Reliance Water Heaters Water Heater 317686 000 User Guide

Instruction Manual  
resIdentIal Gas water heaters  
power vented Gas Models w/hot surface IGnItIon  
NOT FOR USE IN MANUFACTURED (MOBILE) HOMES  
Model 6 50YtvIt serIes 100  
Low Lead Content  
for Your safety •  
AN ODORANT IS ADDED TO THE GAS USED  
BY THIS WATER HEATER.  
all technIcal and warrantY questIons: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS  
PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.  
Keep thIs Manual In the pocKet on heater for future reference  
whenever MaIntenance adjustMent or servIce Is requIred.  
PRINTED 0810  
317686-000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General safetY InforMatIon  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
General safetY InforMatIon  
at least 18"(45.7cm) above the floor. This  
will reduce, but not eliminate, the risk  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
taBle of contents  
SAFE INSTALLATION, USE AND SERVICE................................................2  
Filling the Water Heater ................................................................17-18  
Vent Pipe Assembly...........................................................................18  
Venting...............................................................................................18  
Vent Pipe Termination........................................................................19  
Planning the Vent System..................................................................20  
Condensate ..................................................................................20-21  
Blower Assembly Installation .............................................................21  
Installation of Vent System ................................................................21  
Vent Terminal Installation, Sidewall...............................................21-22  
Installation of Vent System, Sidewall.................................................23  
Installation of Vertical Vent System....................................................23  
Vent Attenuation Assembly Installation Instructions......................24-25  
Vent Pipe Preparation...................................................................26-27  
LIGHTING & OPERATING LABEL.............................................................28  
TEMPERATURE REGULATION ................................................................29  
FOR YOUR INFORMATION.......................................................................30  
Start Up Conditions............................................................................30  
Operational Conditions ......................................................................30  
PERIODIC MAINTENANCE..................................................................30-33  
Venting System Inspection ................................................................30  
Burner Operation and Inspection.......................................................31  
Burner Cleaning.................................................................................31  
Housekeeping....................................................................................31  
Anode Rod Inspection .......................................................................31  
Temperature-Pressure Relief Valve Test............................................32  
Draining and Flushing........................................................................32  
Service...............................................................................................33  
LEAKAGE CHECKPOINTS........................................................................33  
REPAIR PARTS LIST.................................................................................34  
TROUBLESHOOTING GUIDELINES....................................................35-37  
NOTES .......................................................................................................38  
LIMITED WARRANTY................................................................................39  
APPROVALS................................................................................................2  
GENERAL SAFETY INFORMATION.........................................................3-4  
TABLE OF CONTENTS................................................................................5  
INTRODUCTION..........................................................................................5  
Qualified Installer or Service Agency ...................................................5  
Preparing for the Installation................................................................5  
INSTALLATION REQUIREMENTS FOR THE COMMONWEALTH  
OF MASSACHUSETTS................................................................................6  
TYPICAL INSTALLATION..........................................................................7-9  
Mixing Valves.......................................................................................9  
LOCATING THE NEW WATER HEATER..............................................10-13  
Facts to Consider About Location.................................................10-11  
Insulation Blankets............................................................................. 11  
Air Requirements..........................................................................11-12  
Unconfined Space .............................................................................12  
Confined Space .................................................................................12  
Fresh Air Openings for Confined Spaces ..........................................12  
Outdoor Air Through Two Openings ..................................................12  
Outdoor Air Through One Opening...............................................12-13  
Outdoor Air Through Two Horizontal Ducts .......................................13  
Outdoor Air Through Two Vertical Ducts............................................13  
Air from Other Indoor Spaces............................................................13  
INSTALLING THE NEW WATER HEATER ...........................................14-27  
Chemical Vapor Corrosion.................................................................14  
Water Piping ......................................................................................14  
Space Heating & Potable Water System ...........................................14  
Closed Water Systems ......................................................................14  
Thermal Expansion............................................................................15  
Temperature-Pressure Relief Valve ..............................................15-16  
High Altitude Installation ....................................................................16  
Gas Piping ....................................................................................16-17  
Sediment Traps..................................................................................17  
IntroductIon  
thank You for purchasing this water heater. Properly installed and  
This manual contains instructions for installation, operation,  
and maintenance of the gas-fired water heater. It also contains  
warnings throughout the manual that you must read and be  
aware of. All warnings and all instructions are essential to proper  
operation of the water heater and your safety. Since we cannot  
put everything on the first few pages, read entIre Manual  
Before atteMptInG to Install or operate the  
water heater.  
maintained, it should give you years of trouble free service.  
Abbreviations Found In This Instruction Manual:  
• CSA - Canadian Standards Association  
• ANSI - American National Standards Institute  
• NFPA - National Fire Protection Association  
• ASME - American Society of Mechanical Engineers  
• GAMA - Gas Appliance Manufacturer’s Association  
• UL - Underwriters Laboratories Inc.  
2. The installation must conform with these instructions and local  
code authority having jurisdiction. In absence of local codes,  
installation must comply with current editions of the National Fuel  
Gas Code, ANSI Z223.1/NFPA 54 and National Electrical Code,  
NFPA 70. All documents are available from Canadian Standards  
Association, 8501 East Pleasant Valley Road, Cleveland, OH  
44131. NFPA documents are also available from National Fire  
Protection Association, 1 Batterymarch Park, Quincy, MA 02269.  
This gas-fired water heater is design certified by Underwriters  
Laboratories Inc. under American National Standard/CSA Standard  
for Gas Water Heaters ANSI Z21.10.3 • CSA 4.3 (current edition).  
qualIfIed Installer or servIce aGencY  
Installation and service of this water heater requires ability equivalent  
to that of a Qualified Agency (as defined by ANSI below) in the field  
involved. Installation skills such as plumbing, air supply, venting,  
gas supply and electrical supply are required in addition to electrical  
testing skills when performing service.  
3. The water heater when installed must be grounded in accordance  
with the local codes, or in the absence of local codes: the National  
Electrical Code (NFPA 70).  
4. If after reading this manual you have any questions or do not  
understand any portion of the instructions, call the local gas utility or  
the manufacturer whose name appears on the rating plate.  
ansI Z223.1 2006 sec. 3.3.83: “Qualified Agency” - “Any individual,  
firm, corporation or company that either in person or through a  
representative is engaged in and is responsible for (a) the installation,  
testing or replacement of gas piping or (b) the connection, installation,  
testing, repair or servicing of appliances and equipment; that is  
experienced in such work; that is familiar with all precautions required;  
and that has complied with all the requirements of the authority  
having jurisdiction.”  
5. Carefully plan the place where you are going to put the water heater.  
Correct combustion, vent action, and vent pipe installation are  
very important in preventing death from possible carbon monoxide  
poisoning and fires, see Figures 1 and 2.  
Examine the location to ensure the water heater complies with the  
“Locating the New Water Heater” section in this manual.  
If you are not qualified (as defined by ANSI above) and licensed or  
certified as required by authority having jurisdiction to perform a given  
task do not attempt to perform any of the procedures described in this  
manual. If you do not understand the instructions given in this manual  
do not attempt to perform any procedures outlined in this manual.  
6. For California installation this water heater must be braced,  
anchored, or strapped to avoid falling or moving during an  
earthquake. See instructions for correct installation procedures.  
Instructions may be obtained from California Office of the State  
Architect, 400 P Street, Sacramento, CA 95814.  
preparInG for the InstallatIon  
7. Massachusetts Code requires this water heater to be installed in  
accordance with Massachusetts 248-CMR 2.00: State Plumbing  
Code and 248-CMR 5.00.  
1. Read “General Safety Information” section, page 3 and 4 of this manual  
first and then entire manual carefully. If you don’t follow safety rules,  
the water heater will not operate properly. It could cause DEATH,  
SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.  
8. Complies with SCAQMD rule #1146 and districts having equivalent  
NOx requirements.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
InstallatIon requIreMents for the coMMonwealth of Massachusetts  
coMMonwealth of Massachusetts  
InspectIon  
The state or local gas inspector of the side wall horizontally  
vented gas fueled equipment shall not approve the installation  
unless, upon inspection, the inspector observes carbon monoxide  
detectors and signage installed in accordance with the provisions  
of 248 CMR 5.08(2)(a) 1 through 4.  
For all side wall terminated, horizontally vented power vent, direct  
vent, and power direct vent gas fueled water heaters installed in  
every dwelling, building or structure used in whole or in part for  
residential purposes, including those owned or operated by the  
Commonwealth and where the side wall exhaust vent termination  
is less than seven (7) feet above finished grade in the area of  
the venting, including but not limited to decks and porches, the  
following requirements shall be satisfied:  
eXeMptIons  
The following equipment is exempt from 248 CMR 5.08(2)(a)1  
through 4:  
InstallatIon of carBon MonoXIde detectors  
1. The equipment listed in Chapter 10 entitled “Equipment Not  
Required To Be Vented” in the most current edition of NFPA  
54 as adopted by the Board; and  
At the time of installation of the side wall horizontal vented  
gas fueled equipment, the installing plumber or gasfitter shall  
observe that a hard wired carbon monoxide detector with an  
alarm and battery back-up is installed on the floor level where  
the gas equipment is to be installed. In addition, the installing  
plumber or gasfitter shall observe that a battery operated or  
hard wired carbon monoxide detector with an alarm is installed  
on each additional level of the dwelling, building or structure  
served by the sidewall horizontal vented gas fueled equipment.  
It shall be the responsibility of the property owner to secure the  
services of qualified licensed professionals for the installation of  
hard wired carbon monoxide detectors.  
2. Product Approved side wall horizontally vented gas fueled  
equipment installed in a room or structure separate from the  
dwelling, building, or structure used in whole or in part for  
residential purposes.  
Manufacturer requIreMents - Gas  
equIpMent ventInG sYsteM provIded  
WhenthemanufacturerofProductApprovedsidewallhorizontally  
vented gas equipment provides a venting system design or  
venting system components with the equipment, the instructions  
provided by the manufacturer for installation of the equipment  
and the venting system shall include:  
In the event that the side wall horizontally vented gas fueled  
equipment is installed in a crawl space or an attic, the hard wired  
carbon monoxide detector with alarm and battery back-up may  
be installed on the next adjacent floor level.  
1. Detailed instructions for the installation of the venting system  
design or the venting system components; and  
2. A complete parts list for the venting system design or venting  
system.  
In the event that the requirements of this subdivision can not be  
met at the time of completion of installation, the owner shall have  
a period of thirty (30) days to comply with the above requirements  
provided that during said thirty (30) day period, a battery operated  
carbon monoxide detector with an alarm shall be installed.  
Manufacturer requIreMents - Gas  
equIpMent ventInG sYsteM not provIded  
When the manufacturer of a Product Approved side wall  
horizontally vented gas fueled equipment does not provide the  
parts for venting the flue gases, but identifies “special venting  
systems,” the following requirements shall be satisfied by the  
manufacturer:  
approved carBon MonoXIde detectors  
Each carbon monoxide detector as required in accordance with  
the above provisions shall comply with NFPA 720 and be ANSI/  
UL 2034 listed and CSA certified.  
1. The referenced “special venting system” instructions shall  
be included with the appliance or equipment installation  
instructions; and  
sIGnaGe  
2. The “special venting systems” shall be Product Approved by  
the Board, and the instructions for that system shall include a  
parts list and detailed installation instructions.  
A metal or plastic identification plate shall be permanently  
mounted to the exterior of the building at a minimum height of  
eight (8) feet above grade directly in line with the exhaust vent A copy of all installation instructions for all Product Approved  
terminal for the horizontally vented gas fueled heating appliance side wall horizontally vented gas fueled equipment, all venting  
or equipment. The sign shall read, in print size no less than one- instructions, all parts lists for venting instructions, and/or all  
half (1/2) inch in size, “Gas vent dIrectlY Below. Keep venting design instructions shall remain with the appliance or  
clear of all oBstructIons.”  
equipment at the completion of the installation.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
tYpIcal InstallatIon  
Get to Know Your water heater - Gas Models  
a
B
c
D
f
G
h
j
K
l
M
n
o
p
vent pipe  
h h Bushing  
q
r
s
rating plate  
anode  
II nipple  
Insulation  
hot water outlet  
Outlet (120 VAC)  
Gas supply  
Main Manual Gas shuttoff valve  
Ground joint union  
dirt leg  
outer door  
union  
Inlet water shuttoff valve  
cold water Inlet  
Inlet dip tube  
temperature & pressure  
relief valve  
jj condensate tee  
KK adapter  
ll plug  
vent terminal  
drain valve  
Igniter and Main Burner  
drain pan  
Gas control valve  
control harness*  
t
u
w
X
MM vent pipe assembly #1  
nn vent pipe assembly #2  
oo vent pipe assembly #3  
pp side recirculation loop  
Inlet***  
qq side recirculation loop  
Outlet*** (not shown)  
rr vent attenuation  
Assembly (VAA) (Optional)  
ss access door  
Y
aa Motor & Blower  
cc condensate fitting  
(4 Places Shown)**  
dd plastic top  
ee on/off switch  
ff exhaust tee  
GG elbow  
replaceMent parts and delIMInG  
products  
Replacement parts and recommended delimer may be ordered through  
authorized servicers or distributors. When ordering parts, provide complete  
model and serial numbers (see rating plate), quantity and name of part  
desired. Standard hardware items may be purchased locally.  
condensate asseMBlY  
PP  
SS  
(U) NATURAL GAS MAIN BURNER  
wIth IGnIter asseMBlY  
sIde vIew  
(SEE ACCESS  
PANEL CAUTION)  
W
6 (15cm)  
MAXIMUM AIR GAP  
TO A SUITABLE  
DRAIN  
(X)  
vacuuM relIef  
valve  
*Install per  
local codes  
* cautIon harness has 120 vac. In operatIon.  
** see “plannInG the vent sYsteM”, “condensate” and “Blower asseMBlY InstallatIonfor more  
information.  
***the side recirculation loop connections may not be used as the primary water inlet and outlet connections.  
For your convenience, plugs are installed in these fittings at the factory. Remove these plugs if needed for  
your specific installation. Otherwise (as with all connections) check for leaks while filling the tank with water  
and after completing the installation.  
fIGure 1  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
tYpIcal InstallatIon  
condensate hose and draIn pan  
fIGure 1a.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
tYpIcal InstallatIon  
MIXInG valve / therMal eXpansIon tanK usaGe and space heatInG  
fIGure 2.  
heater (see Figure 3) or at hot water taps to further reduce system  
water temperature.  
MIXInG valves  
Mixing valves are available at plumbing supply stores. Consult a  
Qualified Installer or ServiceAgency. Follow mixing valve manufacturer’s  
instructions for installation of the valves.  
