Regency Wraps Indoor Fireplace P36 LPG4 User Guide

Owners &  
Installation  
P36 Gas Log Fireplace  
Models: P36-NG4  
P36-LPG4  
PLEASE KEEP THESE INSTRUCTIONS  
FOR FUTURE REFERENCE  
WARNING:  
FOR YOUR SAFETY  
Improperinstallation,adjustment,alteration,  
What to do if you smell gas:  
service or maintenance can cause injury or  
Do not try to light any  
property damage. Refer to this manual. For  
appliance  
assistanceoradditionalinformationconsult  
Do not touch any electrical  
an authorised installer, service agency or  
switch: do not use any  
phone in your building.  
LISTINGS AND CODE APPROVALS  
the gas supplier.  
Immediately call your gas  
FOR YOUR SAFETY  
Do not store or use gasoline or other  
flammablevapoursandliquidsinthevicinity  
of this or any other appliance.  
Installation and service must be performed  
by an authorised installer, service agency or  
the gas supplier.  
These gas appliances have been tested in  
accordancewithAS4553-2000,NZS5262  
and have been certified by the Australian  
Gas Association for installation and  
operationasdescribedintheseInstallation  
and Operating Instructions.  
supplierfromaneighbour's  
phone. Follow the gas  
supplier's instructions.  
If you cannot reach your  
gas supplier, call the fire  
department.  
Your unit should be serviced annually  
by an authorised service person.  
918-538b  
Download from Www.Somanuals.com. All Manuals Search And Download.  
08/16/07  
TABLE OF CONTENTS  
OPERATING INSTRUCTIONS  
DATA BADGE  
Optional Fan................................................................30  
Operating Instructions .................................................30  
Normal Operating Sounds Of Gas Appliances............31  
Shutdown Procedure...................................................31  
Data Badge ...................................................................4  
INSTALLATION  
First Fire ......................................................................31  
Lighting Procedure ......................................................31  
Copy Of The Lighting Plate Instructions......................32  
Important Message........................................................5  
Before You Start ............................................................5  
General Safety Information ...........................................5  
Installation Checklist......................................................5  
Clearances ....................................................................6  
Locating Your Gas fireplace ..........................................6  
Manufactured Mobile Home Additional Requirements ..6  
Combustible Mantels.....................................................7  
Mantel Leg Clearances .................................................8  
Framing And Finishing...................................................8  
Unit Assembly Prior to Installation.................................9  
Flueing Introduction.......................................................9  
Exterior Flue Termination Locations ............................10  
Flueing.........................................................................11  
Simpson Dura-Vent Flueing ........................................12  
Simpson Dura-Vent Flueing Components List ............12  
Flueing Arrangements - Horizontal Terminations.........13  
Flueing Arrangements - Horizontal Terminations.........14  
Flueing Arrangements - Vertical Terminations.............15  
Horizontal Terminations..............................................17  
Vertical Terminations ...................................................18  
Gas Line Installation....................................................20  
Pilot Adjustment...........................................................20  
Aeration Adjustment ....................................................20  
Gas Pipe Pressure Testing..........................................20  
Optional Brick Panels..................................................21  
Log Set Installation......................................................21  
Standard Flush Door ...................................................23  
Premium Flush Front Installation.................................24  
Option 1: Wall Switch ..................................................27  
Option 2: Remote Control............................................27  
Option 3: Wall Thermostat ..........................................27  
Thermostat Wire Table ................................................27  
Wiring ..........................................................................28  
MAINTENANCE  
Maintenance Instructions ............................................32  
Gold-Plated & Brass Louvres or Trim..........................33  
Log Replacement ........................................................33  
Thermopile / Thermocouple.........................................33  
Glass Gasket...............................................................33  
Door Glass ..................................................................33  
Removing Valve...........................................................34  
Installing Valve.............................................................34  
PARTS LIST  
Main Assembly ............................................................35  
Burner Assembly & Log Set ........................................36  
Bay Front Assembly ....................................................37  
Flush Front Accessories..............................................38  
Premium Flush Front Assembly ..................................39  
Cast Faceplate Assembly............................................40  
WARRANTY  
Warranty......................................................................43  
Regency® P36-4 Gas Log Fireplace  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DATA BADGE  
This is a copy of the label that accompanies Thelabelislocatedonthefrontinsidebaseofthe  
each P36 Zero Clearance Room Sealed Gas unit, visible when the bottom louvre is open.  
Fireplace.Wehaveprintedacopyofthecontents  
DATA BADGE NOTE: Regency® units are  
constantly being improved. Check the label on  
the unit and if there is a difference, the label on  
the unit is the correct one.  
here for your review.  
(Australia Only)  
Regency® P36-4 Gas Log Fireplace  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
IMPORTANT MESSAGE  
GENERAL SAFETY  
INFORMATION  
1) The appliance shall be installed in  
accordance with the manufacturer's  
installation instructions,local gas fitting  
regulations, municipal building codes,  
water supply regulations, electrical wiring  
regulations, with AS5601-2004 (AGA  
gas installation code) NZS 5261 (New  
Zealand)  
INSTALLATION  
CHECKLIST  
SAVE THESE INSTRUCTIONS  
TheP36-NGorP36-LPGRoomSealedFireplace  
must be installed in accordance with AS5601-  
2004andNZS52615261andtheseinstructions.  
Carefully read all the instructions in this manual  
first. Consult the "authority having jurisdiction"  
to determine the need for a permit prior to  
starting the installation. It is the responsibility of  
the installer to ensure this fireplace is installed  
in compliance with manufacturer's instructions  
and all applicable codes.  
1) Locate appliance  
a) Locate Your Gas Fireplace  
b) Clearances  
c) Combustible Mantels  
d) Framing & Finishing  
2) Assemble Top Standoffs and Top Facing  
Support and Side Nailing Strips, refer to  
section"UnitAssemblyPriortoInstallation".  
(NOTE: must be done before installing unit  
into fireplace.)  
2) Installation and repair should be done  
ONLY by an authorised person.  
BEFORE YOU START  
NOTE: NOT INTENDED AS A FIREPLACE  
INSERT.  
3) THISAPPLIANCEISNOTINTENDEDASA  
FIREPLACEINSERT. DONOTCONNECT  
TO MASONARY FLUE.  
3) Installue(Refertosection"SimpsonDura-  
vent Flueing").  
4) Make gas and electrical connections. Test  
the pilot. Must be as per diagram. Refer to  
section "Pilot Adjustment."  
4) This appliance must be connected to  
the specified flue and termination cap  
to the outside of the building envelope.  
Never flue to another room or inside a  
building. Make sure that the flue is fitted  
as per Flueing instructions.  
INSTALLATION AND REPAIR SHOULD  
BE DONE BY A AUTHORISED SERVICE  
PERSON. THE APPLIANCE SHOULD BE  
INSPECTED BEFORE USE AND AT LEAST  
ANNUALLYBYANAUTHORISEDSERVICE  
PERSON. MORE FREQUENT CLEANING  
MAY BE REQUIRED DUE TO EXCESSIVE  
LINT FROM CARPETING, BEDDING  
MATERIAL, ETC. IT IS IMPERATIVE THAT  
CONTROL COMPARTMENTS, BURNERS  
AND CIRCULATING AIR PASSAGEWAYS  
OF THE APPLIANCE BE KEPT CLEAN.  
5) Installstandardandoptionalfeatures. Refer  
to the following sections:  
a. Brick Panels  
5) Inspect the flueing system annually for  
b. Log Set  
blockage and any signs of deterioration.  
c. Flush Door  
d. Premium Flush Front  
e. Bay Door  
6) Flueing terminals shall not be recessed into  
a wall or siding.  
f. Hampton® Cast Faceplate  
g. Hampton® Cast Grills  
h. Wall Switch  
7) Any safety glass removed for servicing  
must be replaced prior to operating the  
appliance.  
DUE TO HIGH TEMPERATURES, THE  
APPLIANCE SHOULD BE LOCATED OUT  
OFTRAFFICANDAWAYFROMFURNITURE  
AND DRAPERIES.  
i. Remote Control  
j. Wall Thermostat  
k. Fan  
8) To prevent injury, do not allow anyone who  
is unfamiliar with the operation to use the  
fireplace.  
6) Final check.  
WARNING: FAILURE TO INSTALL THIS  
APPLIANCECORRECTLYWILLVOIDYOUR  
WARRANTY AND MAY CAUSE A SERIOUS  
HOUSE FIRE.  
Before leaving this unit with the customer,  
the installer must ensure that the appliance is  
firing correctly and operation fully explained  
to customer.  
9) Wearglovesandsafetyglassesforprotection  
while doing required maintenance.  
CHILDREN AND ADULTS SHOULD BE  
ALERTED TO THE HAZARDS OF HIGH  
SURFACETEMPERATURES,ESPECIALLY  
THE FIREPLACE GLASS, AND SHOULD  
STAY AWAY TO AVOID BURNS OR  
CLOTHING IGNITION.  
10) Be aware of electrical wiring locations in  
walls and ceilings when cutting holes for  
termination.  
This includes:  
1) Clockingtheappliancetoensurethecorrect  
firing rate (rate noted on label 30,000 Btu/h)  
after burning appliance for 15 minutes.  
11) Under no circumstances should this  
appliancebemodified. Partsthathavetobe  
removed for servicing should be replaced  
prior to operating this appliance.  
YOUNG CHILDREN SHOULD BE  
CAREFULLY SUPERVISED WHEN THEY  
ARE IN THE SAME ROOM AS THE  
APPLIANCE.  
2) Ifrequired,adjustingtheprimaryairtoensure  
that the flame does not carbon. First allow  
the unit to burn for 15-20 min. to stabilize.  
12) Installationandanyrepairstothisappliance  
should be done by an authorised service  
person.Anauthorisedservicepersonshould  
be called to inspect this appliance annually.  
Make it a practice to have all of your gas  
appliances checked annually.  
CAUTION:Any alteration to the product that  
causes sooting or carboning that results  
in damage is not the responsibility of the  
manufacturer.  
CLOTHING OR OTHER FLAMMABLE  
MATERIAL SHOULD NOT BE PLACED ON  
OR NEAR THE APPLIANCE. DO NOT USE  
AEROSOLS IN THE VICINITY OF THIS  
APPLIANCE.  
13) Do not slam shut or strike the glass door.  
14) Under no circumstances should any solid  
fuels (wood, paper, cardboard, coal, etc.)  
be used in this appliance.  
15) The appliance area must be kept clear and  
free of combustible materials, (gases and  
other flammable vapours and liquids).  
Regency® P36-4 Gas Log Fireplace  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
NOTE: The minimum floor clearance must  
be maintained from the top surface of the  
carpeting, tile, etc.  
LOCATING YOUR  
GAS FIREPLACE  
1) When selecting a location for your stove,  
ensure that the clearances outlined on this  
page are met.  
MANUFACTURED  
MOBILE HOME  
ADDITIONAL  
Minimum Clearance from Top of Unit to:  
Mantel* Minimum  
Ceiling from top of unit.  
