Planet Technology Switch GSW 2416SF User Manual

24-Port 10/100/1000Mbps with 16-Port SFP  
Web Smart Ethernet Switch  
GSW-2416SF  
User’s Manual  
- 1 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
EM-GSW2416SFv1  
- 3 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. INTRODUCTION  
1.1 Checklist  
Check the contents of your package for following parts:  
z
z
z
z
z
z
z
GSW-2416SF x1  
User's manual CD x1  
Quick installation guide x1  
Power cord x 1  
RS232 cable x1  
Rubber feet x 4  
Two rack-mounting brackets with attachment screws x1  
If any of these pieces are missing or damaged, please contact your dealer immediately, if possible, retain the carton  
including the original packing material, and use them against to repack the product in case there is a need to return it to  
us for repair.  
1.2 About the Switch  
The PLANET GSW-2416SF is a 24-Port 10/100/1000Mbps Web Smart non-blocking wire-speed performance Ethernet  
Switch. With a 48Gbps internal switching fabric, the Switch can handle extremely large amounts of data in a secure  
topology linking to a backbone or high capacity servers. The GSW-2416SF could recognize up to 8K MAC Address table  
and provides 400KB on-chip frame buffer. They offer wire-speed packet transfer performance without risk of packet loss.  
With high data throughput, the GSW-2416SF provides the most convenient for user to upgrade their network to Gigabit  
environment.  
All RJ-45 copper interfaces support 10/100/1000Mbps Auto-Negotiation for optimal speed detection through RJ-45  
Category 6, 5 or 5e cables. Also, all the ports support Auto-MDI/MDI-X that can automatically detect the type of  
connection to any Ethernet device without requiring special straight or crossover cables. 24-Port TP by default and  
together with 16-SFP (Small Form-factor Pluggable), shared with port#9 to port #24, make the switch be a 16-Port  
Gigabit Fiber Switch with mini GBIC fiber-optic module installed that shall provide long distance fiber connectivity.  
The GSW-2416SF provides Smart management functions through the Web management interface. Functions such as  
per port speed, duplex, IEEE 802.3x flow-control settings and 802.1p QoS settings, Trunking and Port-Base VLAN, all  
can be found in the friendly user interface of your web browser. These features provide a cost-effective way to manage  
the devices from Internet whenever you are at work or at home.  
1.3 Features  
Complies with IEEE 802.3, 10Base-T, IEEE 802.3u, 100Base-TX and IEEE 802.3ab, 1000Base-T, IEEE 802.3z,  
1000Base-SX/LX Ethernet standard  
24-Port 10/100/1000Mbps Ethernet ports  
16-Port SFP (Small Form-factor Pluggable) for 3.3V mini GBIC module, shared with port#9 to #24  
Features Store-and-Forward mode with wire-speed filtering and forwarding rates  
Hardware based 10/100Mbps, half/full duplex and 1000Mbps full duplex mode, flow control and auto-negotiation  
IEEE 802.3x flow control for full duplex operation and backpressure for half duplex operation  
Integrated address look-up engine, support 8K absolute MAC addresses  
Remote Web management interface  
9K Jumbo frame support  
Port-based VLAN, Port Trunk, QoS support  
Automatic address learning and address aging  
Supports Auto-MDI/MDI-X function  
EM-GSW2416SFv1  
- 4 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Support CSMA/CD protocol  
100~240VAC, 50~60Hz universal Power input  
FCC, CE class A compliant  
1.4 Specification  
Model  
GSW-2416SF  
10/100/1000Base-T Ports  
24 port RJ-45  
10/100/1000Mbps, Auto Negotiation, Auto-MDI/MDI-X  
16 port 3.3VC mini-GBIC SFP  
1000Mbps full-duplex; shared with port#9 to ort 24  
One power,  
SFP Ports  
LED Display  
1-24 port RJ-45, LNK/ACT,  
9-16 port SFP (mini-GBIC),LNK/ACT  
DB-9 RS-232  
Console  
Switch architecture  
MAC address  
Switch fabric  
Throughput  
Store and forward  
8K MAC address table with Auto learning function  
48Gbps  
35.7Mpps  
Flow Control  
Back pressure for half duplex,  
IEEE 802.3x Pause Frame for full duplex  
Up to 9KB  
Jumbo Frame  
Management  
Console / web management interfaces  
IEEE 802.1p Port priority  
Port Trunk  
Allow to assign low and high priority on each port  
Three trunk groups with up to 4-port per trunk  
VLAN  
Up to 24 port-based VLAN  
Management VLAN  
Power  
Yes  
AC 100~240V, 50/60Hz,  
Power consumption  
Temperature  
Humidity  
Dimension (W x D x H)  
EMI  
Max. 130 watts, 443 BTU/hr  
Operating: 0~50 degree C, Storage -40~70 degree C  
Operating:10% to 90%, Storage: 5% to 95% (Non-condensing)  
440 x 200 x 44 mm (1U height)  
FCC Part 15 Class A, CE  
Standard Compliance  
IEEE 802.3 (Ethernet)  
IEEE 802.3u (Fast Ethernet)  
IEEE 802.3ab(Gigabit Ethernet)  
IEEE 802.3z (Gigabit Ethernet, 1000Base-SX/LX)  
IEEE 802.3x (Flow control)  
IEEE 802.1p QoS  
EM-GSW2416SFv1  
- 5 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2. HARDWARE DESCRIPTION  
This product provides both Copper and Fiber connecter at same switch – 24 Ports TP and 16 Ports SFP (shared with Port  
#9 to 24), and automatically distinguishes the speed of incoming connection.  
This section describes the hardware features of GSW-2416SF. For easier management and control of the Switch,  
familiarize yourself with its display indicators, and ports. Front panel illustrations in this chapter display the unit LED  
indicators. Before connecting any network device to the GSW-2416SF, read this chapter carefully.  
2.1 Front Panel  
The Front Panel of the GSW-2416SF Web Smart Ethernet Switch consists of 24x Auto-Sensing 10/100/1000Mbps  
Ethernet RJ-45 Ports and 16x SFP(Small Form-factor Pluggable) Ports. The LED Indicators are also located on the front  
panel of the GSW-2416SF. And one console port at Front panel for switch management.  
Figure 2-1: GSW-2416SF Switch front panel  
2.1.1 LED indicators  
System  
LED  
Color  
Function  
PWR  
Green Lights to indicate that the Switch has power.  
Per 10/100/1000Mbps port  
LED  
Color  
Function  
Lights to indicate that the Switch is successfully connecting to the network at  
1000Mbps.  
1000  
Green  
LNK/ACT  
Blinks to indicate the Switch is receiving or sending data.  
Lights to indicate that the Switch is successfully connecting to the network at  
100Mbps.  
100  
Amber  
LNK/ACT  
Blinks to indicate the Switch is receiving or sending data.  
