Soleus Air Air Conditioner PA1 12R 32 User Manual

Portable Air Conditioner, Heat Pump Heater,  
Dehumidifier, Fan, & HEPA Air Purifier  
PA1-12R-32 / PA1-14R-32  
Operating Instructions  
3046364  
Model No. PA1-12R-32 / PA1-14R-32  
© 2008 Soleus Air International  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PACKAGE CONTENTS  
Portable Air Conditioner  
Exhaust Hoses (1)  
Hose Adapters (1)  
Window Kit Adapter (1)  
HEPA Filter (1)  
Remote Control  
AAA Batteries (2)  
Window Kit - 3 Sliding Panels (1 single hose panel, 2 extension panels)  
Owner’s Manual  
SPECIFICATIONS  
The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F.  
Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.  
Power consumption is measured when the fan runs at the highest speed setting.  
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.  
If the environment temperature is higher than the max operating temperature or lower than the minimum operating temperature,  
the air conditioner may not work properly.  
MODEL  
PA1-12R-32  
PA1-14R-32  
Cooling Capacity  
Heating Capacity  
12,000 BTU/Hr  
12,500 BTU/Hr  
14,000 BTU/Hr  
14,500 BTU/Hr  
Dehumidifying Capacity  
Air Purifier Capacity  
63 pts/day  
63 pts/day  
Removes 99.97% Microns  
1387 Watts  
Removes 99.97% Microns  
1485 watts  
Cooling  
Heating  
Power Consumption  
1180 Watts  
1200 Watts  
Air Flow Volume  
Power Source  
265 CFM  
115 V / 60 HZ  
12.7 A  
265 CFM  
115 V / 60 HZ  
13.6 A  
Cooling  
Heating  
Rated Current  
10.8 A  
11 A  
Sound Pressure Level  
Weight  
<50db(A)  
86.9 lbs  
<50db(A)  
86.9 lbs  
Dimensions (WxDxH)  
Refrigerant  
17.87”x14.3”x32.1”  
R22  
17.87”x14.3”x32.1”  
R22  
DISCLAIMER  
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE  
PRESENTATION OF THE MANUFACTURER. SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT  
TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT DIAGRAM (Actual product design may differ slightly from images below)  
FRONT  
A
A. Control panel  
B. Air outlet  
B
F
C. Casters  
D. Power Cord & Plug  
E. Drain Plug  
F. HEPA Air Purifier Storage  
D
E
C
BACK  
D
A. Hot air outlet grill  
C
B
B. Lower air inlet grill  
C. HEPA Air Purifier Holder  
D. HEPA Air Purifier  
A
ACCESSORIES  
Flexible exhaust hose with 2 adapters  
• 3-piece set  
• stretches from 14 1/4” to 60 5/8”  
(36cm to 150cm)  
Adjustable window slider kit  
• 3-piece set  
• adjusts 33 1/2” to 81”  
Drain tube  
Drain pan  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
SELECTING THE LOCATION  
Place the unit in a flat location where the air out-  
lets are not obstructed. Place the unit at least  
20” (50cm) away from a wall or other obstacle.  
MOUNTING THE EXHAUST HOSE  
Slide the square end of the exhaust duct over the  
hot air outlet on the back of the unit.  
The exhaust hose should be kept as short and  
straight as possible. Prevent any sharp bends in  
the exhaust hose, as this will trap hot exhaust air.  
The hot exhaust air can be vented through the  
wall or out a window. If mounting in the wall, the  
height of the hole should be 16 to 50 inches  
(40cm to 130cm).  
Soleus Air does not provide a venting kit for  
through the wall ventilation. Venting through the  
wall requires a custom installation.  
NOTE: The Portable Air Conditioner above may differ from the unit described in this manual. The above directions and images  
show general directions for all Soleus Air single hose portable air conditioners.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
LCDI POWER CORD AND PLUG  
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and  
plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord  
with no termination on the load side and a LCDI attachment plug on the line side.  
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the  
nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.  
The cord will remain de-energized until the devise has been manually reset. This is intended to reduce the risk  
of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must  
be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed  
metal.  
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:  
1. Plug power cord into wall outlet  
2. Press TEST Button, circuit should trip, cutting power to the air conditioner  
3. Press RESET button for use  
If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the air  
conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting  
recommendations.  
RESET  
TEST  
WARNING:  
1. DO NOT press the TEST button while the air conditioner is operating.  
2. The TEST and RESET buttons should not be used as ONand OFFswitches.  
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.  
