Soleus Air Air Conditioner KFHHP 22 ID User Manual

Wall Mounted Mini Split  
Heat Pump  
Air Conditioner  
OPERATING AND INSTALLATION MANUAL  
Model: KFHHP-22-ID / KFHHP-22-OD  
Indoor Unit.  
Outdoor Unit.  
Thank you for selecting Soleus Air. To ensure proper  
operation, please read this manual and keep it for  
future reference.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation and Maintenance  
Instructions before Use  
Carefully read the following instructions before use  
Warning  
Do not use flammable liquids on or near this air Touching metal parts after removing filter can  
conditioner.  
cause an electric shock.  
Do not use for long periods of time if the  
Don’t operate the air conditioner with web  
humidity is high. Condensation may be present.  
hands. It can cause an electric shock.  
Do not insert your hands or any other object into If your air conditioner malfunctions,  
the air intake or outlets.  
discontinue use and call your authorized dealer.  
- 1 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instructions before Use  
Don’t attempt to repair the air conditioner by  
yourself. There are no user replaceable parts.  
Please contact your authorized dealer.  
Always use new batteries in your remote.  
Never mix batteries.  
Be sure to turn the power off when not using the Never store flammable liquids near your air  
air conditioner for a long time. conditioner.  
The condensing unit should be Don’t step on the top of the  
Don’t block the air intake or  
outlet vents of both the outdoor  
and indoor unit. It can decrease  
the air conditioning capacity or  
cause a malfunction.  
securely mounted to avoid  
damage.  
outdoor unit.  
- 2 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Description of Air Conditioner Components  
Air intake  
On/Off Switch  
Air outlet  
On/Off Switch  
Signal Sensor  
Connecting Pipe /  
Line set  
- 3 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control Operation  
Function-Remote control  
Note:  
Don't drop the remote control.  
Don't place the remote control in a location exposed to direct sunlight.  
When the unit is restarted after stopped, it will automatically resume its last running mode, and the  
outdoor unit will start there after.  
MODE Button:  
TEMP+ TEMP- Button:  
When the unit is  
turned on, press this  
button. The AUTO,  
COOL, DRY, FAN or  
HEAT mode can then  
be selected.  
Under the COOL, DRY,  
FAN or HEAT mode, press  
these two buttons could set  
the temperature, the temp.  
setting range is 60.8°F  
-86°F, the temp. can be  
memorized under each  
mode.  
FAN SPEED Button:  
When the unit starts up,  
under the AUTO, COOL,  
FAN or HEAT mode, press  
this button and select Auto  
fan, Low fan, Middle fan,  
High fan. At DRY mode,  
the fan speed runs at Low  
fan speed. The FAN  
CLOCK Button:  
When pressing this button  
once, the icon of CLOCK  
will flash, and can be  
adjusted. At CLOCK  
adjustment, press the  
TIME+ once, the ones  
placed on the minute will  
be increased 1, and  
SPEED can be memorized  
under various modes.  
continuously press 1 sec  
above, the tens place on  
the minute will be  
increased 1 in every half  
second. When pressing  
the TIME-, the ones  
SLEEP Button:  
placed on the minute will  
be decreased 1, and  
continuously press 1 sec  
above, the tens place will  
be decreased 1 in every  
half second. After  
Under COOL, DRY &  
HEAT mode, press the  
button once to start the  
SLEEP function, when  
pressed again, it will stop.  
adjusting please press the  
CLOCK button again for  
confirming.  
- 4 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control Operation (Continued)  
Liquid Crystal Display.  
It shows all set contents.  
SWING Button:  
ON/OFF Button  
Press once to have louvers  
swing [oscillate]. Press  
twice in one second the  
panel light will turn on.  
Press twice again and the  
light will turn off.  
Press ON.  
Press OFF.  
T-ON Button.  
When pressing this button  
once, enter into T-ON  
setting, the icon of T-ON  
flash, every press of  
T-OFF Button  
TIME+, the time of T-ON  
will be increased 1min.  
