Samsung Switch Version 11 User Guide

WEB  
WEB  
TRANSMITTER  
SNS-110 Owner's Manual  
(Version 1.1)  
4
2
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulation Approval  
Note: This equipment has been tested and found to comply with the limits for a  
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are  
designed to provide reasonable protection against harmful interface in a  
residential installation.  
This equipment generates, uses and can radiate radio frequency energy and, if  
not installed and used in accordance with the instructions, may cause harmful  
interference to radio communications. However, there is no guarantee that  
interference will not occur in a particular installation. If this equipment does  
cause harmful interference to radio or television reception, which can be  
determined by turning the equipment off and on, the user is encouraged to try to  
correct the interference by one or more of the following measures:  
- Reorient of relocate the receiving antenna.  
- Increase the separation between the equipment and receiver.  
- Connect the equipment into an outlet on a circuit different from that to which the  
receiver is connected.  
- Consult the dealer or an experienced radio TV technician for help.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Chapter 1. SNS-110 Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6  
Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6  
Functions and Feature - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6  
Names and Function - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8  
Chapter 2. Installing SNS-110 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10  
Setting Configuration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10  
Cautions in Installation- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11  
Unpacking - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14  
Chapter 3. Connecting to Instruments - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - 15  
Connecting to Camera and Video Image Players - - - - - - - - - - - - - - - - - - - - -- - - - - - - 15  
Connecting to External Instruments - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16  
Connecting to Network - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17  
Connecting to Alarm Sensors and External Devices - - - - - - - - - - - - - - - - - - - - - - - - - - 18  
Connecting to PAN/TILT/ZOOM/FOCUS Camera Controller- - - - - - - - - - - - - - - - - - - - - 19  
Connecting to RS-232C - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - 20  
Creating RS-232C Cable- - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 21  
Terminal Emulation Communication Set-up- - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - 21  
Creating Ethernet Cable - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 22  
Chapter 4. Setting an IP Address - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 23  
Before You Begin - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -23  
Setting in Ethernet - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 24  
Setting in Unix - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 26  
Setting with IP Installer - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  
28  
Setting Other Network Information - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 32  
Changing IP Address - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 32  
In Cable Network through Cable Modem - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -33  
Chapter 5. SNS-110 Log-in - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 34  
Ideal Specification - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 35  
Log in through Netscape - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - 34  
Log in through Explorer - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - 35  
Chapter 6. Application Mode (Video Image Monitoring Mode) - - - - - - - - - - - - - - -39  
Initial Screen - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -39  
Single Screen - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 39  
Quadruplex Screen - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -40  
Automatic Sequential Screen - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 40  
Single Screen with PAN/TILT/ZOOM Controllers - - - - - - - - - - - - - - - -- - - - - - - - - - - - 41  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 7. Administration Mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 42  
Initial Screen - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 42  
Camera Set-up - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 43  
PAN/TILT/ZOOM Set-up - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 45  
Quad/Sequential Set-up - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - -46  
Web Transmitter Set-up - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - 47  
Alarm/Relay Set-up - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 50  
Network Set-up - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 52  
File Transter Set-up - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 55  
Custom User Interface Set-up - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 57  
ABOUT/SUPPORT/HELP - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - 58  
?
Appendix A - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -60  
SNS-110 Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -61  
Appendix B - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -64  
Factory Default - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 65  
Appendix C - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -67  
How to use Console - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 68  
Appendix D - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -77  
Dynamic IP Information Transfer - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 78  
Appendix E - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -84  
FAQ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 85  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 SNS-110 Overview  
Overview  
SNS-110, connected to surveillance cameras or other external devices, compresses video image as  
motion JPEG through zip algorithm and transmits it to a remote party through network (Ethernet, cable  
modem).  
SNS-110 may be connected to maximum of 4 video images and concurrently transmits the image in a  
form of single screen, quadruplex screen, or automatic sequential screen.  
Also, this system provides remote users in the Internet with alarm processing function and remote control  
on PAN/TILT/ZOOM/FOCUS, succeeding in an extensive range of applications.  
Functions and Features  
This system transmits real time images at any time with the network (Ethernet, cable modem) present.  
Users in the Internet are not required of additional S/W installation to receive the concurrent video  
images, but may Log-in simply by accessing SNS-110 IP address with the existing web browser (such  
as Netscape or Explorer).  
Users may select a type of screen, among Single Screen, Quadruplex Screen, and Automatic  
Sequential Screen, and also may choose, at his or her preference, transmitting speed and resolution.  
"Automatic Sequential" Screen provides the sequential and automatic changes in  
size of the input images, depending on how the user has set up.  
This system transmits the image to the registered e-mail address at a particular point of time, by  
setting up the alarm.  
Users may conveniently remote-control PAN/TILT/ZOOM/FOCUS under RS485 connection.  
Although the transmitted images are not locked in any way, users may set up ID and access  
password.  
This system is usable regardless of the region because the image broadcasting system (NTSC/PAL) is  
detected and operated with autornatic recognition.  
Auto terminal resistance function automatically withdraws the terminal resistance of 75with the video  
loop (loop through) connection.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
You can send video image files through FTP server at certain time or in regular intervals. Users can  
access the FTP server and search the saved video files.  
You can change the LOGO image on SNS-110 screen, or background color or font colors.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Names and Function  
Familiarize yourself with the names and function of each part on the front and back panels, before  
installing SNS-110.  
Front View of SNS-110  
1
3 4 5 6  
3
4
1.CONTROL 2.F/H 3.Tx R 4.Rx  
R
7
8
9
10  
2
Name  
Function  
Receives input from maximum of 4 video image signals.  
Video In  
Transmit the image output to cameras or other external video-imaging devices  
When connected, the terminal resistance of 75 is automatically seized.  
Video Out  
(Loop Through Out)  
Off : when using as console purpose with RS-232C port connected to a PC  
On : when RS-232C is to be connected to an External Modem.  
Control S/W  
The current version does not support connecting an External Modem.  
Off : use the RS-485 on the reverse side as Half Duplex  
On : use the RS-485 on the reverse side as Full Duplex TX mode  
F H (S/W)  
Off : Tx Termination resistance 120 off  
Tx R (S/W)  
Rx R (S/W)  
On : Tx Termination resistance 120 on  
Off : Rx Termination resistance 120 off  
On : Rx Termination resistance 120 on  
Network LED  
Power LED  
Preset Button  
Reset Button  
Blinks when sending or receiving data with the proper connection.  
Indicates the power on/off.  
Returns to the initial set-up environment of factory default  
Restarts SNS-110 without turning off the power.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rear of SNS-110  
DC 5V  
ETHERNET  
RS-232C  
R/O RX  
TX  
ALARM IN  
RA RC  
1 2  
G
3 4  
G
- + - +  
1
4
2
3
5
6
Name  
Function  
Sensor Input : 1,2,3,4  
Signal GND : G  
Alarm Input(1,2,3,4)  
Connects to maximum of 4 alarm sensors.  
Connected to the external device for remote control  
R/O (Relay Out)  
RA  
RC  
Connects to RS-485 cable and remotely regulate  
PAN / TILT / ZOOM/ FOCUS  
controllers.  
Full Duplex : use RX and TX.  
Half Duplex : use TX .  
RX(+,-)  
TX(+,-)  
RS-485(+,-)  
RS-232C  
Connects to console and an external modem through  
the RS-232C cable connection.  
You are recommended to use the RS-232C  
cable packed with this  
SNS-110.  
The current version does not support  
connecting an External Modem.  
9Pin DSub Connector  
RJ-45 Connector  
Connects to Ethernet (10BaseT/110BaseT) and cable  
modem network.  
Network Port  
Power In  
Supplies the power to SNS-110 with a DC 5V input  
terminal  
Only use the compatible adapter enclosed in  
the SNS-110 package and supply DC 5V.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 Installing SNS-110  
Preparation and installation of SNS-110  
Setting Configuration  
Please, familiarize yourself of the safe condition of SNS-110 installation.  
This product must be horizontally stabilized and not be sloped or vertically positioned. Positioning and  
properly centering its wiring room are crucial for its aptitude function. If the devices are too near with each  
other, or if the ventilation is not sufficient, it may trigger the system malfunction and make its maintenance  
as well as repair difficult to achieve.  
The place must be well ventilated and the case cover must be firmly attached together to avoid system  
malfunction or system shutdown by external factors. Certain inner parts are extremely susceptible to  
abnormal environment, therefore do not open the case.  
SNS-110 must be kept in the place with constant temperature and humidity as indicated below.  
Operation Temperature : 0oC ~ 40oC  
Storage Temperature : -20oC ~ 60oC  
Operation Humidity : 20% ~ 85% RH  
Storage Humidity : 20 ~ 85% RH  
Input Voltage: DC 5V  
Adapter Input Voltage (AC 110 ~ 240V, 50 / 60Hz, 0.5A)  
Adapter Output Voltage (DC +V, 3A)  
Power Consumption : 12 W or below  
Caution  
The fluctuation of operation voltage must be within 10% of the regulation  
voltage, and the electric outlet must be always grounded. Electric heat  
devices, such as, hair dryers, irons, refrigerators, etc., must not be co-used in  
the same outlet with SNS-110. AVR is recommended for stable power supply.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cautions in Installation  
Be aware of the following cautions when installing SNS-110.  
Always turn the power off before SNS-110 installation.  
Severe impact or vibration may cause malfunction.  
Avoid places with strong magnetic or electric field, or places near a radio or TV.  
Always keep the place dust-free when installing or moving SNS-110.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15Cm  
Position it in an open space with flat surface, keeping the  
aptitude temperature.  
Also, maintain the clearance between back of the main body and the wall.  
Be careful not to insert accidentally any conducting material  
in the ventilation space of product.  
Turn the power off and disengage the power cord from the body,  
when changing the circuit-protecting fuse.  
Avoid a direct ray of light, and keep the safe distance between  
crowded place and the product as well as its assemblies.  
The bottom surface must be moisture-free.  
And, be cautious about any possible delicate factors,  
such as ungrounded extension cable, abraded power cord,  
lack of safe grounding.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Do not neglect fumes or unusual odor, which may be symptoms of malfunction.  
When these are identified, please instantly disconnect the power  
and consult to an expert from your local service center.  
NOTE  
Always use a dry cloth when cleaning this product. If the contamination is  
serious, please wipe it first with a neutral detergent, then with a dry cloth.  
Avoid using volatile material, such as alcohol, benzene, or sinner, when wiping  
the surface, due to potential damage on the surface.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Unpacking  
When you purchase SNS-110, after removing the wrap, place the product on a flat surface or where you  
will be installing it.  
Then, check if there is any missing part among the following items.  
SNS-110 Main Body  
User’s Guide  
Power Adapter (1EA)  
Power Cord (1EA)  
RS-232C Cable (1EA)  
4
2
1
SNS-110 Main Body  
User’s Guide  
RS-232C Cable (1EA)  
Power Adapter (1EA)  
Power Cord (1EA)  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3. Connecting to Instruments  
You may connect the following items with SNS-110, such as video image players (e.g., VTR, DVDP, etc.,),  
network devices, alarm sensors, PAN/TILT/ZOOM/FOCUS controllers, and PC-connected consoles.  
