Quadra Fire Indoor Fireplace QV32E B User Guide

Owner’s Manual  
Installation and Operation  
Models:  
QV32E-B  
QV32EV-B  
Electric Fireplace  
Shown with door front.  
Door front not shipped with heater.  
DO  
DISCARD  
NOT  
CAUTION  
DO NOT DISCARD THIS MANUAL  
Read, understand  
and follow these  
instructions for safe  
installation and  
operation.  
Leave this manual with  
Important operating  
party responsible for  
use and operation.  
and maintenance  
instructions included.  
WARNING  
WARNING  
HOT! DO NOT TOUCH.  
If the information in these instruc-  
tions is not followed exactly, a  
fire may result causing property  
damage, personal injury, or death.  
SEVERE BURNS MAY RESULT.  
CLOTHING IGNITION MAY RESULT.  
Glass and other surfaces are hot  
during operation and cool down.  
• Do not store or use gasoline or other flam-  
mable vapors and liquids in the vicinity of  
this or any other appliance.  
• Comply with all minimum clearances to  
combustibles as specified. Failure to  
comply may cause house fire.  
Keep children away.  
CAREFULLY SUPERVISE children in same room  
as heater.  
Alert children and adults to hazards of high  
temperatures.  
Keep clothing, furniture, draperies and other  
combustibles away.  
Made in China  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
1
2
Listing and Code Approvals  
4
8
Operating Instructions  
15  
A. Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
A. Manual Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  
B. Hand Held Remote Control Transmitter . . . . . . . . . . 16  
C. Wall Switch Control . . . . . . . . . . . . . . . . . . . . . . . . . . 17  
D. FCC Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 17  
Getting Started  
5
A. Important Instructions . . . . . . . . . . . . . . . . . . . . . . . . . 5  
B. Design and Installation Considerations. . . . . . . . . . . . 6  
C. Tools and Supplies Needed. . . . . . . . . . . . . . . . . . . . . 6  
D. Inspect Heater and Components. . . . . . . . . . . . . . . . . 6  
9
Troubleshooting  
A. Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . 18  
18  
3
4
Framing and Clearances  
7
10 Maintenance and Service  
19  
A. Selecting Heater Location . . . . . . . . . . . . . . . . . . . . . . 7  
B. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
C. Framing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
A. Cleaning the Firebox and Control Compartment. . . . 19  
B. Cleaning the Back Acrylic Panel. . . . . . . . . . . . . . . . 19  
C. Replacing the Light Bulbs . . . . . . . . . . . . . . . . . . . . . 19  
D. Heater/Blower Assembly Maintenance . . . . . . . . . . . 20  
E. Maintenance Task List. . . . . . . . . . . . . . . . . . . . . . . . 20  
Wiring  
9
A. 120VAC Wall Outlet Installation. . . . . . . . . . . . . . . . . . 9  
B. 120VAC Hardwire Installation . . . . . . . . . . . . . . . . . . . 9  
C. 240VAC Hardwire Installation . . . . . . . . . . . . . . . . . . 10  
D. Wall Switch Wiring (12VDC) . . . . . . . . . . . . . . . . . . . 10  
11 Reference Materials  
21  
A. Heater Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
B. Optional Components . . . . . . . . . . . . . . . . . . . . . . . . 22  
C. Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
D. Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27  
E. Contact Information. . . . . . . . . . . . . . . . . . . . . . . . . . 28  
5
6
Heater Preparation  
A. Secure and Level the Heater. . . . . . . . . . . . . . . . . . . 11  
11  
Finishing  
12  
A. Finishing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
B. Finishing Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
C. Mantel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
7
Heater Setup  
14  
A. Remove Shipping Materials . . . . . . . . . . . . . . . . . . . 14  
B. Clean Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
C. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
D. Install Refractory . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
Note: An arrow () found in the text signifies change in content.  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Listing and Code Approvals  
1
A. Certification  
This heater has been tested in accordance with the UL2021  
Standards for fixed and location-dedicated electric room  
heaters in the United States, the current CSA C22.2 No. 46  
in Canada and has been listed by Underwriters Laboratories  
Inc. for installation as described in this manual. All compo-  
nents are UL or CSA safety certified.  
This heater has been tested and listed for use with the op-  
tional components specified in this manual. These optional  
components may be purchased separately and installed at  
a later date.  
Quadra-Fire is a registered trademark of Hearth & Home  
Technologies Inc.  
4
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
2
WARNING  
Fire Risk!  
WARNING  
Improper installation, adjustment, alteration, service  
or maintenance can cause injury or property damage.  
Refer to the owner’s information manual provided with  
this heater. For assistance or additional information  
consult a qualified installer, service agency or your  
dealer.  
Do not install or operate damaged  
heater.  
Do not modify heater.  
Installation other than as instructed by  
Hearth & Home Technologies Inc. is  
strictly prohibited.  
Do not operate the heater without fully  
assembling all components.  
Installation and/or use of any component  
part not approved by Hearth & Home  
Technologies.  
Not intended for use as a primary heat source.  
This heater is tested and approved as a decorative heater.  
It should not be factored as a primary heat source in  
residential heating calculations.  
Hearth & Home Technologies disclaims any responsibility  
for, and the warranty and agency listing will be voided by  
the above actions.  
Do not insert or allow foreign objects to enter any ventilation  
or exhaust opening as this may cause an electric shock  
or fire, or damage the heater.  
To prevent a possible fire, do not block air intakes or  
exhaust in any manner.  
A. Important Instructions  
When using electrical heaters, basic precautions should al-  
ways be followed to reduce the risk of fire, electric shock,  
and injury to persons, including the following:  
Read all instructions before using this heater.  