When continuously press 1  
sec above, the tens placed  
on minute will be increased  
1, every press of TIME-  
will be decreased 1 minute,  
when continuously press 1  
sec above, the tens placed  
on minute will be decrease  
1 in every half second, and  
it goes round with 12 hours.  
Press this button once to  
enter into T-OFF setting,  
the icon of T-OFF will  
flash, the T-OFF button  
is available in ON or  
OFF mode, the setting  
method is the same with  
T-ON.  
CANCEL Button  
Pressing this button will  
cancel timer.  
TIME+ TIME- Button  
Function instruction please  
refer to T-ON button,  
T-OFF button, CLOCK  
button.  
- 5 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control Operation (Continued)  
The General Procedure:  
1. Press ON/OFF button to start the unit.  
2. Press MODE button to select the suitable operation mode.  
3. Press SWING button to swing. It will stop when pressed again.  
4. Press FAN button to set desired fan speed.  
5. Press +/- button to set desired temperature.  
The Selected Procedure:  
6. Press SLEEP button to set timer.  
7. Press ON/OFF button to set desired temperature.  
Note:  
In AUTO mode, the unit will automatically adjust its running modes according to the room  
temperature.  
How to Insert Batteries  
The remote control uses two AAA batteries.  
1. Remove the cover from the back of the remote control and insert two new batteries.  
2. Re-attach the cover.  
Note:  
Don’t mix new and used or different types of batteries.  
Remove batteries when the remote control is not in use for a long time.  
Keep remote at least 3.28 feet from TV’s and other electronic devices.  
When the wireless remote control is lost or broken, please use the manual switch,  
It will start in AUTO mode, the temperature setting and fan speed cannot  
be changed. Please use a ball point pen or similar device to operate switch.  
Turn on the unit: By pressing the Manual Switch the unit will start in AUTO automatically.  
The microcomputer will adjust to the indoor temperature by selecting (COOL, HEAT, FAN), in order to  
achieve a comfortable condition.  
Turn off the unit: When unit is running, press the manual switch STOP button, the unit will stop running.  
- 6 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Notices  
Select the most comfortable temperature.  
The airflow direction can be adjusted.  
At operating, adjust the vertical airflow direction  
by adjusting the louvers of upward/downward  
direction. And then, hold two ends of left and  
right louver to adjust the horizontal airflow.  
Don’t leave windows and doors open for a long Splashing water on the air conditioner can  
time while operating the air conditioner.  
cause an electric shock and malfunction.  
It can decrease the air conditioning efficiency.  
Don’t use the air conditioner for other purposes,  
such as drying clothes, preserving foods, etc.  
- 7 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Care and Maintenance  
CAUTION:  
Turn power off and pull out the power cord before cleaning air conditioner.  
Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause  
an electric shock.  
Volatile Liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units  
with a dry soft cloth, or a cloth slightly moistened with water or cleanser.)  
Take down the surface panel and clean it (Take it down before cleaning)  
1. Pull along the direction of  
2. Washing  
arrows to take down surface  
panel.  
Wipe with a cloth slightly  
moistened with water or  
cleaner then dry it.  
Note: Never use water above  
113°F to wash the panel, or it  
could cause deformation or  
discoloration.  
3. Install surface panel.  
Install the supports (those are on  
two ends of surface panel) into  
the supporting slots then cover  
the surface panel and clasp it.  
Cleaning the Air Filters (Recommended once every three months)  
The air filters should be cleaned more frequently in dusty conditions.  
1. Take down the air filter  
Open the surface panel, hold the tab of air filter  
and raise it slightly, and then take it out along the  
direction of arrows (See the right figure).  
2. Cleaning  
To clear the dust adhering to the filters, you can  
either use a vacuum cleaner, or wash them with  
water and dry it in the shade (See the right figure).  
Note: Never use water above 113°F to wash the filters, or it  
could cause deformation or discoloration. Never parch it by  
fire, or it could cause a fire or deformation.  