No voltage, more than DC 2V, must be connected to the video in/output  
terminal 1~4.  
Caution  
Connecting to Camera and Video Image Players (e.g., VTR, DVDP, TV)  
VTR, DVDP, TV  
OUT  
CAMERA  
3
4
1.CONTROL 2.F/H 3.Tx R 4.Rx  
R
SNS-110 automatically detects NTSC/PAL and transmits it as image signal. Therefore, you may connect  
cameras and video image players (e.g., VTR, DVDP, etc.,) to video terminal 1~4.  
Caution  
Video image players are preferred with identical system when connecting to  
Video In/Out 1~4. The miscellaneous usage may decrease the resolution of  
certain broadcasting system.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting to External Instruments  
VTR, DVDP, TV  
OUT  
CAMERA  
3
4
1.CONTROL 2.F/H 3.Tx R 4.Rx  
R
VIDEO IN  
External Device  
SNS-110 produces the video image signal of the corresponding channel, if connected with external  
instruments to Video Out 1~4 (loop through BNC). The terminal resistance of 75will be automatically  
seized by the connection with external instruments.  
External Device  
Surveillance control units : Frame Switcher, Quad Switcher, Sequential Switcher, Multi-plexer, Monitor, etc.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting to Network  
Ethernet(10BaseT/100BaseT)  
DC 5V  
ETHERNET  
RS-232C  
ALARM IN  
R/O RX TX  
1
2
G
3
4
G
RA  
RC  
-
+
-
+
RJ- 45 Ethernet Cable(Direct)  
HUB  
INTERNET  
Back Bone  
Cable Modem  
DC 5V  
ETHERNET  
RS-232C  
ALARM IN  
R/O RX TX  
1
2
0
3
4
0
RA  
RC  
-
+
-
+
RJ- 45 Ethernet Cable(Direct)  
Cable Modem  
Cable Network  
INTERNET  
Back Bone  
CMTS  
(Cable Modem Termination System)  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting to Alarm Sensors and External Devices  
ALARM IN  
R/O RX  
TX  
RA RC  
- + - +  
1 2  
G
3 4  
G
S
S
S
E
N
S
O
R
3
S
G
N
D
G
N
D
E E  
N N  
E
N
S
S
S
O O  
R R  
O
R
4
1
2
Function  
Alarm In  
Name  
Regular Capacity  
Alarm 1/2/3/4/G  
-TTL Level(5VDC)  
-Initial Contact Resistance, Max. : 75m§  
-Max. Switching Power : 60W, 62.5VA  
-Max. Switching Voltage : 220VDC/125VAC  
-Max. Carrying Current : 2A  
Relay Out  
RA/RC  
-Contact Rating(Resistive) : 2A 30VDC/0.5A 125VAC  
Alarm sensors and external devices are usable by connecting to ALARM IN and R/O terminals of the reverse  
side of the SNS-110 respectively.  
Caution  
When connecting an external device to R/O terminal, you are recommended to use  
additional “Relay” for the purpose of the protection of each device.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting to PAN/TILT/ZOOM/FOCUS Controller  
RX-  
RX+  
P/T/Z/F Controller 1  
P/T/Z/F Controller 2  
R/O  
ALARM IN  
RX TX  
RX-  
RA RC  
1 2  
G
3 4  
G
- + - +  
RX+  
RX-  
RX+  
P/T/Z/F Controller 3  
P/T/Z/F Controller 4  
RX-  
RX+  
The RX/TX terminal of the reverse side of the SNS-110 uses the RS-442/485 interface and  
PAN/TILT/ZOOM/FOCUS controllers can be connected to the terminal.  
The PAN/TILT/ZOOM/FOCUS controllers that are supported are the following.  
Samsung Smart-Dome Camera (SCC-641) Pelco : Pelco-P Protocol Support Control  
Sungjin Electronic Communications : CPU-Receiver  
When connecting Samsung Smart-Dome Camera (SCC-641), you have to connect the  
SNS-110 to the TxDt, - terminals of SCC-641. In this case, the supportable Baud Rate  
Note  
is 38400 and 19200bps. For more detail information, please refer to the user manual  
of SCC-641.  
Reference inquire the shop at which it was purchased for the products other  
that the above PAN/TILT/ZOOM/FOCUS camera and controllers.  
The TX+ and TX- of the terminal as shown in picture, is connected to the external terminal of the  
PAN/TILT/ZOOM/FOCUS controller, and generally the external terminal has a +,- polarity indication so be  
sure not to switch the polarity.  
Set the F/H Switch to On (knob faced down) on the front side of the SNS-110.  
Refer to the PAN/TILT/ZOOM/FOCUS controller manual and confirm & reset the following items.  
Baud Rate  
Data Bit  
Stop Bit  
Parity Bit  
Controller ID (be careful not to duplicate a different controller ID)  
Caution  
If several PAN/TILT/ZOOM/FOCUS controllers are used, they must be the same  
models.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting to RS-232C  
When connecting PC serial port (COM1, COM2) through RS-232C from back of SNS-110, you may  
select console mode of SNS-110 by using PC terminal emulation program (HyperTerminal).  
Control S/W from the front panel must be positioned "OFF".  
Caution  
In the console mode, if you change the existing data improperly, the system  
may result in serious problems.  
Pin Number  
Name  
Direction  
RS - 232C Terminal (D-Sub 9Pin)  
1
2
3
4
5
6
7
8
9
NC  
TxD(Transmit Data)  
Output  
Input  
RxD(Receive Data)  
NC  
SG(Signal GND)  
Power  
NC  
NC  
NC  
NC  
RS - 232C Connecting to Cable  
DC 5V  
ETHERNET  
RS-232C  
ALARM IN  
R/O RX TX  
1
2
0
3
4
0
RA  
RC  
-
+
-
+
RS - 232C Cable  
Terminal  
Emulation  
Program  
Serial Port  
(COM1, COM2)  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Creating RS-232C Cable  
The RS-232C Cable is packed with SNS-110, and so you don’t need to make it .  
The wiring diagram shown below is for your information.  
9Pin Female to 25Pin Female  
1
1
14  
6
9
2
3
2
3
5
7
25  
13  
9Pin Female to 9Pin Female  
1
6
2
1
2
3
6
9
3
9
5
5
Terminal Emulation Communication Set-up  
Items  
Contents  
Baud Rate  
Data Bit  
38400 bps  
8 Bit  
Parity  
None  
Stop Bit  
1 Bit  
Flow Control  
Data Code  
None  
ASCII  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Creating Ethernet Cable  
Since the Ethernet Cable is not packed with SNS-110, the user has to purchase and use it .  
Connected from SNS-110 to Hub (Direct Cable)  
1
1
8
8
RJ - 45  
RJ - 45  
DC 5V  
ETHERNET  
RS-232C  
ALARM IN  
R/O RX TX  
1
2
G
3
4
G
RA  
RC  
-
+
-
+
Direct  
Ethernet Cable  
Web Browser  
HUB  
INTERNET  
Back Bone  
Connected from SNS-110 to PC(Twisted Cable)  
1
1
8
8
RJ - 45  
RJ - 45  
DC 5V  
ETHERNET  
RS-232C  
ALARM IN  
R/O RX TX  
1
2
G
3
4
G
RA  
RC  
-
+
-
+
Twisted  
Ethernet Cable  
Web Browser  
LAN Card  
RJ-45 Port  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4 Setting an IP Address  
No information upon network is set up except Ethernet address (MAC address) in factory defaults. You  
must set up the IP address when installing.  
Caution  
Ethernet address (00-00-f0-XX-XX-XX) is recorded on the bottom of the  
product at the time of purchase. Because it may be accidentally erased,  
please duplicate the number and keep it somewhere else.  
Before You Begin  
(1) Confirm the Ethernet address (00-00-f0-XX-XX-XX) on the bottom of SNS-110. You must keep this  
number for IP address set-up.  
(2) Confirm the normal power supply of SNS-110.  
(3) Confirm the proper connection with network.  
When properly connected to network with Ethernet environment, the front network LED blinks.  
(4) To use your SNS-110 under the Ethernet(10BaseT/100BaseT) environment, an unused IP address  
must be assigned to SNS-110 from a network manager.  
At this time, check the following network related information.  
IP Address  
Gateway  
Subnet Mask  
Domain Name  
DNS  
(5) If you set up an IP address through DHCP server in network environment, and if SNS-110 is  
properly connected to network, you will automatically be assigned with an IP address, gateway, and  
subnet mask by turning the power on. Confirm this auto-assigned IP address from RS-232C  
connected PC terminal emulation (HyperTerminal).  
Please, refer to  
"
Connecting to RS-232C  
"
and APPENDIX C "How to Use Console".  
Refer to the Appendix D, "Dynamic IP information Transfer" to send Dynamically Assigned IP  
Address to the administration server.  
(6) Set up an IP address, according to network environment as following.  
You must appropriately set up an IP address abiding by your network environment.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting In Ethernet (10BaseT/100BaseT)  
For Windows 95/98/ME/NT/2000/XP  
(1) Open Dos window from network-connected PC with SNS-110.  
(2) Execute "arp -s".  
arp -s <SNS-110 IP Address> <SNS-110 Ethernet Address>  
Example :  
arp -s 168.219.15.250 00-00-f0-ff-a1-0a  
(3) Confirm if the IP address completely agrees with Ethernet address as shown below by executing "arp -a".  
arp -a  
Example :  
arp -a  
Internet Address  
168.219.15.249  
168.219.15.250  
Physical Address  
00-00-f0-ff-a1-2b  
00-00-f0-ff-a1-0a  
Type  
static  
static  
If does not completely agree after pursuing (2), delete the present IP address by executing "arp -d"  
and repeat (2) and (3).  
arp -d <SNS-110 IP Address>  
Example :  
arp -d 168.219.15.250  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(4) Wait until you receive the normal response after executing "ping".  
ping <SNS-110 IP Address> - 110 -n 20  
You must enter it.  
Example :  
ping 168.219.15.250 - 110 -n 20  
Pinging 168.219.15.250 with 32 bytes of data:  
Request timed out.  
Request timed out.  
No Response  
Request timed out.  
Request timed out.  
Reply from 168.219.15.250: bytes=110 time=1ms TTL=255  
Reply from 168.219.15.250: bytes=110 time=1ms TTL=255  
Reply from 168.219.15.250: bytes=110 time=1ms TTL=255  
Reply from 168.219.15.250: bytes=110 time=1ms TTL=255  
Reply from 168.219.15.250: bytes=110 time=1ms TTL=255  
Reply from 168.219.15.250: bytes=110 time=1ms TTL=255  
Normal  
Response  
(5) If you are getting no response, attempt 1~2 more times. If you are still not getting any response,  
please refer to APPENDIX D "FAQ".  