7"  
(177mm)  
REQUIREMENTS  
32" (1016mm)  
1) Ensure that structural members are not cut  
Side Wall Clearance  
Bay or Flush Front  
2) Provide adequate clearances for  
or weakened during installation.  
6"  
2"  
(152mm)  
(51mm)  
servicing.  
2) Ensurepropergroundingusingthe#8ground  
Horizontal Flue Clearances  
3) The appliance must be installed on a flat,  
solid, continuous surface (e.g. wood, metal,  
concrete).Thismaybetheoor,orraisedup  
on a platform to enhance its visual impact.  
If the appliance is going to be installed  
on carpeting, combustible linoleum tile or  
other combustible material other than wood  
flooring, the appliance must be installed on  
a metal or wood panel extending the full  
width and depth of the appliance.  
lug provided. See section "Wiring."  
Top  
Side  
Bottom  
1-1/2" (38mm)  
1-1/2" (38mm)  
CLEARANCES  
The clearances listed below are Minimum  
distances unless otherwise stated:  
Vertical Flue Clearances  
1-1/4" (32mm)  
Alcove Clearances**:  
Max. Depth  
Min. Width  
Min. Height  
36" (914mm)  
48" 1219mm)  
72" 1829mm)  
A major cause of chimney related fires is  
failure to maintain required clearances (air  
space) to combustible materials. It is of the  
greatest importance that this fireplace and  
flue system be installed only in accordance  
with these instructions.  
4) The P36 Co Axial Flue Gas Fireplace can  
beinstalledinarecessedpositionorframed  
out into the room as in A, B, C, D. See  
Diagram 1.  
* see mantle clearance instructions  
(Refer to section "Combustible Mantels" &  
"Mantel Leg Clearances."  
Clearance to Combustibles from:  
WARNING  
Back  
Side  
0"  
0"  
0"  
(0mm)  
(0mm)  
(0mm)  
Fire hazard is an  
extreme risk  
Floor  
if these clearances  
are not adhered to.  
Diagram 1  
A) Flat on Wall  
B) Flat on Wall Corner  
C) Recessed into Wall/Alcove  
D) Corner  
5) This appliance is Listed for bedroom  
installationswhenusedwithaListedMillivolt  
Thermostat. Some areas may have further  
requirements, check local codes before  
installation.  
Clearances for Bay or Flush Front  
6) The P36 Co Axial Flue Gas Fireplace is  
approved for alcove installations, which  
meet the clearances listed on this page.  
7) Werecommendthatyouplanyourinstallation  
on paper using exact measurements for  
clearances and floor protection before  
actually installing this appliance. Have an  
authorized inspector, dealer, or installer  
review your plans before installation.  
Note: For flue terminations see section  
"Exterior Flue Termination  
Locations."  
Regency® P36-4 Gas Log Fireplace  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Regency® P36-4 Gas Log Fireplace  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
2) Frame in the enclosure for the unit with  
MANTEL LEG  
CLEARANCES  
framing material.  
Combustible mantel leg clearances as per  
diagram below:  
152mm SideWall  
P36  
Fireplace  
Maximum  
38mm  
projection  
51mm  
at 51mm  
minimum  
clearance.  
127mm  
Allowablemantelleg  
projection.  
Standard Framing Dimensions  
A
B
C
D
FRAMING AND  
FINISHING  
Note: 40-1/2" (1029mm) is the minimum  
height for both flex termination or  
Simpson Dura-Vent flueing.  
36-1/4" 36-1/4" 12-3/4" 46"*  
921mm 921mm 324mm 1126mm*  
1) Determine the total thickness of facing  
material (e.g. drywall plus ceramic tiles) to  
allow the finished surface to be flush with  
the front of the unit. Total facing thickness  
canvaryfrom1/2"(13mm)to1-1/4"(32mm)  
thick.  
Framing Dimensions with  
Premium Flush Front Option  
Note: The unit does not have to be  
completely enclosed in a chase. The  
clearance on top of the unit is 0" to  
thestandoffssocombustiblebuilding  
materials can be laid directly on top  
of the standoffs. You must maintain  
1-1/2" (38mm) clearance from the  
flue to combustible materials for flex  
(1-1/4" for Simpson Dura-Vent ).  
A
B
C
D
37-1/4" 37-1/4" 17-3/8" 46-1/2"*  
944mm 946mm 432mm 1182mm*  
* 'D' is Minimum height to combustible mate-  
rials including the Minimum 2" (51mm) Top  
clearance to the Horizontal Flue, see flue  
clearances in section "Clearances."  
5) Use steel studs for framing where the  
1-1/2" (38mm) clearance from the flue to  
combustiblematerialcannotbemaintained,  
e.g. front top header.  
Premium Flush Front Framing  
Do not use combustible material as lining (eg.  
timber) around the fireplace as shown in the  
shaded area in the diagram below.  
Install Side Nailing Strips, Top Facing  
Support, and Top Standoffs before  
unit is slipped into position. See "Unit  
Assembly Prior to Installation" section  
for assembly details.  
3) For exterior walls, insulate the enclosure to  
the same degree as the rest of the house,  
apply vapour barrier and drywall, as per  
local installation codes. (Do not insulate  
the fireplace itself.)  
NOTE:  
When using the Premium Flush Front  
option, a finishing trim (962mm cover)  
needs to be installed to cover the  
spacers.  
4) The top of the unit must not be closer than  
32" (813mm) to the ceiling.  
Maintain a physical gap between lining  
and spacers 2-5mm. (5mm clearance to  
framing each side).  
Regency® P36-4 Gas Log Fireplace  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
1) Mount Top Facing Support using the 3  
supplied screws into the three pre-punched  
screw holes on the top front of the unit. Use  
hole positionsA, B, or C depending on your  
facing depth.  
Premium Flush Front  
Spacer Installation  
UNIT ASSEMBLY  
PRIOR TO  
Beforetheunitisslidintoposition,installthe  
provided spacers to the side of the fireplace  
as follows;  
INSTALLATION  
TheTop Facing Support, the Side Nailing Strips  
and the 2 Top Standoffs must be correctly  
positioned and attached to the top before unit  
is slipped into position.  
1) Align the screw locations on spacer with  
screw locations on the side of the firebox  
and secure in place using 3 screws.  
Top Standoff Assembly  
2) Repeat for other side.  
The top standoffs are shipped in a flat position  
and must be folded into shape and attached.  
NOTE: The side nailing strips are to be in-  
stalled to the spacer after the spacer  
is attached to the unit.  
1) Remove the standoffs from the fireplace  
top.  
2) Takeeachstandoffandbendintothecorrect  
shape. Bend up at the bend lines until the  
screw holes in the standoff and the pre-  
punched screw holes on the fireplace top  
line up.  
3) Attachthestandoffsecurelytothetopwith2  
screws per standoff (on opposite corners).  
Spacer  
"C" Screw Position:  
For a facing material depth of 1-1/4"  
(32mm), the top facing support must be  
reversed.  
Left Side Shown  
Top Facing Support and  
Side Nailing Strips  
FLUEING  
INTRODUCTION  
Determine the total thickness of facing material  
(e.g. drywall plus ceramic tiles) to allow the  
finished surface to be flush with the front of the  
unit. Total facing thickness can vary from 1/2"  
(13mm) to 1-1/4" (32mm) thick.  
The P36 uses the "balanced flue" technology  
Co Axial system. The inner liner flues products  
of combustion to the outside while the outer  
liner draws outside combustion air into the  
combustion chamber thereby eliminating the  
needtouseheatedroomairforcombustionand  
losing warm room air up the chimney.  
2) Use the same screw hole position for the  
Side Nailing Strips as was used for the Top  
Facing Support. Attach each side nailing  
strip using 3 screws.  
TheTopFacingSupport&SideNailingStripscan  
be mounted in 3 different positions depending  
on the thickness of the facing material.  
Note: These flue pipes must not be  
connected to any other appliance.  
Screw  
Position  
Facing Material  
Depth  
The gas appliance and flue system must be  
flued directly to the outside of the building,  
and never be attached to a chimney serving a  
separate solid fuel or gas burning appliance.  
Each Co Axial Flue gas appliance must use  
it's own separate flue system. Common flue  
systems are prohibited.  
A
1/2"  
/ 13mm  
/ 22mm  
/ 32mm  
B
7/8"  
C*  
1-1/4"  
* For "C" screw position the top facing support  
is reversed.  
Regency® P36-4 Gas Log Fireplace  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
EXTERIOR FLUE TERMINATION LOCATIONS  
Minimum clearances required for balanced flue terminals or  
the flue terminals of outdoor appliances  
according to AS5601-2004 (AGA gas installation code) or NZS 5261 (New Zealand)  
Minimum  
Clearance (mm)  
a
Below eaves, balconies or other projections:  
- Appliances up to 50 MJ/h input  
300  
500  
300  
500  
1000  
500  
150  
- Appliances over 50 MJ/h input  
b
c
d
e
f
From the ground or above a balcony  
From a return wall or external corner  
From a gas meter (M)  
From an electricity meter or fuse box (P)  
From a drain or soil pipe  
g
Horizontal from any building structure (unless appliance is approved  
for closer installation) or obstruction facing a terminal  
From any other flue terminal, cowl or combustion air intake  
Horizontally from an openable window, door, or non-mechanical air inlet, or  
any other opening into a building, with the exception of sub-floor ventilation  
(see also Note (I)):  
500  
500  
h
j
- Appliances up to 150 MJ/h input  
- Appliances over 150 MJ/h input  
500  
1500  
k
Vertically below an openable window, door, or non-mechanical air inlet,  
or any other opening into a building, with the exception of sub-floor ventilation  
(see also Note (I)): see table below  
Clearance 'k' in mm  
Space Heaters  
Up to 50 MJ/h  
input  
All Other Appliances  
Up to 50 MJ/h input Over 50 MJ/h input Over 150 MJ/h input  
to 150 MJ/h input  
150  
500  
1000  
1500  
NOTES:  
(I) For mechanical air inlets, including spa blowers, the clearance 'j' and 'k' shall be 1500 mm in all cases.  
(II) All distances shall be measured vertically or horizontally along the wall to a point in line with the nearest par to of the terminal.  
(III) Prohibited area below electricity meter or fuse box extends to ground level.  
(IV)A flue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and a free flow  
of air at the appliance is achieved.  
Regency® P36-4 Gas Log Fireplace  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FLUEING  
Regency® Direct Vent System (Flex)  
Horizontal Terminations Only  
These flueing systems, in combination with the P36 Room Sealed Gas Fireplace, have been tested and listed as a Direct Vent type flue system  
by the Australian Gas Association. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram in  
section "Exterior Flue Termination Locations."  
Regency® Direct Vent (Flex) System Termination Kit (Part # 946-515) includes all the parts needed to install the P36 with a maximum run  
of 1200mm.  