This heater is hot when in use. To avoid burns, do not let  
bare skin touch hot surfaces. If provided, use handles  
when moving this heater. Keep combustible materials,  
such as furniture, pillows, bedding, papers, clothes, and  
curtains at least 12 in. (305 mm) from the front of the  
heater and keep them away from the sides and rear.  
Extreme caution is necessary when any heater is used  
by or near children or invalids and whenever the heater  
is left operating and unattended.  
A heater has hot and arcing or sparking parts inside. Do  
not use it in areas where gasoline, paint, or flammable  
liquids are used or stored.  
Use this heater only as described in this manual.Any other  
use not recommended by the manufacturer may cause  
fire, electric shock, or injury to persons.  
Avoid the use of an extension cord because the extension  
cord may overheat and cause a risk of fire. However, if you  
have to use an extension cord, the cord shall be No. 16  
AWG minimum size and rated not less than 1875 watts.  
Use minimum length and do not coil cord.  
Always use properly grounded fused and polarized  
outlets.  
Always use ground fault protection where required by  
electrical code.  
Always disconnect power before performing any cleaning,  
maintenance or relocation of the heater.  
To prevent a possible fire, do not burn wood or other  
materials in this heater.  
To prevent electric shock or fire, always use a certified  
electrician should new circuits or outlets be required.  
When transporting or storing the heater, keep in a dry  
place free from excessive vibration and store as to avoid  
damage.  
Always unplug heater when not in use.  
Do not operate any heater with a damaged cord or plug  
or after the heater malfunctions, has been dropped or  
damaged in any manner. Return heater to authorized  
service facility for examination, electrical or mechanical  
adjustment, or repair.  
Do not use outdoors.  
This heater is not intended for use in bathrooms, laundry  
areas and similar indoor locations. Never locate heater  
where it may fall into a bathtub or other water container.  
Do not run cord under carpeting. Do not cover cord with  
throw rugs, runners, or the like. Arrange cord away from  
traffic area and where it will not be tripped over. Do not  
coil cord.  
To disconnect heater, turn controls to “OFF”, then remove  
plug from outlet.  
SAVE THESE INSTRUCTIONS FOR FUTURE  
REFERENCE.  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. Design and Installation Considerations  
D. Inspect Heater and Components  
CAUTION  
CAUTION  
Check building codes prior to installation.  
Sharp Edges  
Installation MUST comply with local, regional,  
Wear protective gloves  
and safety glasses during  
installation.  
state and national codes and regulations.  
Consult insurance carrier, local building inspector,  
fire officials or authorities having jurisdiction about  
restrictions, installation inspection, and permits.  
When planning a heater installation, it is necessary to deter-  
mine the following information before installing:  
WARNING  
Fire Risk  
Where the heater is to be installed. See Sections  
3 and 4.  
Inspect heater and components for damage.  
Damaged parts may impair safe operation.  
Electrical wiring. See Section 4.  
Do NOT install damaged components.  
Do NOT install incomplete components.  
Do NOT install substitute components  
Framing and finishing details. See Sections 3 and 6.  
Whether optional accessories—devices such as a fan, wall  
switch or remote control—are desired. See Section 11.  
Report damaged parts to dealer.  
C. Tools and Supplies Needed  
Before beginning the installation be sure the following tools  
and building supplies are available:  
Carefully remove the heater and components from the  
packaging.  
Report to your dealer any parts damaged in shipment.  
Read all the instructions before starting the installation.  
Follow these instructions carefully during the  
installation to ensure maximum safety and benefit.  
Reciprocating saw  
Pliers  
Framing material  
Wall-finishing materials  
Gloves  
Hammer  
Phillips screwdriver  
Flat blade screwdriver Electric drill and bits  
Framing square  
Plumb line  
Level  
Surround  
Safety glasses  
Tape measure  
1/2-3/4 in. length, #6 or #8 self-drilling screws  
Misc. screws and nails  
Note:  
Illustrations and photos reflect typical installations  
and are FOR DESIGN PURPOSES ONLY.  
Illustrations/diagrams are not drawn to scale.  
Actual installation/appearance may vary due to  
individual design preference.  
CAUTION  
Hearth & Home Technologies reserves the right to  
Keep heater dry.  
Mold or rust may cause odors.  
alter its products.  
Note: Minimum and maximum clearances must be  
maintained at all times. Illustrations throughout these  
instructions reflect typical installations and are for design  
purposes only. Actual installation may vary slightly due to  
individual design preferences.  
The illustrations and diagrams used throughout these  
installation instructions are not drawn to scale.  
6
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Framing and Clearances  
WARNING  
3
Note: Minimum and maximum clearances must be  
maintained at all times. Illustrations throughout these  
instructions reflect typical installations and are for design  
purposes only. Actual installation may vary slightly due to  
individual design preferences.  
Fire Risk  
Provide adequate clearances.  
Around air openings  
To combustibles  
For service access.  
The illustrations and diagrams used throughout these  
installation instructions are not drawn to scale.  
Locate heater away from traffic areas.  
A. Selecting Heater Location  
B. Clearances  
Several options are available to you when choosing a loca- Figure 3.1 shows all clearances that must be maintained  
tion for your heater. This heater may be used as a room around the heater.  
divider, installed along a wall, across a corner or used in an  
exterior chase. See Figure 3.1. This heater may be installed  
directly on the floor, carpet or raised on a hearth.  
WARNING  
Fire Risk  
Due to high temperature, this heater should  
DANGER  
be located out of high traffic areas.  
Electrocution Risk  
Keep combustible materials such as  
furniture, pillows, bedding, papers,  
clothes and curtains at least 12 in.  
(305 mm) from the front of the heater.  
NEVER locate this heater where it may fall  
into a bathtub or other water container.  
Contact local building administrator for  
information on bathroom intallations.  
WARNING  
Fire Risk!  
31-7/8 in.  
(810 mm)  
Prevent contact with sagging, loose  
insulation.  
Do NOT install against vapor barriers or  
exposed insulation.  
36-1/4 in.  
(921 mm)  
22-1/2 in.  
(572 mm)  
14 in.  
45 in.  
(356 mm)  
WARNING  
(1143 mm)  
Do NOT use this heater if any part has been under water.  
Immediately call a qualified service technician to inspect  
the heater and to replace any part of the control system  
which has been under water.  
36-1/4 in.  
(921 mm)  
36-1/4 in.  
(921mm)  
14 in.  
(356 mm)  
WARNING  
1 in.(26 mm)min.  
Fire Risk  
Comply with all minimum clearances to  
combustibles as specified.  
Figure 3.1 Heater Locations  
Failure to comply may cause fire.  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
C. Framing  
Figure 3.2 shows a typical framing (using 2 x 4 lumber) of  
the heater, assuming combustible materials are used. All re-  
quired clearances to combustibles around the heater must  
be adhered to.  
(CEILING)  
30 in. min.  
(762 mm)  
3/4 in. - 12 in.  
(19 mm - 305 mm)  
31-1/4 in.*  
31-1/2 in.  
(794 mm)  
(800 mm)  
Header Height  
Mantel height listed is measured  
from the BASE of the heater.  
36-1/4 in.*  
(921 mm)  
*If using the PBT or BKT Cabinet Trim Kits,  
increase the width by 1-1/4 in. (32 mm) and  
header height by 5/8 in. (16 mm).  
14 in.  
(356 mm)  
Figure 3.2 Framing the Heater  
8
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring  
4
Amps  
WARNING  
Shock Risk  
Fire Risk  
Model  
Description  
31 in. fireplace  
31 in. fireplace  
Voltage  
120  
Watts  
1400  
(120/240)  
QV32E-B  
12.5  
QV32EV-B  
240  
2600  
12.5  
Improperly protected power cords could  
cause electrical shock or fire.  
Note: Follow all national and local electrical codes.  
Do not pinch the cord or lay against a  
sharp object.  
Do not cover the cord with carpeting, throw  
Note: This heater must be electrically wired and grounded  
in accordance with local codes or, in the absence of local  
codes, with National Electric Code ANSI/NFPA 70-latest  
edition or the Canadian Electric Code, CSA C2.1 as  
appropriate.  
rugs or runners.  
Secure and arrange cord to avoid a  
tripping hazard.  
Do not coil cord.  
WARNING  
Shock Risk  
All wiring must be done by a qualified electrician.  
Use appropriate wire to meet local and national  
codes for rated power consumption.  
Improperly grounded outlets could cause  
electrical shock.  
Always use properly grounded, fused and  
polarized outlets.  
CAUTION  
Always used ground fault protection where  
required by electrical code.  
Label all wires prior to disconnection when servicing  
controls. Wiring errors can cause improper and dangerous  
operation. Verify proper operation after servicing.  
CAUTION  
Disconnect remote controls during your extended absence.  
This will prevent accidental operation of the heater.  
A. 120VAC Wall Outlet Installation  
The heater is The heater is wired from factory with a  
polarized plug.  
For ease of electrical hook up, you may wish to install the  
heater near an existing outlet. A15 amp, 120 volt circuit is  
required. A dedicated circuit is preferred but not essential  
in all cases. A dedicated circuit will be required if, after  
installation, the circuit trips or fuse blows on a regular  
basis when the heater is operated. Additional appliances  
on the same circuit may exceed the current rating of the  
circuit breaker.  
Before plugging heater into wall outlet, make sure all  
control switches are in the “OFF” position. To access  
the controls, lift up on the lower grille panel and rotate it  
forward.  
B. 120VAC Hardwire Installation  
Turn off circuit breaker.  
Access knockout.  
Remove the access cover plate.  
Disconnect the power cord from the terminal block.  
Remove the knockout and install the cable clamp (not  
provided) into the hole.  
Feed 8 in. of service wire through the cable clamp and  
secure.  
Connect the black wire from the service to the L1  
terminal.  
Connect the white wire from the service to the N  
terminal.  
Connect the green (ground) from the service to the GND  
terminal.  
If the power cord is not being used, go to Step B below. If  
the cord does not reach the outlet, a No. 16-AWG minimum  
wire size extension cord rated for a minimum of 1875 watts  
may be used. Use minimum length and do not coil cord.  
Optional wall switch wiring is to be done at this time.  
Replace access cover plate.  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
C. 240VAC Hardwire Installation  
D. Wall Switch Wiring (12VDC)  
Turn off circuit breaker.  
*Do not connect wires to 120/240VAC* (hardwired heat-  
ers only)  
Access knockout.  
Remove the access cover plate.  
Disconnect the power cord from the terminal block.  
Remove the knockout and install the cable clamp (not  
provided) into the hole.  
Turn off circuit breaker.  
Access knockout.  
Remove the access cover plate.  
Feed 16 in. of service wire through the cable clamp and  
secure.  
Feed 8 in. of service wire through the cable clamp and  
secure.  
Low voltage wire can be used for the wall switch  
connection.  
Locate the loop of blue wire on the accessory  
connector.  
Cut the loop and connect one side to one of the wall switch  
wires and the other side to the other wire for the switch.  
Replace the access cover plate.  
Run the wall switch wire to the wall box and connect to a  
wall switch (WSK-21 & WSK-21-W)..  
Connect the black wire from the service to the L1  
terminal.  
Connect the red wire from the service to the L2  
terminal.  
Connect the white wire from the service to the N  
terminal.  
Connect the green (ground) from the service to the GND  
terminal.  
Optional wall switch wiring is to be done at this time.  
Replace access cover plate.  
LAMP  
LAMP  
FLAME M0TOR  
-12VDC  
A
B
120 VAC  
LAMPS  
R2  
SPEED  
CONTROL  
DIMMER  
OPTIONAL  
THERMOSTAT  
RELAY  
D1  
DIODE  
REMOTE HEAT  
CONTROL  
REMOTE OR  
WALL ON/OFF  
SWITCH  
B
A
HEAT SWITCH  
+
-
12VDC  
SUPPLY  
BLOWER  
WHITE  
BLOWER  
PE  
N
POWER  
BLOWER  
120 VAC  
HIGH LIMIT  
BLACK  
RED  
HEATER 1  
HEATER 2  
120 V  
240 V  
HIGH LIMIT  
HEATER 1  
-12VDC  
BLACK  
L1  
240 VAC  
120 V  
RED  
L2  
3 PIN WIRING  
HARNESS  
POWER NEUTRAL MUST NOT  
CONNECT TO VIRTUAL NEUTRAL  
OF HEATERS OR BLOWER IN  
240VAC VERSION  
TERMINAL STRIP  
120 VAC PLUG OR 120/240  
HARD WIRED  
120VAC - 240VAC 60 HZ SPLIT-PHASE  
Figure 4.1 120V/240V Wiring Diagram  
10  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heater Preparation  
5
A. Secure and Level the Heater  
Note: Follow all national and local electrical codes.  
WARNING  
Fire Risk!  
Note: Select a suitable location that is not susceptible  
to moisture and is away from drapes, furniture and high  
traffic areas.  
Prevent contact with sagging, loose  
insulation.  
Do NOT install against vapor barriers or  
exposed insulation.  
WARNING  
Shock Risk  
The diagram shows how to properly position, level, and se-  
cure the heater (see Figure 5.1). Nailing tabs are provided to  
secure the heater to the framing members.  
Improperly grounded outlets could cause  
electrical shock.  
Place the heater into position.  
Level the heater from side to side and front to back.  
Shim the heater as necessary.  
Bend out nailing tabs on each side.  
Keep nailing tabs flush with the framing.  
Secure the heater to the framing by using nails or screws  
through the nailing tabs.  
Always use properly grounded, fused and  
polarized outlets.  
Always use ground fault protection where  
required by electrical code.  
WARNING  
Shock Risk  
Fire Risk  
Improperly protected power cords could cause  
electrical shock or fire.  
Do not pinch the cord or lay against a  
sharp object.  
Do not cover the cord with carpeting, throw  
rugs or runners.  
Arrange and secure cord to avoid a tripping  
hazard.  
WARNING  
Fire Risk  
Nailing Flanges  
(both sides)  
Do not install or operate damaged heater.  
Do not modify heater.  
Installation other than as instructed by Hearth & Home  
Technologies Inc. is strictly prohibited.  
Do not operate the heater without fully assembling all  
components.  
Figure 5.1 Proper Positioning, Leveling and Securing Heater  
Installation and/or use of any component part not  
approved by Hearth & Home Technologies.  
Hearth & Home Technologies disclaims any responsibility  
for, and the warranty and agency listing will be voided by  
the above actions.  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Finishing  
6
A. Finishing Material  
Note: Finishing materials are normally installed behind  
the nailing flanges or up to the sides of the nailing flanges.  
Allow room for the front to be added and the heater to be  
anchored.  
Combustible Material  
Material which is made of or surfaced with wood,  
compressed paper, plant fibers, plastics, or any material  
capable of igniting and burning, whether flame proofed or  
not, plastered or not plastered.  
Non-Combustible Material  
Material which will not ignite and burn. Such materials are  
those consisting entirely of steel, iron, brick, tile, concrete,  
slate, glass or plasters, or any combination thereof.  
1/2 in.  
(13 mm)  
Combustible  
Finishing  
Material  
stud  
(top view)  
appliance face  
drywall  
combustible  
material  
Figure 6.2 Finishing-Top View (120V)  
Figure 6.1 Finishing Materials  
B. Finishing Checklist  
Power supply service must be either completed or placed  
within the heater prior to finishing to avoid reconstruction.  
Wall switch wires (hardwired heaters only) must also  
be completed to avoid reconstruction. See Section  
“4. Wiring”.  
stud  
(top view)  
Combustible material may cover the black outer surface  
by 1/2 in. on the 120V heaters only. See Figure 6.2.  
Combustible material may not cover the black outer  
surface on 240V heaters. See Figure 6.3  
Grilles and air openings cannot be covered in any  
circumstances.  
Noncombustible material may cover all black outer  
surfaces. Grilles and air openings may not be covered.  
Protective cover may stay on during framing, but must  
be removed before final finishing. Once final finishing  
has been completed, the protective cover can be used to  
protect heater until final installation is complete.  
appliance face  
drywall  
combustible  
material  
Figure 6.3 Finishing-Top View (240V)  
Note: The heater is a zero clearance fireplace and may  
be finished with combustible or noncombustible finishing  
materials.  
When using paint or lacquer to finish the mantel, they must  
be heat-resistant to prevent discoloration.  
12  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C. Mantel  
(CEILING)  
30 in. min.  
(762 mm)  
3/4 in. - 12 in.  
(19 mm - 305 mm)  
35 in.  
(889 mm)  
Mantel height listed is measured  
from the BASE of the heater.  
Figure 6.4 Mantel Specifications  
WARNING  
Fire Risk  
Do NOT obstruct air inlet or outlet grilles.  
Do NOT modify grilles.  
Modifying or covering grilles could cause  
temperature rise and fire hazard.  
