Sharp Air Cleaner FP P40CX User Manual

R
FP-P40CX  
AIR PURIFIER  
OPERATION MANUAL  
PURIFICATEUR D’AIR  
MANUEL D’UTILISATION  
This product earned the ENERGY STAR by meeting  
strict energy efficiency guidelines set by the US EPA.  
US EPA does not endorse any manufacturer claims  
of healthier indoor air from the use of this product.  
The energy efficiency of this ENERGY STAR quali-  
fied model is measured based on a ratio between the  
model’s CADR for Dust and the electrical energy it  
consumes, or CADR/Watt.  
Ce produit a le droit de porter la marque ENERGY  
STAR après avoir répondu à des critères stricts en ce  
qui concerne l’efficacité énergétique, tels qu’établis  
par l’agence EPA aux É-U. L’agence EPA aux É-U  
n’appuie aucunement les témoignages publicitaires  
du fabricant indiquant que ce produit rend l’air intérieur  
des locaux plus sain.  
Free Standing type  
Type mobile  
L’efficacité énergétique de ce modèle, qui bénéficie  
de la reconnaissance ENERGY STAR, est mesurée  
par le rapport entre le DAP (débit d’air purifié) du  
modèle et l’énergie électrique qu’il consomme, soit le  
rapport DAP/Watt.  
*Plasmacluster is a trademark of Sharp Corporation.  
*Plasmacluster est une marque de commerce de Sharp Corporation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENGLISH  
CONTENTS  
FEATURES  
• FOR CUSTOMER ASSISTANCE(U.S).... E-2  
Plasmacluster Ion Control  
Your new air purifier will control the ratio  
of negative ions and positive ions depend-  
ing on the condition of the room.  
• CONSUMER LIMITED WARRANTY(U.S)E-3  
FOR CUSTOMER ASSISTANCE(CANADA)...E-4  
LIMITED WARRANTY(CANADA) ........ E-5  
• Clean Mode  
Approximately the same numbers of posi-  
tive and negative ions are discharged.  
IMPORTANT SAFETY INSTRUCTIONS .... E-6  
• WARNING ....................................................E-6  
• CAUTIONS CONCERNING OPERATION ...E-7  
• REMOTE CONTROL LIMITATIONS ............E-7  
• INSTALLATION GUIDELINES .....................E-7  
• FILTER GUIDELINES ..................................E-7  
• Ion Control Mode  
Plenty of negative ions exist in natural  
surroundings such as waterfalls or forests.  
In this mode, negative ions will be re-  
leased at an increased rate.  
• AUTO Plasmacluster Ion Mode  
The unit will switch between Clean Mode  
and Ion Control Mode automatically de-  
pending on the amount of impurities in the  
air detected by the odor sensor.  
PART NAMES.......................................... E-8  
• MAIN UNIT DISPLAY ...................................E-8  
• INCLUDED...................................................E-8  
• BACK ...........................................................E-8  
• Filters  
1) Washable Active Carbon Filter  
Absorbs odor elements.  
PREPARATION........................................ E-9  
• INSERTING BATTERIES  
IN THE REMOTE CONTROL ......................E-9  
Washable to maintain optimum  
deodorization performance.  
• REMOTE CONTROL USE ...........................E-9  
• FILTER INSTALLATION ............................ E-10  
2) True HEPA (High Efficiency  
Particulate Air) Filter.  
OPERATION .......................................... E-12  
• MAIN UNIT OPERATION .......................... E-12  
• REMOTE CONTROL OPERATION .......... E-14  
High-efficiency particle collection in-  
cluding pollen and dust.  
CARE AND MAINTENANCE................. E-15  
• MAIN UNIT................................................ E-15  
• ODOR SENSOR ....................................... E-15  
• FILTER CLEANING................................... E-15  
Declaration of Conformity  
SHARP AIR PURIFIER FP-P40CX  
This device complies with Part 18 of FCC  
rules.  
WASHABLE ACTIVE CARBON FILTER CARE .... E-16  
• FILTER REPLACEMENT  
GUIDELINES ............................................ E-17  
Responsible Party:  
SHARP ELECTRONICS CORPORATION  
Sharp Plaza,  
TROUBLE SHOOTING.......................... E-18  
Mahwah, New Jersey 07430-2135  
TEL: 1-800-BE-SHARP  
SPECIFICATIONS ................................. E-19  
Declaration of Conformity  
SHARP AIR PURIFIER FP-P40CX  
This ISM device complies with Canadian  
ICES-001  
Thank you for purchasing the SHARP Air Puri-  
fier. Please read this manual carefully for the cor-  
rect usage information. Before using this prod-  
uct, be sure to read the section: “Important Safety  
Instructions.”  
Responsible Party:  
SHARP ELECTRONICS OF CANADA LTD.  
335 Britannia Road East Mississauga,  
Ontario L4Z 1W9 Canada  
After reading this manual, retain it in a conven-  
ient location for future reference.  
