PACKAGE HEAT PUMP UNITS
FORM NO. P11-763 REV. 1
Supersedes Form No. P11-763
RJNA- HIGH EFFICIENCY SERIES
NOMINAL SIZES 3-5 TONS [10.6-17.6 kW]
*Unit shown with
optional louver
panels installed.
ISO 9001:2000
“CERTIFIED UNDER THE
A.R.I. CERTIFICATION
PROGRAM—A.R.I.
STANDARD 240”
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
These quality features are included in the Rheem
Outdoor Package Heat Pumps
Control Box Access
Compressor Access
Blower Access
Optional Electric Heater Kit
Evaporator Coil/Filter Access
3
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
ENGINEERING FEATURES
RJNA- Series Package Heat Pumps
1. All models feature Copeland® Scroll® compressors offering maximum reliability, efficiency, and quiet
operation.
2. One-piece top over the indoor section with drip lip, drawn painted base pan, and 1" [25.4 mm] raised flanges
for supply/return air connections provides superior water management.
3. Convertible horizontal and vertical airflow design allows maximum field flexibility and minimizes inventory
requirements.
4. Standard full perimeter forkable baserail with lifting holes for easier maneuvering and installations.
5. Factory installed one-inch [25.4 mm] throw away filter with provisions for two-inch [50.8 mm] filter.
6. Direct or belt drive options to accommodate a wide range of design conditions as high as 1.5 inches
[37 kPa] of external static pressure.
7. Easily removable filter, blower, electric heat, and compressor/control access panels permits prompt service.
8. Number and color coded wiring helps facilitate service and maintenance.
9. Common cabinet and components allows for installation flexibility and fewer parts to inventory.
10. Standard high pressure control on all models.
11. Externally mounted refrigerant gauge ports for easy service diagnostics.
12. Side and base electric power entry helps minimize roof penetrations.
13. Quick assembly common roof curbs helps save field labor and maximize size flexibility.
14. Factory or field installed electric heat kits available up to 24 KW.
15. Easy to install plug-in, slip-in economizers; 100% fully modulating, single enthalpy.
16. Quality powder paint finish offers long lasting protection against extreme weather conditions and is able to
withstand 1000 HR salt spray test.
[
] Designates Metric Conversions
4
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL IDENTIFICATION—RJNA- SERIES
R J N A — A 036 J K 000
Electric Heat
000 = No Resistance Heat
010 = 10 kW Resistance Heat
015 = 15 kW Resistance Heat
020 = 20 kW Resistance Heat
Drive Package
K = Direct Drive
L = Belt Drive
M = Belt Drive—High Static
Electrical Designation
J = 208-230 V, 1 PH, 60 Hz
C = 208-230 V, 3 PH, 60 Hz
D = 460 V, 3 PH, 60 Hz
Nominal Cooling Capacity
(BTUH) [kW]
036 = 36,000 [10.55]
042 = 42,000 [12.31]
048 = 48,000 [14.07]
060 = 60,000 [17.58]
Future Technical Variations
Design Series
A = 1st Design
Efficiency Designation
N = 13 SEER
Product Classification
J = Package Heat Pump—
Light Commercial
Tradebrand
R = Rheem
[
] Designates Metric Conversions
5
Download from Www.Somanuals.com. All Manuals Search And Download.
OPTIONS—RJNA- SERIES
FACTORY INSTALLED OPTION CODES FOR RJNA (3-5 Ton) [10.6-17.6 kW]
(A036, A042, A048, A060)
Low Ambient
Time Delay
Freeze Stat
Reduced Height
Baserails
Option Code
Hail Guard
Side Flow
AA
AD
AF
No Options
x
x
x
x
AK
AL
BD
BS
BX
CK
x
x
x
x
x
x
x
x
x
Example: RJNA-A060CK000XXX (where XX is factory installed option)
Example: No Options
RJNA-A060CK000
Example: No Options with Factory Installed Economizer
RJNA-A060CK000AAB
Example: Options with Hail Guard, Low Ambient, Time Delay and Freeze Stat with No Factory Installed Economizer
RJNA-A060CK000BDA
Example: Options same as above with Factory Installed Economizer
RJNA-A060CK000BDB
ECONOMIZER SELECTION FOR RJNA-
Single Enthalpy Economizer
With Barometric Relief
No Economizer
A
B
x
x
“x” indicates factory installed option.
[
] Designates Metric Conversions
6
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL DATA—RJNA- SERIES
NOMINAL SIZES 3-5 TONS [10.6-17.6 kW]
Model RJNA- Series
Cooling Performance1
Gross Cooling Capacity Btu [kW]
EER/SEER2
A036CK
A036CL
A036CM
A036DK
CONTINUED
37,600 [11]
11.6/13
37,600 [11]
11.6/13
37,600 [11]
11.6/13
37,600 [11]
11.6/13
Nominal CFM/ARI Rated CFM [L/s]
ARI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
Heating Performance (Heat Pumps)
Heating Temp. Btuh [kW] Rating
System Power KW/COP
Low Temp. Btuh [kW] Rating
System Power KW/COP
HSPF (Btu/Watts-hr)
Compressor
1200/1200 [566/566]
36,000 [10.5]
26,823 [7.9]
9177 [2.7]
1200/1200 [566/566]
36,000 [10.5]
26,823 [7.9]
9177 [2.7]
1200/1200 [566/566]
36,000 [10.5]
26,823 [7.9]
9177 [2.7]
1200/1200 [566/566]
36,000 [10.5]
26,823 [7.9]
9177 [2.7]
3.1
3.1
3.1
3.1
35,600 [10.4]
3.2/3.3
35,600 [10.4]
3.2/3.3
35,600 [10.4]
3.2/3.3
35,600 [10.4]
3.2/3.3
21,200 [6.2]
3/2.08
21,200 [6.2]
3/2.08
21,200 [6.2]
3/2.08
21,200 [6.2]
3/2.08
7.7
7.7
7.7
7.7
No./Type
1/Copeland Scroll
83
1/Copeland Scroll
83
1/Copeland Scroll
83
1/Copeland Scroll
83
Outdoor Sound Rating (dB)3
Outdoor Coil—Fin Type
Tube Type
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
Refrigerant Control
Indoor Coil—Fin Type
Tube Type
Tube Size in. [mm]
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
Outdoor Fan—Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
No. Motors/HP
Motor RPM
Indoor Fan—Type
FC Centrifugal
1/10x10 [254x254]
Direct/3
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
FC Centrifugal
1/10x10 [254x254]
Direct/3
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
No. Motors
1
1
Motor HP
1/2
1/2
3/4
1/2
Motor RPM
1075
1725
1725
1075
Motor Frame Size
48
56
56
48
Filter—Type
Disposable
Yes
Disposable
Yes
Disposable
Yes
Disposable
Yes
Furnished
(No.) Size Recommended in. [mm]
Refrigerant Charge Oz. [g]
Weights
(2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406]
182 [5160]
182 [5160]
182 [5160]
182 [5160]
Net Weight lbs. [kg]
Ship Weight lbs. [kg]
See Page 14 for Notes.
517 [235]
532 [241]
517 [235]
532 [241]
517 [235]
532 [241]
517 [235]
532 [241]
[
] Designates Metric Conversions
7
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL DATA—RJNA- SERIES
NOMINAL SIZES 3-5 TONS [10.6-17.6 kW]
Model RJNA- Series
Cooling Performance1
Gross Cooling Capacity Btu [kW]
EER/SEER2
A036DL
A036DM
A036JK
A042CK
CONTINUED
42,500 [12.5]
11.8/13
37,600 [11]
11.6/13
37,600 [11]
11.6/13
37,600 [11]
11.6/13
Nominal CFM/ARI Rated CFM [L/s]
ARI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
Heating Performance (Heat Pumps)
Heating Temp. Btuh [kW] Rating
System Power KW/COP
Low Temp. Btuh [kW] Rating
System Power KW/COP
HSPF (Btu/Watts-hr)
Compressor
1200/1200 [566/566]
36,000 [10.5]
26,823 [7.9]
9177 [2.7]
1200/1200 [566/566]
36,000 [10.5]
26,823 [7.9]
9177 [2.7]
1200/1200 [566/566]
36,000 [10.5]
26,823 [7.9]
9177 [2.7]
1400/1400 [661/661]
40,500 [11.9]
30,124 [8.8]
10,376 [3]
3.1
3.1
3.1
3.4
35,600 [10.4]
3.2/3.3
35,600 [10.4]
3.2/3.3
35,600 [10.4]
3.2/3.3
40,000 [11.7]
3.6/3.28
21,200 [6.2]
3/2.08
21,200 [6.2]
3/2.08
21,200 [6.2]
3/2.08
23,200 [6.8]
3.3/2.06
7.7
7.7
7.7
7.7
No./Type
1/Copeland Scroll
83
1/Copeland Scroll
83
1/Copeland Scroll
83
1/Copeland Scroll
83
Outdoor Sound Rating (dB)3
Outdoor Coil—Fin Type
Tube Type
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
Refrigerant Control
Indoor Coil—Fin Type
Tube Type
Tube Size in. [mm]
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
Outdoor Fan—Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
No. Motors/HP
Motor RPM
Indoor Fan—Type
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
FC Centrifugal
1/10x10 [254x254]
Direct/3
FC Centrifugal
1/10x10 [254x254]
Direct/3
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
No. Motors
1
1
Motor HP
1/2
3/4
1/2
1/2
Motor RPM
1725
1725
1075
1075
Motor Frame Size
56
56
48
48
Filter—Type
Disposable
Yes
Disposable
Yes
Disposable
Yes
Disposable
Yes
Furnished
(No.) Size Recommended in. [mm]
Refrigerant Charge Oz. [g]
Weights
(2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406]
182 [5160]
182 [5160]
182 [5160]
177 [5018]
Net Weight lbs. [kg]
Ship Weight lbs. [kg]
See Page 14 for Notes.
517 [235]
532 [241]
517 [235]
532 [241]
517 [235]
532 [241]
521 [236]
536 [243]
[
] Designates Metric Conversions
8
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL DATA—RJNA- SERIES
NOMINAL SIZES 3-5 TONS [10.6-17.6 kW]
Model RJNA- Series
Cooling Performance1
Gross Cooling Capacity Btu [kW]
EER/SEER2
A042CL
A042CM
A042DK
A042DL
CONTINUED
42,500 [12.5]
11.8/13
42,500 [12.5]
11.8/13
42,500 [12.5]
11.8/13
42,500 [12.5]
11.8/13
Nominal CFM/ARI Rated CFM [L/s]
ARI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
Heating Performance (Heat Pumps)
Heating Temp. Btuh [kW] Rating
System Power KW/COP
Low Temp. Btuh [kW] Rating
System Power KW/COP
HSPF (Btu/Watts-hr)
Compressor
1400/1400 [661/661]
40,500 [11.9]
30,124 [8.8]
10,376 [3]
1400/1400 [661/661]
40,500 [11.9]
30,124 [8.8]
10,376 [3]
1400/1400 [661/661]
40,500 [11.9]
30,124 [8.8]
10,376 [3]
1400/1400 [661/661]
40,500 [11.9]
30,124 [8.8]
10,376 [3]
3.4
3.4
3.4
3.4
40,000 [11.7]
3.6/3.28
40,000 [11.7]
3.6/3.28
40,000 [11.7]
3.6/3.28
40,000 [11.7]
3.6/3.28
23,200 [6.8]
3.3/2.06
23,200 [6.8]
3.3/2.06
23,200 [6.8]
3.3/2.06
23,200 [6.8]
3.3/2.06
7.7
7.7
7.7
7.7
No./Type
1/Copeland Scroll
83
1/Copeland Scroll
83
1/Copeland Scroll
83
1/Copeland Scroll
83
Outdoor Sound Rating (dB)3
Outdoor Coil—Fin Type
Tube Type
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
Refrigerant Control
Indoor Coil—Fin Type
Tube Type
Tube Size in. [mm]
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
Outdoor Fan—Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
No. Motors/HP
Motor RPM
Indoor Fan—Type
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
FC Centrifugal
1/10x10 [254x254]
Direct/3
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
No. Motors
1
Motor HP
1/2
3/4
1/2
1/2
Motor RPM
1725
1725
1075
1725
Motor Frame Size
56
56
48
56
Filter—Type
Disposable
Yes
Disposable
Yes
Disposable
Yes
Disposable
Yes
Furnished
(No.) Size Recommended in. [mm]
Refrigerant Charge Oz. [g]
Weights
(2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406]
177 [5018]
177 [5018]
177 [5018]
177 [5018]
Net Weight lbs. [kg]
Ship Weight lbs. [kg]
See Page 14 for Notes.