4. The cord and plug are intended for indoor use only.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
WINDOW KIT INSTALLATION  
WINDOW KIT INSTALLATION  
The window kit is designed to fit into most standard  
vertical and horizontal windows, as well as some  
sliding glass doors. However, it may be necessary to  
modify some aspects of the installation process for  
certain window types.  
Open the window or sliding door and adjust the  
length of the window kit to fit the opening. If  
the window kit is not long enough, connect the  
extra window kit panel to fit the opening. Mark  
and cut down a single panel of the window kit  
if necessary.  
Window Slider Kit  
Minimum: 33 1/2”  
Maximum: 81”  
Place the window kit between the window and the  
window frame as shown in the images to the  
right. Close the window onto the window kit to  
form a tight seal.  
Attach the exhaust duct adapter to the window kit.  
Tabs located on the adapter will lock into  
place securing the adapter to the window kit.  
Window Slider Kit  
Minimum: 33 1/2”  
Maximum: 81”  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
WINDOW KIT INSTALLATION (cont’d)  
NOTE: The Portable Air Conditioner above may differ from the unit described in this manual. The above directions and images  
show general directions for all Soleus Air single hose portable air conditioners.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS  
CONTROL PANEL & MULTI-COLOR DISPLAY  
MULTI-COLOR DISPLAY  
AIR PURIFIER  
AUTO  
A/C  
DEHUM.  
FAN  
HEATER  
TIMER ON  
TIMER OFF  
FAN SPEED  
TEMP AND  
TIMER  
INDICATOR  
OSCILLATION ON/  
BUCKET FULL COMPRESSOR ON  
SLEEP MODE ON  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
CONTROL PANEL BUTTONS (Refer to the images on page 9)  
1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER  
button once more to turn the unit off.  
2) Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Auto mode,  
Air Conditioner, Dehumidifier, Fan only, and Heater mode. Air Purifier Mode is a separate function, see  
page 13 for Air Purifier Operation.  
3) Fan Speed Control - Press the SPEED Button to cycle through the different fan speeds: High, Me-  
dium, and low. The fan speed can be visually distinguished by the speed of the fan icon on the front panel.  
There is an additional auto speed setting that is enabled in only heating and cooling modes. This speed is  
next setting after low when pressing the speed control button. The speeds will cycle through in this order:  
Low, Medium, High, Auto. Each change in speed will be associated with a “beep” sound from the unit.  
4) Temperature - Select the desired temperature by pressing either or key when using the unit in  
cooling or heating mode. The temperature indicator flashes to display the desired temperature setting. After  
the temperature is set, the unit will display this temperature setting until it is changed by the user. The  
Multi-color display shows temperature in Celsius or Fahrenheit. Pressing the °C/°F button will change the  
temperature select between °C and °F.  
5) Timer & Time+- To program the auto off timer, press the TIMER button until the display shows a flash-  
ing  
when the unit is on. Press the or buttons to change the clock to the desired time for the  
unit to automatically turn off. To program the auto on timer, press the TIMER button when the unit is off.  
Press the or buttons to change the clock to the desired time for the unit to automatically turn on. You  
can also press the TIME+ to increase the operating time. The timer can be programmed while the unit is on  
or off. Once the timer is programmed the timer icon will stop flashing and remain lit. It is suggested to use  
the remote control for a more full featured clock timer function (1-12 AM/PM) .  
NOTE: The timer will also remember your settings when it is set. If you set the timer while in Air Condition-  
ing mode, the timer will automatically turn the unit on and off in air conditioning mode according to the de-  
sired programmed times. The timer will also remember the temperature settings, fan speed, and oscillation set-  
ting. The timer works when the unit is in Air Conditioner mode, Heating mode, Dehumidifier mode, Fan  
mode, Auto mode, and Air Purifier Mode (see page 13 for Air Purifier Mode).  
OPERATING THE UNIT USING THE CONTROL PANEL  
Air Conditioner Mode  
1) Install the exhaust hoses and window kit properly (see pages 5, 7 & 8).  
2) Plug the Power Cord into an electrical outlet.  
3) Turn on the unit by pressing the POWER button on the control panel.  
4) Press the Mode button until the “  
” icon appears on the Multi-color display  
5) Press the or buttons until the desired room temperature appears on the control panel  
display. The temperature ranges from 61°F - 88 °F (16 °C - 31 °C).  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6) Select the desired fan speed by pressing the SPEED button.  
