series channel strip. A true RMS  
converter is used in the side chain whilst the gain element is an all discrete design identical to the Class A  
VCA chip used in the original unit. The compressor contains additional switching options to defeat the  
over-easy curve and to use a linear release instead of the more usual logarithmic curve. The result is a  
compressor with three distinct voicings, all of which contributed to the many classic records tracked and  
mixed on early E Series consoles.  
As in the original E Series channel strip, the Filter and/or the Equaliser section can be assigned to the  
dynamics side chain allowing de-essing etc.  
The Dynamics section has some master function buttons associated with it. Section 5  
deals with Dynamics routing in more detail, but briefly these buttons function as  
DYNAMICS  
follows:  
DYN  
IN  
PRE  
EQ  
DYN IN – Switches the Dynamics section into the signal path, post the EQ.  
PRE EQ – Places the Dynamics section pre the EQ section (but post the Filter section if  
the Filter INPUT switch is pressed).  
KEY  
LINK  
KEY – Switches the Dynamics side chain to the ‘KEY’ input on the rear panel of the unit.  
If you have more than one unit and have connected the ‘LINK’ jacks on the rear of the  
units together, the side chain control signals of multiple units can be linked by pressing  
the LINK switch on those units you wish to gang. When two Dynamics sections are  
linked, the control voltages of each section sum together, so that whichever section has  
the most gain reduction will control the other section.  
Don’t try to link two gates using the LINK switch when you want the signal on one to open the other. If you need to  
achieve this effect, take a keying signal from one section to trigger the other. The easiest way to do this is by patching  
from the output of the ‘source’ channel into the ‘KEY’ input of the ‘destination’ channel, and selecting KEY (see  
above) on this channel.  
4.4 Compressor/Limiter  
RATIO – When turned to 1:1, the  
Compressor/Limiter section is  
inactive. Turning the control  
T/HOLD  
-20  
T/HOLD  
0
COMPRESSOR  
GATE  
0
3
6
10 14 20  
FAST  
ATK  
FAST  
ATK  
EXP  
clockwise  
increases  
the  
+10  
-30  
+10  
compression ratio to give a true  
limiter at the fully clockwise  
position.  
RELEASE  
RATIO  
RELEASE  
RANGE  
LIN  
REL  
The compressor ordinarily has  
an ‘over-easy’ characteristic.  
.1  
4
1
.1  
4
0
40  
Selecting  
peak sensing, and replaces the  
’over-easy’ characteristic with a ‘hard knee’, providing an alternative for some instruments.  
changes this to  
THRESHOLD – Whenever a signal exceeds the level set by this control, the compressor will start to act at  
the ratio set by the RATIO control. This control also provides automatic make-up gain, so as you lower the  
threshold and introduce more compression, the output level is increased, maintaining a steady output  
level regardless of the amount of compression.  
RELEASE – Sets the time constant (speed) with which the compressor returns to normal gain settings once  
the signal has passed its maximum.  
FAST ATT – Provides a faster attack time (3mS for 20dB gain reduction). When off the attack time is slower  
and less aggressive (30mS for 20dB gain reduction).  
LIN REL – Changes the release curve from logarithmic to linear. This also raises the threshold by 6dB.  
The yellow and red LEDs, on the bottom of the LED display area, indicate the amount of gain reduction  
(compression).  
Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation and Operation  
4.5 Expander/Gate  
The Expander/Gate section can  
T/HOLD  
-20  
T/HOLD  
COMPRESSOR  
GATE  
act either as a :1 Gate or, when  
0
0
the EXP switch is pressed, as a  
3
6
10 14 20  
FAST  
ATK  
FAST  
EXP  
ATK  
2:1 Expander.  
+10  
-30  
+10  
RELEASE  
RATIO  
RELEASE  
RANGE  
RANGE – Determines the depth  
of gating or expansion. When  
turned fully anti-clockwise, the  
Expander/Gate section will be  
inactive. When turned fully  
clockwise, a range of 40dB can be  
obtained.  
