Pentair Swimming Pool Filter Quad DE User Manual

Quad D.E.®  
D.E. Cartridge Style Filter  
Installation and User's Guide  
IMPORTANT SAFETY INSTRUCTIONS  
READ AND FOLLOW ALL INSTRUCTIONS  
SAVE THESE INSTRUCTIONS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i
Table of Contents  
Important Safety Precautions..............................................................................................ii  
Section 1: Introduction .....................................................................................................1  
Quad D.E.® Filter Overview .....................................................................................1  
General Features.....................................................................................................2  
Section 2: Installation .......................................................................................................3  
Installing the Quad D.E.® Filter ................................................................................3  
General Information .................................................................................................3  
Section 3: Filter Operation ...............................................................................................5  
Filter Operation Information .....................................................................................5  
Filter Clamp Installation ...........................................................................................6  
Section 4: System Restart Instructions ..........................................................................7  
Preparing Diatomite .................................................................................................8  
Coating the Filter Elements with D.E. ......................................................................8  
Section 5: Maintenance .....................................................................................................9  
Manually Cleaning the Quad D.E.® Filter .................................................................9  
Replacing Filter Cartridge Style Elements...............................................................10  
Cleaning the Filter using a Separation Tank System ...............................................10  
Cleaning Filter Elements..........................................................................................11  
Cleaning the Internal Air Bleed Tube ........................................................................12  
Cleaning the High Flow™ Manual Air Relief Valve ..................................................12  
Section 6: Troubleshooting ..............................................................................................13  
Section 7: Replacement Parts ..........................................................................................15  
Section 8: Technical Data..................................................................................................16  
Head Loss Comparison Curves ..............................................................................16  
Flow Rate information ..............................................................................................16  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ii  
IMPORTANT SAFETY PRECAUTIONS  
Body  
Important Notice:  
This guide provides installation and operation instructions for the Quad D.E.® Filter.  
Consult Pentair Water Pool and Spa® with any questions regarding this equipment.  
Attention Installer: This guide contains important information about the installation, operation and safe use of  
this product. This information should be given to the owner and/or operator of this equipment after installation or left on  
or near the filter.  
Attention User: This manual contains important information that will help you in operating and maintaining this  
filter. Please retain it for future reference.  
WARNING Before installing this product, read and follow all warning notices and instructions which are  
included. Failure to follow safety warnings and instructions can result in severe injury, death,  
or property damage. Call (800) 831-7133 for additional free copies of these instructions.  
Consumer Information and Safety  
The Quad D.E. Filters are designed and manufactured to provide many years of safe and reliable service when installed,  
operated and maintained according to the information in this manual and the installation codes referred to in later  
sections. Throughout the manual, safety warnings and cautions are identified by the “ “ symbol. Be sure to read and  
comply with all of the warnings and cautions.  
WARNING Do not operate the filter until you have read and understand clearly all the operating instructions  
and warning messages for all equipment that is a part of the pool circulating system. The  
following instructions are intended as a guide for initially operating the filter in a general pool  
installation, however each installation may have unique conditions where the starting procedure  
could be different. Failure to follow all operating instructions and warning messages can result  
in severe injury, death, or property damage.  
WARNING THIS FILTER OPERATES UNDER HIGH PRESSURE.  
When any part of the circulating system, (e.g., clamp, pump, filter, valve(s), etc.), is serviced, air  
can enter the system and become pressurized. Pressurized air can cause the lid to be blown off  
which can result in severe injury, death, or property damage. To avoid this potential hazard, follow  
these instructions:  
1. Beforerepositioningvalve(s)andbeforebeginningtheassembly, disassembly, oradjustment  
of the clamp or any other service of the circulating system: (A) Turn the pump OFF and shut  
OFF any automatic controls to ensure the system is NOT inadvertently started during the  
servicing;(B)opentheHighFlowmanualairreliefvalve;(C)waituntilallpressureisrelieved.  
2. Whenever installing the filter clamp FOLLOW THE FILTER CLAMP INSTALLATION  
INSTRUCTIONS EXACTLY.  
3. Once service on the circulating system is complete FOLLOW SYSTEM RESTART  
INSTRUCTIONS EXACTLY.  
4. Maintain circulation system properly. Replace worn or damaged parts immediately,  
(e.g., clamp, pressure gauge, valve(s), o-rings, etc).  
5. Be sure that the filter is properly mounted and positioned according to instructions provided.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iii  
IMPORTANT SAFETY PRECAUTIONS (continued)  
WARNING Due to the potential risk that can be involved it is recommended that the pressure test be kept to the  
minimum time required by the local code. Do not allow people to work around the system when the  
circulation system is under pressure test. Post appropriate warning signs and establish a barrier  
around the pressurized equipment. If the equipment is located in an equipment room, lock the door  
and post a warning sign.  
Never attempt to adjust any closures or lids or attempt to remove or tighten bolts when the system is  
pressurized. These actions can result in a separation or failure of system components. This  
instantaneous release of energy can cause components to be accelerated to high velocities and to  
travel far distances. These components could cause severe personal injury or death if they were to  
strike a person.  
