Panasonic Air Conditioner CS PC30JKF User Manual

F566726  
Operating Instructions  
Air Conditioner  
Indoor Unit  
Outdoor Unit  
CS-PC30JKF CU-PC30JKF  
CS-PC36JKF CU-PC36JKF  
٧
 ~
٢  
ENGLISH  
8 ~ 13  
Before operating the unit, read these  
operating instructions thoroughly and  
keep them for future reference.  
ﺳﺮﻳ
 
ﻴﻞ
ﺩﻟ
 
QUICK GUIDE  
© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2008.  
Unauthorized copying and distribution is a violation  
of law.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Thank you for purchasing  
Panasonic Air Conditioner  
RREEGGUULLAATTOORRYY IINNFFOORRMMAATTIIOONN  
This appliance is not intended for use by persons (including children) with reduced  
physical, sensory or mental capabilities, or lack of experience and knowledge,  
unless they have been given supervision or instruction concerning use of the  
appliance by a person responsible for their safety. Children should be supervised to  
ensure that they do not play with the appliance.  
TABLE OF CONNTENTS  
SAFETY PRECAUTIONS  
8
REGULATORY INFORMATION  
9
OPERATION CONDITION  
Use this air conditioner under the following temperature range  
(CU-PC30JKF)  
PRODUCT OVERVIEW &  
OPERATIONS  
10~11  
Indoor  
*DBT  
Outdoor  
CARE & CLEANING  
TROUBLESHOOTING  
QUICK GUIDE  
Temperature (°C)  
*WBT  
23  
*DBT  
*WBT  
31  
12  
Maximum  
Minimum  
32  
16  
55  
16  
COOLING  
13  
11  
11  
BACK COVER  
(CU-PC36JKF)  
Indoor  
Outdoor  
NOTE :  
Temperature (°C)  
*DBT  
32  
*WBT  
23  
*DBT  
52  
*WBT  
31  
The illustrations in this manual are  
for explanation purposes only and  
may differ from the actual unit. It is  
subjected to change without notice  
for future improvement.  
Maximum  
Minimum  
COOLING  
16  
11  
16  
11  
* DBT: Dry bulb temperature  
* WBT: Wet bulb temperature  
Information for Users on Collection and Disposal of Old Equipment and used Batteries  
[Information on Disposal in other Countries outside the European Union]  
These symbols are only valid in the European Union. If you wish to discard these items, please contact your  
local authorities or dealer and ask for the correct method of disposal.  
Note for the battery symbol (bottom two symbol examples):  
This symbol might be used in combination with a chemical symbol. In this case it complies with the  
requirement set by the Directive for the chemical involved.  
Pb  
• Do not switch ON the unit when waxing the oor. After waxing, aerate the room properly before operating the unit.  
• Do not install the unit in oily and smoky areas.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT OVERVIEW & OPERATIONS  
Air Filters  
Auto OFF/ON button  
Used when remote control is misplaced  
or malfunction.  
Front panel  
Action  
Mode  
Press once.  
Auto  
Press and hold until 1 beep  
is heard, then release.  
Cooling  
Press the button to turn off.  
INDICATOR  
POWER (Green)  
TIMER  
(Orange)  
Horizontal airow  
direction louver  
• Manually  
Receiver  
Vertical airow  
direction louver  
• Do not adjust  
by hand.  
adjustable.  
Maximum distances: 8m  
Remote control  
display  
SPEED  
SWING  
OFF/ON  
FA  
N
S
P
EED  
TEM  
P
ON  
1
SET  
3
2
OFF  
CANCEL  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO SET THE TIMER  
TO TURN ON OR OFF THE UNIT  
• To turn ON or OFF the unit at a preset time.  
• Please be aware of the OFF indication on the remote  
control display to prevent the unit from starting/  
stopping improperly.  
TO SET TEMPERATURE  
Select ON or  
OFF timer.  
Set the time.  
Conrm.  
• Selection range : 16°C ~ 30°C.  
• To cancel ON or OFF timer, press  
press  
or  
then  
• Operating the unit within the recommended  
temperature could induce energy saving.  
COOL mode : 26˚C ~ 28˚C.  
.
• When ON Timer is set, the unit may start earlier (up  
to 15 minutes) before the actual set time in order to  
achieve the desired temperature on time.  
DRY mode : 1˚C ~ 2˚C lower than room temperature.  
TO SELECT OPERATION MODE  
• Timer operation is based on the clock set in the remote  
control and repeats daily once set. For clock setting,  
please refer to Remote Control Preparation at back  
cover.  
AUTO mode - For your convenience  
• Unit selects the operation mode according to the  
room temperature.  
COOL mode - To enjoy cool air  
• If timer is cancelled manually or due to power failure,  
you can restore the previous setting (once power is  
DRY mode - To dehumidify the environment  