NOTE: During hot days, the unit will cool the room most efficiently by setting the temperature at the lowest  
setting and the fan speed on high. Reducing the length of the exhaust duct, insulating the exhaust hose and  
window kit, and keeping direct sunlight to a minimum will also improve the cooling efficiency.  
NOTE: When the unit is running on cooling mode, the exhaust hoses are required and must be  
vented outside using the supplied window kit.  
Dehumidifier Mode  
1) Install the exhaust hoses and window kit properly (see pages 5, 7 & 8).  
2) Plug the Power Cord into an electrical outlet.  
3) Turn on the unit by pressing the POWER Button on the control panel.  
4) Press the MODE button until the “  
” appears on the control panel display.  
NOTE: The unit operates at low fan speed during dehumidifier mode. The unit cools room slightly during  
the dehumidification. Keep the windows and doors closed to aid the effectiveness of the unit in removing the  
moisture from the room.  
NOTE: When the unit is running on dehumidifier mode, the exhaust hoses are required and must  
be vented outside using the supplied window kit.  
NOTE: The unit will not perform in dehumidifier mode when the room temperature is lower than 61°F .  
Fan Mode  
1) Plug the Power Cord into an electrical outlet.  
2) Turn on the unit by pressing the POWER button on the control panel.  
3) Press the MODE button until the “  
” icon appears on the control panel display.  
4) Select the fan speed by pressing the SPEED button.  
5) To circulate more air, press the SWING button on the remote control. The louvers will oscillate in our  
exclusive WAVEFLO® pattern which moves the louvers up and down to increase air circulation.  
NOTE: It is not necessary for the exhaust hoses and window kit to be installed to operate the unit in fan mode.  
Heating Mode  
1) Install the exhaust hoses and window kit properly (see pages 5, 7 & 8).  
2) Plug the Power Cord into an electrical outlet.  
3) Turn on the unit by pressing the POWER button on the control panel.  
4) Press the MODE button until the “  
“ icon appears on the control panel display.  
5) Press the or buttons until the desired room temperature appears on the control panel display. The  
temperature ranges from 61°F - 88 °F (16 °C - 31 °C).  
6) Select the fan speed by pressing the SPEED button. It is recommended to set the fan speed to low.  
NOTE: When heat mode is selected, the unit will shut down for 3-5 minutes, then start in heating mode.  
NOTE: When the unit is running on heating mode, the exhaust hoses are required and must be  
vented outside using the supplied window kit.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Auto Mode  
1) Install the exhaust hoses and window kit properly (see pages 7 & 8).  
2) Plug the Power Cord into an electrical outlet.  
3) Turn on the unit by pressing the POWER button on the control panel.  
4) Press the MODE button until the “  
” icon appears on the control panel display. Select the fan speed  
by pressing the FAN SPEED button.  
NOTE: During AUTO mode, the unit operates in Heating mode when the room temperature is below 68 °F,  
Dehumidifier mode when the room temperature is between 68 °F to 80 °F. And Air Conditioner mode when  
the room temperature is above 80 °F.  
Sleep Mode (This mode can only be selected when using the Remote control )  
1) To set Sleep mode, make sure the unit is in Air Conditioner mode.  
2) Press the SLEEP Button on the remote control. The “  
” icon appears on the control panel display.  
3) When in SLEEP mode, the fan will run on low to keep fan noise at a minimum.  
4) When in Air Conditioner mode, the temperature setting will gradually increase to 2°F above the original set  
temperature for 6 hours. After 6 hours the temperature setting will return to the set temperature.  
5) When in Heating mode, the temperature setting will gradually decrease to 2°F below the original set tem-  
perature for 6 hours. After 6 hours, the temperature setting will return to the set temperature.  
6) When in Dehumidifier mode, the temperature will not change when Sleep mode is selected.  
Air Purifier Mode - See Page 13  
Compressor Indicator  
The  
icon will light up on the control panel display when the compressor turns on. The  
icon will  
turn off when the compressor shuts off.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AIR PURIFIER FUNCTION  
This portable air conditioner is equipped with a HEPA air purification mode. This mode is only available when  
the HEPA air filter has been inserted into the Air Filter Holder. Please note, when the air filter is inserted into  
the air cleaner, the unit will ONLY operate in air purifier mode. All other modes are not available when this  
mode is selected.  