WARNING Risk of electrical shock or electrocution.  
This pool filter must be installed by a qualified pool serviceman in accordance with the National  
Electrical Code and all applicable local codes and ordinances.  
Always disconnect power to the pool equipment at the circuit breaker before servicing any of the  
equipment. Ensure that the disconnected circuit is locked out or properly tagged so that it cannot be  
switched on while you are working on the pool equipment. Failure to do so could result in serious injury  
or death to serviceman, pool users or others due to electric shock.  
Position the filter and the air relief valve to safely direct water drainage and purged air or water. Water  
discharged from an improperly positioned filter or valve can create an electrical hazard that can cause  
severe personal injury as well as damage property.  
WARNING To reduce the risk of injury, do not permit children to use this product unless they are closely  
supervised at all times.  
CAUTION — This filter is for use with permanently installed pools and may also be used with hot tubs and spas if  
so marked. Do not use with storable pools. A permanently installed pool is constructed in or on the  
ground or in a building such that it cannot be readily disassembled for storage. A storable pool is  
constructed so that it may be readily disassembled for storage and reassembled to its original  
integrity.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iv  
IMPORTANT SAFETY PRECAUTIONS (continued)  
General Installation Information  
The following information should be read carefully since it outlines the proper manner of care and operation for your  
filter system. You can expect maximum efficiency and life from your filtration system by following these instructions and  
taking the necessary preventative care.  
• Have a trained pool professional perform all pressure tests.  
• Do not connect the system to a high pressure or city water system.  
• Trapped air in the system can create a hazardous condition. BE SURE to purge all air from the  
system before operating or testing equipment.  
• DO NOT pressure test with compressed air!  
• Check local codes for restrictions on backwash to waste piping, separation tank requirements and  
spent D.E. disposal requirements.  
• DO NOT use more than the recommended amount of D.E. in your filter. To do so can cause a buildup  
of D.E. and “bridging” between the elements which will plug the filter.  
• Piping must conform to local/state plumbing and sanitary codes.  
• Support piping independently to prevent strains on filter or valve.  
• Fittings restrict flow; for best efficiency, use the fewest possible fittings.  
• A check valve installed ahead of the filter inlet will prevent contaminants from draining back into the  
pool.  
• A check valve installed between the filter and heater will prevent hot water from backing up into the  
filter and deforming the internal components.  
• To allow recirculation during precoat, (if precoat pot is used), install a recirculation line with shut-off  
between pad return line and pump suction.  
• All wiring, grounding and bonding of associated equipment must meet local and/or National Electrical  
Code standards.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
Section 1  
Introduction  
Quad D.E.® Cartridge Style Filter Overview  
The crystal clarity of D.E. with cartridge convenience  
Diatomaceous earth (D.E.) filters have always been recognized for providing the cleanest pool water. And  
cartridge filters are popular for their convenience and easy-cleaning features. Now, Pentair has found a way  
to bring you the best of both.  
The new Quad D.E. Cartridge Filter features four easily accessible and removable cartridges. When water  
passes through these cartridges, microscopic impurities like dirt, algae, and some forms of bacteria are filtered  
out, giving you water that really sparkles.  
The four-cartridge design greatly increases the filter’s internal surface area, meaning much greater cleaning  
capacity per cycle without an increase in canister size. And cleaning couldn’t be easier. In fact, you have  
three options...backwash and recharge like a traditional D.E. filter, remove and rinse off the cartridges, or  
simply remove the lid, leave the cartridges in place, open the drain plug, and rinse.  
You’ll even save money – water flows through the Quad D.E. so efficiently that with the correct pump you  
use less energy.  
The highest water clarity with the lowest amount of fuss  
The Quad D.E. combination of diatomaceous earth (D.E.) in a convenient cartridge design means better  
performance and longer periods between cleanings. Because D.E. removes the tiniest of contaminants –  
particles as small as five microns – you can count on clean, crystal-clear water for years to come.  
Quad D.E.® Filter  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
General Features  
Four large-capacity cartridges provide maximum filter surface area for greater dirt-trapping capacity and  
longer periods between cleanings.  
Unique internal flow path ensures optimum filtration and backwashing efficiency.  
Chemical resistant, fiberglass reinforced polypropylene tank for exceptional strength and long life.  
Tension Control™ clamp for secure closure.  
2” plumbing connections for simple and secure maximum flow.  
Conveniently located 2" drain for easy and efficient clean-out and 100% draining.  
Additional Features:  
High Flow™ manual air relief valve and continuous internal air relief work together to maintain efficient  
filtration and prevent over-pressurization.  
Durable 8 oz. polypropylene cartridge media has superslick surfaces, making them easier to clean than  
conventional cartridge filters.  
Easily removable cartridge elements to simplify maintenance and save you time.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Section 2  
Installation  
The following general information describes how to install the Quad D.E.® Filter.  
Note: Before installing this product, read and follow all warning notices and instructions starting on page ii.  
Installing the Quad D.E.® Filter  
Only a qualified service person should install the Quad D.E. Filter.  