Water temperature over 125°F (52°C)  
can cause severe burns instantly  
resulting in severe injury or death.  
DANGER  
taBle 1.  
Children, the elderly and the physically  
or mentally disabled are at highest risk  
for scald injury.  
Time for Permanent Burns  
Time for 1st Degree Burns  
Water Temperature °F  
2nd & 3rd Degree  
(Less Severe Burns)  
(Most Severe Burns)  
110  
116  
116  
122  
131  
140  
149  
154  
(normal shower temp.)  
(pain threshold)  
35 minutes  
Feel water before bathing or showering.  
Temperature limiting devices such as  
mixing valves must be installed when  
required by codes and to ensure safe  
temperatures at fixtures.  
45 minutes  
5 minutes  
25 seconds  
5 seconds  
2 seconds  
1 seconds  
1 minute  
5 seconds  
2 seconds  
1 second  
instantaneous  
Water heated to a temperature which will satisfy clothes washing, dish  
washing, and other sanitizing needs can scald and cause permanent  
injury upon contact. Short repeated heating cycles caused by small  
hot water uses can cause temperatures at the point of use to exceed  
the water heater’s temperature setting by up to 20°F (11°C).  
(U.S. Government Memorandum, C.P.S.C., Peter L. Armstrong, Sept. 15, 1978)  
HOT WATER  
OUTLET  
12” TO 15”  
(30-38 cm)  
TEMPERED WATER  
OUTLET  
Some people are more likely to be permanently injured by hot water  
than others. These include the elderly, children, the infirm and the  
physically/mentally disabled. Table 1 shows the approximate time-  
to-burn relationship for normal adult skin. If anyone using hot water  
provided by the water heater being installed fits into one of these  
groups or if there is a local code or state law requiring a certain  
water temperature at the point of use, then special precautions  
must be taken.  
CHECK  
VALVE  
COLD  
WATER  
INLET  
MIXING  
VALVE  
CHECK  
VALVE  
TO TANK  
INLET  
In addition to using lowest possible temperature setting that satisfies  
demand of application a Mixing Valve should be installed at water  
fIGure 3.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
locatInG the new water heater  
facts to consIder aBout the locatIon  
Carefully choose an indoor location for the new water heater, because  
the placement is a very important consideration for the safety of the  
occupants in the building and for the most economical use of the  
appliance. this water heater is not for use in manufactured  
(mobile) homes or outdoor installation.  
Whether replacing an old water heater or putting the water heater in  
a new location, the following critical points must be observed:  
1. Select a location indoors as close as practical to the vent terminal or  
locationtowhichthewaterheaterventpipingisgoingtobeconnected,  
and as centralized with the water piping system as possible.  
2. Selected location must provide adequate clearances for servicing  
and proper operation of the water heater.  
Installation of the water heater must be accomplished in such a manner  
that if the tank or any connections should leak, the flow will not cause  
damage to the structure. For this reason, it is not advisable to install  
the water heater in an attic or upper floor. When such locations cannot  
be avoided, a metal drain pan should be installed under the water  
heater. Drain pans are available at your local hardware store. Such  
a drain pan must have a clearance of at least 1.0” (2.5cm) greater  
than any point on the water heater’s outer jacket and must be piped  
to an adequate drain. The pan must not restrict combustion air flow.  
For example, if a circular pan is used, it must be a minimum of 27”  
(69cm) in diameter. See Figure 1.  
Water heater life depends upon water quality, water pressure and  
the environment in which the water heater is installed. Water heaters  
are sometimes installed in locations where leakage may result in  
property damage, even with the use of a drain pan piped to a drain.  
However, unanticipated damage can be reduced or prevented by  
a leak detector or water shuttoff device used in conjunction with a  
piped drain pan. These devices are available from some plumbing  
supply wholesalers and retailers, and detect and react to leakage  
in various ways:  
• Sensors mounted in the drain pan that trigger an alarm or turn off the  
incoming water to the water heater when leakage is detected.  
• Sensors mounted in the drain pan that turn off the water supply to  
the entire building when water is detected in the drain pan.  
• Water supply shuttoff devices that activate based on the water  
pressure differential between the cold water and hot water pipes  
connected to the water heater.  
• Devices that will turn off the gas supply to a gas water heater while  
at the same time shutting off its water supply.  
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS  
(VAPORS) ARE LIKELY TO BE PRESENT OR STORED  
(GARAGES, STORAGE AND UTILITY AREAS, ETC.): Flammable  
liquids (such as gasoline, solvents, propane (LP or butane, etc.) and  
other substances (such as adhesives, etc.) emit flammable vapors  
which can be ignited by a gas water heater’s hot surface igniter or  
main burner. The resulting flashback and fire can cause death or  
serious burns to anyone in the area.  
This water heater must not be installed directly on carpeting.  
Carpeting must be protected by metal or wood panel beneath the  
appliance extending beyond the full width and depth of the appliance  
by at least 3” (7.6 cm) in any direction, or if the appliance is installed  
Also, the water heater must be located and/or protected so it is not  
subject to physical damage by a moving vehicle.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
in an alcove or closet, the entire floor must be covered by the panel.  
Failure to heed this warning may result in a fire hazard.  
If this water heater will be used in beauty shops, barber shops,  
cleaning establishments, or self-service laundries with dry cleaning  
equipment, it is imperative that the water heater or water heaters  
be installed so that combustion and ventilation air be taken from  
outside these areas.  
Propellants of aerosol sprays and volatile compounds, (cleaners,  
chlorine based chemicals, refrigerants, etc.) in addition to being highly  
flammable in many cases, will also react to form corrosive hydrochloric  
acid when exposed to the combustion products of the water heater.  
The results can be hazardous, and also cause product failure.  
InsulatIon BlanKets  
Insulation blankets are available to the general public for external  
use on gas water heaters but are not necessary with these products.  
The purpose of an insulation blanket is to reduce standby heat loss  
encountered with storage tank heaters. Your water heater meets or  
exceeds the Energy PolicyAct standards with respect to insulation and  
standby loss requirements, making an insulation blanket unnecessary.  
Minimum clearances between water heater and combustible  
construction are 0 inch at the sides and rear, 5.5” (14.0 cm) from the  
front and 12” (30.5 cm) from top. (Standard clearance.) If clearances  
stated on the heater differ from standard clearances, install water  
heater according to clearances stated on the heater.  
Should you choose to apply an insulation blanket to this heater, you  
should follow these instructions (For identification of components  
mentioned below, see Figure 1). Failure to follow these instructions can  
restrict the air flow required for proper combustion, potentially resulting  
in fire, asphyxiation, serious personal injury or death.  
Adequate clearance 24” (61.0 cm) for servicing this appliance should  
be considered before installation, such as changing the anodes, etc.  
A minimum clearance of 5.5” (14.0 cm) must be allowed for access  
to replaceable parts such as thermostats, drain valve, relief valve  
and condensate drain.  
When installing the heater, consideration must be given to proper  
location. Location selected should be as close to the wall as practicable  
and as centralized with the water piping system as possible.  
FIGURE 4.  
Do not apply insulation to the top of the water heater, as this will  
interfere with safe operation of the blower assembly.  
Do not cover the outer door, thermostat or temperature & pressure  
relief valve.  
Do not allow insulation to come within 2” (5.1 cm) of the floor to  
prevent blockage of combustion air flow to the burner.  
Do not cover the instruction manual. Keep it on the side of the  
water heater or nearby for future reference.  
Agas water heater cannot operate properly without the correct amount  
of air for combustion. Do not install in a confined area such as a closet,  
unless you provide air as shown in the “Locating The New Water  
Heater” section. Never obstruct the flow of ventilation air. If you have  
any doubts or questions at all, call your gas supplier. Failure to provide  
the proper amount of combustion air can result in a fire or explosion  
and cause death, serious bodily injury, or property damage.  
Do obtain new warning and instruction labels from the manufacturer  
for placement on the blanket directly over the existing labels.  
Do inspect the insulation blanket frequently to make certain it  
does not sag, thereby obstructing combustion air flow.  
aIr requIreMents  
For safe operation an adequate supply of fresh uncontaminated  
air for combustion and ventilation must be provided.  
An insufficient supply of air can cause recirculation of combustion  
products resulting in contamination that may be hazardous to life.  
fIGure 5.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Such a condition often will result in a yellow, luminous burner  
flame, causing sooting of the combustion chamber, burners and  
flue tubes and creates a risk of asphyxiation.  
free area and metal louvers and grilles will have 75% free area. Non  
motorized louvers and grilles should be fixed in the open position.  
fresh aIr openInGs for confIned spaces  
Do not install the water heater in a confined space unless an  
adequate supply of air for combustion and ventilation is brought in  
to that space using the methods described in the Confined Space  
section that follows.  
The following instructions should be used to calculate the size,  
number and placement of openings providing fresh air for combustion,  
ventilation and dilution in confined spaces. The illustrations shown in  
this section of the manual are a reference for the openings that provide  
fresh air into confined spaces only. Do not refer to these illustrations  
for the purpose of vent installation. See Installation of Vent System on  
pages 18-27 for complete venting installation instructions.  
Never obstruct the flow of ventilation air. If you have any doubts or  
questions at all, call your gas supplier. Failure to provide the proper  
amount of combustion air can result in a fire or explosion and cause  
property damage, serious bodily injury or death.  
outdoor aIr throuGh two openInGs  
unconfIned space  
An Unconfined Space is one whose volume is not less than 50 cubic  
feet per 1,000 Btu/hr (4.8 cubic meters per kW) of the total input  
rating of all appliances installed in the space. Rooms communicating  
directly with the space, in which the appliances are installed, through  
openings not furnished with doors, are considered a part of the  
unconfined space.  
Makeup air requirements for the operation of exhaust fans, kitchen  
ventilation systems, clothes dryers and fireplaces should also be  
considered in determining the adequacy of a space to provide  
combustion, ventilation and dilution air.  
unusuallY tIGht constructIon  
In unconfined spaces in buildings, infiltration may be adequate to  
provide air for combustion, ventilation and dilution of flue gases.  
However, in buildings of unusually tight construction (for example,  
weather stripping, heavily insulated, caulked, vapor barrier, etc.)  
additional air must be provided using the methods described in the  
Confined Space section that follows.  
confIned space  
fIGure 6.  
A Confined Space is one whose volume is less than 50 cubic feet  
per 1,000 Btu/hr (4.8 cubic meters per kW) of the total input rating  
of all appliances installed in the space.  
The confined space should be provided with two permanent  
openings, one commencing within 12 inches (300 mm) of the top  
and one commencing within 12 inches (300 mm) of the bottom of  
the enclosure. The openings should communicate directly with  
the outdoors. See Figure 6.  
Openings must be installed to provide fresh air for combustion,  
ventilation and dilution in confined spaces. The required size for the  
openings is dependent on the method used to provide fresh air to  
the confined space and the total Btu/hr input rating of all appliances  
installed in the space.  
Each opening should have a minimum free area of 1 square inch  
per 4,000 Btu/hr (550 mm2 per kW) of the aggregate input rating  
of all appliances installed in the enclosure. Each opening should  
not be less than 100 square inches (645 cm2).  
dIrect vent applIances  
outdoor aIr throuGh one openInG  
Appliances installed in a Direct Vent configuration that derive all  
air for combustion from the outdoor atmosphere through sealed  
intake air piping are not factored in the total appliance input Btu/hr  
calculations used to determine the size of openings providing fresh  
air into confined spaces.  
eXhaust fans  
Where exhaust fans are installed, additional air should be provided  
to replace the exhausted air. When an exhaust fan is installed in  
the same space with a water heater, sufficient openings to provide  
fresh air must be provided that accommodate the requirements for  
all appliances in the room and the exhaust fan. Undersized openings  
will cause air to be drawn into the room through the water heater’s  
vent system causing poor combustion. Sooting, serious damage to  
the water heater and the risk of fire or explosion may result. It can  
also create a risk of asphyxiation.  
louvers and GrIlles  
Thefreeareasoffreshairopeningsininstructionsthatfollowdonottake  
in to account presence of louvers, grilles or screens in openings.  
The required size of openings for combustion, ventilation and dilution  
air should be based on the “net free area” of each opening. Where  
the free area through a design of louver or grille or screen is known, it  
shouldbeusedincalculatingthesizeofopeningrequiredtoprovidethe  
free area specified. Where the louver and grille design and free area  
are not known, it should be assumed that wood louvers will have 25%  
fIGure 7.  
Alternatively a single permanent opening, commencing within 12  
inches (300 mm) of the top of the enclosure, should be provided. See  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 7. The water heater should have clearances of at least 1 inch The confined space should be provided with two permanent vertical  
(25 mm) from the sides and back and 6 inches (150 mm) from the front  
of the appliance. The opening should directly communicate with the  
outdoors or should communicate through a vertical or horizontal duct  
to the outdoors or spaces that freely communicate with the outdoors  
and should have a minimum free area of the following:  
ducts, one commencing within 12 inches (300 mm) of the top and  
one commencing within 12 inches (300 mm) of the bottom of the  
enclosure. The vertical ducts should communicate directly with the  
outdoors. See Figure 9.  
Each duct opening should have a minimum free area of 1 square inch  
per 4,000 Btu/hr (550 mm2 per kW) of the aggregate input rating of  
all appliances installed in the enclosure.  
1. 1 square inch per 3000 Btu/hr (700 mm2 per kW) of the total input  
rating of all appliances located in the enclosure, and  
2. Not less than the sum of the areas of all vent connectors in space.  
When ducts are used, they should be of the same cross sectional  
area as the free area of the openings to which they connect. The  
minimum dimension of rectangular air ducts should be not less than  
3 inches.  
outdoor aIr throuGh two horIZontal ducts  
aIr froM other Indoor spaces  
fIGure 8.  
Confined space should be provided with two permanent horizontal  
ducts, one commencing within 12 inches (300 mm) of top and one  
commencingwithin12inches(300mm)ofbottomofenclosure. Horizontal  
ducts should communicate directly with outdoors. See Figure 8.  
Each duct opening should have a minimum free area of 1 square inch  
per 2,000 Btu/hr (1100 mm2 per kW) of the aggregate input rating of all  
appliances installed in the enclosure.  
fIGure 9a.  
The confined space should be provided with two permanent  
openings, one commencing within 12 inches (300 mm) of the top  
and one commencing within 12 inches (300 mm) of the bottom of  
the enclosure. See Figure 9A.  
When ducts are used, they should be of the same cross sectional area  
as the free area of the openings to which they connect. The minimum  
dimension of rectangular air ducts should be not less than 3 inches.  
outdoor aIr throuGh two vertIcal ducts  
Each opening should communicate directly with an additional room(s)  
of sufficient volume so that the combined volume of all spaces meets  
the criteria for an Unconfined Space.  
