Redring Plumbing Product 320S User Guide

REDRING ACTIVE 320S  
SMART TECHNOLOGY  
ELECTRIC SHOWER  
Installation and User Guide  
IMPORTANT:  
This booklet should be left with the user after  
installation and demonstration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Isolate the mains electrical and water supply before removing the front cover of the appliance.  
HOW TO USE YOUR ACTIVE 320S SHOWER (DETAILED)  
1. Ensure the electricity and water are turned on to the unit.  
2. Your shower has 3 power settings selected by turning outer  
knob “A”.  
The most popular is “  
There are also options for a “  
or “ (cold)” shower (see notes 8 and 9).  
(high)”.  
(medium)”  
For this example turn outer knob “A” to “  
and set inner knob “B” to “12 o’clock”.  
(high) ”  
3. The water will flow and the neon light will glow brightly.  
4. Allow about 20 seconds for the temperature of the water  
to stabilise.  
IF WATER IS TOO COLD  
IF WATER IS TOO HOT  
Turn inner knob “B” clockwise in the  
direction of the “red arrows” to “1 o’clock”  
and continue turning clockwise until you get  
the water temperature of your liking.  
Turn inner knob “B” anti-clockwise in the  
direction of the “blue arrows” to “11 o’clock”  
and continue turning anti-clockwise until you  
get the water temperature of your liking.  
Wait 20 seconds after each adjustment  
Wait 20 seconds after each adjustment for  
for the water temperature to stablise.  
the water temperature to stabilise.  
If after turning fully anti-clockwise, water is  
still too hot, adjust outer knob “A” to  
“ (medium)” setting and re-adjust as above.  
5. Once a temperature setting to your liking  
has been achieved, inner knob “B” will rarely  
need adjusting. You must however take into  
account required adjustments for variations  
of incoming mains water temperature  
Water flow will be reduced on this setting.  
between summer and winter (see “Effect of Seasonal Incoming Water Temperature Changes”).  
6. When you have finished showering, turn outer knob “A” anti-clockwise to the “ (stop)”  
position. Water will continue to flow for up to 3 seconds before switching off.  
This reduces the temperature of the water in the tank for the next user.  
Switch off the electricity at the ceiling switch or local isolator.  
7. The “ (medium)” setting of outer knob “A” reduces the power used by the shower giving a  
cooler shower or the option of reduced water flow. This option is mainly used for summer usage  
and if this is used then inner knob “B” must be re-adjusted.  
8. The “ (cold)” setting of outer knob “A” will supply water without any heating, and the neon  
light will go out.  
9. Your shower is designed to stabilise temperature changes caused by water pressure  
fluctuations (see “Effect of Other Water Devices on Incoming Water Supply”).  
10. Note that inner knob “B” IS NOT A TAP and does not turn the water off.  
WARNING: DO NOT SWITCH THE SHOWER ON IF YOU SUSPECT IT OF BEING FROZEN.  
WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT.  
WARNING: DO NOT OPERATE THE SHOWER IF WATER LEAKS FROM THE PRESSURE  
RELIEF VALVE. MAINTENANCE IS REQUIRED BEFORE THE SHOWER CAN BE  
SAFELY USED.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING: CONSIDERATION SHOULD BE GIVEN TO SUPERVISING THE YOUNG, ELDERLY  
AND THE INFIRM WHILST THEY USE THIS SHOWER  
HOW YOUR ACTIVE 320S SHOWER WORKS  
1. Water is heated instantaneously as it flows over the  
heating elements in the copper cylinder (diagram 2).  
2. The heaters are only switched on when sufficient  
water is flowing.  
This is done automatically with a switch which works  
on water pressure and is indicated by the neon light  
illuminating depending on the power selected by  
outer knob “A”.  
3. The water is turned on and off by the solenoid valve  
built into the shower.  
This is switched on when outer knob “A” is clicked  
clockwise.  
