Sierra Products Stove MODEL EF 3800 User Manual

Pellet Heater Repair Manual  
Please familiarize yourself with entire manual before attempting a repair or  
adjustment of the heaters.  
MODEL EF 3800 PELLET HEATER  
MODEL EF 5000 PELLET HEATER  
MODEL EFI 4000 PELLET INSERT  
MODEL EF3801PELLET HEATER  
Sierra Products Inc., 5061 Brooks St., Montclair, CA 91763  
P/N 140154 R1 1/05 rb  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. INTRODUCTION & SERVICE PHILOSOPHY  
Following is a comprehensive service manual which will assist both dealer or service personnel in maintaining and servicing  
the Easyfire Pellet Stoves.  
Before getting into the specifics of service we would like to give an overview of our service philosophy and what we expect of  
dealers when they take on the Easyfire line.  
To become a pellet stove dealer means, by definition, that you will be making a commitment to service. This is an appliance,  
not another wood stove. If you are not prepared to enter into the appliance repair and service business then you should not  
even consider becoming a pellet stove dealer. Pellet stoves for the most part are wonderful heaters that will, with proper  
maintenance, provide years of clean, trouble free burning and quality heat. The simple fact is they have many moving parts,  
unlike a wood stove, and these parts require lubrication and maintenance. Because the pellet technology is new the user  
must be educated and trained as to the proper use and maintenance from season to season to avoid performance problems.  
For these reasons we require our dealers to set up a service department that is dedicated to keeping the customer happy with  
a care free unit. The user must be made aware of his or her responsibilities and what is required to keep the unit working at  
peak performance. The service department and personnel should adhere to the following guidelines:  
1. Service personnel should possess a high degree of mechanical aptitude, good common sense coupled with an  
analytical mind. The ability to read and use electrical schematics, listen to customer complaints politely and determine what  
might be causing the difficulty. The customer needs to feel confident that the service person will be able to detect system  
malfunctions accurately, analyze problems and solve them.  
2. When entering the customer's home the service person should be neat and clean in appearance, have the necessary  
tools and parts required to attend to the problem and share with the customer an explanation of charges and the customer's  
responsibilities in regards to future maintenance. This must be done in such a manner that there is no misunderstanding or ill  
feeling.  
3. Remember, it is the service person who represents your business when in the customer's home. A good impression by  
the service person creates a good impression of your business. The work is expected to be neat and professionally done.  
4. When a customer calls for service they should be greeted with a friendly calming voice, assuring them that the problem  
will be given prompt attention. It is important to get and give accurate, relevant information. The following is an information  
guideline:  
a. Customer name, address and phone number.  
b. Serial number of the stove.  
c. What the customer thinks is wrong.  
d. When did the problem start.  
e. When was the unit last serviced?  
f. When and where was the stove purchased?  
g. Who installed the unit and when?  
Note: At this point the problem can usually be dealt with by phone (90% of pellet stove problems are lack of cleaning).  
5. If you need to schedule a service call remember the following:  
Prioritize calls so that "no heat" calls are taken care of first. Do minor calls next but don't put them off or you will only have an  
angry, upset customer who will cause a lot of grief for you and your business. Stick to your schedule. If you tell a customer  
you will be there tomorrow at 2:00 p.m. Be there at 2:00 p.m. or call well in advance to let them know, their time is valuable  
too. If a part is needed and you don't have it, tell them, and order one as soon as you get back to the store. Give honest  
responses, not creative excuses.  
6. Once on the job the service person must use a systematic approach and think in terms of cause and effect. After some  
experience with the stove you should be able to look at the fire, flame pattern, sounds and smells and detect problems  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
immediately. To obtain this degree of expertise you must acquaint yourself with every component and stove function. Never  
guess!  
TOOLS & SERVICE KIT  
The tools and equipment needed for servicing the Easyfire Pellet Stove are as follows:  
a. Good shop vacuum with blower capabilities.  
b. Set of socket drivers which must include 11/32, 1/2 & 7/16 sockets or nut drivers.  
c. Phillips and plastic coated slot screw drivers  
d. Flashlight  
e. Extension cord with ground  
f. Allen wrench set (long handle)  
g. Wire stripper and cutter  
h. Electrical continuity tester with light or LED  
i. Fully charged 12V Gel Cell Battery at least 30amp  
j. Assorted crimp connectors with crimp tool  
The Easyfire Service Kit which includes:  
a. Fan Motor, Feed Motor  
b. Main Circuit Board  
c. Switch Board (control board and knob)  
d. One each T-1 and T-2 Sensor  
e. Three (3) each fuses, (1A, SB) for rear panel AC Line  
and 5mm fuse (6.3A, SB) for main board 12V line.  
f. Digital read out volt multi meter  
h. One each bridge rectifier  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
EasyFire™ Pellet Heater  
Warranty Replacement Program  
EASYFIRE LIMITED LIFE TIME, THREE, ONE YEAR WARRANTY  
Sierra Products, Inc.(SPI) warrants to the original consumer that this stove will be free of defective materials and workmanship  
for a period as listed below from the date of purchase. This warranty does not extend to any parts damaged through abuse,  
accident, or neglect or warpage due to overfiring; nor does it apply if the stove has been repaired or modified without SPI’s written  
authorization. If the stove proves to be defective in material or workmanship within the warranty period, SPI will, at no charge,  
repair or replace (at its option) any defective parts, if the purchaser ships the parts or the stove, freight prepaid, to SPI or the  
nearest authorized service center. SPI may require the consumer to supply reasonable proof of the stoves purchase date.  