The illustrations shown in this section of the manual are a reference for  
the openings that provide fresh air into confined spaces only.  
Each opening should have a minimum free area of 1 square inch per  
1,000 Btu/hr (1100 mm2 per kW) of the aggregate input rating of all  
appliances installed in the enclosure. Each opening should not be  
less than 100 square inches (645 cm2).  
Do not refer to these illustrations for the purpose of vent installation.  
See Installation of Vent System on pages 18-27 for complete venting  
installation instructions.  
fIGure 9.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
InstallInG the new water heater  
This water heater should not be connected to any heating systems or  
component(s) used with a non-potable water heating appliance.  
cheMIcal vapor corrosIon  
CORROSION OF THE FLUEWAYS AND VENT SYSTEM MAY  
OCCUR IF AIR FOR COMBUSTION CONTAINS CERTAIN CHEMICAL  
VAPORS. SUCH CORROSION MAY RESULT IN FAILURE AND  
RISK OF ASPHYXIATION.  
All piping components connected to this unit for space heating  
applications should be suitable for use with potable water.  
Toxic chemicals, such as those used for boiler treatment should not  
be introduced into this system.  
Spray can propellants, cleaning solvents, refrigerator and air  
conditioning refrigerants, swimming pool chemicals, calcium and  
sodium chloride (water softener salt), waxes, and process chemicals  
are typical compounds which are potentially corrosive.  
When the system requires water for space heating at temperatures  
higher than required for domestic water purposes, a mixing  
valve must be installed. Please refer to Figure 2 for suggested  
piping arrangement.  
Do not store products of this sort near the heater. Also, air which is  
brought in contact with the heater should not contain any of these  
chemicals. If necessary, uncontaminated air should be obtained from  
remote or outside sources. The limited warranty is voided when failure  
of water heater is due to a corrosive atmosphere. (See limited warranty  
for complete terms and conditions).  
space heatInG and potaBle water sYsteM  
This appliance has been design certified as complying with  
American National Standard/CSA Standard for water heaters  
and is considered suitable for Water (Potable) Heating and  
Space Heating.  
water pIpInG  
Your water heater is equipped with inlet/outlet connections  
for use in space heating applications (see Figure 2). If this  
water heater is to be used to supply both space heating and  
potable (drinking) water, the instructions listed below must  
be followed:  
Water temperature over 125°F (52°C)  
DANGER  
can cause severe burns instantly  
resulting in severe injury or death.  
Children, the elderly and the physically  
or mentally disabled are at highest  
risk for scald injury.  
• Be sure to follow the manual(s) shipped with the air handler or other  
type heating system.  
Feel water before bathing or showering.  
• This water heater is not to be used as a replacement for an existing  
boiler installation.  
Temperature limiting valves are  
available.  
• Do not use with piping that has been treated with chromates, boiler  
seal or other chemicals and do not add any chemicals to the water  
heater piping  
Read instruction manual for safe  
temperature setting.  
• If the space heating system requires water temperatures in excess of  
120°F (49°C), a mixing valve must be installed per the manufacturer’s  
instructions in the potable hot water supply to limit the risk of scald  
injury.  
HOTTER WATER CAN SCALD:  
Water heaters are intended to produce hot water. Water heated to  
a temperature which will satisfy space heating, clothes washing,  
dish washing, cleaning and other sanitizing needs can scald and  
permanently injure you upon contact. Some people are more likely  
to be permanently injured by hot water than others. These include  
the elderly, children, the infirm, or physically/mentally handicapped.  
If anyone using hot water fits into one of these groups or if there is  
a local code or state law requiring a certain temperature water at the  
hot water tap, then you must take special precautions. In addition to  
using lowest possible temperature setting that satisfies your hot water  
needs, a means such as a mixing valve, should be used at hot water  
taps used by these people or at the water heater, see Figure 2. Valves  
• Pumps, valves, piping and fi ttings must be compatible with potable  
water.  
• A properly installed flow control valve is required to prevent  
thermosiphoning. Thermosiphoning is the result of a continuous  
flow of water through the air handler circuit during the off cycle.  
Weeping (blow off) of the temperature and pressure relief valve  
(T & P) or higher than normal water temperatures are the first signs  
of thermosiphoning.  
for reducing point of use temperature by mixing cold and hot water are • The hot water line from the water heater should be vertical past  
also available:  
any mixing valve or supply line to the heating system to remove air  
bubbles from the system.  
Consult a Qualified Installer or Service Agency. Follow manufacturer’s  
instructions for installation of valves. Before changing the factory setting  
on thermostat, read “Temperature Regulation” section in this manual.  
• Do not connect the water heater to any system or components  
previously used with non-potable water heating appliances when  
used to supply potable water.  
closed water sYsteMs  
Water supply systems may, because of code requirements or such  
conditions as high line pressure, among others, have installed  
devices such as pressure reducing valves, check valves, and back  
flow preventers. Devices such as these cause the water system to  
be a closed system.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
duct tape, electrical tape, or equivalent. IMPORTANT: The insulation  
and tape must not block the discharge opening or hinder access to the  
manual relief lever (Figure 11). Ensure a discharge pipe is installed into  
the T&P valve discharge opening per the instructions in this manual.  
4. Locate the hot water (outlet) & cold water (inlet) pipes to the water heater.  
5. Locate the slit running the length of a section of pipe insulation.  
6. Spread the slit open and slip the insulation over the cold water (inlet)  
pipe. Apply gentle pressure along the length of the insulation to ensure  
that it is fully seated around the pipe. Also, ensure that the base of  
the insulation is flush with the water heater. Once seated, secure the  
insulation with duct tape, electrical tape, or equivalent.  
therMal eXpansIon  
As water is heated, it expands (thermal expansion). In a closed system  
the volume of water will grow when it is heated. As the volume of water  
grows there will be a corresponding increase in water pressure due to  
thermal expansion. Thermal expansion can cause premature tank failure  
(leakage). This type of failure is not covered under the limited warranty.  
Thermal expansion can also cause intermittent Temperature-Pressure  
Relief Valve operation: water discharged from valve due to excessive  
pressure build up. This condition is not covered under the limited warranty.  
The Temperature-Pressure Relief Valve is not intended for constant relief  
of thermal expansion.  
7. Repeat steps 5 and 6 for the hot water (outlet) pipe.  
A properly sized thermal expansion tank must be installed on  
all closed systems to control the harmful effects of thermal  
expansion. Contact a local plumbing service agency to have a  
thermal expansion tank installed.  
8. Add additional sections of pipe insulation as needed.  
note: to protect against untimely corrosion of hot and cold water  
fittings, it is strongly recommended that di-electric unions or couplings  
be installed on this water heater when connected to copper pipe.  
All gas piping must comply with local codes and ordinances or with the  
National Fuel Gas Code (ANSI Z223.1/ NFPA-54). Copper and brass tubing  
and fittings (except tin lined copper tubing) should not be used.  
fIGure 11.  
teMperature-pressure relIef valve  
Explosion Hazard  
Temperature-Pressure Relief Valve  
must comply with ANSI Z21.22-  
CSA 4.4 and ASME code.  
Properly sized Temperature-Pressure  
Relief Valve must be installed in  
opening provided.  
Can result in overheating and  
excessive tank pressure.  
Can cause serious injury or death.  
This water heater is provided with a properly rated/sized and certified  
combination Temperature-Pressure Relief Valve (T&P valve) by the  
manufacturer. The valve is certified by a nationally recognized testing  
laboratory that maintains periodic inspection of production of listed  
equipment of materials as meeting the requirements for Relief Valves  
for Hot Water Supply Systems, ANSI Z21.22 • CSA 4.4, and the code  
requirements of ASME.  
If replaced, the new T&P valve must meet the requirements of local  
codes, but not less than a combination Temperature-Pressure Relief  
Valve rated/sized and certified as indicated in the above paragraph.  
The new valve must be marked with a maximum set pressure not to  
exceed the marked hydrostatic working pressure of the water heater  
(150 psi = 1,035 kPa) and a discharge capacity not less than the water  
heater Btu/hr or kW input rate as shown on the water heater’s model  
rating plate.  
Note: In addition to the factory installed Temperature-Pressure Relief  
Valve on the water heater, each remote storage tank that may be  
installed and piped to a water heating appliance must also have its  
own properly sized, rated and approved Temperature-Pressure Relief  
Valve installed. Call the toll free technical support phone number listed  
on the back cover of this manual for technical assistance in sizing a  
Temperature-Pressure Relief Valve for remote storage tanks.  
fIGure 10.  
Figure 10 shows typical attachment of water piping to the water heater.  
The water heater is equipped with 3/4 inch NPT water connections.  
note: If using copper tubing, solder tubing to an adapter before  
attaching the adapter to the water heater connections. do not solder  
the water lines directly to the water heater connections. It will harm  
the dip tube and damage the tank.  
For safe operation of the water heater, the Temperature-Pressure  
Relief Valve must not be removed from its designated opening nor  
plugged. The Temperature-Pressure Relief Valve must be installed  
directly into the fitting of the water heater designed for the relief  
valve. Install discharge piping so that any discharge will exit the  
pipe within 6 inches (15.2 cm) above an adequate floor drain,  
or external to the building. In cold climates it is recommended  
that it be terminated at an adequate drain inside the building. Be  
certain that no contact is made with any live electrical part. The  
t & p valve and pipe Insulation  
1. Locate the temperature and pressure relief valve on the water heater  
(also known as a T&P relief valve). See Figure 11.  
2. Locate the slit running the length of the T&P relief valve insulation.  
3. Spread the slit open and fit the insulation over the T&P relief valve. See  
Figure 11. Apply gentle pressure to the insulation to ensure that it is fully  
seated on the T&P Relief Valve. Once seated, secure the insulation with  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
discharge opening must not be blocked or reduced in size under any  
circumstances. Excessive length, over 30 feet (9.14 m), or use of  
more than four elbows can cause restriction and reduce the discharge  
capacity of the valve.  
hIGh altItude InstallatIon  
No valve or other obstruction is to be placed between the  
Temperature-Pressure Relief Valve and the tank. Do not connect  
discharge piping directly to the drain unless a 6” (15.2 cm) air gap is  
provided. To prevent bodily injury, hazard to life, or property damage,  
the relief valve must be allowed to discharge water in adequate  
quantities should circumstances demand. If the discharge pipe is  
not connected to a drain or other suitable means, the water flow  
may cause property damage.  
CAUTION  
Water Damage Hazard  
Temperature-Pressure Relief Valve discharge  
pipe must terminate at adequate drain.  
This heater is approved for operation up to 5,300 feet (1,615 m)  
without alteration. High altitude models are available from the factory  
for elevations between 5,300 feet (1,615 m) and 10,100 feet (3,079  
m). For elevations above 10,100 feet (3,079 m) the input rating  
should be reduced at the rate of 4 percent for each 1,000 feet (305  
m) above sea level which requires replacement of the burner orifice  
in accordance with National Fuel Gas Code (ANSI Z223.1/NFPA 54).  
Contact your local gas supplier for further information.  
t&p valve discharge pipe requirements:  
• Should not be smaller in size than the outlet pipe size of the valve, or  
have any reducing couplings or other restrictions.  
• Should not be plugged or blocked.  
• Should not be exposed to freezing temperatures.  
• Should be of material listed for hot water distribution.  
Failure to replace standard orifice with a high altitude orifice when  
installed above 10,100 feet (3,079 m) could result in improper and  
inefficient operation of the appliance, producing carbon monoxide  
gas in excess of safe limits, which could result in serious injury or  
death. Contact your gas supplier for any specific changes which  
may be required in your area.  
• Should be installed so as to allow complete drainage of both the  
Temperature-Pressure Relief Valve and the discharge pipe.  
• Must terminate a maximum of six inches above a floor drain or external  
to the building. In cold climates, it is recommended that the discharge  
pipe be terminated at an adequate drain inside the building.  
• Should not have any valve or other obstruction between the relief  
valve and the drain.  
Gas pIpInG  
DANGER  
Burn hazard.  
Fire and Explosion Hazard  
Hot water discharge.  
Do not use water heater with any  
gas other than the gas shown on  
the rating plate.  
Keep clear of Temperature-  
Pressure Relief Valve  
discharge outlet.  
Excessive pressure to gas control  
valve can cause serious injury or death  
Turn off gas lines during installation.  
Contact qualified installer or  
service agency.  
TheTemperature-Pressure Relief Valve must be manually operated at  
least twice a year. Caution should be taken to ensure that (1) no one  
is in front of or around the outlet of the Temperature-Pressure Relief  
Valve discharge line, and (2) the water manually discharged will not  
cause any bodily injury or property damage because the water may be  
extremelyhot. Ifaftermanuallyoperatingthevalve, itfailstocompletely  
reset and continues to release water, immediately close the cold water  
inlet to the water heater, follow the draining instructions in this manual,  
and replace the Temperature-Pressure Relief Valve with a properly  
rated/sized new one.  
Make sure the gas supplied is the same type listed on the model  
rating plate. The inlet gas pressure must not exceed 14 inch water  
column (3.5 kPa) for natural and propane gas (L.P.). The minimum  
inlet gas pressure shown on the rating plate is that which will permit  
firing at rated input.  
All gas piping must comply with local codes and ordinances or with the  
National Fuel Gas Code (ANSI Z223.1/ NFPA-54). Copper or brass  
tubing and fittings (except tin lined copper tubing) should not be  
used.  
note: The purpose of a Temperature-Pressure Relief Valve is to  
prevent excessive temperatures and pressures in the storage tank.  
The T&P valve is not intended for the constant relief of thermal  
expansion.Aproperly sized thermal expansion tank must be installed  
on all closed systems to control thermal expansion, see Closed Water  
Systems and Thermal Expansion on page 14 and 15.  
If the gas control valve is subjected to pressures exceeding 1/2 psi  
(3.5 kPa), the damage to the gas control valve could result in a fire  
or explosion from leaking gas.  
If the main gas line Shuttoff serving all gas appliances is  
used, also turn “off” the gas at each appliance. Leave all  
gas appliances shut “off” until the water heater installation  
is complete.  
If you do not understand these instructions or have any questions  
regarding the Temperature-Pressure Relief Valve call the  
toll free number listed on the back cover of this manual for  
technical assistance.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A gas line of sufficient size must be run to the water heater.  
Consult the current edition of National Fuel Gas Code (ANSI  
Z223.1/NFPA 54) and your gas supplier concerning pipe size.  
sedIMent traps  
There must be:  
• A readily accessible manual shuttoff valve in the gas supply line  
serving the water heater, and  
• A drip leg (sediment trap) ahead of gas control valve to help prevent  
dirt and foreign materials from entering the gas control valve.  