Per SFP Interface  
LED  
Color  
Function  
Lights to indicate that the Switch is successfully connecting to the network at  
1000Mbps through SFP interface.  
SFP  
Green  
LNK/ACT  
Blinks to indicate the Switch is receiving or sending data.  
2.2 Rear Panel  
The rear panel of the GSW-2416SF indicates an AC inlet power socket, which accepts input power from 100 to 240V AC,  
50-60Hz, and 1A max. And one I/O power switch at rear panel for power management.  
100~240V  
AC  
ON  
OFF  
50/60H  
POWER  
z
Figure 2-2: GSW-2416SF Switch rear panel  
EM-GSW2416SFv1  
- 6 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Power Notice:  
1. The device is a power-required device, it means, it will not work till it is powered. If your networks should active all the  
time, please consider using UPS (Uninterrupted Power Supply) for your device. It will prevent you from network data  
loss or network downtime.  
2. In some area, installing a surge suppression device may also help to protect your GSW-2416SF from being damaged by  
unregulated surge or current to the GSW-2416SF.  
2.3 Hardware Installation  
This part describes how to install your Web Smart Ethernet Switch and make connections to the Switch. Please read  
the following topics and perform the procedures in the order being presented. To install your Switch on a desktop or  
shelf, simply completed the following steps.  
2.3.1 Desktop Installation  
To install a Switch on a desktop or shelf, simply completed the following steps:  
Step 1: Attached the rubber feet to the recessed areas on the bottom of the Switch.  
Step 2: Place the Switch on a desktop or shelf near an AC power source.  
Step 3: Keep enough ventilation space between the Switch and the surrounding objects.  
#Notice:  
When choosing a location, please keep in mind the environmental restrictions discussed in Chapter 1, Section 4,  
Specification.  
Step 4: Connect your Switch to network devices.  
A. Connect one end of a standard network cable to the 10/100/1000 RJ-45 ports on the front of the GSW-2416SF  
Switch.  
B. Connect the other end of the cable to the network devices such as printer servers, workstations or routers…etc.  
#Notice:  
Connection to the Switch requires UTP Category 5/5e/6 network cabling with RJ-45 tips. For more information, please  
see the Cabling Specification in Appendix A.  
Step 5: Supply power to the Switch.  
A. Connect one end of the power cable to the Switch.  
B. Connect the power plug of the power cable to a standard wall outlet then power on the Switch.  
When the Switch receives power, the Power LED should remain solid Green.  
2.3.2 Rack Mounting  
To install the Switch in a 19-inch standard rack, follow the instructions described below.  
Step 1: Place your Switch on a hard flat surface, with the front panel positioned towards your front side.  
Step 2: Attach a rack-mount bracket to each side of the Switch with supplied screws attached to the package. Figure  
2-3 shows how to attach brackets to one side of the Switch.  
Figure 2-3 Attaching the brackets to the Switch  
EM-GSW2416SFv1  
- 7 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Caution:  
You must use the screws supplied with the mounting brackets. Damage caused to the parts by using incorrect screws  
would invalidate your warranty.  
Step 3: Secure the brackets tightly.  
Step 4: Follow the same steps to attach the second bracket to the opposite side.  
Step 5: After the brackets are attached to the Switch, use suitable screws to securely attach the brackets to the rack, as  
shown in Figure 2-4.  
Figure 2-4 Mounting the Switch in a Rack  
Step 6: Proceed with the steps 4 and steps 5 of section 2.3.1 Desktop Installation to connect the network cabling and  
supply power to your Switch.  
EM-GSW2416SFv1  
- 8 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. SWITCH MANAGEMENT  
This chapter describes how to manage the GSW-2416SF. Topics include:  
- Overview  
- Management methods  
- Assigning an IP address to the GSW-2416SF  
- Logging on to the GSW-2416SF  
3.1 Overview  
This chapter gives an overview of switch management. The GSW-2416SF provides a user-friendly, command line under  
console interface and Simply WEB browser interface. Using these interfaces, you can perform various switch  
configuration and management activities, including:  
z
z
z
z
z
z
z
z
Port configuration  
VLAN Add/Remove/Assign  
Flow Control Enable/Disable  
Port Trunk Create/Assign ( WEB GUI supported )  
System IP address setting.  
Management account and password setting.  
Port status/static monitoring  
System reboot and reload factory default.  
Please refer to the following Chapter 4 and 5 for the details.  
3.2 Management Methods  
There are two ways to manage the GSW-2416SF:  
- Local Console Management via the Switch serial port.  
- Web Management via a network or dial-up connection.  
3.2.1 Local Console Management  
You can manage the GSW-2416SF locally by connecting a VT100 terminal, or a personal computer or workstation with  
terminal emulation software, to the Switch serial port. The terminal or workstation connects to the Switch serial port using a  
null modem cable that has the appropriate connectors on each end.  
This management method is ideal when:  
- The network is unreliable.  
- The Network Manager does not have direct network connection.  
The serial port of the Switch default setting is set to 19200 baud using a character format of 8 data bits, no parity, and 1  
stop bit.  
Therefore, configure the terminal or workstation to use these settings before you log on to the GSW-2416SF. You can  
change this default setting, if desired, after you log on.  
EM-GSW2416SFv1  
- 9 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3.2.2 Web Management  
You can manage the GSW-2416SF remotely by having a remote host with web browser, such as Microsoft Internet  
Explorer or Netscape Navigator.  
Using this management method:  
The GSW-2416SF must have an Internet Protocol (IP) address accessible for the remote host.  
3.3 Assigning an IP Address to the Switch  
To manage the GSW-2416SF remotely through the web browser with a Management Station, you must assign an IP  
address to the GSW-2416SF.  
To set the IP address, please use “set ip xxx.xxx.xxx.xxx mmm.mmm.mmm.mmm ggg.ggg.ggg.ggg” command. For  
example, to configure the switch with the following IP settings:  
IP Address: 192.168.0.100  
Subnet Mask: 255.255.255.0  
Default Gateway: 192.168.0.254  
Press the following command and press <Enter>  
set ip 192.168.0.100 255.255.255.0 192.168.0.254  
If the IP is successfully configured, the switch will apply the new IP address setting immediately. You can access the web  
interface of GSW-2416SF through the new IP address.  
EM-GSW2416SFv1  
- 10 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3.4 Logging on to the GSW-2416SF  
When you log on to the GSW-2416SF console port for the first time, a sign-on string appears and you are prompted for a  
console login user name and password.  
The factory default login username is admin without password.  
#Notice:  
1. For security reason, please change and memorize the new password after this first setup.  
2. Only accept command in lowercase letter under console interface.  
EM-GSW2416SFv1  
- 11 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4. CONSOLE INTERFACE  
4.1 CONNECT TO PC  
RS-232 serial cable  
Use the bundled RS-232 serial cable and attach the 9-pin female connector to the male connector on the  
GSW-2416SF. Plug the other side of this cable to your PC.  