TEL: (905) 568-7140  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E-1  
FOR CUSTOMER ASSISTANCE (the United States)  
To aid in answering questions if you call for service or for reporting loss or theft, please use  
the space below to record the model and serial number located on the back side of the unit.  
MODEL NUMBER  
SERIAL NUMBER  
DATE OF PURCHASE  
Dealer Name  
Address  
City  
State  
Zip  
Telephone  
TO PHONE: Dial 1-800-BE-SHARP (237-4277) for:  
SERVICE (for your nearest Sharp Authorized Servicer)  
PARTS (for your Authorized Parts Distributor)  
ACCESSORIES  
ADDITIONAL CUSTOMER INFORMATION  
TO WRITE: For service problems, warranty information, missing items and other assistance:  
Sharp Electronics Corporation  
Customer Assistance Center  
1300 Naperville Drive  
Romeoville, IL 60446-1091  
Please provide the following information when you write or call: model number, serial  
number, date of purchase, your complete mailing address (including zip code), your daytime  
telephone number (including area code) and description of the problem.  
Download from Www.SomanualsE.co-m2. All Manuals Search And Download.  
CONSUMER LIMITED WARRANTY  
CONSUMER LIMITED WARRANTY FOR U.S. USERS  
SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the  
“Product”), when shipped in its original container, will be free from defective workmanship and materials, and agrees that  
it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured  
equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below.  
This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s) set forth below  
nor to any Product the exterior of which has been damaged or defaced, which has been subjected to improper voltage or  
other misuse, abnormal service or handling, or which has been altered or modified in design or construction.  
In order to enforce the rights under this limited warranty, the purchaser should follow the steps set forth below and provide  
proof of purchase to the servicer.  
The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers by law.  
ALL IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE  
LIMITED TO THE PERIOD(S) FROM THE DATE OF PURCHASE SET FORTH BELOW. Some states do not allow  
limitations on how long an implied warranty lasts, so the above limitation may not apply to you.  
Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those  
described herein, or to extend the duration of any warranties beyond the time period described herein on behalf of Sharp.  
The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shall be the sole and  
exclusive remedy available to the purchaser. Correction of defects, in the manner and for the period of time described  
herein, shall constitute complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the  
Product, and shall constitute full satisfaction of all claims, whether based on contract, negligence, strict liability or  
otherwise. In no event shall Sharp be liable, or in any way responsible, for any damages or defects in the Product which  
were caused by repairs or attempted repairs performed by anyone other than an authorized servicer. Nor shall Sharp be  
liable or in any way responsible for any incidental or consequential economic or property damage. Some states do not  
allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you.  
THIS WARRANTY GIVES YOU SPECIFlC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY  
FROM STATE TO STATE.  
FP-P40CX Air Purifier. Be sure to have this information available when  
you need service for your Product.  
Your Product Model Number & Description:  
Warranty Period for this Product:  
One (1) year parts and labor from date of purchase.  
Appearance items of the Product, filters, accessories, or any printed  
materials. Product which has been used for rental and/or commercial  
purposes.  
Additional Item(s) Excluded From Warranty  
Coverage:  
Where to Obtain Service:  
From a Sharp Authorized Servicer located in the United States. To find  
the location of the nearest Sharp Authorized Servicer, call Sharp Toll Free  
at 1-800-BE-SHARP.  
What to Do to Obtain Service:  
Ship prepaid or carry in your Product to a Sharp Authorized Servicer. Be  
sure to have Proof of Purchase available. If you ship the Product, be sure  
it is insured and packaged securely.  
TO OBTAIN SUPPLY, ACCESSORY OR PRODUCT INFORMATION, CALL 1-800-BE-SHARP, OR VISIT OUR WEBSITE AT  
R
SHARP ELECTRONICS CORPORATION  
Sharp Plaza, Mahwah, New Jersey 07430-2135  
Download from Www.SomanualsE.co-m3. All Manuals Search And Download.  
FOR CUSTOMER ASSISTANCE (Canada)  
To aid in answering questions if you call for service or for reporting loss or theft, please use  
the space below to record the model and serial number located on the back side of the unit.  
MODEL NUMBER  
SERIAL NUMBER  
DATE OF PURCHASE  
Dealer Name  
Address  
City  
Province  
Postal Code  
Telephone  
TO PHONE: Dial 1-905-568-7140 for:  
SERVICE (for your nearest Sharp Authorized Servicer)  
PARTS (for your Authorized Parts Distributor)  
ACCESSORIES  
ADDITIONAL CUSTOMER INFORMATION  
TO WRITE: For service problems, warranty information, missing items and other assistance:  
Sharp Electronics of Canada Ltd.  
Customer Care  
335 Britannia Road East  
Mississauga, Ontario L4Z 1W9  
Please provide the following information when you write or call: model number, serial number,  
date of purchase, your complete mailing address (including Postal Code), your daytime  
telephone number (including area code) and description of the problem.  