LIN  
REL  
.1  
4
1
.1  
4
0
40  
THRESHOLD Variable hysteresis is incorporated in the threshold circuitry. For any given ‘open’ setting,  
the Expander/Gate will have a lower ‘close’ threshold. The hysteresis value is increased as the threshold  
is lowered. This is very useful in music recording as it allows instruments to decay below the open  
threshold before gating or expansion takes place.  
RELEASE – This determines the time constant (speed), variable from 0.1 – 4 seconds, at which the  
Gate/Expander reduces the signal level once it has passed below the threshold. Note that this control  
interacts with the Range control.  
FAST ATT – Provides a fast attack time (100µs per 40db). When off, a controlled linear attack time of 1.5ms  
per 40dB is selected. The attack time is the time taken for the Expander/Gate to ‘recover’ once the signal  
level is above the threshold. When gating signals with a steep rising edge, such as drums, a slow attack  
may effectively mask the initial ‘THWACK’, so you should be aware of this when selecting the appropriate  
attack time.  
The green LEDs in the display section indicate Expander/Gate activity (the amount of gain reduction).  
4.6 Filters Section  
In common with the original E Series Channel strip, a pair of high- and  
low-pass Filters are provided. Both Filter controls incorporate bypass  
switching which is activated when turned fully anti-clockwise; turning  
either control up will put that band in circuit, illuminating the LED  
adjacent to the control to indicate this state. The Filters are normally  
placed post- the EQ but can be routed to different audio paths within the  
module. Both Filters normally exhibit a 12dB/octave but pressing the  
BLK switch in the EQ section will modify the slope of the high-pass  
Filter to 18dB/octave – see Section 4.7 overleaf for more detail on this  
switch. Section 5 describes the routing combinations in more detail but,  
briefly, these buttons function as described below.  
KHz  
FILTERS  
8
4
12  
3.5  
DYN  
S/C  
INPUT  
OUT  
3
Hz  
200  
70  
20  
300  
350  
OUT  
DYN SC – The Filters are switched into the sidechain of the Dynamics section. The Equaliser can be  
switched into the sidechain independently. Note that DYN SC overrides the INPUT function (see below).  
INPUT – Moves the Filters to put them in circuit immediately post the Channel Input section. This allows  
the Filters to be used to clean up signals before compressing them. Selecting Dynamics ‘PRE EQ’ will allow  
the compressed signal to be EQ’d.  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
4.7 Equaliser Section  
The XLogic E Signature Channel unit equaliser section defaults to the original ‘Brown Knob’ circuit that  
was standard on all early production E Series consoles. The two parametric mid-band sections feature  
SSL’s classic logarithmically symmetric design that ensures that the 3dB up/down points retain the same  
musical interval from the centre frequency regardless of frequency and amplitude settings. The two  
shelving sections are traditional 6dB/octave designs with an option for a fixed Q parametric response  
(Bell). The ‘02’ EQ, to give it its correct name, was used on countless recordings and mixes in the early  
eighties. It is offered here incorporating a switchable version of a field modification that was carried out  
on a number of consoles – the CT OUT switch defeats the inherent non-interactive nature of the design  
and introduces subtle control interactions similar to those found on earlier parametric units. It also offers  
a different gain law with increased resolution in the critical initial boost or cut area. This function can be  
selected individually for each band.  
In 1983 a new ‘242’ EQ circuit was developed in conjunction with the legendary George Martin for the first  
SSL console to be installed in AIR studios. The ‘Black Knob’ EQ, as it became known, featured enhanced  
cut and boost ranges ( 18dB instead of 15dB) together with a different control law and a steeper  
18dB/octave high pass filter for tighter control of low frequencies. It is this design which is retained today  
as the ‘E Series’ EQ option of the SL and XL 9000 Series consoles and the XLogic Channel unit. The design  
is enhanced in this version via the CT OUT option for additional tonal variations and is activated by  
pressing the BLK switch.  
