Oregon Scientific Radar Detector BAR206 User Manual

Weather Forecast Station with  
Atomic Time  
Model: BAR206 / BAR206A  
USER MANUAL  
CONTENTS  
Overview .....................................................................2  
Front View ..............................................................2  
Back View ..............................................................2  
Remote Sensor .......................................................3  
Getting Started ...........................................................3  
Insert Batteries........................................................3  
Remote Sensor...........................................................3  
Sensor Data Transmission......................................4  
Clock ...........................................................................4  
Clock Reception......................................................4  
Manually Set Clock .................................................5  
Weather Forecast.......................................................5  
Temperature And Humidity ......................................6  
Ice Warning.............................................................6  
Backlight ....................................................................6  
Reset...........................................................................6  
Precautions................................................................6  
Specifications ............................................................7  
About Oregon Scientific ...........................................7  
EU-Declaration of Conformity ..................................7  
FCC Statement...........................................................7  
Declaration of Conformity........................................8  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. °C / °F: Select temperature unit  
2. RESET: Reset unit to default settings  
3. EU / UK: Select the nearest radio signal (BAR206  
only)  
2. Insert the batteries, matching the polarities (see FIG 2).  
3. Press RESET after each battery change.  
LOCATION  
MEANING  
Clock / alarm and indoor  
temperature area  
Main unit batteries low  
REMOTE SENSOR (FIG 3)  
Outdoor temperature area  
Sensor batteries low  
2
REMOTE SENSOR  
The main unit can collect data from up to 3 sensors.  
1
4
To set up the sensor:  
3
5
1. Open the battery compartment (see FIG 3).  
2. Select a channel then press RESET.  
3. Close the battery door.  
4. Place the sensor within 30 m (98 ft) of the main unit  
using the table stand or wall mount.  
TIP Ideal placements for the sensor would be in any  
location on the exterior of the home at a height of not  
more than 1.5 m (5 ft) and which can shield it from direct  
sunlight or wet conditions for an accurate reading.  
1. LED status indicator  
2. Wall mount hole  
3. Battery compartment  
4. RESET hole  
5. CHANNEL switch  
GETTING STARTED  
INSERT BATTERIES  
1. Remove the battery compartment.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
A channel has been found.  
The sensor cannot be found.  
TIP The transmission range may vary depending  
on many factors. You may need to experiment with  
various locations to get the best results.  
1.5 m (5 ft)  
CLOCK  
CLOCK RECEPTION  
This product is designed to synchronize its clock  
automatically with a clock signal.  
Use alkaline batteries for longer usage and  
consumer grade lithium batteries in temperatures below  
freezing.  
BAR206:  
Slide EU / UK to select the signal received.  
EU: DCF-77 signal: within 1500 km (932 miles) of  
Frankfurt, Germany.  
SENSOR DATA TRANSMISSION  
To search for a sensor:  
UK: MSF-60 signal: within 1500 km (932 miles) of  
Anthorn, England.  
Press and hold  
+ MODE.  
BAR206A:  
WWVB-60 signal: within 3200km (2000 miles) of Fort  
Collins Colorado.  
The sensor reception icon in the remote sensor area  
shows the status:  
ICON  
DESCRIPTION  
Main unit is searching for  
sensor(s).  
To enable / disable signal reception:  
Press and hold  
reception.  
to enable or  
to disable signal  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
To select display mode:  
Press MODE to choose between clock with seconds /  
weekday / calendar.  
Reception takes 2-10 minutes. If the signal is  
weak, it can take up to 24 hours to get a valid signal.  
If signal reception is unsuccessful, place your unit next  
to a window, press and hold  
search.  
to force another signal  
WEATHER FORECAST  
Clock signal reception indicator:  
This product forecasts the next 12 to 24 hours of  
weather within a 30-50 km (19-31 mile) radius with a  
75% accuracy.  
STRONG SIGNAL  
WEAK SIGNAL NO SIGNAL  
Sunny  
Partially Cloudy  
Cloudy  
MANUALLY SET CLOCK  
To set the clock manually, disable the signal reception  
first.  
1. Press and hold MODE.  
2. Press  
or  
to change the settings.  
3. Press MODE to confirm.  
4. The settings order is: time zone, 12/24 hr format,  
hour, minute, year, calendar mode (day – month /  
month – day), month, day and language.  
Rainy  
BAR206: Time zone offset sets the clock +/- 23 hours  
from the received clock signal time.  
Snowy  
BAR206A: Select the time zone: (P) Pacific, (E)  
Eastern, (C) Central or (M) Mountain.  
The language options are English (E), German  
(D), French (F), Italian (I), and Spanish (S).  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
TEMPERATURE AND HUMIDITY  
PRECAUTIONS  
Do not subject the unit to excessive force, shock,  
dust, temperature or humidity.  
Do not cover the ventilation holes with any items  
such as newspapers, curtains etc.  
Do not immerse the unit in water. If you spill liquid  
over it, dry it immediately with a soft, lint-free cloth.  
Do not clean the unit with abrasive or corrosive  
materials.  
Do not tamper with the unit’s internal components.  
This invalidates the warranty.  
Only use fresh batteries. Do not mix new and old  
batteries.  
Images shown in this manual may differ from the  
actual display.  
When disposing of this product, ensure it is collected  
separately for special treatment.  
Placement of this product on certain types of  
wood may result in damage to its finish for which  
Oregon Scientific will not be responsible. Consult  
the furniture manufacturer's care instructions for  
information.  
The contents of this manual may not be reproduced  
without the permission of the manufacturer.  
