Perreaux Stereo Amplifier 200 User Manual

MODEL 200/200P  
DUAL CHANNEL POWER AMPLIFIER  
OWNERS MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The mains power supply cord should be  
routed so that it is not likely to be walked  
on or pinched by items placed on or  
against it. Pay particular attention to the  
cord at power points, convenience  
receptacles, and the point where it exits  
from the 200P.  
2. Follow Instructions  
13. Servicing  
The user should not attempt to service  
All installation, operation and other  
instructions should be followed.  
the 200P beyond those means described  
in the owners manual. All other servicing  
should be referred to qualified service  
personnel.  
3. Warnings  
All warnings on the 200P and in the  
Owners Manual should be strictly  
adhered to.  
14.  
Grounding or Polarisation  
9. Cleaning  
Precautions should be taken so that the  
grounding or polarisation of the 200P are  
correct, and are maintained through-out  
the entire system.  
When cleaning ‘P’ series product use  
luke warm water with a few drops of a  
mild non caustic detergent .  
4. Water and Moisture  
The 200P should not be used near water,  
for example near a bathtub, washbowl,  
kitchen sink, laundry tub, in a wet  
basement, near a swimming pool, etc.  
DO NOT USE SOLVENTS.  
WARNING: THE 200P IS  
POWERED CONVECTION  
AMPLIFIER. THE FINNED OUTER HEAT  
SINKS MAY BECOME VERY HOT WHEN  
DELIVERING HIGH VOLUME LEVELS - TO  
AVOID INJURY CARE SHOULD BE TAKEN  
A
HIGH  
10. Non-use Periods  
COOLED  
The mains power cord of the 200P  
should be unplugged from the mains/line  
outlet when the unit is to be left unused  
for long periods of time.  
5. Rack / Wall / Ceiling Mounting  
The 200P should be rack mounted only  
in a heavy duty rack or stand that is  
recommended for audio equipment use.  
Mounting to a wall or ceiling should be  
via a heavy duty bracket or shelf  
designed for audio equipment use.  
NOT TO  
TOUCH THE HEAT SINKS  
11. Object and Liquid Entry  
Care should be taken so that objects  
and/or liquids do not accidentally fall  
inside the 200P.  
DURING OPERATION.  
6. Heat  
The 200P should be situated away from  
heat sources such as radiators, stoves,  
or other appliances that produce  
excessive amounts of heat. Always  
ensure the 200P heat sinks have  
12. Damage Requiring Service  
The 200P should be serviced by qualified  
service personnel if any of the following  
occur :  
a. The mains power-supply cord,  
and/or plug have been damaged  
b. Objects have fallen, or liquid has  
been spilt into the 200P  
adequate  
ventilation  
enabling  
air  
circulation both above and below. Do not  
place the 200P directly onto carpeted  
surfaces.  
IMPORTANT INFORMATION  
c. The 200P has been exposed to  
rain and/or excessive moisture  
d. The 200P does not appear to  
operate normally, or exhibits a  
marked change in performance  
e. The 200P has been dropped, or  
the chassis damaged.  
7. Power Sources  
The 200P should be connected to a  
mains power supply only of the type  
described in the operating instructions, or  
as marked on the rear of the 200P.  
Always make sure the volume control of your  
preamplifier or source unit is set to zero and  
the mains/line supply disconnected from your  
200P prior to performing any switching  
functions or connection alterations of any  
type to your system. This caution also applies  
8. Power Cord Protection  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
to the normal use of your Compact Disc  
player, Tuner, Cassette Deck, etc.  
-
-
The  
wire  
which  
is  
coloured  
loop noise and aids in the cancellation of  
distortion products.  
GREEN/YELLOW must be connected to  
the terminal which is marked with the  
letter  
Balanced Line input pin configuration  
E,  
or  
colour  
coded  
Always ensure that there is adequate  
ventilation around the 200P and sufficient  
space to circulate air both below and  
above the unit. Do not place unit directly  
onto carpeted surfaces.  
Pin 1  
Pin 2  
Pin 3  
EARTH / Ground  
HOT / Phase  
COLD / Anti-phase  
GREEN/YELLOW or GREEN.  
Note : Any modifications to the mains/line  
voltage setting within your 200P may only be  
carried out by a qualified Perreaux service  
agent. Failure to recognise this warning will  
void any warranty.  
4. INPUT CONFIGURATION SWITCH  
This toggle switch allows selection of  
either the balanced or unbalanced inputs.  