521 [236]
536 [243]
521 [236]
536 [243]
521 [236]
536 [243]
521 [236]
536 [243]
[
] Designates Metric Conversions
9
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL DATA—RJNA- SERIES
NOMINAL SIZES 3-5 TONS [10.6-17.6 kW]
Model RJNA- Series
Cooling Performance1
Gross Cooling Capacity Btu [kW]
EER/SEER2
A042DM
A042JK
A048CK
A048CL
CONTINUED
49,500 [14.5]
11.65/13
42,500 [12.5]
11.8/13
42,500 [12.5]
11.8/13
49,500 [14.5]
11.65/13
Nominal CFM/ARI Rated CFM [L/s]
ARI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
Heating Performance (Heat Pumps)
Heating Temp. Btuh [kW] Rating
System Power KW/COP
Low Temp. Btuh [kW] Rating
System Power KW/COP
HSPF (Btu/Watts-hr)
Compressor
1400/1400 [661/661]
40,500 [11.9]
30,124 [8.8]
10,376 [3]
1400/1400 [661/661]
40,500 [11.9]
30,124 [8.8]
10,376 [3]
1600/1600 [755/755]
47,000 [13.8]
34,700 [10.2]
12,300 [3.6]
4
1600/1600 [755/755]
47,000 [13.8]
34,700 [10.2]
12,300 [3.6]
4
3.4
3.4
40,000 [11.7]
3.6/3.28
40,000 [11.7]
3.6/3.28
46,500 [13.6]
3.9/3.5
46,500 [13.6]
3.9/3.5
23,200 [6.8]
3.3/2.06
23,200 [6.8]
3.3/2.06
27,800 [8.1]
3.7/2.22
7.7
27,800 [8.1]
3.7/2.22
7.7
7.7
7.7
No./Type
1/Copeland Scroll
83
1/Copeland Scroll
83
1/Copeland Scroll
83
1/Copeland Scroll
83
Outdoor Sound Rating (dB)3
Outdoor Coil—Fin Type
Tube Type
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
Refrigerant Control
Indoor Coil—Fin Type
Tube Type
Tube Size in. [mm]
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
Outdoor Fan—Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
No. Motors/HP
Motor RPM
Indoor Fan—Type
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
FC Centrifugal
1/10x10 [254x254]
Direct/3
FC Centrifugal
1/10x10 [254x254]
Direct/3
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
No. Motors
1
1
Motor HP
3/4
1/2
1/2
1/2
Motor RPM
1725
1075
1075
1725
Motor Frame Size
56
48
48
56
Filter—Type
Disposable
Yes
Disposable
Yes
Disposable
Yes
Disposable
Yes
Furnished
(No.) Size Recommended in. [mm]
Refrigerant Charge Oz. [g]
Weights
(2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406]
177 [5018]
177 [5018]
206 [5840]
206 [5840]
Net Weight lbs. [kg]
Ship Weight lbs. [kg]
See Page 14 for Notes.
521 [236]
536 [243]
521 [236]
536 [243]
535 [243]
550 [249]
535 [243]
550 [249]
[
] Designates Metric Conversions
10
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL DATA—RJNA- SERIES
NOMINAL SIZES 3-5 TONS [10.6-17.6 kW]
Model RJNA- Series
Cooling Performance1
Gross Cooling Capacity Btu [kW]
EER/SEER2
A048CM
A048DK
A048DL
A048DM
CONTINUED
49,500 [14.5]
11.65/13
49,500 [14.5]
11.65/13
49,500 [14.5]
11.65/13
49,500 [14.5]
11.65/13
Nominal CFM/ARI Rated CFM [L/s]
ARI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
Heating Performance (Heat Pumps)
Heating Temp. Btuh [kW] Rating
System Power KW/COP
Low Temp. Btuh [kW] Rating
System Power KW/COP
HSPF (Btu/Watts-hr)
Compressor
1600/1600 [755/755]
47,000 [13.8]
34,700 [10.2]
12,300 [3.6]
4
1600/1600 [755/755]
47,000 [13.8]
34,700 [10.2]
12,300 [3.6]
4
1600/1600 [755/755]
47,000 [13.8]
34,700 [10.2]
12,300 [3.6]
4
1600/1600 [755/755]
47,000 [13.8]
34,700 [10.2]
12,300 [3.6]
4
46,500 [13.6]
3.9/3.5
46,500 [13.6]
3.9/3.5
46,500 [13.6]
3.9/3.5
46,500 [13.6]
3.9/3.5
27,800 [8.1]
3.7/2.22
7.7
27,800 [8.1]
3.7/2.22
7.7
27,800 [8.1]
3.7/2.22
7.7
27,800 [8.1]
3.7/2.22
7.7
No./Type
1/Copeland Scroll
83
1/Copeland Scroll
83
1/Copeland Scroll
83
1/Copeland Scroll
83
Outdoor Sound Rating (dB)3
Outdoor Coil—Fin Type
Tube Type
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
Refrigerant Control
Indoor Coil—Fin Type
Tube Type
Tube Size in. [mm]
0.375 [9.5]
5.16 [0.48]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
Outdoor Fan—Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
No. Motors/HP
Motor RPM
Indoor Fan—Type
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
FC Centrifugal
1/10x10 [254x254]
Direct/3
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
No. Motors
1
Motor HP
3/4
1/2
1/2
3/4
Motor RPM
1725
1075
1725
1725
Motor Frame Size
56
48
56
56
Filter—Type
Disposable
Yes
Disposable
Yes
Disposable
Yes
Disposable
Yes
Furnished
(No.) Size Recommended in. [mm]
Refrigerant Charge Oz. [g]
Weights
(2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406]
206 [5840]
206 [5840]
206 [5840]
206 [5840]
Net Weight lbs. [kg]
Ship Weight lbs. [kg]
See Page 14 for Notes.
535 [243]
550 [249]
535 [243]
550 [249]
535 [243]
550 [249]
535 [243]
550 [249]
[
] Designates Metric Conversions
11
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL DATA—RJNA- SERIES
NOMINAL SIZES 3-5 TONS [10.6-17.6 kW]
Model RJNA- Series
Cooling Performance1
Gross Cooling Capacity Btu [kW]
EER/SEER2
A048JK
A060CK
A060CL
A060CM
CONTINUED
64,000 [18.8]
11.55/13
49,500 [14.5]
11.65/13
63,500 [18.6]
11.55/13
64,000 [18.8]
11.55/13
Nominal CFM/ARI Rated CFM [L/s]
ARI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
Heating Performance (Heat Pumps)
Heating Temp. Btuh [kW] Rating
System Power KW/COP
Low Temp. Btuh [kW] Rating
System Power KW/COP
HSPF (Btu/Watts-hr)
Compressor
1600/1600 [755/755]
47,000 [13.8]
34,700 [10.2]
12,300 [3.6]
4
2000/2000 [944/944]
61,500 [18]
43,800 [12.8]
17,700 [5.2]
5.3
2000/2000 [944/944]
61,500 [18]
43,800 [12.8]
17,700 [5.2]
5.3
2000/2000 [944/944]
61,500 [18]
43,800 [12.8]
17,700 [5.2]
5.3
46,500 [13.6]
3.9/3.5
60,500 [17.7]
5/3.5
60,500 [17.7]
5/3.5
60,500 [17.7]
5/3.5
27,800 [8.1]
3.7/2.22
7.7
36,000 [10.5]
4.4/2.3
36,000 [10.5]
4.4/2.3
36,000 [10.5]
4.4/2.3
7.7
7.7
7.7
No./Type
1/Copeland Scroll
83
1/Copeland Scroll
83
1/Copeland Scroll
83
1/Copeland Scroll
83
Outdoor Sound Rating (dB)3
Outdoor Coil—Fin Type
Tube Type
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
Refrigerant Control
Indoor Coil—Fin Type
Tube Type
Tube Size in. [mm]
0.375 [9.5]
5.16 [0.48]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
Outdoor Fan—Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
No. Motors/HP
Motor RPM
Indoor Fan—Type
FC Centrifugal
1/10x10 [254x254]
Direct/3
FC Centrifugal
1/11x9 [279.4x228.6]
Direct/2
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
No. Motors
1
1
Motor HP
1/2
1
3/4
1
Motor RPM
1075
1100
1725
1725
Motor Frame Size
48
48
56
56
Filter—Type
Disposable
Yes
Disposable
Yes
Disposable
Yes
Disposable
Yes
Furnished
(No.) Size Recommended in. [mm]
Refrigerant Charge Oz. [g]
Weights
(2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406]
206 [5840]
184 [5216]
184 [5216]
184 [5216]
Net Weight lbs. [kg]
535 [243]
550 [249]
565 [256]
580 [263]
565 [256]
580 [263]
565 [256]
580 [263]
Ship Weight lbs. [kg]
See Page 14 for Notes.
[
] Designates Metric Conversions
12
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL DATA—RJNA- SERIES
NOMINAL SIZES 3-5 TONS [10.6-17.6 kW]
Model RJNA- Series
Cooling Performance1
Gross Cooling Capacity Btu [kW]
EER/SEER2
A060DL
A060DM
A060JK
64,000 [18.8]
11.55/13
64,000 [18.8]
11.55/13
63,500 [18.6]
11.55/13
Nominal CFM/ARI Rated CFM [L/s]
ARI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
Heating Performance (Heat Pumps)
Heating Temp. Btuh [kW] Rating
System Power KW/COP
Low Temp. Btuh [kW] Rating
System Power KW/COP
HSPF (Btu/Watts-hr)
Compressor
2000/2000 [944/944]
61,500 [18]
43,800 [12.8]
17,700 [5.2]
5.3
2000/2000 [944/944]
61,500 [18]
43,800 [12.8]
17,700 [5.2]
5.3
2000/2000 [944/944]
61,500 [18]
43,800 [12.8]
17,700 [5.2]
5.3
60,500 [17.7]
5/3.5
60,500 [17.7]
5/3.5
60,500 [17.7]
5/3.5
36,000 [10.5]
4.4/2.3
36,000 [10.5]
4.4/2.3
36,000 [10.5]
4.4/2.3
7.7
7.7
7.7
No./Type
1/Copeland Scroll
83
1/Copeland Scroll
83
1/Copeland Scroll
83
Outdoor Sound Rating (dB)3
Outdoor Coil—Fin Type
Tube Type
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
16.56 [1.54]
2 / 22 [9]
TX Valves
Louvered
Rifled
Refrigerant Control
Indoor Coil—Fin Type
Tube Type
Tube Size in. [mm]
0.375 [9.5]
5.16 [0.48]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
0.375 [9.5]
5.16 [0.48]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
Outdoor Fan—Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
4000 [1888]
1 at 1/3 HP
1075
No. Motors/HP
Motor RPM
Indoor Fan—Type
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
FC Centrifugal
1/10x10 [254x254]
Belt/Variable
1
FC Centrifugal
1/11x9 [279.4x228.6]
Direct/2
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
No. Motors
1
Motor HP
3/4
1
1
Motor RPM
1725
1725
1100
Motor Frame Size
56
56
48
Filter—Type
Disposable
Yes
Disposable
Yes
Disposable
Yes
Furnished
(No.) Size Recommended in. [mm]
Refrigerant Charge Oz. [g]
Weights
(2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406] (2)1x25x16 [25x635x406]
184 [5216]
184 [5216]
184 [5216]
Net Weight lbs. [kg]
Ship Weight lbs. [kg]
See Page 14 for Notes.