1) 175mm dia. flexible liner (1200mm length)  
2) 100mm dia. flexible liner (1200mm length)  
3) spring spacers (4)  
4) thimble (2)  
Wall Thimble  
5) AstroCap termination cap (1)  
6) screws (12)  
7) tube of Mill Pac (1)  
8) plated screws (8)  
9) screws #8 x 1-1/2" Drill Point, Stainless  
Steel (4)  
AstroCap  
Termination Cap  
(Part# 946-578/P)  
(patented)  
4" (102mm)  
dia. flue pipe  
If longer runs are needed, the Regency® Direct  
Vent system (Flex) # 946-516 includes all the  
parts needed to install the P36 with a maximum  
3.0m run.  
6-7/8"  
(173mm)  
dia. Flue pipe  
spring spacer  
1) 175mm dia. flexible liner (3.0m length)  
2) 100mm dia. flexible liner (3.0m length)  
3) spring spacers (7)  
4) thimble (2)  
5) AstroCap termination cap (1)  
6) screws (12)  
7) tube of Mill Pac (1)  
8) plated screws (8)  
9) screws #8 x 1-1/2" Drill Point, Stainless  
Steel (4)  
Notes:  
1) Liner sections should be continuous without any joints or seams.  
2) Only Flex pipe purchased from Regency® may be used for Flex installations.  
3) If you are installing the P36 into a Regency® Mantel Kit, use the minimum horizontal vent height (centre-line of 1029mm). Remember  
to include the mantel base in your calculations and to maintain the 32mm clearance (38mm with Flex) to the underside of the mantel  
top.  
Regency® P36-4 Gas Log Fireplace  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
SIMPSON DURA-VENT FLUEING  
Horizontal or Vertical Terminations  
The Simpson Dura-Vent Co Axial Flue System offers a complete line of component parts for installation of both horizontal and vertical installations.  
Many items are offered in decorative black, as well as galvanized finish. We recommend using the galvanized finish for installation with the P36.  
The minimum components required for a basic  
horizontal termination are:  
If a Vinyl Siding Standoff is required (it must  
be used with vinyl siding), measure to outside  
surface of wall without siding and add 2  
inches.  
Wall thickness is measured from the back  
standoffs to the inside mounting surface of  
terminationcap.Forsidingotherthanvinylfurring  
strips may be used, instead of the vinyl siding  
standoff, to create a level surface to mount the  
flueterminal.TheTerminalmustnotberecessed  
intosiding.Measurethewallthicknessincluding  
furring strips.  
1
1
1
1
1
Horizontal Termination Cap  
90o Elbow  
Flue Adaptor  
Wall Thimble  
Length of pipe to suit wall thickness  
(see chart)  
Flat Wall Installation  
Wall Thickness  
(inches)  
Vent Length Required  
(inches)  
4" - 5-1/2"  
7" - 8-1/2"  
10" - 1-1/2"  
9" - 14-1/2"  
15" - 23-1/2"  
6"  
9"  
12"  
11" - 14-5/8" Adj. Pipe  
17" - 24" Adj.  
Corner Installation  
Wall Thickness  
(inches)  
Vent Length Required  
(inches)  
3-1/4" - 6-3/4"  
7-3/4" - 16-1/4"  
7-1/4" - 8-3/4"  
11" - 14-5/8" Adj. Pipe  
17" - 24" Adj. Pipe  
6" + 12"  
9" + 9"  
4-1/4" - 5-3/4"  
6" + 9"  
Simpson Dura-Vent  
Co-Axial Flue GS  
SIMPSON DURA-VENT FLUEING COMPONENTS LIST  
All Simpson Dura-Vent components are available directly from Regency®.  
Part # Description  
Part # Description  
Part # Description  
Horiz. Termination Kit includes: 90o  
902B 48" Pipe Length - Black  
911B 11"-14 5/8" Adjustable Pipe Length  
- Black  
940  
941  
Wall Thimble - Support/Box  
Cathedral/Ceiling - Support/Box  
971  
black elbow, wall thimble cover, horiz. square  
termination cap, 24" black pipe, and 11" -14"  
5/8" adjustable black pipe.  
3951 Brass Trim for Wall Thimble/Ceiling  
Sup.  
917B 17"- 24" Adjustable Length - Black  
45O Elbow - Galv.  
963  
943  
Firestop Spacer  
970  
Basic Horiz. Termination. Kit includes:  
90o blackelbow,wallthimblecover,horiz.  
square termination cap.  
Vert. Termination Kit includes 0/12 -  
6/12 pitch adjustable flashing, storm  
collar, low profile term. cap.  
945  
945B 45O Elbow - Black  
Flashing 0/12-6/12  
945G 45O Elbow - Swivel - Galv.  
945BG 45O Elbow - Swivel - Black  
943S Flashing 7/12-12/12  
953  
950  
988  
942  
Storm Collar  
978  
90O Elbow - Galv.  
Vinyl Siding Standoff  
Wall Strap  
990  
990B 90O Elbow - Black  
990G 90O Elbow - Swivel - Galv.  
990BG 90O Elbow - Swivel - Black  
Wall Thimble  
908B 6" Pipe Length - Black  
907B 9" Pipe Length - Black  
906  
Parts not supplied by Dura-Vent  
12" Pipe Length - Galv.  
991  
980  
984  
985  
High Wind Termination Cap (Vertical)  
Vertical Termination Cap  
946-506/P  
510-994  
640-530/P  
946-205  
Flue Guard (Optional)  
Dura-Vent Flue Adaptor  
Riser Flue Terminal  
VinylSidingShieldforRiserFlue  
Terminal  
906B 12" Pipe Length - Black  
904 24" Pipe Length - Galv.  
904B 24" Pipe Length - Black  
903 36" Pipe Length - Galv.  
Horizontal Square Termination Cap  
Horiz. Square High Wind  
Termination Cap  
Snorkel - 14" Rise Termination Cap  
Snorkel - 36" Rise Termination Cap  
903B 36" Pipe Length - Black  
982  
981  
902  
48" Pipe Length - Galv.  
Regency® P36-4 Gas Log Fireplace  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS  
SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and  
REGENCY® DIRECT VENT SYSTEM (FLEX)  
(LPG & NG)  
The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90o elbow (two 45o elbows equal  
one 90o elbow).  
Note: Must use optional flue adapter (Part # 510-994) when using Simpson Dura-Vent pipe.  
Simpson Dura-Vent  
4" (102mm) inner diameter  
6-5/8" (168mm) outer diameter  
Regency® Flex Vent  
4" (102mm) inner diameter  
6-7/8" (175mm) outer diameter  
Aflueguardshouldbeusedwhenever  
the termination is lower than the  
specified minimum or as per local  
codes.  
Note: Regency® Co Axial Flue System  
(Flex) is only approved for  
horizontal terminations.  
Maintain clearances to combustibles as listed in section "Clearances."  
Horizontal flue must be supported every 3 feet (0.9 meters).  
Firestops are required at each floor level and whenever passing through a wall.  
Regency® P36-4 Gas Log Fireplace  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS  
SIMPSON DURA-VENT DIRECT FLUE GS SYSTEM and  
REGENCY® CO AXIAL FLUE SYSTEM (FLEX)  
(LPG & NG)  
The diagram below shows examples of horizontal termination arrangements using two 90o elbows (two 45o elbows equal one 90o elbow).  
Note:  
1) A maximum of two 90o elbows are permitted.  
2) A minimum of 6 ft. (1.8m) vertical from base of unit is required if two 90o elbows are used.  
3) Minimum distance between elbows is 2 ft. (0.6m).  
4) Determine the permitted range of horizontal termination arrangements by using chart in section "Simpson Dura-vent  
Flueing." and deducting 3 ft. (0.9m) from the maximum horizontal distance for the second 90o elbow.  
Iflength"B"isincreased,length"A"mustbe  
decreased by a corresponding amount.  
Simpson Dura-Vent  
4" inner diameter  
6-5/8" outer diameter  
A flue guard should be used whenever the  
termination is lower than the specified minimum  
or as per local codes.  
Maintain clearances to combustibles as listed in section "Clearances."  
Horizontal flue must be supported every 3 feet (0.9 meters).  
Firestops are required at each floor level and whenever passing through a wall.  
Regency® P36-4 Gas Log Fireplace  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS  
SIMPSON DURA-VENT CO AXIAL FLUE GS SYSTEM (LPG & NG)  
The P36 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset  
using two 90o elbows (two 45o elbows equal one 90o elbow) with Simpson Dura-Vent Co Axial  
Flue GS flue systems for LPG and NG, as per diagram 1.  
The P36 is approved for a 37 ft. (11.3m) straight vertical, including a 20" (0.5m) horizontal offset  
using two 90o elbow (two 45o elbows equal one 90o elbow) with Simpson Dura-Vent Co Axial  
Flue GS flue systems for LPG and NG, as per the diagram 2.  
Flue must be supported at offsets  
Maintain clearances to combustibles as listed in section "Clearances."  
Note: Must use optional flue adapter when using Simpson Dura-Vent pipe  
(Part # 510-994).  
Note: Regency® Co Axial Flue System (Flex) is only approved for horizontal  
terminations.  
Diagram 2  
Diagram 1  
Regency® P36-4 Gas Log Fireplace  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
The P36 is approved for a 37 ft. (11.3m) straight vertical, with Simpson  
Dura-Vent Co Axial Flue GS flue systems for LPG and NG, as per the  
diagram 3.  
The shaded area in the diagram 3 shows all allowable combinations of  
straight vertical and offset to vertical terminations with Simpson Dura-  
Vent Co Axial Flue GS flue systems for LPG and NG. Maximum two  
45o elbows allowed.  
Flue must be supported at offsets  
Firestops are required at each floor level and whenever passing  
through a wall.  
Maintain clearances to combustibles as listed in section  
"Clearances."  
Diagram 3  
Regency® P36-4 Gas Log Fireplace  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
b) Horizontalrunsofuemustbesupported  
everythreefeet.Wallstrapsareavailable  
for this purpose.  
HORIZONTAL  
TERMINATIONS  
5) Markthewallfora10"x10" squarehole.The  
center of the square hole should line up with  
thecenterlineofthehorizontalpipe.Cutand  
frame the 10 inch square hole in the exterior  
wall where the flue will be terminated. If the  
wall being penetrated is constructed of non-  
combustible material, i.e. masonry block or  
concrete,a7"(178mm)dia.(7-1/2"(191mm)  
dia. for flex) hole is acceptable.  
Install the flue system according to the  
manufacturer's instructions included with  
the components.  
1) Set the unit in its desired location. Check  
to determine if wall studs or roof rafters  
are in the way when the flueing system is  
attached. If this is the case, you may want  
to adjust the location of the unit. Rough in  
the gas preferably on the right side of the  
unit and the electrical (junction block is on  
the left side) on the left.  
Diagram 3  
Note: With  
Dura-Vent,  
theminimum  
height is  
achieved by  
installing a  
90o elbow  
directlytothe  
flue adaptor.  