Input leads should be connected to one  
type of input only i.e. do not connect to  
both the unbalanced and balanced inputs  
at one time.  
PRODUCT SUPPLIED WITHOUT  
MAINS PLUG  
FRONT PANEL  
If your unit comes with a 3-core cable but  
without a plug, make certain LIVE and  
NEUTRAL leads are connected correctly to  
your plug terminals. Check that the terminals  
are screwed down firmly and no loose  
strands of wire are present.  
1. POWER ON INDICATOR  
The red LED indicator behind the  
smoked panel on the front panel will  
illuminate when the power is turned on.  
5. MAINS ON/OFF ROCKER SWITCH  
Depress this switch to the right turn  
power ON. As mute relay circuitry is  
employed in the 200P, full output is muted  
for 1 to 2 second after the power switch is  
actuated.. Depress this switch to the left  
(0) to turn the 200P off at which time the  
IMPORTANT : The wires of the mains/line  
lead in this unit are coloured in  
accordance with the following code :  
REAR PANEL  
2. UNBALANCED INPUT SOCKETS  
These are high quality gold plated  
sockets which are highly conductive,  
corrosion resistant, and provide less  
potential for corrosion induced distortion.  
Inputs are clearly marked Left and Right.  
Care should be taken to maintain  
channel integrity. Refer to section  
SPECIFICATIONS for detail on input  
sensitivity and impedance's.  
power  
amplifier  
outputs  
will  
be  
disconnected.  
BROWN  
LIVE  
BLUE  
GREEN/YELLOW  
NEUTRAL  
EARTH/GROUND  
I
0
=
=
ON  
OFF  
As the wire colours in the mains lead of this  
unit may not correspond exactly with those  
coloured markings on the terminals of your  
plug proceed as follows:  
-
The wire which is coloured BLUE must  
be connected to the terminal which is  
marked with the letter N, or colour coded  
BLUE or BLACK.  
The wire which is coloured BROWN must  
be connected to the terminal which is  
marked with the letter P or L, or colour  
coded BROWN or RED.  
3. BALANCED INPUT SOCKETS  
6. MAINS/LINE INPUT RECEPTACLE &  
FUSE HOLDER  
The 200P feature directly driven  
balanced inputs. The use of good quality  
balanced line cable into the balanced  
input cause the input signal to be  
relatively immune to noise and external  
effects caused by the use of long  
interconnect cables, helps reduce hum  
This receptacle accepts the female end  
of the mains power cord. For more  
-
information  
regarding  
MAINS/LINE  
VOLTAGE and connection see the  
relevant sections.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Located in a small drawer below the  
MAINS/LINE RECEPTACLE is the  
MAINS/LINE FUSE. The drawer can only  
be opened when the mains/line cord is  
removed See the relevant section for  
more details on replacement fuses.  
9. MAINS VOLTAGE / FUSE LABEL  
PROCEDURES  
See relevant section on page 6.  
NOTE : You will also find on the rear panel  
written information and relevant precautions.  
Read and observe the information to ensure  
your safety and trouble free operation from  
your Perreaux 200P.  
Position all the separate components of your  
system close enough to your 200P to avoid  
having to stretch or extend any of the  
interconnect cables. Always make left and  
right channel connections while viewing the  
equipment you are connecting from the front.  
This will help ensure channel continuity  
throughout your system. Avoid errors by  
7. LOUDSPEAKER OUTPUT TERMINALS  
The 200P is equipped with two double  
sets of output terminals per channel to  
enable easy hook-up for bi-wiring of  
loudspeakers or additional loudspeakers.  
These are high quality gold plated  
CONNECTIONS  
adopting  
a
systematic approach when  
Connect your loudspeakers and preamplifier  
to the 200P by following the numbered code  
on page 3 & 4.  
connecting your system together. Make all  
connections logically and carefully.  
terminals.  
marked and colour coded RED Positive  
(+) and BLACK Negative (-). This  
All terminals are clearly  
Note :  
Always switch off your 200P and  
Follow the sequence given in the next  
ensure that the volume control on your  
preamplifier is set to zero before making any  
connections or alterations.  
section, INSTALLATION  
&
OPERATION  
polarity must be strictly observed when  
connecting up loudspeakers, i.e. positive  
terminal of the 200P to the positive  
terminal of the loudspeaker. negative  
terminal of the 200P to the negative  
PROCEDURES. This section incorporates  
all the information in the various areas of this  
manual to assist installation.  