565 [256]
580 [263]
565 [256]
580 [263]
565 [256]
580 [263]
[
] Designates Metric Conversions
13
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL DATA—RJNA- SERIES
NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not
include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for
operation to Ϯ20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment
certification program, which is based on ARI Standard 210/240 or 360.
2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270.
[
] Designates Metric Conversions
14
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEMS PERFORMANCE—RJNA- SERIES
COOLING PERFORMANCE DATA—RJNA-A036
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE
CFM [L/s]
DR ➀
71°F [21.7°C]
1200 [566]
.13
67°F [19.4°C]
1200 [566]
.13
63°F [17.2°C]
1200 [566]
.13
1440 [680]
.16
960 [453]
.08
1440 [680]
.16
960 [453]
.08
1440 [680]
.16
960 [453]
.08
Total BTUH [kW] 46.4 [13.60] 44.8 [13.13] 43.1 [12.63] 43.4 [12.72] 41.9 [12.28] 40.4 [11.84] 41.1 [12.05] 39.7 [11.63] 38.2 [11.20]
75
[23.9]
Sens BTUH [kW] 27.9 [8.18] 25.5 [7.47] 23.1 [6.77] 33.5 [9.82] 30.6 [8.97] 27.7 [8.12] 34.8 [10.20] 31.8 [9.32] 28.8 [8.44]
Power
2.2
2.2
2.2
2.2
2.2
2.1
2.2
2.2
2.1
O
U
T
D
O
O
R
Total BTUH [kW] 45.5 [13.33] 43.9 [12.87] 42.3 [12.40] 42.6 [12.48] 41.1 [12.05] 39.6 [11.61] 40.2 [11.78] 38.8 [11.37] 37.4 [10.96]
80
Sens BTUH [kW] 27.3 [8.00] 25.0 [7.33] 22.6 [6.62] 32.9 [9.64] 30.0 [8.79] 27.2 [7.97] 34.2 [10.02] 31.3 [9.17] 28.3 [8.29]
[26.7]
Power
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
Total BTUH [kW] 44.5 [13.04] 42.9 [12.57] 41.3 [12.10] 41.5 [12.16] 40.0 [11.72] 38.6 [11.31] 39.2 [11.49] 37.8 [11.08] 36.4 [10.67]
85
[29.4]
Sens BTUH [kW] 26.7 [7.83] 24.4 [7.15] 22.1 [6.48] 32.3 [9.47] 29.5 [8.65] 26.8 [7.85] 33.6 [9.85] 30.7 [9.00] 27.9 [8.18]
Power
2.5
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
D
R
Y
Total BTUH [kW] 43.3 [12.69] 41.7 [12.22] 40.2 [11.78] 40.3 [11.81] 38.9 [11.40] 37.5 [10.99] 38.0 [11.14] 36.6 [10.73] 35.3 [10.35]
90
[32.2]
Sens BTUH [kW] 26.1 [7.65] 23.9 [7.00] 21.7 [6.36] 31.7 [9.29] 29.0 [8.50] 26.3 [7.71] 33.0 [9.67] 30.2 [8.85] 27.4 [8.03]
B
U
L
Power
2.6
2.5
2.5
2.6
2.5
2.5
2.6
2.5
2.5
Total BTUH [kW] 42.0 [12.31] 40.5 [11.87] 39.0 [11.43] 39.0 [11.43] 37.6 [11.02] 36.3 [10.64] 36.7 [10.76] 35.4 [10.37] 34.1 [9.99]
95
[35]
B
Sens BTUH [kW] 25.6 [7.50] 23.4 [6.86] 21.2 [6.21] 31.1 [9.11] 28.5 [8.35] 25.8 [7.56] 32.4 [9.50] 29.7 [8.70] 26.9 [7.88]
Power
2.7
2.6
2.6
2.7
2.6
2.6
2.7
2.6
2.6
T
E
M
P
E
R
A
T
Total BTUH [kW] 40.7 [11.93] 39.3 [11.52] 37.8 [11.08] 37.7 [11.05] 36.4 [10.67] 35.1 [10.29] 35.4 [10.37] 34.2 [10.02] 32.9 [9.64]
100
[37.8]
Sens BTUH [kW] 25.0 [7.33] 22.8 [6.68] 20.7 [6.07] 30.5 [8.94] 27.9 [8.18] 25.3 [7.41] 31.9 [9.35] 29.1 [8.53] 26.4 [7.74]
Power
2.8
2.8
2.7
2.8
2.7
2.7
2.8
2.7
2.7
Total BTUH [kW] 39.5 [11.58] 38.1 [11.17] 36.7 [10.76] 36.5 [10.70] 35.2 [10.32] 33.9 [9.94] 34.2 [10.02] 33.0 [9.67]
31.8 [9.32]
25.9 [7.59]
2.8
105
[40.6]
Sens BTUH [kW] 24.4 [7.15] 22.3 [6.54] 20.2 [5.92] 30.0 [8.79] 27.4 [8.03] 24.8 [7.27] 31.3 [9.17] 28.6 [8.38]
Power
2.9
2.9
2.8
2.9
2.9
2.8
2.9
2.9
U
R
E
Total BTUH [kW] 38.4 [11.25] 37.0 [10.84] 35.7 [10.46] 35.4 [10.37] 34.2 [10.02] 32.9 [9.64]
33.1 [9.70]
30.7 [9.00]
3.0
31.9 [9.35]
28.0 [8.21]
3.0
30.8 [9.03]
25.4 [7.44]
2.9
110
[43.3]
Sens BTUH [kW] 23.8 [6.98] 21.8 [6.39] 19.7 [5.77] 29.3 [8.59] 26.8 [7.85] 24.3 [7.12]
°F
[°C]
Power
3.0
3.0
2.9
3.0
3.0
2.9
Total BTUH [kW] 37.5 [10.99] 36.1 [10.58] 34.8 [10.20] 34.5 [10.11] 33.3 [9.76]
32.1 [9.41]
23.8 [6.98]
3.0
32.2 [9.44]
30.0 [8.79]
3.1
31.0 [9.09]
27.5 [8.06]
3.1
29.9 [8.76]
24.9 [7.30]
3.0
115
[46.1]
Sens BTUH [kW] 23.2 [6.80] 21.2 [6.21] 19.2 [5.63] 28.7 [8.41] 26.3 [7.71]
Power
3.1
3.1
3.0
3.1
3.1
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
NOTES:
➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
HEATING PERFORMANCE DATA—RJNA-A036
IDB
60°F [15.5°C]
1200 [566]
70°F [21.1°C]
1200 [566]
80°F [26.7°C]
1200 [566]
CFM [L/s]
1440 [680]
960 [453]
1440 [680]
960 [453]
1440 [680]
960 [453]
0
Total BTUH [kW] 8.9 [2.61]
8.7 [2.55]
2.1
8.6 [2.52]
2.2
7.0 [2.05]
2.3
6.9 [2.02]
2.4
6.8 [1.99]
2.4
5.3 [1.55]
2.6
5.2 [1.52]
2.6
5.1 [1.49]
2.7
O
U
T
D
O
O
R
[-17.8] Power 2.1
5
Total BTUH [kW] 12.2 [3.58] 12.0 [3.52] 11.9 [3.49] 10.4 [3.05] 10.2 [2.99] 10.1 [2.96]
8.6 [2.52]
2.6
8.5 [2.49]
2.7
8.4 [2.46]
2.7
[26.7] Power 2.1 2.2 2.2 2.4 2.4 2.5
10 Total BTUH [kW] 15.5 [4.54] 15.3 [4.48] 15.1 [4.43] 13.6 [3.99] 13.5 [3.96] 13.3 [3.90] 11.9 [3.49]
[-12.2] Power 2.2 2.2 2.3 2.4 2.5 2.5 2.6
15 Total BTUH [kW] 18.7 [5.48] 18.5 [5.42] 18.2 [5.33] 16.9 [4.95] 16.6 [4.86] 16.4 [4.81] 15.1 [4.43]
[32.2] Power 2.2 2.3 2.3 2.4 2.5 2.6 2.7
20 Total BTUH [kW] 21.8 [6.39] 21.5 [6.30] 21.2 [6.21] 20.0 [5.86] 19.7 [5.77] 19.4 [5.69] 18.3 [5.36]
[-6.6] Power 2.2 2.3 2.4 2.5 2.5 2.6 2.7
25 Total BTUH [kW] 24.8 [7.27] 24.5 [7.18] 24.1 [7.06] 23.0 [6.74] 22.7 [6.65] 22.3 [6.54] 21.3 [6.24]
[37.8] Power 2.3 2.3 2.4 2.5 2.6 2.6 2.8
30 Total BTUH [kW] 27.7 [8.12] 27.3 [8.00] 26.9 [7.88] 25.9 [7.59] 25.5 [7.47] 25.1 [7.36] 24.1 [7.06]
[-1.1] Power 2.3 2.4 2.4 2.5 2.6 2.7 2.8
35 Total BTUH [kW] 30.5 [8.94] 30.0 [8.79] 29.6 [8.67] 28.6 [8.38] 28.2 [8.26] 27.8 [8.15] 26.9 [7.88]
[43.3] Power 2.4 2.4 2.5 2.6 2.6 2.7 2.8
40 Total BTUH [kW] 33.0 [9.67] 32.6 [9.55] 32.1 [9.41] 31.2 [9.14] 30.7 [9.00] 30.3 [8.88] 29.5 [8.65]
[4.4] Power 2.4 2.5 2.5 2.6 2.7 2.7 2.9
45 Total BTUH [kW] 35.4 [10.37] 34.9 [10.23] 34.4 [10.08] 33.6 [9.85] 33.1 [9.70] 32.6 [9.55] 31.9 [9.35]
[46.1] Power 2.4 2.5 2.6 2.7 2.7 2.8 2.9
50 Total BTUH [kW] 37.6 [11.02] 37.1 [10.87] 36.6 [10.73] 35.8 [10.49] 35.3 [10.35] 34.8 [10.20] 34.1 [9.99]
[10] Power 2.5 2.5 2.6 2.7 2.8 2.8 2.9
11.8 [3.46]
2.7
11.6 [3.40]
2.8
D
R
Y
14.9 [4.37]
2.8
14.7 [4.31]
2.8
18.0 [5.28]
2.8
17.7 [5.19]
2.9
B
U
L
21.0 [6.15]
2.8
20.7 [6.07]
2.9
B
T
E
M
P
E
R
A
T
23.8 [6.98]
2.9
23.5 [6.89]
2.9
26.5 [7.77]
2.9
26.1 [7.65]
3.0
29.0 [8.50]
2.9
28.6 [8.38]
3.0
U
R
E
31.4 [9.20]
3.0
33.6 [9.85]
3.0
31.0 [9.09]
3.1
33.1 [9.70]
3.1
°F
[°C]
IDB—Indoor air dry bulb
[
] Designates Metric Conversions
15
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEMS PERFORMANCE—RJNA- SERIES
COOLING PERFORMANCE DATA—RJNA-A042