WARRANTY SCHEDULE:  
OUTER BODY - LIMITED LIFETIME, FIREBOX COMPONENTS - THREE YEARS,  
ELECTRIC COMPONENTS - ONE YEAR.  
This warranty is in lieu of any other express warranty. Any implied warranties, including but not limited to any  
implied warrantyofmerchantabilityorfitnessforaparticular purpose shall not extend beyond one year from the date  
of purchase.  
The purchaser's sale and exclusive remedy shall be for the repair or replacement of defective parts, as provided for in this  
warranty. No other remedy (including but not limited to incidental or consequential damages for lost profits, lost sales, injury to  
person or property, or other incidental or consequential loss) shall be available to the purchaser.  
Some states do not allow limitations on howlong an implied warranty lasts and some states do not allow the exclusion or limitation  
of incidental or consequential damages, so the above limitations or exclusions may not apply to you.  
SPI’s warranty obligation and the purchaser's rights under it can be altered only by a subsequent written agreement between SPI  
and the purchaser.  
The remedies provided in this warranty are void unless the attached warranty registration card is received by SPI within 30 days  
from the date of purchase.  
If you have a warranty claim or questions about the performance of your stove, you are requested to contact your dealer. This  
warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  
WARRANTY WORK:  
All warranty work must be authorized by the factory in advance of the repair and an authorization number assigned. A  
warranty claim form must be completed and signed by both the repair person and the customer. All claims must be submitted  
to your distributor, if you are buying products through a distributor. In the event a unit has to be replaced, the warranty claim  
form must be affixed to the unit with a description of the defect. Only the factory can authorize a heater return!  
Any replacement parts required may be obtained from Sierra Products and will require a Purchase Order. Parts will be  
invoiced to the dealer account and credit will be issue upon return to Sierra. All returned parts must be accompanied by a  
warranty claim form. If you have a warranty claim for installing the part, use the same claim form and authorization number.  
Please note... No credit will be issued until a warranty form with an authorization number is received along with the  
defective part.  
AUTHORIZED WARRANTY PAYMENT:  
Sierra Products will credit the distributor/dealer account the sum of sixty five dollars ($65.00) per occurrence and forty cents  
($.40) per mile, maximum one hundred miles round trip.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
EasyFire™ Pellet Heater  
Warranty Claim Form  
Customer Information:  
Unit Information:  
Name:_________________________________  
Address:_______________________________  
City/State/Zip:___________________________  
Phone:________________________________  
Dealer Information:  
RMA Number ____________  
Model Number ___________  
Serial Number _____________  
Date of Purchase _________  
Name:_______________________________  
Address:_____________________________  
City/State/Zip:________________  
Date:__________________  
Mileage:________________  
Serviceman_________________  
Describe Defect:  
_____________________________________________________  
_____________________________________________________  
_____________________________________________________  
_____________________________________________________  
Describe Repair: _____________________________________________________  
_____________________________________________________  
_____________________________________________________  
_____________________________________________________  
Customer Verification:  
I verify that the above repairs were made to my EasyFire Heater and that I am the original owner of the  
above model.  
Customer Signature:________________________________________  
Service Person Verification:  
I verify that the above repairs were made to the above EasyFire Heater.  
Service Person Signature:_______________________________________  
Distributor Authorization:_______________________________________  
P/N 140154 10/07  
Sierra Products Inc. 5061 Brooks St. Montclair, CA 91763  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICE CALLS  
The objective when making a service call is to get the customer up and running as quickly as possible. For this reason the  
best method of attack is to find the problem quickly and isolate the faulty component and swap it out with the good component  
in your dealer service kit. The defective module or part can then be repaired to returned to the factory away from the  
customer's home.  
With this objective in mind the EasyFire troubleshooting can be divided into six (6) general categories:  
1. The fan and feed motors.  
2. The main circuit board.  
3. The switch (control knob) circuit board.  
4. The temperature sensors T-1 and T-2.  
5. The AC power line components, i.e.,  
6. The wiring harness and connectors thereto.  
These six (6) areas represent the areas where problems might occur. They are listed in the order of highest probability,  
based on their history and level of complexity. The design of the electronics has been done with reliability as the highest  
priority, and the components which are under the most electrical or thermal stress are very conservatively rated.  
The main board has been listed second due to the large number of parts, which increases its chances of failure on a  
statistical basis. In practice, however, it should be the most reliable due to the rigorous test procedure each board goes  
through before being installed on the stoves. Because of this mechanical items such as the motors should be suspect first.  
Remember, ninety per cent (90%) of pellet stove failures are due to improper maintenance by the end user! Check the stove  
for cleanliness and routine maintenance before doing any mechanical service work.  