Aexible gas connector or a ground joint union between the shuttoff  
valve and control valve to permit servicing of the unit.  
Be sure to check all the gas piping for leaks before lighting the water  
heater. Use a soapy water solution, not a match or open flame. Rinse  
off soapy solution and wipe dry.  
A sediment trap should be installed as close to the inlet of the  
water heater as practical at the time of water heater installation.  
The sediment trap should be either a tee fitting with a capped  
nipple in the bottom outlet or other device recognized as an  
effective sediment trap. If a tee fitting is used, it should be  
installed in conformance with one of the methods of installation  
shown in Figures 12 and 13.  
Contaminants in the gas lines may cause improper operation  
of the gas control valve that may result in fire or explosion.  
Before attaching the gas line be sure that all gas pipe is clean  
on the inside. To trap any dirt or foreign material in the gas  
supply line, a drip leg (sometimes called a sediment trap) must  
be incorporated in the piping. The drip leg must be readily  
accessible. Install in accordance with the “Gas Piping” section.  
Refer to the current edition of the National Fuel Gas Code  
(ANSI Z223.1/NFPA 54).  
Use pipe joint compound or teflon tape marked as being resistant  
to the action of petroleum [Propane (L.P.)] gases.  
The appliance and its gas connection must be leak tested before  
placing the appliance in operation.  
The appliance and its individual Shuttoff valve should be disconnected  
from the gas supply piping system during any pressure testing of that  
systemattestpressuresinexcessof1/2poundpersquareinch(3.5kPa).  
It should be isolated from the gas supply piping system by closing its  
individual manual Shuttoff valve during any pressure testing of the gas  
supply piping system at test pressures equal to or less than 1/2 pound  
per square inch (3.5 kPa).  
Connecting gas piping to the gas control valve of water heater can be  
accomplished by either of two methods shown in Figures 12 and 13.  
fIGure 12. Gas pIpInG wIth  
fleXIBle connector.  
FIGURE 14.  
fIllInG the water heater  
fIGure 13. Gas pIpInG wIth all  
BlacK Iron pIpe to Gas control.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Neverusethiswaterheaterunlessitiscompletelyfullofwater. Toprevent see Figure 16. Disassemble the parts and cement back together  
damagetothetank,thetankmustbelledwithwater.Watermustowfrom using the alignment marks. After the cement dries, attach the  
the hot water faucet before turning “ON” gas to the water heater.  
assembly to the blower and the water heater exhaust using the  
supplied rubber boots and hose clamps.  
To ll the water heater with water:  
1. Close the water heater drain valve by turning handle to the right  
(clockwise). The drain valve is on the lower front of water heater.  
2. Open the cold water supply valve to the water heater.  
note: the cold water supply valve must be left open when the  
water heater is in use.  
Acondensatetrapisincorporatedinthebottomofthisventpipeassembly.  
See the CONDENSATE section of this manual for further details.  
ventInG  
3. To insure complete filling of the tank, allow air to exit by opening nearest  
hot water faucet. Allow water to run until a constant flow is obtained.  
This will let air out of the water heater and the piping.  
4. Check all water piping and connections for leaks. Repair as needed.  
vent pIpe asseMBlY  
There are three parts of the vent pipe assembly that connect the water  
heater exhaust (located on lower back side of water heater) to inlet of the  
blower assembly (mounted on top of water heater) as shown in Figure  
1. These parts will need to be assembled according to the instructions  
in the VENT PIPE PREPARATION section of this manual. These PVC  
parts should be assembled with ASTM D-2564 grade cement.  
Assemble Vent Pipe Assemblies #1, #2 and #3 (See Figure 1) prior  
to cementing. The preferred orientation of Vent Pipe Assembly #1  
(Condensate U-Assembly) is shown in Figure 16. However this  
assembly may be rotated to a different orientation as needed for the  
specific installation requirements. Note the rotational orientation of  
each part by marking a line several inches long across the joints.The  
long tube of Vent Pipe Assembly #2 should be approximately  
vertical. If it is found that either of the two pieces of pipe in Vent  
Pipe Assembly #2 are too long for proper fit-up, then remove as  
little material as possible to improve the fit-up. Keep in mind that  
the pipes will insert slightly further into the elbows when cement  
is applied as it acts as a lubricating agent. The vertical distance  
from the bottom of the Condensate U-Assembly to the floor that  
supports the water heater should be approximately 0.25” (0.64 cm),  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
terMInatIon clearances sIdewall power vent  
POWER VENT  
(using room air for combustion)  
EXTERIOR CLEARANCES FOR SIDEWALL VENT TERMINATION  
G
V
H
D
A
E
v
L
B
v
B
B
B
V
C
B
D
E
X
I
F
E
D
CLOSED  
E
X
I
OPERABL  
F
V
M
V
V
X
CLOSED  
V
E
X
OPERABL  
V
F
B
K
J
A
VENT TERMINAL  
AIR SUPPLY INLET  
AREA WHERE TERMINAL IS NOT PERMITTED  
V
X
fIGure 15.  
Vent terminal clearances for “Power Vent” installations. Power Vent configurations use room air for combustion.  
us InstallatIons  
us InstallatIons  
Clearance above grade, veranda, porch,  
deck or balcony  
Clearance to each side of center line  
extended above meter/regulator assembly  
3 feet (91 cm) within a height 15 feet (4.5 m)  
above the meter/regulator assembly*  
12 inches (30 cm)  
a
h
I
Clearance to window or door that may  
be opened  
4 feet (1.2 m) below or to side of opening; 1  
foot (30 cm) above opening  
Clearance to service regulator vent outlet  
3 feet (91 cm)*  
B
4 feet (1.2 m) below or to side of opening;  
1 foot  
(30 cm) above opening.  
Clearance to a non mechanical air supply  
inlet into building or combustion air inlet to  
any other appliance  
Clearance to permanently closed window 12 inches (30 cm)*  
c
j
Vertical clearance to ventilated soffit  
located above the terminal within a  
horizontal distance of 2 feet (61 cm) from  
the center line of the terminal  
3 feet (91 cm) above if within  
10 feet (3 m) horizontally  
12 inches (30 cm)*  
Clearance to a mechanical air supply inlet  
d
e
K
Clearance above paved sidewalk or paved  
driveway located on public property  
7 feet (2.13 m) †  
Clearance to unventilated soffit  
12 inches (30 cm)*  
l
Clearance under veranda, porch, deck, or  
balcony  
Clearance to outside corner  
Clearance to inside corner  
2 feet (60 cm)*  
12 inches (30 cm) ‡  
f
M
18 inches (45 cm)*  
G
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code.  
† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.  
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.  
* Clearance in accordance with local installation codes and the requirements of the gas supplier and the manufacturer’s installation instructions.  
Instructions on proper installation through a sidewall are provided  
in Figure 15.  
vent pIpe terMInatIon  
The first step is to determine where the vent pipe will terminate.  
See Figures 15, 20 and 21. The vent may terminate through a  
sidewall as shown in Figure 20 or through the roof as shown  
in Figure 21.  
Plan the vent system layout so that proper clearances are  
maintained from plumbing and wiring.  
Vent pipes serving power vented appliances are classified by  
building codes as “vent connectors”. Required clearances from  
combustible materials must be provided in accordance with  
information in this manual under LOCATING THE NEW WATER  
HEATER and INSTALLING THE WATER HEATER, and with the  
National Fuel Gas Code and local codes.  
The vent system must terminate so that proper clearances are  
maintained as cited in local codes or the current edition of the  
National Fuel Gas Code, (ANSI Z223.1, 12.9.1 through 12.9.4).  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
of cracks or fractures, particularly at joints between elbows and other  
fittings and straight runs of vent pipe. Check system for signs of sagging  
or other stresses in joints as a result of misalignment of any components  
in system. If any of these conditions are found, they must be corrected in  
accordance with venting instructions in this manual before completing  
installation and putting water heater into service.  
plannInG the vent sYsteM  
Plan the route of the vent system from the discharge of the blower  
to the planned location of the vent terminal. Refer to VAA instruction  
on page 26 while planning the vent system.  
1. Layout total vent system to use a minimum of vent pipe and elbows.  
note: a. For water heaters in locations with high ambient  
temperatures (above 100°F) it is recommended that CPVC or ABS  
pipe and fittings be used. B. A 22.5 degree elbow (2” vent pipe) or a  
45 degree elbow (3” and 4” vent pipe) with an installed screen VENT  
TERMINAL must be used in all cases.  
2. This water heater is capable of venting flue gases equivalent to  
25’ (7.6 m) of 2” pipe, 65’ (19.8 m) of 3” pipe, or 128’ (39.0 m) of  
4” pipe as listed in Table 2.  
taBle 2.  
4. There will be some installations where condensate will be formed  
in the horizontal runs of the vent system. This condensate will  
run into the condensate boot attached to the blower and out the  
fitting. The water heater is shipped with condensate hose that  
attaches to the fitting on the condensate boot. No other Tee or  
fitting is required. See Figures 17, 20 and 21.  
Number of  
90° Elbows  
2” Maximum  
Pipe - ft. (m)  
3” Maximum  
Pipe - ft. (m)  
4” Maximum  
Pipe - ft. (m)  
1
2
3
4
5
6
20 (6.1)  
15 (4.6)  
10 (3.0)  
60 (18.3)  
55 (16.8)  
50 (15.2)  
45 (13.7)  
40 (12.2)  
35 (10.7)  
120 (36.6)  
112 (34.1)  
104 (31.7)  
96 (29.3)  
88 (26.8)  
80 (24.3)  
--  
--  
--  
condensate  
This water heater is a condensing unit and requires a drain to be  
locatedincloseproximitytoallowcondensatetodrainsafely. Onehose  
from blower housing, two flexible hoses from blower outlet adaptor,  
along with another flexible hose from VAAif installed, run to barb fittings  
on vent pipe assembly #2. Hose is clamped by rubber clips and flexible  
hoses by a clamp on jacket top cover. See Figure 17. Condensate  
drains from the unit at the exhaust tee located at the bottom of the unit  
(see figure 16). Condensate from this water heater is mildly acidic.  
Please note that some local codes require that condensate is treated  
by using a pH neutralizing filter prior to disposal.  
The minimum vent lengths for each of the pipe sizes is one 90°on top of  
the unit plus 2’ (61cm) of straight pipe and the appropriate termination.  
note: The equivalent feet (m) of pipe listed above are exclusive  
of the termination. That is, the termination, with an installed  
screen, is assumed to be in the system and the remainder of the  
system must not exceed the lengths discussed above.  
3. The blower discharge adapter is made to accept only straight  
sections of 2” pipe. To start, a minimum of 2 inches (5.1 cm) of 2”  
pipe must be attached to the blower discharge, see Figure 17.  
NOTE: It is important that the field supplied drain lines beyond the 1/2”  
adaptor of vent pipe assembly #1 should be installed continuously  
tilted downward toward an appropriate drain. See Figure 16. If these  
instructions are not followed or if condensate drain line is blocked, water  
will spill from condensate trap. Do not block the holes in the hex plug on  
top of a small tee in vent pipe assembly #1. As with every water heater  
installation, a drain pan should be used to prevent water damage to  
surrounding area. If necessary, a condensate pump with an incorporated  
reservoir may be used to pump water to an appropriate drain. To avoid  
condensate spillage, select a pump with an overflow switch.  
If using 2” inch vent pipe:  
A minimum of 2 inches (5.1 cm) must be attached to the blower  
before the first elbow. After the first elbow add the additional  
venting required for the installation. The total system cannot  
exceed the lengths discussed above, where each elbow is equal  
to 5 feet (1.5 m) of straight pipe.  
If using 3” or 4” inch vent pipe:  
Twoinches(5.1cm)ofpipemustbeattachedtoblowerdischargebefore  
adding a reducer to acquire desired pipe diameter. An appropriately  
sized45degreeschedule40DWVelbow(fieldsupplied)ventterminal  
must be obtained with an equivalent screen (supplied in vent kit).  
The total system cannot exceed equivalent pipe lengths discussed  
above where each elbow is equal to 5 feet (1.5 m) of straight pipe  
(3” vent pipe) or 8 feet (2.4 m) of straight pipe (4” vent pipe).  
Caution must be used to ensure that drain is free and clear of debris  
and will not allow backflow through the condensate drain line.  
Consideration must be given to avoid freezing of the condensate lines  
which could result in excessive build up of condensate inside the water  
heater. Waterproof heat tape may be required to prevent freezing of  
condensate lines. Please ensure that the outlet of condensate drain  
does not create a slippery condition which could lead to personal  
injury. Care should be taken to ensure there is no kink or twist in any  
condensate hose. If a VAA is not installed, the unused barb fitting in  
vent pipe assembly #2 should be plugged using one of the break-  
away plugs.  
note: This unit can be vented with PVC pipe materials (DWV  
ASTM-D2665 or CSA B181.2; Schedule 40, 80, 120 ASTM-D1785 or  
CSA B137.3; or SDR Series ASTM-D2241 or CSA B137.3), CPVC pipe  
materials (CPVC41 ASTM-D2846 or CSA B137.6; Schedule 40, 80  
ASTM-F441 or CSA B137.6; or SDR Series ASTM-F442), ABS pipe  
materials (Schedule 40 DWV ASTM-D2661 or CSA B181.1). Fittings,  
other than TERMINATION should be equivalent to PVC-DWV fittings  
meeting ASTM D-2665 (Use CPVC fittings, ASTM F-438 for CPVC  
pipe and ABS fittings, ASTM D-2661/3311 for ABS pipe). If CPVC or  
ABS pipe and fittings are used, then proper cement must be used for  
all joints, including joining pipe to Termination (PVC Material). If local  
codes do not allow use of PVC termination when a material other than  
PVC is used for venting, then an equivalent fitting of that material may  
be substituted if screen in PVC terminal is removed and inserted  
into new fitting.  
Breathing Hazard - Carbon Monoxide Gas  
Do NOT block the holes in the hex plug of vent pipe  
assembly #1.  
Do NOT elevate any portion of the field supplied drain  
line beyond the 1/2" adaptor above the adaptor. This  
must be true for entire length of the drain line including  
the exit into an appropriate drain  
.
Condensate lines must be free and clear of debris and  
must not allow back flow through drain line. Condensate  
lines must be able to flow freely to an appropriate drain.  
PVC Materials should use ASTM D-2564 Grade Cement; CPVC  
Materials should useASTM F-493 Grade Cement andABS Materials  
should use ASTM D-2235 Grade Cement.  
Do not allow condensate lines to become crimped closed.  
