| Retractable Cord Stick Vac   OWNER’S MANUAL   Model EP604   120V., 60Hz., 8.5 Amps.   EURO-PRO Operating LLC   U.S.: 94 Main Mill Street, Door 16   Plattsburgh, NY 12901   Canada: 4400 Bois-Franc   St-Laurent, QC H4S 1A7   Tel. :1 (800) 798-7398   Download from Www.Somanuals.com. All Manuals Search And Download.   Model EP604   IMPORTANT SAFETY INSTRUCTIONS   including the following:   When using your vacuum basic safety precautions should always be observed,   ONE (1) YEAR LIMITED WARRANTY   EURO-PRO Operating LLC warrants this product to be free from defects in material and   workmanship for a period of one (1) year from the date of the original purchase. This warranty   applies only to normal domestic household use.   Should your appliance fail to operate properly while in use under normal household conditions   within the one (1) year warranty period, return the complete appliance and accessories, freight   prepaid to EURO-PRO Operating LLC at the address given below. If the appliance is found to be   defective in material or workmanship, EURO-PRO Operating LLC will repair or replace it free of   charge. Proof of purchase date and $ 12.95 to cover the cost of return shipping and handling must   be included. *   To reduce the risk of fire, electric shock, or   injury:   1. Read all instructions before using your   vacuum.   • • • • Do not leave the vacuum plugged in when   unattended. Unplug the electrical cord   when not in use and before servicing.   Do not allow to be used as a toy. Close   attention is necessary when used by or near   children, pets or plants.   Use only as described in this manual. Use   only manufacturer’s recommended   accessories.   Do not pull cord, use cord as a handle,   close a door on cord, or pull cord around   sharp edges or corners. Keep cord away   from heated surfaces.   Always hold the plug when rewinding the   power cord. Do not allow plug to whip when   rewinding.   Use only extension cords UL-rated or cUL   at 15 amperes. Extension cords rated for   less amperage may overheat. Care should   be taken to arrange the cord so that the cord   cannot be pulled or tripped over.   Turn off all controls as applicable before   unplugging from electrical outlet.   Do not handle plug or vacuum with wet   hands or operate without shoes.   Do not put any objects into openings. Do   not use with any opening blocked. Keep   free of dust, lint, hair and anything else that   may reduce air flow.   2. Use the system only for its intended use.   3. To protect against a risk of electric shock,   do not immerse any part of the system in   water or other liquids.   4. Never yank cord to disconnect from   outlet; instead, grasp plug and pull to   disconnect.   5. Do not allow cord to touch hot surfaces.   6. Do not run appliance over cord.   7. Do not operate the system with a   damaged cord or plug, or if the appliance   or any other part of the system has been   dropped or damaged. To avoid the risk of   electric shock, do not disassemble or   attempt to repair the unit. Return the   system to EURO-PRO Operating LLC   (see warranty) for examination and repair.   Incorrect re-assembly or repair can cause   U.S.:   EURO-PRO Operating LLC, 94 Main Mill Street, Door 16, Plattsburgh, NY 12901   Canada: EURO-PRO Operating LLC, 4400 Bois Franc, St. Laurent, QC H4S 1A7   Non-durable parts including, without limitation, accessories, filters and electrical parts which   normally require replacement are specifically excluded from warranty.   The liability of EURO-PRO Operating LLC is limited solely to the cost of the repair or replacement   of the unit at our option. This warranty does not cover normal wear of parts and does not apply to   any unit that has been tampered with or used for commercial purposes. This limited warranty does   not cover damage caused by misuse, abuse, negligent handling or damage due to faulty   packaging or mishandling in transit. This warranty does not cover damage or defects caused by or   resulting from damages from shipping or repairs, service or alterations to the product or any of its   parts, which have been performed by a repair person not authorized by EURO-PRO Operating   LLC.   This warranty is extended to the original purchaser of the unit and excludes all other legal and/or   conventional warranties. The responsibility of EURO-PRO Operating LLC if any, is limited to the   specific obligations expressly assumed by it under the terms of the limited warranty. In no event is   EURO-PRO Operating LLC liable for incidental or consequential damages of any nature   whatsoever. Some states do not permit the exclusion or limitation of incidental or consequential   damages, so the above may not apply to you.   • • a risk of electrical shock or injury to persons   when the vacuum is used.   8. Close supervision is necessary for any   appliance being used by or near children.   Do not leave the system unattended while   connected.   9. Keep hair, loose clothing, fingers and all   parts of body away from opening and   moving parts.   10. Do not use to pick up flammable or   combustible liquids such as gasoline or use   in areas where they may be present.   11. Do not pick up anything that is burning or   smoking such as cigarettes, matches or hot   ashes.   12. Use extra care when cleaning on stairs.   13. Do not use the vacuum without the HEPA-   Type filter in place.   • • • This warranty gives you specific legal rights, and you may also have other rights which vary from   state to state or province to province.   *Important: Carefully pack item to avoid damage in shipping. Be sure to include proof of   purchase date and to attach tag to item before packing with your name, complete address   and phone number with a note giving purchase information, model number and what you   believe is the problem with item. We recommend you insure the package (as damage in   shipping is not covered by your warranty). Mark the outside of your package “ATTENTION   CUSTOMER SERVICE”. We are constantly striving to improve our products, therefore the   specifications contained herein are subject to change without notice.   • Store your appliance indoors in a cool, dry   area.   Keep your work area well lit.   Keep end of hose, wands and other   openings away from your face and body.   Use only on dry surfaces.   Using improper voltage may result in   damage to the motor and possible injury to   the user. Correct voltage is listed on rating   label.   • • • • ------------------------------------------------------------------------------------------------   OWNERSHIP REGISTRATION CARD   FOR CANADIAN CONSUMERS ONLY   14. This appliance is intended only for   household use. Follow all user instructions   in this manual.   Please fill out and mail the product registration card within ten (10) days of purchase. The   registration will enable us to contact you in the unlikely event of a product safety notification. By   returning this card you acknowledge to have read and understood the instructions for use, and   warnings set forth in the accompanying instructions.   SAVE THESE INSTRUCTIONS   For Household Use Only   Return to: EURO-PRO Operating LLC, 4400 Bois Franc, St. Laurent, QC H4S 1A7   Model EP604   ______________________________________________________________________   WARNING: To reduce the risk of electric shock, this appliance has a   polarized plug (one blade is wider than the other). This plug   will fit in a polarized outlet only one way. If the plug does not fit   fully in the outlet, reverse the plug. If it still does not fit, contact   a qualified electrician to install the proper outlet. Do not modify   the plug in any way.   Appliance model   ______________________________________________________________________   Date purchased   ______________________________________________________________________   Owner's name   ______________________________________________________________________   Name of store   Address   City   Prov.   Postal Code   Rev. 03/05   1 Printed in China   8 Download from Www.Somanuals.com. All Manuals Search And Download.   GETTING TO KNOW YOUR RETRACTABLE CORD   STICK VAC   TROUBLE SHOOTING GUIDE   PROBLEM   POSSIBLE REASON   POSSIBLE SOLUTION   1.   2.   Plug unit in firmly.   Check fuse or breaker. Replace   fuse/reset breaker.   1.   Power cord not firmly plugged into   outlet.   VACUUM WILL   NOT OPERATE   2.   3.   4.   No power in wall outlet.   Needs servicing.   Thermostat has tripped.   3.   4.   Call 1 (800) 798-7398.   Turn the unit off and unplug from   outlet. Allow unit to cool down,   then restart.   1.   2.   Empty and clean dust cup   (container).   VACUUM WILL   NOT PICK-UP OR   SUCTION POWER   IS WEAK   1.   2.   3.   Dust cup (container) is full.   Unit clogged.   HEPA –Type filter needs cleaning   or replacing.   Turn unit off and unplug from   wall outlet. Remove dust cup   (container) and check for   object(s) in air duct and remove.   Clean or replace HEPA-Type   filter.   3.   1.   Empty and clean dust cup   (container).   Review dust cup instructions.   DUST ESCAPING   FROM VACUUM   1.   2.   Dust cup (container) is full.   Dust cup is not installed correctly.   2.   1.   Remove hose and/or brushes.   Remove obstruction from hose   and /or brush.   Empty and clean dust cup   (container).   VACUUM, HOSE   OR BRUSHES   WILL NOT PICK-UP   1.   2.   Hose clogged.   Dust cup (container) is full.   2.   