Siemens: HiPath Wireless System with 2610, 2620 APs  
Introduction  
SpectraLink's Voice Interoperability for Enterprise Wireless (VIEW)  
Certification Program is designed to ensure interoperability and high  
performance between SpectraLink 8000 Wireless Telephones and  
WLAN infrastructure products. The products listed below have been  
thoroughly tested in SpectraLink’s lab and have passed VIEW  
Certification. This document details how to configure Siemens HiPath  
C10, C100, C1000 Wireless Controllers and 2610 & 2620 access points  
(APs) with SpectraLink 8000 Wireless Telephones.  
Certified Product Summary  
Manufacturer:  
Siemens HiPath Wireless:  
Approved products:  
Wireless Controllers  
Access Points  
C10 †  
C100  
C1000  
2610 †  
2620 †  
RF technology:  
802.11b/g  
Radio:  
2.4 – 2.484 GHz  
WPA-PSK, WPA2-PSK  
3.1.4.03.03  
Security:  
AP firmware version tested:  
SpectraLink handset models tested:  
SpectraLink handset software tested:  
SpectraLink radio mode:  
Maximum telephone calls per AP:  
Recommended network topology:  
e340/h340/i640  
89.124  
8020/8030  
122.010 or greater  
802.11b  
802.11b  
10  
10  
Switched Ethernet (recommended)  
Denotes products directly used in VIEW Certification testing  
Known Limitations  
Beacons are sent from the AP inconsistently; therefore you may  
see decreased battery life on the handsets.  
A hex-key is not supported with both WPA-PSK and WPA2-PSK.  
You must use a passphrase for each.  
Because the Controller configures a virtual subnet, broadcast data  
cannot be sent to the handsets.  
PN: 1725-36071-001_C.doc  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Guide  
Network Topology  
The following topology was tested during VIEW Certification. It is  
important to note that these do not necessarily represent all "certified"  
configurations. The access points were powered through a mid-span  
POE adaptor.  
PN: 1725-36071-001_C.doc  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Siemens: HiPath Wireless System with 2610, 2620 APs  
Installing Software & Configuration  
1. If software upgrades are required, contact Siemens Customer  
Support for the latest version of software and instructions.  
2. The current version of software installed can be found by opening  
a telnet session of the AP and typing the command version, or by  
looking at the configuration GUI under Wireless APs and selecting  
the general tab for the AP in the field s/w version.  
3. If you encounter difficulties or have questions regarding the  
configuration process, please contact your Siemens representative  
or visit the web site  
PN: 1725-36071-001_C.doc  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Guide  
Initial Setup  
1. The following instructions are for configuring a wireless controller  
and a number of access points with no prior configuration.  
2. All of the initial setup is done via a web interface. Connect a  
‘Cross-Over’ Ethernet cable directly from the Management Port of  
the controller to a PC’s Ethernet port.  
3. Log onto the controller by opening a web browser and connect to  
default password is abc123.  
4. Do this step only if it is necessary to reset the controller back to its  
factory default configuration:  
a. Click the Wireless Controller button to open the Wireless Controller  
Configuration screen.  
b. In the navigation pane, click System Maintenance.  
c. Click the Reset database to factory default and reboot button.  
d. Click the Apply button.  
This will reset the database and cause the controller to reboot.  
It will take three to four minutes before the controller is  
finished.  
PN: 1725-36071-001_C.doc  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Siemens: HiPath Wireless System with 2610, 2620 APs  
Controller Setup  
The setup steps described below refer to the network topology  
diagram shown in this document. Make sure all the access points are  
disconnected from the system if configuring the system for the first  
time.  
Assigning an IP address to a wireless controller  
1. Log onto the controller by opening a web browser and connect to  
default password is abc123.  
2. Click the Wireless Controller button.  
3. In the navigation pane, click IP Addresses.  
4. Change the value of esa0 to 192.168.110.10 for the IP Address, and  
to 255.255.255.0 for the Subnet mask.  
5. Select the Mgmt and SLP check boxes for this port only (thus  
turning it on). Leave these unchecked (off) for the other ports.  
6. For Function, select Host Port if static routing is used. Otherwise,  
select Dynamic Port if Open Shortest Path First (OSPF) is being used  
for routing and routing advertisements.  
7. Enter esa0 for Multicast Support. Refer to the screen shot shown  
below.  