GAIN  
GAIN  
GAIN  
GAIN  
LF  
LMF  
HMF  
HF  
EQ  
IN  
DYN  
S/C  
BELL  
BLK  
BELL  
+
+
+
+
Hz  
300  
Q
KHz  
Q
KHz  
KHz  
5
10  
16  
100  
50  
.8  
1.5  
1.5  
.8  
4.5  
.3  
2.0  
2
14  
CT  
OUT  
CT  
OUT  
CT  
OUT  
CT  
OUT  
30  
450  
.2  
2.5  
.6  
7
1.5  
As mentioned above, the EQ section has some master function buttons associated with it:  
EQ IN – Switches the EQ section into circuit.  
BLK – Switches the EQ from ‘Brown Knob’ operation to ‘Black Knob’ operation – see above.  
DYN SC – Switches the EQ section into the sidechain of the Dynamics section. The Filter section can be  
switched independently of the EQ section. If both Filter and EQ sections are assigned to the dynamic  
sidechain the Filter section precedes the EQ. Section 5 describes the routing combinations in more detail.  
4.8 Output Section  
The Output section consists of a centre indented, 20dB output gain  
control and a 7-segment LED meter. Normally the meter reads the output  
of the channel, but selecting MTR INPUT will meter the signal  
immediately post the input section.  
GAIN  
OUTPUT  
MTR  
INPUT  
-20  
+20  
POWER  
The blue POWER LED indicates that the unit is powered (what else?).  
ADC LOCK  
The ADC LOCK LED is a bi-colour LED which indicates that the  
(optional) ADC card is locked to an external clock. It will illuminate  
yellow to indicate external lock, red for internal lock.  
-24 -12  
0
6
12 18 24  
Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation and Operation  
5.0 Signal Routing  
Channel Processing Order  
There are two switches that control the order of the signal processing elements. These are Filters to INPUT and  
Dynamics PRE EQ. The table below shows the effect of these:  
Filters  
Dynamics  
PRE  
EQ  
IP  
4 Band EQ  
Filters  
Filters  
Dynamics  
Dynamics  
Filters  
PRE  
EQ  
IP  
IP  
IP  
4 Band EQ  
4 Band EQ  
Dynamics  
PRE  
EQ  
Dynamics  
Filters  
PRE  
EQ  
4 Band EQ  
Side Chain Processing Order  
The EQ and Filter sections can be assigned to the dynamics side chain using the DYN S/CH switches in the  
respective sections. The table below shows the sidechain source and processing for the various combinations of  
these:  
EQ  
Filters  
Dynamics  
DYN  
S/C  
DYN  
PRE  
EQ  
IP  
IP  
IP  
IP  
IP  
IP  
4 Band EQ  
4 Band EQ  
Filters  
Dynamics  
Dynamics  
4 Band EQ  
Dynamics  
S/C  
Key  
DYN  
S/C  
DYN  
S/C  
PRE  
EQ  
Key  
Filters  
DYN  
S/C  
DYN  
S/C  
PRE  
EQ  
Dynamics  
Key  
Filters  
PRE  
EQ  
DYN  
S/C  
DYN  
S/C  
Filters  
Key  
4 Band EQ  
DYN  
S/C  
DYN  
S/C  
PRE  
EQ  
Dynamics  
4 Band EQ  
Filters  
Key  
Key  
DYN  
S/C  
DYN  
S/C  
PRE  
EQ  
Dynamics  
4 Band EQ  
Filters  
Note that the side chain can be fed from the KEY input on the rear of the unit by selecting KEY.  
Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
Stop looking – we left this page blank…  
Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Appendix A – Internal Links and Fuses  
Fuses (Mains Inlet)  
The mains inlet contains a single 1 amp 1.25" time delay fuse (SSL Part No. 35FJJ310). To change it disconnect the  
mains inlet, then using a small screwdriver prise open the mains selector cover (see illustration on page 6.).  
Under this cover is a removable carrier that contains the fuse – pull the carrier out to access the fuse inside. Test  
and replace the fuse with the same type and value if necessary.  