4. The flow of water is automatically held at the level  
set by the user even though the supply pressure  
may vary (see “Effect of Other Water Devices on  
Incoming Water Supply”).  
5. If the water supply falls below a set limit, the pressure switch will operate and switch off the  
power to the elements. This is indicated by the neon light going out (see “Effect of Other Water  
Devices on Incoming Water Supply”).  
6. As a further safeguard, a thermal cut-out switches the power off if the water temperature  
climbs above the set limit. This cut-out, which gives an audible click, may also operate due to  
residual heat when the shower is switched off.  
It will reset itself if water is run through the shower for 10 to 20 seconds.  
7. The pressure relief device is to safeguard against abnormal pressure conditions.  
Effect of Seasonal Incoming Water Temperature Changes  
The required water temperature is achieved by adjusting the rate of water flow.  
Diagram 3 shows the principle involved in relating temperature rise to flow rate.  
The higher the water rate the lower the temperature and vice versa.  
The temperature of the water supplied from the mains can vary considerably  
throughout the year from 5 to 20°C.  
This means that in the winter, flow rate will be less than in the summer to  
achieve the same outlet temperature.  
In summer the “ (medium)” power setting may give adequate hot water.  
Effect of Other Water Devices on Incoming Water Supply  
Your shower is designed to stabilise temperature changes caused by water pressure  
fluctuations. These can result from toilets being flushed or taps being turned on and off.  
When this happens your showering temperature will be held within a controlled band, provided that  
the minimum pressure required by the shower is maintained.  
Your shower requires a minimum operating pressure of 69kPa (0.7 bar, 10 psi).  
At pressures above 69kPa (0.7 bar, 10 psi) it will minimise temperature fluctuations as detailed  
above. If the water pressure falls below 69kPa (0.7 bar, 10 psi) it is likely that the pressure switch  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
will turn off the power to the heating elements, resulting in a cold shower.  
This will be indicated by the neon light going out.  
HOW TO MAINTAIN YOUR ACTIVE 320S SHOWER  
It is recommended that the shower unit and hose etc. be cleaned using a soft cloth and that the use  
of abrasive or solvent cleaning fluid be avoided.  
We recommend that before any cleaning, the isolating switch be turned off, thus avoiding  
accidentally switching on the shower.  
WARNING: IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER,  
YOU MUST CLEAN THE SHOWER HANDSET REGULARLY  
All water contains particles of lime, which build up in the shower handset and unit reducing the  
performance.  
It is therefore important to clean the shower handset by simply rubbing the rubber nozzles.  
NOTE: After use it is normal for some water to drip from the shower handset for a few moments.  
This inhibits scale build-up over prolonged use.  
WHAT TO DO IF THINGS GO WRONG (1)  
SELF HELP  
If the shower is unsatisfactory, make the following checks before calling out the contractor.  
Any one of these adjustments could restore the performance.  
The shower cycles  
from HOT to COLD device) to operate.  
Turn inner knob “B” anti-clockwise in the direction of the “blue arrows” to  
The shower temperature is set too hot causing the thermal cut-out (safety  
increase water flow.  
Slowly increase the water temperature by turning inner knob “B” clockwise in  
the direction of the “red arrows” until a comfortable showering temperature has  
been reached.  
You MUST WAIT approximately 20 seconds for each adjustment to affect the  
water temperature.  
“ (medium)” setting may need to be selected.  
Water too HOT  
Water too COLD  
Increase water flow by adjusting inner knob “B” anti-clockwise (direction of the  
“blue arrows”).  
“ (medium)” setting may need to be selected.  
Increase pressure to water supply e.g. fully open service valve or stop cock.  
Check hose is not kinked restricting the water flow.  
Clean shower handset.  
Check power is on by neon being illuminated.  
Decrease water flow by adjusting inner knob “B” clockwise (direction of the “red  
arrows”).  
“ (high)” setting may need to be selected.  
Spray pattern poor Clean the shower handset.  