Do not dispose old batteries as unsorted municipal  
waste. Collection of such waste separately for  
special treatment is necessary.  
To toggle temperature unit:  
Press °C / °F.  
To auto-scan between sensors:  
Press and hold  
for 3 seconds.  
To end press  
+ MEM to display each sensor’s data  
.
To toggle between current, minimum and maximum  
records for the selected sensor:  
Press MEM repeatedly.  
To clear the records:  
Press and hold MEM.  
ICE WARNING  
If the channel 1 sensor falls between 3°C to -2 °C (37°F  
to 28°F), LED indicator will flash, and will stop flashing  
once the temperature is out of this range.  
BACKLIGHT  
Press LIGHT to activate backlight for 5 seconds.  
Please note that some units are equipped with a  
battery safety strip. Remove the strip from the  
battery compartment before first use.  
RESET  
The technical specifications for this product and  
the contents of the user manual are subject to change  
without notice.  
Press RESET to return to the default settings.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
com/service/support  
OR  
SPECIFICATIONS  
TYPE  
DESCRIPTION  
Call 1-800-853-8883.  
For international inquiries, please visit: www2.  
oregonscientific.com/about/international  
MAIN UNIT  
L x W x H  
94 x 49 x 164 mm  
(3.70 x 1.93 x 6.46 in)  
Weight  
241 g (8.5 oz) without battery  
EU-DECLARTION OF CONFORMITY  
Temperature range -5°C to 50°C (23°F to 122°F)  
Hereby, Oregon Scientific, declares that this Weather  
Forecast Station with Atomic Time (Model: BAR206 /  
BAR206A) is in compliance with the essential requirements  
and other relevant provisions of Directive 1999/5/EC. A  
copy of the signed and dated Declaration of Conformity  
is available on request via our Oregon Scientific  
Customer Service.  
Resolution  
0.1°C (0.2°F)  
433 MHz  
Signal frequency  
Humidity range  
25% - 95%  
Humidity resolution 1%  
Power  
3 x UM-3 (AA) 1.5 V batteries  
REMOTE UNIT (THN132N)  
L x W x H  
96 x 50 x 22 mm  
(3.78 x 1.97 x 0.87 in)  
Weight  
62 g (2.22 ounces)  
Transmission range 30 m (98 ft) unobstructed  
Temperature range -20°C to 60°C (-4°F to 140°F)  
COUNTRIES RTTE APPROVAL COMPLIED  
All EC countries,Switzerland CH  
Power  
1 x UM-3 (AA) 1.5 V batteries  
and Norway  
N
ABOUT OREGON SCIENTIFIC  
more about Oregon Scientific products. If you’re in  
the US and would like to contact our Customer Care  
department directly, please visit: www2.oregonscientific.  
FCC STATEMENT  
This device complies with Part 15 of the FCC Rules.  
Operation is subject to the following two conditions: (1)  
This device may not cause harmful interference, and  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
(2) This device must accept any interference received,  
including interference that may cause undesired  
operation.  
DECLARATION OF CONFORMITY  
The following information is not to be used as contact  
for support or sales. Please call our customer service  
com, or on the warranty card for this product) for all  
inquiries instead.  
WARNING Changes or modifications not expressly  
approved by the party responsible for compliance could  
void the user’s authority to operate the equipment.  
We  
Name:  
Address:  
NOTE This equipment has been tested and found  
to comply with the limits for a Class B digital device,  
pursuant to Part 15 of the FCC Rules. These limits  
are designed to provide reasonable protection against  
harmful interference in a residential installation.  
Oregon Scientific, Inc.  
19861 SW 95th Ave.,Tualatin,  
Oregon 97062 USA  
Telephone No.:  
1-800-853-8883  
This equipment generates, uses and can radiate radio  
frequency energy and, if not installed and used in  
accordance with the instructions, may cause harmful  
interference to radio communications. However, there  
is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause  
harmful interference to radio or television reception,  
which can be determined by turning the equipment  
off and on, the user is encouraged to try to correct the  
interference by one or more of the following measures:  
declare that the product  
Product No.:  
Product Name:  
BAR206 / BAR206A  
Weather Forecast Station with  
Atomic Time  
IDT Technology Limited  
Block C, 9/F, Kaiser Estate,  
Phase 1,41 Man Yue St.,  
Hung Hom, Kowloon,  
Hong Kong  
Manufacturer:  
Address:  
is in conformity with Part 15 of the FCC Rules. Operation  
is subject to the following two conditions: 1) This device  
may not cause harmful interference. 2) This device must  
accept any interference received, including interference  
that may cause undesired operation.  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment  
and receiver.  
Connect the equipment into an outlet on  
a
circuit different from that to which the receiver is  
connected.  
Consult the dealer or an experienced radio / TV  
technician for help.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
© 2007 Oregon Scientific. All rights reserved.  
P/N: 086L00 sample  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Weather Forecast Station with Atomic Time  
Model: BAR206 / BAR206A  
USER MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Minolta IP Phone IP8815 User Manual
Muratec All in One Printer MFX 1300 1700 User Manual
NEC Projector MultiSync LT 80 User Manual
NETGEAR Network Router WNDR4300 User Manual
NeumannBerlin Power Supply BS 48 i User Manual
Nortech Systems Portable DVD Player E DVKIT003 User Manual
Nortel Networks Digital Camera S560 User Manual
Omnimount TV Mount 4N1 L User Manual
Panasonic Car Stereo System C9801W User Manual
Patton electronic Network Card 1089 I User Manual