Caution  
You must only use the PC within identical Gateway with IP address, when  
setting up IP address in Ethernet.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting in Unix  
(1) Execute the following instruction for network-connected Unix machines with SNS-110.  
(2) Execute "rarp -s".  
rarp -s <SNS-110 IP Address> <SNS-110 Ethernet Address>  
Example :  
rarp -s 168.219.15.250 00:00:f0:ff:a1:0a  
(3) Confirm if the IP address completely agrees with Ethernet address as shown below by executing "rarp - a".  
rarp -a  
Example :  
rarp -a  
IP Address  
HW Type  
HW Address  
168.219.15.249  
168.219.15.250  
10Mbps Ethernet  
10Mbps Ethernet  
00-00-f0-ff-a1-2b  
00-00-f0-ff-a1-0a  
If does not completely agree after pursuing (2), delete the present IP address by executing "rarp - d"  
and repeat (2) and (3).  
rarp -d <SNS-110 IP Address>  
Example :  
rarp -d 168.219.15.250  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(4) See if you receive the normal response as shown below after executing  
ping <SNS-110 IP Address>  
"ping".  
Example :  
ping 168.219.15.250  
PING 168.219.15.250 (168.219.15.250): 56 data bytes  
64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms  
64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms  
64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms  
64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms  
64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms  
64 bytes from 168.219.15.250: icmp_seq=0 ttl=255 time=1.1ms  
^c  
(5) If you do not get responses, type "Ctrl+C" to stop and try number (4) couple of more times to re-  
execute. If you still do not get response, refer to the APPENDIX "D."  
Caution  
You must only use the PC within identical gateway with IP address, when  
setting up an IP address in Ethernet.  
For detailed information, refer to APPENDIX E. FAQ "No response to PING  
when setting the IP address".  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting with IP Installer  
The 'IP Installer' is an application program that supports easy setting of network parameters of SNS-110 such  
as IP Address, Gateway, Subnet Mask and so on. Before executing the 'IP Installer', the SNS-110 should be  
connected with PC through RS-232C cable. The 'IP Installer' works on Windows 95/98/ME/NT/2000/XP.  
Program Name of IP Installer : SetupWebTX_v11.exe  
Note  
You can download the 'SetupWebTX_v11.exe' at 'http://www.samsungelectronics.com'.  
(1) Download the 'SetupWebTX_v11.exe' and install your PC.  
(2) Connect SNS-110 with PC through RS-232C cable. Please refer to the 'Connecting to RS-232C' of  
Chapter 3.  
Caution  
Please identify which serial port is assigned for the connection of SNS-110 among  
COM1/COM2 of PC.  
When connecting the SNS-110 with PC, use the RS-232C cable included in the package of  
SNS-110.  
You have to confirm the assigned serial port not to be used simultaneously by other devices  
such as modem or mouse.  
(3) When executing the 'IP Installer' after the installation, you will see the following window. Select the serial  
port what you assigned for the connection of SNS-110, and then click the "OK" button.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note  
If the serial port which you select is being used by other device, you will see the following  
window.  
In this case, you have to stop the usage of serial port by other device or change the  
connection of SNS-110 to other serial port.  
(4) If the SNS-110 and PC is successfully connected through RS-232C cable, you will see the following  
window.  
(5) In obedience to the 'Comments' of the program, reset SNS-110 by pushing the 'RESET' button or by  
turning off and on of SNS-110. Then, the present state of network parameters of SNS-110 will be  
displayed.  
If nothing is displayed in the program, check the serial connection of SNS-110 and PC, and then repeat  
the above procedure.  
Note  
For more detail information of the network parameters, please refer to the 'Network Set-up' of  
Chapter 7.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(6) Set up or modify the network parameters, and then click the 'OK' button.  
(7) If the setting of network parameters succeeds, you will see the following window.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(8) After the setting of network parameters, the SNS-110 will automatically reboots.  
If all of the network parameters are properly set, you can connect SNS-110 with Web Browser.  
Note  
If the 'success' message window does not appear even though you wait more than 10  
seconds after clicking 'OK' button, stop the program by clinking 'Cancel' button. And then,  
execute the "SetupWebTX_v11.exe' and follow above processes again.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Other Network Information  
After successfully setting up the IP address in Ethernet, follow the next procedure to set up additional  
network information.  
After the previous procedure, you must set up the following information, confirmed by the network  
manager, to connect to network successfully.  
Gateway  
Subnet Mask  
Domain Name  
DNS  
(1) Open a web browser (Netscape or Explorer) from the network-connected PC or Unix machine with  
SNS-110 installed.  
(2) Log-in with the SNS-110 IP address set up through the web browser. You must enter the exact ID and  
password.  
The initial user name and password are shown below.  
User Name : root  
Password : w2000  
(3) After logged in, set up the additional network information in administration mode.  
(4) Be sure to reset or switch off and then switch on your SNS-110 after setting.  
Note  
Please, refer to Chapter 5 and 7 for Log-in and administration mode network  
setting up.  
Changing IP Address  
(1) To change the present IP address, log in with the present IP address. Then, change the IP address  
in network set-up of administration mode.  
Refer to Chapter 7. setting Administration Mode Network.  
(2) Refer to APPENDIX B "Factory Default", to set up the factory default and set up a new IP address  
according to Chapter 4, Setting an IP Address.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In Cable Network through Cable Modem  
(1) Connect according to  
"Connecting to Cable Modem" of Chapter 3 Connecting to Network, and turn  
the SNS-110 power on.  
(2) SNS-110 automatically receives the following information from the cable network manager by  
executing DHCP (Dynamic Host Configuration Protocol), if connected to cable network through a  
cable modem.  
IP Address  
Gateway  
Subnet Mask  
(3) Please confirm the auto-assigned IP Address from PC terminal emulation (HyperTerminal) connected to  
RS-232C.  
Please, refer to  
"
Connecting to RS-232C  
"
and APPENDIX C "How to Use Console".  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 5 SNS-110 Log-in  
After successfully setting up an IP address as in Chapter 4, execute a web browser (Netscape or  
Explorer) from an Internet PC.  
Ideal Specification  
If your PC performance is not compatible, the image processing speed will decrease in your web browser,  
resulting in possible short-image.  
Also, incompetent PC performance may cause PC abnormal function because of PC resource parts.  
Therefore, use  
CPU: Pentium II more than.  
Main Memory: 64 MByte or more.  
Because low web browser version also may cause problems in image processing, use  
Netscape 4.0 or higher version  
Explorer 4.0 or higher version  
Note  
There may be problems with video image transfer if Netscape 6.0 or above is  
used, so use a version below 6.0  
Log-in through Netscape  
(1) Open Netscape web browser.  
(2) Enter the SNS-110 IP address in Go to : xxx.xxx.xxx.xxx  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(3) If you have properly logged in, you will see the following.  
(4) Properly enter user name and password and click "OK" button. You should see the initial screen of  
Chapter 6 Application Mode.  
Log-in through Explorer  
First Time  
(1) If you have never logged in through Explorer, first download plug-in program from SNS-110.  
Then, follow the next procedure.  
(2) Open the Explorer web browser.  
(3) Select "Tools" from top menu of the browser. And, select "Internet Options", then "Security".  
Make sure the security level is set at "Medium" or lower. If not, please select "Confirm", after selecting  
"Medium" or lower.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(4) Enter the SNS-110 IP Address in Address : xxx.xxx.xxx.xxx  
(5) If you have properly logged in, you will see the following.  
(6) Properly enter user name and password and click  
Then, you should see the security message.  
"OK" icon.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(7) Click  
"Yes". You just have completed downloading Explorer plug-in program from SNS-110.  
Then, you will see the initial screen of Chapter 6, Application Mode.  
(8) If security level is set to  
installed.  
"High",then the following window appears and the program cannot be  
Therefore, go back and set the security level to "Medium" or lower.  
Warning  
After the Explorer download completes, please place the security level in its  
original position.  
After the First Time  
(1) Open Explorer web browser.  
(2) Enter SNS-110 IP address in Address : xxx.xxx.xxx.xxx  
(3) If you have properly accessed "Log-in" window appears.  
(4) Properly enter user name and password and click "OK" button.  
You should see the initial screen of Chapter 6 Application Mode.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Others  
(1) The initial user name and password in factory defaults are as follows.  
User Name : root  
Password : w2000  
(2) Log-in window appears only under the following condition.  
When "Password Enable" is set in the Web Transmitter setting of the Administration mode and you  
have access to the Application mode, Log-in window appears.  
The factory default is "Password Enable".  
When "Password Disable" is set in the Web Transmitter setting of the Administration mode and you  
have access to the Administration mode, Log-In window appears.  
The access to the Administration mode is restricted because it is used to change SNS-110  
configuration.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 6. Application Mode (Video Image Monitoring Mode)  
Initial Screen  
(1) If you have entered correct user name and password or clicked  
next initial screen of application mode.  
"Application" button, you will see the  
(2) You will see the quadruplex screen with 4-video image input. And, without any image input, you will  
see No Video  
"
"
Single Screen  
(1) By selecting an image from "Camera 1~4" button on left side of the screen, you will see individuals  
image corresponding to your selection.  
(2) Click the present image number to refresh.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quadruplex Screen  
(1) Click "Quad" button on left side of the screen.  
You will see 4 individual screens in the quadruplex screen.  
(2) Click any of the 4 screens to view it in single screen.  
Automatic Sequential Screen  
(1) Click "Sequential" button on left side of the screen in Application mode.  
You will see 4 screen sequentially altering. The interval time between each screen can be regulated  
in Administration mode.  
(2) Screen configuration is set as in single screen condition.  
Caution  
The video quality in Quad/Sequential screen may be inferior, because the  
transmitted video quality is set to be as in single screen.  
If you view an image with Quad/Sequential screen in normal size, after setting  
the single screen as Size Small/Video Quality High, the video quality is inferior  
to when you view the single screen with Size Normal/Video Quality High.  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Single Screen with PAN/TILT/ZOOM Controller  
(1) After enabling PAN/TILT/ZOOM in Administration mode, if you select an image from "Camera 1~4"  
button, you will see the next screen.  
(2) Before operating PAN/TILT/ZOOM, the PAN/TILT/ZOOM controllers must have been connected, and  
P/T/Z configuration must have been established in Administration mode.  
(3) You will see scrolling bars around the image. You may select your preferred angle and position of the  
image by clicking each bar. To move the camera to the presaved position, select the position in the box  
on the left bottom of screen.  
(4) To stop moving the image after clicking the control bar, click "" in the center of the bar to seize the  
image.  
Differences do exist depending on the types of PAN/TILT/ZOOM controller.  
Sluggishness may occur in the image due to the time duration in network.  
(5) If you click  
4 images.  
"Quad" button on left side of the screen in Application mode, you may simultaneously view all  
(6) To transfer from Application mode to Administration mode, click  
of the screen.  
