Omega Vehicle Security Thermometer HH508 User Manual

OMEGA  
HH508/HH509/HH509R  
Digital Thermometer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
This instrument is a 3½ digit, compact-sized portable digital thermometer  
designed to use external K/J/T/E/S type thermocouples as temperature  
sensor.TemperatureindicationfollowsReferenceTemperature/VoltageTables  
(N.I.S.T. Monograph 175 Revised to ITS-90) for K/J/T/E/S type thermo-  
couples.  
SAFETY INFORMATION  
Itisrecommendedthatyoureadthesafetyandoperationinstructionsbefore  
using the thermometer.  
WARNING  
To avoid electrical shock, do not use this instrument when working  
voltages at the measurement surface over 24V AC or DC.  
WARNING  
To avoid damage or burns, do not make temperature  
measurement in microwave ovens.  
CAUTION  
Repeated sharp flexing can break the thermocouple leads. To prolong  
lead life, avoid sharp bends in the leads, especially near the connector.  
The  
symbol on the instrument indicates that the operator must refer to an  
explanation in this manual.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
ENVIRONMENTAL  
Ambient Operating Ranges: 0°C to 50°C (32°F to 122°F) <80% R.H.  
Storage Temperature: -20°C to 60°C (-4°F to 140°F) <70% R.H.  
GENERAL  
Display:3½digitliquidcrystaldisplay(LCD)withamaximumreadingof1999.  
Polarity: Automatic, positive implied, negative polarity indication.  
Overrange: -OL is displayed.  
Zero: Automatic.  
Reading Rate: one time per second.  
Lowbatteryindication:the"  
"isdisplayedwhenthebatteryvoltagedrops  
below the operating level.  
Measurement rate: 1 times/second.  
Accuracy: Stated accuracy at 23°C±5°C, <75% relative humidity.  
Dimensions: 195mm(H) x 92mm(W) x 53mm(D).  
Weight: 365g.  
Input Connector: Accepts standard miniature thermocouple connectors (flat  
blades spaced 7.9mm, center to center).  
Battery Life: 100 hours typical battery.  
Auto power off: The meter key switch inactive for more than 30 minutes, press  
power key to resume operation.  
Temperature Coefficient: 0.1 times the applicable accuracy specification per °C  
from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to 122°F).  
Input Protection: 24V dc or 24V ac rms maximum input voltage on any  
combination of input pins.  
Maximum Differential Common Mode Voltage (Maximum Voltage between  
T1 and T2 during measurement): 1volt.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL  
Temperature Scale: Celsius or Fahrenheit user-selectable.  
Measurement Range:  
Thermocouple  
K-TYPE(0.1°C)  
J-TYPE(0.1°C)  
T-TYPE(0.1°C)  
E-TYPE(0.1°C)  
S-TYPE(1°C)  
Range  
-200°C to 1372°C, -328°F to 1999°F  
-210°C to 1200°C, -346°F to 1999°F  
-200°C to 400°C, -328°F to 752°F  
-220°C to 1000°C, -364°F to 1832°F  
0°C to 1767°C, 32°F to 1999°F  
Auto range: 0.1°C/1°C, 0.1°F/1°F.  
Accuracy: Accuracy is specified for operating temperatures over the range of  
18°C to 28°C (64°F to 82°F), for 1 year, not including thermocouple error.  
±(0.1% rdg + 1°C) range -60°C to 1372°C  
±(0.1% rdg + 2°C) range -60°C to -220°C  
±(0.1% rdg + 2°F) range -76°F to 1999°F  
±(0.1% rdg + 4°F) range -76°F to -364°F  
S-TYPE  
±(0.0% rdg + 2°C) on 0°C to 50°C  
±(0.1% rdg + 1°C) on 50°C to 1767°C  
±(0.0% rdg + 4°F) on 32°F to 122°F  
±(0.1% rdg + 2°F) on 122°F to 1999°F  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
Power Switch  
The key turns the thermometer on or off. In the MIN MAX record mode  
can not power off, must leave MIN MAX record mode then power off.  
1
2 5  
°C °F Selecting the Temperature Scale  
Readings is displayed in either degrees Celsius(°C) or degrees  
Fahrenheit(°F). When the thermometer is turned on, it is set to the  
temperature scale that was in use when the thermometer was last turned  
off. To change the temperature scale, press the °C or °F key.  
3
4
" " Button  
Press " " button to toggle on and off of backlight. The backlight will switch-  
off automatically after 30 seconds.  
HOLD Mode  
Pressing the HOLD key to enter the Data Hold mode, the "HOLD" annun-  
ciator is displayed. When HOLD mode is selected, the thermometer held  
the present readings and stops all further measurements.  
Pressing the HOLD key again to cancel HOLD mode causing thermometer  
to resume taking measurements.  
In the MIN/MAX recording mode, press HOLD key to stop the recording.  