Internal Fuses  
The internal power rails are also individually fused. These fuses should only be changed by suitably experienced  
staff. They are listed below:  
Fuses (629610X2 Power Regulator Card)  
+48V FS1 - 500mA wire ended (SSL part No. 35F5E250)  
Fuses (629612X1 Main Card)  
–18V FS1 - 3 amp wire ended (SSL part No. 35F5E330)  
–15V FS2 - 3 amp wire ended (SSL part No. 35F5E330)  
+15V FS3 - 3 amp wire ended (SSL part No. 35F5E330)  
+18V FS4 - 3 amp wire ended (SSL part No. 35F5E330)  
+5V FS5 - 3 amp wire ended (SSL part No. 35F5E330)  
Links  
LK1 Compressor ‘Auto Attack’. Normally not fitted.  
Fitting across pins 1 & 2 makes the compressor attack time program dependent when ‘Linear  
Release’ is selected.  
Fitting across pins 2 & 3 makes the compressor attack time program dependent normal  
(logarithmic) release is selected.  
LK2 Additional HF roll-off for Mic input transformer. Normally disabled by fitting across pins 1 & 2, fit  
across pins 2 & 3 to enable.  
LK3 Solder link. Links digital and analogue 0V. Do not remove.  
LK4 Links chassis and analogue 0V. Normally fitted. Remove to increase impedance to 10Ω.  
Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
Appendix B – Connector Details  
Input  
Output  
Location:  
Rear Panel  
Location:  
Rear Panel  
Conn' Type: XLR Female  
Conn' Type: XLR Male  
Pin  
Description  
Chassis  
Audio +ve  
Audio -ve  
Pin  
Description  
1
2
3
1
2
3
Chassis  
Audio +ve  
Audio -ve  
Line In  
Key In  
Location:  
Rear Panel  
Location:  
Rear Panel  
Conn' Type: TRS Jack Socket  
Conn' Type: XLR Female  
Pin  
Description  
Pin  
Description  
Tip  
Ring  
Sleeve  
Audio +ve  
Audio -ve  
Chassis  
1
2
3
Chassis  
Audio +ve  
Audio -ve  
Link  
Location:  
Rear Panel  
Conn' Type: TRS Jack Socket  
Pin  
Description  
Tip  
Ring  
Sleeve  
Link Bus *  
Link Bus *  
Chassis  
* Tip and Ring are linked to allow use of mono jacks  
Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Appendix C – Performance Specification  
The following pages contain audio performance specification figures for the XLogic E Signature Channel unit.  
No other Solid State Logic products are covered by this document and the performance of other Solid State Logic  
products can not be inferred from the data contained herein.  
Measurement Conditions  
For each set of figures on the following pages, the specific unit and test setup will be stated at the beginning of  
that section. Any changes to the specified setup for any particular figure(s) will be detailed beside the figures to  
which that difference applies.  
Measurement References  
Unless otherwise specified the references used in this specification are as follows:  
• Reference frequency:  
1kHz  
• Reference level:  
0dBu, where 0dBu ≈ 0.775V into any load  
• Source impedance of Test Set:  
• Input impedance of Test Set:  
50Ω  
100kΩ  
• All unweighted measurements are specified as 22Hz to 22kHz band limited RMS and are expressed in  
units of dBu  
• All distortion measurements are specified with a 36dB/Octave low pass filter at 80kHz and are expressed  
as a percentage  
• The onset of clipping (for headroom measurements) should be taken as 1% THD  
• Unless otherwise quoted all figures have a tolerance of 0.5dB or 5%  
Microphone Input 1 (Transformer Coupled)  
Measurement Conditions  
Signal applied to Mic Input and measured at Output. Pad switched out and Mic Gain control set to +20dB.  