General Information  
1. The filter should be mounted on a level concrete slab. Position the filter so that instructions, warnings and  
the pressure gauge are visible to the operator. It also should be positioned so that the piping connections,  
control valve and drain port are convenient and accessible for servicing and winterizing.  
2. Install electrical controls (e.g., on/off switches, timers, control systems, etc.) at least five (5) feet from the  
filter. This will allow you enough room to stand clear of the filter during system start up.  
3. Allow sufficient clearance around the filter to permit visual verification that the clamp is properly installed  
around the tank flanges, see Figure 1.  
a. Tap the clamp with a mallet or similar tool to ensure uniform loading during clamp tightening.  
4. Allow sufficient space above the filter to remove the filter lid for cleaning and servicing. This distance will  
vary with the model of filter you are using. See Table 1 for the required vertical clearance.  
WARNING Risk of electrical shock or electrocution.  
Position the filter and High Flow™ manual air relief valve to safely direct water drainage and purged  
air or water. Water discharged from an improperly positioned filter or valve can create an electrical  
hazard that can cause severe personal injury as well as damage property.  
5. Position the filter to safely direct water drainage. Rotate the High Flow™ manual air relief valve to safely  
direct purged air or water. Water discharged from an improperly positioned filter or valve can create an  
electrical hazard as well as damage property.  
CAUTION The Pentair Quad D.E. filter has a different water flow pattern than all other Pentair D.E. filters. When  
plumbing the filter with a backwash valve, one of the following valves, listed below, must be used. Failure  
to use the correct backwash valve could damage the filter elements and void the warranty.  
6. Your filter requires one of the following Pentair Water Pool and Spa accessories which must be purchased  
separately:  
a. P/N 261055 - 2” Multiport Valve Kit  
b. P/N 261173 - 1½” Multiport Valve Kit  
c. P/N 261050 - 2” HiFlow Valve Kit  
d. P/N 261165 - 2” PVC Slide Valve Kit  
e. P/N 263034 - 2” ABS Slide Valve Kit  
Table 1.  
Vertical  
Model  
P/N  
Size  
ClearanceReq. NSF  
QUAD60  
QUAD80  
188592  
188593  
60 sq. ft.  
80 sq. ft.  
100 sq. ft.  
62 in.  
68 in.  
74 in.  
yes  
yes  
yes  
Figure 1.  
QUAD100 188594  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
General Information, cont.’d.  
7. Make all plumbing connections in accordance with local plumbing and building codes. Check local codes  
for restrictions on backwash to waste piping, separation tank requirements and spent D.E. disposal  
requirements.  
8. Filter plumbing connections are provided with an o-ring seal. To avoid damage to the o-rings, use only a  
silicone base lubricant on the o-rings. Do not use pipe joint compound, glue or solvent on the bulkhead  
connections.  
WARNING THIS FILTER OPERATES UNDER HIGH PRESSURE.  
Never subject this filter to pressure in excess of the maximum working pressure - even when conducting  
hydrostatic pressure tests. Pressures above the maximum working p.s.i. pressure can cause the lid  
to be blown off, which can result in severe injury, death or property damage.  
9. The maximum working pressure of this filter is 50 psi. Never subject this filter to pressure in excess of this  
amount - even when conducting hydrostatic pressure tests. Pressures above 50 psi can cause the lid to be  
blown off, which can result in severe injury, death or property damage.  
When performing hydrostatic pressure tests or when testing for external leaks of the completed filtration and  
plumbing system, ensure that the maximum pressure that the filtration system will be subjected to DOES  
NOT EXCEED THE MAXIMUM WORKING PRESSURE OF ANY OF THE COMPONENTS CONTAINED  
WITHIN THE SYSTEM. In most cases, the maximum working pressure will be stated on each component of  
the system.  
If doubt exists as to the pressure to which the system will be subjected, install an ASME approved automatic  
Pressure Relief or Pressure Regulator in the circulation system for the lowest working pressure of any of the  
components in the system.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
Section 3  
Filter Operation  
This section describes how the Quad D.E.® operates.  
General Filter Information  
WARNING THIS FILTER OPERATES UNDER HIGH PRESSURE. When any part of the circulating system,  
(e.g., clamp, pump, filter, valve(s), etc.), is serviced, air can enter the system and become pressurized.  
Pressurized air can cause the lid to be blown off which can result in severe injury, death, or property  
damage. To avoid this potential hazard, follow these instructions:  
1. Before repositioning valve(s) and before beginning the assembly, disassembly, or adjustment  
of the clamp or any other service of the circulating system: (A) Turn the pump OFF and shut OFF  
any automatic controls to ensure the system is NOT inadvertently started during the servicing;  
(B) open the High Flow™ manual air relief valve; (C) wait until all pressure is relieved.  
2. Whenever installing the filter clamp FOLLOW THE FILTER CLAMP INSTALLATION  
INSTRUCTIONS EXACTLY.  
3. Once service on the circulating system is complete FOLLOW SYSTEM RESTART  
INSTRUCTIONS EXACTLY.  
4. Maintain circulation system properly. Replace worn or damaged parts immediately, (e.g., clamp,  
pressure gauge, valve(s), o-rings, etc).  