- 8 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Care and Maintenance (Continued)  
3. Reinsert the filters  
Reinsert the filters along the direction of arrow, then  
cover the surface panel and clasp it.  
Check before Use  
1. Be sure that nothing obstructs the air outlet and  
intake vents.  
2. Verify that the unit is properly grounded.  
3. Always use new batteries.  
4. Verify condenser is properly mounted.  
Maintain after Use  
1. Clean filters and other parts.  
2. Turn main power off.  
3. Clean dust from the outdoor unit.  
Trouble Shooting  
Warning: Don’t attempt to repair the air conditioner by yourself; it can cause an electric shock or fire.  
Please check the following items before calling your service technician.  
Problem  
Trouble Shooting  
Won’t start immediately  
Once the air conditioner is stopped, it will not  
operate until the time delay of 3 minutes has  
passed.  
when the air conditioner is  
restarted.  
There’s unusual odor blowing  
from the outlet after operation  
is started.  
This is caused by the odors in the room.  
- 9 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble Shooting  
Problem  
Trouble Shooting  
Sound of water flow can be heard during operation.  
This is caused by the refrigerant flowing inside  
the unit.  
Mist is emitted during cooling operation.  
Because the air of the room is cooled down  
rapidly.  
Creaking noise can be heard when start or stop the unit.  
This is caused by the expansion of plastic due to  
the change of temperature.  
Air conditioner does not operate at all.  
Has the power been shut down?  
Is the leakage protection switch in operation?  
Is TIMER ON is operation?  
Cooling (Heating) efficiency is not good.  
Is SET TEMP. suitable?  
Is air inlet or outlet obstructed?  
Are air filters dirty?  
Are the windows and door closed?  
Is indoor fan speed set at low speed?  
Is there any other hear source in your room?  
Remote control can’t be used when the air  
conditioner is disturbed or changing its  
functions frequently.  
Remote control is not operating  
Is the remote control out of effective to the  
indoor unit? Are there any obstruction  
between the remote control and the signal  
receptor?  
Replace the worn batteries of remote control  
is the voltage of the batteries is not sufficient.  
- 10 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications and Technical Data  
Model  
Function  
KFHHP-22-ID / KFHHP-22-OD  
Heating and Cooling  
22000 / 6450 (2250-7000)  
24200 / 7100 (1650-8500)  
208-230V~  
Cooling capacity(BTU/hr) & (Watts)  
Heating capacity(BTU/hr) & (Watts)  
Rated voltage  
Rated Frequency  
60Hz  
Cooling/Heating rated current(A)  
Cooling/Heating rated power(W)  
Cooling/Heating power input(W)  
SEER  
10.0/9.3  
3300/3200  
2280/2250  
14  
EER/COP(W/W)  
HSPF  
8.4  
Recycling Air Volumem3/h  
Factory Charge 410A (lbs.)*  
Noise (Indoor/Outdoor) dBA  
1100/1000/900  
R410A 5.3 lbs  
50/59  
Maximum Vertical  
Maximum Length  
Height  
Differential  
Net Weight (Indoor/Outdoor) (lbs)  
38.6/138.9  
Indoor unit 46.38” ×8.98” ×12.83”  
Outdoor unit37.40” ×16.54” ×33.07”  
Dimensions (Indoor/Outdoor)  
(WxDxH)(inch)  
Connection Pipe:  
Length (ft)  
26.25  
Gas additional charge(oz/ft)  
0.21  
Liquid Pipe (mm)  
Φ9.52(3/8”)  
Φ16(5/8”)  
32.81  
Outer Diameter  
Max Distance  
Gas Pipe (mm)  
Height (ft)  
Length (ft)  
65.62  
1. All above are tested and certified to ETL specification.  
2. All above could be changed without notice; the latest specifications are on the nameplate of your air  
conditioner.  
When the unit is restarded after it stopping, it can automatically resume the last running mode, and the outdoor  
unit starts later.  