Finishing materials must not interfere with:  
Air flow through grilles or louvers  
Operation of louvers or doors  
Access for service  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heater Setup  
7
A. Remove Shipping Materials  
Remove shipping pack from front of fireplace taking care  
not to damage grate. See Figure 7.1.  
Remove grate from shipping pack and set aside. Discard  
shipping pack.  
Cut and discard the ties bundling the firescreen.  
Remove screws holding ember bed shipping tabs in  
place.  
Remove the tabs and discard. Replace the screws.  
Figure 7.1 Shipping Pack  
B. Clean Heater  
The heater was cleaned at the factory but dust may have  
accumulated during shipping.  
Vacuum firebox area and wipe acrylic panel (in back of  
firebox) with a dry, lint-free cloth or paper towel. DO NOT  
USE GLASS CLEANER! It will ruin the acrylic panel.  
Remove all fingerprints and smudges from front trim to  
avoid permanently burning them into finish.  
C. Accessories  
Refer to instructions included with accessory.  
D. Install Refractory  
Remove protective cover to access final installation items.  
Figure 7.2 Sliding Side Refractory Behind Bracket  
(right side shown)  
Remove Log Assembly  
Lift log set straight up and place in safe place.  
Log tabs  
Install Side Refractory  
Remove the refractory and fasteners from the carton.  
Take the refractory support bracket and bend it until it is  
L-shaped.  
Install the bracket to the underside of the firebox top using  
the screws provided. Keep the bracket loose to allow the  
refractory to slide in behind it.  
Tilt the side refractory into the heater and slide it behind  
Grate placement holes  
Figure 7.3 Install Grate  
the bracket. See Figure 7.2.  
Tighten the bracket when the refractory is resting on the  
hearth and is up against the back acrylic panel.  
Repeat for the other side.  
Install Grate  
Place grate legs into corresponding holes in ember bed,  
andirons to front. See Figure 7.3.  
Reinstall Logs  
Slide log brackets over tabs located on back of ember  
bed. See Figure 7.4.  
Figure 7.4 Install Logs  
14  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
8
-
It is recommended that during long periods of non-  
usage that the main power switch is turned to the “OFF”  
position.  
WARNING  
Flame/Ember Bed Intensity Control  
Fire Risk  
-
Turn the control knob clockwise to increase the  
intensity.  
Do not operate heater before reading and  
understanding operating instructions.  
-
Turn the control knob counter-clockwise to reduce the  
intensity.  
Failure to operate heater properly may  
cause fire.  
Flame/Ember Bed Motion Control  
-
Turn the control knob clockwise to increase the  
motion.  
-
Turn the control knob counter-clockwise to reduce the  
motion.  
A. Manual Controls  
Access Controls  
Heater/Blower Assembly Switch  
-
The heater/blower assembly will operate only if the  
switch is turned on.  
Controls are located behind the lower grille panel. To  
access the controls, lift up on the lower grille panel and  
rotate it forward.  
-
When the heater/blower assembly switch is in the  
“OFF” position, the heater can operate with flame but  
no heat.  
Function of Manual Controls  
Main Power Switch  
-
Main power switch is used to provide power to all  
controls. When the main power switch is on, the heater  
is turned on by the manual control on the heater,  
the remote control (optional) and/or the wall switch  
(optional).  
-
When the main power switch is off, the manual  
switches, remote control and wall switch will not  
work.  
HEATER/BLOWER ASSEMBLY SWITCH  
MAIN POWER SWITCH  
LEARN  
MOTION  
HEATER  
MAIN  
POWER  
LEARN  
MOTION  
INTENSITY THERMOSTAT  
THERMOSTAT  
INTENSITY  
Figure 8.1 Dashboard Controls  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
Odors and vapors released during initial  
operation.  
WARNING  
HOT! DO NOT TOUCH.  
SEVERE BURNS MAY RESULT.  
CLOTHING IGNITION MAY RESULT.  
Curing of high temperature paint.  
Open windows for air circulation.  
Glass and other surfaces are hot during  
operation and cool down.  
Odors may be irritating to sensitive individuals.  
Keep children away.  
CAREFULLY SUPERVISE children in same room as  
heater.  
Alert children and adults to hazards of high  
temperatures.  
Do NOT operate with protective barriers removed.  
Keep clothing, furniture, draperies and other  
combustibles away.  
WARNING  
Fire Risk  
All electric heaters have hot and arcing or  
sparking parts inside.  
Keep combustible materials, gasoline  
and other flammable vapors and liquids  
clear of heater.  
Do NOT store flammable materials close  
to heater.  
B. Hand Held Remote Control Transmitter  
RCE-QUAD-B (Optional)  
Keep all such liquids well away from the  
heater while it is in use.  
Combustible materials may ignite.  
The RCE-QUAD-B is an optional accessory listed with the  
Crestfire Series heaters.  
The transmitter is a radio frequency remote control. The  
frequency can be found on the back side of the transmitter.  
The range of the transmitter is approximately 20 ft (6.1 m)  
from heater.  
When the remote LED light is RED, the heater has been  
turned on or off by the remote transmitter. The manual  
controls located on the dashboard will override any other  
external controls (remote control/wall switch) used to  
operate the heater.  
Hand Held Remote Transmitter/Heater Initialization  
-
The transmitter operates on a 12V battery (included)  
made specifically for remote controls and electronic  
lighters. Install the 12V battery supplied with the heater  
into the battery compartment of the hand held remote  
transmitter. It is recommended that alkaline batteries  
always be used for longer battery life and maximum  
operational performance. If the signal light does not  
illuminate (when it normally would), check the position  
of the transmitter’s battery.  
-
-
-
Initialization only has to be done once.  