5. Be sure that the filter is properly mounted and positioned according to instructions provided.  
1. This filter operates under pressure. When clamped properly and operated without air in the water system,  
this filter will operate in a safe manner.  
2. The maximum working pressure of this filter is 50 psi. Never subject this filter to pressure in excess of this  
amount - even when conducting hydrostatic pressure tests. Pressures above 50 psi can cause the lid to be  
blown off, which can result in severe injury, death or property damage.  
When performing hydrostatic pressure tests or when testing for external leaks of the completed filtration  
and plumbing system, ensure that the Maximum Pressure that the filtration system will be subjected to  
DOES NOT EXCEED THE MAXIMUM WORKING PRESSURE OF ANY OF THE COMPONENTS  
CONTAINED WITHIN THE SYSTEM. In most cases, the maximum working pressure will be stated on  
each component of the system.  
Ifdoubt existsastothe pressure towhichthe system will be subjected, install anASME approvedautomatic  
Pressure Relief or Pressure Regulator in the circulation system for the lowest working pressure of any of  
the components in the system.  
3. The pressure gauge is the primary indicator of how the filter is operating. Maintain your pressure gauge  
in good working order.  
4. Never operate filter in excess of three (3) minutes without use of diatomaceous earth. Diatomaceous earth  
is the substance that filters the water, the filter cloth merely supports the diatomaceous earth. Operating  
without diatomaceous earth will damage filter elements and shorten filtering cycles.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
Clamp Installation  
These instructions MUST BE FOLLOWED EXACTLY to prevent the lid from blowing off during system  
restart or later operation.  
1. Perform the following steps before working on any part of the circulating system, e.g., clamp, pump, filter,  
valve(s), etc.  
a. Turn the pump off and shut off any automatic controls to ensure that the system is not inadvertently  
started during servicing.  
b. OpentheHighFlowmanualairreliefvalveuntilitsnapsintothefullopenposition(thisonlyrequires  
a quarter turn counter clockwise).  
c. Wait until all pressure is relieved. Never attempt to assemble, disassemble or adjust the filter  
clamp while there is any pressure in the filter.  
2. Be certain the o-ring is in position in the lower tank half. Press the filter lid over the lower tank half  
sandwiching the o-ring in between.  
3. Holding the ends of the filter clamp apart, position the center segment of the filter clamp over both upper  
and lower tank flanges. Bring the ends of the filter clamp together, while inserting the T-bolt into the  
trunnion; see Figure 2.  
4. Using Figure 2 as a guide — place washer (large I.D.) and the tension-indicating spring on the barrel nut.  
Place the second washer (small I.D.) on the T-bolt. Hand-tighten nut. Recheck filter clamp for proper  
seating on tank flanges.  
5. Begin to tighten nut using a 7/8 in. wrench. Then tap around the outside of the filter clamp with a mallet  
(orsimilartool)toensureuniformloadingandproperseatingoftheclamp. Continuetappingandtightening  
until the spring coils touch each other. Do not tighten beyond this point.  
6. Follow the instructions in Section 4; on page 7, SYSTEM RESTART INSTRUCTIONS.  
7. The spring coils should be checked at least once per month to ensure that they continue to touch each other,  
indicating that the clamp is under sufficient tension. If coils fail to touch, repeat Step 5 above.  
Figure 2.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Section 4  
System Restart Instructions  
This section describes how to restart the Quad D.E.® filter system.  
System Restart Instructions  
WARNING THIS FILTER OPERATES UNDER HIGH PRESSURE. When any part of the circulating system,  
(e.g., clamp, pump, filter, valve(s), etc.), is serviced, air can enter the system and become pressurized.  
Pressurized air can cause the lid to be blown off which can result in severe injury, death, or property  
damage. To avoid this potential hazard, follow these instructions:  
1. Open the High Flow™ manual air relief valve until it snaps into the full open position (this only  
requires a quarter turn counter clockwise). Opening this valve rapidly releases air trapped in the filter.  
2. Stand clear of the filter tank, then start the pump.  
3. Close the High Flow™ manual air relief valve after a steady stream of water appears.  
4. The system is not working properly if:  
a. A solid stream of water does not appear within 30 seconds after the pump's inlet basket fills with water.  
b. The pressure gauge indicates pressure before water out-flow appears.  
If either condition exists, shut off the pump immediately, open valves in the water return line to relieve  
pressure, and clean the air relief valve; see Section 3; on page 5, FILTER OPERATION. If the problem  
persists, call Customer Service at (800) 831-7133.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Preparing Diatomite  
Your filter requires diatomaceous earth (D.E. or diatomite) for proper filtration and operation. Your filter  
elements must be precoated with this material in order to protect their surfaces and provide the most efficient  
filtering action. Refer to Table 2 for the proper quantity to use with your filter. We recommend the use of D.E.  
which is sold and labeled for use with swimming pools and spas. These grades of D.E. typically have a  
median particle size of 34 microns, which is ideal for most applications.  
1. The Quad D.E. filters are listed with the appropriate amounts of diatomite to be used to precoat the filter  
elements. A one (1) pound coffee can filled (level) with diatomite is equal to one half pound weight of  
diatomaceous earth. Do not "pack" or compress diatomite into the coffee can.  