Following is a list of complaints and/or service problems which represent at least ninety five (95% per cent of possible service  
calls:  
1. Stove not running at all.  
2. Feed motor runs, but no fan.  
3. Fan motor runs, but no feed.  
4. Stove runs, but shuts down about 10 minutes after start up.  
5. Stove runs, but keeps shutting down with over-temp (red)  
LED coming on.  
6. Stove runs, but heat output remains at the LOW level, even  
when switch is on HIGH.  
7. Stove does not run on battery or battery does not charge.  
8. Stove runs on FAN position but when switched to LOW, MEDIUM  
or HIGH shuts off immediately.  
9. Stove seems to be running very HIGH or CLEAN mode at all  
times.  
10. Fan speed seems normal for each position, but feed rate  
seems excessive even on LOW.  
Following is a trouble shooting Flow Chart for each of the problems outlined above. If you follow the flow chart carefully each  
of the problems can be solved quickly and easily.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble Shooting Flow Chart #1 - Stove not running at all.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble Shooting Flow Chart #2 - Feed motor runs, but no fan.  
Trouble Shooting Flow Chart #3 - Fan motor runs, but no feed.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble Shooting Flow Chart #4 - Stove runs, but shuts down in 10 minutes (Make sure stove is hot  
enough - 140°F).  
Trouble Shooting Flow Chart #5 - Stove runs, but shuts  
down randomly with over-temp LED On.  
Steady Red = High Temp  
Blinking Red = Blocked Flue  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble Shooting Flow Chart #6 - Stove runs, heat output stays Low, even on High setting.  
Trouble Shooting Flow Chart #7 - Stove will not run on battery or charge battery.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble Shooting Flow Chart #8 - Stove runs in fan only mode, but when turned to Low, Med, or High, it shuts off  
immediately.  
Trouble Shooting Flow Chart #9 - Fan always very high, all  
modes except off.  
Trouble Shooting Flow Chart #10 - Feed always very high, all  
modes except off.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Check the feed “trim” button and adjust to higher  
(clockwise) setting. If the feed is too low, the stove  
will cool down and when it reaches a lower  
temperature will shut down automatically. This can  
be corrected by adjusting the feed setting to a  
higher setting.  
Trouble Shooting Flow Chart #11 - Stove runs fine and then  
shuts off for no apparent reason.  
Trouble Shooting Flow Chart #12 - Fan speed erratic  
(Surges)  
Feed System exploded view  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pre 2005 control switch assembly  
2005 and newer control switch assembly  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EasyFire B Model Pellet Heater Quick Troubleshoot and Technical Guide  
SPI’s EasyFire pellet heaters are designed to operate as a seasonal zone heater burning 1/4" wood pellet fuel. Utilizing a  
12VDC control and drive system allows for extended battery operation when AC power fails. The following outlines the  
general operating parameters and trouble shooting encountered during installation and seasonal operation. Basic  
operation is controlled combustion of wood pellets metered by the feed drive system into a burn pot and a  
combustion/convection fan motor providing separate air for combustion and heat exchange. This process is controlled by a  
digital main controller which monitors all function through two sensors and incoming outgoing operating voltages.  
Additionally, starting functions are provided by an industrial style cartridge heater located in the burn pot and both internal  
and optional thermostat.  
Standard operation: With both 120VAC and 12VDC battery power attached and a functional pellet flue system the heater  
is designed to operate continuously during the heating season. On a daily bases the heater requires fuel to be added to the  
storage hopper and depending on the fuel quality, burn pot area cleaned. Starting and operating sequences are controlled  
by an operating software program contained on a EPROM memory chip. Fuel rate is controlled by mode setting and trim  
position (standard trim knob setting is 9:00 and is located on control panel next to operation buttons). Normal start up and  
operation summary follows:  
Condition - Heater is cold, power connected, button to “OFF” position. Hopper door closed (safety switch closed). External  
thermostat jumped (factory standard) or optional thermostat closed to call for heat.  
1)  
Select a run button (Low, Medium, High) and press. The LED light will shift from OFF to run button.  
Feed motor starts initial fuel shot (approx. 40 seconds) and ignitor ON. Ignitor will begin to start heating  
and pass 300 degrees in 30 seconds.  
A)  
B)  
Fan motor starts in 60 seconds @ 3 volts providing combustion and convection air. Feed will cycle OFF  
completing the start up fuel shot. Smoke will be visible normally visible through the door glass with in 2  
minutes.  
C)  
Feed will cycle ON for short periods during the start cycle add small amounts of fuel. Heater continue in  
START UP mode until temperature rise is confirmed by sensors or for a total of 10 minutes.  
If temperature does not increase by 15C during this STARTUP phase the heater will begin the SHUTDOWN (for  
further information read SHUTDOWN in several paragraphs).  
2)  
RUN mode begins when temperature rise is achieved (normally within 5-7 minutes).  
Fan increases based on run button selected. Feed pulses increase based on temperature and TRIM  
setting. Feed trim adjustment allows for a lower or higher average fuel delivery.  
A)  
Initial flame is high based on a cool heater and fuel shots provided for start up. As operating temperature is  
reached the feed pulse will decrease and flame will drop.  
B)  
Feed rate will vary up and down as the heater adjusts for operating temperature. Temperature measured  
at T-2 sensor mounted on fan housing manifold.  