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE
CFM [L/s]
DR ➀
71°F [21.7°C]
1400 [661]
.15
67°F [19.4°C]
1400 [661]
.15
63°F [17.2°C]
1400 [661]
.15
1680 [793]
.18
1120 [529]
.11
1680 [793]
.18
1120 [529]
.11
1680 [793]
.18
1120 [529]
.11
Total BTUH [kW] 50.3 [14.74] 48.5 [14.21] 46.8 [13.72] 47.6 [13.95] 46.0 [13.48] 44.3 [12.98] 45.0 [13.19] 43.4 [12.72] 41.9 [12.28]
75
[23.9]
Sens BTUH [kW] 30.8 [9.03] 28.2 [8.26] 25.6 [7.50] 37.2 [10.90] 34.0 [9.96] 30.8 [9.03] 38.6 [11.31] 35.3 [10.35] 32.0 [9.38]
Power
2.3
2.3
2.2
2.3
2.3
2.2
2.3
2.3
2.2
O
U
T
D
O
O
R
Total BTUH [kW] 50.3 [14.74] 48.5 [14.21] 46.8 [13.72] 47.7 [13.98] 46.0 [13.48] 44.3 [12.98] 45.1 [13.22] 43.5 [12.75] 41.9 [12.28]
80
Sens BTUH [kW] 30.8 [9.03] 28.1 [8.24] 25.5 [7.47] 37.1 [10.87] 33.9 [9.94] 30.8 [9.03] 38.5 [11.28] 35.2 [10.32] 31.9 [9.35]
[26.7]
Power
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
Total BTUH [kW] 49.6 [14.54] 47.8 [14.01] 46.1 [13.51] 46.9 [13.75] 45.3 [13.28] 43.6 [12.78] 44.3 [12.98] 42.8 [12.54] 41.2 [12.07]
85
[29.4]
Sens BTUH [kW] 30.3 [8.88] 27.7 [8.12] 25.1 [7.36] 36.6 [10.73] 33.5 [9.82] 30.4 [8.91] 38.1 [11.17] 34.8 [10.20] 31.6 [9.26]
Power
2.6
2.5
2.5
2.6
2.5
2.5
2.6
2.5
2.5
D
R
Y
Total BTUH [kW] 48.3 [14.16] 46.6 [13.66] 44.9 [13.16] 45.6 [13.36] 44.0 [12.90] 42.4 [12.43] 43.0 [12.60] 41.5 [12.16] 40.0 [11.72]
90
[32.2]
Sens BTUH [kW] 29.6 [8.67] 27.1 [7.94] 24.5 [7.18] 35.9 [10.52] 32.9 [9.64] 29.8 [8.73] 37.4 [10.96] 34.2 [10.02] 31.0 [9.09]
B
U
L
Power
2.7
2.7
2.6
2.7
2.7
2.6
2.7
2.7
2.6
Total BTUH [kW] 46.7 [13.69] 45.0 [13.19] 43.4 [12.72] 44.0 [12.90] 42.5 [12.46] 40.9 [11.99] 41.4 [12.13] 40.0 [11.72] 38.5 [11.28]
95
[35]
B
Sens BTUH [kW] 28.8 [8.44] 26.3 [7.71] 23.9 [7.00] 35.1 [10.29] 32.1 [9.41] 29.1 [8.53] 36.5 [10.70] 33.4 [9.79] 30.3 [8.88]
Power
2.9
2.8
2.8
2.9
2.8
2.8
2.9
2.8
2.8
T
E
M
P
E
R
A
T
Total BTUH [kW] 45.0 [13.19] 43.4 [12.72] 41.8 [12.25] 42.4 [12.43] 40.9 [11.99] 39.4 [11.55] 39.8 [11.66] 38.4 [11.25] 37.0 [10.84]
100
[37.8]
Sens BTUH [kW] 27.9 [8.18] 25.5 [7.47] 23.1 [6.77] 34.3 [10.05] 31.3 [9.17] 28.4 [8.32] 35.7 [10.46] 32.6 [9.55] 29.6 [8.67]
Power
3.0
3.0
2.9
3.0
3.0
2.9
3.0
3.0
2.9
Total BTUH [kW] 43.5 [12.75] 42.0 [12.31] 40.4 [11.84] 40.8 [11.96] 39.4 [11.55] 38.0 [11.14] 38.2 [11.20] 36.9 [10.81] 35.6 [10.43]
105
[40.6]
Sens BTUH [kW] 27.2 [7.97] 24.9 [7.30] 22.5 [6.59] 33.5 [9.82] 30.7 [9.00] 27.8 [8.15] 34.9 [10.23] 32.0 [9.38] 29.0 [8.50]
Power
3.1
3.1
3.0
3.1
3.1
3.0
3.1
3.1
3.0
U
R
E
Total BTUH [kW] 42.4 [12.43] 40.9 [11.99] 39.4 [11.55] 39.7 [11.63] 38.3 [11.22] 36.9 [10.81] 37.1 [10.87] 35.8 [10.49] 34.5 [10.11]
110
[43.3]
Sens BTUH [kW] 26.7 [7.83] 24.4 [7.15] 22.1 [6.48] 33.0 [9.67] 30.2 [8.85] 27.4 [8.03] 34.4 [10.08] 31.5 [9.23] 28.6 [8.38]
°F
[°C]
Power
3.3
3.2
3.2
3.3
3.2
3.2
3.3
3.2
3.2
Total BTUH [kW] 41.9 [12.28] 40.4 [11.84] 39.0 [11.43] 39.3 [11.52] 37.9 [11.11] 36.5 [10.70] 36.7 [10.76] 35.4 [10.37] 34.1 [9.99]
115
[46.1]
Sens BTUH [kW] 26.5 [7.77] 24.3 [7.12] 22.0 [6.45] 32.9 [9.64] 30.1 [8.82] 27.3 [8.00] 34.3 [10.05] 31.4 [9.20] 28.4 [8.32]
Power
3.4
3.4
3.3
3.4
3.4
3.3
3.4
3.4
3.3
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
NOTES:
➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
HEATING PERFORMANCE DATA—RJNA-A042
IDB
60°F [15.5°C]
1400 [661]
70°F [21.1°C]
1400 [661]
80°F [26.7°C]
1400 [661]
CFM [L/s]
1680 [793]
1120 [529]
1680 [793]
1120 [529]
1680 [793]
1120 [529]
0
Total BTUH [kW] 9.5 [2.78]
9.4 [2.75]
2.1
9.3 [2.73]
2.1
8.7 [2.55]
2.3
8.6 [2.52]
2.4
8.5 [2.49]
2.5
7.1 [2.08]
2.6
7.0 [2.05]
2.7
6.9 [2.02]
2.7
O
U
T
D
O
O
R
[-17.8] Power 2.0
5
Total BTUH [kW] 13.9 [4.07] 13.7 [4.02] 13.5 [3.96] 13.1 [3.84] 12.9 [3.78] 12.7 [3.72] 11.5 [3.37] 11.4 [3.34] 11.2 [3.28]
[26.7] Power 2.1 2.1 2.2 2.4 2.5 2.5 2.7 2.7 2.8
10 Total BTUH [kW] 17.1 [5.01] 16.9 [4.95] 16.7 [4.89] 16.3 [4.78] 16.1 [4.72] 15.9 [4.66] 14.8 [4.34] 14.6 [4.28] 14.3 [4.19]
[-12.2] Power 2.2 2.2 2.3 2.5 2.5 2.6 2.7 2.8 2.9
15 Total BTUH [kW] 19.5 [5.71] 19.3 [5.66] 19.0 [5.57] 18.7 [5.48] 18.4 [5.39] 18.2 [5.33] 17.2 [5.04] 16.9 [4.95] 16.7 [4.89]
[32.2] Power 2.2 2.3 2.3 2.5 2.6 2.7 2.8 2.9 2.9
20 Total BTUH [kW] 21.5 [6.30] 21.2 [6.21] 20.9 [6.13] 20.6 [6.04] 20.4 [5.98] 20.1 [5.89] 19.1 [5.60] 18.8 [5.51] 18.6 [5.45]
[-6.6] Power 2.3 2.3 2.4 2.6 2.7 2.7 2.9 2.9 3.0
25 Total BTUH [kW] 23.3 [6.83] 23.0 [6.74] 22.7 [6.65] 22.5 [6.59] 22.2 [6.51] 21.8 [6.39] 20.9 [6.13] 20.6 [6.04] 20.3 [5.95]
[37.8] Power 2.3 2.4 2.5 2.7 2.7 2.8 2.9 3.0 3.1
30 Total BTUH [kW] 25.4 [7.44] 25.1 [7.36] 24.7 [7.24] 24.6 [7.21] 24.2 [7.09] 23.9 [7.00] 23.0 [6.74] 22.7 [6.65] 22.4 [6.56]
[-1.1] Power 2.4 2.5 2.5 2.7 2.8 2.9 3.0 3.1 3.2
35 Total BTUH [kW] 28.1 [8.24] 27.8 [8.15] 27.4 [8.03] 27.3 [8.00] 26.9 [7.88] 26.5 [7.77] 25.8 [7.56] 25.4 [7.44] 25.0 [7.33]
[43.3] Power 2.5 2.5 2.6 2.8 2.9 2.9 3.1 3.1 3.2
40 Total BTUH [kW] 31.9 [9.35] 31.4 [9.20] 31.0 [9.09] 31.0 [9.09] 30.6 [8.97] 30.2 [8.85] 29.5 [8.65] 29.1 [8.53] 28.7 [8.41]
[4.4] Power 2.5 2.6 2.7 2.9 2.9 3.0 3.1 3.2 3.3
45 Total BTUH [kW] 36.9 [10.81] 36.4 [10.67] 35.9 [10.52] 36.1 [10.58] 35.6 [10.43] 35.1 [10.29] 34.6 [10.14] 34.1 [9.99] 33.6 [9.85]
[46.1] Power 2.6 2.7 2.7 2.9 3.0 3.1 3.2 3.3 3.4
50 Total BTUH [kW] 43.7 [12.81] 43.1 [12.63] 42.5 [12.46] 42.9 [12.57] 42.3 [12.40] 41.7 [12.22] 41.3 [12.10] 40.8 [11.96] 40.2 [11.78]
[10] Power 2.7 2.7 2.8 3.0 3.1 3.1 3.3 3.3 3.4
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
IDB—Indoor air dry bulb
[
] Designates Metric Conversions
16
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEMS PERFORMANCE—RJNA- SERIES
COOLING PERFORMANCE DATA—RJNA-A048
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE
CFM [L/s]
DR ➀
71°F [21.7°C]
1600 [755]
.15
67°F [19.4°C]
1600 [755]
.15
63°F [17.2°C]
1600 [755]
.15
1920 [906]
.18
1280 [604]
.11
1920 [906]
.18
1280 [604]
.11
1920 [906]
.18
1280 [604]
.11
Total BTUH [kW] 59.9 [17.55] 57.8 [16.94] 55.7 [16.32] 56.2 [16.47] 54.3 [15.91] 52.3 [15.33] 53.5 [15.68] 51.7 [15.15] 49.8 [14.59]
75
[23.9]
Sens BTUH [kW] 35.6 [10.43] 32.6 [9.55] 29.5 [8.65] 43.0 [12.60] 39.3 [11.52] 35.6 [10.43] 46.0 [13.48] 42.0 [12.31] 38.1 [11.17]
Power
2.7
2.6
2.6
2.7
2.7
2.6
2.7
2.6
2.6
O
U
T
D
O
O
R