2. Mix the required amount of diatomite with sufficient water  
FilterArea  
(sq. ft.)  
Weightof  
D.E.  
No. of 1 lb.  
CoffeeCans  
in a bucket to make a thin, milky mixture.  
60  
80  
6 lbs.  
8 lbs.  
12  
16  
20  
3. Follow the instructions below for COATING THE FILTER  
ELEMENTS to introduce the slurry of diatomite into the filter.  
100  
10 lbs.  
Table 2  
Coating the Filter Elements with Diatomaceous Earth  
CAUTION The following information should be read carefully since it outlines the proper manner of care and  
operation for your filter system. You can expect maximum efficiency and life from your filtration  
system by following these instructions and taking the necessary preventative care.  
1. SlideValve.  
a. Twist to unlock plunger, then raise the handle as far as it will go. Turn handle clockwise to lock lower  
pin in underside of cap.  
2. MultiportValve.  
a. Position valve to FILTER OR VACUUM TO POOL setting. This is your normal flow from the pump  
through the filter to the pool. Open the High Flow™ manual air relief valve on the filter. Proceed with  
Steps 2.b to 2.g, below.  
b. Prepare recommended amount of diatomaceous earth by mixing it with water in a bucket until it is the  
consistency of milk; see above, PREPARING DIATOMITE.  
c. On initial start-up the pump must be primed by filling the hair and lint strainer pot with water. You may  
have to do this several times.  
d. Follow the steps outlined in Section 4; on page 7, SYSTEM RESTART INSTRUCTIONS for system  
start-up.  
e. Introduce the slurry of diatomite from the bucket directly into the top of the skimmer. With the pump  
running and the pool skimmer valve open, pour the mixture directly into the skimmer. The slurry will  
be drawn into the filter.  
f. Your filter is now operational. Note the original starting pressure on the gauge and record it below.  
g. Clean your filter when pressure reads between 10 to 12 psi higher than the original starting pressure.  
Your filter pressure reading will increase as it removes dirt from your pool. However, this build-up of  
pressure will vary due to different bathing loads, temperature, weather conditions, etc.  
h. MY ORIGINAL STARTING PRESSURE IS ______________ psi (pounds per square inch).  
I SHOULD BACKWASH AT _____________ psi.  
NOTE  
If the starting pressure after backwashing the filter or cleaning the elements indicates 4 to 5 psi higher than the normal starting  
pressure, the filter elements must be cleaned. Refer to Step 1; on page 10, CLEANING FILTER ELEMENTS for instructions.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Section 5  
Maintenance  
Cleaning the Quad D.E.® Filter Manually  
1. Turn the pump off, shut off any automatic controls to ensure that the system is not inadvertently started  
duringservicing.  
2. AutomaticskimmershouldhaveVari-Flotrimmervalvesetto100%skimmer.Thiswillcloseoffthemaindrain  
line. If there is a separate skimmer line and main drain line plumbed to the pump, close the main drain valve.  
3. Open the filter High Flow™ manual air relief valve, and the waste drain valve or plug if your system has  
one. Disconnect air relief valve drain hose if installed.  
4. Remove the pump’s hair and lint strainer pot lid and clean the basket. Replace basket and secure lid. Follow  
the instructions provided with your pump.  
5. Never attempt to assemble, disassemble or adjust the filter clamp while there is pressure in the  
filter. Release the tank clamp assembly and remove tank lid.  
6. Ensure the internal air bleed assembly is in place and free of diatomite or debris, see page 12, CLEANING  
THE INTERNAL AIR BLEED TUBE.  
7. Remove top manifold and cartridge style elements separately.  
8. Using a garden hose without a nozzle, direct water spray at cartridge style elements to dislodge and wash  
away accumulated foreign matter. Flush each cartridge inside and out.  
WARNING Please heed all manufacturers' posted instructions, warnings and cautions when using Baquacil® or  
Baqua Clean®.  
NOTE  
SpecialcaremustbetakenwhencleaningfiltercartridgestyleelementsusedinaswimmingpoolorspausingBaquacil® asasanitizer.Because  
ofthewayBaquacil® works,thefilterelementmustbecleanedmorethoroughlyandmorefrequentlythaninachlorinesystem.Ifextremecare  
isnottakentocompletelyremoveallresiduefromthefiltermediaabuildupwilloccur. Thisbuildupwillsignificantlyshortenthelifeofthefilter  
element.  
Baquacil® isamildcoagulantwhichcombinesbacterialcellsaswellasothersmallparticlescontributedbytheenvironment,bathers,etc.into  
particleslargeenoughtobetrappedbythefilter.Incomparisonwithallothertrappedcontaminantsinatypicalpoolorspatheamountofbacterial  
cellsthataredepositedonthefilterisminimal.TheresultingdepositisagraystickyfilmwhichcanonlyberemovedwithBaquaClean®.IfTSP  
or any TSP-type cleaner is used prior to stripping the film, the cleaner and the gray film will combine to form a gum-like substance. Once this  
occurs, the substance cannot be removed from the media and the filter cartridge must be replaced.  