Working temperature range  
Indoor side DB/WB(°F) Outdoor side DB/WB(°F)  
Maximum cooling  
Minimum cooling  
Maximum heating  
Minimum heating  
90 / 74  
70 / 59  
81 / --  
68 / --  
109 / 79  
70 / --  
75 / 64  
23 / 21  
- 11 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Services  
Installation Diagram  
Important Notes  
The installation must be done by trained and  
qualified service personnel.  
- 12 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Location  
Indoor Unit  
1. The inlet and outlet should not be covered so that the outflow air can reach all parts of the room.  
2. Install in a location from which the condensation water can be drained out conveniently.  
3. Avoid a location where there is heat source, steam or flammable gas.  
4. Install in a location where is strong enough to withstand the full weight and vibration of the unit.  
5. Be sure that the installation conforms to the installation dimension diagram.  
6. Be sure to leave enough space to allow access for routine maintenance. The height of the installed  
location should be 90.55 inch or more away from the floor.  
7. Install in a location where is 3.28 feet or more away from other electric appliances such as  
television, audio devices, etc.  
8. Select a location where is easy to remove and clean the filter.  
Outdoor Unit  
1. Select a location from which noise and outflow air emitted by unit will not inconvenience  
neighbors.  
2. Select a location where there should be sufficient ventilation.  
3. The inlet and outlet should not be covered.  
4. The location should be able to withstand the full weight and vibration of the outdoor unit and  
permit safe installation.  
5. There should be flammable gas or corrosive gas leaks.  
6. Be sure that the installation conforms to the installation dimension diagram.  
- 13 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Install the rear panel  
1. Always mount the rear panel horizontally. Because the mouth of drainage pipe is at the left side  
and the left side of the rear panel is better to adjust  
slightly lower.  
2. Fix the rear panel on the selected location with  
screws supplied with the unit.  
3. Be sure that the rear panel has been fixed firmly  
enough to withstand the weight of an adult of  
132.3 lbs; furthermore, the weight should be evenly  
shared by each screw.  
Install the piping hole  
1. Make the piping hole Φ65in the wall at a slight downward slant to the outdoor side. (Shown  
in Fig.1)  
2. Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring from being  
damaged when passing through the hole.  
Install the drainage hose  
1. For well draining, the drain hose should be placed at a  
downward slant.  
2. Do not wrench or bend the drain hose or flood its end by water.  
3. The extended drainage pipe in the room should be wrapped with  
the insulating materials.  
Install the connection pipes  
Connect the connection pipes with the relevant union pipes of the indoor unit and tighten the flare nut  
of the connection pipes (Shown in P19 “Install the connection pipes”).  
NOTE:  
Connect the connection pipes with the indoor unit firstly and the outdoor unit secondly.  
Be careful in bending the connection pipes, or you will damage the pipes.  
If the tightening torque is too great is tightening the flare nuts leakage will happen.  
Electric wiring and electric wiring between indoor and  
outdoor unit  
1. The power supply should adopt the rated voltage and special circuit.  
2. Wiring must be done by special technician according to local rules, regulations and the manual.  
3. The nut should be tightened and cannot fall off.  
- 14 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Wiring of indoor unit  
Note: The power of indoor unit is supplied by the outdoor. A breaker needs to be installed for safety.  
Operation Procedures:  
1. Open the surface panel.  
2. Open the cover and cover plate of electric  
box. (Right figure)  
3. Remove the receiving window as shown in  
the below left figure.  
4. Wire pipe should be tightened by the fixed nut and the electric box should be fixed as shown in the  
above right figure and the below figure.  
Shield cover (upper) of electric box must be grounded.  
- 15 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Electric Wiring  
Note: Wiring must be done by a certified technician according to the local rules & regulations. The  
connecting wire should be correctly connected to circuit interface. Otherwise, it can cause a fire,  
electricity leakage and so on.  