Total BTUH [kW] 58.7 [17.20] 56.6 [16.59] 54.5 [15.97] 55.0 [16.12] 53.1 [15.56] 51.2 [15.01] 52.3 [15.33] 50.5 [14.80] 48.7 [14.27]
80
Sens BTUH [kW] 35.1 [10.29] 32.1 [9.41] 29.1 [8.53] 42.5 [12.46] 38.8 [11.37] 35.2 [10.32] 45.5 [13.33] 41.6 [12.19] 37.7 [11.05]
[26.7]
Power
2.9
2.8
2.8
2.9
2.8
2.8
2.9
2.8
2.8
Total BTUH [kW] 57.4 [16.82] 55.4 [16.24] 53.4 [15.65] 53.8 [15.77] 51.9 [15.21] 50.0 [14.65] 51.1 [14.98] 49.3 [14.45] 47.5 [13.92]
85
[29.4]
Sens BTUH [kW] 34.6 [10.14] 31.6 [9.26] 28.7 [8.41] 41.9 [12.28] 38.3 [11.22] 34.7 [10.17] 44.9 [13.16] 41.1 [12.05] 37.2 [10.90]
Power
3.0
3.0
3.0
3.1
3.0
3.0
3.0
3.0
2.9
D
R
Y
Total BTUH [kW] 56.1 [16.44] 54.1 [15.86] 52.1 [15.27] 52.5 [15.39] 50.6 [14.83] 48.8 [14.30] 49.8 [14.59] 48.0 [14.07] 46.3 [13.57]
90
[32.2]
Sens BTUH [kW] 33.9 [9.94] 31.0 [9.09] 28.1 [8.24] 41.2 [12.07] 37.7 [11.05] 34.2 [10.02] 44.2 [12.95] 40.4 [11.84] 36.7 [10.76]
B
U
L
Power
3.2
3.2
3.1
3.2
3.2
3.1
3.2
3.2
3.1
Total BTUH [kW] 54.7 [16.03] 52.8 [15.47] 50.9 [14.92] 51.1 [14.98] 49.3 [14.45] 47.5 [13.92] 48.4 [14.18] 46.7 [13.69] 45.0 [13.19]
95
[35]
B
Sens BTUH [kW] 33.1 [9.70] 30.3 [8.88] 27.5 [8.06] 40.4 [11.84] 37.0 [10.84] 33.5 [9.82] 43.5 [12.75] 39.7 [11.63] 36.0 [10.55]
Power
3.4
3.4
3.3
3.4
3.4
3.3
3.4
3.3
3.3
T
E
M
P
E
R
A
T
Total BTUH [kW] 53.3 [15.62] 51.4 [15.06] 49.5 [14.51] 49.6 [14.54] 47.9 [14.04] 46.2 [13.54] 46.9 [13.75] 45.3 [13.28] 43.6 [12.78]
100
[37.8]
Sens BTUH [kW] 32.3 [9.47] 29.6 [8.67] 26.8 [7.85] 39.6 [11.61] 36.3 [10.64] 32.9 [9.64] 42.7 [12.51] 39.0 [11.43] 35.4 [10.37]
Power
3.6
3.5
3.5
3.6
3.5
3.5
3.6
3.5
3.5
Total BTUH [kW] 51.7 [15.15] 49.9 [14.62] 48.1 [14.10] 48.1 [14.10] 46.4 [13.60] 44.7 [13.10] 45.4 [13.31] 43.8 [12.84] 42.2 [12.37]
105
[40.6]
Sens BTUH [kW] 31.5 [9.23] 28.8 [8.44] 26.1 [7.65] 38.8 [11.37] 35.5 [10.40] 32.2 [9.44] 41.9 [12.28] 38.3 [11.22] 34.7 [10.17]
Power
3.8
3.7
3.6
3.8
3.7
3.7
3.7
3.7
3.6
U
R
E
Total BTUH [kW] 50.2 [14.71] 48.4 [14.18] 46.6 [13.66] 46.5 [13.63] 44.9 [13.16] 43.3 [12.69] 43.8 [12.84] 42.3 [12.40] 40.8 [11.96]
110
[43.3]
Sens BTUH [kW] 30.7 [9.00] 28.1 [8.24] 25.5 [7.47] 38.0 [11.14] 34.8 [10.20] 31.5 [9.23] 41.0 [12.02] 37.5 [10.99] 34.0 [9.96]
°F
[°C]
Power
3.9
3.9
3.8
4.0
3.9
3.8
3.9
3.9
3.8
Total BTUH [kW] 48.5 [14.21] 46.8 [13.72] 45.1 [13.22] 44.9 [13.16] 43.3 [12.69] 41.7 [12.22] 42.2 [12.37] 40.7 [11.93] 39.2 [11.49]
115
[46.1]
Sens BTUH [kW] 29.9 [8.76] 27.4 [8.03] 24.8 [7.27] 37.2 [10.90] 34.1 [9.99] 30.9 [9.06] 40.3 [11.81] 36.8 [10.79] 33.4 [9.79]
Power
4.1
4.0
4.0
4.1
4.1
4.0
4.1
4.0
4.0
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
NOTES:
➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
HEATING PERFORMANCE DATA—RJNA-A048
IDB
60°F [15.5°C]
1200 [566]
70°F [21.1°C]
1200 [566]
80°F [26.7°C]
1200 [566]
CFM [L/s]
1440 [680]
960 [453]
1440 [680]
960 [453]
1440 [680]
960 [453]
0
Total BTUH [kW] 13.5 [3.96] 13.3 [3.90] 13.1 [3.84] 13.0 [3.81] 12.8 [3.75] 12.6 [3.69] 12.0 [3.52] 11.8 [3.46] 11.6 [3.40]
[-17.8] Power 2.4 2.4 2.5 2.7 2.8 2.8 3.1 3.1 3.2
Total BTUH [kW] 17.3 [5.07] 17.1 [5.01] 16.8 [4.92] 16.8 [4.92] 16.5 [4.84] 16.3 [4.78] 15.8 [4.63] 15.5 [4.54] 15.3 [4.48]
[26.7] Power 2.4 2.5 2.6 2.8 2.8 2.9 3.1 3.2 3.3
10 Total BTUH [kW] 21.0 [6.15] 20.7 [6.07] 20.4 [5.98] 20.5 [6.01] 20.2 [5.92] 19.9 [5.83] 19.5 [5.71] 19.2 [5.63] 18.9 [5.54]
[-12.2] Power 2.5 2.5 2.6 2.8 2.9 2.9 3.2 3.2 3.3
15 Total BTUH [kW] 24.6 [7.21] 24.3 [7.12] 23.9 [7.00] 24.1 [7.06] 23.7 [6.95] 23.4 [6.86] 23.1 [6.77] 22.7 [6.65] 22.4 [6.56]
[32.2] Power 2.5 2.6 2.6 2.8 2.9 3.0 3.2 3.3 3.4
20 Total BTUH [kW] 28.1 [8.24] 27.7 [8.12] 27.3 [8.00] 27.6 [8.09] 27.2 [7.97] 26.8 [7.85] 26.6 [7.80] 26.2 [7.68] 25.8 [7.56]
[-6.6] Power 2.6 2.6 2.7 2.9 3.0 3.0 3.3 3.3 3.4
25 Total BTUH [kW] 31.5 [9.23] 31.1 [9.11] 30.6 [8.97] 31.0 [9.09] 30.6 [8.97] 30.1 [8.82] 30.0 [8.79] 29.6 [8.67] 29.1 [8.53]
[37.8] Power 2.6 2.7 2.7 2.9 3.0 3.1 3.3 3.4 3.5
30 Total BTUH [kW] 34.8 [10.20] 34.3 [10.05] 33.9 [9.94] 34.3 [10.05] 33.8 [9.91] 33.3 [9.76] 33.3 [9.76] 32.8 [9.61] 32.4 [9.50]
[-1.1] Power 2.7 2.7 2.8 3.0 3.1 3.1 3.3 3.4 3.5
35 Total BTUH [kW] 38.1 [11.17] 37.5 [10.99] 37.0 [10.84] 37.5 [10.99] 37.0 [10.84] 36.5 [10.70] 36.5 [10.70] 36.0 [10.55] 35.5 [10.40]
[43.3] Power 2.7 2.8 2.8 3.0 3.1 3.2 3.4 3.5 3.6
40 Total BTUH [kW] 41.2 [12.07] 40.6 [11.90] 40.0 [11.72] 40.7 [11.93] 40.1 [11.75] 39.5 [11.58] 39.7 [11.63] 39.1 [11.46] 38.5 [11.28]
[4.4] Power 2.8 2.8 2.9 3.1 3.2 3.2 3.4 3.5 3.6
45 Total BTUH [kW] 44.2 [12.95] 43.6 [12.78] 43.0 [12.60] 43.7 [12.81] 43.1 [12.63] 42.5 [12.46] 42.7 [12.51] 42.1 [12.34] 41.5 [12.16]
[46.1] Power 2.8 2.9 2.9 3.1 3.2 3.3 3.5 3.6 3.7
50 Total BTUH [kW] 47.2 [13.83] 46.5 [13.63] 45.8 [13.42] 46.6 [13.66] 46.0 [13.48] 45.3 [13.28] 45.6 [13.36] 45.0 [13.19] 44.3 [12.98]
[10] Power 2.8 2.9 3.0 3.2 3.3 3.3 3.5 3.6 3.7
O
U
T
D
O
O
R
5
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
IDB—Indoor air dry bulb
[
] Designates Metric Conversions
17
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEMS PERFORMANCE—RJNA- SERIES
COOLING PERFORMANCE DATA—RJNA-A060
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE
CFM [L/s]
DR ➀
71°F [21.7°C]
2000 [944]
.19
67°F [19.4°C]
2000 [944]
.19
63°F [17.2°C]
2000 [944]
.19
2500 [1180]
.22
1500 [708]
.15
2500 [1180]
.22
1500 [708]
.15
2500 [1180]
.22
1500 [708]
.15
Total BTUH [kW] 74.9 [21.95] 71.6 [20.98] 68.4 [20.05] 71.3 [20.90] 68.2 [19.99] 65.1 [19.08] 67.6 [19.81] 64.6 [18.93] 61.7 [18.08]
75
[23.9]
Sens BTUH [kW] 44.2 [12.95] 39.6 [11.61] 35.0 [10.26] 53.4 [15.65] 47.8 [14.01] 42.3 [12.40] 57.5 [16.85] 51.5 [15.09] 45.5 [13.33]
Power
4.0
3.9
3.8
3.9
3.9
3.8
3.9
3.8
3.8
O
U
T
D
O
O
R
Total BTUH [kW] 74.4 [21.80] 71.2 [20.87] 67.9 [19.90] 70.8 [20.75] 67.7 [19.84] 64.6 [18.93] 67.1 [19.67] 64.2 [18.82] 61.2 [17.94]
80
Sens BTUH [kW] 44.3 [12.98] 39.7 [11.63] 35.0 [10.26] 53.5 [15.68] 47.9 [14.04] 42.3 [12.40] 57.6 [16.88] 51.5 [15.09] 45.5 [13.33]
[26.7]
Power
4.2
4.1
4.1
4.2
4.1
4.0
4.1
4.1
4.0
Total BTUH [kW] 73.3 [21.48] 70.2 [20.57] 67.0 [19.64] 69.7 [20.43] 66.7 [19.55] 63.6 [18.64] 66.0 [19.34] 63.1 [18.49] 60.3 [17.67]
85
[29.4]
Sens BTUH [kW] 43.8 [12.84] 39.2 [11.49] 34.7 [10.17] 53.0 [15.53] 47.5 [13.92] 41.9 [12.28] 57.1 [16.73] 51.1 [14.98] 45.2 [13.25]