Analyze entire vent system to make sure that condensate  
will not become trapped in a section of vent pipe and  
therefore reduce open cross sectional area of vent.  
If water heater is being installed as a replacement for an existing power  
vented heater in pre-existing venting, a thorough inspection of existing  
venting system must be performed prior to any installation work. Verify  
thatcorrectmaterialasdetailedabovehasbeenused,andthatminimum  
ormaximumventlengthsandterminallocationasdetailedinthismanual  
have been met. Carefully inspect entire venting system for any signs  
Breathing carbon monoxide can cause brain damage or death.  
Always read and understand instruction manual.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The condensate trap may be primed by filling the CONDENSATE  
U-ASSEMBLY with tap water while the water heater is not operating.  
The system is fully primed when the water level reaches the adaptor  
connected into the Tee. In most installations the water heater will  
self-prime the condensate trap during the first full heat-up cycle. If  
a sound of air bubbling through water (gurgling) is heard while the  
blower is operating after the first heat-up cycle, then turn the unit off  
and contact your plumber or service representative.  
6. Make sure the ON/OFF switch is in the OFF position and that  
the outer harness is connected from the blower control box to  
the connector on the bottom side of the gas valve.  
7. If the outer harness is not factory installed, make sure the ON/  
OFF switch is in the OFF position and then connect the outer  
harness from the blower control box to the connector on the  
bottom side of the gas valve.  
If these instructions are not followed, the condensate build-up will  
block the exhaust outlet, which will cause improper operation.  
Do NOT  
block or  
plug any  
hole in this  
hex plug.  
DRAIN LINE  
CONDENSATE  
U-ASSEMBLY,  
AKA. VENT PIPE  
ASSEMBLY #1  
A
PPROXIMATELY  
0.25" (6.35 mm)  
8. Do not plug in power cord until vent system is completely installed.  
The Power Vent operates on 110-120 Vac. therefore a grounded  
outlet must be within reach of the 6 foot (1.8 m) flexible power cord  
supplied with the vent (See Figure 1). The power cord supplied  
may be used on a unit only where local codes permit. If local  
codes do not permit use of flexible power supply cord:  
*NO PORTION OF THE FIELD SUPPLIED DRAIN LINE BEYOND  
THE 1/2" ADAPTOR MAY BE ELEVATED HIGHER THAN THE  
ADAPTOR. THIS MUST BE TRUE FOR THE ENTIRE LENGTH  
OF DRAIN LINE INCLUDING EXIT INTO AN APPROPRIATE DRAIN.  
fIGure 16.  
Condensate is likely to form in the venting system attached to this  
water heater. The vent pipe should be sloped downward away from  
the blower assembly (not less than 1/8” (3.2 mm) nor greater than 1/2”  
(12.7 mm) per foot (30 cm) maximum). If the vent piping is vented level  
or sloped upwards away from the blower assembly, then adequate  
means for draining and disposing of the condensate needs to be made  
by the installer. Two 3/8” condensate hoses should be connected to  
the built in drain ports of blower outlet adaptor. If a VAA is installed,  
a 3/8” condensate hose should be connected to the barb fitting on it;  
otherwise the unused barb fitting on vent pipe assembly #2 should be  
plugged with one of the break-away plugs. See Figure 17.  
A. Make sure the unit is unplugged from the wall outlet. Remove  
the plastic top cap. Remove screws and open panel on the  
front of the control box on the blower.  
B. Cut the flexible power cord, leaving enough to be able to make  
connections. Remove the strain relief fitting from the box.  
C. Install a suitable conduit fitting inside the enclosure.  
D. Splice field wiring into existing wiring using code authorized  
method (wire nuts, etc).  
Condensate neutralizer kits are available. Contact your distributor  
or Service Agency.  
E. Be certain that neutral and line connections are not reversed  
when making these connections.  
Blower asseMBlY InstallatIon  
F. Ground heater properly. This water heater must be grounded  
in accordance with the National Electrical Code NFPA 70  
and/or local codes. These must be followed in all cases.  
1. This power vented water heater comes with blower assembly installed.  
2. After unit is set in place, make sure blower assembly is still  
mounted securely. Make sure there is no damage to blower.  
The water heater must be connected to a grounded metal,  
permanent wiring system; or an equipment grounding  
conductor must be run with the circuit conductors and  
connected to the equipment grounding terminal or lead on  
the water heater, see Figure 19.  
3. Condensate drains from three locations on blower assembly.  
See Figure 17. One flexible hose runs from bottom of blower  
housing; two run from the ports of rubber connector at the outlet  
of blower. All these three condensate hoses are connected to  
barb fittings at vent pipe assembly #2. The hose from bottom  
of blower housing is clamped by two clamps and the two hoses  
from rubber connector are harnessed by another clamp. Make  
sure there is no kink or twist.  
G. Close the panel on the control box. Make sure that the access  
panel is secured shut.  
9. Theblowerdischargebootismadetoacceptonlystraightsectionsof  
2” pipe. To start off with an elbow, a short section of the furnished  
pipe, a minimum of 2 inches (5.1 cm), must be cut and glued into  
the end of the elbow that will mount on the discharge boot.  
InstallatIon of vent sYsteM  
Before beginning installation of piping system thoroughly read the  
section of this manual VENT PIPE PREPARATION.  
If you are installing your system so that it vents through roof, please  
refer to section titled INSTALLATION OF VERTICAL VENT  
SYSTEM.  
fIGure 17.  
4. Make sure there is no packing material in the inlet or discharge  
of the blower.  
vent terMInal InstallatIon, sIdewall  
5. Make sure that the plastic tubing is still attached from the air  
pressure switch to the port on the blower housing. Make sure  
the plastic tubing is not folded anywhere between the pressure  
switch and the blower housing.  
1. Install the vent terminal by using the cover plate as a template to  
mark the hole for the vent pipe to pass through the wall. BEWARE  
OF CONCEALED WIRING AND PIPING INSIDE THE WALL.  
2. If the Vent Terminal is being installed on outside of a finished wall, it  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
may be easier to mark both the inside and outside wall. Align holes by  
drilling a hole through center of the template from the inside through to  
the outside. The template can now be positioned on the outside wall  
using the drilled hole as a centering point for the template.  
bead of caulking (not supplied) around the gap between the pipe and  
cover plate. Apply enough to fill some of the gap between the pipe  
and wall. Place some of the caulking on the back of the plate to hold it  
against the wall after installation. If the vent pipe is installed up to the  
wall, with a coupling on the end against the wall opening, the pipe with  
the vent terminal can be prepared for gluing before inserting through  
the wall. Slide the pipe through the wall and insert into the coupling on  
the other side of the wall, making sure that the vent terminal ends up  
3. A) MASONRY SIDE WALLS  
Chisel an opening approximately one half inch (1.3 cm) larger  
than the marked circle.  
pointed in the correct position, see Figure 18.  
B) WOODEN SIDE WALLS  
Drill a pilot hole approximately one quarter inch (0.64 cm) outside  
of the marked circle. This pilot hole is used as a starting point  
for a saws-all or sabre saw blade. Cut around the marked circle  
staying approximately one quarter inch (0.64 cm) outside of the  
line. (This will allow the vent to easily slide through the opening.  
The resulting gap will be covered up by the Vent Terminal cover  
plate.) Repeat this step on inside wall if necessary.  
sequence of InstallatIons, fIGure 18  
Cut a length of PVC pipe about 3.5 inches (8.9 cm) longer than wall  
thicknessattheopening. Glueventterminaltothissectionofpipe. Slide  
the wall plate over the pipe to stop against the vent terminal. Place a  
vent terMInatIon - fIGure 18.  
cautIon  
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND  
DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.  
power vent wIrInG scheMatIc - fIGure 19.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
additional vent pipe when calculating maximum equivalent  
feet of venting.  
InstallatIon of vent sYsteM, sIdewall  
With the route of the venting system and selection of materials completed,  
as discussed in the section of this manual titled PLANNING THE VENT  
SYSTEM, the through the wall vent terminal in place and the first section  
of piping, up to first elbow, installed at the blower it is time to complete the  
installation of the venting system for the sidewall installation.  
InstallatIon of vertIcal vent sYsteM  
A proper flashing or “BOOT” should be used to seal the pipe  
where it exits the roof. The total vent system should not exceed  
the equivalent feet of pipe as listed in Table 1.  
Provide support for all pipe protruding through the roof. All piping should  
be properly secured. The vent system piping should be supported  
every 5 feet (1.5 m) of vertical run and every 3 feet (91 cm) of  
horizontal run. Follow vent pipe manufacturer’s instructions for proper  
joining procedures.  
GRADE  
SNORKEL  
*MIN. 12” (30cm)  
ABOVE GRADE OR  
*MIN. 12” (30 cm)  
ABOVE  
ANTICIPATED  
SNOW LEVEL  
INSTALL A SNORKEL AS SHOWN  
HERE ONLY IF NECESSARY TO  
ACHIEVE THE 12” MINIMUM  
CLEARANCE ABOVE  
THE HIGHEST ANTICIPATED  
SNOW LEVEL.  
fIGure 21  
fIGure 20  
IMportant  
It is recommended that the completion of the venting system start  
at the blower assembly and run to the coupling on the inside wall  
of the vent terminal, Figure18.  
The vent system must terminate so that proper clearances  
are maintained as cited in local codes or the current edition  
of the National Fuel Gas Code (ANSI Z223.1) or the Natural  
Gas and Propane Installation Code (CAN/CSA-B149.1) and as  
listed below:  
The vent system piping should be supported every 5 feet (1.5 m)  
of vertical run and every 3 feet (91 cm) of horizontal run. Follow vent  
pipe manufacturer’s instructions for proper joining procedures.  
If necessary to achieve the 12” minimum clearance above  
the highest anticipated snow level, install a snorkel as shown  
in bottom portion of Figure 20.  
1. Vent Termination must extend a minimum of 12 inches (30 cm)  
above roof or 12 inches (30 cm) above the anticipated snow level  
to prevent blockage of the vent termination, as shown in Figures  
20 and 21.  
note: With the installation of a snorkel it is necessary to  
use two 90° elbows that shall be considered along with the  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Make sure the VAA and vent pipe is supported securely to  
a permanent fixture (stud or wall). Use standard support  
straps (not supplied with kit) that may be found at a local  
hardware store. Failure to properly support the VAA and the  
surrounding vent pipe could create a hazardous situation. DO  
NOT puncture any surface of the VAA.  
vent attenuatIon asseMBlY  
InstallatIon InstructIons  
The Vent Attenuation Assembly (VAA) is designed to provide a  
reduction in fan noise created in the blower wheel. This installation  
of this VAA is optional. Review directions thoroughly prior to installing  
the new VAA. Please contact the manufacturer of the water heater as  
shown in the instruction manual with any questions or for additional  
product support.  
5. Locate flexible tubing. Slide one end of tubing over the hose  
barb located near end of the VAA. The ridges on the hose  
barb should prevent the tubing from sliding off, however,  
to ensure there are no leaks and possible dislocation from  
hose barb, use a wire tie or hose clamp (not supplied with kit)  
and secure.  
vent attenuatIon asseMBlY KIt parts lIst  
The kit consists of the following items. If a part is missing, use the  
contact information in the instruction manual to acquire missing  
component(s).  
6. Take the other end of the flexible tubing and slide it through  
the hose clamp on the jacket top cover and install it into one  
of the four barb fittings in vent pipe assembly #2.  
• vent attenuation assembly  
• flexible tubing  
• instruction sheet  
7. Once installed along with the rest of the vent configuration,  
make sure to operate the unit through at least one heat up  
cycle to ensure there is no leakage around the hose barb or  
any joints of the VAA or vent pipe system.  
vent attenuatIon asseMBlY InstallatIon  
The VAA is designed for both vertical and horizontal installations.  
The vertical installation and horizontal installations will require that  
the flexible condensate hose to be attached to the condensate hose  
barb located on the bottom of the VAA to release condensate. See  
instructions and diagrams that follow for a more detailed description.  
Breathing Hazard - Carbon Monoxide Gas  
Do NOT block the holes in the hex plug of vent pipe  
assembly #1.  
Do NOT elevate any portion of the field supplied drain  
line beyond the 1/2" adaptor above the adaptor. This  
must be true for entire length of the drain line including  
fIGure 22: typical vertical Installation  
the exit into an appropriate drain  
.
Condensate lines must be free and clear of debris and  
must not allow back flow through drain line. Condensate  
lines must be able to flow freely to an appropriate drain.  
horizontal vaa Installations  
1. The VAA is designed to accept two inch PVC pipe into the  
adapters on both ends. The VAA must be installed with the  
condensate hose barb pointing downward. See Figure 23. The  
VAA has an embossed flow arrow to reflect proper orientation.  
For optimum performance, install VAA as close as possible  
to the blower assembly.  
Do not allow condensate lines to become crimped closed.  
Analyze entire vent system to make sure that condensate  
will not become trapped in a section of vent pipe and  
therefore reduce open cross sectional area of vent.  
Breathing carbon monoxide can cause brain damage or death.  
Always read and understand instruction manual.  
2. Use standard PVC cement (not included with kit) and glue the  
two inch PVC pipe coming from the blower into the VAA.  
Vertical VAA Installations (Recommended)  
3. Perform the same sequence on the PVC pipe coming from the  
1. The VAA is designed to accept two inch PVC pipe into  
the adapters on both ends. The VAA must be installed with the  
condensate hose barb pointing downward. See Figure 22. The  
VAA has an embossed flow arrow to reflect proper orientation.  
For optimum performance, install VAA as close as possible to  
the blower assembly.  
exhaust side (vent terminal side) of the VAA.  
4. Make sure the VAA and vent pipe is supported securely to a  
permanent fixture (stud or wall). Use standard support straps  
(not supplied with kit) that may be found at a local hardware  
store. Failure to properly support the VAA and the surrounding  
vent pipe could create a hazardous situation. DO NOT puncture  
any surface of theVAA.  
2. Use standard PVC cement (not included with kit) and glue the two  
inch PVC pipe coming from the blower into the VAA.  
5. Locate flexible tubing. Slide one end of tube over the hose  
barb located near end of the VAA. The ridges on the hose  
barb should prevent the tube from sliding off, however, to  
ensure there are no leaks and possible dislocation from hose  
3. Perform the same sequence on the PVC pipe coming from the  
exhaust side (vent terminal side) of the VAA.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
barb, use a wire tie or hose clamp (not supplied with kit)  
and secure.  
6. Take the other end of the flexible tubing and slide it through  
the hose clamp on the jacket top cover and install it into one  
of the four barb fittings in vent pipe assembly #2.  