Hyper Terminal  
In Windows 98/2000/ME/XP, launch “HyperTerminal”, create a new connection, and adjust settings as below:  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Emulation: VT-100 compatible  
Baud per second: 19200  
Data bits: 8  
Parity: None  
Stop bits: 1  
Flow Control: None  
To gain a demo, please see the Figure 4-1.  
Figure 4-1 Port Settings for console interface  
EM-GSW2416SFv1  
- 12 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.2 Login in  
Login is required to access the console interface after the self-test completes successfully. The factory default user name  
is "admin" without password. You may change the password by use “set pass” command. Please always enter the  
correct user name and password. (See Figure 4-2)  
Figure 4-2 GSW-2416SF login screen  
4.3 Main Menu screen  
After login the GSW-2416SF, the main menu screen shows as below.  
Figure 4-3 GSW-2416SF Main Menu screen  
EM-GSW2416SFv1  
- 13 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4 Getting Started  
4.4.1 General Guidelines  
The GSW-2416SF allows users to configure the device via command line under console interface. Please type “help” or  
“?” for all available commands in the”GSW-2416SF>” prompt. The screen of available commands in Figure 4-4 appears,  
and the detail description shown in Table 4-1.  
Figure 4-4 GSW-2416SF available commands screen  
Command  
Description  
show port  
Show all port current status of GSW-2416SF.  
Show per port TX/RX static of GSW-2416SF.  
Show current VLAN group status of GSW-2416SF.  
show static [n]  
show vlan  
Show current IP subnet address and default gateway information of  
GSW-2416SF.  
show ip  
show version  
show flowcontrol  
show vlantag  
show vlanaware  
show priority  
show pvid  
Show current Software and Hardware versions of GSW-2416SF.  
Show current flow control status on each port of GSW-2416SF.  
Show current VLAN Tagged status on each port of GSW-2416SF.  
Show current VLAN aware status on each port of GSW-2416SF.  
Show current priority status of GSW-2416SF.  
Show current PVID value on each port of GSW-2416SF.  
Show current VLAN ID of each VLAN Group of GSW-2416SF.  
show vid  
Set per port auto-negotiation, speed duplex mode, and admin down of  
GSW-2416SF.  
set port [n]  
set vlan [n]  
Assign port to specific VALN Group of GSW-2416SF.  
EM-GSW2416SFv1  
- 14 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
set flowcontrol [n]  
enable/disable  
Enable/Disable the flow control function to specific port [n] of GSW-2416SF.  
Enable/Disable the VLAN Tagging to specific egress port of GSW-2416SF.  
Enable/Disable VLAN-Aware function to specific port of GSW-2416SF.  
set vlantag [n]  
enable/disable  
set vlanaware [n]  
enable/disable  
set priority [n] [m]  
set pvid [n] [m]  
Allow to configure the priority setting of GSW-2416SF.  
Assign PVID on each port of GSW-2416SF.  
set vid [n] [m]  
Assign VLAN ID [m] to specific VLAN Group [n]  
set IP xxx.xxx.xxx.xxx,  
mmm. mmm, mmm, mmm, Assign IP address, subnet mask, gateway of GSW-2416SF.  
ggg.ggg.ggg.ggg  
set pass [oldpass]  
[newpass]  
Change the default password of GSW-2416SF, the maximum length is 8  
characters.  
factory default  
reboot  
Reset the GSW-2416SF to factory default mode.  
Reboot the GSW-2416SF.  
logout  
Logout console interface of GSW-2416SF.  
Table 4-1 Detail description of GSW-2416SF available commands  
#Notice: Only accept command in lowercase letter under console interface.  
4.4.2 Show command  
From the main menu screen (see Figure 4-3), input “show” and press enter. The show command list screen in Figure 4-5  
appears.  
Figure 4-5 Show command list screen  
This show command list contains eleven items:  
show port : Please refer to chapter 4.4.2.1.  
show static [n] : Please refer to chapter 4.4.2.2.  
show vlan : Please refer to chapter 4.4.2.3.  
show ip : Please refer to chapter 4.4.2.4.  
show version : Please refer to chapter 4.4.2.5.  
EM-GSW2416SFv1  
- 15 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
show flowcontrol : Please refer to chapter 4.4.2.6.  
show vlantag : Please refer to chapter 4.4.2.7.  
show vlanaware : Please refer to chapter 4.4.2.8.  
show priority : Please refer to chapter 4.4.2.9.  
show pvid : Please refer to chapter 4.4.2.10.  
show vid : Please refer to chapter 4.4.2.11.  
4.4.2.1 Show port  
Display the status on each port of GSW-2416SF, this command allows you to view the port status of the Switch and the  
correct usage is shown as below:  
Show port: to view all port status of GSW-2416SF. The screen in Figure 4-6 appears.  
Figure 4-6 All port Status screen  
4.2.2.2 Show static [n]  
Display the traffic static on specific port of GSW-2416SF, the content include the following items :  
z
z
z
z
TX OK: Number of transmitted packets.  
RX OK: Number of received packets.  
TX Error: Number of transmitted packets with error ( CRC error etc).  
RX Error: Number of received packets with error (CRC error etc).  
Show static [n]: n is the Port ID, n=1-24. To view one specific port static of GSW-2416SF, the port static screen in Figure  
4-7 appears.  
EM-GSW2416SFv1  
- 16 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 4-7 Per port static screen  
#Notice:  
The TX/RX packets counted with error might because:  
z
z
z
Packet with a bad FCS.  
Packets were less than 64 bytes or greater than 1522 bytes.  
Packets were dropped due to lack of resources.  
4.4.2.3 Show vlan [n]  
Display one specific VLAN group status of GSW-2416SF. GSW-2416SF supports up to 24-port based VLAN Groups and  
the correct usage is shown as below:  
Show vlan  
to view all VLAN Group and port member assigned status.  
n=1-24, to view one specific VLAN Group and port member assigned status.  
[n] is the VLAN Group ID.  
Show vlan [n]  
The specific VLAN Group status screen in Figure 4-8 appears.  
Figure 4-8 VLAN group status screen  
EM-GSW2416SFv1  
- 17 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.4.2.4 Show ip  
Display the current IP address, netmask and gateway of GSW-2416SF. The IP subnet address information screen in  
Figure 4-9 appears.  
Figure 4-9 IP subnet address information screen  
4.4.2.5 Show version  
Display the system information of GSW-2416SF, such as current software version and issued hardware version.  
The version information screen in Figure 4-10 appears.  
Figure 4-10 System information screen  
EM-GSW2416SFv1  
- 18 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.4.2.6 Show flowcontrol  
Display the flow control status on all ports of GSW-2416SF, this command allows you to view per port flow control status of  
the Switch.  
Enabled – 802.3x flow control is enabled on Full-Duplex mode or Backpressure is enabled on Half-Duplex mode..  