"Administration" on the left upper corner  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 7 Administration Mode  
Initial Screen  
(1) You must enter "root" for the user name and its password in the Log-in window to transfer to the  
below Administration mode screen for both password-enable and password-disable condition.  
(2) If the camera does not operate normally after accessing to the Administration mode, the camera icon  
that is located on the screen blurs. If the camera operates normally, however, the icon shows in gray.  
(3) You may set up PAN/TILT/ZOOM, Quad/Sequential, Web Transmitter, Alarm, and Network by  
clicking each corresponding Icon.  
If setting is not correctly done or many persons set at the same time in the  
Note  
Administration mode, this product may malfunction. So be careful to manage  
the Log-in password in the Administration mode and it is recommended that  
only the person who manages this product can use the product.  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Camera Set-up  
(1) You will see the following screen by clicking "Camera" icon in Administration mode.  
(2) Camera Input  
Automatically recognizes image broadcasting system (NTSC/PAL), Color/Black &white, or No Video.  
If you click Refresh button at any time, this function will run through and set up new configuration of  
image broadcasting system (NTSC/PAL), Color/Black &white, or No Video.  
"
"
(3) Size  
As the size of image in the screen, you may select  
"
Small  
",  
"
Normal  
", or "Large".  
(4) Video Quality  
Select one of  
"Low",  
"
Medium  
", and "High".  
(5) Text Display  
In the purpose of displaying the title for each image, you may type the text in English or Korean.  
If you click "Yes", the text is printed on the corresponding image.  
Recommend  
You can improve the transmitting speed, which is decreased by distal network  
or traffic, by reducing the size or quality of image.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(6) PAN/TILT/ZOOM  
Select Disable  
inactivated.  
If Pan/Tilt/Zoom are properly connected, select  
"
"
, if Pan/Tilt/Zoom controller is not connected. At this time "Preset" button is  
"Enable".  
(7) Preset  
It will activate  
"Preset" button. At this time, you will see the next screen, and you may remotely  
control the position of camera.  
After positioning the camera as your preference with Pan/Tilt/Zoom/Focus controllers, save this  
position in  
"
Current Position  
". This saved position is to be selected in the future by clicking "Preset"  
button in Application mode.  
The coordinate of saved position is saved in Selection Box of Preset Position in Preset Page.  
You can delete it by clicking "Remove" button, after selecting the name in Selection Box.  
(8) Apply to  
The initial coordinate only applies to particular camera input, such as  
Camera 4  
If you select  
apply to the displayed texts.  
"
Only Camera 1  
"
~
"Only  
".  
"
All Cameras", the selected information applies to all 4 cameras. This function does not  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PAN/TILT/ZOOM Set-up  
(1) You will see the next window, if you click "P/T/Z" icon in administration mode.  
(2) Device  
To control PAN/TILT/ZOOM/FOCUS, connect the PAN/TILT/ZOOM/FOCUS camera & controller to the  
+, - terminals of RS-485 on the rear of your web transmitter. For further information, refer to Chapter 3.  
"Connecting to PAN/TILT/ZOOM/FOCUS Camera & Controller".  
Here are the supported PAN/TILT/ZOOM/FOCUS camera & controller.  
Smart Dome Camera & Controller, made by Samsung Electronics  
P Protocol Dome Camera and Receiver, made by PELCO  
CPU Receiver, made by Sungjin Electronics  
If you have a device other than Pan/Tilt/Zoom/Focus controller that is currently  
Note  
supported, contact your vendor.  
(3) Baud Rate  
Set up appropriate Baud Rate depending on the type of controller.  
(4) Data Bit  
Select Data Bit from either 7Bit or 8Bit, depending on the type of controller.  
(5) Stop Bit  
Select Stop Bit from either 1 Bit or 2 Bit, depending on the type of controller.  
(6) Parity Bit  
Select Parity Bit from Odd, Even, or None, depending on the type of controller.  
(7) Camera Identity  
Maximum of 4 PAN/TILT/ZOOM/FOCUS controllers may be connected. When connecting more than  
one controller, you must assign an ID for each controller. Please, refer to the controller manual for its ID.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quad/Sequential Set-up  
(1) You will see the next screen by clicking Quad/Sequential icon in Administration mode.  
(2) Quad Size  
Select from either Small or Normal.  
(3) Sequential Size  
Select one from Small/Normal/Large.  
(4) Sequential Interval  
You may select the sequential interval from 3secs to 60secs. Your selected time will be the interval between  
4 input images in the sequential screen.  
(5) System  
Select the image broadcasting system between NTSC and PAL, depending on where you are. SNS-110 is  
designed to select automatically the image broadcasting system from the input image signal.  
If you miscellaneously use different systems, such as NTSC and PAL, SNS-110 processes the image size  
according to the system set-up in quad and sequential screen.  
Recommend  
You are recommended to use identical type of image signal, because video  
quality may decrease or malfunction, if you use different type of signals in 4-video  
input.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Web Transmitter Set-up  
(1) You will see the next configuration window by clicking "Web Transmitter" in Administration mode.  
(2) Date & Time  
Select date and time.  
(3) Security  
New root pswd  
Changes root password. New password must be more than 3 letters and less than 32, and must  
include Arabian numbers.  
Every time you log in to Administration mode, you have to enter user name and password, and  
only valid password is "root" password.  
User Name and Password  
You may restrict the access from other users by registering user name. User name must be less  
than 32 letters, and password must be more than 3 letters, and less than 32, and must include  
numbers.  
When you want to delete the registered user name, select the user name in  
"Delete User" and  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pswd Enable  
Restricts the access from other users. If you check the check box of "Pswd Enable" and click  
"Apply" button, you should input registered username and its password in Log-in window to  
access to the Application mode.  
If you don’t check the check box of  
"Pswd Enable", anyone is accessible to the Application mode.  
Caution  
Anyone, who is accessible to Administration mode, may change configuration  
of SNS-110. If the configuration is deleted or altered, the system may be  
damaged or malfunction. Therefore, factory default is set up with root  
password.  
After the initial installation, you are strongly recommended to change the root  
password and restrict the access from other users.  
(4) S/W Upgrade  
Upgrade the currently installed program in SNS-110 to the most updated version.  
Download the updated program version from Samsung Electronics web site .  
program is sns110_vXXX_XXXX.bin.  
Save the updated program version in the directory of SNS-110-connected PC.  
Click  
"Browse" and select the updated program, sns110_vXXX_XXXX.bin, in the directory.  
The selected file will be saved in the browse window.  
Click  
"
Install  
"
and open dialog window. You will see caution message, then click "OK" to start  
program upgrade. Upon the upgrade completion, you will see another dialog window. You must  
wait approximately for 2 minutes.  
Caution  
Wait until the "Upgrading is successful! New code will be loaded after  
reset" message appears. Rebooting SNS-110 before this message can  
cause fatal damage to the machine.  
Reboot SNS-110 after the upgrade being completed as shown below.  
Press Reset button on the front panel.  
"
"
Turn off and then on SNS-110.  
After successfully upgrade the program, execute web browser and Log-in.  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Caution  
Be careful not to install any other file except SNS-110 program  
(sns110_vXXX_XXXX.bin) during S/W upgrade. You might accidentally trigger  
the fatal system damage. Always reboot, after the system is upgraded.  
After upgrading, Network setting (IP Address, DNS ) is not changed but the  
user s input is initialized after rebooting and it has to be specified at  
Administration Mode.  
(5) Factory Default  
If you click "factory default" button, all information or configuration of SNS-110 will return to the point of  
purchase, except Ethernet address. Refer to APPENDIX B "Factory Default" for details.  
Caution  
Be careful when you execute “Factory Default”, because all configuration of  
SNS-110 will return to the initial state, and it disables the Log-in.  
(6) Software Reset  
Reset the SNS-110 through Network.  
Caution  
The ‘Software Reset’ will disconnect all of the present connections of SNS-110.  
Right after the S/W upgrade, ‘Software Reset’ doesn’t work.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting the ALARM / RELAY Out  
(1) Connect the alarm sensor to another device according to the ‘Chapter 3 Connecting to Instruments’.  
The alarm level of the alarm terminal 1~4 is the following.  
Normal condition : TTL High Level (DC 5V)  
Alarm : TTL Low Level (DC 0V)  
(2) If the alarm is set off the SNS-110 sends video images connected to alarm terminal 1~4, by E-mail or  
to the FTP server on a set time gap. 5 frames for E-mail and 999 frames for FTP can be transferred,  
and the E-mail with preset messages and video images can also be transferred.  
(3) In the Administration Mode this settings window will be seen with a click on the "Alarm/Relay" icon.  
(4) Status  
The present status on the Relay Out terminal of the reverse side of the SNS-110. The toggle shaped  
"Turn On/Off" button is used to control the external device connected to the Relay Out terminal.  
(5) Sender  
In order to send alarm messages and video images by E-mail, the E-mail address must be entered so  
as to identify the sender. If the E-mail address is invalid the alarm messages and the video images  
may not be sent as wanted.  
Please, set the valid e-mail address of SNS-110 administrator at e-mail the ‘sender’.  
Recommend  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(6) Enable  
Each alarm terminal has to be set as for whether the "Mail" or "FTP" transfer function is going to be  
used. If the alarm sensor isn't installed or if the input signal can be ignored, click "No".  
(7) Pre-alarm  
If the video image transfer is set to FTP and the alarm went off, this will send the images that were  
sent before the alarm. The number of the video images that is sent before the alarm is equal to the  
'Image No.' in item (12), and if the Image No. surpasses 32, then a maximum of 32 frames will be  
transferred.  
(8) Receiver  
This sets the E-mail address that will receive the alarm messages and the video images when the  
alarm goes off. It is used when the 'Mail' is set in item (6).  
(9) Subject  
This sets the 'Subject' of the alarm message, and 30 characters can be entered. It is used when the  
'Mail' is set in item (6).  
(10) Message  
This sets the alarm message it self, 30 characters can be entered. It is used when the 'Mail' is set in  
item (6).  
(11) Camera  
This sets the image that will be transferred among Camera 1~ 4 when the alarm goes off.  
(12) Image No.  
This sets the page number of video images received. If the 'Mail' in item (6) is set, the mail No. is,  
if the FPT is set the FTP No. is used. Mail can be used 1~ 5, and FTP 1~ 999.  
(13) Time Delay  
This sets the time gap while the still image is received. If is set for "2 seconds", it transfers one  
captured cut of still image every 2 seconds and the figure set in item (12) is the number of repetition.  
When set to "None", no time gap is used and the still image is captured and transmitted by the SNS-  
110 with its highest ability.  
Caution  
If the attached file is blocked or the size is limited when sending an image file on the  
SMTP server, the alarm messages and the video images may not be transferred.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Network Set-up  
(1) You will see the next configuration window by clicking "Network" in Administration mode.  
(2) IP Address  
Enter SNS-110 IP Address. If the IP Address has been properly set up according to Chapter 4 Setting  
up IP Address, the IP Address will automatically be set up and shown in the window.  
If the IP Address is changed in use, re-set the IP Address on this menu. .  