A recommended sequence of connection is  
as follows :  
When connecting the 200P to auxiliary  
equipment terminate the interconnect cables  
with a red plug for the right channel and  
white, black or blue for the left channel.  
Terminate speaker cables using red for  
positive (+) and black, white or blue for  
negative (-).  
terminal of the loudspeaker.  
Good  
quality, preferably gold plated spade or  
banana type terminals are recommended  
together with a high quality loudspeaker  
cable.  
-
-
Connect your loudspeakers to the output  
terminals (7) of the 200P. Be careful to  
maintain channel integrity, i.e. left to left,  
right to right, and phase integrity, positive  
(+) to positive (+), and negative (-) to  
negative (-).  
With the power switch (5) turned off,  
connect the output from your preamplifier  
to the 200P input sockets  
The loudspeaker leads, for both left and  
right channels should be cut to equal  
lengths and be as short as possible. This  
is to maintain uniform resistance at the  
lowest possible level. If the installation  
demands that the 200P be closer to one  
loudspeaker than the other, avoid neatly  
coiling any excess loudspeaker cable as  
this can create inductance and may  
affect high frequency signals. Always  
ensure connections are clean, firm and  
tight.  
These are the most commonly accepted  
colour  
coding  
combinations  
in  
use  
internationally to help maintain channel and  
phase integrity (i.e. left to left, right to right,  
positive to positive, and negative to negative).  
After making all the connections, lay the  
leads and cables out in such a way so that  
loudspeaker leads are well away from the  
interconnect cables, and both are well  
separated from mains/line power cables.  
(2 or 3). Ensure the position of the input  
configuration switch (4) is set for the type  
of interconnect cable being used i.e.  
balanced or unbalanced.  
-
Try to keep all inter-linking cables and  
loudspeaker leads as far apart as  
possible and well away from all  
mains/line cables.  
8. SERIAL NUMBER  
See relevant section on page 6.  
INSTALLATION AND OPERATION  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
-
-
Check that the volume control on your  
preamplifier or source component is set  
to zero then turn on the preamplifier.  
temperature around the 200P to exceed  
40º Celsius (105º Fahrenheit.)  
mains/line supply.  
Any doubts or  
suspicions should be conveyed to your  
Perreaux dealer. RF interference can  
cause serious loudspeaker damage.  
-
Check the mains/line voltage stated on  
the rear panel of your .200P Supply  
voltage must be within 5% +/- of the  
stated voltage. (See relevant section  
MAINS-/LINE VOLTAGE )  
Connect the female end of the 200P  
mains/line cord to the mains/line input  
receptacle (6). Plug the male end into the  
closest available power point and switch  
on the mains/line power.  
-
-
Always turn your Perreaux 200P on last  
and off first making sure the volume  
control of the preamplifier is set to zero in  
both cases.  
This will eliminate the  
possibility of damage to loudspeakers or  
fuses due to switching transients.  
-
-
-
-
Connect all your hi-fi equipment to the  
same mains/line source to avoid possible  
earthing problems.  
-
-
Switch the 200P mains power switch (5)  
to the ON "I " position and listen to each  
speaker in turn for any undesirable  
humming or buzzing noises.  
Always switch off the 200P and zero the  
volume control on your preamplifier  
Do not change the fuse to any type or  
rating other than that indicated on the  
rear panel or owners manual.  
before  
making  
any  
connection  
Without programme source material  
slowly increase the volume on the  
preamplifier listening for undesirable  
noises. A certain amount of hiss may  
become apparent as the gain of the  
preamplifier is increased, this is normal.  
alterations.  
-
-
Make all connections logically and care-  
fully, outputs first then inputs, checking  
that you are maintaining channel integrity.  
Always  
ensure  
your  
200P  
is  
disconnected from the mains/line supply  
if changing the mains/line fuse.  
Keep all inter-linking cables and  
loudspeaker leads as far apart as  
possible and well away from all  
mains/line cables.  
Do not drive the inputs with a voltage  
source greater than that which is required  
to drive the 200P to its maximum  
dynamic output.  
If problems occur, utilise the various fault  
finding chapters in this manual, or consult  
your Perreaux dealer. Otherwise your  
installation is now complete, and ready for  
you to sit back and enjoy.  
-
-
-
-
-
Do not run the outputs in series or  
parallel.  
MAINS/LINE VOLTAGE  
INSTALLATION AND OPERATION  
PRECAUTIONS  
-
Do not earth any positive terminal or  
connect the input to the output earth.  
