Washer
PRODUCT MODEL NUMBERS
RECESSED AREA OR CLOSET INSTALLATION
RTW4100S
RTW4305V
If a closet door is installed, the minimum ventilation openings in the top and bottom of
the door are required (view 3). Louvered doors with equivalent air ventilation openings in
the top and bottom are acceptable.
"
Electrical: A 120-volt, 60-Hz, AC-only,
"
15- or 20-amp, fused electrical supply is required.
A time-delay fuse or circuit breaker is
"
"
recommended. It is recommended that a separate
circuit serving only this appliance be provided.
"
"
"
"
"
"
"
"
1
2
3
Front view
Side view
Closet door with vents
DRAIN SYSTEM OPTIONS
Standpipe drain system - wall or floor (view 1 & 2)
The standpipe drain requires a minimum diameter standpipe of
2" (5 cm). The minimum carry-away capacity can be no less
than 17 gal. (64 L) per minute.
The top of the standpipe must be at least 39" (99 cm) high and
no higher than 96" (244 cm) from the bottom of the washer.
Laundry tub drain system (view 3)
The laundry tub needs a minimum
20 gal. (76 L) capacity. The top of the
laundry tub must be at least 39"
(99 cm) above the floor and no higher
than 96" (244 cm) from the bottom of
the washer.
Floor drain system (view 4)
The floor drain system requires a siphon
break that may be purchased separately.
The siphon break must be a minimum of
28" (71 cm) from the bottom of the
washer. Additional hoses might be
needed.
IMPORTANT: To avoid siphoning, no more than 8" (20.3 cm)
of drain hose should be inside the standpipe.
39"
(99 cm)
28"
(71 cm)
39"
(99 cm)
3
4
1
2
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10200331B
10-22-08