(3) HTTP Port  
Set the Http Port to connect to a web browser. Default setting is at 80.  
(4) DNS (Domain Name Server)  
Set up the DNS server address assigned from the network manager and the address must be in  
alphabet letters including numbers and "."  
(5) Domain Name  
Set up Domain Name address assigned by the network manager.  
(6) Subnet Mask  
Set up the Subnet Mask Address assigned by the network manager.  
(7) SMTP (Simple Mail Transfer Protocol) Server  
Set up the IP Address of mail server, where the message will be sent to when the alarm is raised.  
The SMTP Server should support the e-mail address which is set at the  
‘Sender’ of Alarm/Relay Out.  
Caution  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(8) Gateway  
Set up the Gateway Address assigned by the network manager.  
(9) DHCP (Dynamic Host Configuration Protocol)  
DHCP is protocol, which automatically assigns IP address in network environment.  
Those network environments automatically assigned with IP Address are as follows.  
Set DHCP "Yes" at Ethernet, which uses DHCP Sever.  
Also set DHCP "Yes" at Cable Network.  
DHCP must be "NO" in the network environment besides the above two cases.  
Click "Advanced" to notify the Dynamic IP address through mail or to register with  
separate DB server. Refer to the "Appendix" for the further information.  
Caution  
If DHCP is set to "Yes" in the network environment, in which you manually  
receive the IP address from the network manager, the Log-in condition may  
be unsatisfactory during power on/off. Or, if DHCP is set to be "No" in the  
network environment, which automatically assigns IP address to users, such  
as Cable Network, the IP address may not be assigned to your terminal during  
power on/off. When these do happen, please refer to FAQ section.  
(10) Please, set up DHCP to appropriate network environment, when you want to change your network.  
Then, turn the power off and connect to the network.  
Change DHCP "No" to "Yes" when you change Ethernet (manually assigned IP environment) to Cable  
Network Ethernet (dynamically assigned IP Network environment).  
Change DHCP "Yes" to "No" when you change Cable Network, Ethernet (dynamically assigned IP  
Network environment) to Ethernet (manually assigned IP environment).  
Note  
The basic form of internet address is xxx.xxx.xxx.xxx and xxx is a number  
between 0~ 255.  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(11) FTP Server  
Specifies the FTP Server address to send still image. The server address has to  
be either network IP Address where SNS-110 can access or Host Name.  
(12) FTP Port  
Set the FTP Port to transfer still images to the FPT server. Default setting is at 21.  
(13) User  
Specifies the User ID to access FTP server.  
(14) Password  
Specifies the User Password to access FTP server.  
(15) Directory  
Specifies the server Directory to save the image sent through the FTP server.  
Such characters like \ / * : ? " < > | cannot be entered.  
Caution  
To send image through the FTP server, specify a user who is authorized  
to access the FTP server to create directories and upload files. The FTP  
server has to be specified to create multi-level directories, if not, sending  
images may not successfully work.  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
File Transfer Setting  
(1) Click "File Server" at Administration Mode to open the following window and to specify  
the file transfer through the FTP server.  
(2) Camera 1~4  
Specifies the FTP transfer for input image from Camera 1 to Camera 4. Click "No" not  
to use FTP transfer, click "Once" to transfer at one certain time a day, and click  
"Every" to send in regular time gap for certain period of time. Click "Both" to use both  
functions of "Once" and "Every."  
(3) Once  
Specifies the time to transfer image files. It only applies to the files which were set as  
"Once" or "Both" at (2). Specify "Time"(0~23), "Minute"(0~59), or "Second"(0~59) to  
transfer the image files through FTP server at set time. Each transferred files are  
saved at respective cameras and Date Directories. For example, at Network Setting, if  
you specify a directory as WebTxImage to save FTP server to send an image file at  
Camera 1, at 10:12:15, the file is saved as the following file format.  
~/WebTxImage/ch1/20001101/101215-once.jpg  
~/WebTxImage/ch1/20001102/101215-once.jpg  
....  
(4) Every  
Specifies the number of frame per hour to transfer image files. It only applies to files  
which were set as "Every" or "Both" at (2). You can set desired number of frame or  
time value or time unit, and set from 5 frames per second to 1 frame per 24 hours.  
Click "No Delay" to transfer at the maximum speed.  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(5) Between  
Specifies the starting and finishing time of image file transfer. It only applies to files  
which were set as "Every" or "Both" at (2). You can set "Time"(0~23), "Minute"(0~59),  
or "Second"(0~59). If starting and finishing time are identical, image files are  
transferred all day.  
(6) Day  
Specifies days to transfer image files. It only applies to files which were set as "Every"  
or "Both" at (2). You can choose the days for "Every" mode transfer. If "Everyday" is  
checked, all the values under "Everyday" is ignored.  
(7) Filename  
Specifies file names. It only applies to file which were set as "Every" or "Both" at (2). If  
you chose "Overwrite mode," files are overlapped to the specified names. If you  
choose "Save mode," transferred files are being saved in each "Camera", "Date",  
"Time" Directory. For example, at Network Setting, if you specify a directory as  
WebTxImage to save FTP server to send an image file at Camera 1, at every 10  
seconds, the file is saved as the following file format.  
~/WebTxImage/ch1/20001101/10/105940.jpg  
~/WebTxImage/ch1/20001101/10/105950.jpg  
~/WebTxImage/ch1/20001101/11/111000.jpg  
....  
Click "Save" to transfer after specifying all the correct values.  
If Alarm is raised while the image files by "Once" or "Every" mode are  
being transferred through the FTP server, the transfer by "Once" or  
"Every" mode is standby until the Alarm Image Transfer is done.  
The image is continuously transferred after the Alarm Image Transfer is  
completed.  
Caution  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Custom User Interface Setup  
(1) By clicking the "Web Browser" icon in the Administration Mode, the Custom User  
Interface setting window appears. Start page, page title, background color, font color  
and language can be set up, as the user wants.  
(2) Start Page  
The start page in the Application Mode allows a choice between one of Camera 1~4,  
Quad, and Sequential.  
(3) Page Title  
Here the contents and the application of the Title String, which falls under the Page  
Header of HTML, is set. The title that is typed in here is indicated on the title bar of the  
Web Browser. If "No" is selected, the inputted characters are ignored and is set to  
default.  
(4) Background Color  
The background color of the HTML is set and asks for application. The color constant  
(i.e. Black, Red...) or the RGB (i.e. #9aabab) can be entered. If "No" is selected, the  
inputted characters are ignored and is set to default.  
(5) Text Color  
The color of the characters on the screen is set and asks for application. The input  
method is the same as done in item (4). If "No" I selected, the inputted characters are  
ignored and is set to default. The color of the character with an icon image format  
cannot be changed.  
(6) Custom Logo URL  
The address of the image file that will be used for the logo is set here. The full  
address and file name has to be entered  
If the indicated image file is unreadable, it will not be seen on the browser. Click  
"No" to ignore the inputted characters and apply default settings.  
(7) Language  
English and Chinese can be used as the GUI language of the SNS-110.  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ABOUT/ SUPPORT/ HELP  
(1)ABOUT  
Provides you information on SNS-110.  
(2)SUPPORT  
Search for an webTX or SNS-110, and you can download SNS-110 user manual, a last update program  
and troubleshooting instructions.  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(3 )HELP  
Provides you with help messages on each function.  
You can see help message as shown below by clicking  
mode.  
in the configuration window of Administration  
?
Ex) the Help that appears when the  
is clicked on the Camera setting window.  
?
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WEB  
A
APPENDIX  
SNS-110 SPECIFICATIONS  
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX A SNS-110 SPECIFICATIONS  
SPECIFICATIONS  
Video In/Out  
Composite 4 Channel, Color & Black/White  
NTSC/PAL compatible  
BNC Type  
Loop Through Out  
1.0 Vp-p, 75 Hi Z Termination type  
Hardware  
32Bit RISC CPU  
2MByte Flash Memory  
32MByte SDRAM  
Operation System  
RTOS (Real Time OS)  
Network Interface  
10BaseT Ethernet  
100BaseT Fast Ethernet  
Cable Modem  
Image Compression  
Motion JPEG  
Protocol  
TCP/IP, ARP, HTTP, FTP, SMTP, DHCP  
Resolution  
Mode  
Size  
NTSC  
PAL  
Single  
Small  
Normal  
Large  
176X120  
352X240  
704X480  
176X136  
352X272  
704X544  
Quad  
Small  
Normal  
176X120X4  
352X240X4  
176X136X4  
352X272X4  
Sequential  
Small  
Normal  
Large  
176X120  
352X240  
704X480  
176X136  
352X272  
704X544  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance  
Max 30 Frame/Sec (1 User Single Mode Connection)  
Alarm In  
Input 4 Port  
TTL Level "Low" Active  
Sends the Video screen through E-mail/FTP in case when alarm sets off  
Pre-Alarm  
Relay Out  
Output 1Port  
Regular Capacity of Relay  
- 2A 30VDC  
- 0.5A 125VAC  
Serial Connector  
RS-232C 1 Port (9 Pin D-Sub): Console  
RS-485 1 Port (Terminal Block): PAN/TILT/ZOOM Control  
Installation & Software Upgrade  
IP Configuration : ARP, DHCP Protocol, Using RS-232C Cable  
Software Upgrade : RFC 1867  
Web Browser  
Netscape 4.0 or more (Currently we have problems with supporting Netscape 6.0 or more)  
Explorer 4.0 or more  
Security  
Password Protection  
Deviation of programmed clock  
± 30 Sec/Month or less  
Environment  
Operating Temperature: 0oC ~ 40oC  
Storing Temperature: -20oC ~ 60oC  
Operating Humidity: 20% ~ 85% RH  
Storing Humidity: 20% ~ 95% RH  
Power  
Input Rating: AC110 ~ 240V, 50 ~ 60Hz, 0.5A  
Output Rating: DC+5V, 3A  
Power Consumption: 12 Watts  
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulation Approval  
Note: This equipment has been tested and found to comply with the limits for  
a Class B digital device, pursuant to part 15 of the FCC Rules. These limits  
are designed to provide reasonable protection against harmful interface in a  
residential installation.  
This equipment generates, uses and can radiate radio frequency energy and,  
if not installed and used in accordance with the instructions, may cause  
harmful interference to radio communications. However, there is no  
guarantee that interference will not occur in a particular installation. If this  
equipment does cause harmful interference to radio or television reception,  
which can be determined by turning the equipment off and on, the user is  
encouraged to try to correct the interference by one or more of the following  
measures:  
- Reorient of relocate the receiving antenna.  
- Increase the separation between the equipment and receiver.  
- Connect the equipment into an outlet on a circuit different from that to  
which the receiver is connected.  
- Consult the dealer or an experienced radio TV technician for help.  
Outside view  
+
+
-
R C R A G  
G
2
1
3
4
-
T X  
R X R / O  
A L R A M  
A L A R M I N  
1.CONTROL 2.F/H 3.Tx  
R
4.Rx  
R
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WEB  
B
APPENDIX  
Factory Default  
64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX B Factory Default  
Factory Default sets the program back to the condition at the time of purchase.  