ORDERING REPLACEMENT DUST CUP FILTERS   TO ORDER REPLACEMENT HEPA-TYPE FILTERS   for Model EP604   Call:   1 (800) 798-7398   11. Rear Wheel   1. Handle   Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time   12. Floor Brush   2. Handle Release Button   3. On/Off Switch   4. Carry Handle/Hose Holder   13. Dust Cup (Container)   14. Dust Cup Cover   15. Dust Cup Retainer Handle   FOR TECHNICAL SUPPORT   5. Dust Cup Retainer Handle   16. Crevice Tool   Release Button   for Model EP604   17. Power Cord   18. Easy Grip Handle   6. Cord Rewind Button   Call:   1 (800) 798-7398   7. Dusting Brush   Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time   19. HEPA-Type Filter *not   8. Flexible Hose   illustrated   20. Handle Storage Clip   9. Flexible Hose Holder   10. Floor Brush Release Button   Please Note:   The HEPA-Type filter is washable. It should, however, be replaced every three (3) to   six (6) months to ensure peak performance of your vacuum.   Technical Specifications   Important:   Voltage:   Power:   120V., 60Hz.   8.5 Amps   Make sure that ALL filters have been completely air dried for 24 hours before re-   installing back in the vacuum.   *Illustration may differ from actual product.   2 7 Download from Www.Somanuals.com. All Manuals Search And Download.   OPERATING INSTRUCTIONS   PRECAUTIONARY MEASURES   CAUTION: The suction hole must be   Cleaning & Changing the HEPA-   Type Filter   IMPORTANT: If the suction opening in the unit or the hose is BLOCKED, switch off   the vacuum cleaner and remove the blocking substance before you   start the unit again.   open, free of any obstructions at all   times. Otherwise, the motor will   overheat and could become damaged.   Warning: Always empty the dust cup   container and clean the HEPA-Type   filter before each use and during   prolonged usage.   PLEASE NOTE: The white pleated   filter material in the HEPA-Type dust   cup filter will discolor over time -This   is NORMAL and will NOT affect the   performance of the filter. If the HEPA-   Type dust cup   1. Do not operate the vacuum cleaner   too close to heaters or radiators.   4. When pulling out the power plug   from the wall outlet, pull the plug not   the power cord.   Never over fill the dust cup (container) -   remove dirt and clean the HEPA-Type   filter when dirt in dust cup is at or below   the "MAX" level during prolonged usage   or risk motor damage.   If you wash the HEPA-Type filter,   make sure that it is completely air   dry before inserting back in the   vacuum.   Please Note: The HEPA-Type filter is   washable. It should, however, be   replaced every three (3) to six (6)   months, depending on usage to ensure   peak performance of your vacuum.   filter is properly   "TapCleaned”   Fig. A   after each use   and suction   does not return   to 100%, then   Wash once a   month or when   suction   appears   reduced.   we suggest that   5. Do not pick up anything that is   burning or smoking such as   Warning: Allow 24   the HEPA-Type   2. Before inserting the power plug into   the wall outlet, make sure that your   hands are dry.   hours for air drying   before replacing in unit.   filter be   “TapCleaned”   cigarettes, matches or hot ashes.   vigorously until no   more dust can be removed, then   rinsed under the faucet and allowed to   air dry for 24 hours before refitting into   the vacuum. (Fig. A) Wash once a   month or when suction appears   reduced.   Motor Thermostat   Important: This unit is equipped   with a motor protective thermostat. If   for some reason the vacuum cleaner   should overheat, the thermostat will   automatically turn the unit off. Should   this occur:   Re-Installing Dust Cup (Container)   1. Ensure that small air intake vent   on the dust cup is aligned with the   opening on the main unit. (Fig. 12)   2. Slide the dust cup container into   place and lower the dust cup   retainer handle.   3. Push retainer handle until you hear   it lock into place. (Fig. 13)   3. Before you start vacuuming, make   sure to remove large or sharp objects   that might cause damage to the unit.   6. Do not vacuum any liquids.   7. Do not use without dust cup   (container) or HEPA-Type filter in   place.   • • Push the On/Off button once.   Disconnect the plug from the   power source.   Check the source of overheating   problem. (i.e. clogged hose or   filter)   If clogged hose or filter is found,   unclog the hose and replace the   filters.   • Note: This vacuum cleaner is equipped   with a plug and power cord that retract   automatically. If the cord or plug get   damaged, it must be replaced by a   qualified technician.   • Air Intake   Vent   • • Wait at least 45 minutes before   attempting to reuse the vacuum.   