E-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
LIMITED WARRANTY (VALID IN CANADA ONLY)  
Consumer Electronics Products  
Congratulations on your purchase!  
Sharp Electronics of Canada Ltd. (hereinafter called “Sharp”) gives the following express warranty to the first consumer  
purchaser for this Sharp brand product, when shipped in its original container and sold or distributed in Canada by  
Sharp or by an Authorized Sharp Dealer:  
Sharp warrants that this product is free, under normal use and maintenance, from any defects in material and  
workmanship. If any such defects should be found in this product within the applicable warranty period, Sharp shall, at  
its option, repair or replace the product as specified herein.  
This warranty shall not apply to:  
(a) Any defects caused or repairs required as a result of abusive operation, negligence, accident, improper  
installation or inappropriate use as outlined in the owner’s manual.  
(b) Any Sharp product tampered with modified, adjusted or repaired by any party other than Sharp, Sharp’s  
Authorized Service Centres or Sharp’s Authorized Servicing Dealers.  
(c) Damage caused or repairs required as a result of the use with items not specified or approved by Sharp, including  
but not limited to head cleaning tapes and chemical cleaning agents.  
(d) Any replacement of accessories, glassware, consumable or peripheral items required through normal use of the  
product including but not limited to earphones, remote controls, AC adapters, batteries, temperature probe, stylus,  
trays, filters, belts, ribbons, cables and paper.  
(e) Any cosmetic damage to the surface or exterior that has been defaced or caused by normal wear and tear.  
(f) Any damage caused by external or environmental conditions, including but not limited to transmission line/power  
line voltage or liquid spillage.  
(g) Any product received without appropriate model, serial number and CSA and/or cUL markings.  
(h) Any products used for rental or commercial purposes.  
(i) Any installation, setup and/or programming charges.  
Should this Sharp product fail to operate during the warranty period, warranty service may be obtained upon delivery  
of the Sharp product together with proof of purchase and a copy of this LIMITED WARRANTY statement to an  
Authorized Sharp Service Centre or an Authorized Sharp Servicing Dealer. In home warranty service may be provided  
at Sharp’s discretion on any Sharp television with the screen size of 27” or larger and on any Sharp Over-the-Range  
Microwave Oven.  
This warranty constitutes the entire express warranty granted by Sharp and no other dealer, service centre or their  
agent or employee is authorized to extend, enlarge or transfer this warranty on behalf of Sharp. To the extent the law  
permits, Sharp disclaims any and all liability for direct or indirect damages or losses or for any incidental, special or  
consequential damages or loss of profits resulting from a defect in material or workmanship relating to the product,  
including damages for the loss of time or use of this Sharp product or the loss of information. The purchaser will be  
responsible for any removal, reinstallation, transportation and insurance costs incurred. Correction of defects, in the  
manner and period of time described herein, constitute complete fulfillment of all obligations and responsibilities of  
Sharp to the purchaser with respect to the product and shall constitute full satisfaction of all claims, whether based on  
contract, negligence, strict liability or otherwise.  
WARRANTY PERIODS:  
Parts & Labour (exceptions noted)  
1 year  
1 year  
1 year  
Audio Products  
Camcorder  
DVD Products  
LCD Projector  
LCD TV  
1 year (lamp 90 days)  
1 year  
Microwave Oven  
Television Products  
VCR Products  
Vacuum Cleaner  
Air Purifier & Air Conditioners  
1 years (magnetron component-4 additional years)  
1 year (picture tube component-1 additional year)  
1 year  
1 year  
1 year (except filters)  
To obtain the name and address of the nearest Authorized Sharp Service Centre or Dealer, please contact:  
SHARP ELECTRONICS OF CANADA LTD. 335 Britannia Road, East Mississauga, Ontario L4Z 1W9  
H
T
O
For more information on this Warranty, Sharp Canada Products,  
Accessory Sales, Dealer or Service Locations, please call  
(905)568-7140  
Visit our Web site: www.sharp.ca  
SERVICE  
M
E-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
When using electrical appliances, basic safety precautions should be followed, including the  
following:  
WARNING - To reduce the risk of electrical shock, fire or injury to persons:  
• Read all instructions before using the air purifier.  
• Use only a 120-volt outlet with a polarized receptacle.  
• The air purifier has a polarized plug (one blade is wider than the other is). This plug will fit in a  
polarized outlet only one way. Initially, if the plug does not fit into the outlet, reverse it. If it still does not  
fit, contact a qualified electrician or service person.  
• Do not use the air purifier if the power cord or plug is damaged or the connection to the wall  
outlet is loose.  
Periodically remove dust from the power plug.  
• Do not insert fingers or foreign objects into the intake or air outlet.  
• When removing the power plug, always hold the plug and never pull the cord.  
Electrical shock and/or fire from short circuit may occur as result.  