Heater will continue to operate as long as fuel, thermostat setting, and operating button remains.  
C)  
Condition - Shutting down operating heater. Selecting the OFF button or external thermostat no longer calls for heat.  
A)  
B)  
Feed motor immediately stops. No fuel is added to the burn pot and the coals remaining began the burn  
out.  
Fan is reduced to shut off voltage of 5 volts and maintained until sensor T-2 records a 20C reduction of  
temperature or 20 minutes time elapses.  
Other related operating parameters  
Three basic functions are constantly monitored during operation including flue drafting, operating temperatures, and AC  
power input. Blocked flue will cause an unsafe condition and will cause the unit to shut down with a steady RED fault  
indication noted on the control panel. Continued high temperature may cause a unsafe condition. The heater will stop the  
feed during high temperatures to allow the heater to cool. A flashing RED will indicate high operating temperature. AC  
power outage will stop external thermostat function if the optional battery is connected allowing the heater to run  
continuously while AC is out.  
Common operating problems:  
(Refer to installation manual and repair manual for additional information regarding specific component replacement and  
testing).  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Basic tools required for troubleshooting - Multi Volt/Ohm Meter, standard and phillips screw drivers, standard jewelers  
screw driver (fan speed adjustments on main control board).  
No power - Power is provided by both AC and DC supplies. There are two replaceable fuses located near the power  
connections. They are identified as Main (1 amp) and Ignitor (5 amp). If AC power is present to the main control system a  
LED will be lit on the OFF button. If DC power is present a GREEN LED will be lit on the control panel.  
Quick Testing -  
1)  
2)  
3)  
Check AC power with volt meter at wall socket - 115VAC.  
Check DC power at battery - 12VDC.  
Remove fuses and check continuity with OHM meter. Blown fuses can be cause by voltage spikes (lightning,  
power company). If fuse is found blown, replace only once and retest. If the fuse blows again further  
troubleshooting is required before further fuse replacement.  
Start up:  
No fuel - Fuel located in the hopper is feed by a auger from the hopper bottom up to the shoot which directs the pellets into  
the burn pot. The feed motor is controlled by the main control system and on models EF3801B, 5001B, and 5001U-B a  
hopper safety switch (EF4001-B auger can not be accessed from the hopper door). The switch will disable the feed system  
if the hopper lid is open. The switch is located on the upper right hopper vertical panel and is accessed through a small  
panel. Fuels is only feed in Low to High operating modes and requires “priming” auger. If hopper is out of fuel, cycle from  
OFF to LOW several times to allow pellets to feed into burn pot.  
Quick Testing -  
1) Confirm hopper lid is sitting on the switch arm and the arm is closing. With hopper lid open, push the switch arm down  
and listen for click noting switch closure. With heater cold, and lid open, push switch arm down, push Low and the feed  
motor should start to turn.  
2) Confirm feed motor is not jammed by emptying hopper and verifying a foreign object has not be caught. Remove top  
cover from feed tube from inside hopper if there is any question. If the feed motor is mechanically jammed, the control  
system has a built in circuit breaker. The breaker will require a reset by cycling from OFF to LOW. Do not recycle more  
than three times so the circuit does not become damaged by overheating.  
3) Pellets Jammed in feed shoot (above burn pot). Remove all jammed pellets and clean shoot with scraper.  
Ignitor does not heat up - The ignitor has a separate 120VAC circuit which includes a fuse, relay, and ignitor. This circuit is  
activated by the main control board via a 12VDC wire harness lead. When the main control call for start the 12VDC circuit  
is closed sending 12VDC to the relay. As the relay closes, the 120VAC circuit is completed and the ignitor begins to heat.  
As noted in prior section, if 120VAC power is not available the heater will still start the fan and feed if 12VDC is connected  
allowing a manual start with starter and match light.  
Quick Testing -  
1)  
2)  
Inoperative ignitor most likely have a blown fuse. Remove the 5 amp ignitor fuse and test with OHM meter.  
Replace if blown. As noted before if fuse blows again then further testing is required.  
Testing ignitor requires access to the relay located near the main board assembly. Access is through the lower  
right pedestal for the 3801/5001, junction box on the 4001 insert, and lower right cabinet for the 5001U. Remove  
the power to the unit. Unplug the ignitor lead from the relay and the neutral circuit. Using the OHM meter check for  
continuity between the two leads. If the circuit is open the ignitor has failed. If the circuit is complete check one  
lead and then ground the other lead to the ignitor base. If circuit is complete ignitor has failed. A grounded circuit  
will cause the fuse to blow.  
3)  
If ignitor check out, remove the harness leads to the relay and using the volt meter set to 20VDC, confirm 12VDC  
when the power is reapplied a run button is pushed. If 12VDC is found then the relay has failed.  
Heater starts then burns out - The start up is controlled by the control system and best results are from a cold start. If a  
warm heater is immediately restarted it may not be able to confirm the required temperature increase as the heater  
temperature is already warm and the temperature is actually falling during the initial start up. Allow the heater to cool and  
shut down before restarting.  