After unit has cooled down for   45 minutes, plug in the cleaner   and push the On/Off button. The   vacuum should start again.   If the vacuum still does not start,   contact customer service at   1 (800) 798-7398.   Warning: Hold the plug when   rewinding the cord. Do not allow the   cord to whip when rewinding.   • Fig. 12   Fig. 13   3 6 Download from Www.Somanuals.com. All Manuals Search And Download.   OPERATING INSTRUCTIONS   OPERATING INSTRUCTIONS   Using Your Vacuum   Assembling Your Vacuum Cleaner   WARNING: Always remove the power   plug from the wall outlet before   Removing / Cleaning the Dust Cup   Cleaning / Replacing the HEPA-   Type Filter   1. To remove the filter cover inside the   dust cup cover, turn counter clockwise   and lift. (Fig. 9)   1. Insert the power plug into the wall   outlet.   Warning: Always unplug the unit from   electrical outlet before opening the dust   cup (container).   Important: Do NOT use the vacuum   without the HEPA-Type filter in place.   Warning: After each Use - Always   remove the HEPA-Type filter and the dust   cup cover, then vigorously “TapClean”   HEPA-Type filter until no more dust can   be removed.   1. To remove the dust cup container,   press on the dust cup retainer   handle release button and lift the   retainer handle upwards. (Fig. 6)   2. Grasp the dust cup from the top, tilt   downwards and pull it out. (Fig. 7)   2. Press the power On/Off button   located on the unit to turn the   vacuum cleaner “On”. (Fig. 4)   assembling or removing accessories.   Attaching The Handle   When removing the unit from   the box, please note that the   handle storage clip is attached   to the handle when it is shipped.   (Fig. 1) Remove the handle   Fig. 9   Fig. 4   Filter Cover   Dust Cup Cover   storage clip and attach it to the   back of the unit onto the clip   mounting slot.   Handle   Storage   Clip   2. To remove HEPA-Type filter, turn filter   counter clockwise and then pull up.   (Fig. 10)   Fig. 1   1. Insert the handle into the hole above   the dust cup handle.   2. Make sure that the slot in the handle   fits correctly into the opening. (Fig. 2)   3. The metal pin should be on the same   side as the handle release button.   Depress the metal pin   HEPA-Type   Filter   3. To rewind the power cord, press the   cord rewind button with one hand   and guide the power cord with the   other hand to ensure that it does not   whip causing damage or injury.   NOTE: Do Not use dust cup handle to   transport the unit, always carry from the   carry handle.   Fig. 10   Dust Cup   Cover   and then firmly push in   3. Hold the HEPA-Type   filter by the edges and   vigorously “TapClean”   the HEPA-Type filter   on a hard, flat surface   until no more dust is   the handle.   4. To remove the handle,   Metal Pin   press the handle   release button and   pull the handle up.   5. Attach the handle   onto the handle   Using The Attachments   1. Remove the long end of the hose   from hose holder.   2. Attach the desired accessory to the   hose. (Fig. 5)   NOTE: The provided accessories can   only be used with the hose. Do not   attempt to attach to the base of the   vacuum.   Fig. 11   observed falling out   Fig. 7   Fig. 6   from between the pleats of the filter.   (Fig. 11)   storage clip if desired.   Attaching The Floor   4. The HEPA-Type filter may also be   washed by running it under the tap   allowing the water to run on the dirty   side. We recommend washing it once a   month or when suction appears   reduced. Always allow 24 hours for air   drying before replacing into the vacuum.   5. Reinstall the HEPA-Type filter into   dust cup cover.   Brush   Fig. 2   1. Insert the floor brush into   its location, in the direction   of the arrow. (Fig. 3)   2. To remove the floor   brush from the vacuum,   press on the floor brush   release button and   3. To empty the dust cup (container),   turn the dust cup cover clockwise.   (Fig. 8)   4. Separate dust cup cover from dust cup   (container).   5. Empty dust cup (container).   6. The dust cup (container) and dust cup   cover can be wiped down with a damp   cloth or rinsed under lukewarm tap   water.   NOTE: Ensure that dust cup (container   and dust cup cover are completely dry   before re-installing into vacuum.   Fig. 5   pull the floor   brush out.   6. Replace the filter cover.   Crevice Tool   For radiators, crevices,   corners, baseboards and   between cushions.   Dusting Brush   Floor Brush   Release Button   The dusting brush is used   for the furniture, Venetian   blinds, lamp shades,   shelves, etc.   Dust Cup   Cover   Fig. 3   Dust Cup   Container   Closed   Fig. 8   Opened   4 5 Download from Www.Somanuals.com. All Manuals Search And Download.   |