It is important that the 200P be operated from  
the correct mains/line voltage. The unit is  
factory set for the voltage applicable to the  
original country of destination. The correct  
operating voltage is indicated by the MAINS  
VOLTAGE / FUSE RATING LABEL (9) on  
the rear panel .The 200P will operate  
satisfactorily within a voltage variation of up  
to +/- 5% either side of that voltage at which  
the unit has been set.  
Leave the top and bottom of the clear at  
all times allowing adequate airflow  
around the sides of the unit. Do not site  
this unit directly on carpet or other soft  
Do not connect the output of the 200P to  
any other voltage source.  
surfaces.  
Do not place auxiliary  
Do not run the outputs into the inputs of  
the 200P.  
equipment directly on top of the 200P.  
-
-
Always operate in a horizontal position.  
Operation of the 200P in the vicinity of a  
strong radio frequency (RF) source  
should be countered by RF filtering on all  
inputs and outputs including the  
Install away from excessive heat and  
moisture. Do not allow the ambient  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
If you require the voltage setting to be  
altered, e.g. relocation to another area, city or  
country, or extraordinarily high or low  
voltages, contact your Perreaux dealer. This  
modification must only be performed by  
qualified service personnel.  
Fuse Rating -3AG Normal Acting 6 Amp  
INPUT IMPEDANCE  
Balanced 3.3k  
Unbalanced 22kΩ  
SERIAL NUMBER  
DYNAMIC HEADROOM  
1.9dB  
CURRENT OUTPUT  
All Perreaux units are allocated a unique  
serial number which are recorded at the  
factory against build details. If you should  
require information about your unit, providing  
the serial number will help achieve a prompt  
reply.Keep a copy of all your serial numbers  
in a safe place. The ability to identify and  
prove ownership can be very useful.  
Note: Always ensure the unit is disconnected  
from the Mains/Line supply before any covers  
are removed.  
24 Amperes peak per channel  
DRIVER STAGE  
Class A  
MAINS/LINE FUSE  
OUTPUT STAGE  
Class A / AB  
The Perreaux 200P is equipped with a user  
serviceable mains/line fuse.  
Above the  
SPECIFICATIONS  
mains/line cord is the mains/line fuse holder.  
In the unlikely event of fuse failure always  
replace with the same type and value fuse.  
Remember, fuses do not usually blow without  
a reason. Any doubts about fuse failure  
should be conveyed directly to your Perreaux  
dealer.  
DIMENSIONS (not including handles and  
terminals)  
Tested at 120 / 220 / 230 / 240V ac  
mains voltage after initial 10 minute warm  
up period  
HEIGHT x WIDTH x DEPTH  
88mm x 482mm x 460mm  
3.5" x 19.0" x 18.1"  
POWER OUTPUT  
200 watts RMS per channel continuous  
both channels driven into 8from 20Hz  
to 20kHz at no more than 0.02% THD  
The fuse ratings are:  
100-125V 2SB SLOW BLOW 8A  
Continuous  
NETT WEIGHT  
17.0kg (37.5lb)  
200-250V 2SB SLOW BLOW 6A  
Continuous  
Note: Always ensure your 200P is  
disconnected from the Mains/Line supply  
before attempting to change the Mains/Line  
fuse.  
300 watts RMS into 4Ω  
FREQUENCY RESPONSE  
± 0.25dB from 20Hz to 20kHz  
TOTAL HARMONIC DISTORTION  
0.02% THD worst case prior to clipping  
0.004% THD @ 1KHz  
RAIL FUSES  
HUM, NOISE  
-95dB unweighted referenced to rated  
output  
The Perreaux 200P has 4 internal fuses for  
amplifier protection. In the unlikely event of  
internal fuse failure consult your Perreaux  
dealer. The internal fuses are not user  
serviceable and only authorised personnel  
may replace the internal fuses.  
INPUT SENSITIVITY  
Balanced 0.6V RMS  
Unbalanced 1.2V RMS  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peg Perego Stroller P3 User Manual
Pelican Home Safety Product m6 2390 led 3w User Manual
Pentax Camera Flash 200FG User Manual
Philips TV Mount SQM6375 27 User Manual
Philips TV VCR Combo 14PV284 User Manual
Pinnacle Design TV Video Accessories TV73003 User Manual
Pioneer Car Stereo System P4200UB User Manual
Polk Audio Speaker PSW111 User Manual
Poulan Lawn Mower PRGT22H50C User Manual
Powermate Portable Generator PC049650417 User Manual