• Unit operates at low fan speed to give a gentle  
cooling operation.  
resumed) by pressing  
.
TO SELECT FAN SPEED  
(3 OPTIONS)  
OPTIONNAL SETTINGS  
Press and hold for approximately 10  
seconds to show temperature setting in  
°C or °F.  
• For AUTO, the indoor fan speed is automatically  
adjusted according to the operation mode.  
TO ADJUST VERTICAL AIRFLOW  
DIRECTION (4 OPTIONS)  
Press and hold for approximately 5 seconds  
to show 12-hour (am/pm) or 24-hour time  
indication.  
CLOCK  
Press to restore the remote control’s default  
setting.  
• Keeps the room ventilated.  
• If AUTO is set, the louvers swing up/down  
automatically.  
RESET  
Use curtains to screen off sunlight and outdoor heat to  
reduce power consumption during cool mode.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARE & CLEANING  
Switch off the power supply before cleaning.  
Do not touch the aluminium n, sharp parts may cause injury.  
CAUTION  
HINT  
WASHING INSTRUCTIONS  
• Do not use benzene, thinner or scouring powder.  
• Use only soap ( pH7) or neutral household detergent.  
• Do not use water hotter than 40°C.  
• To ensure optimal performance of the unit, cleaning  
maintenance have to be carried out at regular intervals.  
Please consult authorized dealer.  
FRONT PANEL  
ALUMINIUM FIN  
Remove Front Panel  
• Raise and pull to remove the  
front panel.  
• Wash gently and dry.  
Close Front Panel  
• Press down both ends of the  
front panel to close it securely.  
Remove  
INDOOR UNIT  
Wipe the unit gently with a soft,  
dry cloth.  
AIR FILTERS  
• Air lters cleaning is needed every two weeks.  
• Wash/rinse the lter gently with water to avoid  
damage to the lter surface.  
• Dry the lters thoroughly under the shade, away from  
re or direct sunlight.  
• Replace any damaged lter.  
FOR SEASONAL INSPECTION AFTER EEXXTTEENNDDEEDD  
NON SERVICEABLE CRITERIAS  
NON-USE  
• Checking of remote control batteries.  
TURN OFF POWER SUPPLY then please consult  
authorized dealer under the following conditions:  
• No obstruction at air inlet and air outlet vents.  
• Abnormal noise during operation.  
• After 15 minutes of operation, it is normal to have the  
following temperature difference between air inlet and air  
outlet vents:  
• Water/foreign particles have entered the remote control.  
• Water leaks from Indoor unit.  
Cooling: 8°C  
• Circuit breaker switches off frequently.  
• Power cord becomes unnaturally warm.  
• Switches or buttons are not functioning properly.  
FOR EXTENDED NON-USE  
• Turn off the power supply.  
• Remove the remote control batteries.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TTRROOUUBBLLEESSHHOOOOTTIINNGG  
The folllowinngg symptooms do nnot iinnddiiccaatte mmaallffuunnccttiioonn..  
Symptom  
Cause  
Mist emerges from indoor unit.  
Water owing sound during operation.  
The room has a peculiar odour.  
• Condensation effect due to cooling process.  
• Refrigerant ow inside the unit.  
• This may due to damp smell emitted by the wall, carpet, furniture or  
clothing.  
Indoor fan stops occasionally during automatic • This helps to remove the surrounding odours.  
fan speed setting.  
Operation is delayed a few minutes after  
restart.  
• The delay is a protection to the unit’s compressor.  
Outdoor unit emits water/steam.  
Timer indicator is always on.  
Cracking sound during operation.  
• Condensation or evaporation occurs on pipes.  
• The timer setting repeats daily once set.  
• Changes of temperature cause the expansion/contraction of the unit.  
Checkk the folllowinng befoorre calliing forr sserviicing.  
Symptom  
Check  
Cooling operation is not working efciently.  
• Set the temperature correctly.  
• Close all doors and windows.  
• Clean or replace the lters.  
• Clear any obstruction at the air inlet and air outlet vents.  
Noisy during operation.  
• Check if the unit has been installed at an incline.  
• Close the front panel properly.  
Remote control does not work.  
• Insert the batteries correctly.  
(Display is dim or transmission signal is weak.) • Replace weak batteries.  
The unit does not work.  
• Check if the circuit breaker is tripped.  
• Check if timers have been set.  
The unit does not receive the signal from the  
remote control.  
• Make sure the receiver not obstructed.  
• Certain uorescent lights may interfere with signal transmitter. Please  
consult authorized dealer.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ﺳﺮﻳ
 