To Operate Air Purifier Mode:  
1. Disconnect the exhaust hose from the back of the air conditioner.  
2. Remove the HEPA air filter from the storage compartment on the unit and the plastic packaging.  
3. Remove the Air Filter Holder located on the back of the unit.  
4. Place the air filter inside the Holder. Make sure the air filter is placed on top of the black plastic particulate  
filter located inside the holder.  
5. Once the air filter is installed, replace the Air Filter Holder on the back of the unit.  
6. Turn the unit on by pressing either the POWER button (on the remote or control panel) or the PURIFY  
button on the control panel. The  
mode is selected.  
icon will light up on the multi-color display when the air purifier  
7. Once the unit is in Air Purifier Mode, all the other functions will be disabled except the SWING, Fan  
Speed, and TIMER functions (see page 15 for the TIMER function).  
8. To operate the unit in A/C, fan, heater, or dehumidifier mode, remove the air filter from the Air Filter  
Holder and place the holder (with the particulate filter installed) in the back of the unit.  
9. When not using the HEPA air filter, place it in the Air Filter Storage located on the front of the unit.  
Replacing the HEPA Filter: When the HEPA filter needs to be replaced the  
icon will flash on and off  
on the display panel when in the unit is operating in Air Purifier Mode.  
HEPA AIR FILTER  
HEPA Air  
Filter Holder  
HEPA Air  
Filter Storage  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING THE UNIT USING THE REMOTE CONTROL  
REMOTE CONTROL  
LCD DISPLAY  
MODE BUTTON  
FAN SPEED  
POWER BUTTON  
TEMP SETTING  
TIMER ON  
SWING (LOUVER  
OSCILLATION)  
SLEEP BUTTON  
TIMER OFF  
MINUTE SELECTER  
HOUR SELECTER  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REMOTE CONTROL OPERATING INSTRUCTIONS  
1) Power On and Off - Press the POWER (I/O) button on to turn the unit on or off When you press the  
POWER button (when turning the unit on) the upper right square on the remote control LCD Display will  
light up. When in Air Conditioner, Heating, and Auto mode, the selected temperature will appear on the  
remote control display. When the unit is in Fan mode and Dehumidifier mode you will see the “- -” icon  
instead of the set temperature. This shows that temperature selection is not available when the unit is in  
Fan or Dehumidifier mode.  
2) Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Auto, Air  
Conditioner, Dehumidifier, Fan only, and Heater mode. The upper left square on the Remote control dis-  
play will light up showing which mode is selected. In Air Conditioner mode the display will show  
COOLING”, in Heating mode the display will show “HEAT”, in Dehumidifier mode the display will  
show “DRY”, in Fan mode the display will show “FAN”, and in Auto mode the display will show  
AUTO”.  
3) Fan Speed - Press the FAN speed button to cycle through low, medium, and high fan speeds. The dis-  
play on the remote control will show LOW, MED, & HIGH under the “SPEED” label on the remote con-  
trol LCD display. There is an additional auto speed setting that is enabled in only heating and cooling  
modes. This speed is next setting after low when pressing the FAN speed button on the remote control.  
The speeds will cycle through in this order: High, Medium, Low, Auto. Each change in speed will be as-  
sociated with a “beep” sound from the unit. The remote control will not display “AUTO” under the speed  
label. Once Auto fan speed is selected the unit will beep and there will not be a fan speed displayed on the  
remote control.  
4) Temperature Setting - When the unit is in Air Conditioner or Heating mode you can select your desired  
temperature. Press the or to select your desired temperature setting. The temperature on the LCD dis-  
play on the remote control will increase or decrease accordingly. Pressing the and buttons simultane-  
ously will change the temperature select between °F and °C.  
5) SLEEP MODE - See “SLEEP MODE” on page 12.  
6) SWING - To turn on the exclusive WAVEFLO® oscillation, press the SWING button on the remote  
control. Once you press SWING, the louvers on the unit will oscillate up and down. The bottom left  
square of the remote control display will show a line with an arrow at each end when WAVEFLO®  
oscillation (SWING) is selected.  
7) TIMER - To program the timer, first press the T-ON button. Once T-ON is pressed the auto-on timer will  
blink in the bottom right rectangle of the remote control display. Press the MIN and HOUR buttons to  
change the clock to the desired time for the unit to automatically turn on. The minutes will increase by 10  
with each press of the MIN button and the hours will increase by 1 with each press of the HOUR button.  