7. Once installed along with the rest of the vent configuration, make  
sure to operate the unit through at least one heat up cycle to  
ensure there is no leakage around the hose barb or any joints  
of the VAA or vent pipe system.  
FIGURE 24: Typical Installation for Vertical Vent with 3 or 4 inch Pipe  
Installation of VAA with 3 & 4 inch Pipe for Horizontal Vent  
Some applications may require the use of 3 or 4 inch vent pipe for  
longer vent lengths. Please refer to the Figure 25 as you review these  
instructions. Refer back to the horizontal VAA installation steps but  
with the following changes to the vent construction.  
3 inch vent (Horizontal VAA Installations)  
The VAA is designed to accommodate only 2 inch vent pipe. The  
installer must use 2 inch vent pipe between blower assembly and inlet  
into the VAA. On the outlet side of the VAA, a short run of 2 inch vent  
pipe is required. From this point on, a 2 inch to 3 inch adapter may  
be used. From the 2 inch to 3 inch adapter, installer may use up to 52  
equivalent feet (15.8 m) of pipe. This is 8 equivalent feet (2.4 m) less  
than the original 60 equivalent feet (18.3 m) specified with one elbow  
due to the 2 inch elbow instead of a 3 inch elbow required for vent from  
fIGure 23: typical horizontal Installation  
Installation for VAA with 3 & 4 inch Pipe for Vertical Vent  
Some applications may require the use of 3 or 4 inch vent pipe for  
longer vent lengths. Please refer to Figure 24 as you review these blower to the inlet of VAA, see Figure 25 for typical installation.  
instructions. Refer back to the vertical VAA installation steps but with  
the following changes to the vent construction.  
4 inch vent (Horizontal VAA Installations)  
The VAAis designed to accommodate only 2 inch vent pipe.The installer  
must use 2 inch vent pipe between the blower assembly and the inlet into  
3 inch vent (Vertical VAA Installations)  
the VAA. On the outlet side of the VAA a short run of 2 inch vent pipe is  
The VAA is designed to accommodate only 2 inch vent pipe. The  
required. From this point on, a 2 inch to 4 inch adapter may be used. From  
installer must use 2 inch vent pipe between the blower assembly  
and the inlet into the VAA. On the outlet side of the VAA, a short  
the 2 inch to 4 inch adapter, the installer may use up to 102 equivalent feet  
(31.1 m) of pipe. This is 18 equivalent feet (5.5 m) less than the original  
run of 2 inch vent pipe is required. Each of the short pieces of 2  
inch pipe entering and exiting the VAA must not exceed 6 inches  
(15 cm) in length. From this point on, a 2 inch to 3 inch adapter  
may be used. From the 2 inch to 3 inch adapter, the installer may  
use up to 65 equivalent feet (19.8 m) of pipe, see Figure 24 for  
typical installation.  
120 equivalent feet (36.6 m) specified with one elbow due to the 2 inch  
elbow instead of a 4 inch elbow required for the vent from the blower to  
the inlet of the VAA, see Figure 25 for typical installation.  
remember to operate the unit for at least one heat cycle to ensure  
there are no air leaks in the vent joints of the vaa and the vent pipe  
system. Air leaks will allow flue gas by-products to disseminate  
into the room creating an unsafe environment and could cause  
illness, asphyxiation and/or even death.  
4 inch vent (Vertical VAA Installations)  
The VAA is designed to accommodate only 2 inch vent pipe. The  
installer must use 2 inch vent pipe between the blower assembly  
and the inlet into the VAA. On the outlet side of the VAA, a short  
run of 2 inch vent pipe is required. Each of the short pieces of 2  
inch pipe entering and exiting the VAA must not exceed 6 inches  
(15 cm) in length. From this point on, a 2 inch to 4 inch adapter  
may be used. From the 2 inch to 4 inch adapter, the installer may  
use up to 128 equivalent feet (39.0 m) of pipe, see Figure 24 for  
typical installation.  
remember to operate the unit for at least one heat cycle to  
ensure there are no air leaks in the vent joints of the vaa and  
the vent pipe system. Air leaks will allow flue gas by-products to  
disseminate into the room creating an unsafe environment and  
could cause illness, asphyxiation and/or even death.  
FIGURE 25: Typical Installation for Horizontal Vent with 3 or 4 inch Pipe  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
prIMer  
vent pIpe preparatIon  
It is recommended that Tetrahydrofuran (THF) be used to prepare the  
surfaces of pipe and fittings for solvent welding. Do not use water,  
rags, gasoline or any other substitutes for cleaning PVC or CPVC  
surfaces. A chemical cleaner such as MEK may be used.  
1. InItIal preparatIon  
A. Make sure the solvent cement you are planning to use is  
designed for the specific application you are attempting.  
ceMent  
B. Know the physical and chemical characteristics and limitations of  
the PVC and CPVC piping materials that you are about to use.  
The cement should be a bodied cement of approximately 500 to  
1600 centipoise viscosity containing 10-20% (by weight) virgin PVC  
material solvated with tetrahydrofuran (THF). Small quantities of  
dimethyl formamide (DMF) may be included to act as a retarding  
agent to extend curing time. Select the proper cement; Schedule 40  
cement should be used for Schedule 40 pipe. Never use all-purpose  
cements, commercial glues and adhesives or ABS cement to join  
PVC or CPVC pipe and fittings.  
C. Know the reputation of your manufacturer and their products.  
D. Know your own qualifications or those of your contractor. The  
solvent welding technique of joining PVC and CPVC pipe is a  
specialized skill just as any other pipe fitting technique.  
E. Closely supervise the installation and inspect the finished  
job before start-up.  
F. Contact the manufacturer, supplier, or competent consulting  
agency if you have any questions about the application or  
installation of PVC and CPVC pipe.  
G. Take the time and effort to do a professional job.  
Shortcuts will only cause you problems and delays in  
start-up. By far, the majority of failures in PVC and CPVC  
systems are the result of shortcuts and/or improper  
joining techniques.  
applIcators  
Select a suitable pure bristle type paint brush. Use a proper width  
brush or roller to apply the primer and cement (see chart below).  
Speedy application of cement is important due to its fast drying  
characteristics. IMPORTANT NOTE:Adauber type applicator should  
only be used on pipe sizes 2” and below. For larger diameter pipe,  
a brush or roller must be used.  
2. selectIon of MaterIals  
Cutting Device - Saw or Pipe Cutter  
Deburring Tool, Knife, File, or Beveling Machine (2” and above)  
Brush - Pure Bristle  
taBle 3.  
recoMMended Brush* sIZe for prIMer  
Rag - Cotton (Not Synthetic)  
and ceMent applIcatIons  
nominal pipe  
Primer and Cleaner  
size Brush width  
Solvent Cement - PVC for PVC Components and CPVC for  
CPVC Components  
(IPS)  
2
3
1.5” (3.8 cm)  
Containers - Metal or Glass to hold Primer and Cement. Select  
the type of PVC or CPVC materials to be used on the basis of  
their application with respect to chemical resistance, pressure  
rating, temperature characteristics, etc.  
1.5” - 2.5” (3.8 cm - 6.4 cm)  
*use onlY natural BrIstle  
Insertion Tool - Helpful for larger diameter pipe and fittings 6  
inches (15.2 cm) and above.  
3. MaKInG the joInt  
a. cutting  
Pipe must be squarely cut to allow for the proper interfacing of the  
pipe end and the fitting socket bottom. This can be accomplished  
with a miter box saw or wheel type cutter. Wheel type cutters are  
not generally recommended for larger diameters since they tend  
to flare the corner of the pipe end. If this type of cutter is used,  
the flare on the end must be completely removed.  
NOTE: Power saws should be specifically designed to cut plastic pipe.  
step a  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. deburring  
Use a knife, plastic pipe deburring tool, or file to remove burrs from the  
endofsmalldiameterpipe. Besuretoremoveallburrsfromaroundthe  
insideaswellastheoutsideofthepipe. Aslightchamfer(bevel)ofabout  
10°-15° should be added to the end to permit easier insertion of the pipe  
into the end of the fitting. Failure to chamfer the edge of the pipe may  
remove cement from the fitting socket, causing the joint to leak.  
step e  
f. joint assembly  
Working quickly, insert the pipe into the fitting socket bottom and  
give the pipe or fitting a 1/4 turn to evenly distribute the cement.  
Do not continue to rotate the pipe after it has hit the bottom of the  
fitting socket. A good joint will have sufficient cement to make a  
bead all the way around the outside of the fitting hub. The fitting  
will have a tendency to slide back while the cement is still wet  
so hold the joint together for about 15 seconds.  
step B  
C. Test dry fit of the joint  
Tapered fitting sockets are designed so that an interfaced fit should  
occur when the pipe is inserted about 1/3 to 2/3 of the way into the  
socket.Occasionally,whenpipettingdimensionsareatthetolerance  
extremes, it will be possible to fully insert dry pipe to the bottom of  
the fitting socket. When this happens, a sufficient quantity of cement  
must be applied to the joint to fill the gap between the pipe and fitting.  
The gap must be filled to obtain a strong, leak-free joint.  
d. Inspection, cleaning, priming  
Visually inspect the inside of the pipe and fitting sockets and remove  
alldirt, greaseormoisturewithacleandryrag. Ifwipingfailstoclean  
the surfaces, a chemical cleaner must be used. Check for possible  
damage such as splits or cracks and replace if necessary.  
depth-of-entry  
step f  
Marking the depth of entry is a way to check if the pipe has reached  
the bottom of the fitting socket in Step F. Measure the fitting depth  
and mark this distance on the pipe O.D. You may want to add  
several inches to the distance and make a second mark as the  
primer and cement will most likely destroy your first one.  
G. cleanup and joint movement  
Remove all excess cement from around the pipe and fitting  
with a dry cotton rag. This must be done while the cement is  
still soft.  
Apply primer to the surface of the pipe and fitting socket with  
a natural bristle brush. This process softens and prepares the  
PVC or CPVC for the solvent cementing step. Move quickly and  
without hesitation to the cementing procedure while the surfaces  
are still wet with primer.  
The joint should not be disturbed immediately after the cementing  
procedure, and sufficient time should be allowed for proper curing  
of the joint. Exact drying time is difficult to predict because it  
depends on variables such as temperature, humidity and cement  
integrity. For more specific information, you should contact your  
solvent cement manufacturer.  
e. application of solvent cement  
• Apply solvent cement evenly and quickly around outside of pipe  
at a width a little greater than the depth of the fitting socket.  
• Apply a light coat of cement evenly around the inside of the  
fitting socket. Avoid puddling.  
• Apply a second coat of cement to the pipe end.  
step G  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
teMperature reGulatIon  
To avoid any unintentional changes in water temperature settings, the  
control has a tamper resistant feature for changing the temperature  
setting. To change the temperature setting follow these instructions:  
It is recommended that lower water temperatures be used to avoid  
the risk of scalding. It is further recommended, in all cases, that the  
water temperature be set for the lowest temperature which satisfies  
your hot water needs. This will also provide the most energy efficient  
operation of the water heater.  
1. “Wake Up” the temperature indicators by holding down both  
“COOLER” and “HOTTER” temperature adjustment buttons at  
the same time for one second, see Figure 26. One or two of the  
temperature indicators will light up. These indicators will only  
remain on for 30 seconds if no further buttons are pressed. After  
30 seconds the control will go back to “Sleep” mode.  
Short repeated heating cycles caused by small hot water uses can  
cause temperatures at the point of use to exceed the thermostat setting  
by up to 20°F (11°C). If you experience this type of use you should  
consider using lower temperature settings to reduce scald hazards.  
2. Release both of the temperature adjustment buttons.  
a. To decrease the temperature press and release the “COOLER”  
button until the desired setting is reached.  
b. To increase the temperature press and release the “HOTTER”  
button until the desired setting is reached.  
NOTE: Holding down the button will not continue to lower or raise  
the temperature setting. The button must be pressed and released  
for each temperature change desired.  
Should overheating occur or the gas supply fail to shuttoff, turn off  
the manual gas control valve to the appliance.  
Gas control valve - front vIew  
HOT WATER CAN SCALD: Water heaters are intended to produce hot  
water. Water heated to a temperature which will satisfy space heating,  
clothes washing, dish washing, and other sanitizing needs can scald and  
permanently injure you upon contact. Some people are more likely to be  
permanently injured by hot water than others. These include the elderly,  
children, the infirm, or physically/mentally handicapped. If anyone using  
hot water from this heater fits into one of these groups or if there is a  
local code or state law requiring a certain temperature water at the  
hot water tap, then you must take special precautions. In addition  
to using the lowest possible temperature setting that satisfies your  
hot water needs, a means such as a mixing valve, should be used  
at the hot water taps used by these people or at the water heater.  
Mixing valves are available at plumbing supply or hardware stores,  
see Figure 2. Follow manufacturer’s instructions for installation of  
the valves. Before changing the factory setting on the thermostat,  
in this manual, see Figure 26.  
Never allow small children to use a hot water tap, or to draw their own  
bath water. Never leave a child or handicapped person unattended  
in a bathtub or shower.  
Time to Produce  
The water heater should be located in an area where the general  
public does not have access. If a suitable area is not available, a cover  
should be installed over the thermostat to prevent tampering.  
2nd & 3rd Degree  
Burns onAdult Skin  
About 1/2 second  
Display  
a B c  
Water Temperature  
C-Flashing = approx. 160°F (71°C)  
C = approx. 150°F (66°C)  
About 1-1/2 seconds  
Less than 5 seconds  
About 30 seconds  
The water temperature setting was factory set at the lowest temperature;  
B = approx. 140°F (60°C)  
Pressing the “COOLER”  
pressing the “HOTTER”  
button decreases temperature and  
button increases the temperature.  
A = approx. 130°F (54°C)  
= approx. 120°F (49°C)  
More than 5 minutes  
- - - - - - - - - - - - - -  
Setting water heater temperature at 120°F (49°C) (Approx. “ ” mark  
on temperature setting of gas valve) will reduce risks of scalds. Some  
states or local codes require settings at specific lower temperatures.  
WARM = approx. 80°F (27°C)  
fIGure 26.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
for Your InforMatIon  
do not remove the anode leaving the tank unprotected. By  
start up condItIons  
doing so, all warranty on the water heater tank is voided.  
sMoKe/odor  
It is not uncommon to experience a small amount of smoke and odor  
during the initial start-up. This is due to burning off of oil from metal  
parts, and will disappear in a short while.  
aIr” In hot water faucets  
stranGe sounds  
Possible noises due to expansion and contraction of some metal parts  
during periods of heat-up and cool-down do not necessarily represent  
harmful or dangerous conditions.  