Please note that after Factory Default has been enabled, network information is also deleted, so establishing  
a connection is impossible. Refer to Chapter 4, Setting an IP Address, in order to set a new IP address.  
How to Enter the Factory Default  
(1) Power on the SNS-110 or push the ‘Reset’ button in front of the SNS-110 while pushing the ‘PRESET’  
button. Then the Power LED of SNS-110 turns on and off just one time. The turn state of Power LED  
says that the progress of Factory Default is going on. Hole on pushing the ‘Reset’ button.  
(2) When the progress of Factory Default cornplete, the Power LED turns on again.  
Stop pushing ‘Reset’ button.  
(3) All the setting of SNS-110 returns as the state of purchase.  
Values for setting up SNS-110  
Items  
Factory Default Value  
Camera 1~4  
Camera Input  
Size  
Blank  
Normal  
Low  
Video Quality  
Text Display  
PAN/TILT/ZOOM  
Apply to  
Blank/No  
Disable  
Only Cemera 1~4  
P/T/Z  
Device  
None  
Baud Rate  
2400  
Data Bit  
8
Stop Bit  
1
Parity Bit  
None  
Camera 1 ldentity  
Camera 2 ldentity  
Camera 3 ldentity  
Camera 4 ldentity  
Quad Size  
0
1
2
3
Quad/  
Normal  
Sequential  
Sequential Size  
Sequential Interal  
System  
Normal  
3
NTSC  
Web  
Date & Time  
Security  
2001/January/1 00:00:00  
Administration ID:root/Password:w2000  
User ID: guest 1/Password:guest1  
Password Enable  
Transmitter  
Software Upgrade  
Blank  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Items  
Alarm /  
Relay Out  
Factory Default Value  
Relay Out Status  
Sender  
Off  
Blank  
No  
Enable  
Receiver  
Subject  
Blank  
Blank  
Blank  
Message  
Camera  
Camera 1,2,3,4  
Image No.  
Time Delay  
IP Address  
HTTP Port  
DNS  
Mail : 1/ FTP: 10  
None  
Network  
0.0.0.0  
80  
0.0.0.0  
Domain Name  
Subnet Mask  
SMTP Server  
Gateway  
DHCP  
Blank  
0.0.0.0  
Blank  
0.0.0.0  
Yes  
FTP Server  
FTP Port  
User  
0.0.0.0  
21  
Blank  
Password  
Directory  
Blank  
Blank  
File Server Camera1  
Camera2  
Camera3  
Camera4  
Once  
No  
No  
No  
No  
0:0:0  
Every  
1frames/1Minute  
Between  
Day  
0:0:0 and 0:0:0  
Everyday  
Filename  
cam  
Web  
Start Page  
Quad  
Browser  
Page Title  
Web Transmitter-Samsung Electronics/(No)  
Background Color  
Text Color  
#b8b8b8/(No)  
Black/(No)  
logo.gif/(No)  
English  
Custom Logo URL  
Language  
Warning  
All network-related information but Ethernet Address will be deleted.  
Therefore, you must be extremely careful when you execute this function.  
66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WEB  
C
APPENDIX  
How to Use Console  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX C How to Use Console  
Console allows condition check-up of SNS-110 by connecting to RS-232C port, manually setting network-  
related information.  
Starting Console  
(1) Connect to RS-232C port on the PC in accordance with  
Connecting other equipments”  
"
Connecting to RS-232C  
"
of "Chapter 3,  
(2) Use Terminal Emulation (Hyper Terminal) from the connected PC to set the values for RS-232C  
through Terminal Emulation.  
(3) The following message will appear when you turn on the power of SNS -110.  
Message  
(1) When the power is turned on, the following message will appear on the console screen when  
SNS-110 has been successfully installed.  
########################################################  
#
#
#
#
#
#
#
#
#
#
SAMSUNG Electronics. Co., Ltd.  
webTX(Internet Video Server):SNS-110  
Version1.1(2000~2001) All Rights Reserved.  
########################################################  
>Current status is Flash Memory Boot  
>To change system parameter, press any key within 2 seconds  
....IP:168.219.13.11  
If any key is pressed within two  
seconds, manual setup mode  
will appear.  
3, SM:255.255.255.192, GW:168.219.13.65  
>Web Transmitter Image Loading<  
>Ethernet(MAC) address in Cookie : [00-00-f0-ff-a1-ba]  
>Network parameters in gstrIP, gstrSubnetMask, gstrGtwyIP  
-IP:168.219.13.113 SM:255.255.255.192 GW:168.219.13.65  
>Network Interface Installed  
Indicates Ethernet address  
Indicates IP address, Subnet  
Mask, and Gateway  
>DNS IP address is empty or invalid  
************************* HttpPort = [80]  
************************* FTP port = [21]  
Initializing External Devices... (f_InitExtDev())  
EXTACON0 = 06110a59, EXTACON1 = 00000000  
Timing COS/ACS/COH/ACC : 1315 1203 0000 0000  
init universal timer(#1), 1ms period  
system has 4 decoder(s).  
all decoders/channels are reset.  
rtc init step skipped.  
Rtc time : 2001/1/1 [Mon] 04:06:17  
Indicates the time elapsed with  
SNS-110  
reflected os time : 2001/01/01 04:06:17  
JpegRESET: write reg 0 <- 0 fail. a0 read  
Jpeg reset ok.. loading..  
Jpeg header size : 591 (0x24f) bytes  
68  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Codec initialized, register updated.  
Create/Start working tasks... (f_CompVideo())  
JCPY task start (id=1638400)  
AlarmCheck task start (id=1703936)  
Mailing task start (id=1769472)  
PTZ control task start (id=1835008)  
Create FTPClientTask.. Enter the loop.  
Create PreAlarmTask.  
All Task started.  
Wait until jpeg task ready...  
Launch Webcontrol server as new thread.  
WebServer task created. now starting..  
>Relay Status : 0  
wt_cookie initialized.  
SetCrsz 0x1111 : 01 01 01 01  
using Cam Size/CR Info from FLASH 0x1111  
WT_PSWD : cookie->user_count=2  
WT_PSWD_AddEntry: NEW <uid=root, pswd='w2000', mem=0x76063c>  
WT_PSWD_AddEntry: NEW <uid=guest1, pswd='guest1', mem=0x76053c>  
WT_PTZ: PTZ driver [0x4e] 'None'  
dummy ptz dirver inited.  
user cmd: 'ptz' registered.  
ftp server addr invalid.  
End of WT_FTP_INIT  
All modules initialized.  
****************************************************************  
*
Internet Video Server : webTX SNS-110  
*
*
*
*
* -System Version sns110.1.1 (Build 01.10.16.13.55)  
* -WebServer Version 3.1  
Indicates the software version  
loaded on SNS-110  
* -OCX Version 1.0.1.6  
****************************************************************  
MAIL: Mailing Loop enter..  
Alarm-port checking Task started.  
Alarm check period : 100 ms, current alarm IO: 0x000080e0  
ftp server addr invalid.  
End of WT_FTP_INIT  
PTZ control task started.  
>Log In :  
(2) When you correctly enter user name "root" and password, the following message will appear.  
>Log In : root  
>Password :  
>Welcome to SAMSUNG webTX SNS-110  
SNS-110>  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Command  
(1) help: Indicates Command items  
SNS-110> help  
telnet  
ping help status tftpdn reset freset jpgtest  
SNS-110>  
(2) ping: Indicates the connection status to a given IP Address  
SNS-110> ping 168.219.13.115  
ping (168.219.13.115): 56 data bytes  
168.219.13.115 is alive  
SNS-110>  
(3) status: Indicates the current condition and information of SNS-110  
SNS-110> status  
size of data = 2144  
SNS-110 System Parameter List  
Version sns110.1.1 build 01.10.16.13.55  
********** Board Parameters **********  
Compiled option : Codec external bank, FIFO external bank I/O  
********** Cookie Parameters **********  
Active cookie 0x51e0000 (37), stamp 78  
Backup cookie 0x51f0000 (38), stamp 77  
cookie base : 0x051e0000, cookie size : 3896  
--System  
version of system : sns110.1.1, webserver : 3.1, ocx : 1.0.1.6  
buildtime : detected 01.10.16.13.55, cookie report 110.1.0.170  
--Network parameter  
Mac : <00-00-f0-ff-a1-ba>, IP : <168.219.13.113>  
Netmask : <255.255.255.192>, gateway : <168.219.13.65>  
SMTP : <>, DNS : <>  
HTTP port : 80  
tftp server : <> / <rom.bin>  
DHCP : off, BOOTP : off, RARP : on  
70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
--User information  
number of user : 2  
user list  
0 <root:w2000:10>  
1 <guest1:guest1:1>  
--Camera setting  
Cam1 : size 1, CR 0, title off, <>  
Cam2 : size 1, CR 0, title off, <>  
Cam3 : size 1, CR 0, title off, <>  
Cam4 : size 1, CR 0, title off, <>  
Quad size 1, Quad mode 0, Seq size 1, Seq interval 1  
Cam ptz control 0 0 0 0  
User password enabled (1)  
--Alarm parameter  
alarm1 no, rcv addr , sender addr , camera 1, 0/10 images, interval 0  
subject <>, message <>  
alarm2 no, rcv addr , sender addr , camera 2, 0/10 images, interval 0  
subject <>, message <>  
alarm3 no, rcv addr , sender addr , camera 3, 0/10 images, interval 0  
subject <>, message <>  
alarm4 no, rcv addr , sender addr , camera 4, 0/10 images, interval 0  
subject <>, message <>  
--P/T/Z parameter  
driver : <None>  
serial : 2400 bps, data 8, stop 1, parity 0  
ptz address 0 1 2 3  
ptz preset setting list  
(0) id0, name <None>  
total 0 menu.  
--FTP parameter  
server:<> user:<> pass:<>  
dir:<>  
FTP port : 21  
enable 0 0 0 0 once 0:0:0  
every 1 min, betw 00:00:00~00:00:00, day 1  
--Dynamic IP  
reg enabled, server:<> cgi:</cgi-bin/webtx.cgi?regist=%e&host=%i>  
mail enabled, addr:<[email protected]>  
--User Interface  
title disabled, <WebTransmitter - Samsung electronics>  
bgcolor disabled, <#b8b8b8>  
txtcolor disabled, <black>  
logo disabled, <logo.gif>  
********** DHCP network parameters **********  
system boot with fixed IP saved in NVRam  
----  
SNS-110>  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(4) tftpdn : Using the ftp Server, software can be downloaded as the following.  
First the tftpdn Server has to be running on the PC with the new software.  
The tftp Server isn't offered separately. Users must use their own tftp server programs.  