Water takes longer Thermal cut-out has operated after previous use  
to heat up  
(automatically resets when unit cools down)  
“ (high)” setting may need to be selected.  
Check neon light is on.  
Check water pressure has not fallen so far as to let pressure switch cut out,  
e.g. Another tap drawing water off.  
Water goes cold  
while using  
shower  
Raise position of shower handset.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Water continues to This is normal.  
flow when  
The shower includes a shutdown feature that means the water will continue to  
“ (stop)” selected flow for up to 3 seconds after “ (stop)” has been selected.  
Broken parts  
Please contact our spares department on 08709 000420 (UK only).  
Fitting instructions are provided with most spares  
WHAT TO DO IF THINGS GO WRONG (2)  
PROFESSIONAL SERVICE  
If the previous “Self Help” checks fail to restore the performance, you should seek professional help.  
The person who installed the shower is probably the best one to repair it and is certainly the person  
to contact if you have had a problem in the guarantee period.  
The following additional checklist is provided for the benefit of the qualified service person.  
WARNING: SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR  
BEFORE REMOVING THE COVER TO MAKE CHECKS  
Water too HOT  
Water flow restricted by blockage in filter of solenoid valve.  
Switch off water, loosen inlet connection to solenoid, remove filter in solenoid  
with long nosed pliers and flush clean.  
Water too COLD  
Check circuit through thermal cut-out.  
Check circuit through microswitches on the pressure switch.  
Check each element circuit.  
Check tightness of electrical connections.  
No control over  
water flow  
Check Drive Gite is correctly engaged into Control Knob (see diagram.9)  
Undo headworks of stabiliser valve.  
Check stabiliser is in place and remove any debris in valve.  
Water leaks from  
burst pressure  
relief valve  
Check for cause of high pressure and remove it.  
Blockage on outlet e.g. blocked shower handset.  
Replace the pressure relief disc (not covered by guarantee).  
Water does not  
flow when outer  
knob “A” is  
Check circuit through solenoid coil. If defective then replace.  
Check circuit through microswitches. If defective then replace.  
Power supply not reaching shower.  
turned.  
REDRING AFTER SALES SERVICE  
We offer a technical advisory service on the telephone to  
contractors and other customers with problems in the field.  
RING 08709 000430 (UK ONLY)  
RING YOUR LOCAL DEALER (Export Variants)  
Some spare parts (see later section) can be supplied  
against Credit or Debit cards.  
RING 08709 000420 (UK ONLY)  
Remember to quote the exact type of shower, as written on the  
front of the shower and on this leaflet.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
The model and serial number are located on the bottom face of the shower.  
Make a note of those numbers here, and be sure to quote them if you call for advice.  
Model Number: 53-67_ _ _ _ _ _ _ _ _ _ _ _ _ _  
Serial Number: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
HOW TO INSTALL YOUR ACTIVE 320S SHOWER  
WARNING: ALL WIRING AND INSTALLATION MUST BE  
SUPERVISED BY A SUITABLY QUALIFIED PERSON.  
WARNING: DO NOT INSTALL THIS SHOWER WHERE IT MAY BE  
SUBJECTED TO FREEZING CONDITIONS  
We recommend that the installation is done in the following sequence.  
a. Fixing the shower to the wall b. Plumbing c. Electrical connections  
a. FIXING THE SHOWER TO THE WALL  
1. Position the riser rail at the height recommended in diagram 5 and  
mark its position (also see separate accessories fitting instructions).  
2. Position the heater so that the top of the unit is horizontal and level  
with, or a maximum of 0.6 metres (2ft) below the top of the  
riser rail. Choose a flat piece of wall to avoid the possibility of  
distorting the backplate thus making the front cover a poor fit.  
3. Adjust the position to get the most convenient arrangement taking  
the following into account.  
·
·
·
The possible need to use the handset over the sink for hair washing etc.  
The heater must not be mounted in the direct spray from the handset.  