Gain  
Continuously variable from +20dB to +70dB  
Independently switchable 22dB Pad available  
Input Impedance  
Output Headroom  
> 1.2kΩ  
> +26dBu at onset of clipping  
< 0.025% from 20Hz – 20kHz  
THD + Noise  
(-12dBu applied, +36dB gain)  
Frequency Response  
0.25dB from 20Hz to 20kHz  
Equivalent Input Noise  
< –128dBu at maximum gain (input terminated with 150Ω)  
Common Mode Rejection  
(-10dBu applied, +30dB gain)  
> 90dB from 50Hz to 1kHz  
> 80dB at 10kHz  
Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
Microphone Input 2 (Electronically Balanced)  
Measurement Conditions  
Signal applied to Mic Input and measured at Output. Pad switched out and Mic Gain control set to +20dB.  
Gain  
Continuously variable from +20dB to +70dB  
Independently switchable 22dB Pad available  
Input Impedance  
Output Headroom  
> 1.2kΩ  
> +26dBu at onset of clipping  
Adjustable between < 0.05% and 5% from 20Hz – 20kHz  
THD + Noise  
(-12dBu applied, +36dB gain)  
Frequency Response  
0.3dB from 20Hz to 20kHz  
Equivalent Input Noise  
< –127dBu at maximum gain (input terminated with 150Ω)  
Common Mode Rejection  
(-10dBu applied, +30dB gain)  
> 75dB from 50Hz to 1kHz  
> 65dB at 10kHz  
Line Input  
Measurement Conditions  
Signal applied to Line Input and measured at Output. Input Gain set to indent (0dB).  
Gain  
Continuously variable from –20dB to +20dB  
6kΩ  
Input Impedance  
THD + Noise  
< 0.005% from 20Hz to 20kHz  
(+24dBu applied, 0dB gain)  
Frequency Response  
0.25dB from 20Hz to 20kHz  
< –89dBu  
Equivalent Input Noise  
(Input terminated with 150Ω)  
Channel Output  
Output is fully balanced and floating.  
Gain  
Continuously variable from –20dB to +20dB with indent at 0dB position  
Output Headroom  
Output Impedance  
> +26dBu at onset of clipping  
< 80Ω  
Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Equaliser  
This is a four band equaliser that can be switched between two different sets of curves; one based on SSL’s ‘02’  
(‘Brown Knob’) EQ and the other based on the latest version of the classic ‘242’ E Series (‘Black Knob’) EQ. High  
and low pass filters are also available.  
HF Band controls:  
Frequency  
Gain  
Variable from 1.5kHz to 16kHz  
Variable between 15dB (‘02’)  
Variable between 18dB (‘242’)  
‘Q’ (on ‘BELL’ setting)  
0.8 (‘02’)  
1.3 (‘242’)  
HMF Band controls:  
Frequency  
Variable from 600Hz to 7kHz  
Gain  
Variable between 15dB (‘02’)  
Variable between 18dB (‘242’)  
‘Q’  
Variable from 0.5 to 2.5 (‘02’)  
Variable from 0.5 to 4 (‘242’)  
LMF Band controls:  
Frequency  
Variable from 200Hz to 2.5kHz  
Gain  
Variable between 15dB (‘02’)  
Variable between 18dB (‘242’)  
‘Q’  
Variable from 0.5 to 2.5 (‘02’)  
Variable from 0.5 to 4 (‘242’)  
LF Band controls:  
Frequency  
Variable from 30Hz to 450Hz  
Gain  
Variable between 15dB (‘02’)  
Variable between 18dB (‘242’)  
‘Q’ (on ‘BELL’ setting)  
0.8 (‘02’)  
1.3 (‘242’)  
Filter controls:  
Low Pass Frequency  
3kHz to 16kHz (–3dB Point)  
12dB/octave  
Low Pass Slope  
High Pass Frequency  
High Pass Slope  
20Hz to 350Hz (–3dB Point)  
12dB/octave (‘02’)  
18dB/octave (’242’)  
Measurement Conditions  
Signal applied to Line Input and measured at Output. EQ switched In. All EQ controls set centre as appropriate.  