Turn the main power switch on.  
Locate the LEARN button on the dashboard. The  
LEARN button is located behind the lower grille/panel.  
To push the button, use a blunt object (such as a  
pencil).  
-
-
Push the button in and release. The heater will  
beep.  
Push and hold either the ON or OFF button on the hand  
held remote transmitter.Abeep will indicate heater and  
remote have been initialized.  
16  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Transmitter Function  
D. FCC Requirements  
-
The hand held remote transmitter is only an ON/OFF  
control. When the transmitter is active, the remote  
LED light will be RED. Upon initial use, there may be  
a delay of three seconds before the remote receiver will  
respond to the transmitter. This is part of the system’s  
design.  
If this equipment does cause harmful interference to radio  
or television reception, which can be determined by turn-  
ing the equipment off and on, the user is encouraged to try  
to correct the interference by one or more of the following  
measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and the  
receiver.  
-
With the main power switch (located on the heater  
system) in the “ON” position, press the ON button on  
the hand held remote transmitter to turn on the heater.  
The transmitter does not control/change the other  
switches or controls located on the heater. Features  
of the heater (flame motion and heater system) will  
remain in their last set position. If you would like to  
change the setting you will have to access the manual  
controls (located on the heater) to set the desired  
position.  
Connect the equipment into an outlet on a circuit different  
from that to which the receiver is connected.  
Consult the dealer or an experienced radio or TV technician  
for help.  
Canadian Equipment Requirements  
This digital apparatus does not exceed the Class A/Class B  
limits for radio noise emissions from digital apparatus set  
out in the Radio Interference Regulations of the Canadian  
Department of Communications.  
-
To turn off the heater, press the OFF button on the  
hand held remote transmitter.  
C. Wall Switch Control  
This device complies with RSS-210 of Industry and Science  
Canada. Operation is subject to the following two conditions:  
1) This device may not cause interference and 2) this device  
must accept any interference, including interference that  
may cause undesired operation of the device.  
(hardwired heaters only) (WSK-21 & WSK-21-W)  
The wall switch wiring can be found in the  
Section “4. Wiring”.  
The wall switch has an operating voltage of 12VDC, do  
not hook up to 120/240VAC. For installations you can  
use 24AWG thermostat wire connected to a standard wall  
switch. It is recommended not to exceed 15 ft of wire from  
heater.  
Note: This equipment has been tested and found to comply  
with the limits for a Class B digital device, pursuant to  
Part 15 of the FCC rules. These limits are designed to  
provide reasonable protection against harmful interference  
in a residential installation. This equipment generates, uses  
and can radiate radio frequency energy, and, if not installed  
and used in accordance with the instructions, may cause  
harmful interference to radio communications. However,  
there is no guarantee that interference will not occur in a  
particular installation.  
With the main power switch (located on the dashboard)  
in the “ON” position, the wall switch can turn the heater  
on and off. The wall switch does not control the other  
switches or controls located on the dashboard. Features of  
the heater (flame motion and heater/blower assembly) will  
remain in their last set position. If you would like to change  
the setting, you will have to access the manual controls  
(located on the heater) to set the desired position.  
The heater must be turned on and off by the wall switch.  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
9
A. Troubleshooting Guide  
Issues  
Possible Causes  
Solutions  
1. Turn the power switch to the “ON” position.  
Heater doesn’t turn on with the main  
switch or remote transmitter.  
1. Power switch is off.  
2. Circuit breaker is tripped  
2. May need to put the heater on a dedicated service or  
reduce the number of appliances on the circuit.  
3. Heater is unplugged from wall outlet.  
4. Loose wiring.  
3. Plug the cord into an outlet.  
4. Check all wiring for loose connections.  
1. Replace the bulbs.  
Heater is on, but no flame or low flame 1. The bulbs are burned out  
intensity.  
2. Loose wiring.  
2. Check all wiring for loose connections.  
1. Check all wiring for loose connections.  
2. Reattach the flame element to the motor.  
Flames are frozen.  
1. Loose wiring.  
2. Flame element is not attached to the  
motor.  
3. Motor is defective.  
3. Replace the motor.  
Excessive noise in the lower portion of 1. Flame element isn’t seated properly.  
1. Reinstall the flame element.  
2. Replace the motor.  
the heater.  
2. Motor is defective.  
Heater/blower assembly doesn’t come 1. Heater/blower assembly switch is off.  
1. Turn the heater switch to the “ON” position.  
on.  
2. Thermostat is set too low.  
2. Move the thermostat knob clockwise until you hear a  
“click”.  
3. Heater/blower assembly is overheated.  
3. The heater/blower assembly is protected by a thermal  
cutout switch. Shut off all heater switches on the  
dashboard including the main power switch. Wait 5  
minutes, then turn the heater on.  
4. Loose wiring.  
4. Check all wiring for loose connections.  
1. Check all wiring for loose connections.  
2. Replace the heater/blower assembly.  
1. Check all wiring for loose connections.  
2. Replace the heater/blower assembly.  
Fan runs but not heat is put out.  
1. Loose wiring.  
2. Bad heating element.  
1. Loose wiring.  
Heater element is on but fan doesn’t  
run.  
2. Fan is defective.  
1. Thermostat is set too high.  
The heater/blower assembly doesn’t  
turn off.  
1. Move the thermostat knob counter-clockwise until you  
hear a “click”.  
Excessive noise in upper portion of the 1. Build up of dirt on the fans.  
1. Clean all fans.  
heater.  
2. Heater fan is defective.  
2. Replace the heater/blower assembly.  
1. Move remote closer to the heater.  
2. Replace the batteries.  
Remote control doesn’t work.  
1. Remote is out of range.  
2. Low batteries.  
Odor.  