8) Slide the appliance and flue assembly  
towards the wall carefully inserting the  
flue pipe into the flue cap assembly. It is  
important that the flue pipe extends into  
the flue cap sufficient distance so as to  
result in a minimum pipe overlap of 1-1/4  
inches. Securetheconnectionbetweenthe  
flue pipe and the flue cap by attaching the  
two sheet metal strips extending from the  
flue cap assembly into the outer wall of the  
flue pipe. Use the two sheet metal screws  
provided to connect the strips to the pipe  
section. See Diagram 4.  
2) CoAxial Flue pipe and fittings are designed  
with special twist-lock connections to  
connect the flueing system to the appliance  
flue outlet. A twist-lock appliance adaptor  
is an available option that must be used in  
conjunctionwiththeSimpsonDura-VentCo  
Axial Flue GS system.  
3) Put a bead of silicone inside the outer  
section of the adapter and a bead of Stove  
Mate on the inner collar. Slip the adapter  
over the existing inner and outer flue collar  
and fasten to the outer collar only with the  
3 supplied screws (drilling pilot holes will  
make this easier). Level the fireplace and  
fasten it to the framing using nails or screws  
through the nailing strips.  
Diagram 2  
Note:  
9) Install wall thimble in the center of the  
10" square and attach with wood screws  
(Diagram 5).  
a) The horizontal run of flue must be level,  
or have a 1/4 inch rise for every 1 foot  
of run towards the termination. Never  
allow the flue to run downward. This  
couldcausehightemperaturesandmay  
present the possibility of a fire.  
4) Assemble the desired combination of pipe  
and elbows to the appliance adaptor and  
twist-lock for a solid connection.  
Note:  
b) The location of the horizontal flue  
terminationonanexteriorwallmustmeet  
all local and national building codes,  
and must not be blocked or obstructed.  
For External Flue Terminal Locations,  
see diagram in section "Exterior Flue  
Termination Locations."  
a) Twist-lockprocedure:Fourindentations,  
locatedon thefemaleendsofpipesand  
fittings, are designed to slide straight  
onto the male ends of adjacent pipes  
and fittings, by orienting the four pipe  
indentations so they match and slide  
in to the four entry slots on the male  
ends,Diagram1.Pushthepipesections  
completely together, then twist-lock  
one section clockwise approximately  
one-quarter turn, until the two sections  
arefullylocked.Thefemalelockinglugs  
will not be visible from the outside, on  
the Black Pipe or fittings. They may be  
located by examining the inside of the  
female ends.  
6) The arrow on the flue cap should  
be pointing up. Insure that the 1-1/2"  
clearances to combustible materials are  
maintained. Install the termination cap,  
diagram 5.  
Diagram 4  
The four wood screws provided should  
be replaced with appropriate fasteners for  
stucco, brick, concrete, or other types of  
sidings.  
Note: If installing termination on a siding  
covered wall, a vinyl siding standoff  
or furring strips must be used to  
ensure that the termination is not  
recessed into the siding.  
Diagram 1  
7) Before connecting the horizontal run of  
flue pipe to the flue termination, slide the  
Wall Thimble (Part # 620-926) over the flue  
pipe.  
Diagram 5  
Note: Applysealant"Mill-Pac"toinnerpipe  
andhightemperaturesiliconesealant  
to outer pipe on every  
twist-lock joint.  
Regency® P36-4 Gas Log Fireplace  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
VERTICAL  
Roof Pitch  
Minimum Flue Height  
Feet  
2
2
Meters  
0.61  
0.61  
0.61  
0.76  
0.99  
1.22  
1.52  
1.83  
2.13  
2.29  
2.44  
TERMINATIONS  
flat to 7/12  
1) Maintain the 1-1/4"  
clearances (air spaces)  
to combustibles when  
passing through ceilings,  
walls, roofs, enclosures,  
attic rafter, or other nearby  
combustible surfaces.  
Do not pack air spaces  
with insulation. Check  
section "Simpson Dura-  
vent Flueing" for the  
maximum vertical rise of  
the flueing system and the  
maximum horizontal offset  
limitations.  
over 7/12 to 8/12  
over 8/12 to 9/12  
over 9/12 to 10/12  
over 10/12 to 11/12  
over 11/12 to 12/12  
over 12/12 to 14/12  
over 14/12 to 16/12  
over 16/12 to 18/12  
over 18/12 to 20/12  
over 20/12 to 21/12  
2
2.5  
3.25  
4
5
6
7
7.5  
8
Diagram 3  
4) Assemble the desired lengths of pipe and  
elbows. Ensure that all pipes and elbow  
connections are in the fully twist-locked  
position and sealed.  
Galvanizedpipeisdesirableabovetheroofline  
duetoitshighercorrosionresistance.Continue  
to add pipe sections through the flashing until  
the height of the flue cap meets the minimum  
heightrequirementsspecifiedinDiagram5or  
local codes. Note that for steep roof pitches,  
the vertical height must be increased. A poor  
draft, or down drafting can result from high  
wind conditions near big trees or adjoining  
roof lines, in these cases, increasing the flue  
height may solve the problem.  
5) Cut a hole in the roof centered on the small  
drilled hole placed in the roof in Step 2. The  
hole should be of sufficient size to meet  
the minimum requirements for clearance  
to combustibles of 1-1/2". Slip the flashing  
undertheshingles(shinglesshouldoverlap  
half the flashing) as per Diagram 4.  
Diagram 1  
2) Setthegasapplianceinitsdesiredlocation.  
Dropaplumbbobdownfromtheceilingtothe  
position of the appliance flue exit, and mark  
the location where the flue will penetrate  
the ceiling. Drill  
a small hole at  
his point. Next,  
drop a plumb  
bob from the  
7) Ensure flue is vertical and secure the base  
of the flashing to the roof with roofing rails,  
slide storm collar over the pipe section and  
seal with a mastic.  
roof to the hole  
previouslydrilled  
in the ceiling,  
and mark the  
spot where  
8) Install the vertical termination cap by twist-  
the flue will  
locking it.  
penetrate the  
roof. Determine  
Note: Anyclosetsorstoragespaces,which  
the flue passes through must be  
enclosed.  
if ceiling joists,  
roof rafters or  
other framing  
will obstruct the  
Diagram 4: The upper half of the flashing is  
installed under the roofing material and not  
nailed down until the chimney is installed.  
This allows for small adjustments.  
Diagram 2  
flueing system. You  
may wish to relocate the appliance or to  
offset,asshowninDiagram2toavoidcutting  
load bearing members.  
Offset Chart  
6) Continue to assemble pipe lengths.  
Note: If an offset is necessary in the attic  
to avoid obstructions, it is important  
to support the flue pipe every 3 feet,  
to avoid excessive stress on the  
elbows, and possible separation.  
Wall straps are available for this  
purpose (Diagram 2).  
Note: Apply sealant "Mill-Pac" to inner  
pipe and high temperature silicone  
sealant to outer pipe on every twist-  
lock joint.  
3) A Firestop spacer must be installed in the  
floor or ceiling of every level. To install the  
Firestop spacer in a flat ceiling or wall,  
cut a 10 inch square hole. Frame the hole  
as shown in Diagram 3 and install the  
firestop.  
Diagram 5  
Regency® P36-4 Gas Log Fireplace  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Conversion Kit #513-968 from NG to LPG  
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!  
8) Remove burner orifice with a 1/2" wrench.  
WARNING!  
Do not over tighten the screw.  
Recommended to  
Conversion Kit Contains:  
Use another wrench to hold on to the elbow  
behind the orifice. Discard orifice.  
Qty.  
Part #  
Description  
1
910-037  
LPG Injector  
(Pilot Orifice)  
grip the wrench by the short side.  
1
1
904-390  
918-590  
Burner Orifice #52  
Decal "Converted  
to LPG"  
16) Verify that if the conversion is from NG to  
LPG, the screw must be re-assembled with  
the red o-ring visible (Fig. 5).  
1
1
1
908-528  
904-529  
918-546  
Red "LPG" label  
5/32" Allen Key  
Instruction Sheet  
LPG Configuration  
Red o-ring visible  
1) Shut off the gas supply.  
Burner Orifice  
2) Remove the louvers (and bay door if it is  
installed).  
9) Reinstall new burner orifice LPG stamped  
#52 and tighten.  
3) Open the flush door and remove the door.  
4) Remove the logs and embers (if used).  
5) Remove the 2 screws holding the Burner  
10) Turn control knob to the “OFF” position.  
Fig.5  
11) Remove the black  
protection cap by hand  
from the hi-low knob  
(Fig.1).  
Assembly to the firebox base. Push the  
Burner Assembly to the left and lift out.  
17) Re-assemble the  
black protection cap  
(Fig. 6).  
18) Reverse step 2).  
Fig. 1  
Fig. 6  
12) Inserta5/32or4mmAllen  
wrenchintothehexagonal  
key-way of the screw  
(Fig. 2), rotate it counter-  
clockwiseuntilitisfreeand  
extract it.  
Remove the 2 screws, push Burner Assembly  
to the left and lift out.  
WARNING!  
Also check that the pilot and main  
burner injectors are appropriate for  
the gas type.  
6) Pull off the pilot cap to expose the pilot  
orifice.  
Fig.2  
13) Check that the screw is  
clean and if necessary  
remove dirt.  
19) Attach clear label "This unit has been  
converted to LPG" near or on the serial  
# decal.  
14) Flip the screw (Fig. 3).  
20) Replace yellow "NG" label with red "LPG"  
label.  
21) Check for gas leaks.  
7) Unscrew the pilot orifice with the allen key;  
then replace with the LPG pilot orifice and  
the pilot cap, provided in the kit.  
22) Check inlet and outlet pressures.  
23) Check operation of flame control.  
Fig.3  
15) Using the Allen wrench as  
shown in Fig.4, rotate the  
screwclockwiseuntilsnug,  
do not overtighten.  
24) Check for proper flame appearance and  
glow on logs.  
Fig.4  
Regency® P36-4 Gas Log Fireplace  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
GAS LINE  
PILOT ADJUSTMENT  
P36-NG System Data  
INSTALLATION  
Periodically check the pilot flames. Correct  
flame pattern has three strong blue flames:  
1 flowing around the thermopile, 1 around  
the thermocouple and 1 flowing across the  
burner (it does not have to be touching the  
burner).  
For 0 to 4500 feet altitude  
Burner Inlet Orifice Sizes: #37( 2.65mm)  
The gas line can be brought through either the  
right or the left side of the appliance. The gas  
valve is situated on the right hand side of the  
unit and the gas inlet is on the right hand side  
of the valve.  
Max. Input Rating 33 mj  
Min. Input Rating 20 mj  
Supply Pressure  
min.1.25 kPa  
Note: Ifyouhaveanincorrectamepattern,  
contact your Regency® dealer for  
further instructions.  
Note: If the gas line is being installed from  
the left side, be sure to leave room to  
accommodate servicing of the fan.  
Manifold Pressure  
(High)  
0.9 kPa  
Electrical: 240 V A.C. System.  
Circulation Fan: variable speed 130 CFM.  
Log Set: Ceramic fibre, 7 per set.  
Flue System: Simpson Dura-Vent Direct  
Flue System or Regency® Direct  
Flue System (Flex)  
The gas line connection may be made of  
rigid pipe, copper pipe or an approved flex  
connector. (If you are using rigid pipe, ensure  
that the valve can be removed for servicing.)  
Since some municipalities have additional local  
codes it is always best to consult with your local  
authorities and the AS5601-2004 or NZS 5261  
installation code.  
P36-LPG System Data  
For 0 to 2000 feet altitude  
Incorrect flame pattern will have small,  
probably yellow flames, not coming into  
proper contact with the rear burner or  
thermopile or thermocouple.  
When using copper or flex connectors use only  
approved fittings. Always provide a union so  
that gas lines can be easily disconnected for  
servicing. Flare nuts for copper lines and flex  
connectors are usually considered to meet this  
requirement.  
Burner Inlet Orifice Sizes: #52 (1.6 mm)  
Max. Input Rating 31 mj  
Min. Input Rating 18 mj  
Important:Alwayscheckforgasleakswitha  
soapandwatersolutionorgasleakdetector.  
Do not use open flame for leak testing.  
For 0 to 4500 feet Altitude:  
Supply Pressure  
min 2.75 kPa  
Manifold Pressure  
(High)  
AERATION  
2.7 kPa  
ADJUSTMENT  
GAS PIPE PRESSURE  
TESTING  
The appliance must be isolated from the gas  
supply piping system by closing its individual  
manual shut-off valve during any pressure  
testing of the gas supply piping system at  
test pressures equal to or less than 1/2 psig.  
(3.45 kPa). Disconnect piping from valve at  
pressures over 3.45 kPa.  
Electrical: 240 V A.C. System.  
Circulation Fan: variable speed 130 CFM.  
Log Set: Ceramic fibre, 7 per set.  
Flue System: Simpson Dura-Vent Co Axial  
Flue System  
The air shutter can be adjusted by moving the  
adjusting wire up or down. The wire is accessed  
throughthebottomlouvreopening.Opentheair  
shutter for a blue flame or close for a yellower  
flame. The burner aeration is factory set but  
may need adjusting due to either the local gas  
supply or altitude. This adjustment is performed  
by the gas fitter.  
Minimum Air Shutter Opening:  
The manifold pressure is controlled by a  
regulator built into the gas control, and should  
be checked at the pressure test point.  
8 mm  
NG  
Full Open LPG  
CAUTION:Carbonwillbeproducedifairshutter  
Note: To properly check gas pressure, both  
inlet and manifold pressures should  
becheckedusingthevalvepressure  
ports on the valve.  
is closed too much.  
Note: Any damage due to carboning  
resulting from improperly setting  
the aeration controls is NOT covered  
under warranty.  
1) Make sure the valve is in the "OFF"  
position.  
2) Loosen the "IN" and/or "OUT" pressure  
tap(s), turning counterclockwise with a  
1/8" wide flat screwdriver.  
Closed - Tall yellow  
Open - Short Blue  
3) Attach manometer to "IN" and/or "OUT"  
pressure tap(s) using a 5/16" ID hose.  
Regency® P36-4 Gas Log Fireplace  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
4) Light the pilot and turn the valve to "ON"  
OPTIONAL  
LOG SET  
position.  
BRICK PANELS  
INSTALLATION  
5) The pressure check should be carried out  
with the unit burning and the setting should  
be within the limits specified on the safety  
label.  
1) Undo the bottom 2 door latches and open  
Read the instructions below carefully and  
refer to the diagrams. If logs are broken  
do not use the unit until they are replaced.  
Broken logs can interfere with the pilot  
operation.  
and remove glass door. Remove logs.  
Note: The logs must not be in the unit.  
6) When finished reading manometer, turn  
off the gas valve, disconnect the hose and  
tighten the screw (clockwise) with a 1/8" flat  
screwdriver.Note:Screwshouldbesnug,  
but do not over tighten.  
2) Insert the back brick panel first by carefully  
slipping it between the back wall of the  
firebox and the rear log bracket.  
The gas log kit (Part # 512-930) contains the  
following pieces:  
a) 02-49 Rear Log  
b) 02-55 Middle Left Log  
c) 02-50 Front Left Log  
d) 02-53 Center Left Log  
e) 02-51 Front Bottom Log  
f) 02-54 Center Right Log  
g) 02-52 Middle Right Log  
S.I.T. VALVE DESCRIPTION  
1) Gas on/off knob  
2) Manual high/low adjustment  
3) Pilot Adjustment  
3) Put the side panels in next. Slide them in  
from the front and push them flat up against  
the wall. Be very careful not to scratch them  
on the firebox hardware.  
h)  
i)  
Embers  
902-156  
902-179  
4) Thermocouple Connection - option  
5) Outlet Pressure Tap  
6) Inlet Pressure Tap  
Vermiculite  
7) Pilot Outlet  
8) Main Gas Outlet  
9) Alternative TC Connection Point  
4) Install the 2 brick retaining clips, one on  
each side.  
The "02" refer numbers (i.e. 02-49) are  
molded into the rear of each log.  
NOTE: If you will be installing the optional  
Brick Panels, install the Brick Panels  
prior to installing the logs.  
1) Carefully remove the logs from the box and  
unwrap them. The logs are fragile, handle  
with care - do not force into position.  
2) Sprinkle the vermiculite around the firebox  
base.  
Vermiculite  
Vermiculite  
Vermiculite  
3) Place the Log 02-49 on the rear log support  
pins with the flat side to the back.  
Regency® P36-4 Gas Log Fireplace  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
8) Position Log 02-54 across the cutouts in  
Logs 02-51 and 02-53. The notch in the  
bottom right end fitting against the 5th grate  
tab.  
02-49  
02-49  
02-53  
02-51  
02-54  
6) Place the bottom left front edge of Log  
02-55againsttherearbracketontheburner  
tray and rest the log on the cutout on  
Log 02-53.  
02-51  
02-49  
5th Grate Tab  
02-55  
4) Place Log 02-51 on the front right side of  
the burner. Push the back of the log against  
the 2 brackets with the notch on the bottom  
right side of the log fitting into the right side  
of the grate.  
02-49  
02-55  
02-51  
02-53  
02-50  
02-51  
02-54  
02-51  
Rear Bracket  
9) Place Log 02-52 between Logs 02-51 and  
02-49 and on the indentation on Log 02-54.  
The bottom right end sits behind the rear  
grate tab.  
7) Sit Log 02-50 on the front left side of the  
burner. Push the back of the log against the  
2frontbracketswiththenotchonthebottom  
of the log fitting into the first grate tab.  
02-55  
Bracket  
Bracket  
Notch  
02-49  
02-52  
02-50  
02-49  
02-53  
02-51  
02-51  
02-54  
Front Brackets  
Log indentation  
5) Position Log 02-53 across the cutouts in  
Logs 02-49 and 02-51 with the notch on the  
left side of the log fitting into the 2nd grate  
tab.  
02-55  
02-53  
02-52  
02-50  
02-53  
Rear  
Grate  
02-49  
02-51  
02-54  
Tab  
Photo shows rear grate tab.  
Log 02-51 was removed to show  
the positioning of Log 02-52.  
Notch  
2nd Grate Tab  
Cutouts  
Regency® P36-4 Gas Log Fireplace  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
10) Place the embers on the front of the burner  
tray in the places shown on the photo.  
02-49  
02-55  
02-52  
02-50  
02-51  
Place embers in these 3 locations  
on the burner tray.  
02-54  
11) Test fire to ensure proper light off (make sure flame flows smoothly from one end of burner  
to the other). If there is any flame hesitation, check that area for any blockage of the burner  
ports.  
Embers  
STANDARD FLUSH DOOR  
Use the hook to pull the spring out until you  
The standard flush door comes with a black  
frame. To install the frame, simply hook the top  
door flange onto the top of the unit and swing  
the door towards the unit, diagram 1.  
Flush Louvres  
can put the hook into the slot on the bottom  
door bracket. Repeat for 2nd spring. See  
diagram 3.  
1) Install the top louvre by sliding the two  
bracket clips into the brackets located  
underneath the top of the firebox.  
2) The bottom louvre has a hinge that is  
attached (2 screws per hinge) to the lip on  
bottom of the unit.  
Diagram 3  
Diagram 1  
To remove the flush door, reverse the above  
steps.  
Optional  
Flush Trim  
Attach the round  
magnets to the  
back of the top trim  
piece and to the  
bottom trim piece,  
then attach trim to  
the top and bottom  
of Flush door.  
Be careful that the glass gasket does not roll up;  
there must be a gap between the gasket and  
the door lip to ensure that the door sits securely  
on the unit. Diagram 2.  
Note: Top and bottom louvres are  
different.  
Diagram 2  
Regency® P36-4 Gas Log Fireplace  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
PREMIUM FLUSH FRONT INSTALLATION  
1) Unplug the power source.  
6) Remove the manual control switch bracket by undoing the 2  
screws.  
2) Remove the top louver (if fitted) by carefully pulling it out.  
3) Install the premium flush front top louver in place by sliding the louver  
tabs into the louver brackets on the inside top of the firebox.  
Louver Tab  
7) Remove the burner ON/OFF switch from the bracket using a pair  
of pliers and remove the 2 screws that secure the 2 wires on the  
valve.  
Burner ON/OFF  
Switch  
Premium Flush Front Top Louver in place.  
Valve  
4) Open the bottom louver.  
5) Remove the bottom louver (if fitted) by undoing the 2 screws which  
8) Install the new ON/OFF switch to the manual control switch  
secure the louver to the hinges on the left and right side.  
bracket.  
Regency® P36-4 Gas Log Fireplace  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
12) Place the wire grommet back into the thermodisc cover with the 2  
9) Connect the female connecter on the white wire to the TH terminal  
female ends of the wires inside the cover as shown.  
of the valve.  
10) Remove the thermodisc cover from the thermodisc plate by undoing  
the 2 screws and then remove the wire grommet.  
13) Connect the female ends of the red and white wires to the thermo-  
disc.  
Thermodisc Plate  
Thermodisc Cover  
Grommet  
14) Reattach the thermodisc plate to the thermodisc cover using the 2  
screws removed in step 10.  
11) Take the white wire from the kit and the red wire from the burner  
ON/OFF switch and place the grommet thru the wires.  
Regency® P36-4 Gas Log Fireplace  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
15) Connect the thermodisc wire harness to the new valve/module wire  
22) Install the wire cover by fitting the 3 clips onto the flange at the front  
harness. Refer to the wiring diagram on next page for details.  
of the firebox. See note below for P36 units.  
16) Mountthethermodiscbrackettotheadjustablebracketusing2screws.  
Important: Thermodisc location is crucial, check the data badge to  
identify unit and secure to screw location accordingly.  
Wire Cover  
17) Remove the left side bottom hinge bracket by undoing the 2  
screws.  