8. Click the Save button.  
This is for topologies where the SpectraLink 8000 Telephony  
Gateway(s) and SVP Servers are located adjacent to the esa0 port,  
as was done in this VIEW Certification test. In topologies where the  
setup is different, this multicast setting should be configured to  
whichever port the SpectraLink servers are adjacent to. This setting  
permits proper wired replication of multicast data from the wireless  
subnet.  
PN: 1725-36071-001_C.doc  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Guide  
PN: 1725-36071-001_C.doc  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Siemens: HiPath Wireless System with 2610, 2620 APs  
Assigning routing protocols to a wireless controller  
1. In the Wireless Controller screen, click Routing Protocols in the  
navigation pane.  
2. Enter 0.0.0.0 for the Destination Address and 0.0.0.0 for the Subnet  
Mask. Add the appropriate address for the Gateway.  
3. Click the Save button.  
If dynamic routing (OSPF) is being used, then the default route  
should be set automatically. However, it is always recommended  
that you assign a temporary static route in dynamic environments to  
allow the device to operate immediately without having to wait for  
the initial updates. Be sure to clear the check box for Override  
dynamic routes. This will allow dynamic routes to be the default once  
they arrive.  
PN: 1725-36071-001_C.doc  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Guide  
AP registration  
1. Click the Wireless APs button.  
2. Click AP registration in the navigation pane.  
3. Enter all information for your APs (see screen shot below). Make  
sure the setting for Security Mode is selected to Allow all Wireless APs  
to Connect.  
4. Click the Save button.  
This setting allows new APs to be added to the system  
automatically. Once the addition of APs is complete, it is  
recommended to switch this setting back to Allow only approved  
Wireless APs to connect.  
PN: 1725-36071-001_C.doc  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Siemens: HiPath Wireless System with 2610, 2620 APs  
AP maintenance  
1. In the Wireless APs screen, click AP Maintenance in the navigation  
pane.  
2. Select the proper image file in the AP Images box and click the  
Set as default button.  
3. Under Upgrade Behavior select the Upgrade when AP connects using  
settings from Controlled Upgrade option.  
4. Select the Do not upgrade AP images if current image version = upgrade  
version check box.  
5. Under Downgrade Behavior, select the Automatically downgrade AP to  
default image if AP is at later release number (major/minor rev) check  
box.  
6. Click the Save button.  
PN: 1725-36071-001_C.doc  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Guide  
Setting up SSID, Security and QOS  
1. Click the VNS Configuration button.  
2. Click the Topology tab.  
3. Assign a subnet for clients for a specific SSID.  
4. Under DHCP Settings:  
a. Enter the appropriate address for the Gateway  
b. For Mask enter 255.255.255.0.  
c. The address range should default to 192.168.121.2 –  
192.168.121.254. Change this if you want a limited range of  
addresses assigned to this subnet.  
d. No DNS Servers or WINS is required.  
5. Set the Timeout Idle: pre and post to 2.  
6. Under Next Hop Routing, set the OSPF Route Cost to 50000.  
7. Enter an SSID name.  
8. Under Wireless APs, select the b/g check box for each AP.  
9. Click the Save button.  
PN: 1725-36071-001_C.doc  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Siemens: HiPath Wireless System with 2610, 2620 APs  
PN: 1725-36071-001_C.doc  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Guide  
Filtering  
1. In the VNS Configuration screen, click the Filtering tab.  
2. Select Default from the Filter ID drop-down list.  
a. Select all three options - In, Out and Allow.  
b. Leave the IP:Port as *.*.*.*.  
3. Select Non-Authenticated in the Filter ID drop-down list.  
a. Select all 3 options - In, Out and Allow.  
b. Leave the IP:Port as *.*.*.*.  
4. Click the Save button.  
A more secure setup for this topology might be:  
Allow 192.168.121.* UDP  
Allow 192.168.110.* UDP  
Allow 192.168.123.* UDP  
Disallow*.*.*.* N/A T  
PN: 1725-36071-001_C.doc  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Siemens: HiPath Wireless System with 2610, 2620 APs  
Multicast configuration  
1. In the VNS Configuration screen, click the Multicast tab.  
2. Select the Enable Multicast Support check box.  
3. From the Defined groups drop-down list, select or enter  
Spectralink SVP (224.0.1.116) and click the Add button.  
4. Enable Wireless Replication for the multicast selection by selecting  
the check box beside the entry.  
5. Click the Save button.  
PN: 1725-36071-001_C.doc  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Guide  
Security  
1. In the VNS Configuration screen, click the Privacy tab.  
2. For WPA2 AES-CCKM, click the WPA-PSK option, clear the  
WPA v.1 check box, then select the WPA v.2 check box.  