Condensation causes sizzling and popping within the burner area  
during heating and cooling periods and should be considered normal.  
See “Condensate” in this manual.  
operatIonal condItIons  
HYDROGEN GAS: Hydrogen gas can be produced in a hot  
water system that has not been used for a long period of time  
(generally two weeks or more). Hydrogen gas is extremely  
flammable and explosive. To prevent the possibility of injury  
under these conditions, we recommend the hot water faucet,  
located farthest away, be opened for several minutes before any  
electrical appliances which are connected to the hot water system  
are used (such as a dishwasher or washing machine). If hydrogen  
gas is present, there will probably be an unusual sound similar to  
air escaping through the pipe as the hot water faucet is opened.  
There must be no smoking or open flame near the faucet at the  
time it is open.  
sMellY water  
In each water heater there is installed at least one anode rod for  
corrosion protection of the tank. Certain water conditions will cause a  
reaction between this rod and the water. The most common complaint  
associated with the anode rod is one of a “rotten egg smell” in the hot  
water. The smell is a result of four factors which must all be present  
for the odor to develop:  
a. A concentration of sulfate in the supply water.  
b. Little or no dissolved oxygen in the water.  
c. Asulfate reducing bacteria which has accumulated within the water  
heater (this harmless bacteria is nontoxic to humans).  
d. An excess of active hydrogen in the tank. This is caused by the  
corrosion protective action of the anode.  
hIGh water teMperature shutoff sYsteM  
This water heater is equipped with an automatic reset type high  
limit (Energy Cutoff) sensor. The high limit switch interrupts the  
main burner gas flow should the water temperature reach 195°F  
(91°C). The high limit will automatically reset when the water  
temperature drops below 140°F (60°C). After cooling the tank  
temperature, turn off the water heater for at least 10 seconds by  
using the switch on top of the unit. Turn on the water heater. If  
this fails to correct the problem, contact your plumber or service  
representative.  
Smellywatermaybeeliminatedorreducedinsomewaterheatermodels  
by replacing the anode(s) with one of less active material, and then  
chlorinating the water heater tank and all water lines. Contact the local  
water heater supplier or service agency for further information concerning  
an Anode Replacement Kit and this chlorination treatment.  
If the smelly water persists after the anode replacement and chlorination  
treatment, we can only suggest that chlorination or aeration of the water  
supply be considered to eliminate the water problem.  
perIodIc MaIntenance  
At least once a year a visual inspection should be made of the venting  
system. You should look for:  
ventInG sYsteM InspectIon  
1. Obstructions which could cause improper venting. The combustion  
and ventilation air flow must not be obstructed.  
2. Damage or deterioration which could cause improper venting or  
leakage of combustion products.  
Be sure the vent piping is properly connected to prevent escape of  
dangerous flue gasses which could cause deadly asphyxiation.  
Obstructions and deteriorated vent systems may present serious  
health risk or asphyxiation.  
Chemical vapor corrosion of the flue and vent system may occur  
if air for combustion contains certain chemical vapors. Spray can  
propellants, cleaning solvents, refrigerator and air conditioner  
refrigerants, swimming pool chemicals, calcium and sodium chloride,  
waxes, bleach and process chemicals are typical compounds which  
are potentially corrosive.  
If after inspection of the vent system you found sooting or deterioration,  
something is wrong. Call the local gas utility to correct the problem  
and clean or replace the flue and venting before resuming operation  
of the water heater.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
must be maintained. See “Locating the New Water Heater” section.  
Combustible materials such as clothing, cleaning materials, or  
flammable liquids, etc. must not be placed against or adjacent to the  
water heater which can cause a fire.  
Burner operatIon and InspectIon  
Flood damage to a water heater may not be readily visible or immediately  
detectable. However, over a period of time a flooded water heater will  
create dangerous conditions which can cause DEATH, SERIOUS  
BODILY INJURY, OR PROPERTY DAMAGE. Contact a qualified installer  
or service agency to replace a flooded water heater. Do not attempt to  
repair the unit! It must be replaced!  
anode rod InspectIon  
At least once a year a visual inspection should be made of the main burner  
and the hot surface igniter assembly for proper flame characteristics  
and ignition sequences. This can be done by removing the Outer Door  
and viewing the main burner operation through the Viewport on the  
Inner Door, see Figure 1. The main burner should provide complete  
combustion of gas, ignite rapidly, give reasonably quiet operation, and  
cause no excessive flame lifting from the burner ports. If the proper flame  
characteristics are not evident (see Figure 27), make sure that the flow  
of combustion and ventilation air is not blocked.  
Youshouldalsocheckforsooting.Sootisnotnormalandwillimpairproper  
combustion. A visual inspection of the main burner and HSI should  
also be done at least once a year, see Figure 27.  
Each water heater contains at least one anode rod, which will slowly  
deplete (due to electrolysis) prolonging the life of the water heater by  
protecting the glass-lined tank from corrosion. Adverse water quality,  
hotter water temperatures, high hot water usage, and water softening  
methods can increase the rate of anode rod depletion. Once the anode rod  
is depleted, the tank will start to corrode, eventually developing a leak.  
Soot build-up indicates a problem that requires correction before  
further use. Turn “OFF” gas to water heater and leave off until repairs  
are made, because failure to correct the cause of the sooting can result  
in a fire causing death, serious injury, or property damage.  
Certain water conditions will cause a reaction between the anode rod  
and the water. The most common complaint associated with the anode  
rod is a “rotten egg smell” produced from the presence of hydrogen  
sulfide gas dissolved in the water. IMPORTANT: Do not remove this  
rod permanently as it will void any warranties. The parts list includes a  
special anode rod that can be ordered if water odor or discoloration occurs.  
NOTE: This rod may reduce but not eliminate water odor problems. The  
water supply system may require special filtration equipment from a water  
conditioning company to successfully eliminate all water odor problems.  
fIGure 27.  
Artificially softened water is exceedingly corrosive because the process  
substitutes sodium ions for magnesium and calcium ions. The use of  
a water softener may decrease the life of the water heater tank.  
Burner cleanInG  
In the event your burner or burner air openings require cleaning, turn  
the blower switch to the “OFF” position and allow the burner to cool.  
Call a service agency to remove and clean the burner and correct the  
problem that required the burner to be cleaned.  
The anode rod should be removed from the water heater tank every  
3 years for inspection. NOTE: artificially softened water requires the  
anode rod to be inspected annually.  
The following are typical (but not all) signs of a depleted anode rod:  
* The majority of the rods diameter is less than 3/8”.  
* Significant sections of the support wire (approx. 1/3 or more of the  
anode rod’s length) are visible.  
If the anode rod show signs of either or both it should be replaced.  
houseKeepInG  
Vacuum around base of water heater for dust, dirt, and lint on a  
regular basis.  
NOTE: Whether re-installing or replacing the anode rod, check for  
any leaks and immediately correct if found.  
In replacing the anode:  
1. Turn off gas supply to the water heater.  
2. Shut off the water supply and open a nearby hot water faucet to  
depressurize the water tank.  
3. Drain approximately 5 gallons of water from tank (Refer to “Draining  
and Flushing” for proper procedures). Close drain valve.  
4. Remove old anode rod.  
5. Use Teflon® tape or approved pipe sealant on threads and install  
new anode rod.  
6. Turn on water supply and open nearby hot water faucet to purge air  
from water system. Check for any leaks and immediately correct  
any if found.  
Restart the water heater as directed under “OperatingYour Water Heater.”  
See the Repair Parts Illustration for anode rod location.  
INSTALLED IN SUITABLE AREA: To insure sufficient ventilation  
and combustion air supply, proper clearances from the water heater  
fIGure 28. anode rod depletIon.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
teMperature-pressure relIef valve test  
draInInG and flushInG  
It is recommended that the water heater storage tank be drained and  
flushed every 6 months to reduce sediment buildup. The water heater  
should be drained if being shut down during freezing temperatures.  
See Typical Installation section in this manual for location of the water  
heater components described below.  
DANGER  
Burn hazard.  
Hot water discharge.  
Keep clear of Temperature-  
Pressure Relief Valve  
discharge outlet.  
DANGER  
Burn hazard.  
Hot water discharge.  
It is recommended that theTemperature-Pressure Relief Valve should be  
checked to ensure that it is in operating condition every 6 months.  
Keep hands clear of drain  
valve discharge.  
When checking theTemperature-Pressure Relief Valve operation, make  
sure that (1) no one is in front of or around the outlet of the Temperature-  
Pressure Relief Valve discharge line, and (2) that water discharge will  
not cause any property damage, as water may be extremely hot. Use  
care when operating valve as the valve may be hot.  
to draIn the water heater storaGe tanK:  
To check the relief valve, lift lever at the end of valve several times,  
see Figure 28. The valve should seat properly and operate freely.  
1. Turn off the electrical supply to the water heater.  
2. Turn off the gas supply at the Main Gas Shutoff Valve if  
the water heater is going to be shut down for an extended  
period.  
If after manually operating the valve, it fails to completely reset and  
continues to release water, immediately close the cold water inlet to  
the water heater and drain the water heater, see DrainingAnd Flushing  
on page 32. Replace the Temperature-Pressure Relief Valve with a  
properly rated/sized new one, see Temperature-Pressure Relief Valve  
on page 15 for instructions on replacement.  
3. Ensure the cold water inlet valve is open.  
4. Open a nearby hot water faucet and let the water run until the  
water is no longer hot.  
TEMPERATURE-PRESSURE  
RELIEF VALVE  
5. Close the cold water inlet valve to the water heater.  
6. Connect a hose to the water heater drain valve and terminate  
it to an adequate drain.  
7. Open the water heater drain valve and allow all the water to  
drain from the storage tank.  
DISCHARGE PIPE  
8. Close the water heater drain valve when all water in the storage  
tank has drained.  
fIGure 28.  
If the Temperature-Pressure Relief Valve on the water heater weeps  
or discharges periodically, this may be due to thermal expansion.  
9. Close the hot water faucet opened in Step 4.  
10. If the water heater is going to be shut down for an extended  
period, the drain valve should be left open.  
Note: Excessive water pressure is the most common cause of  
Temperature-Pressure Relief Valve leakage. Excessive water system  
pressure is most often caused by “thermal expansion” in a “closed  
system.” See Closed Water Systems and Thermal Expansion on  
page 14-15. The Temperature-Pressure Relief Valve is not intended  
for the constant relief of thermal expansion.  
to flush the water heater storaGe tanK:  
11. Turn off the electrical supply to the water heater.  
12. Ensure the cold water inlet valve is open.  
Temperature-Pressure Relief Valve leakage due to pressure build  
up in a closed system that does not have a thermal expansion tank  
installed is not covered under the limited warranty. Thermal expansion  
tanks must be installed on all closed water systems.  
13. Open a nearby hot water faucet and let the water run until the  
water is no longer hot. Then close the hot water faucet.  
14. Connect a hose to the drain valve and terminate it to an  
adequate drain.  
do not pluG the teMperature-pressure relIef valve  
openInG. thIs can cause propertY daMaGe, serIous  
InjurY or death.  
15. Ensure the drain hose is secured before and during the entire  
flushing procedure. Flushing is performed with system water  
pressure applied to the water heater.  
16. Open the water heater drain valve to flush the storage tank.  
17. Flush the water heater storage tank to remove sediment and  
allow the water to flow until it runs clean.  
Explosion Hazard  
Temperature-Pressure Relief Valve  
must comply with ANSI Z21.22-  
CSA 4.4 and ASME code.  
Properly sized Temperature-Pressure  
Relief Valve must be installed in  
opening provided.  
18. Close the water heater drain valve when flushing is  
completed.  
19. Remove the drain hose.  
20. Fill the water heater - see Filling The Water Heater in this  
manual.  
Can result in overheating and  
21. Turn on electrical supply to place water heater back in  
operation.  
excessive tank pressure.  
Can cause serious injury or death.  
22. Allow the water heater to complete several heating cycles to  
ensure it is operating properly.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
servIce  
If you are not thoroughly familiar with gas codes, your water heater,  
and safety practices, contact your gas supplier or qualified installer  
If a condition persists or you are uncertain about the operation of  
the water heater contact a service agency.  
to check the water heater.  
Read this manual first. Then before checking the water heater make  
sure the gas supply has been turned “OFF”, and never turn the gas  
“ON” before the tank is completely full of water.  
Use this guide to check a “Leaking” water heater. Many suspected  
“Leakers” are not leaking tanks. Often the source of the water can  
be found and corrected.  
leaKaGe checKpoInts  
Never use this water heater unless it is completely filled with water.  
To prevent damage to the tank, the tank must be filled with water.  
Water must flow from the hot water faucet before turning “ON” gas  
to the water heater.  
B
A *Condensation may be seen on pipes in humid weather or pipe  
connections may be leaking.  
d
B. *The anode rod fitting may be leaking.  
c
C. Small amounts of water from temperature-pressure relief valve  
may be due to thermal expansion or high water pressure in your  
area.  
D. *The temperature-pressure relief valve may be leaking at the  
tank fitting.  
E. Water from a drain valve may be due to the valve being slightly  
opened.  
F. *The drain valve may be leaking at the tank fitting.  
f
G. Combustion products contain water vapor which can condense  
on the cooler surfaces of the tank. Droplets form and drip onto  
the burner or run on the floor. This is common at the time of  
start-up after installation and when incoming water is cold.  
G
e
H. Water in the water heater bottom or on the floor may be  
from condensation, loose connections, or the relief valve.  
DO NOT replace the water heater until a full inspection of  
all possible water sources is made and necessary corrective  
steps taken.  
Leakage from other appliances, water lines, or ground seepage  
should also be checked.  
*
To check where threaded portion enters tank, insert cotton  
swab between jacket opening and fitting. If cotton is wet, follow  
“Draining” instructions in the “Periodic Maintenance” section and  
then remove fitting. Put pipe dope or teflon tape on the threads  
and replace. Then follow “Filling the Water Heater” instructions  
in the “Installing the New Water Heater” section.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
repaIr parts lIst  
Key no.  
1
part description  
14  
5
15  
outer door  
2
anode  
4
3
control valve assembly  
Plastic Top  
6
4
2
13  
5
Blower assembly  
switch and harness assembly  
t&p valve  
6
7
7
8
drain valve  
9
wiring harness  
10  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
anode outlet  
vent pipe assembly #1  
vent pipe assembly #2  
vent pipe assembly #3  
Inlet Tube  
pipe nipple  
Burner tube assembly  
hot surface Igniter  
Burner head assembly  
embossed Inner door  
Insulation - Inner door  
Insulation - viewport  
window - observation  
viewport  
12  
9
3
8
Nut - Serrated Hex Flange  
screw - sheet Metal, # 8-15  
Orifice - Burner  
vent Kit assembly  
wall plate 2”  
11  
1
wall plate 3”  
18  
screen and vent terminal assembly  
Instruction tag-wire screen f/e 3”  
Instruction Tag-Wire Screen F/E 4”  
Instruction sheet  
Wire Screen 3”  
16  
17  
26  
16  
Wire Screen 4”  
Wall Plate 4”  
flexible tubing  
25  
24  
20  
Nowthatyouhavepurchasedthiswaterheater,shouldaneedeverexistfor  
repairpartsorservice,simplycontactthecompanyitwaspurchasedfromor  
direct from the manufacturer listed on the rating plate on the water heater.  