THD + N  
< 0.05% at +20dBu 1kHz  
0.25dB from 20Hz to 20kHz  
> +26dBu at onset of clipping  
< –73dBu  
Frequency Response  
Output Headroom  
Noise  
Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
Dynamics  
The unit contains a complete dynamics section, the functions of which split into two areas;  
a Compressor/Limiter and an Expander/Gate.  
Compressor/Limiter  
Controls:  
Ratio (slope)  
Threshold  
Variable from 1 to infinity (limit)  
Variable from +10dB to –30dB  
Attack Slope  
Attack Time  
Release  
Normally ‘Over Easy’, switchable to ‘Hard Knee’  
Normally 30mS per 20dB*, switchable to 3mS (‘Fast Att’)  
Variable from 0.1 to 4 seconds  
Release Slope  
Normally ‘Logarithmic’, switchable to ‘Linear’  
The Compressor/Limiter has two different attack slope modes and two different release slope modes; ‘Hard  
Knee’ & ‘Over Easy’ and ‘Logarithmic’ & ‘Linear’ respectively. As their names suggest these modes affect of  
manner of response to incoming signals. Combining the two modes provides four very different modes of  
compression and limiting with the ‘Hard Knee’ and ‘Linear’ modes giving far more dramatic compression  
characteristics.  
* When LK1 not fitted (default).  
Expander/Gate  
Controls:  
Range  
Variable from 0 to 40dB  
Threshold  
Attack Time  
Release Time  
Variable from –30dB to +10dB  
Normally 1.5mS per 40dB, switchable to 100µs  
Variable from 0.1 to 4 seconds  
The side chain signal can be sourced either from the signal feeding the dynamics section or the external Key  
input. The Filters and/or the EQ can be inserted in the sidechain.  
LED meters independently indicate amount of compression and expansion.  
Measurement Conditions  
Signal applied to Line Input and measured at Output. All pots anti-clockwise and switches ‘out’ except for  
Dynamics ‘IN’.  
THD + N (+20dBu applied)  
Output Headroom  
Frequency Response  
Noise  
< 0.1% at 1kHz  
> +26dBu at onset of clipping  
0.25dB from 20Hz to 20kHz  
< –73dBu  
Page 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Appendix D - Calibration Information  
The XLogic E Signature Channel unit is factory calibrated and should only need calibration if a potentiometer or  
other component has been replaced or if it is suspected that there is a problem with calibration.  
In all of the following instructions it is assumed that the lid has been removed and that power has been applied.  
It is also assumed that unless otherwise specified, all switches are released and all potentiometers are at unity,  
minimum or indent position as appropriate. The required accuracy for each adjustment will be specified along  
with the target value.  
All level and distortion measurements should be made with audio-band 20Hz to 20kHz filters unless otherwise  
specified. All adjustments are made on the main (629612) card.  
Line Input  
Equipment Required:  
Calibrated audio oscillator and audio level meter  
1kHz sinewave @ +6dBu  
Test Signal:  
Input and Output:  
Unit Setup:  
Oscillator to Line Input and TP46 on the 629612 card to the audio level meter  
Set the Line Gain to indent (0dB)  
Level Trim  
Adjustment:  
1. Adjust VR2 for 0dBu 0.05dB.  
Output Stage  
Equipment Required:  
Calibrated audio oscillator, audio level meter and dc. volt meter. A ‘balance’  
adaptor (see below) will be required for the output balance adjustment.  
Test Signal:  
1kHz sinewave @ 0dBu  
Input and Output:  
Unit Setup:  
Oscillator to Line Input and Output to the audio level meter  
1. Set both Line Gain and Output Gain to indent (0dB).  
2. Press LINE switch IN.  
Unity Gain Trim  
Adjustment:  
1. Adjust VR28 for 0dBu 0.05dB.  
DC Offset Trim  
Adjustment:  
1. Turn Oscillator off.  
2. Measure on TP54 and adjust VR29 for 0V 1mV.  
3. Measure on TP59 and adjust VR30 for 0V 1mV.  
Output Balance  
Input and Output:  
Signal source as before, connect the Output to the audio level meter via the  
‘balance’ adaptor  
Adjustment:  
1. Adjust VR31 for minimum level (< 55dBr).  
‘Balance’ Adaptor  
For the output balance adjustment, a ‘balance’  
adaptor such as that illustrated here will be required.  
