					Electric Dryer   
					PRODUCT MODEL NUMBERS   
					OVERALL DIMENSIONS   
					DOOR CLEARANCE DIMENSIONS   
					3-7/8"   
					RES7646J   
					RES7646K   
					RES7648E   
					RES7648J   
					RES7648K   
					REX3614J   
					REX3614K   
					REX3615E   
					REX4625E   
					REX4634J   
					REX4634K   
					REX4635E   
					REX5634J   
					REX5634K   
					REX5635E   
					22-3/4"   
					terminal   
					block cover   
					19-1/8"   
					power supply   
					cord/cable   
					opening   
					22-3/4"   
					Super-large   
					14-1/2"   
					side-swing door (reversible)   
					42-3/8"*   
					Electrical: A four-wire or three-wire, single phase,   
					120/240-volt, 60-Hz, AC-only, electrical supply is   
					required on a separate 30-ampere circuit, fused on   
					both sides of the line. Use 10 gauge solid copper   
					wire. A time-delay fuse or circuit breaker is   
					recommended.   
					Exhaust venting: Exhaust your dryer to the   
					outside. Four-inch diameter vent is required. Rigid   
					or flexible metal exhaust vent must be used. Do Not   
					use plastic or metal foil vent. Exhaust outlet hood   
					must be at least 12 inches from the ground or any   
					object that may be in the path of the exhaust.   
					7"   
					6"*   
					22-3/4"   
					dryer exhaust   
					vent   
					17-3/4"   
					28" max.   
					29"   
					22-3/4"   
					*from floor with dryer   
					feet extended 1 inch   
					Large side-swing   
					door (reversible)   
					8-1/4"   
					15-1/4"   
					RECESSED AREA AND CLOSET INSTALLATION   
					Recommended/Minimum   
					Closet confined area   
					Back Sides   
					5"/0" 1"/0"   
					5"/4" 1"/0"   
					Top   
					18"/18"   
					Front   
					— 
					18"/18" 1"/1"   
					If a closet door is installed: The minimum unobstructed air   
					openings are required. Louvered doors with equivalent air   
					openings are acceptable.   
					Recessed   
					Closet   
					15-1/4"   
					front view   
					front view   
					side view   
					3"   
					15-1/4"   
					Small side-swing door   
					14"   
					48 sq. in.**   
					max.   
					closet   
					door   
					8-3/4"   
					25-5/8"   
					Recessed   
					area   
					18"   
					4"***   
					24 sq. in.**   
					13-3/4"   
					3"   
					1"   
					0" *   
					0" *   
					13-3/4"   
					Extra-large hamper door   
					** Minimum top and bottom air openings for closet door.   
					*** External exhaust elbow requires additional space.   
					*Wall, door and floor molding may require   
					additional spacing.   
					EXHAUST VENTING   
					Preferred   
					Acceptable   
					Select the route that will provide the straightest and most direct path   
					outdoors. Plan the installation to use the fewest number of elbows and   
					turns. Avoid making 90° turns.   
					When using elbows or making turns, allow as much room as possible.   
					Bend flexible metal vent gradually to avoid kinking.   
					4"   
					4"   
					2-1/2"   
					Determine vent length   
					When you have a 4" hood   
					When you have a 2-1/2" hood   
					1. See the exhaust vent length chart that matches your type hood for the   
					maximum vent lengths you can use.   
					Maximum length of 4"   
					diameter metal vent   
					Maximum length of 4"   
					diameter metal vent   
					Do not use vent runs longer than specified in exhaust vent length charts.   
					2. Determine the number of elbows you will need.   
					3. In the column listing the type of metal vent you are using (rigid or   
					flexible), find the maximum length of metal vent on the same line as the   
					number of elbows.   
					Number of   
					90° elbows   
					Rigid   
					Flexible   
					Number of   
					90° elbows   
					Rigid   
					Flexible   
					(fully extended)   
					(fully extended)   
					0 
					1 
					2 
					3 
					4 
					64 ft.   
					54 ft.   
					44 ft.   
					35 ft.   
					27 ft.   
					36 ft.   
					31 ft.   
					27 ft.   
					25 ft.   
					23 ft.   
					0 
					1 
					2 
					3 
					4 
					58 ft.   
					48 ft.   
					38 ft.   
					29 ft.   
					21 ft.   
					28 ft.   
					23 ft.   
					19 ft.   
					17 ft.   
					15 ft.   
					The maximum length using a 2" x 6" rectangular vent with 2 elbows and   
					a 2-1/2" exhaust hood is 8 ft.   
					Because Whirlpool Corporation policy includes a continuous commitment to improve   
					our products, we reserve the right to change materials and specifications without notice.   
					Dimensions are for planning purposes only. For complete details, see Installation   
					Instructions packed with product. Specifications subject to change without notice.   
					Ref. 3397618   
					01-09-03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |