Owners &
Installation Manual
Freestanding Woodstoves
Medium Freestanding Woodstove
withoptionalGoldLegs.
Medium Freestanding Step Stove
withPedestalBase.
MODELS: F1100S F2100M F3100L S2100M S3100L
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
908-288
FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
01/13/03
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
THE REGENCY FREESTANDING STOVE
SAFETYLABEL
Door Handle ...................................................................... 17
Glass Installation .............................................................. 17
Optional Accessories
Small Freestanding Stove F1100S ..................................... 4
Medium Freestanding Stove F2100M ................................. 5
Large Freestanding Stove F3100L ..................................... 6
Medium Freestanding Step Stove S2100M ........................ 7
Large Freestanding Step Stove S3100L............................. 8
- Pedestal Ash Drawer Kit .......................................... 17
- Bottom Shield Ashdrawer Kit ................................... 17
- Blower/Fan ............................................................... 18
- Blower/Fan Wiring Diagram .................................... 18
INSTALLATION
OPERATINGINSTRUCTIONS
Residential Installation ....................................................... 9
Room Air .............................................................................. 9
Modular Installation Options ............................................... 9
Minimum Clearance to Combustibles.............................. 10
Residential "C" Vent Single Wall....................................... 10
Residential Close Clearance ........................................... 10
Mobile Home Close Clearance ........................................ 10
Minimum Alcove Clearances ............................................ 11
Floor Protection ................................................................. 11
Stove Assembly Prior to Installation ................................. 12
Airmate Assembly ............................................................. 12
Rear Heat Deflector Assembly.......................................... 12
Side Shield Adjustment for the S2100 & S3100 ............... 12
Pedestal Assembly ........................................................... 12
Leg and Bottom Shield Assembly .................................... 13
Chimney & Connector Installation .................................... 13
Flue Height Table .............................................................. 14
Recommended Height for Woodstove Flue ..................... 14
Mobile Home Installation .................................................. 14
Listed Components for Mobile Home Installation
Operating Instructions ....................................................... 19
Draft Control ...................................................................... 19
First Fire............................................................................. 19
Fan Operation.................................................................... 19
Ash Disposal ..................................................................... 20
- Ash Drawer Operating Guidelines........................... 20
Safety Guidelines .............................................................. 20
MAINTENANCE
Maintenance ...................................................................... 20
Creosote ............................................................................ 21
- Ways to Prevent & Keep Units Free of Creosote ..... 21
Maintenance of Gold Doors .............................................. 21
Latch Adjustment............................................................... 21
Door Gasket ...................................................................... 21
Glass Maintenance ........................................................... 21
- Glass Replacement ................................................. 21
Parts List - F1100, F2100, F3100 ..................................... 22
Parts List - S2100, S3100 ................................................. 23
Parts List - Pedestal, Bottom Shield and Legs ................ 24
Parts List - Firebrick .......................................................... 25
- U.S. Installations ...................................................... 15
- Canadian Installations............................................. 15
Brick Flue Baffle & Secondary Air Tube Installation
- Large Stove F3100L & S3100L ................................ 15
- Medium Stove F2100M/S2100 ................................. 16
- Small Stove F1100S ................................................ 16
Brick Installation ................................................................ 17
WARRANTY
Warranty ............................................................................. 27
3
Regency Freestanding Woodstove
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY LABEL
This is a copy of the label that accompanies of the back of the stove. We have printed a copy
each Regency Small Freestanding Woodstove of the contents here for your review.
(F1100S). It is located in the upper right corner
NOTE: Regency units are constantly being
improved.Checkthelabelontheunitandifthere
is a difference, the label on the unit is the correct
one.
DO NOT REMOVE THIS LABEL
LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO
SUITABLE FOR MOBILE HOME INSTALLATION
100
MODEL: REGENCY SMALL FREESTANDING STOVE - F1100S
TESTED TO: CSA B366.2 / ULC S627 / UL 1482 REPORT NO.6621 (MAY 1993)
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND
OPERATINGINSTRUCTIONS. CONTACTLOCALBUILDINGORFIREOFFICIALSABOUTRESTRICTIONS
AND INSTALLATION INSPECTION IN YOUR AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG
BLACKOR26MSGBLUEDSTEELCONNECTORWITHLISTEDFACTORY-BUILTCHIMNEYSUITABLEFOR
USE WITH SOLID FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED
FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY
F1100S WITHOUT
F1100S WITH
AIRMATE SHIELD
CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A
AIRMATE SHIELD
BACKWALL
B
CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
E
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
A
D
F1100S WITH AIRMATE SHIELD
F1100S WITHOUT AIRMATE SHIELD
MEASURE
FLUE
MEASURE
FROM
FLUE
CENTER-LINE
FROM
HEATER
CENTER-LINE
HEATER
RESIDENTIAL INSTALLATION USING
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
BACKWALL
SINGLE WALL CONNECTOR
SIDEWALL
BACKWALL B 265 mm / 10.5in E 430 mm / 17 in
CORNER C 280 mm / 11 in F 585 mm / 23 in
A 380 mm /15 in D 685 mm / 27 in
SIDEWALL
A 330 mm / 13 in D 635 mm / 25 in
H
J
BACKWALL B 280 mm / 11 in E 445 mm / 17.5in
CORNER C 205 mm / 8 in F 510 mm / 20 in
G
G
I
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
SIDEWALL
A 280 mm / 11 in D 585 mm / 23 in
SIDEWALL
A 330 mm / 13 in D 635 mm / 25 in
BACKWALL B 150 mm / 6 in E 320 mm / 12.5in
BACKWALL B 125 mm / 5 in E 290 mm / 11.5in
ADJACENT WALL
C
CORNER
C 150 mm / 6 in F 460 mm / 18 in
CORNER
C 230 mm / 9 in F 535 mm / 21 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
SIDEWALL
BACKWALL B 125 mm / 5 in E 290 mm / 11.5in
CORNER C 75 mm / 3 in F 380 mm / 15 in
A 230 mm / 9 in D 535 mm / 21 in
SIDEWALL
BACKWALL B 125 mm / 5 in E 290 mm / 11.5in
CORNER C 125 mm / 5 in F 430 mm / 17 in
A 345 mm / 13.5in D 650 mm / 25.5in
F
M
BACK
FLOOR
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - ALCOVE
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - ALCOVE
L
PROTECTION*
K
L
M
405 mm / 16 in
150 mm / 6 in
150 mm / 6 in
SIDEWALL
G 330 mm / 13 in
I
635 mm / 25 in
290 mm / 11.5in
SIDEWALL
G 280 mm / 11 in
I
585 mm / 23 in
345 mm / 13.5in
BACKWALL H 125 mm / 5 in
J
BACKWALL H 180 mm / 7 in
J
K
FRONT
* In Canada, floor protection must
extend 18" to the front and 8" to
each side of the stove.
MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.
MAXIMUM ALCOVE DEPTH 915 MM / 36 IN.
FORUSEWITHSOLIDWOODFUELONLY. USEOFOTHERFUELSMAYDAMAGEHEATERANDCREATEAHAZARDOUSCONDITION. DONOTOBSTRUCT
COMBUSTIONAIROPENINGS. OPERATEONLYWITHFIREBRICKSINPLACE. OPERATEONLYWITHDOORCLOSED-OPENFEEDDOORTOFEEDFIRE
ONLY. DONOTUSEGRATEORELEVATEFIRE. BUILDWOODFIREDIRECTLYONHEARTH. DONOTOVERFIRE-IFHEATERORCHIMNEYCONNECTOR
GLOWSYOUAREOVERFIRING. INSPECTANDCLEANCHIMNEYANDCONNECTORFREQUENTLY. UNDERCERTAINCONDITIONSOFUSECREOSOTE
BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH
NEOCERAM GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO
THE FRONT AND SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM:
SECURITY MODEL S2100, ICC EXCEL 2100 .
IN USA:
LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA
VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS
SECURITYMODELS2100ORMODELASHT,SELKIRKMODELSSII,OLIVERMACLEODPROJET3103,SIMPSONDURAPLUS,GSWMODELSCORMETAL-
FAB TEMP/GUARD, AMERI-TEC HS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.
MANUFACTURED BY: FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4
MADE IN CANADA
UNITED STATES ENVIRONMENTAL
PROTECTION AGENCY
CERTIFIED TO COMPLY WITH JULY 1990,
PARTICULATE EMISSION STANDARDS.
CAUTION
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHINGANDFURNITUREAWAY. CONTACTMAYCAUSE
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
WD
908-281 01/03
Regency Freestanding Woodstove
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY LABEL
This is a copy of the label that accompanies corner of the back of the stove. We have printed
each Regency Medium Freestanding Wood- a copy of the contents here for your review.
stove (F2100M). It is located in the upper right
NOTE: Regency units are constantly being
improved.Checkthelabelontheunitandifthere
is a difference, the label on the unit is the correct
one.
DO NOT REMOVE THIS LABEL
101
LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO
SUITABLE FOR MOBILE HOME INSTALLATION
MODEL: REGENCY MEDIUM FREESTANDING STOVE - F2100M
TESTED TO: CSA B366.2 / ULC S627 / UL 1482 REPORT NO.6622 (FEB.1993)
INSTALLANDUSEONLYINACCORDANCEWITHTHEMANUFACTURER'SINSTALLATIONANDOPERATING
INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR
26 MSG BLUED STEEL CONNECTOR WITH LISTED FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH
SOLID FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED
FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY
F2100M WITHOUT
CONNECTORTHROUGHCOMBUSTIBLEWALLORCEILING. DONOTCONNECTTHISUNITTOACHIMNEY
F2100M WITH
AIRMATE SHIELD AIRMATE SHIELD
FLUE SERVING ANOTHER APPLIANCE.
BACKWALL
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
B
E
F2100M WITH AIRMATE SHIELD
F2100M WITHOUT AIRMATE SHIELD
A
D
MEASURE
FROM
FLUE
CENTER-LINE
MEASURE
FROM
FLUE
CENTER-LINE
HEATER
HEATER
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
BACKWALL
SIDEWALL
A 430 mm / 17 in D 735mm / 29in
SIDEWALL
A 355 mm / 14 in D 660 mm / 26 in
BACKWALL B 280 mm / 11 in E 445mm / 17.5in
H
J
BACKWALL B 255 mm / 10 in E 420 mm / 16.5 in
CORNER
C 230 mm / 9 in F 535 mm / 21 in
CORNER
C 190 mm / 7.5 in F 510 mm / 20 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
G
G
I
SIDEWALL
A 405 mm / 16 in D 725 mm / 28.5in
SIDEWALL
A 460 mm / 18 in D 775 mm / 30.5 in
BACKWALL B 215 mm / 8.5in E 395 mm / 15.5in
BACKWALL B 215 mm / 8.5in E 395 mm / 15.5in
CORNER
C 190 mm / 7.5in F 510 mm / 20 in
CORNER
C 215 mm / 8.5in F 535 mm / 21 in
ADJACENT WALL
C
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
SIDEWALL
BACKWALL B 115 mm / 4.5 in E 290 mm / 11.5 in BACKWALL B 180 mm / 7 in E 355 mm / 14 in
CORNER C 150 mm / 6 in F 445 mm / 17.5 in CORNER C 215 mm / 8.5in F 535 mm / 21 in
A 255 mm / 10 in D 550 mm / 22.5 in SIDEWALL
A 355 mm / 14 in D 675 mm / 26.5in
F
M
BACK
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - ALCOVE
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - ALCOVE
FLOOR
PROTECTION*
L
SIDEWALL
BACKWALL H 115 mm / 4.5in
G 255 mm / 10 in
I
J
570 mm / 22.5in SIDEWALL
290 mm / 11.5in BACKWALL H 180 mm / 7 in
G 355 mm / 14 in
I
J
675 mm / 26.5in
355 mm / 14 in
K
L
M
405 mm / 16 in
150 mm / 6 in
150 mm / 6 in
K
FRONT
MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.
MAXIMUM ALCOVE DEPTH 915 MM / 36 IN.
* In Canada, floor protection must
extend 18" to the front and 8" to
each side of the stove.
FORUSEWITHSOLIDWOODFUELONLY. USEOFOTHERFUELSMAYDAMAGEHEATERANDCREATEAHAZARDOUSCONDITION. DONOTOBSTRUCT
COMBUSTIONAIROPENINGS. OPERATEONLYWITHFIREBRICKSINPLACE. OPERATEONLYWITHDOORCLOSED-OPENFEEDDOORTOFEEDFIRE
ONLY. DONOTUSEGRATEORELEVATEFIRE. BUILDWOODFIREDIRECTLYONHEARTH. DONOTOVERFIRE-IFHEATERORCHIMNEYCONNECTOR
GLOWSYOUAREOVERFIRING. INSPECTANDCLEANCHIMNEYANDCONNECTORFREQUENTLY. UNDERCERTAINCONDITIONSOFUSECREOSOTE
BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH
NEOCERAM GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO
THE FRONT AND SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM:
SECURITY MODEL S2100, ICC EXCEL 2100.
IN USA:
LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA
VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS
SECURITYMODELS2100ORMODELASHT,SELKIRKMODELSSII,OLIVERMACLEODPROJET3103,SIMPSONDURAPLUS,GSWMODELSCORMETAL-
FAB TEMP/GUARD, AMERI-TEC HS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.
MANUFACTURED BY: FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4
MADE IN CANADA
UNITED STATES ENVIRONMENTAL
PROTECTION AGENCY
CERTIFIED TO COMPLY WITH JULY 1990,
PARTICULATE EMISSION STANDARDS.
CAUTION
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHINGANDFURNITUREAWAY. CONTACTMAYCAUSE
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
WD
908-282
rev. 01/03
5
Regency Freestanding Woodstove
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY LABEL
of the back of the stove. We have printed a
copy of the contents here for your review.
This is a copy of the label that accompanies
each Regency Large Freestanding Woodstove
(F3100L). It is located in the upper right corner
NOTE: Regency units are constantly being
improved.Checkthelabelontheunitandifthere
is a difference, the label on the unit is the correct
one.
DO NOT REMOVE THIS LABEL
102
LISTED SPACE HEATER, SOLID FUEL TYPE, SUITABLE FOR
MOBILE HOME INSTALLATION
MODEL:
REGENCY LARGE FREESTANDINGSTOVE-F3100L
TESTEDTO:
CSA B366.2 / ULC S627 / UL 1482 REPORT NO.6623 (MAY 93)
INSTALLANDUSEONLYINACCORDANCEWITHTHEMANUFACTURER'SINSTALLATIONANDOPERAT-
ING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATIONINSPECTIONINYOURAREA. USE150MM(6IN.)DIAMETERMINIMUM24MSGBLACKOR
26MSG BLUEDSTEEL CONNECTORWITHLISTEDFACTORY-BUILT CHIMNEY SUITABLE FORUSE WITH
SOLID FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED
FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY
CONNECTORTHROUGHCOMBUSTIBLEWALLORCEILING. DONOTCONNECTTHISUNITTOACHIMNEY
F3100L WITHOUT
AIRMATE SHIELD
F3100L WITH
AIRMATE SHIELD
BACKWALL
FLUE SERVING ANOTHER APPLIANCE.
B
E
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
A
D
F3100L WITH AIRMATE SHIELD
F3100L WITHOUT AIRMATE SHIELD
MEASURE
FROM
FLUE
CENTER-LINE
MEASURE
FROM
FLUE
CENTER-LINE
HEATER
HEATER
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
SIDEWALL
SIDEWALL A 460 mm / 18 in D 810 mm / 32 in
BACKWALL B 305 mm / 12 in E 470 mm / 18.5in
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
A 510 mm / 20 in D 860 mm / 34 in
BACKWALL B 355 mm / 14 in E 520 mm / 20.5 in
BACKWALL
H
J
CORNER
C 215 mm / 8.5in F 560 mm / 22 in
C 265 mm / 10.5in F 610 mm / 24 in
CORNER
G
G
I
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
SIDEWALL
A 460 mm / 18 in D 810 mm / 32 in
SIDEWALL
A 510 mm / 20 in D 860 mm / 34 in
ADJACENT WALL
C
BACKWALL B 240 mm / 9.5in E 405 mm / 16 in
CORNER
BACKWALL B 305 mm / 12 in E 470 mm / 18.5in
CORNER
C 255 mm / 10 in F 595 mm / 23.5in
C 255 mm / 10 in F 595 mm / 23.5in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
SIDEWALL
F
A 405 mm / 16 in D 760 mm / 30 in SIDEWALL
A 510 mm / 20 in D 860 mm / 34 in
M
BACK
BACKWALL B 240 mm / 9.5in E 405 mm / 16 in BACKWALL B 305 mm / 12 in E 470 mm / 18.5in
FLOOR
L
CORNER
C 215 mm / 8.5in F 560 mm / 22 in CORNER
C 215 mm / 8.5in F 560 mm / 22 in
PROTECTION*
405 mm / 16 in
150 mm / 6 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - ALCOVE
K
L
M
ALCOVEINSTALLATION
REQUIRES AIRMATE SHIELD
K
FRONT
SIDEWALL
G 405 mm / 16 in
I
760 mm / 30 in
405 mm / 16 in
150 mm / 6 in
BACKWALL H 240 mm / 9.5in
J
* In Canada, floor protection must
extend 18" to the front and 8" to
each side of the stove.
MINIMUM CLEARANCE BETWEEN HORIZONTAL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERIALS - 460 MM (18 IN.). CLEARANCE MAY BE
REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS.
COMBUSTIBLEFLOORMUSTBEPROTECTEDBYNON-COMBUSTIBLEMATERIALEXTENDINGBENEATHTHEHEATERANDTOTHEFRONTANDSIDES
AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
FORUSEWITHSOLIDWOODFUELONLY. USEOFOTHERFUELSMAYDAMAGEHEATERANDCREATEAHAZARDOUSCONDITION. DONOTOBSTRUCT
COMBUSTIONAIROPENINGS. OPERATEONLYWITHFIREBRICKSINPLACE. OPERATEONLYWITHDOORCLOSED-OPENFEEDDOORTOFEEDFIRE
ONLY. DONOTUSEGRATEORELEVATEFIRE. BUILDWOODFIREDIRECTLYONHEARTH. DONOTOVERFIRE-IFHEATERORCHIMNEYCONNECTOR
GLOWSYOUAREOVERFIRING. INSPECTANDCLEANCHIMNEYANDCONNECTORFREQUENTLY. UNDERCERTAINCONDITIONSOFUSECREOSOTE
BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH
NEOCERAM GLASS.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM:
SECURITY MODEL S2100, ICC EXCEL 2100.
IN USA:
LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA
VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS
SECURITYMODELS2100ORMODELASHT,SELKIRKMODELSSII,OLIVERMACLEODPROJET3103,SIMPSONDURAPLUS,GSWMODELSCORMETAL-
FAB TEMP/GUARD, AMERI-TEC HS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.
MANUFACTURED BY: FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4
MADE IN CANADA
UNITED STATES ENVIRONMENTAL
PROTECTION AGENCY
CERTIFIED TO COMPLY WITH JULY 1990,
PARTICULATE EMISSION STANDARDS.
CAUTION
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHINGANDFURNITUREAWAY. CONTACTMAYCAUSE
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
WD
908-351
01/03
Regency Freestanding Woodstove
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY LABEL
Thisisacopyofthelabelthataccompanieseach
RegencyMediumFreestandingStepWoodstove
(S2100M). It is located in the upper right corner
of the back of the stove. We have printed a copy
of the contents here for your review.
NOTE: Regency units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
107
DO NOT REMOVE THIS LABEL
107
LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO
SUITABLE FOR MOBILE HOME INSTALLATION
MODEL: REGENCY MEDIUM FREESTANDING STEP STOVE - S2100M
CSA B366.2 / ULC S627 / UL 1482 REPORT NO.6622 (FEB.1993)
TESTEDTO:
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.
CONTACTLOCALBUILDINGORFIREOFFICIALSABOUTRESTRICTIONSANDINSTALLATIONINSPECTIONINYOURAREA. USE
150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED FACTORY-BUILT
CHIMNEYSUITABLEFORUSEWITHSOLIDFUELSORMASONRYCHIMNEY.
SEELOCALBUILDINGCODEANDMANUFACTURER'SINSTRUCTIONSFORPRECAUTIONSREQUIREDFORPASSINGACHIMNEY
THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE WALL OR
CEILING. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
S2100M
S2100MINIMUMCLEARANCESTOCOMBUSTIBLEMATERIALS
BACKWALL
B
FLOORPROTECTION*
MEASURE
FROM
FLUE
CENTER-LINE
HEATER
E
M
BACK
K
L
M
405 mm
150 mm
150 mm
/
/
/
16 in
6
6
in
in
A
D
L
RESIDENTIALINSTALLATIONUSINGSINGLEWALLCONNECTOR
SIDEWALL
BACKWALL B 255 mm / 10 in
CORNER C 150 mm / 6 in
A 355 mm / 14 in
D
E
F
660 mm / 26 in
420 mm / 16.5 in
445 mm / 17.5 in
* In Canada, floor protec-
tion must extend 18" to
the front and 8" to each
side of the stove.
K
FRONT
BACKWALL
INSTALLATION USING LISTED DOUBLE WALL CONNECTOR - MOBILE HOME
H
J
SIDEWALL
BACKWALL B 215 mm / 8.5 in
CORNER C 190 mm / 7.5 in
A 405 mm / 16 in
D
E
F
725 mm / 28.5 in
395 mm / 15.5 in
510 mm / 20 in
MINIMUM ALCOVE CEILING HEIGHT:
2.15 M / 7 FT
G
G
I
INSTALLATION USING LISTED DOUBLE WALL CONNECTOR -
RESIDENTIALCLOSECLEARANCE
MAXIMUM ALCOVE DEPTH:
915 MM / 36 IN.
SIDEWALL
BACKWALL B 115 mm / 4.5 in
CORNER C 190 mm / 7.5 in
A 255 mm / 10 in
D
E
F
550 mm / 22.5 in
290 mm / 11.5 in
510 mm / 20 in
ADJACENT WALL
C
MINIMUM CLEARANCES FOR HORIZONTAL
CONNECTORTOCEILING:
455 MM / 18"
INSTALLATION USING LISTED DOUBLE WALL CONNECTOR - ALCOVE
SIDEWALL
BACKWALL H 115 mm / 4.5 in
G 255 mm / 10 in
I
J
570 mm / 22.5 in
290 mm / 11.5 in
F
THESPACEBENEATHTHEHEATERMUST
NOTBEOBSTRUCTED.OPERATEONLY
WITHFIREBRICKSINPLACE.
FORUSEWITHSOLIDWOODFUELONLY. USEOFOTHERFUELSMAYDAMAGEHEATERANDCREATEAHAZARDOUSCONDITION. DONOTOBSTRUCT
COMBUSTIONAIROPENINGS. OPERATEONLYWITHFIREBRICKSINPLACE. OPERATEONLYWITHDOORCLOSED-OPENFEEDDOORTOFEEDFIREONLY.
DONOTUSEGRATEORELEVATEFIRE. BUILDWOODFIREDIRECTLYONHEARTH. DONOTOVERFIRE-IFHEATERORCHIMNEYCONNECTORGLOWSYOU
AREOVERFIRING. INSPECTANDCLEANCHIMNEYANDCONNECTORFREQUENTLY. UNDERCERTAINCONDITIONSOFUSECREOSOTEBUILDUPMAYOCCUR
RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH NEOCERAM GLASS.
COMBUSTIBLEFLOORMUSTBEPROTECTEDBYNON-COMBUSTIBLEMATERIALEXTENDINGBENEATHTHEHEATERANDTOTHEFRONTANDSIDESAS
INDICATEDORTOTHENEARESTPERMITTEDCOMBUSTIBLEMATERIAL.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS
COMPONENTSREQUIREDFORMOBILEHOMEINSTALLATION:OUTSIDEAIRKITANDONEOFTHEFOLLOWINGDOUBLEWALLCONNECTOR
INCANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM:
SECURITY MODEL S2100, ICC EXCEL 2100.
INUSA:
LISTEDDOUBLEWALLCONNECTORSSECURITYMODELDP,SELKIRKMODELDS,OLIVERMACLEODPROVENTPV,SIMPSONDURAVENT
MODELDVL, GSWSUPERPIPE6, METAL-FABDOUBLEWALL. CONNECTEDTOONEOFTHEFOLLOWINGCOMPATIBLECHIMNEYSYSTEMSSECURITY
MODELS2100ORMODELASHT, SELKIRKMODELSSII, OLIVERMACLEODPROJET3103, SIMPSONDURAPLUS, GSWMODELSCORMETAL-FABTEMP/
GUARD, AMERI-TEC HS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.
MANUFACTURED BY: FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4
MADE IN CANADA
UNITED STATES ENVIRONMENTAL
PROTECTION AGENCY
CERTIFIED TO COMPLY WITH JULY 1990,
PARTICULATE EMISSION STANDARDS.
CAUTION
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHINGANDFURNITUREAWAY. CONTACTMAYCAUSE
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
WD
908-733
rev. 01/03
7
Regency Freestanding Woodstove
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY LABEL
This is a copy of the label that accompanies
eachRegencyLargeFreestandingStepWood-
stove (S3100L). It is located in the upper right
corner of the back of the stove. We have printed
a copy of the contents here for your review.
NOTE: Regency units are constantly being
improved.Checkthelabelontheunitandifthere
isadifference, thelabelontheunitisthecorrect
one.
Regency Freestanding Woodstove
8
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
chimney must be listed as suitable for use
with solid fuels. For other types of chim-
neys check with your local building code
officials. Do not confuse a chimney with a
type “B” Venting System used for gas
appliances as suitable for a wood burning
appliance. For Mobile Home installations
refer to that section on page 14.
your local building authority.
RESIDENTIAL
INSTALLATION
12) A chimney connector cannot pass through
an attic or roof space, closet or similar
concealed space, or a floor, ceiling, wall or
partition of combustible construction. In
Canada, if passage through a wall, or par-
tition of combustible construction is de-
sired, the installation shall conform to CAN/
CSA-B365, InstallationCodeforSolid-Fuel-
Burning Appliances and Equipment.
1) Read all instructions before installing your
Regency Stove. Install and use only in
accordance with these installation and
operating instructions. Be aware that local
Codes and Regulations may override some
items in this manual. Check with your local
inspector.
6) Mark the location of the pedestal base or
legs on the floor, then move the stove aside
and mark the position of the floor protector.
2) Select a position for your Regency Stove.
Consult the minimum clearance chart for
your model and set the stove in place. For
close clearance installation use listed dou-
ble wall connector systems (see page 15).
13) Your Regency Woodstove is not to be
7) The floor protector must be of non-combus-
tible material and must extend 16" in front of
the door opening and 6" to the sides and
rear of the unit. Some areas may require a
larger size floor protector. See your local
inspector. For outside air installation refer
to Mobile Home installation instructions on
page 14.
connected to any air distribution duct.
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
3) To insure vertical alignment, suspend a
plumb bob from the ceiling over the exact
center of your stove flue and mark a spot on
the ceiling to indicate the center of the
chimney.
ROOM AIR
NOTE: In Canada, floor protection must
extend 18" to the front and 8" to
each side of the stove.
IMPORTANT
For installation using room air for combustion,
remove knockout from the pedestal, and/or
from the bottom if using a heat shield.
4) Checkthattheareaabovetheceilingisclear
for cutting. Re-confirm the clearance from
the stove to combustibles to insure that they
are within the prescribed limits.
8) When the floor protection is complete, po-
sition the stove with the flue collar centered
under the installed chimney.
Mobile home installations require the use of
outside air.
5) Install chimney according to chimney man-
ufacturers instructions. The performance
of your woodstove is governed to a very
large part by the chimney system. Too short
a chimney can cause difficult start-up, dirty
glass, backsmoking when door is open, and
even reduced heat output. Too tall a chim-
ney may prompt excessive draft which can
result in very short burn times and exces-
sive heat output. The use of an inexpensive
flue pipe damper may be helpful in reducing
excessive draft.
9) In seismically active areas, Regency rec-
ommends that your unit is secured to the
floor by using the bolt down holes inside the
pedestal (the same ones used in Mobile
Home installations).
On pedestal units there are two locations where
outside air may be adapted to the unit. If using
the bottom of the pedestal, do not remove
knockout from the rear of the pedestal. Only
remove rear knockout if outside air will be
brought in from the rear.
10) For residential installations using "C" Vent
(single wall) the chimney connector must
be at least 24 gauge steel. Do not use
galvanized pipe. For Mobile Home installa-
tion refer to the Mobile Home installation
instructions on page 14.
On leg units outside air can only be brought in
from the bottom of the heat shield.
Note: Once the knockout is removed
there are two tabs remaining. Bend
both tabs out for ease of installa-
tion when attaching outside air.
CAUTION:Thechimneyshouldbethesame
size as the flue outlet on the stove. The
11) Do not connect this unit to a chimney serv-
ing another appliance unless approved by
MODULAR INSTALLATION OPTIONS
The following items are required when assembling your Regency Stove. F1100, F2100, and F3100 units - the Rear Heat Deflector is supplied with
the stove, but if you choose not to use it you must use the Airmate instead.
Things to consider when choosing options:
Modular Part
Clearances are different. See the chart on pages 10 and 11. Generally you can get closer clearances with the airmate
than with the rear heat deflector.
F1100, F2100 and
F3100only:
Airmate OR
Rear Heat Deflector
Convection heat with Airmate vs. Radiant Heat with Rear Heat Deflector. The airmate pushes heat forward and into
the room, the rear heat deflector deflects the heat upward. See installation instructions on pages 11 and 12.
There are no performance differences with either the pedestal or legs. It is primarily a personal preference. Legs
can be either painted steel, painted cast, or gold plated cast.
(all units)
Pedestal OR
Legs
Leg installation requires the bottom shield. See installation instructions on page 13.
OPTIONS: These can be installed at time of installation or added later:
Modular Option
Things to consider when choosing options
Adding the blower will increase the area heated by the stove, it can move warm air beyond the room where the stove
is installed. Installation instructions on page 18.
Blower/Fan
Adding the Ash Drawer Kit makes cleaning ashes out of the stove easier and cleaner. Installation instructions on page
17.
Ash Drawer Kit
9
Regency Freestanding Woodstove
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Please read the section below carefully as clearances depend on whether the airmate or the
rear heat deflector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner,
and from the rear heat shield to a back wall.
Residential Installation “C” Vent (Single Wall)
Unit
From Unit
From Corner From Flue Center-line
A
B
C
D
E
F
Small F1100S
with Airmate
13"
15"
11"
8"
25"
27"
17.5"
17"
20"
23"
with Rear Deflector
10.5"
11"
Medium F2100M with Airmate
with Rear Deflector
14"
17"
10"
11"
6"
9"
26"
29"
16.5"
17.5"
17.5"
21"
Medium S2100M Step Stove
14"
10"
6"
26"
16.5"
17.5"
Large F3100L
with Airmate
with Rear Deflector
18"
20"
12"
14"
8.5"
10.5"
32"
34"
18.5"
20.5"
22"
24"
Large S3100L Step Stove
18"
12"
8.5"
32"
18.5"
22"
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove
collar to the ceiling level.
Unit
From Unit
B
From Corner From Flue Center-line
A
C
D
E
F
Small F1100S
with Airmate
9"
5"
5"
3"
5"
21"
11.5"
11.5"
15"
17"
with Rear Deflector
13.5"
25.5"
Medium F2100M with Airmate
with Rear Deflector
10"
14"
4.5"
7"
7.5"
8.5"
22.5"
26.5"
11.5"
14"
20"
21"
Medium S2100M Step Stove
10"
4.5"
7.5"
22.5"
11.5"
20"
Large F3100L
with Airmate
with Rear Deflector
16"
20"
9.5"
12"
8.5"
8.5"
30"
34"
16"
18.5"
22"
22"
Large S3100L Step Stove
16"
9.5"
8.5"
30"
16"
22"
Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)
Unit
From Unit
B
From Corner From Flue Center-line
A
C
D
E
F
Small F1100S
with Airmate
11"
13"
6"
5"
6"
9"
23"
25"
12.5"
11.5"
18"
21"
with Rear Deflector
Medium F2100M with Airmate
with Rear Deflector
16"
18"
8.5"
8.5"
7.5"
8.5"
28.5"
30.5"
15.5"
15.5"
20"
21"
Medium S2100M Step Stove
16"
8.5"
7.5"
28.5"
15.5"
20"
Large F3100L
with Airmate
18"
20"
9.5"
12"
10"
10"
32"
34"
16"
18.5"
23.5"
23.5"
with Rear Deflector
Large S3100L Step Stove
18"
9.5"
10"
32"
16"
23.5"
Regency Freestanding Woodstove
10
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Minimum Alcove Clearance to Combustible Materials
The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 84"
Maximum depth of alcove - 36"
From
Unit
From Flue
Center-line
Min.
Min.Hearth
to Rear Wall
Unit
Width
K
G
H
I
J
L
Small F1100S
with Airmate
11"
13"
7"
5"
23"
25"
13.5"
11.5"
46"
50"
39"
37"
with Rear Deflector
Medium F2100M
with Airmate
with Rear Deflector
10"
14"
4.5"
7"
22"
26.5"
11.5"
14"
44"
52"
41.5"
44"
Medium S2100M Step Stove
Large F3100L with Airmate
10"
16"
4.5"
9.5"
22"
30"
11.5"
16"
44"
60"
41.5"
46.5"
with Rear Deflector
(not approved for Alcove)
Large S3100L Step Stove
16" 9.5" 30"
16"
60"
46.5"
Floor Protection
A combustible floor must be protected by a non-combustible material (like tile,
concrete board, or certified to UL-1618 or as defined by local codes) extending
beneath the heater and a minimum of 6" from each side and minimum 16" from
the front face of the stove and minimum 6" (or the rear clearance to
combustibles whichever is smaller) from the rear of the stove.
Minimum Overall Width (X) of Floor
Protector for all installations:
Small Stove
F1100S
F2100M
S2100M
F3100L
S3100L
36"
36"
36"
40"
40"
MediumStove
Medium Step Stove
Large Stove
Large Step Stove
NOTE: In Canada, floor protection must extend 18" to the front and 8" to each side of the stove.
Minimum Overall Depth (Y) of Floor Protector
Residential
"C" Vent
Residential
Mobile Home
Alcove
Y
Unit
Close Clearance
Close Clearance
Y
Z
Y
Z
Y
Z
Z
Small F1100S
with Airmate
38"
38"
6"
6"
37"*
37"*
5"
5"
38"
6"
5"
38"
6"
5"
with Rear Deflector
37"*
37"*
Medium F2100M
with Airmate
with Rear Deflector
43"
43
6"
6"
41.5"*
43"
4.5"
6"
43"
43"
6"
6"
41.5"*
43"
4.5"
6"
Medium S2100M Step Stove
43"
6"
41.5"*
4.5"
43"
6"
41.5"*
4.5"
Large F3100L with Airmate
43"
43"
6"
6"
43"
43"
6"
6"
43"
43"
6"
6"
43"
n/a
6"
n/a
with Rear Deflector
Large S3100L Step Stove
43"
6"
43"
6"
43"
6"
43"
6"
*The rear clearance to combustibles is less than 6", for corner installations the rear corners may be angled to take advantage of the closer clearances.
11
Regency Freestanding Woodstove
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Rear Heat Deflector Assembly for
F1100, F2100, and F3100
PedestalAssembly
STOVE ASSEMBLY
PRIOR TO
Small
850-115
850-215
850-315
Medium
Large
Small & Medium
Large
815-555
815-556
INSTALLATION
All units require either the pedestal or 4 legs
attached to the base. The F1100, F2100, and
F3100 stoves require either the Airmate or Rear
Heat Deflector on top of the stove. Clearances
to combustible materials vary depending on
whether the airmate or rear heat deflector is
installed, so be sure to check the clearance
information on pages 10 and 11.
1) For easier assembly, tip the stove on its
back(ontoasoftsurfacetopreventscratch-
ing).
The rear heat deflector is supplied with the
stove and must be installed unless the optional
airmate has been selected. It stops the heat
radiated from the flue collar from overheating
the rear wall. The rear heat deflector is installed
on top of the rear heat shield, as shown in
diagram 4.
Hint: If you have chosen the Ash Drawer
option, remove the ash dump cover plates
before attaching the pedestal. See page 17
"Ashdrawer Kit Installation".
2) Remove the blanking plate if
a) you are not installing outside combus-
tion air or
Airmate Assembly for F1100,
F2100, and F3100
b) outside air is to be brought in from the
rear of the stove.
Small & Medium
Large
850-105
850-305
3) Unscrew the 4 bolts in the under-side of the
stove. Align the holes in the corners of the
pedestal top with the corresponding holes
in the base of the stove. Fasten using a bolt
and washer for each corner.
1) The airmate sits on top of the stove with the
slots in the sides fitting over the curved
deflector on the rear stove top. See diagram
1. Discard the Rear Heat Deflector that is
supplied with the unit, it is not required if the
airmate is installed.
2) Centertheairmateandpushitforwardtothe
front of the stove. The back of the airmate
should be level with the back and sides of
the rear heat shield. See diagrams 2 & 3.
Diagram 4
S2100M & S3100L Side Shield
Adjustment
The left and right side shields are lowered for
shipping and handling. It allows for a handhold
onthetopofthestove.BeforeplacingintheStep
Stove in its final position, the side shields must
be raised.
Loosen the screws on the rear on the stove (3
per side), slide the side panel up as far as
possible and then secure by tightening the
screws.
Diagram 1
4) Push the Regency logo
into the two holes
in the front bot-
tom left corner
of the pedestal
cover plate.
Diagram 2
Note: Any paint touch up should be done
prior to placing logo on pedestal.
5) If not using ash drawer, then cover plate must
be installed. If using ash drawer, then disre-
gard cover plate.
Diagram 3
Regency Freestanding Woodstove
12
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
8) To complete your chimney installation, in-
stall the double wall connector pipe from
the stove’s flue collar to the chimney sup-
port device.
Leg and Bottom Shield Assembly
STEP BY STEP
CHIMNEY AND
CONNECTOR
Bottom Shield
Small
Medium
Large
850-121
850-221
850-321
9) If you are using a horizontal connector, the
chimney connector should be as high as
possible while still maintaining the 18" min-
imum distance from the horizontal connec-
tor to the ceiling.
INSTALLATION:
Legs (set of 4)
Note: These are a generic set of chim-
ney installation instructions. Al-
ways follow the manufacturers
own instructions explicitly. Check
Table 1 on page 14 for the Mini-
mum Recommended Flue Heights.
Steel - Painted Black 850-125
Cast - Painted Black 850-126
Cast - Gold Plated
850-127
10) NOTE: Residential Close Clearance
and Alcove installations require a list-
ed double wall connector from the
stove collar to the ceiling level.
The instructions below apply to the steel leg,
painted cast leg and the gold plated cast leg. It
will be easier to attach the legs to the stove if
it is tipped on its back (preferably on a soft
surface to prevent scratching).
1) With your location already established, cut
and frame the roof hole. It is recommended
that no ceiling support member be cut for
chimney and support box installation. If it is
necessary to cut them, the members must
be made structurally sound.
The diagrams below illustrate one way to install
your unit into a standard ceiling or with a
horizontal connector. Check with your dealer
or installer for information on other options
available to you.
1) Remove the 4 bolts in the underside of the
base and discard.
2) Line up the bottom of the heat shield (with
cover plate facing front) with the bottom of
the unit.
2) Installradiantshieldandsupportfromabove.
3) Stack the insulated pipe onto your finish
support to a minimum height of 3 feet above
the roof penetration, or 2 feet above any
point within 10 feet measured horizontally.
There must be at least 3 feet of chimney
above the roof level.
3) Start threading the bolt and washer (sup-
plied with the bottom shield) for about 1/4
of the way through the leg.
4) Place the spacers into position in the 4
corners of the bottom shield on top of the
bolts.
Note: Increasing the chimney height
above this minimum level will
sometimes help your unit to
“breathe” better by allowing a
greater draft to be created. This
greater draft can decrease prob-
lems such as, difficult start-ups,
back-smoking when door is open,
and dirty glass. It might be suffi-
cient to initially try with the mini-
mum required height, and then if
problems do arise add additional
height at a later date.
Standard Ceiling Installation
4) Slide the roof flashing over your chimney
and seal the flashing to the roof with
roofing compound. Secure the flashing to
your roof with nails or screws.
5) Install all 4 legs with the washer underneath
the leg and tighten the bolts.
6) Level the stove by adjusting the levelling
bolts in the bottom of each leg.
5) Place the storm collar over the flashing,
sealing the joints with a silicone caulking.
6) Fasten the raincap with spark screens (if
required) to the top of your chimney.
7) For optimum efficiency when installing into
a masonry chimney, size accordingly, i.e.
the 6" flue dia. is 28.28 sq.in.
Horizontal Installation
13
Regency Freestanding Woodstove
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
TABLE 1
MINIMUMRECOMMENDEDFLUEHEIGHTSINFEET
(Measured from the top of the unit)
# OF ELBOWS
ELEVATION (FT)
ABOVE SEA LEVEL
0
2 x 15o 4 x 15o 2 x 30o 4 x 30o 2 x 45o 4 x 45o
0-1000
1000-2000
2000-3000
3000-4000
4000-5000
5000-6000
6000-7000
7000-8000
8000-9000
9000-10000
12.0
12.5
13.0
13.5
14.0
14.5
15.0
15.5
16.0
16.5
13.0
13.5
14.0
14.5
15.0
15.5
16.0
16.5
17.0
17.5
14.0
14.5
15.0
15.5
16.0
17.0
17.5
18.0
18.5
19.0
15.0
15.5
16.0
17.0
17.5
18.0
18.5
19.0
20.0
20.5
18.0
19.0
19.5
20.0
21.0
21.5
22.5
23.0
24.0
24.5
16.0
16.5
17.0
18.0
18.5
19.0
20.0
20.5
21.0
22.0
20.0
21.0
21.5
22.5
23.0
24.0
25.0
25.5
26.5
27.0
NOTE: No more than two offsets (four elbows) allowed. Two 45o elbows equal one 90o elbow.
RECOMMENDED
HEIGHTS FOR
WOODSTOVE FLUE
MOBILE HOME INSTALLATION
Once you have properly marked the position of
your unit and the floor protection as outlined in
the Residential Installation items #1 through #8,
a supply of fresh air has to be supplied to your
unit.Cutaminimum4inchdiameterholethrough
your floor protector and the floor directly under
your pedestal base to the outside. Use 4" duct
pipe with a mesh grill to pipe fresh air into the
pedestal area. Block off the hole in the back of
the pedestal with the square plate and the two
1/2" screws provided.
Simple rules on draft. See Table 1.
1) At sea level minimum height is 12' straight.
2) Add the following vertical height to com-
pensate for:
45 deg. elbow = 1 ft.
90 deg. elbow = 2 ft.
"T"
= 3 ft.
Place your unit in position and secure it to the
floor using two lag bolts 3/8" x 3-1/2" through
the two holes inside the pedestal base. It is
important to maintain the structural integrity of
the Mobile Home floor, walls and roof when
installing your unit.
Each foot of horizontal run = 2 ft.
3) Add 4% overall for each 1000' above sea
level.
Example: a)
1-1/2 ft. of horizontal run
one "T"
Total Addition (at sea level) = 6 ft.
= 3 ft.
= 3 ft.
For Mobile Home units installed in the U.S. the
unit must be grounded using a #8 ground wire
with approved termination and star washer.
Example: b)
One 90 deg. elbow
= 2 ft.
= 4 ft.
= 3 ft.
2 ft. of horizontal run
one "T"
Total Addition (at sea level) = 9 ft.
Recommended Flue Height
Elevation
0'
Example a)
18'
Example b)
21'
1000'
2000'
5000'
8000'
18.72'
19.44'
21.60'
23.76'
21.84'
22.68'
25.20'
27.72'
Regency Freestanding Woodstove
14
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
SIMPSONDURA-PLUS
Qty.Part # Description
6DVL8693 Connector Kit
6DP-MH9096 MobileHomeKit
Large Stoves F3100L and S3100L
LISTED COMPONENTS
FOR MOBILE HOME
INSTALLATION
1
1
The unit arrives with the first two air tubes (from
the front) and the 2 baffle bricks on the floor of
the firebox. The baffle bricks are positioned
first and then the air tubes are installed.
ICC EXCEL 2100
Qty.Part # Description
TheRegencySmall,Medium,MediumStep and
Large Freestanding pedestal units are ap-
provedforinstallationinaMobileHomeifoneof
the following pipe systems is used.
1
6CL48
48"Chimneylength(alsoin12",
18", 24" lengths.
NOTE: If the first 2 airtubes are already
installed in the stove, they must
be removed in order to install the
Brick Baffles.
1
1
1
1
1
6RC
6RCS
RainCap
Spark Screen (for rain cap)
6RDS/SQS Round/Square support box
6VF
6UBA
U.S. Installation*
Flashing
"Ultrablack" Close Clearance
Connector
1) Slide the left baffle brick over the two rear
air tubes and then push it all the way to the
left side of the firebox.
METALBESTOS SSII
Qty. Part #
Description
1
1
1
1
1
1
6DS-VK
6TMH
6TAF-6
6T-36
6T-18
6T-CT
Connector Kit
Shield/Support
Flashing
Chimney Length
Chimney Length
RainCap
Canadian Installations*
SECURITY S2100 (see above for details)
ICC EXCEL 2100 (see above for details)
*The use of alternate pitch flashings, support
box extensions, additional chimney lengths, and
additional chimney bracing, may be used on
each of the previously listed systems. These
parts though must be from the same system as
listed, and must be a similar and/or complimen-
tary part.
PRO-JET 3103
Qty.Part #
Side View
Description
Connector
1
1
1
1
1
1
1
PV06-TK
CSB
RRS
LFR03
SL3
SL1
Shield/Support
RadiationShield
Flashing
Chimney Length
Chimney Length
RainCap
CAUTION:Atnotimeuseunlabelled
parts, or substitute parts made for
another chimney system.
RCSA
SECURITYASHT
Qty.Part # Description
1
1
1
1
1
1
DL42A-6
Connector Kit
Shield/Support
Flashing
Chimney Length
Chimney Length
RainCap
Install as per chimney manufacturer's installa-
tion instructions.
6SS
6FAMH
6L3
6L1
CPE
2) Tilt the first Baffle Brick down and then slide
the 2nd Baffle Brick up and back. Reposi-
tion both baffle bricks flat on the air tubes.
BRICK FLUE BAFFLE &
SECONDARY AIR TUBE
INSTALLATION
SECURITYS2100
Qty.Part # Description
1
1
1
1
1
1
DL42A-6
Connector Kit
Support
Flashing
Chimney Length
Chimney Length
RainCap
6XSF
6XFA
6XL3
6XL18
6XCPE
The flue baffle system located in the upper area
of the firebox is removable to make cleaning
your chimney system easier. The brick baffles
must be installed prior to your first fire. Smoke
spillage and draft problems may occur if
the baffles are improperly positioned.
Check the position of the brick baffles on a
regular basis as they can be dislodged if too
much fuel is forced into the firebox.
METAL-FAB TEMP/GUARD 2100
Qty.Part #
Description
Connector
Roof Support
Chimney Length
Chimney Length
Flashing
1
1
1
1
1
1
6DWBK
6TGRS
6TGG36
6TGG12
6TGF
3) Important: push both baffle bricks so
they are tight against the side walls.
The Large Stoves F3100L and S3100L are
shipped with two of the secondary air tubes
loose inside the firebox. They need to be in-
stalled after the brick baffle are installed. Follow
the directions below.
6TGC
RainCap
AMERI-TEC HS
Qty.Part #
Description
Connector
1
1
1
1
1
1
6DCC
6HSRS-12 Roof Support (6PLRS-12-BK)
6F
6HS-36
6HS-18
Flashing
Chimney Length
Chimney Length
Front View
6HS-RCS RainCap(6PL-MPC)
15
Regency Freestanding Woodstove
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
4) Install the two front air tubes into the holes
on the side channels. The notch goes on
the right hand side with the air holes facing
forward toward the door opening. If the
tubewillnotslideineasily, simplyuseapair
of vise grips or pliers and tap it into place
with a hammer. A tighter fit will ensure the
tube will not move when the unit is burning.
manner as Step 1) above. Then reposition
the left baffle brick flat on the air tubes.
Side View
3) Tilt the left baffle brick up on top of the side
channel and it will leave enough room to
position the right baffle brick in the same
manner as Step 1) above. Then reposition
the left baffle brick flat on the air tube.
Front View
4) Important: push both baffle bricks so
they are tight against the side walls.
Note: When cleaning the chimney re-
verse the above procedures, re-
moving the air tube and baffle
bricks and then replace them when
cleaning is completed.
Front View
Front View
4) Important: push both baffle bricks so
they are tight against the side walls.
Note: When getting the chimney cleaned,
push the brick baffles forward
toward the front of the stove, this
should leave sufficient access to
the flue. If it is not enough space
then remove the middle air tube
(reverse the procedure in step 1)
above), and baffle bricks and then
replace everything when cleaning
is completed.
Medium Stoves
F2100M and S2100M
The unit arrives with the 2 baffle bricks on the
floor of the firebox.
1) If all 3 air tubes are installed continue on to
Step 2), if not, follow the instructions be-
low. Install the air tube into the holes in the
side channels. The notch goes on the right
hand side with the air holes facing toward
the door. Slide the tube into the left hand
side, as far as possible and then bring it
backintotheholeontherighthandsideuntil
it locks into position. If the tube will not slide
in easily, simply use a pair of vise grips or
pliers and tap it into place with a hammer. A
tighter fit will ensure the tube will not move
when the unit is burning. See the diagram
for the large air tube installation (page 15),
though there are only three air tubes in the
mediumunits.
Front View
Small Stoves F1100S
Note: When getting the chimney cleaned,
remove the baffle bricks for ac-
cess to the flue, then replace them
when cleaning is completed.
1) If the two air tubes are installed continue on
to Step 2), if not, follow the instructions
below.Installtheairtubeintotheholesinthe
side channels. The notch goes on the right
hand side with the air holes facing toward
the door. Slide the tube into the left hand
side, as far as possible and then bring it
backintotheholeontherighthandsideuntil
it locks into position. If the tube will not slide
in easily simply use a pair of vise grips or
pliers and tap it into place with a hammer. A
tighter fit will ensure the tube will not move
when the unit is burning. See the diagram
for the large air tube installation (page 15),
though there are only two air tubes in the
small units.
2) Slide the left baffle brick over the air tubes
from the front and then push it to the back.
2) Slide the left baffle brick over the front air
tube and then slide it back over the rear air
tube.
Side View
3) Tilt the left baffle brick up on top of the side
channel and it will leave enough room to
position the right baffle brick in the same
Regency Freestanding Woodstove
16
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Pedestal Ash Drawer Kit (850-100)
BRICK INSTALLATION
DOOR HANDLE
1) Remove the bricks from the floor of the
Firebrick is included to extend the life of your Attach spring handle by rotating counter clock-
stove and radiate heat more evenly. Check to wise onto rod. Ensure that the rod fits into the
see that all firebricks are in their correct posi- entire length of the spring handle. See Diagram
tions and have not become misaligned during below.
firebox.
2) If using ashdrawer, discard cover plate.
shipping.
3) Remove the ash dump cover plates (one
inside the firebox and one on the underside
of the firebox) by removing the two nuts
and bolts holding the 2 plates together from
inside the firebox.
The"AD"brickinthedrawingsaboveisthebrick
covering the Ash Dump hole that is used when
the Ash Drawer Kit is installed. See page 17 for
more information.
4) Push the ash plug into the hole inside the
firebox and replace all the bricks except for
the brick over the ash plug. See the brick
diagrams on page 17.
5) Place the ash drawer lid inside the pedes-
tal, and the ash plug tool beside the lid, then
slide the ash drawer inside so it sits on top
of the lid.
GLASS INSTALLATION
Your Regency stove is supplied with 5 mm
Neoceram ceramic glass that will withstand the
highest heat that your unit will produce. In the
Freestanding - Small F1100
event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only.
Remove the door from the stove and remove
the glass retainer. Position the glass in the door,
make sure that the glass gasketing will properly
seal your unit, and replace the retainer, it should
restonthegasketnottheglass. Tightensecure-
ly, but do not wrench down on the glass as this
may cause the glass to break.
See page 20 for Ash Drawer Operating in-
structions.
Bottom Shield Ash Drawer Kit
(850-101)
1) Remove the bricks from the floor of the
firebox.
2) Remove and discard the cover plate by
removing the two screws on the front of
the Bottom Shield.
Freestanding - Medium
F2100 & S2100
3) Remove the ash dump cover plates (one
inside the firebox and one on the underside
of the firebox) by removing the two nuts
andboltsholdingthe2platestogetherfrom
inside the firebox.
4) Push the ash plug into the hole inside the
firebox and replace all the bricks except for
the brick over the ash plug. See the brick
diagrams on page 16.
OPTIONAL
ACCESSORIES
5) Place the ash plug tool beside the lid, then
slide the ash drawer inside.
The pieces listed below can be purchased and
installedduringtheinitialinstallationoraddedon
later.
Freestanding - Large F3100
See page 20 for Ash Drawer Operating in-
structions.
17
Regency Freestanding Woodstove
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Blower/Fan(846-515)
1) Remove the two screws from the top of the
fan housing.
2) Slide the fan up into the rear heat shield.
3) After aligning holes, secure the fan to the
rear heat shield using the two screws
removed earlier.
Note: The connection cord should not
be in contact with any hot surfac-
es.
Read the operating instructions for the fan
before using. See Page 19.
Blower/Fan Wiring Diagram
WARNING:ElectricalGroundingInstructions
Thisapplianceisequippedwithathreepronged(ground-
ing) plug for your protection against shock hazard and
should be plugged directly into a properly grounded
three-prongreceptacle.Donotcutorremovetheground-
ing prong from this plug.
CAUTION: Labelallwirespriortodisconnection
whenservicingcontrols.Wiringerrorscancause
improper and dangerous operation.
Regency Freestanding Woodstove
18
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
4) After about 15 to 20 minutes, when your
CAUTION: If the body of your unit,
flue baffle or any part of the chim-
ney connector starts to glow, you
are overfiring. Stop loading fuel
immediately and close the draft
control until the glow has com-
pletely subsided.
OPERATING
INSTRUCTIONS
wood has begun to burn strongly, adjust
your draft control down to keep the fire at
a moderate level.
With your unit now correctly installed and
safety inspected by your local authority, you
are now ready to start a fire. Before establish-
ing your first fire, it is important that you fully
understand the operation of your draft control.
WARNING: Never build a roaring fire in
a cold stove. Always warm your
stove up slowly!
5) Once a bed of coals has been established,
you may adjust the draft control to a low
setting to operate the unit at its most effi-
cient mode.
14) Green or wet wood is not recommended
for your unit. If you must add wet or green
fuel, open the draft control fully until all
moisture has been dispersed by the in-
tense fire. Once all moisture has been
removed, the draft control may be adjusted
to maintain the fire.
DRAFT CONTROL
Both the primary and air wash drafts are
controlled by the control rod located on the left
side of the unit (when facing the unit). To
increase your draft - pull open, and to decrease
- push closed. All units have a secondary draft
system that continually allows combustion air
to the induction ports at the top of the firebox,
just below the flue baffle.
6) During the first few fires, keep the com-
bustion rate at a moderate level and avoid
a large fire. Only after 5 or 6 such fires can
you operate the stove at its maximum
setting, and only after the metal has been
warmed.
15) If you have been burning your stove on a
low draft, use caution when opening the
door. After opening the damper, open the
door a crack, and allow the fire to adjust
before fully opening the door.
7) For the first few days, the stove will give
off an odour from the paint. This is to be
expected as the high temperature paint
becomes seasoned. Windows and/or
doors should be left open to provide ade-
quate ventilation while this temporary con-
dition exists. Burning the stove at a very
high temperature the first few times may
damage the paint. Burn fires at a moderate
level the first few days.
Important: If you are using room air for
combustion, make sure that the back cover
plate at the rear of the pedestal is not installed.
The cover plate must be installed on the unit if
yourstoveislocatedinamobilehomeorifusing
outside air.
16) The controls of your unit or the air supply
passages should not be altered to increase
firing for any reason.
17) If you burn the unit too slowly or at too low
a setting your unit will not be operating as
efficiently as it can. An easy rule of thumb
says that if your glass is clean, then your
flue is clean and your exhaust is clean.
Burn the stove hot enough to keep your
glass clean and you won't need to clean
your flue as often.
8) Do not place anything on the stove top
during the curing process. This may result
in damage to your paint finish.
Pull - Open
Push - Closed
WARNING: To build a fire in ignorance or
to disregard the information contained in
this section can cause serious perma-
nent damage to the unit and void your
warranty!!
9) During the first few days it may be more
difficult to start the fire. As you dry out your
firebrick and your masonry flue, your draft
will increase.
FAN OPERATION
Automatic
10) For those units installed at higher eleva-
tions or into sub-standard masonry fire-
places, drafting problems may occur. Con-
sult an experienced dealer or mason on
methods of increasing your draft.
To operate the fan automatically, push the
bottom switch on the side of the fan housing to
"AUTO" and the top switch to either "HIGH" or
"LOW" for fan speed.
FIRST FIRE
When your installation is completed and in-
spected you are ready for your first fire.
This will allow the fan to turn on as the stove
has come up to operating temperature. It will
also shut the fan system off after the fire has
gone out and the unit cooled to below a useful
heat output range.
11) Somecrackingandpoppingnoisesmaybe
experienced during the heating up proc-
ess. These noises will be minimal when
your unit reaches temperature.
1) Open control fully.
2) Open firebox door and build a small fire
using paper and dry kindling. Secure door
on the firebox and wait a few minutes for
a good updraft in the flue to establish the
fire. (Leaving the door slightly open will help
your fire start more rapidly.)
12) Before opening your door to reload, open
draft fully for approximately 10 to 15 sec-
onds until fire has been re-established.
This will minimize any smoking.
Manual
To manually operate the fan system push the
bottom switch to "MAN" and the top switch to
either "HIGH" or "LOW". This will bypass the
sensing device and allow full control of the fan.
13) All fuel burning appliances consume oxy-
gen during operation. It is important that
you supply a source of fresh air to your unit
while burning. A slightly opened window
is sufficient for the purpose. If you also
have a fireplace in your home, a downdraft
may be created by your Regency Stove
causing a draft down your chimney. If this
occurs, slightly open a window near your
unit.
CAUTION: Never leave unit unattend-
ed if door is left open. This procedure
is for fire start-up only, as unit may
overheat if door is left open for too
long.
Switching from "AUTO" to "MAN" or "HIGH" to
"LOW" may be done anytime.
3) With the draft still in the fully open position
add two or three seasoned logs to your fire.
Form a trench in the ash bed to allow air to
reach the rear of the firebox prior to closing
the door.
19
Regency Freestanding Woodstove
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
Bottom Shield (with Legs) Units:
To remove the drawer, lift slightly and slide
it out, and carry it away.
clothing and furniture away. Warn chil-
dren of the burn hazard.
ASH DISPOSAL
During constant use, ashes should be removed
every few days. The Ash Drawer option fea-
tures a convenient ash dump for easy removal
of ash, see "Modular Options" on page 9.
8) The stove consumes air while operating,
provide adequate ventilation with an air
duct or open a window while the stove is
in use.
Safety Precautions
9) Do not connect this unit to a chimney flue
serving another appliance.
4) When emptying the ash drawer, make sure
the ashes are cold. Ashes should be placed
inametalcontainerwithatightfittinglid. The
closed container of ashes should be placed
onanon-combustiblefloororontheground,
well away from all combustible materials,
pending final disposal. If the ashes are
disposed of by burial in soil or otherwise
locally dispersed, they should be retained
in the closed container until all cinders have
thoroughly cooled. Other waste should not
be placed in the ash container.
1) Do not allow ashes to build up to the loading
doors! Only remove ashes when the fire
has died down. Even then, expect to find
a few hot embers.
10) Do not use grates or andirons or other
methods for supporting fuel. Burn directly
on the bricks.
2) Please take care to prevent the build-up of
ash around the start-up air housing located
inside the stove box, under the loading door
lip.
11) Open the draft control fully for 10 to 15
seconds prior to slowly opening the door
when refuelling the fire.
12) Do not connect your unit to any air distribu-
3) Never start a fire if the ash plug and ash
drawer are not in place. This will cause
overfiring which can cause excessive
warping of the stove. Evidence of overfir-
ing can void the warranty on your stove.
tion duct.
13) Your woodstove should burn dry, stand-
ard firewood only. The use of cut lumber,
plywood, “mill ends”, etc. is discouraged
as this fuel can easily overheat your
woodstove. Evidence of excessive over-
heating will void your warranty. As well,
a large portion of sawmill waste is chem-
icallytreatedlumber, whichisillegaltoburn
in many areas. Salt drift wood and chem-
ically treated fire logs also must not be
burned in your woodstoves.
5) Before putting the ash drawer back into
place, make sure the ash plug is back in
place.
4) The firebricks are brittle and can be dam-
aged if the plug is replaced carelessly or
pieces that are too large are forced through
the hole.
Pedestal Units: make sure the cover lid is
off.
SAFETY GUIDELINES
AND WARNINGS
Ash Drawer Operating Guideline
1) Only clean ashes out of the stove when the
unit has cooled down. Remove the plug by
lifting on the handle using the tool provided.
The plug may still be warm, use caution.
Push the ashes down the hole into the ash
drawer, the large pieces can be left in the
firebox and burned during the next fire or
removed through the door opening.
14) Do not store any fuel closer than 2 feet from
your unit. Do not place wood, paper, fur-
niture, drapes or other combustibles near
the appliance.
1) Never use gasoline, gasoline type lantern
fuels, kerosene, charcoal lighter fuel, or
similar liquids to start or ‘freshen up’ a fire
in your heater. Keep all such liquids well
away from the heater while it is in use.
15) WARNING: Do not operate without
either the Ash Plug properly seated
or the Ash Dump Plates screwed in
place, excessive temperatures will
result.
2) Keep the door closed during operation and
maintain all seals in good condition.
3) Do not burn any quantities of paper, gar-
bage, andneverburnflammablefluidssuch
as gasoline, naptha or engine oil in your
stove.
16) Do not operate with broken glazing.
4) Ifyouhavesmokedetectors,preventsmoke
MAINTENANCE
spillage as this may set off a false alarm.
2) Always leave 1/2 to 1 inch of ash in the
bottom of the firebox. This helps in easier
starting and a more uniform burn of your
fire. Replace ash plug when ashes have
been removed.
It is very important to carefully maintain your
fireplace stove, including burning seasoned
wood and maintaining a clean stove and chim-
ney system. Have the chimney cleaned before
the burning season and as necessary during
the season, as creosote deposits may build up
rapidly. Moving parts of your stove require no
lubrication.
5) Do not overfire heater. If the chimney con-
nector, flue baffle or the stove top begin to
glow, you are overfiring. Stop adding fuel
and close the draft control. Overfiring can
cause extensive damage to your stove
including warpage and premature steel
corrosion. Overfiring will void your war-
ranty.
3) Pedestal Units:
To remove the drawer, lift slightly and slide
it out. When the drawer is completely out,
slide the cover plate over the ash drawer
and carry away.
6) Do not permit creosote or soot build-up in
thechimneysystem.Checkandcleanchim-
ney at regular intervals. Failure to do so can
result in a serious chimney fire.
7) Your Regency stove can be very hot. You
may be seriously burned if you touch the
stove while it is operating, keep children,
Regency Freestanding Woodstove
20
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
GLASS MAINTENANCE
CREOSOTE
LATCH ADJUSTMENT
Your Regency stove is supplied with 5 mm
Neoceram ceramic glass that will withstand
the highest heat that your unit will produce. In
the event that you break your glass by impact,
purchase your replacement from an author-
ized Regency dealer only, and follow our step-
by-step instructions for replacement.
When wood is burned slowly, it produces tar
and other organic vapours, which when com-
bined with moisture, form creosote. The creo-
sote vapours condense in the relatively cool
chimney flue of a slow burning fire. As a result,
creosote residue accumulates on the flue lin-
ing. When ignited, this creosote can result in an
extremely hot fire.
The door latch may require adjustment as the
door gasket material compresses after a few
fires. Removal of the spacer washer, shown
in the diagram below, will allow the latch to be
moved closer to the door frame, causing a
tighter seal. Remove and replace the nuts,
washer and spacer as shown.
Allow the stove to cool down before cleaning
the glass, do not clean the glass when it is hot.
Do not use abrasive cleaners.
WARNING: Things to remember in case of a
chimney fire:
1. Close all draft and damper controls.
Glass Replacement
2. CALL THE FIRE DEPARTMENT.
Allow the stove to cool before removing or
replacing glass. Remove the door from the
stove and remove the glass retainer. Use
caution when removing broken glass to avoid
injury. When placing the replacement glass in
the door, make sure that the glass gasketing
will properly seal your unit. Replace the retain-
er,itshouldrestonthegasketnottheglass,and
tighten securely, but do not wrench down on
the glass as this may cause breakage.
Ways to Prevent and Keep Unit
Free of Creosote
DOOR GASKET
If the door gasket requires replacement 7/8" diam-
eter material must be used. Regency uses AMA-
TEX # 10-863KR 7/8" dia. gasket. A proper high
temperaturegasketadhesiveisrequired. Seeyour
Regency Dealer.
1) Burn stove with the draft control wide open
for about 10-15 minutes every morning
during burning season.
2) Burn stove with draft control wide open for
about 10 - 15 minutes every time you apply
fresh wood. This allows the wood to
achievethecharcoalstagefasterandburns
up any unburned gas vapours which might
otherwise be deposited within the system.
Do not use substitute materials. If your glass
does break, do not continue to use your unit
until it has been replaced.
3) Only burn seasoned wood! Avoid burn-
ing wet or green wood. Seasoned wood
has been dried at least one year.
4) A small hot fire is preferable to a large
smouldering one that can deposit creosote
within the system.
5) Check the chimney at least twice a month
during the burning season for creosote
build-up.
6) Have chimney system and unit cleaned by
competent chimney sweeps twice a year
during the first year of use and at least once
a year thereafter or when a significant
layer of creosote has accumulated (3 mm/
1/8"ormore)itshouldberemovedtoreduce
the risk of a chimney fire.
MAINTENANCE OF
GOLD-PLATED DOORS
The gold electroplated finish on the door re-
quires little maintenance, and need only be
cleaned with a damp cloth. DO NOT use abra-
sive materials or chemical cleaners, as they
may harm the finish and void the warranty.
21
Regency Freestanding Woodstove
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS LIST
F1100 & F3100 STOVE MAIN ASSEMBLY
Part #
Description
Part #
Description
1)
3)
846-913
846-915
846-910
846-916
Door Assy-Sm/Med Gold F1100 (no glass)
Door Assy-Sm/Med Black F1100 (no glass)
Door Assy-Large Gold F3100 (no glass)
Door Assy-Large Black F3100 (no glass)
25) 910-684
Power Cord (120 V)
27) 910-142
28) 910-138
29) 910-140
30) 910-157/P
35) 063-954
074-954
36) 033-953
063-953
37) 073-955
063-955
Thermodisc Fan AutoON/OFF
Manual/Auto Switch (2-way)
Fan Speed Switch HI/OFF/LOW (3-way)
Fan/Blower Motor (120 V)
Air Tube - 1" F3100 (Qty:1)
Air Tube - 1" F1100 (Qty: 1)
Air Tube - 3/4" F1100 (Qty: 1)
Air Tube - 3/4" F3100 (Qty: 3)
Baffle (set) F1100
846-302
846-304
936-243
846-920
*
948-170/P
948-172/P
846-973
Glass - Replacement - Small/Medium F1100
Glass - Replacement - Large F3100
7/8" Adhesive Tape Gasket
Glass Retainer Clips (8/set)
Screw - 1/4 - 20 x 3/8"
Small Glass Retainer F1100
Large Glass Retainer F3100
Door Handle Assembly
4)
5)
6)
7)
Baffle (set) F3100
40) 815-557
815-558
41) 850-105
850-305
Rear Air Deflector- F1100
Rear Air Deflector - F3100
Airmate - Sm/Med. F1100
Airmate - Large F3100
9)
12) 820-375
13)
14) 820-376
15)
Ash Hole Cover Plate
*
Bolt 1/4 - 20 x 1/2 Hex Head
Retainer Plate - Ash Dump - Top
Nut - 1/4 - 20 Hex
*
908-288
Manual
16) 846-570
17) 846-918
19) 948-101
20) 948-102
846-515
7/8" Door Gasket Repair Kit
Hinge Cap - Gold (2/set)
Spring Handle - Large
Spring Handle - Small
Complete Fan/Blower Assy (120 V)
*Not available as a replacement part.
Regency Freestanding Woodstove
22
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS LIST
F2100 STOVE MAIN ASSEMBLY
Part #
Description
Part #
Description
1)
846-913
846-915
Door Assy-Med Gold F2100 (no glass)
Door Assy-Med Black F2100 (no glass)
846-515
25) 910-684
Complete Fan/Blower Assy (120 V)
Power Cord (120 V)
27) 910-142
28) 910-138
29) 910-140
30) 910-157/P
36) 033-953
37) 033-957
40) 815-557
41) 850-105
Thermodisc - Fan AutoON/OFF
Manual/Auto Switch (2-way)
Fan Speed Switch HI/OFF/LOW (3-way)
Fan/Blower Motor (120 V)
Air Tube - 3/4" F2100 (Qty: 3)
Baffle (set) F2100
3)
4)
5)
6)
7)
9)
846-302
936-243
846-920
*
948-170/P
846-973
Glass - Replacement - Medium F2100
7/8" Adhesive Tape Gasket
Glass Retainer Clips (8/set)
Screw - 1/4 - 20 x 3/8"
Small Glass Retainer F2100
Door Handle Assembly
Rear Air Deflector- F2100
Airmate - Medium .F2100
12) 820-375
13)
14) 820-376
15)
Ash Hole Cover Plate
*
Bolt 1/4 - 20 x 1/2 Hex Head
Retainer Plate - Ash Dump - Top
Nut - 1/4 - 20 Hex
908-288
Manual
*
16) 846-570
17) 846-918
19) 948-101
20) 948-102
7/8" Door Gasket Repair Kit
Hinge Cap - Gold (2/set)
Spring Handle - Large
*Not available as a replacement part.
Spring Handle - Small
23
Regency Freestanding Woodstove
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS LIST
S2100 & S3100 STEP STOVE MAIN ASSEMBLY
Part #
Description
Part #
Description
17) 846-918
Hinge Cap - Gold (2/set)
Spring Handle - Large
Spring Handle - Small
Complete Fan/Blower Assy (120 V)
Power Cord (120 V)
Thermodisc Fan Auto ON/OFF
Manual/Auto Switch (2-way)
Fan Speed Switch HI/OFF/LOW (3-way)
Fan/Blower Motor (120 V)
Air Tube - S3100 (Qty:1)
Air Tube - 3/4" S2100 (Qty: 3)
Air Tube - 1" S3100 (Qty: 3)
Baffle (set) S2100
1)
3)
846-913
846-915
846-910
846-916
846-302
846-304
936-243
846-920
*
948-170/P
948-172/P
130-006
130-005
150-006
150-005
846-973
Door Assy- Medium Gold S2100 (no glass)
Door Assy-Medium Black S2100 (no glass)
Door Assy-Large Gold S3100 (no glass)
Door Assy-Large Black S3100 (no glass)
Glass - Replacement - Medium - S2100
Glass - Replacement - Large - S3100
7/8" Adhesive Tape Gasket
Glass Retainer Clips (8/set)
Screw - 1/4 - 20 x 3/8"
Small Glass Retainer - S2100
Large Glass Retainer - S3100
Side Panel - Right - S2100
19) 948-101
20) 948-102
846-515
25) 910-684
27) 910-142
28) 910-138
29) 910-140
30) 910-157/P
35) 063-954
36) 033-953
063-953
4)
5)
6)
7)
8)
37) 033-955
063-955
Side Panel - Left - S2100
Side Panel - Right - S3100
Side Panel - Left - S3100
Door Handle Assembly
Baffle (set) S3100
908-288
Manual
9)
16) 846-570
7/8" Door Gasket Repair Kit
*Not available as a replacement part.
Regency Freestanding Woodstove
24
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS LIST
PEDESTAL, BOTTOM SHIELD & LEG OPTIONS
Part #
Description
48) 850-115
850-215
Pedestal - Small
Pedestal - Medium
Pedestal - Large
850-315
49) 904-257
Large Magnet Catch
Blanking Plate - Pedestal
50)
*
850-100
*
*
Ashdrawer Kit - Pedestal
Ashdrawer - Pedestal
Ashdrawer Lid Assy
Ash Plug
45)
46)
58) 942-110
59) 820-249
Ash Plug Tool Handle
56) 850-121
850-221
Bottom Shield - Small
Bottom Shield - Medium
Bottom Shield - Large
Blanking Plate - Btm Shield
850-321
57)
*
850-101
*
58) 942-110
59) 820-249
Ashdrawer Kit - Btm Shield
Ashdrawer - Bottom Shield
Ash Plug
55)
Ash Plug Tool Handle
140) 850-126
850-127
142) 850-125
948-216
Legs - Cast Black
Legs - Cast Gold
Legs - Steel Black
Logo - Regency
*Not available as a replacement part.
25
Regency Freestanding Woodstove
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS LIST
FIREBRICK
Part #
Description
70) 902-111
71) 802-104
72) 802-122
73) 802-146
74) 802-147
Brick - Regular Full Size: 1-1/4" x 4-1/2" x 9"
Brick Partial: 1-1/4" x 4" x 9"
Brick Partial: 1-1/4" x 2" x 4-1/2"
Brick Partial: 1-1/4" x 1-3/4" x 9"
Brick Partial: 1-1/4" x 4-1/2" x 3-1/2"
76) 802-152
77) 802-145
78) 802-149
79) 802-153
80) 802-154
Brick Partial: 1-1/4" x 2" x 9"
Brick Partial: 1-1/4" x 3-1/4" x 9"
Brick Partial: 1-1/4" x 4-1/2" x 3-1/4"
Brick Partial: 1-1/4" x 4-1/2" x 2-1/4"
Brick Partial: 1-1/4" x 6-1/2" x 2-1/4"
81) 802-135
82) 802-155
83) 802-138
84) 802-107
85) 802-156
Brick Partial: 1-1/4" x 1-1/4" x 9"
Brick Partial: 1-1/4" x 3-1/8" x 4-1/2"
Brick Partial: 1-1/4" x 3-3/8" x 9"
Brick Partial: 1-1/4" x 4-1/2" x 8"
Brick Partial: 1-1/4" x 4-1/4" x 8"
Regency Freestanding Woodstove
26
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY
Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance
Teamcarefullyinspectseachunitthoroughlybeforeitleavesourdoor. RegencyIndustriesLtd.ispleasedtoextendthislimited
lifetime warranty to the original purchaser of a Regency Product.
The Warranty: Lifetime
Covered under the agreement are the following components:
Firebox, ceramic baffle, convector airmate, castings, ashdrawer, glass (thermal breakage) and all gold plating (against defective
manufacture).
The above will be covered for parts and labour for the first five years and parts only thereafter.
Electrical components such as blowers and switches are covered for one year from the date of purchase.
Conditions:
Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option,
through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation
Prepaid, if requested.
Exclusions:
This limited Lifetime Warranty does not extend to include paint, door or glass gasketing, firebrick or trim. It does not cover installation
and operational related problems such as over-firing, use of corrosive driftwood, downdrafts or spillage caused by environmental
conditions, nearby trees, buildings, hilltops, mountains, inadequate venting or ventilation, excessive offsets, negative air pressures
caused by mechanical systems such as furnaces, fans, clothes dryers etc.
It is essential that all submitted claims provide all of the necessary information including purchase date, serial #, type of unit and
part or parts requested.
27
Regency Freestanding Woodstove
Download from Www.Somanuals.com. All Manuals Search And Download.
Regency fireplace products are designed
with reliability and simplicity in mind. In
addition, our internal Quality Assurance
Teamcarefullyinspectseachunitthor-
oughly before it leaves our door.
Fireplace Products International
Ltd.ispleasedtoextendthisLimited
Lifetime Warranty to the original pur-
chaser of a Regency Product.
See the inside back cover for details.
Register your Regency online at
Installer:Pleasecompletethefollowinginformation
Dealer Name & Address:______________________________________________
__________________________________________________________________
Installer: ___________________________________________________________
Phone #: ___________________________________________________________
Date Installed: ______________________________________________________
Serial No.: _________________________________________________________
Regency and Classic are trademarks of FPI Fireplace Products International Ltd.
© FPI Fireplace Products International Ltd. 2003
Printed in Canada
Download from Www.Somanuals.com. All Manuals Search And Download.
|