Disabled – No flow control or backpressure function on no matter Full-Duplex or Half-Duplex mode.  
The flow control status screen in Figure 4-11 appears.  
Figure 4-11 All ports flow control status screen  
4.4.2.7 Show vlantag  
Display the VLAN Tagging behavior on all ports of GSW-2416SF.  
Enabled - traffic is transmitted as tagged frames.  
Disabled -traffic is transmitted as untagged frames.  
The all ports VLAN Tagging status screen in Figure 4-12 appears.  
Figure 4-12 All ports VLAN Tagging status screen  
EM-GSW2416SFv1  
- 19 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.4.2.8 Show vlanaware  
Display current VLAN-aware status on each port of GSW-2416SF.  
Enabled – Tagged Frame remain original VID while leaving tagged port.  
Disabled - Tagged Frame wouldn’t remain original VID while leaving tagged port.  
The VLAN-aware status screen in Figure 4-13 appears.  
Figure 4-13 The VLAN-aware status screen  
4.4.2.9 Show priority  
Display the current priority status of GSW-2416SF.The allowed priority values are from 0-7. The priority status display  
screen in Figure 4-14 appears.  
Figure 4-14 Display 802.1p priority status screen.  
EM-GSW2416SFv1  
- 20 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.4.2.10 Show pvid  
Display the current per port PVID of GSW-2416SF. The Allowed PVID values are form 0-4095. The per port PVID display  
screen in Figure 4-15 appears.  
Figure 4-15 Display PVID screen  
4.4.2.11 Show vid  
Display the current VLAN ID of each VLAN Group, the VLAN Groups and ID mapping status display screen in Figure 4-16  
appears.  
Figure 4-16 VLAN ID of each VLAN Group status screen  
EM-GSW2416SFv1  
- 21 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.4.3 Set command  
From the main menu screen (see Figure 4-3), input “set” and press enter. The set command list screen in Figure 4-17  
appears.  
Figure 4-17 Set command list screen  
This set command list contains ten items:  
Set port [n]: Please refer to chapter 4.4.3.1.  
Set vlan [n]: Please refer to chapter 4.4.3.2.  
Set flowcontrol [n] enable/disable: Please refer to chapter 4.4.3.3.  
Set vlantag [n] enable/disable: Please refer to chapter 4.4.3.4  
Set vlanaware [n] enable/disable: Please refer to chapter 4.4.3.5  
Set priority [n] [m]: Please refer to chapter 4.4.3.6  
Set pvid [n] [m]: Please refer to chapter 4.4.3.7  
Set vid [n] [m]: Please refer to chapter 4.4.3.8  
Set ip xxx.xxx.xxx.xxx.mmm.mmm.mmm.mmm.ggg.ggg.ggg.ggg: Please refer to chapter 4.4.3.9  
Set pass [oldpass] [newpass]: Please refer to chapter 4.4.3.10  
EM-GSW2416SFv1  
- 22 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.3.1 Set port [n]  
This command allows configuring per port parameters of GSW-2416SF. the correct usage is shown as below:  
Set port [n]: n=1-24, to configuring per port parameters of GSW-2416SF.  
Default setting: (1) Auto Speed  
The configuring per port parameters screen in Figure 4-18 appears and the detail description shown in table 4-2.  
Figure 4-18 Port Configuration screen  
Object  
Description  
(1) Auto Speed  
(2) 10 Half  
Setup Auto negotiation of each port.  
Force sets 10Mbps/Half-Duplex mode for specific port.  
Force sets 10Mbps/Full-Duplex mode for specific port.  
Force sets 100Mbps/Half-Duplex mode for specific port.  
Force sets 100Mbps/Full-Duplex mode for specific port.  
Force sets 10000Mbps/Full-Duplex mode for specific port.  
Disable or Shutdown the specific port  
(3) 10 Full  
(4) 100 Half  
(5) 100 Full  
(6) 1000 Full  
(7) Disable  
Table 4-2 Descriptions of the Port Configuration screen Objects  
4.4.3.2 Set vlan [n]  
This command allows configuring up to 24-port based VLAN Groups of GSW-2416SF. The correct usage is shown as  
below:  
Set vlan [n]: n=1-24, to configuring 24 VLAN Groups of GSW-2416SF. [n] is the VLAN Group ID. And the following  
message appears:  
Please input port number (1-24), exit press enters: Add/Remove port to the current VLAN Group, “*” means port had  
been assign to the VLAN Group.  
Default setting: none  
The configuring VLAN Groups screen in Figure 4-19 appears. (Assign port 1, port 6 and port 7 to VLAN Group 1)  
EM-GSW2416SFv1  
- 23 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 4-19 VLAN members Configuration screen  
#Notice:  
Change VLAN settings for every time, you have to reboot the switch to apply new settings.  
4.4.3.3 Set flowcontrol  
This command allows configuring per port flow control function of GSW-2416SF. The correct usage is shown as below:  
Set flowcontrol [n] enable/disable  
[n]=1-24, n is the specific Port ID.  
Enable – 802.3x flow control is enabled on Full-Duplex mode or Backpressure is enabled on Half-Duplex mode.  
Disable – No flow control or backpressure function on no matter Full-Duplex or Half-Duplex mode.  
Default setting: Enable  
The configuring per port flow control screen in Figure 4-20 appears.  
Figure 4-20 Flow Control port Configuration screen  
EM-GSW2416SFv1  
- 24 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.4.3.4 Set vlantag  
This is an additional function of VLAN configuration.  
This command allows configuring per port VLAN Tagged/Untagged status. When adding a VLAN to selected port, it tells  
the switch whether to keep or remove the tag from a frame on egress. The correct usage is shown as below:  
Set vlantag [n] enable/disable  
[n]=1-24, n is the specific Port ID.  
Enable – keep the tag from a frame on egress.  
Disable – Remove the tag from a frame on egress.  
Default Setting: Disable  
The configuring per port VLAN Tagging screen in Figure 4-21 appears.  
Figure 4-21 Per Port VLAN Tagging Configuration screen  
#Notice:  
Change VLAN settings for every time, you have to reboot the switch to apply new settings.  
4.4.3.5 Set vlanaware  
This is an additional function of VLAN configuration.  
This command allows disable or enable per port vlan aware function of GSW-2416SF. The correct usage is shown as  
below:  
Set vlanaware [n] enable/disable  
[n]=1-24, n is the specific Port ID.  
Enabled – Tagged Frame remain original VID while leaving tagged port.  
Disabled - Tagged Frame wouldn’t remain original VID while leaving tagged port.  
Default Setting: Disable  
The vlan-aware mode setting screen in Figure 4-22 appears  
EM-GSW2416SFv1  
- 25 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 4-22 VLAN aware Configuration screen  
#Notice:  
Change VLAN settings for every time, you have to reboot the switch to apply new settings.  