Firebox Flange  
18) Install the supplied hinge to the hinge bracket using 2 screws.  
19) Slide the adjustable bracket to the bottom left corner and secure in  
place using the 2 screw holes on the firebox flange.  
One clip shown in place  
on firebox flange.  
NOTE - P36 UNITS ONLY:  
For the wire cover to fit in place on the P36 the top half of the wire  
cover will need to be broken off by bending back and forth.  
Bend Here  
20) Secure loose wires using wire clips to the base of the firebox as far  
back as possible.  
21) Place the manual control bracket back into it's original location and  
secure using 2 screws.  
23) Align the bottom louver mounting tab with hinges on the left and right  
side and secure using 2 screws on each side.  
24) Plug in power source.  
25) Close the bottom louver.  
NOTE:  
The fan must run at minimum speed to prevent the unit from overheating  
which will cause automatic shutdown via the thermodisc safety switch.  
Regency® P36-4 Gas Log Fireplace  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Option 1:  
Option 2:  
Option 3:  
WALL SWITCH  
REMOTE CONTROL  
WALL THERMOSTAT  
1) Run supplied 15' of wire through the right UsetheRegency® RemoteControlKit approved A wall thermostat may be installed if desired,  
or left side gas inlet opening. Be careful not for this unit. Use of other systems may void  
to damage wire. your warranty.  
connect the wires as per the wiring diagram.  
Use chart below to determine the maximum  
wire length.  
Note: We recommend a maximum of 15' The remote control kit comes with a hand held  
of wire but if you wish to go with a transmitter, a receiver and a wall mounting  
longer run, use the Thermostat Wire plate.  
Note: Preferable if the thermostat is  
installed on an interior wall.  
Table.  
1) Choose a convenient location on the wall  
2) Connect wire to supplied wall switch and  
to install the receiver and the receptacle  
box (protection from extreme heat is very  
important). Run wires from the fireplace to  
that location. Use Thermostat Wire Table.  
Regency® offers a programmable thermostat  
but any CSA, UCL or UL approved millivolt  
thermostat, 250-750 millivolt rated non-  
anticipator type thermostat may be used.  
install into the receptacle box.  
CAUTION  
Do not connect millivolt  
2) Connect the two wires to the gas valve. See  
CAUTION  
wall switch wires for gas  
appliance to a 240V power supply.  
diagram below.  
Do not connect millivolt  
wall thermostat wires for  
gas appliance to a  
CAUTION  
Do not connect millivolt  
remote control wires for  
gas appliance to a  
240V power supply.  
240V power supply.  
Thermostat Wire Table  
3) Install a 9V alkaline battery in both the  
receiver and the transmitter. Install the  
receiver and its cover in the wall. Switch the  
hand held remote transmitter to "remote"  
mode. The remote control is now ready for  
operation.  
Recommended Maximum Lead Length  
(Two-Wire) When Using Wall  
Thermostat (CP-2 System)  
Wire Size  
Max. Length  
14 GA.  
16 GA.  
18 GA.  
20 GA.  
22 GA.  
15.24 m  
9.75 m  
6.10 m  
3.66 m  
2.71 m  
Regency® P36-4 Gas Log Fireplace  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
WIRING  
This heater does not require a 240VA.C. supply  
forthegascontroltooperate.A240VA.C.power  
supply is needed for the fan/blower operation.  
Caution: Ensure that the wires do  
not touch any hot surfaces and are  
away from sharp edges.  
CAUTION: Label all wires prior  
to disconnection when servicing  
controls. Wiring errors can  
cause improper and dangerous  
operation.  
STANDARD WIRING  
WARNING: Electrical Grounding Instructions  
This appliance is equipped with a three pronged (grounding) plug for your  
protectionagainstshockhazardandshouldbepluggeddirectlyintoaproperly  
grounded three-prong receptacle. Do not cut or remove the grounding prong  
from this plug.  
Regency® P36-4 Gas Log Fireplace  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
WIRING WITH PREMIUM FLUSH FRONT OPTION  
Regency® P36-4 Gas Log Fireplace  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
7) Slide the thermodisc into the bracket clip  
OPERATING  
INSTRUCTIONS  
OPTIONAL  
FAN  
on the underside of the firebox.  
8) Connect black wire from fan to the  
thermodisc.  
240 Volt AC power is needed for the fan switch  
andblower.Thefancanbehardwiredifdesired.  
Aterminalblockisprovidedonthelefthandside  
of the unit. A three wire power cord can also be  
used and plugged into a suitable receptacle.  
1) Read and understand these instructions  
before operating this appliance.  
2) Check to see that all wiring is correct and  
enclosed to prevent possible shock.  
Unit must be grounded at all times. Do  
not cut the ground terminal off under any  
circumstances.  
3) Check to ensure there are no gas leaks.  
4) Make sure the glass in the door frame is  
properly positioned. Never operate the  
appliance with the glass removed.  
1) Shut the power off.  
9) Connect fan ground cable to ground lug.  
2) Open the bottom louvre door.  
3) Remove the terminal block cover.  
5) Verify that the flueing and cap are  
Refer to wiring diagram.  
unobstructed.  
10) Attach the ground wire to the stove (ground  
6) Ensure that the brick panels are installed.  
lug provided).  
4) Slide the fan in towards the rear of the unit  
and slip it over the two mounting studs.  
Ensure that the fan blades do not rub  
against the valve tubing.  
7) Verify log placement. If the pilot cannot be  
seen when lighting the unit, the logs have  
been incorrectly positioned.  
11) Attachblackwirefromthermodisctoterminal  
block.  
12) Hard wire into terminal block and to fan  
8) The unit should never be turned off, and on  
again without a minimum of a 60 second  
wait.  
speed controller. Wires not supplied.  
Note: A 240 Volt AC power cord can be  
installed at rough-in stage so that  
the power is available. A three wire  
power cord can be used.  
13) Attach the terminal block cover. If the left  
springwasunhookedinstep4),hookitback  
into the bracket.  
To Remove the Fan  
1) Shut the power off.  
2) Reverse the above instructions.  
Note: The bearings are lubricated for life.  
Do not lubricate them. Make sure  
you vacuum the fan area on a regular  
basis.  
Optional: If you require extra space to slide  
the fan to the back, the left spring can be  
unhooked from the bracket.  
IMPORTANT:  
5) Wire the fan to the terminal block as shown  
These fans collect a lot of dust from within  
your home. Ensure you maintain these fan  
motors on a regular basis by vacuuming  
out the fan blades and housing using a soft  
brush nozzle.  
in the wiring diagram below.  
6) Connect white wire from fan to neutral of  
terminal block.  
Regency® P36-4 Gas Log Fireplace  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
NORMAL OPERATING  
SOUNDS OF GAS  
APPLIANCES  
It is possible that you will hear some sounds  
fromyourgasappliance.Thisisperfectlynormal  
due to the fact that there are various gauges  
and types of steel used within your appliance.  
Listedbelowaresomeexamples.Allarenormal  
operatingsoundsandshouldnotbeconsidered  
as defects in your appliance.  
LIGHTING  
FIRST FIRE  
PROCEDURE  
The first fire in your stove is part of the paint  
curing process. To ensure that the paint is  
properlycured, itisrecommendedthatyouburn  
your fireplace for at least four (4) hours the first  
time you use it with the fan on.  
1) Push in gas control knob slightly and turn to  
“PILOT” position.  
2) Push in control knob all the way and hold in  
until the pilot lights up. Continue to hold the  
control knob in for about 20 seconds after the  
pilot is lit. Release knob.  
Whenrstoperated,theunitwillreleaseanodour  
caused by the curing of the paint, the burning  
off of any oils remaining from manufacturing.  
Smoke detectors in the house may go off at  
this time. Open a few windows to ventilate the  
room for a couple of hours.  
3) Push in gas control knob slightly and  
turn to "ON" position.  
Blower:  
Regency® gasappliancesusehightechblowers  
to push heated air farther into the room. It is not  
unusual for the fan to make a "whirring" sound  
when ON. This sound will increase or decrease  
in volume depending on the speed setting of  
your fan speed control.  
4) Turn ON the flame switch.  
The glass panel may require cleaning after the  
unit has cooled down.  
DO NOT ATTEMPT TO CLEAN THE  
GLASS WHILE IT IS HOT.  
Gas Inlet  
Burner Tray:  
Note: When the glass is cold and the  
appliance is lit, it may cause  
condensation and fog the glass.  
This condensation is normal and  
will disappear in a few minutes as  
the glass heats up.  
The burner tray is positioned directly under the  
burnertube(s)andlogsandismadeofadifferent  
gauge material from the rest of the firebox and  
body.Therefore,thevaryingthicknessesofsteel  
will expand and contract at slightly different  
rates which can cause "ticking" and "cracking"  
sounds. You should also be aware that as there  
are temperature changes within the unit these  
sounds will likely re-occur. Again, this is normal  
for steel fireboxes.  
SHUTDOWN  
PROCEDURE  
DO NOT BURN THE APPLIANCE  
WITHOUT THE GLASS FRONT IN  
PLACE.  
1) Turn OFF the flame switch.  
Blower Thermodisc:  
When this thermally activated switch turns ON  
it will create a small "clicking" sound. This is the  
switch contacts closing and is normal.  
2) Push in gas control knob slightly and turn to  
"OFF" position.  
During the first few fires, a white film  
may develop on the glass front as part  
of the curing process. The glass should  
be cleaned or the film will bake on and  
become very difficult to remove. Use a  
non-abrasive cleaner and NEVER clean  
the glass while it is hot.  
Pilot Flame:  
While the pilot flame is on it can make a very  
slight "whisper" sound.  
Gas Control Valve:  
As the gas control valve turns ON and OFF, a  
dullclickingsoundmaybeaudible,thisisnormal  
operation of a gas regulator or valve.  
Unit Body/Firebox:  
Different types and thicknesses of steel will  
expand and contract at different rates resulting  
in some "cracking" and "ticking" sounds will be  
heard throughout the cycling process.  
Regency® P36-4 Gas Log Fireplace  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
COPY OF THE LIGHTING PLATE INSTRUCTIONS  
MAINTENANCE  
INSTRUCTIONS  
1) Alwaysturnoffthegasvalvebeforecleaning.  
For relighting, refer to lighting instructions.  
Keep the burner and control compartment  
clean by brushing and vacuuming at least  
once a year. When cleaning the logs, use a  
soft clean paint brush as the logs are fragile  
and easily damaged.  
FORYOURSAFETYREADBEFORELIGHTING  
This appliance must be installed in accordance with local codes, if any; if not, follow the  
current CAN1-B149/ANSI Z 223.1 (Australia: AS5601-2004, New Zealand: NZS 5261)  
WARNING: If you do not follow these instructions exactly, a fire or  
explosion may result causing property damage, personal injury or loss  
oflife.Improperinstallation,adjustment,alteration,serviceormaintenance  
can cause injury or property damage. Refer to the owner’s information  
manual provided with this appliance. For assistance or additional  
information consult a qualified installer, service agency or gas supplier.  