Trim settings - Will not change the first portion of the start up however will effect the initial run mode. If the trim is fully  
counter clockwise (Lowest) the heater may run low on fuel, most likely if the operating conditions are warm. High or Max  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
trim settings may cause the opposite problem as the heater feeds to much fuel and allows the HIGH TEMP control stop  
the feed to cool the stove. Best starting trim setting is the mid point or 9:00 o-clock.  
High temp starts will also occur if the burn pot has additional fuel prior to start up. This additional fuel which is then added  
too as the start cycle begins pushes the temperatures up as the heater starts. This is considered an temperature  
overshoot as the temperature climbs quickly.  
Heater will not start when run button is pushed - Check external thermostat jumper or remote thermostat as the unit will  
not attempt a start unless this circuit is closed.  
Run mode Troubleshooting:  
Once the heater reaches the run mode it will continue operation by using the coals in the burn pot to light the pellets  
continuing to fall. If the coal bed burns down at some point the pellets may not light and then the heater will shut down.  
This is normally confirmed by finding the burn pot with unburned fuel and shut off. This can also happen if the hopper runs  
low on fuel or the fuel bridges (hangs on the hopper sides).  
Run mode problem generally are either operational or limits exceeded - Blocked Flue (loss of flue draft) or High  
Temperature is exceeded. Blocked flue indication is a solid RED LED on the control panel and requires a recycle of the  
heater to clear. This is for the operators protection as a blocked flue could cause a dangerous condition. Block flue most  
likely is not fully blocked and will occur if the flue pipe is subject to high wind conditions or is blocked by ash. If this  
happens during initial installation a corrective action to the flue system will be required. Check the installation manual for  
flue recommendations.  
Operational problems are generally related to ash build up in the burn pot or the heat exchange system and can be correct  
by cleaning.  
Over Feeding - Over feeding is a common problem and is related to a lack of combustion air rather than to much fuel. If  
the heater is clean and seems to feed more fuel adjust the trim down to slow the feed rate. If the heater has been operated  
for sometime since the last cleaning then shutting it down and cleaning will solve the over feed. Check the door for proper  
adjustment as a partially closed door will cause reduced combustion air. Operating the heater for an extended time with an  
open door will cause a shut down with RED LED and require a restart.  
Immediate RED LED when a run mode is selected indicates a failed sensor (generally a T-1). Replacement of sensors are  
accomplished by removing the rear access panel and normally requires removing the flue pipe. Review repair manual for  
additional information.  
Shutdown:  
Shut down is the simplest mode as the feed is stopped and the fan continues to operate until the heater is cool. If the fan  
continues to run after it is fully cold then the T-2 sensor and the main control did not register the required temperature  
reduction. Unplug the heater to reset and run again. If problem persists then the T-2 sensor or the control system will  
require component replacement.  
Battery Operation Troubleshooting -  
Battery operation requires a fully charge 12VDC battery capable of sustained 2 amp/hr. loads while maintaining a minimum  
of 11.2 VDC. This voltage is required for proper system operation. Most battery operation problems can be traced to a  
battery in pour condition.  
Quick Testing  
Remove battery from heater and charge overnight with automotive type battery charger. Test battery with automotive load  
tester. Replace if required. Testing connections from terminals on rear of heater back to the harness. If all connects are  
secure a main control board will be required.  
Additional detailed information is contained in the installation and repair manuals. Please refer to these for in depth  
troubleshooting guides and harness replacement.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Component Adjustments and Replacement:  
Main Control Board - Main control board is located in the lower right pedestal (3801/5001) or lower right rear - 4001 insert  
and right switch plate for the 5001U. The control board is held in place with several phillips screws.  
Fan speed adjustments are accomplished by turning the LOW and HIGH fan pots on the lower right corner. These  
adjustments are made in the corresponding run mode. Factory settings are based on fan voltage as read across the motor  
terminals 6.8VDC LOW , and 9.0VDC HIGH.  
A GREEN LED light flashes on the control board to confirm AC or DC power is present.  
Switch Board - Switch board is attached to access panel with several phillips screws. Harness plugs into bottom of switch.  
Sensors - Access for sensors is through the rear panels. Both the T-1 and T-2 sensors are the same sensor type mounted  
differently. T-1 is mounted on the exhaust side of the combustion fan housing. It is held in place with a tie wrap. T-1 sensor  
allows for cabinet air to drawn through the high temp plastic holder. When door is open or flue blocks the flow reverses. T-  
2 sensor is attach to a aluminum block and attached to the manifold. Wire harness connections should be secure and not  
pulled tight.  
Additional information is available on line@ www.sierraproductsinc.net/pages/customer_service  
Technical Customer Service - 909-399-3355x29  
Red Light Fault Indications:  
When the Hi-Temp/Flue indicator light comes on (red lite beneath control knob) it means a fault has been detected in  
either the flue system, over temperature, or fan/feed motor.  
Slow Flash Red Light - Indicates a blocked flue. Check flue and clean out for built up ash deposits.  
Solid Red Light - Indicates an over temperature. Check the air intake at rear of unit. Turn the feed trim down 25% to  
reduce fuel rate.  