3. For WPA TKIP, click the WPA-PSK option, clear the WPA v.2 check  
box, then select the WPA v.1 check box.  
4. Enter the appropriate pass phrase in the Pre-shared key field.  
5. Click the Save button.  
There is no hex key available at this time.  
PN: 1725-36071-001_C.doc  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Siemens: HiPath Wireless System with 2610, 2620 APs  
Quality of service  
1. In the VNS Configuration screen, click the Policy tab.  
2. From the Quality of Service drop-down list, select Voice VNS w/o  
WMM; this is required for SpectraLink phones.  
3. Click the Save button.  
Setting up other SSIDs  
1. Repeat the above steps, starting at step 1.  
2. Create a new SSID and DHCP pool as before. Each SSID has its  
own sub-net.  
3. Use the same filtering settings as before.  
4. Set up privacy as required.  
5. If creating a sub-net for data, select Best Effort in the Policy page.  
Make sure the proper SSID is selected on each page as it is being  
configured.  
PN: 1725-36071-001_C.doc  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Guide  
Connecting access points to the controller  
1. Click the Reports button.  
2. Make sure the controller is configured to accept new APs (this is  
selected by default).  
3. Physically connect the access points to the system one at a time.  
Once an AP is connected to the system, it will show up in the  
Active Wireless APs screen of the Reports menu.  
4. Press F5 to refresh the screen.  
PN: 1725-36071-001_C.doc  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Siemens: HiPath Wireless System with 2610, 2620 APs  
Wireless APs address assignment  
1. After all the APs have been connected and discovered by the  
controller, click Wireless APs tab.  
2. Click the Static Configuration tab.  
3. Select an AP to configure. The AP’s name will default to their  
MAC address.  
4. Under IP Address Assignment click either the Use DHCP or the Static  
Values option. If selecting Static Values, assign the proper values.  
5. Under Wireless Controller Search List add the IP address of the  
controller port.  
6. Repeat steps 4 and 5 for each access point.  
7. Click the Save button.  
PN: 1725-36071-001_C.doc  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Guide  
For each AP, follow the steps in the following sections:  
AP properties  
1. In the Wireless APs screen, click the AP Properties tab. Select an AP to  
configure. Here you can assign a meaningful name to each AP.  
2. Enable Telnet Access. This is useful for troubleshooting the setup  
and configuring security settings.  
802.11b/g settings  
1. In the Wireless APs screen, select the 802.11 b/g tab.  
2. Select an AP to configure.  
3. Under Base Settings:  
a. Set the DTIM Period to 3.  
b. Set the Beacon Period to 100.  
c. Set the RTS/CTS Threshold to 2346.  
d. Set the Frag. Threshold to 2346.  
PN: 1725-36071-001_C.doc  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Siemens: HiPath Wireless System with 2610, 2620 APs  
4. For Enable Radios, select the 802.11b check box.  
5. Under Radio Settings:  
a. Select the appropriate Channel and Tx Power Level.  
(Note: DRM values will override this setting, if enabled).  
b. Set the Diversity to Best.  
c. Set the Min Basic Rate to 1 Mbps.  
d. Set the Max Basic Rate to 11Mbps.  
e. Set the Max Operational Rate to 11Mbps.  
f. Set the Preamble to Short (note that the value Long works as  
well).  
6. Click the Save button.  
PN: 1725-36071-001_C.doc  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Guide  
Enable the radio  
1. Click the VNS Configuration button.  
2. Click the Topology tab.  
3. Enable each AP’s b/g radio for each SSID.  
4. Set No. of Retries for Voice VO to adaptive (multi-rate) and No. of Retries  
for Turbo Voice TVO to 2.  
5. Click the Save button.  
After the controller and access points are set up, the Management  
port is no longer required. The Controller can now be managed  
through the Host Port, or the esa0 port in this configuration. Open a  
PN: 1725-36071-001_C.doc  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Philips Baby Monitor SCD588 54 User Manual
Philips Cassette Player AQ6591 01Z User Manual
Philips Indoor Furnishings 22FDF4023 User Manual
Philips Telephone Accessories SWL4160 User Manual
Pioneer Blu ray Player DVR810H User Manual
Polaris Offroad Vehicle X2 500 EFI User Manual
Porter Cable Air Compressor CPF6025VP User Manual
Powerware Power Supply 650825 kVA User Manual
Prince Castle Pasta Maker 630 ROM4 User Manual
PVI Industries Water Heater PV500 47C User Manual