9. Lift bottom manifold out of the tank and flush off any debris.  
10. Direct water spray to wash out the inside of the tank body. Water and debris will drain out through the open  
drain port.  
11. Check gasket around outer lip of bottom plate. Gasket must be firmly and evenly set in place. Do not use  
petroleum base lubricants to avoid damage to the gasket.  
12. Place bottom manifold, 4 cartridge style elements, top manifold and air relief tube in place. Make sure the  
spring and standpipe assembly are retained on the top manifold. Ensure the air relief tube stays in an upright  
position. This is essential for the maximum air removal from inside the tank.  
13. Be certain the o-ring is in position in the lower tank half. Press the filter lid over the lower tank half and  
sandwich the o-ring in between.  
14. Replacetanktopandcarefullyfollowinstructionsonpage6,CLAMPINSTALLATIONINSTRUCTIONS.  
15. Replace drain plug and reinstall air relief valve drain hose if used.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
Replacing Filter Cartridge Style Elements  
Filter cartridge style element life will vary with pool conditions such as bather load, wind, dust, etc.  
You can expect an average cartridge life of 3 years under normal conditions.  
1. To replace cartridge style elements follow steps in Section 5; on page 9, CLEANING FILTER  
MANUALLY, eliminating step 8.  
Cleaning your Filter using a System with a Separation Tank  
1. Before working on any part of the circulating system, clamp, pump, filter, valve(s), etc., perform the  
followingsteps.  
a. Turn the entire pool/spa system off to ensure that the system is not inadvertently started during  
servicing.  
b. Open the High Flow™ manual air relief valve.  
c. Wait until all pressure is relieved. Never attempt to assemble, disassemble or adjust the filter  
clamp while there is pressure in the filter.  
2. Turn skimmer to full skim position and close main drain line.  
3. Remove pump lid and clean basket. Replace basket and secure lid.  
4. Valve Procedures.  
a. Slide Valve.  
(1) Push the handle on the valve down with slight twisting motion as far as it will go. Lock upper pin in  
cap. Open High Flow™ manual air relief valve on filter. Proceed with steps b(1) to b(9) on page 11.  
(2) Open the High Flow™ manual air relief valve until it snaps into the full open position  
(this only requires a quarter turn counter-clockwise). Opening this valve rapidly releases  
air trapped in the filter.  
(3) Stand clear of the filter tank, then start the pump.  
(4) Close the High Flow™ manual air relief valve after a steady stream of water appears.  
(5) When water flows clear in sight glass or discharge line, shut off pump.  
(6) Position the Slide valve to the normal FILTER setting by raising the handle and twisting it to the  
lockedposition.  
(7) OpenHighFlowmanualairreliefvalveontopofseparationtank, waitforwatertostopdraining  
from air relief.  
(8) Loosen Separation Tank clamp and lift off Separation Tank lid.  
(9) Remove bag and dispose of diatomite in trash can. Replace clean bag and set bag in seat (curved  
portion of Separation Tank). Make sure the top of the bag is below the inlet to prevent earth from  
going back into pool, one double bag is furnished with Separation Tank.  
NOTE  
Filter waste and diatomite are trapped by the heavy-duty double lined Separation Tank bag. Contents are to be placed in  
a waste or trash container, clean the bag and re-insert in the Separation Tank. DO NOT LEAVE THE SEPARATION TANK  
BAG EXPOSED IN THE SUN. The manufacturer cannot assume any responsibility for torn, or damaged bags, if left in the  
sun to dry.  
(10) Replace Separation Tank lid and secure Separation Tank lid clamp. Follow instructions on page 6,  
CLAMP INSTALLATION INSTRUCTIONS.  
(11) Leave valve in normal FILTER position.  
(12) FollowinstructionsinSection4;on page7, SYSTEMRESTARTINSTRUCTIONStostartupfilter.  
(13) Introduce the recommended amount of diatomite per Section 4; on page 8, COATING THE  
FILTER ELEMENTS. Your filter is now in operation.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
Cleaning your Filter using a System with a Separation Tank, cont’d.  
b. Multiport Rotary Valve.  
After completing Steps 1 to 3 of this section; on page 10, perform the following steps:  
(1) Position the valve to the BACKWASH setting.  
(2) Open the High Flow™ manual air relief valve until it snaps into the full open position  
(this only requires a quarter turn counter-clockwise). Opening this valve rapidly releases  
air trapped in the filter.  
(3) Stand clear of the filter tank, then start the pump.  
(4) Close the High Flow™ manual air relief valve after a steady stream of water appears and run  
in the BACKWASH mode for 1 minute.  
(5) Stop the pump, set the filter valve to FILTER and run for 20 seconds, then stop the pump.  
(6) Repeat the BACKWASH/FILTER cycle 3 times.  
(7) When the sight glass shows a clear flow of water, shut off the pump.  
(8) Position Multiport Rotary valve to the CLOSED setting.  
(9) Follow section 4.a – Slide Valve on page 10.  