This adaptor consists of a pair of close tolerance  
resistors in an in-line cable and is used to sum  
together a balanced output in order to correctly  
adjust the level balance of the measured output;  
perfect balance should result in complete signal  
cancellation.  
1
2
3
3
2
1
0V  
+
5K01** 1  
5K01** 1  
From unit  
under test  
To measuring 2  
equipment  
+
0V  
1.  
2.  
Note  
Resistor tolerence should ideally be 0.01%  
Absolute level measured will depend upon the input  
impedence of the measuring equipment.  
Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
Meter Calibration  
Equipment Required:  
Calibrated audio oscillator and audio level meter  
Test Signal:  
1kHz sinewave @ +24dBu  
Input and Output:  
Unit Setup:  
Oscillator to Line Input and Output to the audio level meter  
1. Set both Line Gain and Output Gain to indent (0dB).  
2. Check for +24dBu output level.  
Adjustment:  
1. Adjust VR24 until the ‘+24’ meter LED is just illuminated.  
2. Reduce oscillator level to +18dBu, then +12dBu etc. and check that the correct  
meter LEDs light. At each point, reduce the level slightly using the Output Gain  
control and check each LED extinguishes.  
EQ Alignments  
Equipment Required:  
Test Signal:  
Calibrated audio oscillator and audio level meter  
Sinewave @ 0dBu, frequencies as specified below  
Oscillator to Line Input and Output to the audio level meter  
Input and Output:  
Unit Setup:  
1. Set both Line Gain and Output Gain to indent (0dB). Check that the Filters and  
Dynamics are switched out.  
2. Switch the EQ in and release all other EQ switches.  
3. Set all of the Q and Frequency controls fully anti-clockwise and all EQ gain  
controls to their centre indent.  
LF EQ – Maximum Gain  
Adjustment:  
1. Ensure that the BLK switch is released.  
2. Set LF Gain to maximum and select LF BELL. Set the audio oscillator for 80Hz  
and adjust LF Frequency to find the maximum level on the audio level meter.  
3. Adjust VR4 for +15dBu 0.25dB.  
4. Switch BLK in and re-adjust LF Frequency for maximum level.  
5. Adjust VR6 for +18dBu 0.25dB.  
6. Reset LF Gain to its centre indent position, release the BLK switch and de-select  
LF BELL. Re-check the audio level meter for 0dBu.  
LMF EQ – Maximum Gain  
Adjustment:  
1. Ensure that the BLK switch is released.  
2. Set LMF Gain to maximum and LMF Q fully anti-clockwise. Set the audio  
oscillator for 1kHz and adjust LMF Frequency to find the maximum level on the  
audio level meter.  
3. Adjust VR9 for +15dBu 0.25dB.  
4. Switch BLK in and re-adjust LMF Frequency for maximum level.  
5. Adjust VR12 for +18dBu 0.25dB.  
6. Reset LMF Gain to its centre indent position and release the BLK switch. Re-  
check the audio level meter for 0dBu.  
HMF EQ – Maximum Gain  
Adjustment:  
1. Ensure that the BLK switch is released.  
2. Set HMF Gain to maximum and HMF Q fully anti-clockwise. Set the audio  
oscillator for 3kHz and adjust HMF Frequency to find the maximum level on the  
audio level meter.  
3. Adjust VR14 for +15dBu 0.25dB.  
Page 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
4. Switch BLK in and re-adjust HMF Frequency for maximum level.  
5. Adjust VR16 for +18dBu 0.25dB.  
6. Reset HMF Gain to its centre indent position and release the BLK switch. Re-  
check the audio level meter for 0dBu.  
HF EQ – Maximum Gain  
Adjustment:  
1. Ensure that the BLK switch is released.  
2. Set HF Gain to maximum and select HF BELL. Set the audio oscillator for 12kHz  
and adjust HF Frequency to find the maximum level on the audio level meter.  