Power
4.5
4.4
4.3
4.4
4.3
4.2
4.4
4.3
4.2
D
R
Y
Total BTUH [kW] 71.8 [21.04] 68.7 [20.13] 65.6 [19.23] 68.2 [19.99] 65.2 [19.11] 62.3 [18.26] 64.5 [18.90] 61.7 [18.08] 58.9 [17.26]
90
[32.2]
Sens BTUH [kW] 43.0 [12.60] 38.5 [11.28] 34.0 [9.96] 52.2 [15.30] 46.7 [13.69] 41.3 [12.10] 56.3 [16.50] 50.4 [14.77] 44.5 [13.04]
B
U
L
Power
4.7
4.6
4.5
4.6
4.5
4.4
4.6
4.5
4.4
Total BTUH [kW] 70.0 [20.51] 67.0 [19.64] 63.9 [18.73] 66.4 [19.46] 63.5 [18.61] 60.6 [17.76] 62.7 [18.38] 60.0 [17.58] 57.2 [16.76]
95
[35]
B
Sens BTUH [kW] 41.9 [12.28] 37.5 [10.99] 33.2 [9.73] 51.1 [14.98] 45.8 [13.42] 40.4 [11.84] 55.2 [16.18] 49.4 [14.48] 43.7 [12.81]
Power
4.9
4.8
4.7
4.8
4.7
4.6
4.8
4.7
4.6
T
E
M
P
E
R
A
T
Total BTUH [kW] 68.0 [19.93] 65.1 [19.08] 62.1 [18.20] 64.4 [18.87] 61.6 [18.05] 58.8 [17.23] 60.7 [17.79] 58.1 [17.03] 55.4 [16.24]
100
[37.8]
Sens BTUH [kW] 40.7 [11.93] 36.5 [10.70] 32.2 [9.44] 49.9 [14.62] 44.7 [13.10] 39.5 [11.58] 54.0 [15.83] 48.4 [14.18] 42.7 [12.51]
Power
5.1
5.0
4.9
5.1
5.0
4.9
5.0
4.9
4.8
Total BTUH [kW] 66.0 [19.34] 63.1 [18.49] 60.3 [17.67] 62.4 [18.29] 59.7 [17.50] 56.9 [16.68] 58.7 [17.20] 56.1 [16.44] 53.6 [15.71]
105
[40.6]
Sens BTUH [kW] 39.6 [11.61] 35.4 [10.37] 31.3 [9.17] 48.8 [14.30] 43.7 [12.81] 38.6 [11.31] 52.8 [15.47] 47.3 [13.86] 41.8 [12.25]
Power
5.4
5.3
5.1
5.3
5.2
5.1
5.3
5.2
5.1
U
R
E
Total BTUH [kW] 64.1 [18.79] 61.3 [17.97] 58.5 [17.14] 60.5 [17.73] 57.8 [16.94] 55.2 [16.18] 56.8 [16.65] 54.3 [15.91] 51.8 [15.18]
110
[43.3]
Sens BTUH [kW] 38.5 [11.28] 34.5 [10.11] 30.5 [8.94] 47.7 [13.98] 42.7 [12.51] 37.8 [11.08] 51.8 [15.18] 46.4 [13.60] 41.0 [12.02]
°F
[°C]
Power
5.6
5.5
5.4
5.5
5.4
5.3
5.5
5.4
5.3
Total BTUH [kW] 62.4 [18.29] 59.7 [17.50] 57.0 [16.71] 58.8 [17.23] 56.2 [16.47] 53.7 [15.74] 55.1 [16.15] 52.7 [15.44] 50.3 [14.74]
115
[46.1]
Sens BTUH [kW] 37.8 [11.08] 33.8 [9.91] 29.9 [8.76] 47.0 [13.77] 42.1 [12.34] 37.2 [10.90] 51.1 [14.98] 45.7 [13.39] 40.4 [11.84]
Power
5.8
5.7
5.6
5.7
5.6
5.5
5.7
5.6
5.5
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
NOTES:
➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
HEATING PERFORMANCE DATA—RJNA-A060
IDB
60°F [15.5°C]
2000 [944]
70°F [21.1°C]
2000 [944]
80°F [26.7°C]
2000 [944]
CFM [L/s]
2500 [1180]
1500 [708]
2500 [1180]
1500 [708]
2500 [1180]
1500 [708]
0
Total BTUH [kW] 16.6 [4.86] 16.3 [4.78] 16.0 [4.69] 15.0 [4.40] 14.7 [4.31] 14.4 [4.22] 14.9 [4.37] 14.6 [4.28] 14.4 [4.22]
[-17.8] Power 3.0 3.1 3.2 3.4 3.5 3.7 3.9 4.1 4.2
Total BTUH [kW] 22.7 [6.65] 22.3 [6.54] 21.9 [6.42] 21.1 [6.18] 20.7 [6.07] 20.3 [5.95] 21.0 [6.15] 20.6 [6.04] 20.3 [5.95]
[26.7] Power 3.1 3.2 3.3 3.5 3.6 3.7 4.0 4.2 4.3
10 Total BTUH [kW] 28.5 [8.35] 28.0 [8.21] 27.5 [8.06] 26.9 [7.88] 26.4 [7.74] 25.9 [7.59] 26.8 [7.85] 26.3 [7.71] 25.9 [7.59]
[-12.2] Power 3.2 3.3 3.4 3.6 3.7 3.8 4.1 4.2 4.4
15 Total BTUH [kW] 34.0 [9.96] 33.4 [9.79] 32.8 [9.61] 32.3 [9.47] 31.8 [9.32] 31.2 [9.14] 32.3 [9.47] 31.7 [9.29] 31.1 [9.11]
[32.2] Power 3.3 3.4 3.5 3.7 3.8 3.9 4.2 4.3 4.5
20 Total BTUH [kW] 39.1 [11.46] 38.4 [11.25] 37.7 [11.05] 37.5 [10.99] 36.8 [10.79] 36.2 [10.61] 37.4 [10.96] 36.8 [10.79] 36.1 [10.58]
[-6.6] Power 3.4 3.5 3.6 3.8 3.9 4.0 4.3 4.4 4.6
25 Total BTUH [kW] 43.9 [12.87] 43.2 [12.66] 42.4 [12.43] 42.3 [12.40] 41.5 [12.16] 40.8 [11.96] 42.2 [12.37] 41.5 [12.16] 40.7 [11.93]
[37.8] Power 3.5 3.6 3.7 3.9 4.0 4.1 4.4 4.5 4.7
30 Total BTUH [kW] 48.4 [14.18] 47.6 [13.95] 46.7 [13.69] 46.8 [13.72] 46.0 [13.48] 45.1 [13.22] 46.7 [13.69] 45.9 [13.45] 45.1 [13.22]
[-1.1] Power 3.5 3.7 3.8 4.0 4.1 4.2 4.5 4.6 4.8
35 Total BTUH [kW] 52.6 [15.42] 51.7 [15.15] 50.7 [14.86] 50.9 [14.92] 50.1 [14.68] 49.2 [14.42] 50.9 [14.92] 50.0 [14.65] 49.1 [14.39]
[43.3] Power 3.6 3.7 3.9 4.0 4.2 4.3 4.6 4.7 4.8
40 Total BTUH [kW] 56.4 [16.53] 55.4 [16.24] 54.5 [15.97] 54.8 [16.06] 53.8 [15.77] 52.9 [15.50] 54.7 [16.03] 53.8 [15.77] 52.8 [15.47]
[4.4] Power 3.7 3.8 4.0 4.1 4.3 4.4 4.6 4.8 4.9
45 Total BTUH [kW] 59.9 [17.55] 58.9 [17.26] 57.8 [16.94] 58.3 [17.09] 57.3 [16.79] 56.3 [16.50] 58.2 [17.06] 57.2 [16.76] 56.2 [16.47]
[46.1] Power 3.8 3.9 4.1 4.2 4.4 4.5 4.7 4.9 5.0
50 Total BTUH [kW] 63.1 [18.49] 62.0 [18.17] 60.9 [17.85] 61.5 [18.02] 60.4 [17.70] 59.3 [17.38] 61.4 [17.99] 60.4 [17.70] 59.3 [17.38]
[10] Power 3.9 4.0 4.1 4.3 4.5 4.6 4.8 5.0 5.1
O
U
T
D
O
O
R
5
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
IDB—Indoor air dry bulb
[
] Designates Metric Conversions
18
Download from Www.Somanuals.com. All Manuals Search And Download.
AIRFLOW PERFORMANCE—RJNA- SERIES
19
Download from Www.Somanuals.com. All Manuals Search And Download.
AIRFLOW PERFORMANCE—RJNA- SERIES
20
Download from Www.Somanuals.com. All Manuals Search And Download.
AIRFLOW PERFORMANCE—RJNA- SERIES
21
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL DATA—RJNA- SERIES
ELECTRICAL DATA – RJNA SERIES
-A036CK -A036CL -A036CM -A036DK -A036DL -A036DM -A036JK -A042CK -A042CL -A042CM -A042DK -A042DL -A042DM -A042JK
Unit Operating
Voltage Range
187-253 187-253 187-253 414-506 414-506 414-506 187-253 187-253 187-253 187-253 414-506 414-506 414-506 187-253
Minimum Circuit
Ampacity
Minimum Overcurrent
Protection Device Size
Maximum Overcurrent
Protection Device Size
19/19
25/25
18/18
20/20
19/19
25/25
9
9
9
25/25
30/30
20/20
25/25
19/19
25/25
20/20
25/25
10
15
15
10
15
15
10
15
15
27/27
35/35
40/40
15
15
15
15
15
15
25/25
1
25/25
1
25/25
1
35/35
1
25/25
1
25/25
1
25/25
1
No.
Volts
1
460
3
1
460
3
1
460
3
1
460
3
1
460
3
1
460
3
1
208/230 208/230 208/230
208/230 208/230 208/230 208/230
208/230
Phase
3
3
3
1
3
3
3
3
3
3
1
HP
2.5
2.5
2.5
2.5
3450
4.8
35
1
2.5
3450
4.8
35
1
2.5
3450
4.8
35
1
2.5
3
3
3
3
3450
16.5/16.5
95/95
1
RPM
3450
3450
3450
3450
3450
3450
3450
3450
5.1
39
1
3450
5.1
39
1
3450
5.1
39
1
Amps (RLA)
Amps (LRA)
No.
9.6/9.6 9.6/9.6 9.6/9.6
15/15 10.3/10.3 10.3/10.3 10.3/10.3
77/77
1
77/77
1
77/77
1
83/83
1
77/77
1
77/77
1
77/77
1
Volts
208/230 208/230 208/230
460
1
460
1
460
1
208/230 208/230 208/230 208/230
460
1
460
1
460
1
208/230
1
Phase
1
1
1
1
1
1
1
HP
1/3
2.2
4.7
1
1/3
2.2
4.7
1
1/3
2.2
4.7
1
1/3
1
1/3
1
1/3
1
1/3
2.2
4.7
1
1/3
2.2
4.7
1
1/3
2.2
4.7
1
1/3
2.2
4.7
1
1/3
1
1/3
1
1/3
1
1/3
Amps (FLA)
Amps (LRA)
No.