Cleaning Filter Elements  
For a more thorough cleaning of the individual elements, perform the following steps:  
1. Cleaning with water:  
a. Using a garden hose, thoroughly flush off all contaminated diatomite from the filter element surfaces.  
2. Cleaningwithmuriaticacid:  
WARNING Working with muriatic acid can be dangerous. When cleaning elements always wear rubber gloves  
and eye protection. Add acid to water, do not add water to acid. Splashing or spilling acid can cause  
severe personal injury and/or property damage.  
a. A stiffening of the fabric caused by mineral deposits is usually referred to as "liming up". It usually is  
due to deposits of either magnesium or calcium or both. Removal of these deposits may be  
accomplished by soaking the filter elements in six (6) parts water to one (1) part hydrochloric acid  
(muriatic acid).  
b. Wear rubber gloves and eye protection when mixing the solution, and handling or rinsing the filter  
elements.  
c. Soak for at least four (4) hours in a plastic tub or pail.  
d. Rinse filter elements thoroughly in tap water.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
Cleaning the Internal Air Bleed Tube  
1. Rinse the air bleed tube with water to clean away built-up debris. Normally, this is all that is necessary to  
properly clean the tube.  
Cleaning the High FlowManual Air Relief Valve  
1. Turn the pump off and shut off any automatic controls to ensure that the system is not inadvertently  
started during servicing.  
2. OPEN THE HIGH FLOW™ MANUAL AIR RELIEF VALVE UNTIL IT SNAPS INTO THE  
FULL OPEN POSITION, THEN WAIT UNTIL ALL PRESSURE IS RELIEVED.  
3. With the High Flow™ manual relief valve attached to the filter tank, pull out the locking tabs and remove  
the valve stem and cover assembly with a counter-clockwise and lifting motion, see Figure 3.  
4. Clean debris from the valve stem and body. Ensure that the filter tank's air passage is open by inserting a  
5/16 in. drill bit through the valve body. Ensure that the o-rings are in good condition, properly positioned,  
and lubricated with a silicone base lubricant.  
5. Reinstall the valve stem and cover assembly with a downward and clockwise motion until it snaps into  
position.  
Figure 3.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
Section 6  
Troubleshooting  
Use the following troubleshooting information to resolve possible problems with your Quad D.E.® Filter.  
WARNING THIS FILTER OPERATES UNDER HIGH PRESSURE.  
When any part of the circulating system, (e.g., clamp, pump, filter, valve(s), etc.), is serviced, air can  
enter the system and become pressurized. Pressurized air can cause the lid to be blown off which  
can result in severe injury, death, or property damage.  
1. If you are not familiar with your pool filtering system and/or heater:  
a. Do NOT attempt to adjust or service without consulting your dealer, or a qualified pool  
technician.  
b. Read the entire Installation & User’s Guide before attempting to use, service or adjust the  
pool filtering system or heater.  
Note: Turn off power to unit prior to attempting service or repair.  
Problems and Corrective Actions  
Problem  
CorrectiveAction  
AIR ENTERING THE FILTER  
Correct any conditions in your filtration system  
that allow air to enter the system.  
a. Low water level in pool or spa - skimmer is  
starving for water with pump running.  
Add water to pool or spa.  
b. Air bubbles or low water level in pump hair  
and lint pot are caused by the following factors:  
(1) Low water level.  
(2) Cloggedskimmerbasket.  
(3) Split suction cleaner hose.  
(4) Leak in pump hair and lint pot lid.  
(5) Leak in pump suction line.  
c. Air bubbles coming out of water return lines into  
pool or spa with pump running, see steps a-b,  
above.  
d. AirisdischargedfromtheHighFlowmanualair  
relief valve on top of the filter when the valve is  
opened with the pump running, see steps a-b  
above.  
LIMING-UP  
A stiffening of the fabric caused by mineral deposits. a. Removal of these may be accomplished by  
It usually is due to deposits of either magnesium or  
calcium or both.  
soaking the grids in six (6) parts water to  
one (1) part hydrochloric acid (muriatic acid).  
b. Refer to page 10, Cleaning Filter Elements  
with muriatic acid for cleaning instructions.  
CLOUD OF DIRT  
A brief "cloud" of dirt may appear immediately when a. This is a characteristic of diatomite filters.  
the filter starts.  
SHORT FILTER RUNS  
Until the water initially put into the pool has been  
completely filtered, short filter runs are normal.  
a. Plaster dust can be responsible for short  
filterruns, requiringfrequentcleaning.  
b. Elements may be loaded with oils, debris, etc.  
Clean elements, refer to Cleaning Filter Elements  
onpage 11.  
c. Overcharging with D.E., refer to page 8.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
Troubleshooting, cont’d.  
Problems and Corrective Actions  
Problem  
CorrectiveAction  
PRESSURE DROPS ON GAUGE  
a. If pressure drops on gauge, shut off power to  
pump and turn motor shaft with your fingers.  
If it turns freely then the pump must be  
disassembled and the impeller checked to see  
if it is clogged. If it is not frozen or clogged then  
there is an obstruction in the line between the  
pool and the pump.  
PRESSURE REMAINS HIGH  
AFTER BACKWASH  
a. If pressure remains high after backwash -  
backwash filter again. If still high, treat for  
conditions covered by LIMING-UP above.  