2) Clean appliance and door with a damp  
cloth (never when unit is hot). Never use  
an abrasive cleaner. The glass should be  
cleaned with a gas fireplace glass cleaner.  
The glass should be cleaned when it  
starts looking cloudy.  
A)This appliance has a pilot which C)Use only your hand to push in or turn  
must be lighted by hand. When  
lighting the pilot, follow these  
instructions exactly.  
the gas control knob. Never use tools.  
If the knob will not push in or turn by  
hand, don’t try to repair it, call a  
qualified service technician. Force or  
attempted repair may result in a fire  
or explosion.  
3) The heater is finished in a heat resistant  
paintandshouldonlyberefinishedwithheat  
resistant paint. Regency® uses StoveBright  
Paint - Metallic Black #6309.  
B)BEFORE LIGHTING smell all around  
the appliance area for gas. Be sure  
to smell next to the floor because  
4) Make a periodic check of burner for proper  
position and condition. Visually check the  
flameoftheburnerperiodically,makingsure  
the flames are steady; not lifting or floating.  
If there is a problem, call an authorized  
service person.  
some gas is heavier than air and D)Do not use this appliance if any part  
will settle on the floor.  
has been under water. Immediately  
call a qualified service technician to  
inspect the appliance and to replace  
any part of the control system and any  
gas control which has been under  
water.  
WHAT TO DO IF YOU SMELL GAS  
- Do not try to light any appliance  
- Do not touch any electric switch, do  
not use any phone in your building  
- Immediately call your gas supplier  
5) The appliance and flueing system must be  
inspected before use, and at least annually,  
by an authorized field service person, to  
ensure that the flow of combustion and  
ventilation air is not obstructed.  
from a neighbours phone. Follow This appliance needs fresh air for safe  
the gas supplier’s instructions. operation and must be installed so there  
- If you cannot reach your gas are provisions for adequate combustion  
supplier, call the fire department. and ventilation air.  
CAUTION:Hotwhileinoperation.Donottouch.SevereBurnsmayresult.Due  
tohighsurfacetemperatureskeepchildren,clothingandfurniture,gasoline  
and other liquids having fammable vapors away. Keep burner and control  
compartment clean. See installation and operating instructions  
accompanyingappliance.  
Note: Never operate the appliance without  
the glass properly secured in  
place.  
6) Donotusethisapplianceifanyparthasbeen  
underwater.Immediatelycallanauthorized  
service technician to inspect the appliance  
andtoreplacenaypartofthecontrolsystem  
and any gas control which has been under  
water.  
LIGHTINGINSTRUCTIONS  
STOP! Read the safety information above on this label.  
1) Push in gas control knob slightly and turn to “PILOT” position.  
7) Verify operation after servicing.  
2) Push in control knob all the way and hold in until the pilot lights up. Continue  
to hold the control knob in for about 20 seconds after the pilot is lit. Release  
knob.  
General Flue Maintenance  
3) Push in gas control knob slightly and  
turn to "ON" position.  
Conduct an inspection of the flueing system  
semi-annually. Recommended areas to inspect  
as follows:  
Gas Inlet  
4) Turn ON the flame switch.  
1) Check the Flueing System for corrosion in  
areas that are exposed to the elements.  
These will appear as rust spots or  
streaks, and in extreme cases, holes.  
These components should be replaced  
immediately.  
TO TURN OFF GAS APPLIANCE  
You may shut off the pilot during prolonged non use periods to conserve fuel.  
1) Turn OFF the flame switch.  
2) Push in gas control knob slightly and turn to "OFF" position.  
2) Remove the Cap, and shine a flashlight  
down the Flue. Remove any bird nests, or  
other foreign material.  
DO NOT REMOVE THIS INSTRUCTION PLATE  
918-253a  
Regency® P36-4 Gas Log Fireplace  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
3) Check for evidences of excessive  
condensation,suchaswaterdropletsforming  
in the inner liner, and subsequently dripping  
outthejoints,Continuouscondensationcan  
cause corrosion of caps, pipe, and fittings.  
It may be caused by having excessive  
lateral runs, too many elbows, and exterior  
portions of the system being exposed to  
cold weather.  
Flush Glass Replacement  
THERMOPILE /  
Remove the flush door front (as per instructions  
in section "Standard Flush Door"). Remove  
the 4 glass clips from each corner. Slide in the  
new replacement glass. Push the 4 glass clips  
back onto the frame. The glass must have  
gasketing around it.  
THERMOCOUPLE  
1) Open the bottom louvres.  
2) Loosenthethermocoupleorthermopilewith  
a 7/16" spanner.  
3) Disconnect thermocouple by loosening  
nut from the valve with a 9mm spanner.  
Disconnect thermopile by loosening 2  
screws marked TP on the valve.  
4) Inspect joints, to verify that no pipe  
sections or fittings have been disturbed,  
and consequently loosened. Also check  
mechanical supports such as Wall Straps,  
or plumbers' tape for rigidity.  
4) Drop the thermocouple or thermopile down  
from the bracket and pull it out of the unit.  
5) Reinstall the new ones in reverse order.  
GOLD-PLATED &  
BRASS  
GLASS GASKET  
If the glass gasket requires replacement use  
5/8" flat glass gasket for the Bay Front (Part  
# 936-243) and a tadpole glass gasket for the  
Flush Front (Part # 936-155).  
LOUVRES OR TRIM  
The 24 carat gold plated or brass finish on the  
trim requires little maintenance, and need only  
be cleaned with a damp cloth. DO NOT use  
abrasive materials or chemical cleaners, as  
they may harm the finish and void the warranty.  
Cleananyngerprintsoff beforeturningthe  
unit on. If the top louvres start to discolour,  
check the door gasket seal and replace if  
necessary.  
DOOR GLASS  
Your Regency® fireplace is supplied with high  
temperature,5mmNeoceramceramicglassthat  
will withstand the highest heat that your unit will  
produce. If your glass requires cleaning, we  
recommend using an approved glass cleaner  
available at all authorized dealers. Do not use  
abrasive materials. Do not clean the glass  
when hot.  
Bay Glass Replacement  
1) Remove the door from the unit and place  
on a soft surface to prevent scratching.  
LOG REPLACEMENT  
2) Remove the nuts holding the glass clips in  
place and remove.  
The unit should never be used with broken logs.  
Turn off the gas valve and allow the unit to cool  
before opening door and carefully remove the  
logs. (The pilot light generates enough heat to  
burn someone.) If for any reason a log should  
need replacement, you must use the proper  
replacement log. The position of these logs  
must be as shown in the diagrams under Log  
Installation.  
3) Replace the glass. The glass must have  
gasketing around it.  
Intheeventthatyoubreakyourglassbyimpact,  
purchase your replacement from an authorized  
Regency® dealer only, and follow our step-by-  
step instructions for replacement.  
5) Reversetheprevioussteps,replacetheglass  
clips and fasten with the nuts but do not over  
tighten, as this can break the glass.  
WARNING: Do not operate the  
appliance with the glass panels  
removed, cracked or broken.  
Replacement of the glass panels  
should be done by a licensed or  
qualified service person.  
6) Replace door on the stove and check the  
seal.  
Note: Improper positioning of logs may  
create carbon build-up and will  
severely alter the unit's performance  
which is not covered under  
warranty.  
Caution: Wear gloves when  
removing damaged or broken  
glass.  
Regency® P36-4 Gas Log Fireplace  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
10) Undo the pilot tube from the valve with a  
REMOVING VALVE  
INSTALLING VALVE  
7/16" spanner.  
1) Shut off the gas supply.  
1) Attach the valve to the valve bracket with  
11) Undo the quick drop out thermocouple nut  
the 4 (m5x8 metric) screws provided.  
on the valve with a 9mm (metric) spanner.  
2) Remove the louvres (and bay door if it is  
on).  
2) Reconnect the "gas out" flare fitting with an  
12) Remove the Piezo igniter wire and push  
11/16" spanner.  
button assembly.  
3) Open the flush door and remove the door.  
3) Reconnect the "gas out" flare nut with a  
13) Undo the "gas out" flare nut with a 13/16"  
4) Remove the logs.  
13/16" spanner.  
spanner.  
5) Remove the burner/grate assembly by  
removing the two Phillips head screws and  
then lift the burner assembly out.  
4) Install piezo ignitor push button assembly  
14) Undo the "gas out" flare fitting with an 11/16"  
and reconnect wire.  
spanner.  
5) Reconnectthequickdropoutthermocouple  
15) Remove the 4 Phillips head screws from  
the sides of the valve bracket and remove  
valve.  
nut with a 9mm spanner.  
6) Reconnect the pilot tube nut with a 7/16"  
spanner.  
7) Scrapeofftheoldgasketfromtheoorofthe  
firebox and from the valve tray assembly.  
8) Install a new gasket and reinstall the valve  
tray assembly.  
Note: Failure to install a new gasket  
may severely affect the appliance  
performance.  
9) Reinstall the 10 hold down screws.  
10) Hook up the 2 TP and 2 TH wires to the  
appropriate connections on the valve.  
11) Reinstall the front log stand.  
Diagram 1: Remove the left and right screws  
and then lift out the burner/grate assembly.  
12) Install Burner/grate assembly  
6) Remove the rear log stand by removing the  
13) Hook up the gas line and check for gas  
leaks with a soap and water solution or a  
gas leak detector. (Do not use open flame  
for leak testing.)  
2 screws.  
screws  
Rear Log Stand  
Hint:  
If you are using black pipe, ensure  
that there is a union by the valve,  
otherwise removal will be almost  
impossible.  
14) Fire up the unit temporarily  
15) Check the manifold pressure.  
16) Reinstall the logs and brick panels as  
needed.  
17) Close the door and replace the louvres.  
18) Fire up the unit again and check for proper  
screws  
Valve Tray Assembly  
flame appearance and glow on logs.  
Diagram 2: Rear Log Stand and  
Valve Tray Assembly  
7) Disconnect the inlet gas line. See diagram  
2.  
8) Disconnect the 2 TP wires and the 2 TH  
wires from the valve.  
9) Removethe10Phillipsheadscrewssecuring  
thevalvetrayassemblyinplace(diagram2)  
andthenlifttheentireassemblyout diagram  
3).  