2.2
2.4
1
2.4
1
2.4
1
2.4
1
2.4
1
2.4
1
4.7
1
Volts
208/230 208/230 208/230
460
1
460
3
460
3
208/230 208/230 208/230 208/230
460
1
460
3
460
3
208/230
1
Phase
1
3
3
1
1
3
3
HP
1/2
2.7
6.5
1/2
2.2
10.6
3/4
3.2
16.8
1/2
1.5
3.6
1/2
1.1
5.3
3/4
1.6
8.4
1/2
2.7
6.5
1/2
2.7
6.5
1/2
2.2
10.6
3/4
3.2
16.8
1/2
1.5
3.6
1/2
1.1
5.3
3/4
1.6
8.4
1/2
Amps (FLA)
Amps (LRA)
2.7
6.5
1. Horsepower Per Compressor.
2. Amp Draw Per Motor. Multiply Value By Number of Motors to Determine Total Amps.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL DATA—RJNA- SERIES
ELECTRICAL DATA – RJNA SERIES
-A048CK -A048CL -A048CM -A048DK -A048DL -A048DM -A048JK -A060CK -A060CL -A060CM -A060DL -A060DM -A060JK
Unit Operating
Voltage Range
187-253 187-253 187-253 414-506 414-506 414-506 187-253 187-253 187-253 187-253 414-506 414-506 187-253
Minimum Circuit
Ampacity
Minimum Overcurrent
Protection Device Size
Maximum Overcurrent
Protection Device Size
22/22
25/25
21/21
25/25
22/22
25/25
11
15
15
11
15
15
11
15
15
30/30
35/35
32/32
40/40
28/28
35/35
28/28
35/35
14
20
20
14
20
20
46/46
60/60
60/60
30/30
1
30/30
1
30/30
1
45/45
1
45/45
1
45/45
1
45/45
1
No.
Volts
1
460
3
1
460
3
1
460
3
1
460
3
1
460
3
1
208/230 208/230 208/230
208/230 208/230 208/230 208/230
208/230
Phase
3
3
3
1
3
5
3
5
3
5
1
HP
3.5
3.5
3.5
3.5
3450
6.4
44
1
3.5
3450
6.4
44
1
3.5
3450
6.4
44
1
3.5
5
5
5
RPM
3450
3450
3450
3450
3450
3450
3450
3450
8.2
62
1
3450
8.2
62
1
3450
Amps (RLA)
Amps (LRA)
No.
12.4/12.4 12.4/12.4 12.4/12.4
18.3/18.3 17.3/17.3 17.3/17.3 17.3/17.3
109/109 123/123 123/123 123/123
28.8/28.8
88/88
1
88/88
1
88/88
1
148/148
1
1
1
1
1
Volts
208/230 208/230 208/230
460
1
460
1
460
1
208/230 208/230 208/230 208/230
460
1
460
1
208/230
Phase
1
1
1
1
1
1
1
1
HP
1/3
2.2
4.7
1
1/3
2.2
4.7
1
1/3
2.2
4.7
1
1/3
1
1/3
1
1/3
1
1/3
2.2
4.7
1
1/3
2.2
4.7
1
1/3
2.2
4.7
1
1/3
2.2
4.7
1
1/3
1
1/3
1
1/3
Amps (FLA)
Amps (LRA)
No.
2.2
2.4
1
2.4
1
2.4
1
2.4
1
2.4
1
4.7
1
Volts
208/230 208/230 208/230
460
1
460
3
460
3
208/230 208/230 208/230 208/230
460
3
460
3
208/230
Phase
1
3
3
1
1
1
3
3
1
1
HP
1/2
2.7
6.5
1/2
2.2
10.6
3/4
3.2
16.8
1/2
1.5
3.6
1/2
1.1
5.3
3/4
1.6
8.4
1/2
2.7
6.5
3/4
3.2
16.8
1
3/4
1.6
8.4
1
Amps (FLA)
Amps (LRA)
7.6
0
3.8
24
1.9
12
7.6
0
1. Horsepower Per Compressor.
2. Amp Draw Per Motor. Multiply Value By Number of Motors to Determine Total Amps.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
UNITS WITH HEATER KITS—RJNA- SERIES
24
Download from Www.Somanuals.com. All Manuals Search And Download.
UNITS WITH HEATER KITS—RJNA- SERIES
25
Download from Www.Somanuals.com. All Manuals Search And Download.
UNITS WITH HEATER KITS—RJNA- SERIES
26
Download from Www.Somanuals.com. All Manuals Search And Download.
UNITS WITH HEATER KITS—RJNA- SERIES
27
Download from Www.Somanuals.com. All Manuals Search And Download.
UNITS WITH HEATER KITS—RJNA- SERIES
28
Download from Www.Somanuals.com. All Manuals Search And Download.
UNITS WITH HEATER KITS—RJNA- SERIES
29
Download from Www.Somanuals.com. All Manuals Search And Download.
UNITS WITH HEATER KITS—RJNA- SERIES
30
Download from Www.Somanuals.com. All Manuals Search And Download.
UNIT DIMENSIONS—RJNA- SERIES
UNI
PAC
HEA
[
] Designates Metric Conversions
31
Download from Www.Somanuals.com. All Manuals Search And Download.
UNIT DIMENSIONS—RJNA- SERIES
UNIT DIMENSIONS
PACKAGE
HEAT PUMPS
BOTTOM VIEW
[
] Designates Metric Conversions
32
Download from Www.Somanuals.com. All Manuals Search And Download.
UNIT DIMENSIONS—RJNA- SERIES
SELECTION PROCEDURE
1. Determine cooling and heating requirements at design
conditions.
3. Determine blower speed and power to meet the system
requirements.
At the given external static pressure of 1.1 in wg, the belt model
must be selected. Enter the belt drive blower performance table
at 1600 CFM [755 L/s] and 1.1 in wg ESP:
RPM ..................1205
Example:
Total cooling capacity ............43,600 BTUH [12.78 kW]
Sensible cooling capacity ......34,000 BTUH [9.96 kW]
Condenser entering air ..........95°F [35°C]
Evaporator entering air ..........63°F [17°C] wb/76°F [24°C] db
Indoor air flow ........................1600 CFM [755 L/s]
External static pressure..........1.1 in wg
Required efficiency ................13 SEER
Watts ..................725
Drive ..................M
4. Calculate indoor blower BTUH heat effect.
BTUH = Watts x 3.413 = 2474
2. Select unit to meet cooling requirements.
Since total cooling is within the range of 4 ton [14.07 kW] unit and
requires 13 SEER efficiency level, enter cooling performance
table, at 95°F [35°C] outdoor temperature, 63°F [17°C] wb enter-
ing indoor air, and 1600 CFM [755 L/s]:
5. Calculate net cooling capacities.
Net total cooling = 46,700 – 2474 = 44,226 BTUH [12.96 kW]
Net sensible cooling = 33,716 – 2474 = 31.242 BTUH [9.16 kW]
Total capacity..........................46,700 BTUH [13.68 kW]
Power input ............................3.3 kW
And also, at 76°F [24°C] db indoor entering air, and using the for-
mula at the bottom of the page:
Sensible capacity....................33,710 BTUH [9.87 kW]
WEIGHTS
CENTER OF GRAVITY (C.G.)
Accessory
Shipping—lbs [kg] Operating—lbs [kg]
Capacity Tons [kW]
3-5 [10.6-17.6]
A in. [mm]
381/4 [972]
B in. [mm]
253/4 [654]
Economizer
142 [64]
30 Est. [13]
90 [41]
130 [59]
25 Est. [11]
80 [36]
Power Exhaust
Horizontal Economizer
Fresh Air Damper (Manual)
Fresh Air Damper (Motorized)
Roof Curb 8"
11 [5]
9
[4]
13 [6]
11 [5]
80 [36]
88 [40]
104 [47]
Capacity Tons [kW] Corner Weights by Percentage
84 [38]
A
B
C
D
Roof Curb 14"
Roof Curb 24"
92 [42]
108 [49]
3-5 [10.6-17.6]
23% 27% 23% 27%
[
] Designates Metric Conversions
*Allow 57” for economizer on duct side.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES—RJNA- SERIES
ACCESSORY EQUIPMENT
Accessory
Model No.
Model Application
Factory Installed
3 to 5 Ton
[10.6 to 17.6 kW]
Accessory
Description
3 to 5 Ton
3 to 5 Ton
[10.6 to 17.6 kW]
[10.6 to 17.6 kW]
RXJJ-A06 (J, C, D)
RXJJ-A10 (J, C, D)
RXJJ-A11 (J, C, D)
RXJJ-A12 (J, C, D)
RXJJ-A15 (J, C, D)
RXJJ-A20 (J, C, D)
RXJJ-A21 (J, C, D)
RXJJ-A24 (J, C, D)
See Heater Kit
Electric Table
Electric Heater Kits
RJNA-
Roofcurb 14"
Roofcurb 24"
RJNA-
RJNA-
RXKG-BAD14
RXKG-BAD24
No
No
RXRX-BBCDB21
RXRX-BBCDB22
RXRX-BBCDB23
Roofcurb Adapters
RJNA-
No
RJNA-
RJNA-
RJNA-
RJNA-
RJNA-
RJNA-
RXRD-KECM3
RXRX-AV02
RXRX-AR02
RXRX-BFF04C
RXRF-FBA1
RXRF-FBB1
Economizer with Single Enthalpy ➀
Dual Enthalpy Kit
Yes
No
No
No
No
No
CO2 Sensor
Power Exhaust
Fresh Air Damper Manual
Fresh Air Damper Motorized
Rectangular to Round 18"
Duct Adapters for Concentric Diffuser
RJNA-
RXMC-CB03
No
Concentric Diffuser 18" Step
Concentric Diffuser 18" Flush
Rectangular to Round 16" Side
Louver Kit (3 Sides)
RJNA-
RJNA-
RXRN-FA60
RXRN-FA70
RXMC-BB01
RXRX-AAD01B
RXMD-B01
No
No
RJNA-
No
All RJNA Models
RJNA-
Yes
Yes
Yes
Time Delay
Low Ambient Control to 0°F [-18°C]
RJNA-
RXPZ-C01
*Voltage
NOTES: ➀ Economizer is designed for downflow
J = 208-230 VAC-1PH-60HZ D = 460 VAC-3PH-60HZ
C = 208-230 VAC-3PH-60HZ
or horizontal applications.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES—RJNA- SERIES
Roofcurb Adapters
OLD CURB MODEL ROOFCURB ADAPTER
NEW MODEL
Old Models
MEDIUM CABINET (3 TON [11 kW])
RXPA-CA21 (1)
RXRA-DB21 (2)
(-)SNC, (-)SND, (-)SNE
(-)RGE, (-)RGF, (-)RGG
(-)PNC, (-)PND
21 SERIES
22 SERIES
RXRX-BBCDB21
RXRX-BBCDB22
LARGE CABINET
(3-3.5 TON [11-12 kW])
(-)RGE, (-)RGF, (-)RGG,
RXPA-CA22 (1)
RXRA-DB22 (2)
(-)RGH (3 TON [11 kW])
RJNA
EXTRA LARGE CABINET
(3.5-5 TON [12-18 kW])
(-)SNC, (-)SND, (-)SNE
(-)RGE, (-)RGF,
(-)RGG (4-5 TON [14-18 kW])
(-)PNC, (-)PND, (-)RGH
(3.5, 4 TON [12-14 kW])
RXPA-CA23 (1)
RXRA-DB23 (2)
23 SERIES
RXRX-BBCDB23
(1) SLOPE TYPE (2) FULL PERIMETER TYPE
Model Number Identifier:
Field Installed Resistance
Heater Kits
R X J J — A 15 C
Electric Heater Kits are designed for field
installation using either single-point power
wiring or dual circuit wiring. Low voltage
plugs are provided to allow for quick
connection to the unit. Removing a block-
off panel on the unit allows the heater
elements to be inserted into the supply air
down stream from the indoor coil and
supply air blower.
Electrical Designation
J = 208-230 V, 1 PH, 60 Hz
C = 208-230 V, 3 PH, 60 Hz
D = 460 V, 3 PH, 60 Hz
Nominal Heater kW
06 = 6 kW
15 = 15 kW
10 = 10 kW
11 = 11 kW *
12 = 12 kW
20 = 20 kW
21 = 21 kW *
24 = 24 kW
* Canadian Models Only
[
] Designates Metric Conversions
Design Series
A = Initial Design
Accessory Designation
J = Electric Heater
Accessory Classification
J = Package Heat Pump
X = Accessory
R = Trade Name
35
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
TYPICAL INSTALLATION
ROOFCURBS (Full Perimeter)
Rheem’s new roofcurb design can be utilized on
I
3 through 5 ton [10.6-17.6 kW] models.