SNS-110> tftpdn  
****************************************************************  
*
Main Image Download & Flash Update by TFTP  
*
****************************************************************  
>TFTP Server(Default:0.0.0.0) : 168.219.13.101  
>TFTP Server : 168.219.13.101(0xa8db0d65)  
>Download File(Default:rom.bin) and 'q' to exit) : rom.bin  
>Download File : rom.bin  
Enter the IP address of the tftp  
Server  
Enter the filename of the  
software that will be  
downloaded from the tftp Server  
>Main Image Download & Buffering  
BBBBBBBBBBBBBBBBBBBBBBBBBBBBB  
>Transfered 956560(0xe9890)Bytes  
The software is being  
downloaded from the tftp  
Server  
>Unlock Flash Block  
UUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUU  
>Erase Flash Block(B0~B21 0xe9890Bytes)  
EEEEEEEEEEEEEEEEEEEEEE  
>Write Flash Block(0xe9890Bytes)  
The downloaded software is  
being written on the Flash  
Memory  
PPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPP  
>Lock Flash Block  
LLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLL  
>Cookie Validate [168.219.13.113] [00-00-f0-ff-a1-ba] [255.255.255.192]  
>Main Image Download & Flash Update Complete  
SNS-110>  
(5)reset: SNS-110 »Reset ˆ¯·ˇ· .  
SNS-110> reset  
reset after 0 second.  
SNS-110> Reset requested!!! reset after 1 ms  
>Application shutdown  
###############################################################  
#
#
#
#
#
#
#
#
#
#
SAMSUNG Electronics. Co., Ltd.  
webTX(Internet Video Server):SNS-110  
Version1.1(2000~2001) All Rights Reserved.  
###############################################################  
>Current status is Flash Memory Boot  
>To change system parameter, press any key within 2 seconds ....  
72  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(6) freset : the SNS-110 settings are initiated for factory shipment  
SNS-110> freset  
Setting HTTP port to 80 and FTP port to 21.  
>Application cookie field initialized.  
Cookie App field initialized.  
ftp server addr invalid.  
For complete erase, use PRESET button.  
End of WT_FTP_INIT  
SNS-110>  
Manual Configuration Mode  
(1) Once you turn the power on and SNS-110 functions normally, the following message will appear,  
and if you press any key, you will be able to set the values manually.  
########################################################  
#
#
#
#
#
#
#
#
#
#
SAMSUNG Electronics. Co., Ltd.  
webTX(Internet Video Server):SNS-110  
Version1.1(2000~2001) All Rights Reserved.  
########################################################  
>Current status is Flash Memory Boot  
Press any key at this stage.  
>To change system parameter, press any key within 2 seconds ...  
The following message appears if you do not press Space Bar or Enter. This is to wait for the reception of  
the IP Address, which is transmitted through network.  
########################################################  
#
#
#
#
#
#
#
#
#
#
SAMSUNG Electronics. Co., Ltd.  
webTX(Internet Video Server):SNS-110  
Version1.1(2000~2001) All Rights Reserved.  
########################################################  
>Current status is Flash Memory Boot  
>To change system parameter, press any key within 2 seconds  
....IP:0.0.0.0, SM:0  
.0.0.0, GW:0.0.0.0  
>Web Transmitter Image Loading<  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
>Ethernet(MAC) address in Cookie : [00-00-f0-ff-a1-ba]  
>Forced to use DHCP for IP address setting(DHCP Flag=0x1)  
>Stored IP address <00000000> is not valid!  
>RARP(Fixed IP) Mode -> Try to find IP : Retry No.[1]  
>Ethernet(MAC) address in RARP mode : [00-00-f0-ff-a1-ba]  
.....  
>DHCP(Dynamic IP) Mode -> Try to find IP : Retry No.[1]  
.....  
>RARP(Fixed IP) Mode -> Try to find IP : Retry No.[2]  
>Ethernet(MAC) address in RARP mode : [00-00-f0-ff-a1-ba]  
.....  
>DHCP(Dynamic IP) Mode -> Try to find IP : Retry No.[2]  
.....  
To go to the next level, go over to the number (1) after re-running SNS-110. When you successfully  
entered Space Bar or Enter, the following screen appears.  
(2) When the following message appears by running the above item, you can manually set the  
information relating to Network.  
--------------------------------------------  
[WEB Transmitter(SNS-110) Version 1.1]  
Boot command Loop menu  
--------------------------------------------  
[p] Print Boot Parameters  
[c] Change Boot Parameters  
[q] Quit Menu  
-------------------------------------------  
Select items? [ ]  
(3) If you enter "p" at "Select items?", you can access the network information.  
Select items? [ ] p  
----------- SNS-110 Parameters-------------  
ip address: 0.0.0.0  
Ethernet address: [00-00-f0-ff-a1-ba] (41402)  
Subnet mask address: 0.0.0.0  
SMTP Mail server: NULL  
DNS Server address: 0.0.0.0  
Gateway address: 0.0.0.0  
Domain Name: NULL  
74  
Download from Www.Somanuals.com. All Manuals Search And Download.  
tftp server address: 0.0.0.0  
tftp boot file:[rom.bin]  
DHCP Enabled:[1]  
IP auto-reg server:[NULL]  
IP auto-reg cgi:[/cgi-bin/webtx.cgi?regist=%e&host=%i]  
IP auto-reg enable:[1]  
IP notify-mail address:[[email protected]]  
IP notify-mail enable:[1]  
--------------------------------------------  
[WEB Transmitter(SNS-110) Version 1.1]  
Boot command Loop menu  
--------------------------------------------  
[p] Print Boot Parameters  
[c] Change Boot Parameters  
[q] Quit Menu  
-------------------------------------------  
Select items? [ ]  
(4) If you enter "c" when "Select items?" appears, you will be provided with the menu, which will allow you  
to manually set the network information.  
Select items? [ ] c  
[ WEB Transmitter ( SNS-110 ) Version 1.1 ]  
Boot parameters modification menu  
--------------------------------------------  
[i]. Ip address modify  
[s]. Subnet mask address modify  
[m]. SMTP mail server address modify  
[d]. DNS server address modify  
[g]. Gateway address modify  
[n]. Domain name modify  
[1]. IP auto-regist server address  
[2]. IP auto-regist cgi format  
[3]. IP auto-regist enable/disable  
[4]. IP notify-mail enable/disable  
[5]. IP notify-mail address  
[c]. dhcp flag modify  
[q]. Quit menu  
--------------------------------------------  
Select items? [ ]  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(5) If there is information you would like to change or update, you can do so at this time.  
Select items? [ ] i  
LAN IP address? [0.0.0.0] 168.219.13.113  
168.219.13.113  
Turning off DHCP mode....  
Warning  
To use the Static IP Address, put "0" for DHCP flag and to use the Dynamic IP  
Address, put "1." The default is "1" but when you change IP Address, DHCP flag is  
automatically changed to "0." Confirm for more accurate setup.  
(6) If you enter "q" when "Select items?" appears, you will go back to menu of (2).  
(7) If you enter "q" when " Select items?" appears, SNS-110 will boot, and Network will be set to the  
values you have assigned.  
76  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WEB  
D
APPENDIX  
Dynamic IP Information  
Transfer  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix D Dynamic IP Information Transfer  
In such an environment where you have to be assigned with Dynamic IP as Cable Modem,  
you need separate method since users cannot know IP information. SNS-110 uses two  
methods to show the Dynamic IP information to users. One is to send IP information to the  
administrator’s email, and the other is to send the Dynamic IP information to the  
Administration server.  
For this function to properly work, SMTP, DNS, or Gateway have to be all properly set.  
When you cannot access through the browser, refer to the Appendix C and set at the  
console.  
To send IP information to the administrator E-mail  
When you are assigned with Dynamic IP through DHCP, you can send the assigned IP  
Address through email. When you cannot access through the browser at the first setting,  
use the following method to use the console.  
Run the Boot Command Mode as explained in Appendix C, "Manual Configuration Mode"  
and choose "Change Boot Parameters" menu.  
--------------------------------------------  
[WEB Transmitter(SNS-110) Version 1.1]  
Boot command Loop menu  
--------------------------------------------  
[p] Print Boot Parameters  
[c] Change Boot Parameters  
[q] Quit Menu  
-------------------------------------------  
Select items? [ ] c  
[ WEB Transmitter ( SNS-110 ) Version 1.1 ]  
Boot parameters modification menu  
--------------------------------------------  
[i]. Ip address modify  
[s]. Subnet mask address modify  
[m]. SMTP mail server address modify  
[d]. DNS server address modify  
[g]. Gateway address modify  
[n]. Domain name modify  
[1]. IP auto-regist server address  
[2]. IP auto-regist cgi format  
[3]. IP auto-regist enable/disable  
[4]. IP notify-mail enable/disable  
[5]. IP notify-mail address  
[c]. dhcp flag modify  
[q]. Quit menu  
--------------------------------------------  
Select items? [ ]  
78  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Enter "5" and go to IP notify-mail address to type E-mail address you want.  
Select items? [ ] 5  
IP notify-mail address? [[email protected]] [email protected]  
Enter "4" and go to IP notify-mail enable/disable and enable it.  
Select items? [ ] 4  
IP notify-mail enable? [Y]  
Select Quit menu to exit Boot Command Mode.  
When all the network settings are properly installed and DHCP function is enabled, Dynamic  
IP information is sent to the email, which was set while SNS-110 was booting. The following  
is what happens when the email is sent  
From: WebTransmitter  
Subject: IP Notification (168.219.44.137)  
New IP 168.219.44.137 is obtained by DHCP. 00-00-f0-ff-a1-ff  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Registering IP information with Administration server  
Install HTTP server, which can process the Properties transmitted by SNS-110, or  
receive separate service from the Service Provider to register IP information with  
Administration server. Dynamically assigned IP information can only be set at SNS-110,  
whether which name or server will be used. If you cannot access the browser, use the  
console to set up.  
Run the Boot Command Mode as explained in Appendix C, "Manual Configuration  
Mode," and select "Change boot parameters" menu.  
##########################################################  
#
#
#
#
#
#
#
#
#
#
SAMSUNG Electronics. Co., Ltd.  
webTX(Internet Video Server):SNS-110  
Version1.1(2000~2001) All Rights Reserved.  
##########################################################  
>Current status is Flash Memory Boot  
>To change system parameter, press any key within 2 seconds ..  
--------------------------------------------  
[WEB Transmitter(SNS-110) Version 1.1]  
Boot command Loop menu  
--------------------------------------------  
[p] Print Boot Parameters  
[c] Change Boot Parameters  
[q] Quit Menu  
-------------------------------------------  
Select items? [ ] c  
[ WEB Transmitter ( SNS-110 ) Version 1.1 ]  
Boot parameters modification menu  
--------------------------------------------  
[i]. Ip address modify  
[s]. Subnet mask address modify  
[m]. SMTP mail server address modify  
[d]. DNS server address modify  
[g]. Gateway address modify  
[n]. Domain name modify  
[1]. IP auto-regist server address  
[2]. IP auto-regist cgi format  
[3]. IP auto-regist enable/disable  
[4]. IP notify-mail enable/disable  
[5]. IP notify-mail address  
[c]. dhcp flag modify  
[q]. Quit menu  
--------------------------------------------  
Select items? [ ]  
80  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Type "1" and go to IP auto-regist server address" to type registered Web Server address.  