Fast Flash Red Light - Requires unit to be unplugged to reset. Indicates a feed motor jam or fan motor fault. Fan motor  
test would require running unit on “fan and clean” only to determine if red light indication is repeated. If not, feed system is  
jammed and requires the hopper access cover to be removed and jammed material to be removed  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EF AutoLite Igniter  
Replacement Instruction  
Please read this entire instruction before attempting repair.  
WARNING - ELECTRIC SHOCK POTENTIAL.  
Basic start up operation is as follows (with thermostat  
jumped):  
All repairs must be accomplished with the  
115VAC and 12 DC power disconnected from  
heater.  
1) From “Off” press operating button (Low). DC controller  
energizes the 115VAC relay completing the igniter high  
voltage connection. Igniter temperature immediately  
rises from room temperature.  
2) Combustion fan starts at 1 minute along with feed motor  
for 1 ½ minutes providing start up fuel.  
3) Pellets start to ignite approx. 3 to 4 minutes. Feed motor  
starts at 4 minutes to provide additional start up fuel.  
4) At 7 minutes unit should have flame in burn pot. If no  
temperature rise is noted by T-1 (sensor) at 20 minutes  
heater starts shut down process.  
TROUBLESHOOTING IGNITER SYSTEM  
The igniter system incorporates a cartridge style high  
wattage 115VAC igniter located at the bottom of the pellet  
burn pot. This system is continuously cooled by incoming  
combustion air and provides years of general service.  
However, for the igniter to work properly the burner pot must  
be cleaned as required to allow the pellets to fall onto the  
igniter. Generally, this is accomplished during normal  
cleaning which would include removing the burn pot and  
brushing the ash from the pot and igniter. Removing the  
screen from below the ignitor and brushing all ash from the  
burn pot holder will also aid in the starting process.  
Figure 1 Insert Connection Panel  
Check the igniter rod surface for disintegration or obvious  
damage. If any white ceramic material is showing through  
the SS protective cover the igniter should be replaced.  
Once the burn pot is cleaned and the igniter inspected the  
remaining system checks are electrical. A simple check of  
the system may be accomplished on a cold heater by  
placing a gloved hand on the igniter rod and pressing one of  
the operating button (Low). The igniter will start to get hot  
immediately (2 minute temperature 500°F). If not  
temperature rise is noted then continue with electrical  
trouble shooting.  
Figure 2 Stove Connection Panel  
GENERAL INFORMATION  
Your EASYFIRE Pellet Heater is equipped with the Autolite  
Automatic ignition and operating system.  
The AutoLite system is integrated into the heater to allow for  
automatic start up using a heating element located in the  
burn pot. This element starts the initial fire required to burn  
the wood pellets. The system operates on 115VAC power  
supplied through a separate fuse for seven minutes during  
the initial heater start up. After the seven minute period the  
AutoLite system is deactivated and the heater operates  
based on the EasyFire digital control system requirements.  
If the house AC power should quit, the AutoLite system will  
not be available. however, with the optional battery attached  
the heater can be manually lit.  
Autolite Wiring Diagram  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL TROUBLE SHOOTING  
WARNING: Only a trained technician should attempt to  
repair a pellet heater electrical system.  
Note: All tests should be accomplished with the unit  
thermostat by-passed.  
Remove both AC and DC power from unit. The igniter  
system is protected with a 5 amp fuse located on the back  
or side of the heater (Figure 1). The igniter is switched “Off”  
and “On” by the control system via a relay located in the  
lower right pedestal in front of the control board  
(EF3801/5001) or in lower left rear of the unit accessed  
from the back (EF4001). Wiring on all igniter systems are  
the same. The following test steps will require a multi-meter  
with AC/DC volt and ohm functions:  
a. Unplug heater from wall outlet and 12VDC power!  
b. Remove 5 amp fuse holder cap and fuse by pressing  
in and turning counter clockwise. Test fuse with ohm  
meter to confirm is not “open”. If fuse is open go to  
Testing Igniter “d”. If fuse is good continue.  
REPLACEMENT PARTS:  
c. Check 115VAC power wire connection to relay and  
neutral wire connection to igniter terminal. This can  
be accomplished with the ohm meter. If wire is  
disconnected or open replace.  
ITEM  
NO.  
PART  
NO.  
DESCRIPTION  
1
2
120120  
120117  
120118  
202163  
202164  
300501  
300500  
110510  
12VDC RELAY  
d. Disconnect igniter leads from relay and neutral. Test  
continuity with ohm meter between leads. If open  
igniter is defective. If continuity exists then check for  
internal grounding by checking each lead to the  
shielded conduit of the igniter leads. If continuity  
exists to ground then igniter is defective. If meter  
reads open on both leads to ground then igniter  
should produce heat when properly connected to  
115VAC.  
CARTRIDGE HEATER  
3
AUTOLITE CONTROL SWITCH  
BURN POT SCREEN 5001  
4a  
4b  
5a  
5b  
6
BURN POT SCREEN 3801/4001  
BURN POT 5001-AUTOLITE  
BURN POT 3801/4001-AUTOLITE  
5 AMP FUSE MDL5 (NOT SHOW N)  
e. With igniter disconnected from relay, attach volt  
meter (set meter to 200VAC) leads to relay 115VAC  
out terminal and igniter neutral. Reapply 115VAC  
power. Press operating button low. Relay should  
immediately engage applying 115VAC to meter. If  
meter has 115VAC then replace igniter as it should  
be activated. If no AC power outputted from relay.  