MAINTAIN YOUR PRESSURE GAUGE  
IN GOOD WORKING ORDER  
The pressure gauge is an important part of the  
filter system. It is your primary indicator of how  
the system is operating.  
a. Check the operation of your pressure gauge  
in the following manner:  
(1) The pressure gauge should go to zero (0)  
when the system is turned off and pressure  
is relieved.  
(2) Thepressuregaugeshouldindicatepressure  
when the system is operating.  
(3) Thepressuregaugeshouldbereadableand  
not damaged in any way.  
(4) Replace the pressure gauge if it is not  
meeting the requirements of items  
(1) through (3) of this section.  
DIATOMITE IS CONTINUOUSLY  
ENTERING THE POOL  
a. Inspect the elements for any tears or holes.  
b. Inspect the internal air bleed sock for tears  
andproperinstallation.  
c. Inspect the elements and make sure the elements  
arepositionedverticallyandproperlyseated  
betweentheuppermanifoldandlowermanifold.  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
Section 7  
Replacement Parts  
Replacement Parts List  
1
ITEM P/N  
DESCRIPTION  
1
2
2
2
3
4
5
6
6
6
7
7
7
8
8
8
9
98220100 ASSY. MANUAL AIR RELIEF VALVE  
170024 LID, QUAD 60  
2
3
4
178581 LID, QUAD 80  
178582 LID, QUAD 100  
178616 SPRING COMPRESSION - CNC PLS  
178576 ADAPTER, SHORT  
5
170014 MANIFOLD TOP CART - CNC PLS  
170029 AIR BLEEDER ASSY., QUAD 60  
170028 AIR BLEEDER ASSY., QUAD 80  
178583 AIR BLEEDER ASSY., QUAD 100  
190156 CARTRIDGE, QUAD 100  
6
7
190152 CARTRIDGE, QUAD 80  
190151 CARTRIDGE, QUAD 60  
195981 BACKWASH ASSY. - QUAD DE 60  
195982 BACKWASH ASSY. - QUAD DE 80  
195983 BACKWASH ASSY. - QUAD DE 100  
170059 MANIFOLD ASSY. BOTTOM - QUAD DE  
8
9
10 53008600 CLAMP RPM FLT FINISHED  
11 39010200 O-RING RPM TANK CLAMP  
12 195339 RING BACKUP- FNS PLS CNC PLS  
13 190039 BAFFLE ASSY. - CNC PLS  
14 354571 O-RING 200-830 QUICK CONN.  
15 178567 PIPE OUTLET - RPM FLTR  
16 190089 BOTTOM TANK W/DRAIN PLUG 7.5"  
17 178575 BULKHEAD BOTTOM - FNS PLS  
18 194801 BULKHEAD - FNS 2 3/8-8 BUTT  
19 86006900 O-RING 2-329 BULKHEAD RPM  
20 194997 NUT - FNS/INS SPL  
23  
10  
22  
11  
12  
21  
20  
21 195611 WASHER - FNS/INS LG ID  
22 195612 SPRING- FNS/INS  
13  
14  
15  
16  
19  
18  
17  
23 195610 WASHER - FNS/INS SM ID  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
Section 8  
Technical Data  
Head Loss Comparison Curves  
QUAD D.E.® CARTRIDGE STYLE FILTER  
HEAD LOSS COMPARISON  
11  
10  
9
8
7
BEFORE  
CLEANABILITY  
6
5
AFTER  
CLEANABILITY  
4
3
2
1
0
20 30 40 50 60 70 80 90 100 110 120 130 140  
FILTER FLOW RATE G.P.M.  
Flow Rate Table  
QUAD D.E.® CARTRIDGE STYLE FILTER  
Recommended Flow Rate  
Filter  
Flow Rate GPM Res. Turnover Capacity (Gallons)  
Vertical*  
Clearance  
Product # Model #  
Area Sq.  
Ft.  
Res.** Comm. 6 hours  
8 hours  
57,600  
76,800  
76,800  
12 hours  
86,400  
188592 Quad 60  
188593 Quad 80  
188594 Quad 100  
60  
80  
62"  
68"  
74"  
120  
160  
160  
150  
150  
150  
43,200  
57,600  
57,600  
115,200  
115,200  
100  
NOTE: Actual system flow will depend on plumbing size and other system components.  
Required clearance to remove filter elements.  
*
** Maximum flow rate.  
SAVE THESE INSTRUCTIONS  
Quad D.E.® Filter Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
QuadD.E.®  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P/N 178658 Rev. B 6/4/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  

PC Chips Computer Drive A929 User Manual
Peavey Music Mixer AMR 64 User Manual
Philips Carrying Case SJM3400H User Manual
Philips DVD Recorder DVDR630VR User Manual
Philips MP3 Docking Station DS8500 User Manual
Philips MP3 Docking Station SBD6050 User Manual
Philips Network Router SL300I User Manual
Philips Work Light ED 37 User Manual
Pioneer Musical Instrument CT4 B User Manual
Polk Audio Car Speaker GNX104 4 User Manual