Premier Mounts Indoor Furnishings PP FCMA QL User Manual

INSTALLATION INSTRUCTIONS  
PP-FCMA-QL  
Suspended Ceiling Tile Adapter  
EUROPE  
Swallow House,  
Shilton Industrial Estate,  
Shilton, Coventry, England CV79JY  
Phone: +44 (0) 2476 614700  
Fax: +44 (0) 2476 614710  
NORTH AMERICA  
3130 East Miraloma Avenue  
Anaheim, CA 92806 USA  
USA and Canada –  
Phone: 800-368-9700  
Fax: 800-832-4888  
Other Locations – Phone: (001)-714-632-7100; Fax: (001)-714-632-1044  
©Premier Mounts 2008  
9533-010-001-01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PP-FCMA-QL  
Parts List  
Thisceilingadapterisshippedwithallproperinstallationhardwareandcomponents.Makesurethatnoneoftheseparts  
are missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop the  
installation and contact Premier Mounts (800-368-9700).  
Quick Locks (Qty 4)  
PP-FCMA-QL(Qty 1)  
Braided Cable (Qty 4 Strands)  
¼” x 3” Eye Lag Screws (Qty 4)  
Pipe Clamp (Qty 4)  
M8 x 20mm Phillips Head Screws (Qty 4)  
Rubber Caps (Qty 4)  
1/4-20 KEP Nut (Qty 4)  
M8 Flat Washers (Qty 4)  
M5 x 16mm Phillips Head Screw  
(Qty 1)  
EMT Conduit Pipe (Optional - Qty 2)  
Commercially Available  
24” T-Bar Frame (Qty 1)  
Commercially Available  
¼” x 3” Concrete Anchors (Qty 4)  
Installation Tools  
Phillips Head Screwdriver  
Wire Cutters  
Ladder  
Installation Instructions  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PP-FCMA-QL  
Ceiling Tile Removal  
Read all cautions and warnings before continuing.  
Observe the room and the ceiling; find the proper location for the PP-FCMA-QL placement and lightly mark  
the bottom of the tile.  
Step 1. Carefully remove the 24” x 24” or, depending on your ceiling configuration, the 24” x 48” suspended ceiling tiles.  
Page 4  
Installation Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PP-FCMA-QL  
Ceiling Anchoring  
THE PP-FCMA-QL MUST SECURED USING THE SUPPLIED QUICK LOCKS AND  
BRAIDED CABLES.  
Truss  
Concrete  
Wood  
Truss  
Concrete  
Wood Joist  
Eye Lag Hole  
Loop  
Eye Lag Hole  
Loop  
Braided Cable  
Braided Cable  
Concrete  
Truss ceiling  
Wood Joist  
Step 1. Determine the mounting  
location.  
Step 2. Use a 1/4” masonry drill bit  
to pre-drill the mounting  
holes.  
Step 3. Place the concrete anchor  
into the pre-drilled hole and  
gently tap into place using a  
rubber mallet or hammer.  
Step 1. Loop the braided cable  
around the truss.  
Step 2. Run the open end through  
the loop.  
Step 3. Pull the open end down until  
the braided cable tightens  
around the truss.  
Step 1. Secure the four (4) ¼” eye  
lag screws to the wood joist  
in the ceiling.  
Step 2. Make sure eye lag screws  
are properly secured to the  
joist before securing the wire  
to the cable locks on the  
plate.  
Step 3. Run the open end through  
the hole in the eye lag  
screw.  
Step 4. Run the open end through  
the loop.  
Step 5. Pull the open end down until  
the braided cable tightens  
around the eye lag screw.  
Installation Instructions  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PP-FCMA-QL  
Eye Lag Screw  
Permanent Mounting  
Structure  
Eye Lag Screw  
Braided Cable  
T-bar Frame  
Ceiling Tile  
Step 1. Attach the braided cable, using the directions on page 5, in the appropriate manner for your mounting configuration.  
Step 2. Let the four (4) strands of braided cable hang down off to one side of the opening in the ceiling.  