I
Two available heights (14" [356 mm] and
24" [610 mm]) for ALL models.
I
Quick assembly corners for simple and fast assembly.
I
Opening provided in bottom pan to match the
“Thru the Curb” electrical connection opening
provided on the unit base pan.
I
2" [51 mm] x 4" [102 mm] Nailer provided.
I
Insulating panels provided.
I
Sealing gasket (28" [711 mm]) provided
with Roofcurb.
I
Packaged for easy field assembly.
Roofcurb Model
RXKG-BAD14
RXKG-BAD24
Height of Curb
14" [356 mm]
24" [610 mm]
[
] Designates Metric Conversions
ROOFCURB FOR 3-5 TON
[10.6-17.6 kW] MODELS
36
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
ECONOMIZERS
RXRD-KECM3—3-5 Ton [10.6-17.6 kW] Models Single Enthalpy with Barometric Relief
RXRX-AV02—Dual Enthalpy Kit
3-5 Ton [10.6-17.6 kW] Models
RXRX-AR02—3-5 Ton [10.6-17.6 kW] Models
Optional CO2 Sensor
I
Features Honeywell Controls
I
Available factory installed or field accessory
I
Gear Driven Direct Drive Actuator
Fully Modulating (0-100%)
Low Leakage Dampers
Horizontal or Downflow Applications
Slip-In Design for Easy Installations
Plug-In Polarized 12-pin Electrical Connections
Pre-configured—No Field Adjustments Necessary
Standard Barometric Relief Damper Provided
I
I
I
I
I
I
I
I
Single Enthalpy with Dual Enthalpy Upgrade Kit
CO2 Input Sensor Available (Field Installed)
Economizer slips in complete for Downflow or
I
I
Horizontal Duct application
Field Assembled Hood Ships with Economizer
Optional Remote Minimum Position (Honeywell
I
I
#S963B1128) is Available from ProStock
Field Installed Power Exhaust Available
I
3-5 TON [10.6-17.6 kW] MODELS
[
] Designates Metric Conversions
37
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
INTEGRAL POWER EXHAUST FOR ECONOMIZER
(FIELD INSTALLED ONLY)
RXRX-BFF04C—3-5 Ton [10.6-17.6 kW] Models 208-230 V, 1 PH, 60 Hz
I
For RXRD-KECM3 Economizer
I
Downflow or horizontal applications
I
Requires separate power supply with disconnect
Adjustable switch on economizer, factory preset to
I
energize power exhaust at 95% outside air position
Polarized plug connects power exhaust relay
I
to economizer
Illustration
ST-A0903-01
POWER EXHAUST KIT FOR RXRD-ECCM(-), RXRD-EECM(-) ECONOMIZERS
High Speed
Model No.
No. of Fans
Volts
Phase
Watts (ea.)
FLA (ea.)
LRA (ea.)
RPM
CFM ➀
RXRX-BFF04C
1
208-230
1
240
2600
1700
1.06
1.9
➀ CFM is at 0" w.c. external static pressure.
FRESH AIR DAMPER
3 to 5 Ton [10.6 to 17.6 kW] Models
RXRF-FBA1 (Manual)
RXRF-FBB1 (Motorized)
I319.DGN
FRESH AIR DAMPER
[
] Designates Metric Conversions
38
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
DUCT ADAPTERS (3 TO 5 TON [10.6 TO 17.6 kW] MODELS)
Rectangular to Round
Transitions (Downflow)
RXMC-CB03 – 18" [457 mm] Round
Available in 18 inch round
to fit all units. Drops
into and secures to
RXKG- Series Roofcurbs.
For use with
Concentric Diffusers.
[
] Designates Metric Conversions
39
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
SIDE DISCHARGE CONCENTRIC DIFFUSER
RXRN-FA60 (3 to 5 Ton [10.6 to 17.6 kW] Models)
For Use With Duct Adapter (RXMC)
DIMENSIONAL DATA
Duct
Size
Model No.
A
B
C
D
E
F
G
H
I
J
K
475/8"
235/8"
113/8"
211/2"
451/2"
221/2"
111/2"
103/4"
451/2"
211/2"
71/8"
RXRN-FA60
18RD
[1210 mm] [600 mm] [289 mm] [546 mm] [1156 mm] [572 mm] [292 mm] [273 mm] [1156 mm] [546 mm] [181 mm]
ENGINEERING DATA
Static
Pressure
Throw
Feet
Neck
Vel.
Jet
Vel.
Noise
Level
Model No.
CFM [L/s]
1000 [472]
1200 [566]
1400 [661]
1600 [755]
1800 [850]
2000 [944]
2200 [1038]
.14
.17
.20
.24
.30
.36
.40
10-17
11-18
12-19
12-20
13-21
14-23
16-25
351
421
491
561
632
702
772
351
421
491
561
632
702
772
20
20
20
20
20
20
20
RXRN-FA60
[
] Designates Metric Conversions
40
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
FLUSH MOUNT CONCENTRIC DIFFUSER
RXRN-FA70 (3 to 5 Ton [10.6 to 17.6 kW] Models)
For Use With Duct Adapter (RXMC)
DIMENSIONAL DATA
Duct
Size
Model No.
A
B
C
D
E
F
G
H
475/8"
[1210 mm]
235/8"
[600 mm]
131/2"
[343 mm]
21"
[533 mm]
45"
[1143 mm]
221/2"
[572 mm]
111/4"
[286 mm]
101/2"
[267 mm]
RXRN-FA70
18RD
ENGINEERING DATA
Static
Throw
Neck
Jet
Noise
Level
Model No.
CFM [L/s]
Pressure
Feet
Vel.
391
469
547
625
703
781
859
Vel.
1000 [472]
1200 [566]
1400 [661]
1600 [755]
1800 [850]
2000 [944]
2200 [1038]
.14
.17
.20
.24
.30
.36
.40
15-20
16-22
17-24
18-25
20-28
21-29
22-30
694
833
20
25
30
30
35
40
40
972
RXRN-FA70
1111
1250
1389
1528
[
] Designates Metric Conversions
41
Download from Www.Somanuals.com. All Manuals Search And Download.
MECHANICAL SPECIFICATIONS—RJNA- SERIES
THERMOSTATS—PACKAGE HEAT PUMPS
RECOMMENDED HEAT PUMP THERMOSTATS
Units Without Economizer
Cooling
Stages
Heating
Stages
Manufacturer
Honeywell
Model
Sub-Base
T7300A1005
T8611R1166
T874R
Q7300C1006
Included
1
1
1
1
1
1
1
1
1
2
1
1
2
2
2
2
2
2
2
2
2
3
2
2
Q674F1360
Included
T841A1209
T874G1881
T8141A
Q674F1360
Included
3AAT86B8A2
3AAT83D9C1
1F59-057
1F92-71
Included
General Electric
White-Rodgers
Maple Chase
Included
Included
Included
962-0
Included
962-1
Included
Units With Economizer
Included
Honeywell
T874W1031
2
3
Coils
Manual Fresh Air Damper
SAMPLE
The evaporator and condenser coils shall
Damper shall consist of damper and rain-
SPECIFICATIONS
be fabricated of copper tubes with mechani- hood which is manually preset to admit up
cally bonded aluminum plate fins. They
shall be pressure tested prior to assembly
into the unit, and electronically leak tested
after assembly.
to 35% of outside air for field installation.
Unit shall be completely factory assembled
and performance tested to provide the
required cooling and heating functions suit-
able for outdoor installations. Unit shall be
UL/cUL listed and rated in accordance to
ARI Standard 210.
Motorized Fresh Air Damper
Damper shall consist of motor, damper, and
rainhood which can admit up to 35% of out-
side air for field installation.
Condenser Fan
A single direct drive propeller fan shall dis-
charge air vertically upward. The fan motor
shall be permanently lubricated and have
built-in overload protection.
Electric Heat Kits
Cabinet
Electric heat kits shall be available in a wide
range of capacity with branch circuit fusing
allowing single point wiring. Kits shall be
UL/cUL approved. Each kit shall be offered
as a field or factory installed option.
Unit casing, base pan and framework shall
be manufactured of galvanized sheet metal
primed and finished with powder paint
capable of withstanding a 1000-hour salt
spray test per ASTM B 117. Unit interior cab-
inet surfaces shall be insulated with a mini-
mum 1/2-inch thick foil faced insulation.
Access panels shall be easily removable
providing access to the blower, filter, heating
compartment, and compressor/control box.
Unit base rails shall be provided with fork
insertion slots and rigging holes. Conden-
sate drain pan shall be of sloped design to
conform to ASHRAE 62. Unit shall be sup-
plied ready for vertical airflow and be easily
convertible to horizontal airflow at or before
installation.
Evaporator Blower
A single, double inlet, centrifugal wheel
shall rotate in permanently lubricated ball
bearings. The wheel shall be made from
steel with corrosion resistant finish and shall
be statically and dynamically balanced.
Pressure Controls
High and low pressure controls shall be
included for field or factory installation.
Low Ambient Control
Low ambient control shall be provided to
cycle the condenser fan in response to
condensing pressure and allow operation
to 0 degrees F. The option shall be field or
factory installed.
ACCESSORIES
ROOF CURB
Curb shall be full perimeter type, complying
with the standards of the National Roofing
Contractors Association. Design shall pro-
vide for drop-in of supply and return ducts
prior to setting unit, and include an insulat-
ing panel for the rest of the curb area.
Time Delay Control
Time delay control shall be provided to
prevent the compressor from restarting 5
minutes after shutdown. The control shall
be field or factory installed.
Compressor(s)
Unit shall be provided with fully hermetic
scroll compressor(s) with internally protected
safety controls.
Economizer
Louver Panel Kits
Economizer shall be completely assembled
for field installation. Unit shall include all
controls and dampers including the baro-
metric relief damper.
Field or factory installed louver kits shall
be provided for condenser coil protection
against hail or flying debris.
[
] Designates Metric Conversions
42
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING SCHEMATICS—RJNA- SERIES
43
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING SCHEMATICS—RJNA- SERIES
44
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING SCHEMATICS—RJNA- SERIES
45
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING SCHEMATICS—RJNA- SERIES
46
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING SCHEMATICS—RJNA- SERIES
47
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING SCHEMATICS—RJNA- SERIES
48
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING SCHEMATICS—RJNA- SERIES
49
Download from Www.Somanuals.com. All Manuals Search And Download.
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM
YOUR RETAILER.
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
periods stated, in accordance with the terms of the limited
warranty.
Compressor...................................................Five (5) Years
Electric Heating Elements ...............................Five (5) Years
Any Other Part
1-Phase Models .............................................Five (5) Years
3-Phase Models...............................................One (1) Year
For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, See Your Local Installer or Contact the Manufacturer
for a Copy.
RHEEM
AIR CONDITIONING
DIVISION
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
5600 Old Greenwood Road, Fort Smith, Arkansas 72908
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A.
8-05 DC
FORM NO. P11-763 REV. 1
Supersedes Form No. P11-763
Download from Www.Somanuals.com. All Manuals Search And Download.
|
QSC Audio DJ Equipment 10 SERIES User Guide
QSC Audio Stereo Amplifier IT 42 User Guide
Radio Shack Portable Radio FRS 105 User Guide
Radio Shack Telephone ET 1754 User Guide
Raritan Computer Switch UST IP User Guide
RCA Portable CD Player RP2730 User Guide
Rotel Stereo Receiver RX 975 User Guide
Samsung Microwave Oven CM929B User Guide
Samsung Microwave Oven SMH7178STE User Guide
Sanyo Air Conditioner 101 User Guide