Regency® P36-4 Gas Log Fireplace  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
MAIN ASSEMBLY  
Part #  
Description  
1) 910-142  
Thermodisc-Fan Auto ON/OFF  
Thermodisc Bracket  
Chain  
2)  
*
3) 948-045  
4) 948-025  
6) 510-125  
7) 910-006  
8) 510-126  
9) 910-140  
10) 910-246  
Spring  
Terminal Block Housing  
Terminal Block  
Terminal Block Cover  
Fan Switch HIGH/OFF/LOW  
Burner Switch ON/OFF  
12) 910-169/P Fan Motor  
31  
30  
910-520  
910-714  
Wire Harness  
Power Cord (240 V)  
14) 510-026  
15) 948-253  
Hinge Bracket - Left/Right  
Door Handle  
17)  
*
Wire Holder Clip  
20) 510-033  
21) 510-064  
22) 510-153  
23) 510-011  
24) 511-044  
Top Nailing Strip  
Side Nailing Strip  
Baffle Plate  
28  
30  
Standoff - Top  
Standoff - Side/Back  
Outer Flue Collar  
Inner Flue Collar Assembly  
Gasket for Flue Collar  
Flue Mounting Plate  
27)  
28)  
30)  
31)  
*
*
*
*
22  
23  
27  
513-901  
Brick Panel Set - Standard Brown  
Brick Panel Set - Standard Red  
Brick Panel Set - Herringbone Brown  
Brick Panel Set - Herringbone Red  
Brick Panel - Back  
20  
513-902  
513-903  
513-904  
*
*
*
33)  
34)  
35)  
23  
Brick Panel - Left  
Brick Panel - Right  
24  
36) 910-073  
37) 910-074  
Spark Generator Battery Holder  
Spark Generator Switch c/w Wire  
511-031  
Brick Clip (each)  
21  
918-538  
513-968  
Manual  
Conversion Kit - NG to LPG  
17  
14  
6
7
4
3
8
33  
15  
1
24  
14  
2
21  
37  
36  
10  
9
34  
BRICKPANELSET  
DOORS&LOUVERSPLEASE  
REFER SEPARATESECTION  
35  
Regency® P36-4 Gas Log Fireplace  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
BURNER ASSEMBLY & LOG SET  
Part #  
Description  
513-560/P  
513-562/P  
52) *  
Valve Assy - NG  
Valve Assy - LPG  
Valve Tray -NG  
92  
53) 430-055  
54) 910-421  
55) 910-422  
57) 910-478  
58) *  
Gasket - Valve Access Plate  
Pilot ON/OFF 3" Extension Knob  
HI/LOW 3" Extension Knob  
S.I.T. Valve - NG/LPG  
Valve Bracket  
93  
94  
95  
98  
59) *  
Firebox Base  
65) *  
Pilot Bracket  
97  
66) 910-038  
910-039  
904-240  
904-390  
910-036  
910-037  
936-170  
67) *  
Pilot Assy-NG 3 way flame-S.I.T.  
Pilot Assy-LPG 3 way flame-S.I.T.  
Orifice #37 - NG (Burner)  
Orifice #52 - LPG (Burner)  
Pilot Orifice - NG  
96  
Pilot Orifice - LPG  
Orifice Gasket  
Pilot Holder  
68) W840470  
Pilot Assembly Gasket  
79) 512-525  
82) 511-030  
84) *  
85) 512-930  
86) 910-386  
87) 910-341  
88) 910-096  
Burner Assy - NG  
Burner Grate Assy  
Rear Log Support Assy  
Log Set  
Thermocouple  
Thermopile  
Pilot Hood (3-way)  
92) *  
93) *  
94) *  
95) *  
96) *  
97) *  
98) *  
Rear Log  
Middle Right Log  
Front Left Log  
Center Left Log  
Center Right Log  
Front Bottom Log  
Middle Left Log  
*Not available as a replacement part.  
Regency® P36-4 Gas Log Fireplace  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
BAY FRONT ASSEMBLY  
Part #  
Description  
Part #  
Description  
Bay Louvres - Black  
780-931  
Bay Front Complete  
510-988  
510-990  
510-992  
510-993  
*
103) 940-092/P Side Glass  
Bay Louvres - Gold/Black  
Bay Louvres - Brass/Black  
Bay Louvres - Steel/Black  
Bay Louvre Assy-Top  
107) 936-243  
Glass Gasket - Soft Fibre Black  
108) 940-094/P Center Glass  
111) 780-905  
780-906  
Brick Panel Inlay - Rustic Brown Bay  
Brick Panel Inlay - Old Town Red Bay  
115)  
116)  
*
Bay Louvre Assy-Btm  
780-938  
780-936  
*
Bay Front Trim - Brass  
Bay Front Trim - Steel  
Bay Front Trim -Top/Bottom  
117) 904-196  
120)  
Magnet (1" round)  
Flush Glass Retainer Bracket  
*
112)  
*Not available as a replacement part.  
780-934  
*
*
Bay Door Trim - Gold  
Bay Door Trim-Gold-Bottom  
Bay Door Trim-Gold-Top  
113)  
114)  
Regency® P36-4 Gas Log Fireplace  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
FLUSH FRONT ACCESSORIES  
Part #  
Description  
132) 512-518  
Flush Door Assembly  
135) 940-090/P Glass (Flush)  
136) 936-155  
904-691  
Glass Gasket (Tadpole)  
U-Clip (each)  
510-920  
510-921  
510-922  
510-923  
138) *  
Flush Louvres - Gold/Black  
Flush Louvres - Brass/Black  
Flush Louvres - Black  
Flush Louvres - Steel/Black  
Flush Louvre Assy-Top  
Flush Louvre Assy-Btm  
139) *  
136  
138  
135  
510-954  
146) *  
Barcelona Surround - Black  
Barcelona Assy  
148) *  
Barcelona Louvre Assy  
150  
152  
510-932  
150) *  
Flush Glass Trim - Gold (2/Set)  
Flush Glass Trim-Gold  
904-196  
Magnet (1" round)  
146  
510-934  
510-947  
152) *  
Flush Glass Trim - Brass (2/Set)  
Flush Glass Trim - Steel (2/Set)  
Flush Glass Trim-Brass  
148  
904-196  
Magnet (1" round)  
132  
139  
510-986  
510-909  
510-910  
157) *  
Finishing Trim (3 piece) - Black  
Finishing Trim (3 piece) - Steel  
Finishing Trim (4 piece) - Steel  
Finishing Trim Left  
158) *  
Finishing Trim Top  
159) *  
160) *  
Finishing Trim Right  
Finishing Trim Bottom  
157  
158  
161) 513-949  
Flush Door Screen Pkg.  
*Not available as a replacement part.  
159  
160  
161  
Regency® P36-4 Gas Log Fireplace  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
PREMIUM FLUSH FRONT ASSEMBLY  
Part #  
Description  
516-916  
Premium Flush Front - Black  
Wiring  
513-948  
910-975  
Thermodisc  
180)  
181)  
182)  
183)  
*
*
*
*
Top Louver  
Bottom Louver  
Thermodisc Mounting Bracket  
Spacers  
*Not available as a replacement part.  
Regency® P36-4 Gas Log Fireplace  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
CAST FACEPLATE ASSEMBLY  
Part #  
Description  
513-971  
Cast Faceplates (Set) - Black Metallic  
201) *  
Cast Faceplate - Right  
Cast Faceplate - Top  
Cast Faceplate - Left  
202) *  
203) *  
513-991  
204) *  
205) *  
Cast Grills (Set) - Black Metallic (Aust. only 240 volt)  
Cast Grill - Top  
Cast Grill - Bottom  
513-976  
Cast Faceplates (Set) - Black Enamel  
Cast Faceplate - Right  
201) *  
202) *  
203) *  
Cast Faceplate - Top  
Cast Faceplate - Left  
513-996  
204) *  
205) *  
Cast Grills (Set) - Black Enamel (Aust. only 240 volt)  
Cast Grill - Top  
Cast Grill - Bottom  
* Not available as a replacement part.  
Regency® P36-4 Gas Log Fireplace  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
Regency® P36-4 Gas Log Fireplace  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
___________________________________________________  
Regency® P36-4 Gas Log Fireplace  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal QualityAssurance Team carefully  
inspects each unit thoroughly before it leaves our door. FPI is pleased to extend this limited lifetime warranty to the original purchaser  
of a Regency® Product.  
The Warranty: Lifetime  
Covered under the agreement are the following components: Combustion chamber, heat exchanger, burner tubes, logs, embers, glass (thermal  
breakage) and all gold plating against defective manufacture.  
NOTE: Gold Plated Barcelona Front - slight imperfections in the gold plating are due to the plating process and are not considered defects.  
The above will be covered for parts and labour for the first five years and parts only thereafter.  
Electrical components such as blowers, switches, wiring, thermodiscs, remote control, thermopiles, thermocouples and gas valves are covered for  
one year from the date of purchase.  
The warranty on brass parts is for one year, no labour. The brass is not warranted against tarnishing.  
Conditions:  
All installations must be performed by a qualified gas fitter and installed according to all applicable local and national codes. Also, all service  
work must be carried out by a qualified gas service person provided by the selling dealer. It is the responsibility of the installer to ensure that  
the appliance is firing as per rating plate. Any part or parts of this unit which in our judgement show evidence of such defect will be repaired or  
replaced at Regency®'s option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent  
Transportation Prepaid, if requested. In areas where there is not an approved service agent or the closest approved service agent is situated  
more than twenty-five (25) kilometres from the installation, Australian Heating Distributors are not obliged to arrange warranty repairs and travel  
and/or additional labour charges will apply.  
Exclusions:  
This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim. It does not cover installation and operational  
related problems such as over-firing, downdrafts or spillage caused by environmental conditions, nearby trees, buildings, hilltops, mountains,  
inadequate flueing or ventilation, excessive offsets, negative air pressures caused by insufficient make up air, mechanical systems such as furnaces,  
fans, clothes dryers etc.  
The warranty does not extend to any part or parts which show evidence of misuse or abuse, neglect, accident, lack of maintenance, or improper  
installation.  
Products made by other manufacturers and used in conjunction with the operation of this appliance without authorization from Regency®, may  
nullify your warranty on this product.  
FPI Ltd., shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original  
purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the  
responsibility of FPI.  
General:  
It is essential that all submitted claims provide all of the necessary information including purchase date, serial #, type of unit and part or parts  
requested.  
SUBJECT TO CHANGE.  
DISTRIBUTORS:  
Western Australia  
Eastern Australia  
AUSTRALIAN HEATING DISTRIBUTORS  
31 CLUNE STREET  
FIREPLACE PRODUCTS AUSTRALIA PTY. LTD.  
21-23 SOUTH LINK BLVD.  
BAYSWATER, WA 6053  
DANDENONG, VIC 3175  
SERVICE AGENTS:  
HEARTH HOUSE SERVICE  
31 CLUNE STREET  
BAYSWATER, WA 6053  
NOTE: PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION  
INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY  
A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES.  
Regency® P36-4 Gas Log Fireplace  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Printed in Canada  
© Copyright 2007, FPI Fireplace Products International Ltd. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Q See Baby Monitor QSDB8209C User Guide
Ramsey Electronics Car Satellite TV System HR20 User Guide
RCA Car Video System DRC220N User Guide
RCA Flat Panel Television RLC2609 User Guide
Remington Electric Shaver BHT 600 User Guide
RIDGID Saw TS2400LS User Guide
Roberts Radio Radio CRD 39 User Guide
Samsung Portable DVD Player DVD L300WDEU User Guide
Sanyo Headphones SHH9508 User Guide
Sanyo Projector PLV WF20 User Guide