4.4.3.6 Set priority  
This command configures the default 802.1p port priority assigned for untagged packets for a specific port of  
GSW-2416SF. The correct usage is shown as below:  
Set priority [n] [m]  
[n]=1-24, n is the specific Port ID of GSW-2416SF.  
[m] = 0-7, m is 802.1p priority.  
Default Setting: 0  
The per port priority setting screen in Figure 4-23 appears. (Set Port 1 with priority “7”)  
Figure 4-23 Priority Configuration screen  
EM-GSW2416SFv1  
- 26 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.4.3.7 Set pvid  
This is an additional function of VLAN configuration.  
This command allows assign PVID for selected port of GSW-2416SF. The correct usage is shown as below:  
Set pvid [n] [m]  
[n]=1-24, n is the specific Port ID of GSW-2416SF.  
[m] = 1-4095, 0 reserved for management purpose; m is allowed VLAN ID.  
Default Setting: 0  
To remote control the GSW-2416SF, the connect port have to set with PVID=0  
The PVID setting screen in Figure 4-24 appears. (Example: Set Port 1 with PVID=3)  
Figure 4-24 PVID Configuration screen  
#Notice:  
Change VLAN settings for every time, you have to reboot the switch to apply new settings.  
4.4.3.8 Set vid  
This command allows assign VLAN ID for specific VLAN Group of GSW-2416SF. The correct usage is shown as below:  
Set vid [n] [m]  
[n]=1-24, n is the specific VLAN Group of GSW-2416SF.  
[m] = 0-4095, m is allowed VLAN ID.  
Default Setting: 0  
The VID setting screen in Figure 4-25 appears. (Example: Set VALN Group 2 with VLAN ID=3)  
EM-GSW2416SFv1  
- 27 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 4-25 VID Configuration screen  
#Notice:  
Change VLAN settings for every time, you have to reboot the switch to apply new settings.  
4.4.3.9 Set ip xxx.xxx.xxx.xxx.mmm.mmm.mmm.mmm.ggg.ggg.ggg.ggg  
This command allows assign IP address, netmask and gateway of GSW-2416SF. The correct usage is shown as below:  
set ip 192.168.0.1 255.255.255.0 192.168.0.254 and press <Enter>  
After the setting be completed, you can use the new IP address to access the WEB UI of GSW-2416SF.  
Default Setting:  
IP: 192.168.0.100  
Netmask: 255.255.255.0  
Default Gateway: 192.168.0.254  
The IP subnet address setting screen in Figure 4-26 appears.  
EM-GSW2416SFv1  
- 28 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 4-26 IP subnet address configuration screen  
4.4.3.10 Set pass  
This command allows assign password of GSW-2416SF. The correct usage is shown as below:  
set pass [oldpass] [newpass]  
Default Setting: no password  
#Notice: The symbol “[“ and “]” are required for both old password and new password. And once the  
setting be completed, the next time login have to use the new password.  
The password setting screen in Figure 4-27 appears. (Example: Setting new password =” test “)  
Figure 4-27 Password configuration screen  
#Notice:  
1. For security reason, please change and memorize the new password after this first setup.  
2. The maximum length is 8 characters.  
EM-GSW2416SFv1  
- 29 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.4.4 Factory default  
This command allows rest GSW-2416SF to factory default mode. The factory default screen in Figure 4-28 & 4-29 appears.  
Figure 4-28 Factory default screen  
Figure 4-29 Factory default screen  
EM-GSW2416SFv1  
- 30 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.5 Reboot  
This command allows reboot GSW-2416SF, the reboot screen in Figure 4-30 & 4-31 appears.  
Figure 4-30 Switch reboot screen  
Figure 4-31 Switch reboot screen  
EM-GSW2416SFv1  
- 31 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.6 Logout  
This command provides logout the GSW-2416SF, the screen in Figure 4-32 appears.  
Figure 4-32 GSW-2416SF Logout screen  
EM-GSW2416SFv1  
- 32 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.5 Firmware Update  
This section will show you how to use X-modem to update the firmware of GSW-2416SF.  
Firmware update requirements  
GSW-2416SF switch  
Latest firmware version  
VT100 terminal, or a personal computer or workstation with terminal emulation software  
RS-232/DB9 null modem cable  
Update procedure:  
1.  
After login the GSW-2416SF, enter “update” in the”GSW-2416SF>” prompt. Then the message will ask you to use  
the Xmodem to send the firmware file. The firmware update screen in Figure 4-33 appears:  
Figure 4-33 Firmware Update  
2.  
Select and send the firmware file by your terminal emulation software. As the screens show in Figure 4-34 and Figure  
4-35:  
#Notice:  
1.  
Make sure that you had selected the correct firmware file that just for the GSW-2416SF and read the release note  
before you run the update procedure.  
2.  
Don’t power off the switch while updating firmware or unexpected result occurred.  
EM-GSW2416SFv1  
- 33 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 4-34 Firmware Update  
Figure 4-35 Xmodem transmit  
After the file send be completed, the system will reboot automatically to the login screen. You can check if the  
Software version been updated. The screen in Figure 4-36 appears:  
Figure 4-36 System reboot screen  
EM-GSW2416SFv1  
- 34 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. WEB MANAGEMENT  
Before login the Web interface of GSW-2416SF, please setup the “IP Address” with local serial console port (RS232 port)  
and use this IP address to configure GSW-2416SF through the Web interface.  
Or modify your PC’s IP domain to the same with GSW-2416SF then use the default IP address (192.168.0.100) to remote  
configure GSW-2416SF through the Web interface.  
5.1 Login in to the Switch  
To access the Web-browser interface you must first enter the user name, the default user name is "admin" without  
password. You will see the following screen comes out on the Web browser program:  
Figure 5-1 The GSW-2416SF login Web Page screen  
After the User name and Password is entered, you will see the web main menu screen.  
Figure 5-2 The web main menu screen of GSW-2416SF  
EM-GSW2416SFv1  
- 35 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5.2 Port Config  
This section provides current ports status and detail setting of each port of GSW-2416SF. The screen in Figure 5-3  
appears and Table 5-1 describes the port configuration object of switch.  
Figure 5-3 GSW-2416SF Port Configuration Web Page screen  
#Notice:  
Due to VID value “0” is reserved for management purpose, the management linked port have to configured with PVID=0.  
For example: The management PC connected to Port-24 of the switch via Ethernet. Port-24 has to be configured with  
PVID=0, and the management has to be configured within the same domain as the switch.  
EM-GSW2416SFv1  
- 36 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Object  
Port  
Description  
Indicate port 1 to port 24.  
Mode  
Allow configuring the port speed and operation mode. Draw the menu bar to select the mode.  
z
z
z
z
z
z
z
Auto Speed - Setup Auto negotiation.  
10 half  
- Force sets 10Mbps/Half-Duplex mode.  
10 Full  
- Force sets 10Mbps/Full-Duplex mode.  
- Force sets 100Mbps/Half-Duplex mode.  