Continue to next test.  
Customer Service & Replacement Parts  
Replacement parts are available from your local dealer or  
f. Disconnect DC control wires from harness to relay.  
Attach volt meter (set meter to 20VDC) leads to  
harness terminals. Reapply 115VAC power. Press  
operating button low. Control system should  
immediately engage applying 12VDC to meter. If  
meter has 12VDC then replace relay as it should be  
activated. If relay does not engage, exchange control  
board and/or main switch board.  
Customer Service  
Sierra Products, Inc.  
5061 Brooks St. Ste. B,  
Montclair, CA 91763  
Phone 1-909-399-3355  
Fax 1-909-399-3357  
Sierra Products, Inc. 5061 Brooks St. Ste. B, Montclair, CA 91763  
22  
P/N 140804 10/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sierra Products, Inc. 5061 Brooks St. Ste. B, Montclair, CA 91763  
23  
P/N 140804 10/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pre 2004 Pellet Stove Wiring Detail  
Sierra Products, Inc. 5061 Brooks St. Ste. B, Montclair, CA 91763  
24  
P/N 140804 10/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2005 HARNESS WIRING DETAIL  
Sierra Products, Inc. 5061 Brooks St. Ste. B, Montclair, CA 91763  
25  
P/N 140804 10/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EF3801/4001 V1 Feed System  
Service or Repair Instruction  
OVERVIEW  
The EasyFire feed system consists of four main components, feed  
motor and mounting plate, feed auger shaft, feed disk, and feed disk  
bushing (Figure 1). These components are designed to provide  
thousands of hours of service and rarely require service or  
replacement. Operation of feed system is controlled by the main  
control board based on the stoves temperature and heat setting. Unlike  
other pellet stoves, the system operates by increasing and decreasing  
the speed of the auger and disk. Pellets are pushed forward toward the  
disk and as the disk rotates clockwise (from front of stove) allows the  
pellets to be feed into the shoot. Three feed disk sizes are available  
with the standard = 1, medium = 2, and large = 3. #3 feed disks are for  
large or long pellets only. If overfeeding or under-feeding is a problem  
and adjusting the feed trim will not compensate, changing the feed disk  
is advised.  
Figure 1  
Removing and Replacing the Feed Assembly: The feed assembly  
and gear motor is accessed by removing the rear inspection panel for  
both the heater and insert. Remove the four or six #8 screws  
attaching the inspection cover and remove cover. Remove all pellets  
from hopper and feed disk area inside unit. Locate feed motor and  
unplug wire harness connections (note location of red banded wire on  
motor to assure proper rotation of motor). Remove wing nuts (or #10  
nuts on some units) attaching feed motor bracket to rear of feed shoot.  
Gently remove feed assembly by pulling toward the rear of unit. The  
feed shaft maybe removed by loosening the allen screws holding the  
shaft coupler. Remove the two #8 phillips screws holding the feed  
motor bracket to the gear motor. Reverse process to install feed  
motor assembly.  
Bushing replacement: Disk bushing may be replaced by removing 2-  
#8 retaining screws and carefully prying with a large flat blade screw  
driver from inside hopper (Figure 2). To re-install bushing clean area  
with thinner or alcohol and apply a small amount of red lock-tight to bushing. Align with plate and carefully pry back with  
screw driver. Straighten bushing and install retaining screws.  
Shaft or Disk Replacement: The feed disk and shaft depth are set  
at the factory to allow the feed disk to ride fully in the feed disk  
bushing. When replacing either component, make sure the installed  
disk ride toward the rear of the disk (Figure 3) and does not extend  
to far forward. If the disk is set to far forward it may jamb causing  
the shaft to bend or break. Assemble the new components onto the  
motor drive loosely then install into stove. Carefully position disk and  
mark or tighten disk onto shaft. Remove disk and motor assembly  
from stove and tighten with 1/8" allen wrench.  
NOTE: WHEN ASSEMBLING THE SHAFT AND COUPLER,  
ALWAYS USE A SMALL AMOUNT OF LOCK TIGHT (RED) ON  
ALLEN SET SCREWS. AFTER THE ASSEMBLY HAS BEEN  
INSTALLED THE FEED DISK MUST RIDE IN THE CENTER OF  
THE FEED BUSHING.  
Figure 3  
5061 Brooks St. Montclair, CA 91763  
800-527-4790 Fax 1-909-399-3357  
P/N EF3801 4001 Sensor replacment 4/04  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EF3801/4001 T-1/T-2 Sensor  
Replacement Instruction  
OVERVIEW  
First production 2005 stoves Serial #3384 to #3420 require precautionary replacement of both T-1 and T-2 sensors. The  
sensors located in the stove body sense the operating temperatures and overall parameters of the stove. The T-1 sensor  
provides blocked flue and operating sensing while the T-2 sensor provides start up, shut down, and over temp. sensing.  