• Do not use this air purifier near gas appliances or fireplaces.  
• Remove the power plug from the wall outlet before cleaning the unit and when not using the  
unit.  
Electrical shock from bad insulation and / or fire from short circuit may occur as a result.  
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent,  
Sharp authorized service or similarly qualified person in order to avoid a hazard.  
Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,  
sparks from lit cigarettes, chemical fumes in the air or in very high humidity condition, such as a  
bathroom.  
Use care when cleaning the air purifier. Strong corrosive cleansers may damage the exterior.  
Only Sharp Authorized Servicers should service this air purifier. Contact the nearest Servicer for any  
problems, adjustments, or repairs.  
The batteries must be removed from the remote control before disposal, and the batteries must be  
disposed of safely.  
NOTE - Radio or TV Intreference  
If this air purifier should does cause interference to radio or television reception, try to correct the  
interference by one or more of the following measures:  
• Reorient or relocate the receiving antenna.  
• Increase the separation between the air purifier and radio/TV receiver.  
• Connect the equipment into an outlet on a circuit different from that to which the receiver is con-  
nected.  
• Consult the dealer or an experienced radio/TV technician for help.  
Download from Www.Somanuals.Eco-m6. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
CAUTIONS CONCERNING OPERATION  
• Do not block the intake and air outlet.  
• Do not use the unit near or on hot objects, such as range or where it may come into contact with  
steam.  
• Do not use the unit on its side.  
• Always hold the handle on the back of the unit when moving it.  
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in  
bodily injury.  
• Do not operate the unit without the filter.  
• Do not wash and reuse HEPA filter .  
Not only it does not improve filter performance, it may cause electric shock or malfunction.  
• Clean the exterior with a soft cloth only.  
The unit surface may be damaged or cracked.  
In addition, the sensor may malfunction as a result.  
REMOTE CONTROL LIMITATIONS  
DO NOT USE THE REMOTE CONTROL IN THE FOLLOWING LOCATIONS:  
• Any location where there is inverter lighting equipment or electronic spontaneous lighting  
equipment  
The remote control may become inoperative. In this case, move away from such lighting equipment  
or change direction.  
• Location exposed to direct sunlight  
The unit may not receive signals from the remote control.  
INSTALLATION GUIDELINES  
• During the operation of the product, please place the unit at least 7 feet (2m) away from  
equipment which involve electric wave such as televisions, radios or wave clocks, in case  
electrical interference occurs to such equipments.  
• Avoid a location where the sensor is exposed to direct wind.  
The unit may not operate properly.  
• Avoid locations where curtains, etc., come into contact with the intake or air outlet.  
Curtains, etc., may become dirty or a malfunction may occur.  
• Avoid locations where the unit is exposed to condensation, due to drastic temperature changes.  
• Place on a stable surface with sufficient air circulation.  
• Do not install when there is generation of lampblack, such as in a kitchen, etc.  
The unit surface may crack or the sensor may malfunction as a result.  
• Leave at least 2 feet (60cm) of space from the wall.  
The wall behind the air outlet may become dirty as time passes. When using the unit for extensive  
period in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In addi-  
tion, periodically clean the wall, etc.  
FILTER GUIDELINES  
• Follow the instructions in this manual for correct care and maintenance of the filters.  
Download from Www.Somanuals.Eco-m7. All Manuals Search And Download.  
PART NAMES  
MAIN UNIT DISPLAY  
OFF Timer Display Indicator Lights  
CLEAN FILTER Indicator Light  
AUTO Operation Indicator Light  
Odor Sensor  
QUICK CLEAN operation Indicator Light  
POLLEN Mode Indicator Light  
Fan Speed Indicator Lights  
Remote Control Receiver  
Plasmacluster  
Indicator Light  
CLEAN-SIGN Light  
Odor Sensor  
POWER ON/OFF Button See Page E-12  
MODE Selection Button See Page E-12  
Main Unit  
Filter Frame  
Band See Page E-11  
True HEPA Filter (white) See Page E-10,17  
Washable Active Carbon Filter (black)  
See Page E-10,16,17  
Pre-Filter  
Front Panel  
Remote Control See Page E-9,14  
BACK  
Handle  
Air Outlet  
Date Label  
INCLUDED  
Remote Control (1 unit)  
Battery (AA battery x 2 )  
Power Cord  
Power Plug  
• Operation manual  
Download from Www.Somanuals.cEom-.8All Manuals Search And Download.  
PREPARATION  
INSERTING BATTERIES IN THE REMOTE CONTROL  
1 PRreemssoavnedtshliedebtahcekbaccokvceorver to re-  
move.  
2 Insert batteries  
Insert batteries with  
shown below.  
and as  
Close the back cover  
3
Battery Information  
• The battery life is about 1 year.  
• The batteries for this remote control are for initial use only . Change the batteries  
when necessary.  
• Incorrect usage of the batteries may cause battery fluid leakage and/or damage.  