The heater may emit a slight, harmless  
odor when first used. This is a normal  
condition caused by initial heating of the  
internal parts and will not occur again.  
18  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance and Service  
10  
A. Cleaning the Firebox and Control Compart-  
ment  
WARNING  
Shock Risk  
Burn Risk  
Cleaning, performing maintenance or moving  
this electric heater without disconnecting  
power and allowing the heater to cool could  
create a shock or burn hazard.  
Keep the firebox, control compartment and heater system  
clean. Clean by brushing and vacuuming at least once a  
year. To access the control compartment, follow the instruc-  
tions for replacing the light bulbs. Follow the heater system  
maintenance instructions to access the heater system. Fail-  
ure to do this may shorten the fan’s life. Always disconnect  
power before performing any cleaning or maintenance.  
Turn controls to “OFF”.  
Remove plug from outlet or turn off the  
circuit breaker to the heater.  
B. Cleaning the Back Acrylic Panel  
The acrylic panel is cleaned in the factory during the as-  
sembly process. During shipment, installation, handling,  
etc., the surface may collect dust particles. These can be  
removed by buffing lightly with a clean dry cloth.  
WARNING  
Burn Risk  
To remove fingerprints or other marks, the acrylic panel can  
be cleaned with a damp cloth using a mild soap and water  
solution. DO NOT USE GLASS CLEANER! IT WILL RUIN  
THE ACRYLIC PANEL! The acrylic panel should be com-  
pletely dried with a lint free cloth or paper towel.  
Accidental burning of the skin could occur.  
Allow at least 15 minutes for the light  
bulbs to cool before touching them.  
C. Replacing the Light Bulbs  
The light bulbs will need to be replaced when the flame and/  
or ember bed is dark on one side. Replace the bulbs with  
75 watt halogen bulbs with mini-candelabra base. Do not  
exceed 75 watts per bulb. Light bulbs can be purchased at  
local hardware, lighting stores, online or by phone. Sylvania  
model 75Q/CL/MC/RP or Satco model S3157 are recom-  
mended.  
Turn off circuit breaker or unplug heater before replacing  
the light bulbs.  
Open the lower grille panel to view the dashboard on the  
heater (the lower grille may need to be removed).  
Remove the four outer screws. See Figure 10.1.  
Pull dashboard towards you to expose the light  
compartment (the light compartment does not need to be  
pulled all of the way out of the heater).  
Remove Screws  
Bulbs  
Carefully remove burned out bulb from light socket. Place  
new bulb in socket. Follow directions on light bulb package  
for handling requirements.  
Slide dashboard back into heater and make sure all wires  
are inside heater.  
Remove Screws  
Figure 10.1 Replacing the Bulbs  
Reinstall the four screws removed earlier.  
Turn on circuit breaker or plug heater back into wall  
outlet.  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D. Heater/Blower Assembly Maintenance  
Turn off the circuit breaker/unplug the heater before  
servicing the heater/blower assembly.  
Allow heater to cool before removing.  
Open the lower grille panel to view the dashboard on the  
heater (the lower grille may need to be removed).  
Remove the four outer screws. See Figure 10.2.  
Pull dashboard towards you to expose the light  
compartment (the light tray does not need to be pulled all  
of the way out of the heater).  
Remove  
Outer  
Reach into the back of the left rear corner of the light tray  
and unplug wire harness from connector. To remove plug,  
squeeze both sides and pull.  
Screws  
Remove the hood by pulling it straight out.  
Remove the upper grille panel/door front by lifting it up  
and out.  
Remove the four outer screws. See Figure 10.2.  
Pull the heater/blower assembly out of heater.  
Slide the heater/blower assembly back into the heater,  
making sure that the wires do not touch the heater/blower  
assembly housing.  
Figure 10.2 Installing Heater/Blower Assembly  
Once the front of the heater/blower assembly is flush with  
heater, reinstall the four screws removed earlier.  
Replace the upper grille panel and hood.  
Plug the wire harness back into the connector in the back  
of the left rear corner of the light tray.  
Slide dashboard back into heater and make sure all wires  
are inside heater.  
Reinstall the four screws removed earlier.  
Turn on the circuit breaker or plug the heater back into  
the wall outlet.  
E. Maintenance Task List  
Inspect  
Maintenance Tasks  
Circulation Compartment 1. Remove any foreign objects.  
2. Verify unobstructed air circulation.  
20  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reference Materials  
11  
A. Heater Dimensions  
16-7/8 in.  
(429 mm)  
30 in.  
(762 mm)  
14 in.  
(356 mm)  
31 in.  
(787 mm)  
36 in.  
(914 mm)  
6-1/2 in.  
(165 mm)  
3-1/8 in.  
(79 mm)  
31-1/8 in.  