PP-FCMA-QL Installation  
Mounting Studs on  
the Bottom  
Dual Knock Outs  
24”x24” Ceiling Tile  
Ceiling  
24”x48” Ceiling Tile  
24” ‘T’ Bar  
(Commercially  
Available)  
The dual knock out plates for the electrical box  
must be removed prior to installation.  
Step 1. Install the PP-FCMA-QL plate securely onto the T-bar framework with the mounting studs face down (according to your  
installation configuration).  
In the event that you are using the PP-FCMA-QL in an opening that is 24” x 48”, a 24” piece of T-bar (commercially avail-  
able) must be used to support the mount and ceiling tile. The T-bar (commercially available) will run from side to side  
and help support the PP-FCMA-QL and 24” x 24” replacement ceiling tile (commercially available).  
Page 6  
Installation Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PP-FCMA-QL  
Attaching the Pipe Clamps  
1/4” KEP Nut  
Pipe Clamp  
PP-FCMA-QL  
Step Bolt  
Ceiling Tile  
Step 1. Locate the pre-installed step bolts that are on the PP-FCMA-QL.  
Step 2. Remove the four (4) black rubber caps from the step bolts.  
Step 3. Lower the pipe clamp onto the step bolt.  
Step 4. Secure the pipe clamp to the PP-FCMA-QL using a 1/4” KEP nut (see above).  
Step 5. Tighten all hardware with a wrench (commercially available).  
Step 6. Re-attach the four (4) black rubber caps onto the step bolts.  
Step 7. Repeat steps 1 through 3 for the remaining pipe clamp installation.  
Attaching the EMT Conduit Pipe (Optional)  
M8 x 20mm Screw  
and M8 Nut  
Pipe  
T-Bar  
PP-FCMA-QL  
Pipe Clamp  
Ceiling  
Step 1. For added security, slide two (2) 3/4” EMT conduit pipe (commercially available) through the pipe clamps.  
Step 2. Once the EMT conduit pipe (commercially available) is installed, use a screwdriver to tighten the four (4) M8 x 20mm  
Phillips head screws and four (4) M8 nuts.  
The EMT conduit pipe must cross over two sections of the T-bar framework on both sides of the pipe clamps.  
Installation Instructions  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PP-FCMA-QL  
Quick Lock Installation  
Re-check all hardware and installation for proper tightness and security and replace the tile.  
Feed braided cable into the cable lock (see directional  
input arrows). To release the braided cable, slide the  
release pin to disengage the braided cable.  
Cable Output  
Cable Input  
Directional Input Arrows  
Release Pin  
Directional Input Arrows  
Braided  
Braided  
Braided  
Braided  
Cable  
Cable  
Cable  
Cable  
6” Excess  
Directional Input  
Arrows  
Directional Input  
Arrows  
Directional Input  
Arrows  
Release Pin  
Release Pin  
Release Pin  
Release Pin  
Mounting Hole  
Mounting Hole  
Mounting Hole  
Page 8  
Installation Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PP-FCMA-QL  
Braided  
Cable  
Cable  
Lock  
EMT  
Conduit  
Ceiling  
Tile  
T-Bar  
Frame  
Step 1. Once the braided cables have been attached to the upper mounting structure (wood joist, concrete or ceiling truss), it is now  
time to attach the braided cable to the PP-FCMA-QL.  
Step 2. Thread each braided cable through the Quick Lock (see previous page).  
Step 3. Loop the braided cables through the space between the EMT conduit pipe and the top of the pipe clamp (see previous page).  
Step 4. When adjusting the tension of the weight-bearing side of the Quick Lock, the cable must be pulled through the Quick Lock until  
the desired tension is attained. Once attained, pull the braided cable through the other side of the Quick Lock  
(see previous page).  
Step 5. Once the tension has been adjusted, be sure that there is at least 6” of excess braided cable on the non-weight bearing side of the  
Quick Lock.  
Step 6. Use cable cutters to remove any remaining braided cable (optional).  
Ceiling  
Tile  
If you chose to use the optional EMT conduit pipe, the ceiling tiles where the EMT conduit pipe crosses over must be  
installed prior to installing the EMT conduit pipe.  