Take care of the following when handling:  
• When replacing the batteries, replace both batteries with new ones of the same  
type. (Use 2 AA manganese batteries.)  
• When not using the unit or remote control for an extended period, remove the  
batteries.  
• The batteries are for initial use only and may be depleted within 1 year.  
REMOTE CONTROL USE  
Operate with the remote control facing the  
main unit receiver.  
The signal range is about 23 feet (7m).  
Make sure there are no objects blocking  
the path of the signal.  
•A beep sound will be heard from the main  
Receiver  
unit when a signal is received.  
Transmitter  
NOTE  
Avoid dropping or damaging the remote  
control, using in a high humidity condition,  
in direct sunlight or near a heat source.  
Download from Www.Somanuals.cEom-.9All Manuals Search And Download.  
PREPARATION  
Be sure to remove the power plug from the wall outlet.  
FILTER INSTALLATION  
To maintain the quality of the filters, they are installed in the main unit within plastic bags.  
Be sure to remove the filters from the plastic bags before using the unit.  
Remove the filters  
1
Remove the Front Panel.  
Pull the bottom of the Front Panel.  
Front Panel  
1
Pull out the Filter Frame and remove  
the Pre-Filter, Active Carbon Filter and  
True HEPA Filter.  
2
Filter Frame  
Pre-Filter  
Remove the ActiveCarbonFilter(black)  
and True HEPA Filter (white) from the  
plastic bags.  
3
Pre-Filter  
True HEPA Filter  
Active Carbon Filter  
Active Carbon Filter  
True HEPA Filter  
Filter Frame  
E-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
True HEPA Filter  
Install the filters  
2
Place the True HEPA Filter  
within the Filter Frame.  
1
Please make sure that the True  
HEPA Filter is placed in proper  
orientation.  
Filter Frame  
Do not install the filter backwards or  
the unit will not operate properly.  
Band  
Place theActive Carbon Filter on  
top of the True HEPA Filter with  
the bands (2 places) facing up.  
Active Carbon Filter  
2
3
True HEPA Filter  
Filter Frame  
Tabs (4 places)  
Place the Pre-filter through  
the bands (2 places) lo-  
cated in the corners of the  
Active Carbon Filter.  
Band  
Insert the tabs of the pre-filter into  
the associated holes of the Filter  
Frame.  
Holes  
Mount the Filter Frame to  
the main unit.  
4
5
Main unit  
Filter Frame  
Band  
Fix the Front Panel to the  
main unit.  
Fill in the usage start date  
on the Date Label.  
6
Use the date as a guide for the  
Filter Replacement schedule.  
Date Label  
E-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Main Unit Controls  
• AUTO  
OPERATION  
• QUICK CLEAN  
• POLLEN  
• SILENT  
• MEDIUM  
• MAX  
MAIN UNIT OPERATION  
Plasmacluster Indicator Light  
CLEAN Filter Indicator Light  
MODE Selection Button  
Power ON/OFF Button  
CLEAN-SIGN Light  
Power ON/OFF Button  
1
2
• Used to start operation (short beep) and stop operation (long beep)  
• Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off.  
• Unless the power cord is unplugged, the operation starts in the previous mode the  
unit was operated in.  
MODE Selection Button  
• The operation mode can be switched.  
AUTO operation  
The fan speed is automatically switched  
(HIGH*, MEDIUM, SILENT) depending  
on the amount of impurities in the air.  
The sensors detect the impurities for  
efficient air purification.  
MAX operation  
The unit will operate at a fan  
speed of MAX.  
QUICK CLEAN operation  
The unit will operate at HIGH* fan speed  
for 15 minutes, then will operate at Auto  
operation.  
The operation mode is effective when  
quick removal of impurities in the air is  
desired.  
MEDIUM operation  
The unit will operate at a fan  
speed of MEDIUM.  
POLLEN mode operation  
SILENT operation  
The unit will operate quietly  
using minimal air intake.  
The unit will operate at HIGH* fan speed  
for 10 minutes, then will alternate  
between MEDIUM and HIGH* for 20  
minutes.  
* HIGH fan speed is an interme-  
diate speed between MEDIUM  
and MAX.  
10 minutes: HIGH fan speed  
20 minutes: MEDIUM fan speed  
20 minutes: HIGH fan speed  
E-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DETERMINING THE BASE IMPURITY RATE  
For the first 30 seconds after the power plug is inserted into the wall outlet,  
the unit will check the conditions of the air. If operation is set to ON during this  
time, the CLEAN-SIGN LIGHT will alternately flash in green, orange and red.  
PLASMACLUSTER INDICATOR LIGHT  
Plasmacluster ion operation is selected using the remote control.  
Blue light  
When the Plasmacluster ion operation is in Clean Mode, or in AUTO  
Plasmacluster Ion Mode and the air in the room is impure, the light will  
activate and the unit will operate in Clean Mode.  