The handset must not be able to come into contact with used water in the cubicle, bath or  
basin. If it can, even after the hose has been retained by the soap dish (see separate  
accessories fitting instructions sheet) then a vacuum breaker must be fitted.  
4. Fix the riser rail with screws provided (see separate instructions supplied with accessories).  
5. Decide the position of the electrical cable into the unit. If top or bottom entry is chosen  
(according to diagram 4), cut away the walls in the backplate as shown in diagram 6.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Decide the position of entry of the cold water pipe into the unit.  
If top, cut away the backplate.  
If rear, please read the section on plumbing.  
If bottom, remove the front cover (complete with knobs) and cut away the detachable corner  
section as shown.  
7. If you have not yet done so, remove the front cover assembly by undoing the retaining screws at  
the top and bottom of the unit and lifting the cover off.  
Your shower is provided with 2 fixing positions in the backplate (see diagram 4).  
The top-fixing hole is a “key-hole” slot (another key-hole is provided for alternate fixing), and  
should be marked and drilled first.  
Tighten top screw with head protruding about 10mm from the wall and hook the backplate over  
the screw head. This allows for correct and accurate alignment of your shower before marking  
and fixing the bottom position.  
You may not wish to tighten up both screws at this stage as the holes are elongated to allow for  
adjustment after other connections have taken place.  
b. PLUMBING  
WARNING: ENSURE THAT THE MAINS WATER SUPPLY MEETS THE REQUIREMENTS  
BELOW BEFORE CONTINUING WITH INSTALLATION.  
The heater must be connected to the mains cold water supply.  
This must have a minimum running pressure of 69kPa (0.7 bar, 10 psi)  
and a maximum pressure of 690kPa (7.0 bar, 100 psi).  
WARNING: BEFORE CONNECTING THE PIPE WORK TO THE SHOWER,  
ENSURE THAT THE PIPE WORK IS FULLY FLUSHED OUT.  
1. Unscrew the “Red Cap” and “Washer” from the shower outlet pipe and discard them in a suitable  
manner. These have been used to seal the shower during transit, and are no longer required.  
2. It is recommended that a WRAS (Water Regulations Advisory Scheme) listed isolating valve is  
fitted between the rising main and the unit.  
This will allow the unit to be serviced or exchanged without having to turn off the water at the  
water stop valve.  
3. The heater can be fed from a header tank provided this has a minimum head of 7 metres (23ft).  
4. Ø15mm copper or stainless steel pipe should be used.  
To avoid cross threading, DO NOT REMOVE the nut from the elbow when positioning the pipe.  
If top entry is required, turn the elbow 180° into the required position.  
If rear entry is required, treat as top entry with an additional “Yorkshire” elbow (soldered type)  
for fitting into the rear channel.  
In multiple installations, correct pipe work sizes should be calculated to maintain adequate flow  
to each shower.  
5. It is in order to use a WRAS (Water Regulations Advisory Scheme) approved sealant sparingly  
whilst avoiding excess finding its way into the shower operating parts.  
6. With stop valve connected, flush the pipe work through to remove any particles etc,  
before making the final connection to the shower.  
Blockage in the water ways (particularly the handset and solenoid valve) will prevent the heater  
working properly.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. The shower is designed to have an open outlet and should only be used with ”Redring”  
recommended fittings.  
Do not connect the handset until after the shower front cover and corner section are fitted.  
WARNING: DO NOT FIT A TAP ON THE SHOWER OUTLET.  
WARNING: TAKE CARE TO AVOID RESTRICTING THE OUTLET OF THE  
PRESSURE RELIEF DEVICE  
c) ELECTRICAL  
WARNING: THIS SHOWER MUST BE EARTHED.  
The electrical installation must be in accordance with the current BS.7671 (IEE Wiring Regulations)  
and “Part P” of the Building Regulations and/or local regulations  
1. The SHOWER is designed for a single phase AC electrical supply.  
Please check the rating plate on the unit to see what details apply to your unit.  