3. Adjust VR19 for +15dBu 0.25dB.  
4. Switch BLK in and re-adjust HF Frequency for maximum level.  
5. Adjust VR21 for +18dBu 0.25dB.  
6. Reset HF Gain to its centre indent position, de-select HF BELL and release the  
BLK switch. Re-check the audio level meter for 0dBu.  
Dynamics Adjustments  
If the dynamics circuitry requires adjustment the following procedure should be followed in the order shown, in  
its entirety. All presets are on the 629612 card.  
Equipment Required:  
Test Signal:  
Calibrated audio oscillator, audio level meter and a (digital) dc. volt meter  
1kHz sinewave unless specified otherwise, level as specified  
Oscillator to Line Input, Output to the audio level meter.  
Input and Output:  
Unit Setup:  
Switch the dynamics IN and the EQ and Filter sections OUT, set all of the  
dynamics controls anti-clockwise and release all switches  
Unity Gain  
Adjustment:  
1. Set the oscillator for 0dBu.  
2. Adjust VR26 for 0dBu 0.05dB.  
RMS-to-DC Converter Gain  
Adjustment:  
1. Set the oscillator for –3.2dBu.  
2. Measure on TP30 and adjust VR27 for –1.7V 50mV.  
RMS-to-DC Converter DC Offset  
Adjustment:  
1. Set the oscillator for 0dBu.  
2. Measure on TP22 and adjust VR25 for –3.0V 50mV.  
Gate Threshold  
Adjustment:  
1. Set the oscillator for +14dBu.  
2. Adjust VR25 until the gate just opens.  
3. Check this adjustment by changing the oscillator level a little. Re-adjust VR25 if  
necessary so that the gate just opens when a +14dBu signal @ 1kHz is applied.  
Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
Appendix E – Physical specification *  
Depth:  
363mm / 14.3 inches  
casing and heatsink, excluding front panel knob(s)  
and rear connectors  
425mm / 16.75 inches  
including connectors, excluding front panel knob(s)  
Height:  
Width:  
44.5mm / 1.75 inches (1 RU)  
444mm / 17.5 inches  
481mm / 19 inches  
casing only  
including rack ears  
Weight:  
4.0kg / 9 pounds  
35 Watts / 47 VA  
Power:  
Boxed size:  
520mm x 520mm x 182mm / 20.5" x 20.5" x 7.2"  
6.3kg / 14 pounds  
Boxed weight:  
* All values are approximate  
Appendix F – Environmental Specification  
Temperature  
Operating:  
5 to 30 Deg. C  
Non-operating:  
Max. gradient:  
–20 to 50 Deg. C  
15 Deg. C/Hour  
Relative Humidity  
Operating:  
20 to 80 %  
Non-operating:  
Max. wet bulb:  
5 to 90 %  
29 Deg. C (non-condensing)  
Vibration  
Shock  
Operating:  
Non-operating, power off:  
< 0.2 G (3 - 100Hz)  
< 0.4 G (3 - 100Hz)  
Operating:  
Non-operating:  
< 2 G (10mSec. Max.)  
< 10 G (10mSec. Max.)  
Altitude  
Operating:  
Non-operating:  
0 to 3000m (above sea level)  
0 to 12000m  
Page 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Notes  
Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XLogic E Signature™ Channel Owner’s Manual  
Page 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sennheiser SONAR RS 110 User Manual
Sony Headphones MDR AS20J User Manual
Sony Home Theater System 4 130 029 131 User Manual
Sony Printer CPPM NR40 User Manual
Star Manufacturing Electric Grill 30CBDE User Manual
State Industries Electric Heater 50 YRVIT User Manual
Stovax Stove 8700CFCHEC User Manual
Sun Microsystems Network Card Ethernet PCI Adapter User Manual
Swann Home Security System SW244 CVD User Manual
System Sensor Smoke Alarm FTX P1 User Manual