Green light  
When the Plasmacluster ion operation is in the Ion Control Mode, or in  
AUTO Plasmacluster Ion Mode and the air in the room is clean, this light will  
activate and the unit will operate in Ion Control Mode.  
Light off  
There are no Plasmacluster ions being generated.  
• The light can be turned off by using the ‘Lights ON/OFF Button’ on the  
Remote Control. In this case, Plasmacluster ions are generated.  
(Please turn off the light if desired.) (See Page E-14)  
CLEAN-SIGN LIGHT  
The color changes according to the air condition.  
Clean (Green)  
Slightly Impure (Orange)  
Very Impure (Red)  
ABOUT THE CLEAN-SIGN  
• The condition of the CLEAN-SIGN depends on the room air condition  
detected by the Odor Sensors when the plug is inserted into the wall outlet.  
• It is possible to have a green CLEAN-SIGN with impurities in the air at the  
time that the air purifier was just introduced to the room environment. After  
a while, however, the base impurity rate will be adjusted to detect room air  
condition correctly.  
• Use the Lights ON/OFF Button on the remote control to turn off the Indi-  
cator lights if desired.  
CLEAN FILTER INDICATOR LIGHT  
Clean the Active Carbon Filter when the CLEAN FILTER Indicator Light  
activates.  
(The indicator light will activate in about 2 months, when using the unit 24  
hours daily.) (See Page E-16)  
E-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operations available with  
the Remote Control  
OPERATION  
• AUTO  
• MANUAL  
• POLLEN  
REMOTE CONTROL OPERATION  
• OFF TIMER  
• QUICK CLEAN  
• Lights ON/OFF  
Plasmacluster Ion mode  
selections  
• ION AUTO  
POWER ON/OFF Button  
• CLEAN  
• ION CONTROL  
• ION OFF  
• When you press the  
POWER ON/OFF Button,  
a short beep will sound  
and operation will start in  
AUTO Mode.  
Transmitter  
• Unless the power cord has  
been unplugged, the  
operation starts in the  
previous mode the unit was  
operated in.  
Filter Reset Button  
When the WashableActive Carbon  
Filter is cleaned and reinserted into  
the main unit, press the Filter  
Reset Button with a pointed  
instrument such as a pen.  
To stop, press the POWER  
ON/OFF Button again.  
A long beep will sound and  
operation will stop.  
The Filter Indicator light will then  
go out with a beep.  
Off Timer Button  
Auto (Fan Speed) Button  
The set time switches every time  
the button is pressed as shown  
below.  
The fan speed switches au-  
tomatically depending on the  
amount of impurities in the air.  
4 hours  
1 hour  
8 hours  
Cancel  
Manual (Fan Speed) Button  
The fan speed can be  
switched among Silent,  
MEDIUM and MAX settings.  
• The indicator light shows the  
remaining time.  
• The unit will stop operation when  
the time is up.  
QUICK CLEAN Button  
See page E-12  
Pollen Mode Operation  
Button  
See Page E-12  
LIGHTS ON/OFF Button  
Switches the Plasmacluster  
Indicator Light and CLEAN-  
SIGN Light either ON or OFF.  
Plasmacluster Ion Mode Selections  
CLEAN  
ION AUTO  
When pressed, the unit will con-  
stantly operate in the Clean Mode,  
in which the same numbers of posi-  
tive and negative ions are dis-  
charged. The Plasmacluster Indica-  
tor Light is blue.  
When pressed, the unit will switch between Clean  
Mode and the Ion Control Mode automatically de-  
pending on the amount of impurities in the air as  
detected by the dust and odor sensors. Clean  
Mode will operate for 1 minute when theAuto func-  
tion is selected.  
ION CONTROL  
ION OFF  
When pressed, the unit will constantly operate in  
Ion Control Mode.  
The Plasmacluster Ion Indicator Light is green.  
The generation of ions will cease and  
the Plasmacluster Indicator Light will  
go out.  
Download from Www.SomanualsE.co-m1.4All Manuals Search And Download.  
CARE AND MAINTENANCE  
To maintain optimum performance of this air purifier, please clean the unit including  
the sensor and filters periodically.  
When cleaning the unit, be sure to unplug the power cord, and never handle the plug  
with wet hands. Electrical shock and/or bodily injury may occur as a result.  
Odor Sensor  
Main Unit  
True HEPA Filter  
Do not wash the True HEPA Filter.  
Washing will not improve filter performance, and  
it may even cause electric shock or malfunction.  
Washable Active Carbon Filter  
Pre-Filter  
MAIN UNIT  
To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to  
remain, they may become hard to clean.  
Wipe with a dry, soft cloth  
For stubborn stains or dirt, use a soft cloth dampened with warm water.  
Do not use volatile fluids  
Benzene, paint thinner, polishing powder, etc., may damage the surface.  
Do not use detergents  
Detergent ingredients may damage the unit.  