AS A GUIDE ONLY (* Only applies if external earth impedance is less than 0.35 Ohms)  
Rating  
Cable Sizes  
4.0mm²  
Fuse / MCB  
Cable Length  
21m Max.  
32A Type B MCB  
6.0mm²  
35m Max.  
7.2 / 6.6kW 240 / 230V  
.
6.0mm²  
10.0mm²  
6.0mm²  
10.0mm²  
6.0mm²  
10.0mm²  
6.0mm²  
10.0mm²  
27m Max.  
45m Max.  
27m Max.  
45m Max.  
12m Max.*  
21m Max.*  
40A Type B MCB  
40A Type B MCB  
45A BS.1361 fuse  
40A Type B MCB  
45A BS.1361 fuse  
8.5 / 7.8kW 240 / 230V  
9.5 / 8.7kW 240 / 230V  
27m Max.  
45m Max.  
6.0mm²  
10.0mm²  
12m Max.*  
21m Max.*  
Remember to upgrade the cable if it runs in thermal insulation in a loft, or for a longer distance.  
2. A means for disconnection in all poles must be incorporated in the fixed wiring in accordance  
with the wiring rules.  
We recommend a ceiling switch mounted in a convenient position.  
3. Cut back cable as in diagram 7. Connect cable to terminal block making sure that all the  
retaining screws are VERY TIGHT and  
that no cable insulation is trapped under  
the screws.  
WARNING: FAILURE TO COMPLY WITH  
THESE INSTRUCTIONS  
COULD RESULT IN FAILURE  
OF THE TERMINAL BLOCK  
4. Re-Fit the corner section back into the  
backplate.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Re-Fit the front cover (see diagram 9)  
a. Ensure outer knob “A” is aligned fully anti-clockwise to the “ (stop)“ position.  
b. Ensure inner knob “B” is aligned to the “ (high)” position.  
c. In the main body of the shower, turn the “Drive Spider” fully anti-clockwise until it stops.  
d. In the main body of the shower, turn the “Drive Gite” anti-clockwise until it is at “12 o’clock”.  
e. Fit the front cover of the shower to the main body ensuring that the 3 x “Drive Spider Legs”  
engage with the slots in outer knob “A”.  
f. Check that outer knob “A” has been correctly aligned by ensuring that all 3 power settings can  
be selected, and returns to the “ (stop)“ position.  
g. Check that inner knob “B” has been correctly aligned by turning clockwise and ensuring that  
knob turns approximately 3/4 of a turn (270°) and when turned back fully anti-clockwise,  
returns to the “ (high)” position.  
6. Replace the top and bottom fastening screws.  
7. Fit the shower hose, and operate the shower first without the handset to flush out particles,  
fit the handset and then operate the shower as on page 3 or 12 and check:  
a.  
b.  
c.  
That the water gets to a satisfactory temperature.  
Water flow can be adjusted by inner control knob “B”.  
Power selection operates in all 3 positions, giving a change in water temperature and  
that the neon light functions correctly.  
d.  
e.  
Check again for leaks  
That the holes in the shower handset are not blocked  
Download from Www.Somanuals.co1m0. All Manuals Search And Download.  
8. DEMONSTRATE OPERATION TO USER  
ADDITIONAL ACCESSORIES  
SPARE PARTS  
Please Note:- The fitting of Spare Parts must be supervised by a suitably qualified person.  