Press the T-OFF button and the remote control display will flash the desired auto-off timer. Press the MIN  
and HOUR buttons to change the clock to the desired time for the unit to automatically turn off. The timer  
is set when the auto-off time stops flashing and the words “ON” and “OFF” are displayed next to the time.  
8) CLOCK - To set the clock on the remote control, hold down either the MIN or HOUR button until the  
displayed time flashes on the remote control display. Change the minutes by pressing the MIN button and  
change the hours by pressing the HOUR button.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Emergency Condensate Holding Tank  
When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to  
evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emergency  
condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automatically shut  
off and the “  
” will appear on the control panel display. To empty the condensate tank, unscrew the screw  
plug at the bottom right side (when facing the front) of the unit. You will need a small pan, approximately 1”  
high to catch the water coming out of the condensate tank. Once the condensate tank is drained, the unit will  
begin working within a few minutes. The emergency condensate tank holds approximately 1.5 Liters of water.  
Another option is to purchase a small hose from a hardware store that can fit around the 5/8” drain plug on the  
back of the unit and drain the unit into a gravity drain or larger pan for continuous drainage.  
To resume operation quickly, empty the water container according to the following steps:  
1. Turn the unit off. Do not move the unit when the water container is full.  
2. Place the drain pan accessory under the drainage port at the back of the unit.  
3. Remove the screw plug from the drain hole. The condensate water will drain out automatically. When the  
drain pan is full, screw the screw plug back onto the drainage hole to stop the water flow. Empty the drain  
pan. Repeat until all the water is emptied.  
Once the water container has been emptied, screw the plug back onto the drain hole. Do not allow the  
water to drip continuously into the drain pan, as it might easily overflow.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to  
performing any maintenance on the unit.  
Clean or replace particulate air filter (Black Mesh Filter) - If the air filter is blocked with a dust, the air-  
flow volume may reduce. It is recommended to clean the filter once every two weeks or as needed.  
1) Remove the filter from the filter compartment on the back of the unit.  
2) Wash the air filter by immersing it gently into warm water with a neutral detergent. Rinse the filter  
and dry it thoroughly out of sunlight.  
3) Slide the filter back into the filter compartment after it is thoroughly dried.  
4) If the filter is torn or unusable, order a new filter by calling the customer service number on the  
warranty page of this manual.  
Clean the unit Housing  
1) Keep the unit from being exposed directly to the sun to prevent color fading.  
2) Clean the surface with a damp cloth and dry it with a soft towel.  
Storing the Unit for an Extended Period of Time or Transporting the unit  
1) Empty any excess water by unplugging the water drainage stop in the back of the unit (located at  
the bottom).  
2) Unplug the unit.  
3) The unit should be stored in a cool dry place.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
One Year Limited Warranty  
Soleus International Inc. warrants the accompanying Soleus Air Portable Air Conditioner to be free of defects in mate-  
rial and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the  
date of original retail purchase in the United States.  
If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of  
charge within a reasonable time after the unit is returned during the warranty period.  
As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a  
copy of the original purchase invoice.  
THIS WARRANTY DOES NOT COVER:  
Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in  
material or workmanship.  
Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions  
in the instructions.  
Damage to the finish of the case, or other appearance parts caused by wear.  
Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna-  
tional Inc.  
Freight and Insurance cost for the warranty service.  
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO  
ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY. SOLEUS INTERNATIONAL INC.  
DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT  
SHALL SOLEUS INTERNATIONAL INC’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR  
BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT.  
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, sal-  
vaged, or refurbished products.  
As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow  
limitation on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you  
specific legal rights, and you may also have other rights that vary from state to state.  
For Technical Support and Warranty Service  
Please Call (888) 876-5387  
Or Write To:  
Soleus International Inc.  
20035 E. Walnut Dr. N.  
City of Industry, CA 91789  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Air Cleaner FP A28C User Manual
Snapper Tiller 1691277 User Manual
Sony Clock Radio ICF CD833 User Manual
Sony Home Security System DCR TRV130E User Manual
Sony MP3 Player E205 User Manual
Sony Projection Television KL 40WA1K User Manual
Sony Projector VPL CX3 User Manual
Specialized Cyclometer CylcoComputer User Manual
Sunbeam Microwave Oven SMW759 User Manual
T+A Elektroakustik CD Player K1 CD RECEIVER User Manual