Step 7. Reinstall the ceiling tile.  
Installation Instructions  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PP-FCMA-QL  
Electrical Box Installation  
Electrical installation should be done in accordance to local codes and regulations.  
Step 1. Cut the tile where the electrical base box is going to be secured.  
Step 2. Using (commercially available) hardware depending on electrical installation environment, install the electrical box and secure  
it to the plate.  
Step 3. Make all electrical connections at this time.  
Electrical Box  
Electrical Box  
Cut-out  
PP-FCMA-QLAdjustments  
Ceiling Tile  
PP-FCMA-QL  
M8 Flat  
Washer  
M8 x 20mm  
Phillips Head  
Screw  
Step 1. Loosen the M8 x 20mm screws and M8 flat washers. This will allow you to slide the base box laterally.  
Please refer to the purchased base box for further operating instructions.  
Page 10  
Installation Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PP-FCMA-QL  
Securing Pipe to the PP-FCMA-QL  
Step 1. Secure the 1½” (NPT) pipe to the ceiling plate and tighten by using one (1) M5 x 16 Phillips head screw (supplied)  
to the plate.  
The M5 x 16 Phillip head screw must be used to stabilize the 1½” (NPT) pipe.  
M5 x 16mm  
Screw  
1-1/2” Pipe  
Opening  
PP-FCMA-QL  
Technical Specications  
All measurements are in inches (mm).  
Installation Instructions  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PP-FCMA-QL  
Warranty  
PREMIER MOUNTS  
LIMITED LIFETIME WARRANTY  
What and Who is Covered by this Limited Warranty and for How Long  
Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of  
the original owner of this product. The limited warranty is valid only for the original purchaser of the product.  
What Premier Mounts Will Do  
At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that is  
defective. If Premier Mounts chooses to replace a defective product or part, a replacement product or part will  
be shipped to you at no charge, but you must pay any labor costs.  
What is Not Covered; Limitations  
PREMIER MOUNTS DISCLAIMS ANY LIABILITY FOR DAMAGE TO MOUNTS, ADAPTERS, DIS-  
PLAYS, PROJECTORS, OTHER PROPERTY, OR PERSONAL INJURY RESULTING, IN WHOLE OR IN  
PART, FROM IMPROPER INSTALLATION, MODIFICATION, USE OR MISUSE OF ITS PRODUCTS.  
PREMIER MOUNTS DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING  
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. PREMIER  
MOUNTS IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUD-  
ING BUT NOT LIMITED TO, INABILITY TO USE ITS PRODUCTS OR LABOR COSTS FOR REMOV-  
ING AND REPLACING DEFECTIVE PRODUCTS OR PARTS. SOME STATES DO NOT ALLOW THE  
EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE  
LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.  
What Customers Must Do for Limited Warranty Service  
If you discover a problem that you think may be covered by the warranty you MUST REPORT it in writing to  
the address below within thirty (30) days. Proof of purchase (an original sales receipt) from the original con-  
sumer purchaser must accompany all warranty claims. Warranty claims must also include a description of the  
problem, the purchaser’s name, address, and telephone number. General inquiries can be addressed to Premier  
Mounts Customer Service at 1-800-368-9700. Warranty claims will not be accepted over the phone or by fax.  
Premier Mounts  
Attn: Warranty Claim  
3130 E. Miraloma Avenue  
Anaheim, CA 92806  
How State Law Applies  
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER  
RIGHTS WHICH VARY FROM STATE TO STATE.  
Page 12  
Installation Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Pelco VCR TLR2168S User Manual
Philips Headphones SHN2500 User Manual
Philips Satellite TV System SLV5405 User Manual
Philips TV Cables SWA2426W User Manual
Philips Work Light 134635 User Manual
Pioneer Projector Accessories RMF V4011R User Manual
Pitco Frialator Fryer SG18S User Manual
Polaroid Digital Camera SX70 User Manual
Polycom IP Phone HDX 9001 User Manual
Proxim Network Router CPN 63708 User Manual