Keep the unit away from water  
ODOR SENSOR  
The sensitivity of the sensor will become  
Opening of odor  
unstable if the sensor is dirty or blocked.  
sensor  
Remove dust from the surfaces of the sen-  
sor openings using a vacuum cleaner.  
PRE-FILTER  
As shown in the figure, clean the top  
surface of the Pre- Filter lightly with a  
vacuum cleaner.  
When Pre- Filter is very dirty, wash it in  
water with mild kitchen detergent and dry  
Pre-Filter well in the shade.  
Pre-Filter  
E-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARE AND MAINTENANCE  
WASHABLE ACTIVE CARBON FILTER CARE  
Dry the filter outdoors  
HAND WASH ONLY!  
5
if possible in a well  
ventilated area.  
DO NOT TUMBLE DRY!  
Care Cycle  
When the CLEAN FILTER Indicator Light lights  
up, this indicates that the filter needs to be  
cleaned. If the unit is kept on 24 hours a day  
then the Filter Indicator Light will activate in  
about 2 months.  
The CLEAN FILTER Indicator Light is for ref-  
erence. Clean the filter as often as necessary  
when odor persists.  
CAUTION  
• The wet filter is heavy. Fix it securely for  
drying to make sure it does not fall down.  
• The filter takes longer to dry in winter, and  
on rainy days. Wash it on a day when the  
weather is good and dry it in the sun.  
Move it indoors at night to prevent freez-  
ing.  
• Dry the filter outdoors in a well ventilated  
area. If dried indoors, the water dripping off  
the filter may soil your floor.  
Fill a large container with warm  
water, add a mild kitchen deter-  
gent and stir.  
1
Dilute as indicated  
on the detergent  
container.  
• Make sure that the activated carbon has  
not shifted to one side inside the filter. If it  
has, distribute it evenly with your fingers.  
• Let the filter dry thoroughly.  
If used while the filter is still moist, then the  
air that is exhausted from the main unit will  
have an odor. It may take 1 or 2 days to dry.  
Allow the filter to soak approxi-  
mately 30 minutes before wash-  
ing.  
2
3
If the filter surface is  
very dirty, scrub with  
an old toothbrush.  
Reinstalling the Filters.  
Reinstall the filters as shown on Page  
E-10,11  
6
Rinse thoroughly with  
clean water.  
7 Connect the power cord to the  
outlet and press the Filter Reset  
Button on the Remote Control  
with a pointed instrument.  
CAUTION  
• Once the Filter Reset Button has been  
activated, you will hear a beep sound  
that means the unit has been reset.  
• The Filter indicator light will then go  
out automatically.  
If rinsing in a container, be  
sure to rinse 3 to 4 times  
so that the odor is rinsed  
thoroughly from the filter.  
Remove excess water.  
Filter Reset Button  
4
The filter will be saturated with water  
after rinsing. To decrease drying time,  
wrap the filter in an old thick towel so  
that excess water can be removed.  
CAUTION  
Some carbon may ad-  
here to the towel, but it  
is harmless.  
E-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FILTER REPLACEMENT GUIDELINES  
The replacement period differs depending on the room environment, the  
usage hours and location of Air Purifier.  
If dust or odors persists, replace the filters.  
(Refer to “Please read before operating your new Air Purifier”)  
Guide for filter replacement timing  
• Filter life can be greatly reduced in poor environments.  
The presence of cigarette smoke, pet dander and other concentrations of airborne particles  
will cause filters to become clogged in less time. Please check filters regulary and replace as  
needed.  
• True HEPA Filter Up to 5 years after opening  
• Washable Active Carbon Filter Up to 5 years after opening  
REPLACING THE FILTERS  
See page E-10,11 for directions on how  
1
to install the filters when replacing.  
After replacing the filters:  
Be sure to press the Filter Reset Button on the Re-  
mote Control with the power cord connected to the outlet.  
A short beep will be heard and the operation hours stored  
in the memory will be reset.  
2
The CLEAN FILTER Light will then go out automatically.  
Fill in the usage start date of the filters  
on the Date Label.  
3
Replacement Filters  
Model: FZ-R45HFU  
• True HEPA Filter : 1 unit  
• Washable Active Carbon Filter : 1 unit  
Date Label  
If you need a True HEPA Filter or a Washable Active Carbon  
Filter only :  
• True HEPA Filter : PFIL-A097KKEZ  
• Washable Active Carbon Filter : PFIL-A098KKEZ  
For replacement filters contact Sharp for information.  
Disposal of Filters  
Please dispose of replaced filters according to the local disposal laws and regulations.  
True HEPA Filter materials:  
• Filter: Polypropylene  
• Frame: Polyester  
Active Carbon Filter Materials:  
• Deodorizer: Activated charcoal  
• Net: Polypropylene 60%, Polyester 40%  
Download from Www.SomanualsE.co-m1.7All Manuals Search And Download.  
