Pelco Security Camera MRU User Manual

®
MR4000/MRU  
Monitor Mounts  
Installation/Operation Manual  
C233M-G (8/95)  
Pelco • 300 W. Pontiac Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-559) 292-1981  
FAX (800) 289-9150 or (1-559) 292-3827 • DataFax (800) 289-9108 or (1-559) 292-0435  
International customers call (1-559) 292-1981 or FAX (1-559) 348-1120  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIST OF ILLUSTRATIONS  
Figure  
Page  
1
2
3
Monitor Assembly ..............................................................................3  
MR4000 Exploded Assembly .............................................................6  
Dimension Drawings ..........................................................................7  
LIST OF TABLES  
Table  
Page  
Mechanical Parts List: MR4000/MRU Universal Mounts ...................6  
A
REVISION HISTORY  
Manual #  
Date  
Comments  
C233M-G  
8/95  
Rev. G. Revised Figure 3 and Section 7.0, Parts List, to  
include item 16.  
5/97  
Revised warnings section and put into new format.  
Pelco Manual C233M-G (8/95)  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(This page intentionally left blank.)  
iv
Pelco Manual C233M-G (8/95)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.0 GENERAL  
1.1 IMPORTANT SAFEGUARDS AND WARNINGS  
Prior to installation and use of this product, the following WARNINGS should be  
observed.  
1. Installation and servicing should only be done by Qualified Service Personnel  
and conform to all Local codes.  
2. Installation shall be done in accordance with all local and national electrical  
and mechanical codes utilizing only approved materials.  
3. Use only installation methods and materials capable of supporting four (4)  
times the maximum specified load.  
4. Use stainless steel hardware to fasten the mount to outdoor surfaces.  
5. To prevent damage from water leakage when installing a mount outdoors on a  
roof or wall, apply sealant around the bolt holes between the mount and mount-  
ing surface.  
The product and/or manual may bear the following mark:  
This symbol indicates that there are important operating and  
maintenance instructions in the literature accompanying this  
unit.  
Please thoroughly familiarize yourself with the information  
in this manual prior to installation and operation.  
Pelco Manual C233M-G (8/95)  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.0 DESCRIPTION  
The MRU/MR4000 Universal Monitor/Receiver Mounts are engineered to safely  
mount a monitor/receiver from either a ceiling or a wall. They were designed for  
use in security systems, educational institutions, churches, hospitals, and other  
applications requiring flexibility in monitor/receiver mounting and positioning.  
The MRU/MR4000 will accept monitors/receivers from 19-31 inches (48.26-78.74 cm)  
wide. The MRU is designed to safely mount monitors/receivers with side mounting  
holes, and the MR4000 has the added feature of a monitor support pan. An 8-inch  
(20.32 cm) section of 1.5-inch (3.81 cm) threaded pipe is furnished with the mount to  
allow for either ceiling or wall mounting. Two optional adapters are available for this  
mount: the MRWA for wall mounting and the MRCA for ceiling mounting.  
2
Pelco Manual C233M-G (8/95)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.0 INSTALLATION  
Installation instructions for the MR4000 and MRU universal monitor/receiver mounts  
are divided into two sections. Follow the steps outlined in order to assure a proper  
set-up.  
3.1 MR4000 ASSEMBLY  
3.1.1 Monitor Assembly (See Figure 1)  
1. Determine the location of the monitor mounting brackets. It will be most con-  
venient to mount the brackets to the bottom of the monitor in place of the  
rubber “feet”.  
2. Remove the monitor rubber “feet” and install the monitor brackets in their place,  
using the original hardware.  
3.1.2 Hanger Assembly (See Figure 2)  
1. Set the monitor assembly on the pan brackets (Item 1). This will help gauge  
the rough positioning of the other brackets.  
2. Fit together the top bracket (Item 3) and the two side arms (Item 4) and place  
over the monitor assembly. Adjust each side arm equally outward to align the  
fastener holes. Using the four (4) 1/4-20 x 5/8 hex bolts, flat washers,  
lockwashers and hex nuts supplied, fasten the arms to the bracket.  