21  
23  
19  
22  
25  
Be sure to provide all pertinent facts when you call or visit.  
24  
selling prices will be furnished on request or parts will be shipped  
at prevailing prices and you will be billed accordingly.  
27  
34 35  
28  
The model number of your Gas Water Heater will be found on the  
rating place located above the gas control valve.  
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE  
FOLLOWING INFORMATION:  
32  
30  
29  
31  
33  
MODEL NUMBER  
TYPE GAS (NATURAL OR PROPANE (L.P.)  
SERIAL NUMBER  
37  
PART DESCRIPTION  
thIs Is a repaIr parts lIst, not a pacKInG lIst. parts  
are not drawn to scale.  
36  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
trouBleshootInG GuIdelInes  
trouBle shootInG  
Please check guidelines below. For your safety, water heater service should be performed only by a qualified service technician.  
Read the GENERAL SAFETY INFORMATION section first.  
INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL  
#
1
led status  
proBleM  
solutIon  
1 Ensure the wall outlet (power supply) is properly  
The gas control valve/thermostat  
has sensed inadequate or no earth  
ground.  
grounded.  
2 Ensure all ground connections/wires on the water  
heater are securely connected.  
1 Ensure the wall outlet/power supply is properly wired.  
The gas control valve/thermostat  
2
3
has sensed reversed polarity in the 2 Ensure all internal 120 VAC wiring connections and  
120 VAC power supply.  
wiring harness have no reversed wires. 120 VAC "hot"  
wire must connect to the on/off switch.  
Pressure switch circuit remaining  
closed for more than 5 seconds  
after heating cycle begins.  
1 Ensure air pressure switch circuit wiring is correct and  
the air pressure switch is not jumpered.  
Blower may not start in this  
2 Replace the air pressure switch.  
condition.  
1 Ensure the air pressure switch sensing tube is properly  
connected at both ends and is not kinked or damaged.  
2 Ensure the correct size of vent and intake air pipe (direct  
vent products) was used per the installation instructions  
in the manual that came with the water heater.  
Pressure switch circuit remains  
open longer than 5 seconds after  
the blower is energized.  
4
3 Ensure maximum number of elbows or maximum  
equivalent feet of vent or intake air pipe has not been  
exceeded per the installation instructions in the manual  
that came with the water heater.  
Blower may run continuously in  
this condition.  
4 Ensure there are no obstructions in the vent or intake air pipe.  
1 Check wiring to the hot surface igniter assembly -  
replace igniter assembly if wiring is damaged or worn.  
2 Check resistance of the igniter at igniter assembly  
plug - should be between 11 and 18 ohms at room  
temperature (77° F at plug end) - replace igniter if open  
or shorted.  
The gas control valve/thermostat  
has detected an open igniter circuit.  
5
3 Check igniter assembly plug and the socket on the gas  
control valve/thermostat for good connection.  
4 Replace igniter assembly if the plug is worn or damaged.  
5 Replace the gas control valve/thermostat if the igniter  
assembly socket on the bottom of the control is worn or  
damaged.  
1 Ensure flame sensor is making good contact with the  
burner flame and ensure flame is steady. Also ensure  
supply and manifold gas pressures are within the  
requirements in the installation manual.  
Ignition/flame failure.  
2 Gas supply is turned off - pressure is too low.  
The gas control valve/thermostat  
has reached the maximum number  
of retries (3) for ignition and is  
currently locked out for one hour.  
3 Ensure the flame sensor is clean - use fine steel wool  
to clean the flame sensor.  
6
4 Check igniter assembly plug and the socket on the  
bottom of the gas control valve/thermostat for good  
connection. Replace igniter assembly if the plug is worn  
or damaged. Replace the gas control valve/thermostat if  
socket is worn or damaged.  
Cycle the power to the water heater  
off and on to reset.  
5 Replace igniter assembly.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
#
led status  
proBleM  
solutIon  
7
8
9
1 Turn the power off for 10-20 seconds then on again to  
clear these error codes.  
Self diagnostic check has detected  
a problem with the gas valve driver  
circuit, internal microprocessor, or  
other internal circuits.  
2 If any of these error codes persist or cannot be cleared  
- replace the gas control valve/thermostat.  
1 Turn the power off for 10-20 seconds then on again to  
clear these error codes.  
The gas control valve/thermostat  
has sensed main burner flame out  
of proper sequence.  
10  
11  
12  
13  
2 Replace the gas control valve/thermostat if this error  
code persists.  
1 Turn the power off for 10-20 seconds then on again to  
clear these error codes.  
Water temperature in the tank has  
exceeded 195° F and has activated  
the ECO (energy cut off) high  
temperature limit.  
2 Replace the gas control valve/thermostat if the error  
code persists.  
1 Press and release both temperature adjust buttons  
several times - cycle water heater power off and on.  
Self diagnostic check has detected  
that one or both of the temperature  
adjust buttons are stuck.  
2 Replace the gas control valve/thermostat if the error  
code persists.  
Self diagnostic check has detected  
the water temperature sensor  
(located in the control valve's  
immersion probe) is either open or  
shorted.  
1 Turn the power off for 10-20 seconds then on again to  
clear these error codes.  
2 Replace the gas control valve/thermostat if the error  
code persists.  
1 Turn off power to the water heater. Ensure black  
resistor wire is not cut, missing, and is installed  
between pins 3 & 4 of ignitor assembly plug. Replace  
ignitor assembly if damaged or defective.  
Self diagnostic check has detected  
a problem with black resistor wire  
on the ignitor assembly plug;  
14  
resistor wire is open or shorted.  
2 Replace the gas control valve/thermostat if the error  
code persists.  
1 Turn off power to the water heater.  
Self diagnostic check has  
determined resistance of the black  
resistor wire on ignitor assembly  
plug is not within tolerance.  
2 Replace the igniter assembly plug.  
15  
3 Replace the gas control valve/thermostat if the error  
code persists.  
1 Ensure air pressure switch hose is not kinked or  
clogged, ensure the blower housing is clear of any  
condensation.  
The gas control valve/thermostat  
has detected the air pressure switch  
circuit is opening repeatedly during  
one heating cycle.  
2 Check vent temperature limit switch - if it is determined  
that the vent temperature limit switch is opening its  
contacts at normal operating temperatures during  
heating cycle - replace the vent temperature limit  
switch.  
16  
3 Ensure water heater is not over-firing. Call the technical  
support for further assistance.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
trouBleshootInG GuIdelInes  
These guidelines should be utilized by a qualified service agent.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
notes  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
lIMIted resIdentIal Gas warrantY  
b. Shipping and delivery charges for forwarding the new water heater  
THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY.  
If the glass lined tank in this water heater shall prove upon examination by (the  
warrantor)tohaveleakedduringthewarrantyperiodinnormalresidentialuse, dueto  
naturalcorrosionfrompotablewatertherein,thewarrantorwillfurnishtheORIGINAL  
OWNER a replacement water heater of equivalent size and current model, or a  
replacement part for any component part which fails in normal use, in accordance  
with the warranty terms and conditions specified below. THE WATER HEATER  
REPLACEMENT MODEL OR PART WILL BE WARRANTED FOR ONLY THE  
UNEXPIRED PORTION OF THE ORIGINAL WARRANTY. The warranty period  
will be determined by the original installation date of the water heater. PROOF-  
OF-PURCHASE AND PROOF-OF-INSTALLATION ARE NECESSARY TO  
VALIDATE THIS WARRANTY. This warranty is not transferable.  
or replacement part from the nearest distributor and returning the  
claimeddefectiveheaterorparttosuchdistributorexceptinthestateof  
California where such charges are the manufacturer’s responsibility.  
c. All cost necessary or incidental for handling and administrative  
charges, and for any materials and/or permits required for  
installation of the replacement heater or part.  
lIMItatIon on IMplIed warrantIes  
Implied warranties, including any warranty of merchantability imposed  
on the sale of this heater under state law are limited to one year  
duration for the heater or any of its parts. Some states do not allow  
limitations on how long an implied warranty lasts, so the above  
limitations may not apply to you.  
WARRANTY PERIOD  
claIM procedure  
product line  
6 50 YTVIT  
tanK1  
parts2  
6 YEARS  
6 YEARS  
laBor  
1 YEAR  
1 YEAR  
Any claim under this warranty should be initiated with the dealer who sold  
the heater, or with any other dealer handling the warrantor’s products.  
6 YEARS  
6 YEARS  
6 50 YTVIT D  
The warrantor will only honor replacement with identical or similar  
water heater or parts thereof which are manufactured or distributed  
by the warrantor.  
When the water heater has been used for other than single family  
residential application: 1. The Tank warranty shall be reduced to 3  
years on 10 year models and 1 year on 6 and 8 year models. 2. The  
parts warranty shall be reduced to 1 year for all models. Returned  
parts which meet any of the following conditions are not covered by  
this warranty: 1) improper installation or removal; 2) damaged by other  
than normal wear; 3) replaced for cosmetic purposes; or 4) returned  
with defaced date codes.  
Dealer replacements are made subject to in-warranty validation  
by warrantor.  
PROOF-OF-PURCHASE AND PROOF-OF-INSTALLATION DATES  
ARE REQUIRED TO SUPPORT WARRANTY FOR CLAIM FROM  
ORIGINAL OWNER. THIS FORM DOES NOT CONSTITUTE PROOF-  
OF-PURCHASE OR PROOF-OF-INSTALLATION.  
condItIons and eXceptIons  
This warranty shall apply only when the water heater is installed and  
operated in accordance with: 1) all local fire codes and plumbing codes,  
ordinances and regulations; 2) the printed instructions provided with it;  
3) good industry practices; and 4) proper safety practices such as but  
not limited to a properly sized drain pan if installed in an area where  
leakage from connections of the tank would result in damage to the area  
adjacent to the heater. In addition, a new temperature and pressure  
relief valve, certified by the Canadian Standards Association must have  
been properly installed and piped to the nearest drain.  
dIsclaIMers  
NOEXPRESSWARRANTYHASBEENORWILLBEMADEINBEHALF  
OF THE WARRANTOR WITH RESPECTTO THE MERCHANTABILITY  
OF THE HEATER OR THE INSTALLATION, OPERATION, REPAIR OR  
REPLACEMENT OF THE HEATER OR PARTS. THE WARRANTOR  
SHALL NOT BE RESPONSIBLE FOR WATER DAMAGE, LOSS OF  
USE OF THE UNIT, INCONVENIENCE, LOSS OR DAMAGE TO  
PERSONAL PROPERTY, OR OTHER CONSEQUENTIAL DAMAGE.  
THE WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF THIS  
WARRANTY OR OTHERWISE FOR DAMAGE TO ANY PERSONS  
OR PROPERTY, WHETHER DIRECT OR INDIRECT,AND WHETHER  
ARISING IN CONTRACT OR IN TORT.  
This warranty shall apply only when the heater is:  
owned by the original purchaser;  
used at temperatures not exceeding the maximum calibrated  
setting of its thermostat;  
Some states do not allow the limitation or exclusion of incidental or  
consequential damages, so the above limitation or exclusion may  
not apply to you.  
not subjected to excessive water pressure fluctuations and not  
subject to an operating pressure greater than 150 P.S.I.;  
filled with potable water, free to circulate at all times and with the  
tank free of damaging water sediment or scale deposits;  
used in a non-corrosive and non-contaminated atmosphere;  
used with factory approved anode(s) installed;  
in its original installation location;  
in the United States and its territories or possessions or Canada;  
sized in accordance with proper sizing techniques for residential  
water heaters;  
This warranty gives you specific legal rights, and you may also have other  
rights which vary from state to state. Should governmental regulations  
or industry standards prohibit the Manufacturer from furnishing a  
comparable model replacement under this warranty, the Owner will be  
furnished with the closest comparable water heater meeting the current  
governmental regulations and industry standards. A supplementary fee  
may be assessed to cover the additional cost associated with the changes  
made to meet applicable regulations and standards.  
bearing a rating plate which has not been altered, defaced or  
removed except as required by the warrantor;  
used in an open system or in a closed system with a properly  
sized and installed thermal expansion tank;  
fired at the factory rated input using the fuel stated in the face of  
the rating plate;  
Fill out and keep with water heater.  
IMportant InforMatIon  
operated with inner and outer combustion chamber doors in place;  
maintained in accordance with the instructions printed in the  
manual included with the heater.  
Model Number____________________________________________  
Serial Number_____________________________________________  
Installation Information:  
Any accident to the water heater or any part thereof (including freezing,  
fire, floods, or lightning), any misuse, abuse or alteration of it, any  
operation of it in a modified form, or any attempt to repair tank leaks  
or parts, will void this warranty.  
Date Installed ____________________________________________  
Company’s Name _________________________________________  
Street or P.O. Box _________________________________________  
City, State, and Zip Code ___________________________________  
Phone Number _______________Plumber’s Name_______________  
servIce and laBor responsIBIlItY  
UNDER THIS LIMITED WARRANTY, THE WARRANTOR WILL  
PROVIDE ONLY A REPLACEMENT WATER HEATER OR PART  
THEREOF. THEOWNERISRESPONSIBLEFORALLOTHERCOSTS.  
Such costs may include but are not limited to:  
a. Labor charges for service, removal, or reinstallation of the water  
heater or part thereof.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
500 Tennessee Waltz Parkway  
Ashland City, TN 37015  
Technical Support 800-365-4054  
Parts 800-821-2017  
Copyright © 2010 Reliance Water Heater Company. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

PYLE Audio Speaker PLMR44 User Guide
PYLE Audio Stereo System PLCD82MP User Guide
Radio Shack Cordless Telephone ET 596 User Guide
RCA Flat Panel Television 46LB330B5 User Guide
RCA Satellite TV System DRD455RH User Guide
Roksan Audio Stereo System Caspian FM TUNER User Guide
Rotel Stereo Receiver RX 940AX User Guide
Russell Hobbs Freezer RHCF150 User Guide
Samsung Telephone SPH m50 User Guide
Sennheiser Headphones HD 205 User Guide