- Force sets 100Mbps/Full-Duplex mode.  
- Force sets 10000Mbps/Full-Duplex mode.  
- Shutdown the port manually.  
100 half  
100 full  
1000 full  
Disable  
Flow Control  
Allow Enable or Disable flow control for selected port.  
Enable – 802.3x flow control is enabled on Full-Duplex mode or Backpressure is enabled on  
Half-Duplex mode.  
Disable – No flow control or backpressure function on no matter Full-Duplex or Half-Duplex mode  
VLAN aware  
Allow Enable or Disable VLAN aware for selected port.  
* Additional function  
Enable – Tagged Frame remain original VID while leaving tagged port.  
Disable - Tagged Frame wouldn’t remain original VID while leaving tagged port.  
VLAN tag  
Allow Enable or Disable VLAN Tag for selected port.  
* Additional function  
When adding a VLAN to selected port, it tells the switch whether to keep or remove the tag from a  
frame on egress.  
Enable - Outgoing frames with VLAN-Tagged.  
Disable - Outgoing frames without VLAN-Tagged.  
VLAN priority  
Allow assign 802.1p priority for selected port.  
The range for the priority is 0-7 (0~3 for low priority; 4~7 for high priority )  
PVID  
Allow assign PVID for selected port.  
The range for the PVID is 1-4095 ; 0 reserved for management purpose  
* Additional function  
The PVID will be inserted into all untagged frames entering the ingress port. The PVID must as same  
as the VLAN ID that the port belong to VLAN group, or the untagged traffic will be dropped.  
Table 5-1 Descriptions of the Port Configuration screen Objects  
Click “Apply” button to affect the configured function.  
#Notice:  
Change VLAN settings for every time, you have to reboot the switch to apply new settings.  
VLAN Tag:  
Tagged-based VLAN is an IEEE 802.1Q specification standard. Therefore, it is possible to create a VLAN across devices  
from different switch venders. IEEE 802.1Q VLAN uses a technique to insert a "tag" into the Ethernet frames. Tag contains  
a VLAN Identifier (VID) that indicates the VLAN numbers.  
To set the outgoing frames are VLAN-Tagged frames or untagged.  
Tag: outgoing frames with VLAN-Tagged.  
UnTag: outgoing frames without VLAN-Tagged.  
PVID:  
Set the PVID that will be assigned to untagged traffic on a given port. This feature is useful for accommodating devices that  
you want to participate in the VLAN but that don't support tagging. The switch each port allows user to set one PVID, the  
range is 0~4095, default VLAN ID is 0. The PVID must as same as the VLAN ID that the port belong to VLAN group( See  
chapter 5.3 – VLAN Setup), or the untagged traffic will be dropped.  
EM-GSW2416SFv1  
- 37 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.3 VLAN Setup  
A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain. It allows you to isolate network traffic  
so only members of the VLAN receive traffic from the same VLAN members. Basically, creating a VLAN from a switch is  
logically equivalent of reconnecting a group of network devices to another Layer 2 switch. However, all the network devices  
are still plug into the same switch physically.  
The GSW-2416SF switch supports Port-Base VLAN setting in web management page. In the default configuration, VLAN  
support is “disable”.  
5.3.1 VLAN Group and member settings  
This section provides current status and member setting of each VLAN group of GSW-2416SF, the screen in Figure 5-4  
appears.  
Figure 5-4 GSW-2416SF VLAN Settings Web Page screen  
1. Enter VLAN ID for the selected VLAN group. There are maximum 24 VLAN groups to provide configured and the  
range for the VLAN ID is 1-4095; 0 reserved for management purpose.  
2. Checked the Member box to select the members for the VLAN group.  
3. After setup completed, please press “Apply” to take affect.  
4. To setup another VLAN Group, click the VLAN Group ID button. After the web page load completed, repeat the  
previous steps.  
5. To remove a port from specific VLAN group, just cancel the Member check Box and press “Apply” to take affect.  
#Notice:  
Change VLAN settings for every time, you have to reboot the switch to apply new settings.  
EM-GSW2416SFv1  
- 38 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5.3.2 VLAN setting example:  
5.3.2.1 Two separate VLAN  
The diagram shows how the switch handle Tagged and Untagged traffic flow for two VLANs. VLAN Group 2 and VLAN  
Group 3 are separated VLAN. Each VLAN isolate network traffic so only members of the VLAN receive traffic from the  
same VLAN members. The screen in Figure 5-5 appears and Table 5-2 describes the port configuration of switch.  
Figure 5-5 two separate VLAN diagram  
VLAN Group  
VLAN Group 1  
VLAN Group 2  
VLAN Group 3  
VID  
1
Untagged Members  
Port-1,Port-2  
Tagged Members  
Port-3  
2
Port-4,Port-5  
Port-6  
3
Port-7~Port-24  
N/A  
Table 5-2 VLAN and Port Configuration  
The scenario described as follow:  
Untagged packet entering VALN 2  
1.  
While [PC-1] transmit an untagged packet enters Port-1, the switch will tag it with a VLAN Tag=2. [PC-2] and  
[PC-3] will received the packet through Port-2 and Port-3.  
2.  
3.  
4.  
[PC-4],[PC-5] and [PC-6] received no packet.  
While the packet leaves Port-2, it will be stripped away it tag becoming an untagged packet.  
While the packet leaves Port-3, it will keep as a tagged packet with VLAN Tag=2.  
Tagged packet entering VLAN 2  
5.  
6.  
While [PC-3] transmit a tagged packet with VLAN Tag=2 enters Port-3, [PC-1] and [PC-2] will received the  
packet through Port-1 and Port-2.  
While the packet leaves Port-1 and Port-2, it will be stripped away it tag becoming an untagged packet.  
Untagged packet entering VLAN 3  
1.  
While [PC-4] transmit an untagged packet enters Port-4, the switch will tag it with a VLAN Tag=3. [PC-5] and  
[PC-6] will received the packet through Port-5 and Port-6.  
2.  
3.  
While the packet leaves Port-5, it will be stripped away it tag becoming an untagged packet.  
While the packet leaves Port-6, it will keep as a tagged packet with VLAN Tag=3.  
#Notice:  
At this example, VLAN Group 1 just set as default VLAN, but only focus on VLAN 2 and VLAN 3 traffic flow.  
EM-GSW2416SFv1  
- 39 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Setup steps  
1.  
VLAN Group  
Set VALN Group 1 = default-VLAN with VID (VLAN ID)=1  
Add two VLANs – VLAN 2 and VLAN 3  
VLAN Group 2 with VID=2  
VLAN Group 3 with VID=3  
2.  
3.  
4.  