3. Lift the top bracket assembly up until one of the holes in the side arms aligns  
with the 1/2-13 threaded holes in the pan assemblies. Fasten the pan assem-  
blies to the top bracket assembly with the two (2) 1/2-13 x 3/4 hex bolts sup-  
plied.  
4. Remove the monitor assembly from the hanger assembly.  
5. Thread the mounting pipe (Item 6) with the long-threaded section of pipe with  
hole for cotter pin into the top bracket, insert cotter pin, and tighten the 8-32  
screw in the pipe nut to lock the pipe threads.  
Figure 1. Monitor Assembly  
Pelco Manual C233M-G (8/95)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.1.3 Mounting the Hanger Assembly  
NOTE: When determining the  
mounting location, consideration  
must be given to the total weight of  
the monitor and the mount. The  
mounting surface must be adequate  
to support this weight.  
1. Determine the location for, and the type of mount to be used. Remember to  
allow for adequate clearance on all sides of the monitor.  
2. Use the adapter mount as a template to mark the required mounting holes.  
3. Using the necessary fasteners, attach the adapter mount to the chosen sur-  
face.  
4. Thread the mounting pipe into the mount, stopping at the desired position,  
after the threads have become tight (approximately 30 ft lb). (If the MRCA or  
MRWA is being used, tighten the 8-32 screw in the pipe nut to lock the pipe  
threads.)  
3.1.4 Monitor Mounting  
1. Set the monitor assembly into the mounted hanger assembly.  
2. Align the threaded inserts in the monitor brackets with the slots in the pan  
bracket.  
3. Secure the monitor assembly to the hanger assembly with the #10 screws,  
lockwasher, and flat washers supplied. (See Figure 2)  
4. Tilt the monitor to the desired angle and tighten the 1/2-13 hex bolts.  
5. Make all necessary electrical connections.  
4
Pelco Manual C233M-G (8/95)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2 MRU ASSEMBLY INSTRUCTIONS  
3.2.1 Hanger Assembly  
1. Fit together the top bracket and the two side arms and place over the monitor/  
receiver. Adjust each side arm equally outward to align the fastener holes.  
Using the four (4) 1/4-20 x 5/8 hex bolts, flat washers, lock washers and hex  
nuts supplied, fasten the arms to the top bracket.  
2. Remove the monitor from the hanger assembly.  
3. Thread the mounting pipe with the long-threaded section of pipe with hole for  
cotter pin into the top bracket, insert cotter pin, and tighten the 8-32 screw in  
the pipe nut to lock the pipe threads.  
3.2.2 Mounting the Hanger Assembly  
1. Determine the location for, and the type of mount to be used. Remember to  
allow for adequate clearance on all sides of the monitor.  
NOTE: When determining the  
mounting location, consideration  
must be given to the total weight of  
the monitor and the mount. The  
mounting surface must be adequate  
to support this weight.  
2. Use the adapter mount as a template to mark the required mounting holes.  
3. Using the necessary fasteners, attach the adapter mount to the chosen sur-  
face.  
4. Thread the mounting pipe into the mount, stopping at the desired position,  
after the threads have become tight, approximately 30 ft lb. (If the MRCA or  
MRWA is being used, tighten the 8-32 screw in the pipe nut to lock the pipe  
threads.)  
3.2.3 Monitor Mounting  
1. Align the holes in the side arms of the monitor bracket with the threaded holes  
in the side of the monitor/receiver.  
2. Attached the monitor/receiver to the mount with the supplied fasteners  
3. Tilt the monitor to the desired angle and tighten the fasteners.  
4. Make all necessary electrical connections.  
Pelco Manual C233M-G (8/95)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.0 EXPLODED ASSEMBLY  
An exploded assembly diagram for the MR4000 is shown in Figure 2. Items noted with an asterisk in the parts list (Table A) are parts  
used for the MRU mount.  
Figure 2. MR4000 Exploded Assembly  
Table A. Mechanical Parts List: MR4000/MRU Universal Mounts  
Item No.  