The diagram is shown as below:  
NOTE:  
1. Wiring should be correctly installed.  
2. Tighten the nut of terminal board to avoid falling off.  
3. Incorrect wiring will cause the unit to malfunction.  
4. Units that are not properly grounded are hazardous and may cause the unit to fail.  
Wire  
Power wire  
of unit min.  
section  
Capacitance of air  
switch  
Grounding min  
section  
Fuse  
(Indoor)  
Fuse  
(Outdoor)  
Model  
KFHHP-22  
30A  
3.15A  
25A  
- 16 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Wiring of Outdoor unit  
Operation Procedures:  
Open the cover of outdoor unit.  
The connecting wire led from the terminal board of indoor unit should be connected correctly.  
The connecting wire should be a little longer so that it can easily maintained.  
NOTE:  
1. Wiring should be correctly installed.  
2. Tighten the nut of terminal board to avoid falling off.  
3. Incorrect wiring will cause the unit to malfunction.  
4. Units that are not properly grounded are hazardous and may cause the unit to fail.  
- 17 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Install the Power Line  
1. Remove the front side plate.  
2. Break through the hole for wires and put on the rubber bushing.  
3. Pull all wires through the rubber bushing.  
4. Remove the wire clamp and connect the end of the power connection cord with screws to the  
wiring terminal board according to the “WIRING DIAGRAM” of the outdoor unit.  
5. Make sure that the wiring has been connected properly.  
6. Tighten the wire with clamp and clasp.  
7. After the wiring crosses through the Connector, tighten the Connector with the fix nut.  
Install the Indoor Unit  
1. When routing the piping and wiring from the left or right side of the indoor unit, cut off the  
tailings from the chassis as necessary (shown in Fig.3).  
Cut off tailing 1 when only power cord is routed.  
Cut off tailing 1 and 2 when connect pipe and power cord are routed.  
2. Wrap the piping and wiring and pull them through the cut-off tailings hole (shown in Fig.4).  
3. Hang the 2 mounting slots of the indoor unit on the upper tabs of the rear panel and check that it  
is securely fastened.  
4. The height of the installed location should be 7.55 feet or more from the floor.  
- 18 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Install the Outdoor Unit  
Install the connection pipe:  
Align the center of the piping flare with the valve.  
Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to  
right figure.  
Note: Exceeding tightening torque will damage the flare nut.  
Tightening Torque Table  
Tightening Torque  
Hex Nut Diameter (mm)  
N.m)  
φ12  
φ16  
50~55  
60~65  
- 19 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Air Purging and Leakage Test  
1. Connect charging hose of manifold value to  
charging end of low pressure valve (both  
high/low pressure valves must be tightly shut).  
2. Connect joint of charging hose to vacuum pump.  
3. Fully open handle of Lo manifold valve.  
4. Open the vacuum pump to evacuate. At the  
beginning, slightly loosen joint nut of low  
pressure valve to check if there is air coming  
inside. (Valve of vacuum pump changes from  
negative to 0) Then tighten this nut.  
5. After finishing evacuation, shut Lo handle of  
manifold valve to stop the vacuum pump.  
(1) Keep evacuating for 15 minutes and make sure the reading of multi-meter is -1.0 x 14.5 PSI  
(-76cmHg).  
6. Fully open high/low pressure valves.  
7. Remove charging hose from charging end of low pressure valve.  
8. Tighten bonnet of low-pressure valve.  
- 20 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Test Operation and Check after Installation  
Test Operation  
1. Test Operation  
(1) Do not switch on power before installation is finished  
completely.  
(2) Electric wiring must be connected correctly and securely  
(3) Cut-off valves of the connection pipes should be opened.  
(4) All the impurities such as scraps must be cleared from the  
unit.  
2. Test Operation Method  
(1) Switch on power and press “ON/OFF” button on the remote control to run the air conditioner.  
(2) Press “MODE” button and check the operation condition of COOL, HEAT, SWING mode  
and so forth.  
If Wireless remote control is lost, open the surface panel and operate as following:  
a. When turning it to Auto position, unit will run in Auto mode, if there is remote control signal, it will run at  
the remote control signal.  
b. When turning it to Test position, the main unit will enter into Cool mode, indoor fan will run at high fan  
speed, if there is remote control signal, main unit will run at the remote control signal.  
c. When turning it to Run position, the main unit will run at received remote control order.  
d. When turning it to Stop position, the unit will stop running.  