Assign VLAN Member :  
VLAN 2: Port-1, Port-2 and Port-3  
VLAN 3: Port-4, Port-5 and Port-6  
VLAN 1: All other ports – Port-7~Port-24  
Assign PVID for each port:  
Port-1, Port-2 and Port-3: PVID=2  
Port-4, Port-5 and Port-6: PVID=3  
Port-7~Port-24: PVID=1  
Enable VLAN Tag for specific ports  
VLAN Tag Enabled: Port-3 (VLAN-2) and Port-6 (VLAN-3)  
The Port VLAN configuration would be as the following screen in Figure 5-6.  
Figure 5-6 Port Configuration Web page screen  
EM-GSW2416SFv1  
- 40 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 5-7 VLAN 1 member assign Web page screen  
Figure 5-8 VLAN 2 member assign Web page screen  
EM-GSW2416SFv1  
- 41 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 5-9 VLAN 2 member assign Web page screen  
#Notice:  
Change VLAN settings for every time, you have to reboot the switch to apply new settings.  
5.3.2.2 Overlap VLAN  
The scenario described as follow:  
1. Port-16 is the file server port for all the workstations  
2. Port-1 to Port-15 is different devices that do need to see each other  
Setup steps  
1. Port Setting  
1.1 Assign VLAN 1 as the default VLAN group for all ports  
1.2 Assign VLAN 2 for the second VLAN group with Port-1 and Port-16  
1.3 Repeat the same steps for Port-2 to Port-15. i.e. 2 & 16, 3 & 16, ….., 15 & 16  
2. PVID setup  
2.1 Assign “1” (i.e. ID of VLAN 1) to Port-16 as its PVID (Port VLAN ID).  
2.2 Assign “2” to Port-1 as its PVID  
2.3 Repeat above steps for Port-2 to Port-15 with its PVID, i.e. 3 (Port-2), 4 (Port-3), to 16 (Port-15)  
After the above steps Port-1 to Port-15 is being separated physically due to it belongs to different VLAN  
groups (different VLAN). However, they all can access Port-16 due to Port-16 is using PVID 1 to communicate  
with port 1 to port 15.  
#Notice:  
Change VLAN settings for every time, you have to reboot the switch to apply new settings.  
EM-GSW2416SFv1  
- 42 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.4 Port Trunk Setup  
This section allows you to disable or enable trunk function of two ports or four ports together to speed up data transmission.  
The GSW-2416SF provides up to 3 Trunk group, each group supports maximum 4 ports, the screen in Figure 5-10  
appears.  
Figure 5-10 GSW-2416SF Port Trunk Setup Web Page screen  
To configure the Port Trunk, with the specific Trunk ID, select Member ports to meet required. The screen in Figure 5-11  
appears:  
Figure 5-11 GSW-2416SF Port Trunk Setup Web Page screen  
The Trunk group and members are fixed assign. Please refer to the following table:  
ID  
01  
Member  
z
z
z
Disable  
01,02  
01,02,03,04  
z
z
z
Disable  
09,10  
09,10,11,12  
02  
03  
z
z
z
Disable  
17,18  
17,18,19,20  
EM-GSW2416SFv1  
- 43 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
#Notice:  
1. After turn on the port trunk feature, port 1 and port 2 or port 17,18,19,20 should connect to another switch,  
such as another GSW-2416SF, that also supports port trunk feature to double the bandwidth in between.  
Otherwise, if the connected switch do not support port trunk, it will cause network loop and hangs the whole  
network.  
2. The GSW-2416SF doesn’t support LACP (Link Aggregation control Protocol) trunk type yet. Connect with  
LACP type switch the trunk function might be failed.  
3. Within the same Trunk Group, the member ports have to be configured with the same settings, such as port speed and  
VLAN etc.  
EM-GSW2416SFv1  
- 44 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.5 Status  
5.5.1 Port Status  
This section displayed the current link status of each port on GSW-2416SF. It’s help the manager easy to get the  
connection info. The screen in Figure 5-12 appears.  
Figure 5-12 GSW-2416SF Port Status Web Page screen  
5.5.2 Statistics  
This section displayed the current traffic statistics of each port on GSW-2416SF. The screen in Figure 5-13 appears.  
The content of the statistics table include the following items:  
z
z
z
z
TX OK: Number of transmitted packets.  
RX OK: Number of received packets.  
TX Error: Number of transmitted packets with error ( CRC error etc).  
RX Error: Number of received packets with error (CRC error etc).  
(The unit of the above value is “packets”)  
#Notice:  
The TX/RX packets counted with error might because:  
z
z
z
Packet with a bad FCS.  
Packets were less than 64 bytes or greater than 1522 bytes.  
Packets were dropped due to lack of resources.  
EM-GSW2416SFv1  
- 45 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 5-13 GSW-2416SF Port Statistics Web Page screen  
There’re also two buttons at the statistics web page – “Clear” and “Refresh”.  
Press the “Clear” button will clear the current traffic statistic value.  
Press the “Refresh” button will update the latest traffic statistic value, especially for the traffic keeps on transmitting.  
EM-GSW2416SFv1  
- 46 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.6 Misc Configuration  
This section provides Misc Configuration of GSW-2416SF.  
5.6.1 System Setup  
This section provides System Configuration of GSW-2416SF, the screen in Figure 5-14 appears and table 5-4 descriptions  
the System Configuration objects of GSW-2416SF.  
Figure 5-14 GSW-2416SF System Configuration Web Page screen  
Object  
Description  
Mac address  
S/W Version  
H/W Version  
Display Mac address of GSW-2416SF.  
Display firmware version of GSW-2416SF.  
Display Hardware version of GSW-2416SF  
Allow user to assign new IP address of GSW-2416SF, after setup completed.  
Please press “Apply” button and switch will take effect immediately.  
IP Address  
Allow user to assign new Subnet Mask of GSW-2416SF, after setup completed.  
Please press “Apply” button and switch will take effect immediately.  
Subnet Mask  
Allow user to assign new Gateway of GSW-2416SF, after setup completed. Please press  
“Apply” button and switch will take effect immediately.  
Gateway  
Name  
Display the administrator account of the switch. Default account is “admin”  
Allow user to change the password and maximum up to 8 characters  
Please press “Apply” button and switch will take effect immediately.  
Password  
Table 5-4 Descriptions of the System Configuration screen Objects  
Once the setup completed and the IP address of the device be changed, you might loss the web connection. Modify your  
PC’s IP domain to the same with the new IP address of GSW-2416SF.  
EM-GSW2416SFv1  
- 47 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5.7 Tools  
This section provides two management tools of GSW-2416SF- Reboot and Factory Reset.  
5.7.1 Reboot  
This section provides reboot GSW-2416SF, after choose this function and the following screen appears in Figure 5-15.  
Please press “Warm Reboot” button to take effect immediately. After system reboot, the manager has to refresh the  
browser and re-login web interface with correct username “admin” and password, the screen in Figure 5-16 appears.  