Qty  
Description  
Part Number  
1
2
3
2
2
1
Bracket, Pan, Side  
Bracket, Monitor  
Bracket, Top, Horizontal*  
Arm, Top Side*  
MR40004100COMP  
MR40004001COMP  
MRU1001WA  
4
2
MRU1000WA  
5
6
7
8
1
2
8
4
8
4
4
4
Not used  
Pipe Mounting MRU*  
Bolt, 1/2-13 x 3/4 Hex, SS*  
Nut, 1/4-20 Hex, SS*  
Bolt, 1/4-20 x 5/8 Hex C/S SS*  
Not used  
Washer, Split Lock 1/4 SS Medium*  
Screw, 10-32 x 1/2 Pan Phil, SS  
Washer, Split Lock #10, SS Medium  
Washer, Flat #10, SS  
Washer, Flat 3/16*  
MRU4207COMP  
ZH1/213X.750CH  
ZH1/4-20NUTCH  
ZH1/420X.625CH  
9
10  
11  
12  
13  
14  
15  
16  
ZH1/4LWSSL  
ZH10-32X.500SPP  
ZH10LWSSL  
ZH204X436X60C  
ZH260X562X65C  
ZH515X875X62  
8
2
Washer, Flat 1/2  
*Denotes parts used for MRU mount.  
6
Pelco Manual C233M-G (8/95)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.0 SPECIFICATIONS  
Construction:  
Finish:  
Steel  
Polyester powder coat  
150 lbs (68 kg)  
See Figure 3  
20 lbs (9 kg)  
Maximum Load:  
Dimensions:  
Weight:  
Shipping Weight: 22 lbs (10 kg)  
MRWA  
MR4000  
MRCA  
Figure 3. Dimension Drawings  
Pelco Manual C233M-G (8/95)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.0 WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in  
material or workmanship for a period of one (1) year after the date of shipment.  
Exceptions to this warranty are as noted below:  
Two (2) years on all standard motorized and fixed focal length lenses.  
Two (2) years on Legacy®, Intercept®, CM8500/CM9500/CM9750 Matrix,  
Spectra, DF5 Series and DF8 Fixed Dome products.  
Two (2) years on WW5700 series window wiper (excluding wiper blades).  
Two (2) years on cameras.  
Six (6) months on all pan and tilts, scanners or preset lenses used in continu-  
ous motion applications (e.g., preset scan, tour and auto scan modes).  
Pelco will warranty all replacement parts and repairs for 90 days from the date of  
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to  
Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration,  
normal wear, or accident are not covered under this warranty.  
Pelco assumes no risk and shall be subject to no liability for damages or loss result-  
ing from the specific use or application made of the Products. Pelco’s liability for  
any claim, whether based on breach of contract, negligence, infringement of any  
rights of any party or product liability, relating to the Products shall not exceed the  
price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable  
for any special, incidental or consequential damages (including loss of use, loss of  
profit and claims of third parties) however caused, whether by the negligence of  
Pelco or otherwise.  
The above warranty provides the Dealer with specific legal rights. The Dealer may  
also have additional rights, which are subject to variation from state to state.  
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the  
following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
If there is a dispute regarding the warranty of a product which does not fall under  
the warranty conditions stated above, please include a written explanation with the  
product when returned.  
Ship freight prepaid to:  
Pelco  
300 West Pontiac Way  
Clovis, CA 93612-5699  
Method of return shipment shall be the same or equal to the method by which the  
item was received by Pelco.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the  
factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA  
number if returned for credit, and RA number if returned for repair). Goods returned  
for repair or credit should be clearly identified with the assigned CA/RA number and  
freight should be prepaid. All merchandise returned for credit may be subject to a  
20% restocking and refurbishing charge.  
®Pelco and the Pelco logo are  
registered trademarks of Pelco.  
©Copyright 1997, Pelco. All rights  
reserved.  
Ship freight prepaid to:  
Pelco  
300 West Pontiac Way  
Clovis, CA 93612-5699  
8
Pelco Manual C233M-G (8/95)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Pentax Digital Camera 19196 User Manual
Philips Computer Monitor 107E71 User Manual
Philips CRT Television 14PT2001 User Manual
Philips DVD Player MDV460 User Manual
Philips Universal Remote RC2573GR User Manual
Polaroid Digital Camera I533 User Manual
Porsche Automobile 911 Carrera User Manual
Poulan Trimmer RTE115 User Manual
Poulan Trimmer S17DE User Manual
ProForm Treadmill 831296050 User Manual