ﺩﻟﻴﻞ
 
//QQUUIICCKK GGUUIIDDEE  
ﺑﻌ
 
 
ﺤﻜ
ﺍﻟ
 
ﻭﺣﺪ
 
ﲢﻀ
 • Remote Control Preparation  
1
2
ﺍﺳﺤ
 Pull out  
1
2
(
ﻭﺍﺣﺪﺓ
 
ﺳﻨﺔ
 
ﳌﺪﺓ
 
ﺍﺳﺘﺨﺪﺍﻣﻬﺎ
 
ﳝﻜﻦ
) R03 
ﺃﻭ
 AAA 
ﺑﻄﺎﺭﻳﺎﺕ
 
ﺍﺩﺧﻞ
 •  
Insert AAA or R03 batteries (can be used ~ 1 year)  
3
3
4
5
6
ﺍﻟﻐﻄﺎ
 
ﺍﻏﻠﻖ
 Close the cover  
CLOCK 
ﺍﺿﻐﻂ
 Press CLOCK  
4
TIMER  
ON  
5
6
ﺍﻟﻮﻗ
 
ﺍﺿﺒﻂ
 Set time  
SET  
1
2
3
ﺗﺄﻛ
 Conrm  
OFF  
CANCEL  
RESET  
CLOCK  
1
.
ﺍﳌﺮﻏﻮﺏ
 
ﺍﻟﻮﺿﻊ
 
ﺍﺧﺘﻴﺎﺭ
 
Select the desired mode.  
AUTO  
FAN  
DRY COOL  
AUTO  
COOL  
DRY  
SPEED  
AIR  
SWING  
OFF  
OFF  
ON  
2
TIMER  
TIMER  
OFF/ON  
.
ﺍﻟﺘﺸﻐﻴﻞ
 
ﺍﻳﻘﺎﻑ
/
ﺑﺪﺀ
 
Start/stop the operation.  
MODE  
FAN SPEED  
AIR SWING  
TEMP  
TIMER  
ON  
SET  
3
1
2
3
OFF  
CANCEL  
RESET  
.
ﺍﳌﺮﻏﻮﺑﺔ
 
ﺍﳊﺮﺍﺭﺓ
 
ﺩﺭﺟﺔ
 
ﺍﺧﺘﻴﺎﺭ
 
Select the desired temperature.  
CLOCK  
Panasonic Corporation  
Printed in Malaysia  
F566726  
OYSC0901-01  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Milwaukee Battery Charger 48 59 0231 User Manual
Murphy Switch WAI Series User Manual
Navigon GPS Receiver SmartMirror User Manual
Netopia Network Router 3366C ENT User Manual
Nilfisk ALTO Vacuum Cleaner 751 61 User Manual
Nilfisk ALTO Ventilation Hood MX 521 H User Manual
Panasonic Camera Accessories AJ PCD10P User Manual
Panasonic Smoke Alarm 3378 User Manual
Parkside Glue Gun PHKP 500SE User Manual
Patterson Kelley Boiler DVSCM 02 User Manual