(791 mm)  
QV32E-B/QV32EV-B  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. Optional Components  
SIGNAL  
LIGHT  
ON  
ON/OFF  
OFF  
BUTTONS  
12V  
BATTERY  
COMPARTMENT  
WSK-21  
WSK-21-W  
Wall Switch Kit  
FRONT  
BACK  
RCE-QUAD-B  
Remote Control  
Fronts  
QV32E-B Series  
Part #  
Part #  
Description  
Finish  
Description  
Finish  
DF-32RA-HP Remington Avenue  
DF-32RA-BK Remington Avenue  
DF-32TS-HP Town Square  
DF-32TS-BK Town Square  
DF-32SP-HP Sun Prairie  
Hammered Pewter  
Black  
DF-32-CH-HP Chapel Hill  
Hammered Pewter  
Black  
DF-32CH-BK Chapel Hill  
Hammered Pewter  
Black  
DF-32HH-BK Harmony Hill  
Black  
DF-32SPO-BK Sun Prairie Operable Door  
DF-32SPO-HP Sun Prairie Operable Door  
Black  
Hammered Pewter  
Black  
Hammered Pewter  
DF-32SP-BK Sun Prairie  
22  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trim Kits  
PBT-550  
BKT-550  
Cabinet Trim  
PB = Polished Brass Finish  
BK = Black Finish  
Surrounds  
VTS-550  
VTS-550-BK  
Flush Surrounds  
(chase installations only  
Quick Tile Black and Brass Surrounds  
QV32E-B Series  
ROF44SB_*  
MVF44SB_*  
PLF44SB_*  
no suffix = Polished Brass Finish  
BK = Black Finish  
* O = Unstained Oak  
* P = Primed  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C. Service Parts  
Service Parts  
VILLAGE COLLECTION  
Beginning Manufacturing Date: Apr 2005  
Ending Manufacturing Date: Active  
Exploded Parts Diagram  
QV32E-B Series  
1
2
3
4
16  
15  
5
11  
11 - Light Tray Assembly  
9
13  
12  
14  
24  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service Parts  
Service Parts List  
QV32E-B Series  
VILLAGE COLLECTION  
Beginning Manufacturing Date: Apr 20905  
Ending Manufacturing Date: Active  
# Description of Part  
Reflective Flame Decal  
11 Light Tray Assembly  
13 Halogen Light  
14 Motor w/Vinyl Cover Assy  
12 Flame Element Kit  
QV32E-B Series Qty.  
4021-190  
4030-020  
33961  
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4030-883  
4030-200  
4030-050  
4030-716  
4030-782  
4030-043  
4030-049  
4030-055  
4030-608  
4030-219  
4030-840  
4038-810  
4030-218  
4030-018  
4030-831  
4030-832  
9
3
Screen & Rod Assy  
Fixed Ember Bed  
Installation Manual  
120VAC Heater Assy  
240VAC Heater Assy  
Electric Log Assy  
1
1
5
4
QV32E Grate Assembly  
Rock Retainer  
16 Lenticular Lens  
15 Acrylic Panel  
2
Upper Glass Retainer  
Power Cord  
Refractory Side LH  
Refractory Side RH  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This page intentionally left blank.  
26  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D. Limited Warranty  
Hearth & Home Technologies Inc.  
1445 North Highway  
Colville, WA 99114-2124  
WARRANTY  
Hearth & Home Technologies Inc. (HHT) Electric Fireplaces are tested and inspected prior to shipment and  
are guaranteed from defect to the purchaser of each new product. Any part which proves to be defective in  
material or workmanship under normal use within one year will be repaired or replaced without charge.* The  
Company will not be responsible for any expense incurred for installation, removal from service, or transpor-  
tation costs. Any such defect should be brought to the attention of the Dealer where the product was pur-  
chased and is authorized to repair or replace within the terms of this warranty.  
The Company’s only obligation under this warranty will be at its sole option to repair or replace any part prov-  
ing defective or to refund the purchase price thereof.  
The owner/user assumes all other risks, if any, including the risk of any direct, indirect or consequential loss  
or damage arising out of the use of or inability to use the product.  
The warranty will not apply if, in the sole judgement of the Company, damage or failure has resulted from ac-  
cident, alteration, misuse, abuse, incorrect installation, or operation on an incorrect power source.  
The foregoing is in lieu of all other warranties expressed, implied, or statutory, and the Company neither as-  
sumes, nor authorizes any person to assume for it any other obligation, or liability in connection with said  
product.  
*Light bulbs are not covered in the warranty.  
How to Obtain Service  
To obtain service under this warranty you must:  
1. Send written notice of the claimed condition to Quadra-Fire Technical Service Department, Hearth & Home  
Technologies Inc., 1445 North Hwy., Colville, WA 99114-2124.  
2. Provide proof of purchase, model number, serial number, and manufacturing date code to HHT.  
3. Provide HHT reasonable opportunity to investigate the claim, including reasonable opportunity to inspect the  
Appliance prior to any repair or replacement work and before the Appliance or any component of the Appli-  
ance has been removed from the place of original installation.  
4. Obtain HHT’s consent to any warranty work before the work is done.  
ADDITIONAL INFORMATION: If you would like information on current Quadra-Fire products or want to locate a  
dealer in your area, call 1-800-926-4356.  
©2003 Quadra-Fire® is a Registered Trademark of Hearth & Home Technologies Inc.  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E. Contact Information  
Hearth & Home Technologies Inc.  
1445 North Highway  
Colville, WA 99114-2124  
Please contact your Quadra-Fire dealer with any questions or concerns. For  
the number of your nearest Quadra-Fire dealer, please call 1-800-926-4356.  
– NOTES –  
CAUTION  
DO NOT DISCARD THIS MANUAL  
Read, understand  
and follow these  
instructions for safe  
installation and  
operation.  
Leave this manual with  
party responsible for  
use and operation.  
Important operating  
and maintenance  
instructions included.  
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876,  
4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983,  
5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237,  
5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079,  
6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940,  
6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039,  
6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403,  
1418504 or other U.S. and foreign patents pending.  
28  
Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Quantum Wheelchair INFMANU4169 User Guide
Revolabs Mouse 8000 User Guide
Roberts Radio Portable CD Player SC9911 User Guide
Rose electronic Switch ULTRAMATRIX 2xE User Guide
Rotel CD Player RCD 970BX User Guide
Samsung Car Video System 205BW User Guide
Samsung Microwave Oven SMH8165STE User Guide
Samsung Refrigerator SRS610HDSS User Guide
Sanyo CRT Television ce32ld08 b User Guide
Sears Refrigerator 10062603 User Guide