TROUBLESHOOTING  
Before calling for repair, please review the list below, since the problem may not be a unit malfunction.  
SYMPTOM  
REMEDY (not a malfunction)  
• Have the batteries been depleted?  
• Are the batteries inserted correctly?  
• Is a fluorescent light in the room flickering due to service life?  
The Remote Control does not  
work  
Odors and smoke are not  
removed  
• Clean or replace the filters if they appear to be heavily soiled.  
(Refer to E-16,E-17)  
The CLEAN-SIGN Light lights  
green even when the air is  
impure  
• The air could be impure at the time the unit was plugged in.  
(Refer to E-13)  
• The sensitivity of the sensors become unstable when the  
opening of the odor sensor is dirty or is clogged.  
Clean the dust around the sensor opening using a vacuum  
cleaner. (Refer to E-15)  
The CLEAN-SIGN Light lights  
orange or red even when the air  
is clean  
The Plasmacluster Indicator  
Light remains green (or blue)  
and does not change  
• When in Clean Mode ( or Ion Control Mode), the Plasmacluster  
Indicator Light color will not change.  
• Clicking sound is emitted when the unit is in the Ion Control  
Mode, and ticking sound is emitted when the unit is generating  
ions.  
A clicking or ticking sound is  
heard from the unit  
If the sound is irritating, set the unit away from you.  
The discharged air has an  
aroma or odor.  
• Check to see if the filters are heavily soiled.  
Clean or replace the filters.  
• Plasmacluster Air Purifiers emit small traces of ozone which  
may produce an odor. These ozone emissions are well below  
safety levels set by FDA.  
The unit does not operate when  
cigarette smoke is in the air.  
• Is the unit installed in a location that is difficult for the sensor to  
detect cigarette smoke?  
• Is the odor sensor opening blocked or clogged?  
(In this case, clean the openings.) (Refer to E-15)  
The CLEAN FILTER Indicator  
Light remains activated even  
after replacing filter.  
• After replacing filters, connect the power cord to an outlet and  
press the Filter Reset Button on the remote control. (Refer to  
E-16)  
• Check to see if the Lights OFF Mode on the Remote Control is  
selected. If so, then press the Lights ON/OFF Button on the  
Remote Control to activate the indicator lights.  
(Refer to E-14)  
The Plasmacluster Indicator  
Light or the CLEAN-SIGN Light  
will not activate.  
ERROR DISPLAY  
LAMP INDICATION  
REMEDY  
The “Silent” Fan Speed Indicator  
Light blinks.  
Fan motor disconnected or abnormal.  
Operation stops.  
• Pressing the POWER ON/OFF button will reset the error  
display, but if error occurs again, contact the shop where you  
purchased the unit.  
Download from Www.SomanualsE.co-m1.8All Manuals Search And Download.  
SPECIFICATIONS  
FP-P40CX  
120V / 60Hz  
MED  
Model  
Power supply  
Fan Speed Adjustment  
Fan  
SILENT  
3.5 W  
MAX  
50 W  
Speed  
Operation  
Rated Power  
7.5 W  
3
Fan Speed CFM (m /min.)  
Applicable Floor Surface  
CADR(Dust/Smoke/Pollen)  
Cord Length  
70 (2.0)  
17 (0.5)  
177 (5.0)  
2
253 sq.ft.* (23.5m )  
157 / 163 / 156  
8.3 ft (2.5m)  
16-3/8 in.(W)x7-7/8 in.(D)x22-7/16 in(H)  
415mm(W)x200mm(D)x570mm(H)  
Dimensions  
Weight  
14.8 lbs (6.7kg)  
* The applicable floor surface area is appropriate for operating the unit at maximum fan speed.  
Standby Power  
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this  
product consumes about 0.3W of standby power.  
For energy conservation, unplug the power cord when the unit is not in use.  
E-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
R
SHARP ELECTRONICS OF CANADA LTD.  
SHARP ELECTRONICS CORPORATION  
Sharp Plaza, Mahwah,  
New Jersey 07430-2135 U.S.A.  
335 Britannia Road East Mississauga,  
Ontario L4Z 1W9 Canada  
SHARP CORPORATION  
Osaka, Japan  
SHARP CORPORATION  
Osaka, Japan  
Printed in China / Imprimé en Chine  
Download from Www.Somanuals.com. All Manuals Search And DownloTadIN. SKA003KKRZ 06H-  

Sharp Air Cleaner FU Y30J W User Manual
Sharp Music Mixer HT SB200 User Manual
Sony DVD Player HT 6800DP User Manual
Sony Flat Panel Television 3 217 284 121 User Manual
Sony Laptop Z505 User Manual
Sony Network Card BTA NW1A User Manual
Sony Portable Radio ICF B200 User Manual
Sparky Group Battery Charger BUR 15E User Manual
Sunbeam Major Appliances Refrigerator Compact Refrigerators
Sun Microsystems Server 220R User Manual