Check after Installation  
Items to be checked  
Has it been properly mounted?  
Possible Malfunction  
The unit may drop, shake or emit noise.  
Have you done the refrigerant leakage test?  
Does the unit drain well?  
It may cause insufficient cooling (heating) capacity.  
It may cause condensation and dripping.  
Is the voltage in accordance with the rated voltage  
marked on the nameplate?  
Is the electric wiring and piping connection  
installed correctly and securely?  
It may cause electric malfunction or damage the part.  
It may cause electric malfunction or damage the unit.  
Has the unit been connected to secure grounding  
connection?  
It may cause electrical leakage.  
Has the inlet and outlet been insulated?  
It may cause insufficient cooling (heating) capacity.  
The refrigerant capacity is not accurate.  
Has the length of connection pipes and refrigerant  
capacity been recorded?  
- 21 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Schematic Diagram  
Electrical Schematic Diagram (Indoor Unit)  
Please Help Insert Diagram in here.  
- 22 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Schematic Diagram (Outdoor Unit)  
Please Help Insert Diagram in here.  
- 23 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
Soleus International Inc. warrants the accompanying Soleus Air Wall Mounted Mini Split Heat Pump Air  
Conditioner (KFHHP-22-ID/KFHHP-22-OD) to be free of defects in material and workmanship for the  
applications specified in its operation instruction for the period of parts specified below.  
5 YEARS FOR COMPRESSOR  
1 YEAR FOR OTHER COMPONENTS  
This warranty shall not apply to broken or marred cabinets, accessories, knobs, filters or routine maintenance.  
This warranty does not apply to uncrating, setup, installation, removal of the product for repair or  
reinstallation of the product after repair.  
This warranty does not apply to repairs or replacements necessitated by any cause beyond the control of  
Soleus International including, but not limited to, any malfunction, defect or failure caused by or resulting  
from unauthorized service or parts, improper maintenance, operation contrary to furnished instructions,  
shipping or transit accidents, modification or repair by the user, abuse, misuse, neglect, accident, incorrect  
power line voltage, fire, flood or other Acts of God, or normal wear and tear.  
Warranty service must be performed by a qualified HVAC contractor. Soleus maintains a centralized service  
network to provide parts and assist in resolving service problems if difficulties are encountered. Soleus agrees  
to provide service information, sell repair parts and reimburse the dealer /serviceman for parts in accordance  
with Soleus International’s Policies and Procedures.  
SOLEUS INTERNATIONAL MAINTAINS THAT ALL WARRANTIES, INCLUDING IMPLIED  
WARRANTY OR MERCHANTABILITY ARE LIMITED TO THE TERMS AND CONDITIONS  
SPECIFIED ABOVE. SOLEUS INTERNATIONAL DISCLAIMS ANY LIBILITY FOR  
CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS  
INTERNATIONAL INC.’S LIABILITY EXCEED THE RETAIL VALUE OF THE AIR  
CONDITIONER.  
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover  
internet sales, used, salvaged, or refurbished products.  
FOR TECHNICAL SUPPORT AND WARRANTY SERVICE  
Soleus International Inc.  
Tel: 1-888-8 SOLEUS  
Monday through Friday, 9:00 AM to 5:00 PM, PST  
- 24 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Microwave Oven R 85ST User Manual
Snapper Lawn Mower 1031 User Manual
Sony Headphones BT101 User Manual
Sony Portable CD Player D E400AN User Manual
Sterling Thermostat 6211 E User Manual
Sunbeam Humidifier 129857 User Manual
Sunrise Medical Stroller Xpress User Manual
SUPER MICRO Computer Computer Hardware SRS42URKSGPUS13 User Manual
Sylvania Digital Photo Frame SDPF1079 User Manual
Tanaka Chainsaw TCS 3401 User Manual