Figure 5-15 The GSW-2416SF reboot system Web Page screen  
Figure 5-16 The GSW-2416SF login Web Page screen  
EM-GSW2416SFv1  
- 48 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5.7.2 Factory Reset  
This section provides reset GSW-2416SF to factory default mode, default value to as following configuration:  
z
z
z
z
Default IP address: 192.168.0.100  
Subnet mask: 255.255.255.0  
Default Gateway: 192.168.0.254  
The other setting value is back to disable or none.  
After choose this function and the following screen appears in Figure 5-17.  
Figure 5-17 The GSW-2416SF reset to factory default Web Page screen  
Please press “Factory Reset” button to take effect and the switch will reboot automatically. After system reboot, the  
manager has to refresh the browser and re-login web interface with default username “admin” without password, the  
screen in Figure 5-18 appears.  
Figure 5-18 The GSW-2416SF login Web Page screen  
EM-GSW2416SFv1  
- 49 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5.8 Logout  
This section allows to logout the GSW-2416SF. Press “Logout” item in the Web Menu, it take effect immediately. If the  
manager wants to re-login, press the “Re-Login” button. The screen in Figure 5-19 and Figure 5-20 appears.  
Figure 5-19 The GSW-2416SF Logout Web Page screen  
Figure 5-20 The GSW-2416SF login Web Page screen  
EM-GSW2416SFv1  
- 50 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6. SWITCH OPERATION  
6.1 Address Table  
The Switch is implemented with an address table. This address table composed of many entries. Each entry is used to  
store the address information of some node in network, including MAC address, port no, etc. This information comes  
from the learning process of Ethernet Switch.  
6.2 Learning  
When one packet comes in from any port. The Switch will record the source address, port no. And the other related  
information in address table. This information will be used to decide either forwarding or filtering for future packets.  
6.3 Forwarding & Filtering  
When one packet comes from some port of the Ethernet Switching, it will also check the destination address besides  
the source address learning. The Ethernet Switching will lookup the address-table for the destination address. If not  
found, this packet will be forwarded to all the other ports except the port which this packet comes in. And these ports  
will transmit this packet to the network it connected. If found, and the destination address is located at different port  
from this packet comes in, the Ethernet Switching will forward this packet to the port where this destination address is  
located according to the information from address table. But, if the destination address is located at the same port with  
this packet comes in, then this packet will be filtered. Thereby increasing the network throughput and availability.  
6.4 Store-and-Forward  
Store-and-Forward is one type of packet-forwarding techniques. A Store-and Forward Ethernet Switching stores the  
incoming frame in an internal buffer, do the complete error checking before transmission. Therefore, no error packets  
occurrence, it is the best choice when a network needs efficiency and stability.  
The Ethernet Switch scans the destination address from the packet-header, searches the routing table provided for  
the incoming port and forwards the packet, only if required. The fast forwarding makes the switch attractive for  
connecting servers directly to the network, thereby increasing throughput and availability. However, the switch is most  
commonly used to segment existing hubs, which nearly always improves overall performance. An Ethernet Switching  
can be easily configured in any Ethernet network environment to significantly boost bandwidth using conventional  
cabling and adapters.  
Due to the learning function of the Ethernet switching, the source address and corresponding port number of each  
incoming and outgoing packet are stored in a routing table. This information is subsequently used to filter packets  
whose destination address is on the same segment as the source address. This confines network traffic to its  
respective domain, reducing the overall load on the network.  
The Switch performs "Store and forward" therefore, no error packets occur. More reliably, it reduces the  
re-transmission rate. No packet loss will occur.  
6.5 Auto-Negotiation  
The STP ports on the GSW-2416SF Switch have built-in “Auto-negotiation”. This technology automatically sets the  
best possible bandwidth when a connection is established with another network device (usually at Power On or Reset).  
This is done by detect the modes and speeds at the second of both device is connected and capable of, Both  
10Base-T and 100Base-TX devices can connect with the port in either Half- or Full-Duplex mode. 1000Base-T can be  
only connected in Full-duplex mode.  
EM-GSW2416SFv1  
- 51 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7.TROUBLESHOOTING  
This chapter contains information to help you solve problems. If the Switch is not functioning properly, make sure the  
Ethernet Switch was set up according to instructions in this manual.  
The Link LED is not lit  
Solution:  
Check the cable connection and remove duplex mode of the Switch.  
Some stations cannot talk to other stations located on the other port  
Solution:  
Please check the VLAN, port trunking function that may introduce this kind of problem.  
Performance is bad  
Solution:  
Check the full duplex status of the Ethernet Switch. If the Ethernet Switch is set to full duplex and the partner is set to  
half duplex, then the performance will be poor.  
100Base-TX port link LED is lit, but the traffic is irregular  
Solution:  
Check that the attached device is not set to dedicate full duplex. Some devices use a physical or software switch to  
change duplex modes. Auto-negotiation may not recognize this type of full-duplex setting.  
Why the Switch doesn’t connect to the network  
Solution:  
Check the LNK/ACT LED on the switch Try another port on the Switch Make sure the cable is installed properly Make  
sure the cable is the right type Turn off the power. After a while, turn on power again.  
How to deal forgotten password situation of GSW-2416SF?  
Solution:  
1. Please contact Planet switch support team and the mail address is [email protected]  
EM-GSW2416SFv1  
- 52 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
APPENDIX A NETWORKING CONNECTION  
A.1 Switch‘s RJ-45 Pin Assignments  
10/100Base-TX  
Contact  
MDI  
MDI-X  
1
1 (TX +)  
3
2
2 (TX -)  
3 (RX +)  
6 (RX -)  
Not used  
6
3
6
1
2
4, 5, 7, 8  
Not used  
A.2 1000Mbps, 1000Base-T  
Contact  
MDI  
MDI-X  
1
2
3
4
5
6
7
8
BI_DA+  
BI_DA-  
BI_DB+  
BI_DC+  
BI_DC-  
BI_DB-  
BI_DD+  
BI_DD-  
BI_DB+  
BI_DB-  
BI_DA+  
BI_DD+  
BI_DD-  
BI_DA-  
BI_DC+  
BI_DC-  
Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly  
forbidden, is beyond the scope of this standard.  
A.3 RJ-45 cable pin assignment  
21  
3
6
6
321  
6
3
2
1
There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation  
and color of straight cable and crossover cable connection:  
EM-GSW2416SFv1  
- 53 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure A-1: Straight-Through and Crossover Cable  
Please make sure your connected cables are with same pin assignment and color as above picture before deploying the  
cables into your network.  
2080-A82050-000  
EM-GSW2416SFv1  
- 54 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Speaker System 10P User Manual
Pelco DVR C623M C User Manual
Pentax Digital Camera 15507 User Manual
Petsafe Pet Care Product EC216 User Manual
Philips Computer Drive SNU6500 User Manual
Philips MP3 Docking Station WAC7500 User Manual
Philips Speaker System MMS 306 A User Manual
Philips Two Way Radio SBC SC 366 User Manual
Philips VCR SWV2202W User Manual
Philips VCR VR1010 User Manual