The first 26 units have a sensor assembly attached in such a way that may cause the stove to act erratically. As a  
precaution we are requiring replacement of the sensors and offering a repair credit. Please contact customer service @  
800-527-4790x29 for further information.  
T-1 and T-2 Sensor Replacement:  
Removal from 3801 and 4001 Insert: The T-1 and T-2 sensors maybe accessed by removing the inspection covers on  
back of the unit. The T-1 sensor is installed into to the right side of the combustion housing just above the exhaust tube.  
Unplug the harness connector to the sensor. Using a wrench, unscrew the brass fitting and sensor holder from the  
exhaust pipe. The T-2 sensor is located right of the combustion housing attached on the lower portion of the manifold.  
Unplug the harness connector the sensor. Remove the #10 nut attaching the sensor holder and remove the sensor.  
Reverse process to install new sensor fitting and holder. Reinstall the rear panel and confirm standard operation.  
5061 Brooks St. Montclair, CA 91763  
909-399-3355 Fax 1-909-399-3357  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REMOVAL AND REPLACEMENT OF COMPONENTS  
WARNING: RISK OF ELECTRIC SHOCK! REMOVE ALL POWER CORDS FROM UNIT BEFORE ATTEMPTING ANY  
SERVICE.  
1.  
Circuit Board: The circuit board is located on the lower right hand side of the heater or insert (facing  
from the front fig.1 - pg. 21).  
Removal from Heater: Remove the two #8 phillips screws securing the panel to the pedestal side. Open the panel  
by lifting up and out. Lay panel flat and remove two #8 phillips screws securing the control board stand-offs to the panel.  
Gently remove board from 44 pin connector by firmly holding panel and pulling board toward you. Remove #8 nuts  
attaching stands to the board and remove stands (these nuts are located on the lower right and left corners of the board).  
Reverse the process to install new control board.  
Removal from Insert: Remove the two #8 phillips screws securing the control cover from the hopper side.  
Remove the two #8 phillips screws attaching the control board the stand-offs (these screws are located at the lower right  
and left corners of the board). Gently remove board from 44 pin connector by pulling down on the board. Reverse the  
process to install a new control board.  
2. Fan Motor: The fan motor is located directly under the combustion fan housing. Access is provided through  
the rear inspection covers on both the heater and insert. Remove the #8 screws attaching the covers. Remove the wire  
harness leads to the motor noting there position both red and black. Next remove the plastic convection fan blade by  
carefully pushing against the fan hub. Remove the four #10 nuts holding the fan motor base plate to the housing. Carefully  
pry the base plate breaking the factory silicon seal. Remove motor from unit. Using a long allen wrench loosen the allen  
set screws holding the combustion fan blades on the motor shaft. Remove the two #10 nuts holding the motor mount tho  
the fan plate. Remove the two #8 phillips screws holding the motor mount to the motor. Reverse the process to replace fan  
motor assembly.  
NOTE: WHEN INSTALLING THE COMBUSTION FAN BLADES ON THE MOTOR SHAFT, USE LOCK TIGHT (RED)  
ON THE ALLEN SET SCREWS. THE PROPER POSITION OF THE BLADES IS THE OUTER BLADE POSITIONED AT  
THE END OF THE SHAFT AND THE SECOND BLADE TIGHT TO THE BACK OF THE FIRST. WHEN ASSEMBLING  
THE FAN MOTOR PLATE BACK INTO THE UNIT, USE HIGH TEMPERATURE SILICONE SEAL ON CLEANED  
MATING SURFACES.  
Fan motor brushes maybe replaced by carefully removing the plastic screw caps on each side of the motor and replacing  
with factory replacements.  
3. Control Switch: The control switch is located on the right side of both the heater and insert. In both units  
remove the two #8 phillips screws holding the cover. Using a small blade standard screw driver carefully loosen the set  
screw on the control knob. Next remove the 9/16 nut attached to the switch shaft. Remove the switch and unplug the  
harness connector. Reverse procedure to install new  
switch.  
4. Transformer and Rectifier: The transformer and rectifier are located inside the cabinet on both the heater and  
insert. Remove the inspection cover on the rear and locate the transformer. Remove the two #6 phillips screws and nuts.  
Remove the wires noting the positions. Remove the transformer. The rectifier maybe removed by unplugging the wires  
from the harness and transformer (note the position of the red and black harness wires). Remove the #6 phillips screw  
and nut. Remove the rectifier. Reverse the procedure to install new parts.  
5061 Brooks St. Montclair, CA 91763  
909-399-3355 Fax 1-909-399-3357  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5061 Brooks St. Montclair, CA 91763  
909-399-3355 Fax 1-909-399-3357  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5061 Brooks St. Montclair, CA 91763  
909-399-3355 Fax 1-909-399-3357  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sennheiser Video Game Headset SD Office HS User Manual
Shindaiwa Trimmer DH254 User Manual
Silvercrest Oven SGB 1380 A1 User Manual
Snapper Tiller 1691277 User Manual
Sony Cassette Player XR 7850 User Manual
Sony CD Player RM X83RF User Manual
Sony Personal Computer VGC LV200 User Manual
Sony Speaker SA W303 User Manual
Speco Technologies Speaker SP 4NXC T User Manual
Tannoy Cell Phone W395 User Manual