The example below is the IP Address such as 168.219.44,137 or registered host name  
[ WEB Transmitter ( SNS-110 ) Version 1.1 ]  
Boot parameters modification menu  
--------------------------------------------  
[i]. Ip address modify  
.
.
.
.
[q]. Quit menu  
--------------------------------------------  
Select items? [ ] 1  
IP auto-regist server? 168.219.44.147  
Type "2" and go to IP auto-regist cgi format to type the cgi program path to transmit or  
the name of name of the program path, or the transfer factor.  
[ WEB Transmitter ( SNS-110 ) Version 1.1 ]  
Boot parameters modification menu  
--------------------------------------------  
[i]. Ip address modify  
.
.
.
.
[q]. Quit menu  
--------------------------------------------  
Select items? [ ] 2  
IP auto-regist cgi? [/cgi-bin/webtx.cgi?regist=%e&host=%i] /cgi-bin/webtx.cgi?regist=%f&host=%i  
Cgi format to type here are as follows.  
[CGI path] : It is the path of the directory which CGI program is located and it  
has to start with the root symbol (/).  
The example above is /cgi-bin/.  
[CGI program] : It is one of the names of CGI program which server provides.  
The example above is webtx.cgi.  
[Format string] : It is the value that is transmitted as factor to the CGI program.  
If you use the following values starting with %, you can send  
the SNS-110 network information.  
%e : The last three digits of Ethernet address (Hex form)  
Example: ffa142  
%f : The six digits of Ethernet address (Hex form)  
Example: 0000f0ffa142  
81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
%g : Ethernet address (standard) Example: 00-00-f0-ff-a1-42  
%i : IP Address (dotted decimal) Example: 168-219-44-137  
%u : IP Address (32bit unsigned integer, hex form)  
Example: a8db2c89  
%% : Means %  
Select Quit Menu to exit Boot Command Mode.  
[ WEB Transmitter ( SNS-110 ) Version 1.1 ]  
Boot parameters modification menu  
--------------------------------------------  
[i]. Ip address modify  
.
.
.
.
[q]. Quit menu  
--------------------------------------------  
Select items? [ ] q  
--------------------------------------------  
[ WEB Transmitter ( SNS-110 ) Version 1.1 ]  
Boot command Loop menu  
--------------------------------------------  
[p]. Print boot parameters  
[c]. Change boot parameters  
[q]. Quit menu  
-------------------------------------------  
Select items? [ ] q  
New Boot parameter updated.  
.
.
.
If you entered as the example above, the URL that is transmitted to the SNS-110-set  
Administration Server (IP auto-regist server) as follows.  
This means to transmit factors like regist=0000f0ffa142 and host=168.219.44.137 to cgi-  
bin/webtx.cgi of the Administration server which has 168.219.44.147 address. Samsung  
Electronics only provides methods for Ethernet Address and IP aAddress, which transmit  
to the Administration server. Administration Server have to save and manage the  
information (Ethernet Address and IP Address) which it received. Users must deploy  
saving and managing program for this and Samsung Electronics can provide help for  
that.  
82  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting with the Web Browser  
When you have SNS-110 address and can access through the Web Browser, you can  
change the setting as above at the Administrator Mode.  
When you run the Network Setting window as explained in the Chapter 7 and click  
"Advanced" for DHCP, the Dynamic IP setting window appears as below.  
You can change or add the values set at the Console.  
CGI Program for the Administration Server  
examples for setting up the Administration server.  
83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WEB  
E
APPENDIX  
FAQ  
84  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX E FAQ  
As you continue to use SNS-110, there could be some cases, which we have not yet discussed in this  
manual. In such a case, it might actually be when SNS-110 has an error. But in most cases, an easy do-it-  
right can fix the difficulties. Please react to the symptoms by following the instructions below.  
When you get no Message after connected SNS-110 and PC with  
RS-232C Cable and executed Terminal Emulation Program  
(e.g. hyper terminal).  
(1) Refer to "Connecting to RS-232C" of chapter 3, and check the connection condition of RS-232C cable.  
(2) Check whether there is no conflict at the connected PC's COM Port.  
(3) Check if the Terminal Emulation (Hyper Terminal) is running to the PC that you want the connection  
established.  
(4) Check if the settings are correct as is mentioned in "Connecting to RS-232C".  
When inner connections are established but outer ones are not.  
(1) Check if the external user has a proper connection to the Network.  
You can check this by executing "Ping" to the user's IP address at DOS window.  
(2) Access a PC through internal connection, and check if the values are normally set for IP address,  
Gateway, and Subnet Mask of network setup in Administration mode.  
When e-mails are not sent and alarm sets off  
(1) Check and see if the alarm sensor is properly connected to SNS 110, and functions normally.  
(2) Refer to "Connecting to Alarm Sensor", Chapter 3.  
(3) Check the connected values of Alarm/Relay Out setting at Administration mode.  
Take special note for receiver's e-mail address.  
(4) Check the values assigned for Domain Name, SMTP server setting at Administration mode.  
Ex) Domain Name: samsung.co.kr  
SMTP Server : vcr.sec.samsung.co.kr or 168.219.13.12  
(5) Make sure the E-mail address entered on the 'sender' of the Alarm/Relay Out in the Administration Mode  
is valid.  
When there is no response by executing "Ping" in the process of  
setting the IP address  
(1) Check the condition of the network you wish to connect SNS-110 to. Once Network is established,  
LED of SNS-110's Network should be blinking. If it isn't, please contact the network manager.  
85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(2) If LED of Network for SNS-110 is working correctly, the values for Network within SNS-110 might have  
been incorrectly entered. In such a case, refer to Supplement B Factory Default to turn the settings to  
the factory mode. Then, retry setting the IP address again, as shown in Chapter 4.  
The PC to setup the IP Address at SNS-110 must use the IP Address that has the same network as the  
IP Address to setup at SNS-110.  
For example, the IP Address you want to be authorized with SNS-110 is 168.219.15.212, the PC that is  
used for setting up IP Address through arp, ping should be 168.219.15.XX. That means it should have  
the same network class (168.219.15).  
In case the same Network Addresses cannot be authorized, use Hyper Terminal to setup IP Address.  
When connections to SNS-110 cannot be established, after  
connected to Cable Network  
(1) See if the cable modem between cable network and SNS-110 is working correctly.  
Contact the cable modem supplier.  
(2) If it works on Ethernet but does not under cable network mode, re-set the value of network in  
Administration mode to "YES" and disconnect it from Ethernet and install cable network.  
If you try to connect cable network to Ethernet with the value "NO", you cannot obtain an IP address, so  
you will not be able to establish a connection. In such a case, RS-232C's Terminal Emulation (Hyper  
Terminal) should be used in re-setting the value. Refer to Supplement C, How to Use Console.  
(3) If none of the above works, refer to Supplement B to set the values back to the factory mode and install  
Cable Network.  
If you wish to check the IP Address under auto-set IP address  
environment  
(1) Under the network condition of DHCP server using Cable Network or Ethernet, install SNS 110 and turn  
the SNS-110 power on, then you will be given with an IP address from DHCP Server. This will auto-set  
the information for SNS-110's network information.  
(2) Set the SNS-110 and peripheral PC's RS-232C cable to SNS-110's IP address, then refer to  
Supplement C How to Use Console to check the network information.  
(3) Note that a new IP addresses will be given every time you turn the power on for SNS-110 under auto-set  
IP Address.  
(4) If you wish to receive a fixed IP address under the auto-set IP address environment through Ethernet,  
you may contact the manager and have an IP address fixed to your connection by registering your IP  
address and Ethernet address.  
(5) When you connected SNS-110 with Cable Modem, it’s easy to manage the assigned IP Address if you  
use the method using Administration server explained earlier.  
86  
Download from Www.Somanuals.com. All Manuals Search And Download.  
When the post-version software still operates, even after you have  
installed the updated version.  
(1) When you upgrade to the latest version of the software, the "Uploading is successful! New code will  
be loaded after reset" message appears. When this message appears, reset or restart SNS-110 and  
the new software will reboot the system.  
(2)To check the version, press "about" in "Administrator Mode" in SNS-110.  
When normally-functioning SNS-110 is suddenly not  
connecting  
(1) Check if the LED light is blinking on the front of SNS-110.  
(2) If it isn't, contact the network manager to check the status of network. If no fault is identified from the  
network, refer to Supplement B, Factory Default, and set the information back to its original status,  
and Use chapter 4 to set an IP address.  
(3) If the system does not work even after a new IP Address has been selected, contact your local  
service center.  
When SNS-110 does not work after downloading to upgrade to the  
latest version of the S/W of SNS-110  
(1) If you upgraded SNS-110 by using a separate file other than one was supplied by Samsung  
Electronics, it becomes non-functional.  
(2) If your SNS-110 doesn't function at all, even though the software normally supplied by Samsung  
Electronics was used for upgrading., then contact your vendor or Service Center.  
87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If the Video image has problems when connected to SNS-110 using  
a Netscape  
(1) This can happen if Netscape 6.0 or above is used.  
(2) Use Netscape 5.X or below.  
(3) The defects related to Netscape 6.0 are being fixed.  
You cannot use FTP for transfer when setting up FTP transfer  
(1) Check [Start] – [Settings] to see if current time is set for SNS-110. If the current time is not properly  
set, FTP transfer does not work.  
(2) Check "File Transfer setting menu" to see if each camera setting is set "Both" or "Once." or "Every" .  
(If it is set "none," it doesn’t work.)  
(3) Check "Every" item in "File Transfer Setting menu" to see if proper values are set.  
(4) Check "Between" item in "File Transfer Setting menu" to see if proper values are set. "All day mode"  
can be set as "0:0:0 ~ 0:0:0."  
(5) Check "Day" item in "File Transfer Setting menu" to see if proper values are set. Click "Every day" for  
"Every day mode."  
(6) Check "Network Setting Menu" to see if FTP Srerver "IP Address" , "FTP Port" and "User" ,  
"Password" , "Directory" is properly set.  
(7) Check “FTP Server” is properly set.  
(8) Check “FTP Server” connected to “user” is properly set.  
If none of the above helps for troubleshooting, please contact the dealer, or  
contact SNS-110's service center, in which you will receive professional  
assistance.  
88  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRONICS  
AB68-00278A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

RCA MP3 Player M45 series User Guide
Remington Hair Dryer DC 1880 User Guide
Rival Slow Cooker 3122 CH User Guide
Rosewill Car Video System R500N User Guide
Runco Projector VX 1000CI User Guide
Samsung Home Theater System 20051111103302296 User Guide
Sanyo Headphones SHE9503 User Guide
Sanyo Microwave Oven EM S3579V User Guide
Sapphire Audio Computer Hardware ML00042 R5 User Guide
Savin All in One Printer 2235 User Guide