White 2 metre Shower Hose  
WRAS Water Isolating Valve  
Cat No. 83792578 Front Cover  
Cat No. 93792452 Tank-Base Assy (7.2kW) Cat No. 93597858  
Cat No. 93597856  
Chrome Multi-Mode Accessories Cat No. 83595318 Tank-Base Assy (8.5kW) Cat No. 93597859  
Chrome Premium Accessories  
Chrome Curved Accessories  
Curtain and Rail Pack  
Curtain and Rail Pack with  
Non-Slip Mat  
Cat No. 83595319 Solenoid Valve  
Cat No. 83595320 Neon Cable Assy  
Cat No. 83792812 Tank Clip  
PRV Washer  
Cat No. 93597868  
Cat No. 93590506  
Cat No. 93590715  
Cat No. 93795817  
Cat No. 93795809  
Cat No. 83792811 Cylinder “O”-Ring  
Thermal Cut-Out 50/88°C Cat No. 93597871  
Additional accessories and spare parts can be  
supplied against any Credit or Debit cards  
from Redring Sales Hotline 08709 000420  
Handset  
Height Adjuster  
Cat No. 93597860  
Cat No. 93597861  
:
GUARANTEE AND CONTACT DETAILS  
Download from Www.Somanuals.co1m1. All Manuals Search And Download.  
Full details of terms and conditions are available on request from:-  
APPLIED ENERGY PRODUCTS LIMITED  
MORLEY WAY, PETERBOROUGH PE2 9JJ  
TEL: +44 (0) 1733 456789  
FAX: +44 (0) 1733 310606  
HOW TO USE YOUR ACTIVE 320S SHOWER (SUMMARY)  
1. Ensure the electricity and water are turned on to the unit.  
2. Turn outer knob “A” clockwise to the “Power Select”  
position of your choice.  
The water will flow, and the neon indicator light will glow.  
= High Power  
= Medium Power  
= Cold Shower  
3. Turn inner knob “B” a small amount until you reach  
the desired showering temperature.  
Turn anti-clockwise (follow blue arrows) for cooler.  
Turn clockwise (follow red arrows) for warmer.  
4. When you have finished showering, turn outer knob “A” anti-clockwise to the “ ” position.  
(You have no need to adjust inner knob “B”).  
5. Water will continue to flow for up to 3 seconds before switching off.  
This reduces the temperature of the water in the tank for the next user.  
The neon indicator light will go out.  
6. Switch off the electricity supply at the ceiling switch or local isolator.  
Notes  
·
·
Wait 20 seconds for the temperature to stabilise after each adjustment.  
The neon indicates when the heaters are on and, if the shower has been recently  
used, can take up to 20 seconds to come on.  
During this time the water may go from very hot to cold before stabilising.  
Also, please note that the neon indicator does not light when the shower is set to the  
“ cold power setting.  
Download from Www.Somanuals.co1m2. All Manuals Search And Download.  
·
·
The position of inner knob “B” will be approximately the same each time the shower  
is used, varying only with incoming water temperature or pressure changes  
(e.g. you will only need to change from summer to winter).  
During normal operation, if an overheated water temperature is sensed then the  
heater will switch off and the neon indicator will go out.  
The water will continue to flow and cool down before the heater switches back on  
again.  
IMPORTANT WARNINGS!  
DO NOT SWITCH THE APPLIANCE ON IF YOU SUSPECT IT OF BEING FROZEN.  
WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT.  
DO NOT OPERATE THE APPLIANCE IF WATER LEAKS FROM THE PRESSURE RELIEF  
VALVE. MAINTENANCE IS REQUIRED BEFORE THE APPLIANCE CAN BE SAFELY USED.  
CONSIDERATION SHOULD BE GIVEN TO SUPERVISING THE YOUNG, ELDERLY AND  
THE INFIRM WHILST THEY USE THIS APPLIANCE  
Leaflet No. 555-2136-01B  
Download from Www.Somanuals.co1m3. All Manuals Search And Download.  

Radio Shack Caller ID Box CID 932 User Guide
Radio Shack Home Security System 49 2570 User Guide
Radio Shack Scanner 200 0113 User Guide
Ricoh PDAs Smartphones EL 6991 User Guide
Rolls Power Supply RPB486 User Guide
Saitek Switch Hi Speed USB 20 Hub User Guide
Samson Musical Toy Instrument Conspiracy User Guide
Sanus Systems Indoor Furnishings WMS3 User Guide
Sanyo Flat Panel Television LCD 19XR9DA User Guide
Sanyo Vacuum Cleaner SC L180H User Guide