Press HOLD key again to resume recording. (Previously recorded reading  
are not erased).  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 MIN MAX record Mode  
Press MIN MAX key to enter the MIN MAX Recording mode, (displays the  
Maximum reading, Minimum reading, "MAX-MIN" reading and Average  
reading stored in record mode). In the this mode the automatic power-off  
feature is disabled and key and all function key are disabled. The beeper  
emits a tone when a new minimum or maximum value is recorded.  
Push MIN MAX key to cycle through the MAX, MIN, MAX-MIN and AVG  
readings.  
If an overload is recorded, the averaging function is stopped and average  
value display"-OL".  
In the this mode, press HOLD key to stop the recording of readings, all  
values are frozen, press again to restart recording.  
To prevent accidental loss of MIN, MAX, "MAX-MIN" and AVG data, in this  
mode can only be cancelled by pressing and hold down the MIN MAX key  
for 2 seconds to exit and erased recorded readings.  
WARNING  
MIN, MAX and AVG readings can be recorded for a period of up to 50 hours  
maximum. If this 50 hours period is exceeded the unit readings will not be  
accurate.  
7 8 9  
T1 T2/T1-T2 (for HH501BR/HH501BS)  
The input selection indicates which input is selected for display; T1  
thermocouple, T2 thermocouple or the difference between the two thermo-  
couples (T1-T2), when the thermometer is turned on, when the thermom-  
eter is turned on, it is set to the input selected that was in use when the  
thermometer was last turned off.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
7 8 9 TIMER STOP-WATCH Mode (for HH501AR / HH501AS)  
Press TIMER STOP-W key to enter stop-watch mode stop-watch is  
displayed. Press START/STOP key to toggle stop-watch starts and stops  
(Time goes up to 19 minutes & 59.9 seconds). Press CLEAR key to display  
0.1 second, then press again to zero the stop-watch.  
Press TIMER STOP-W key again to exit the stop-watch mode.  
10  
REL Relative mode  
Pressing REL key to enter the Relative mode, zero the display, and store  
the displayed Reading as a reference value and annunciator REL is  
displayed. Press REL key again to exit the relative mode.  
The relative value can also be entered by the user. (See "SET mode" later  
in this manual.)  
When the desired Relative value has been entered, press REL key to enter  
the Relative mode, press SET key use set Relative value as a reference  
value. Press REL key again to exit the relative mode.  
In the Relative mode, the value (can not >±2000.0 counts) shown on the  
LCD is always the difference between the stored reference and the present  
reading.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
11 SET mode (Relative value set and Hi/Lo Limits value set)  
1. Press SET key to enter Relative valuse SET mode (Press ENTER key  
can escape relative valuse set mode), REL set mode. _ = = =.= is  
displayed (the ".=" is displayed when you set up the fourth umber).  
Relative value is entered via overlay numbers, when you want to get  
negative values push (- 0) key for end of numbers, then press overlay  
ENTER key, stored the relative value, enter Hi/Lo Limits value set mode.  
2. Hi Limit value set mode, (Press ENTER key can escape Hi Limit value set  
mode),_===.=isdisplayed(the".="isdisplayedwhenyousetupthefourth  
number), Hi Limit value is entered via overlay numbers, when you want to  
get negative values push (- 0) key for end of numbers, then press overlay  
ENTER key, stored the Hi Limit value, enter Lo Limit value set mode (Press  
ENTERkeycanescapeLoLimitvaluesetmode), _===.=isdisplayed(the  
".=" is displayed when you set up the fourth number), Lo Limit value is  
entered via overlay numbers, when you want to get negative values push  
(- 0) key for end of numbers, then press overlay ENTER key, stored the Lo  
Limit value and exit set mode.  
3. In the SET mode, the value can not >±2000.0 counts.all value will be  
memorized until yor reset it.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 Hi/Lo LIMITS mode  
Press Hi/Lo LIMITS key to enter the Hi/Lo Limits comparative mode,  
"LIMIT" is displayed. In the this mode the automatic power-off feature is  
disabled and other funtion key are disabled, when input temperature value  
exceed Hi. The beeper emits a continuity pulse tone and "Hi" is displayed,  
and when input temperature value exceed Lo value. The beeper emits a  
discontinuouspulsetoneand"Lo"isdisplayed.PressHi/LoLIMITkeyagain  
to exit the Hi/Lo LIMIT mode.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATOR MAINTENANCE  
WARNING  
To avoid possible electrical shock, disconnect the thermocouple  
connectors from the thermometer before removing the cover.  
Battery Replacement  
Power is supplied by a 9 volt "transistor" battery. (NEDA 1604, IEC 6F22). The  
"
"appearsontheLCDdisplaywhenreplacementisneeded. Toreplacethe  
battery, remove the two screws from the back of the meter and lift off the  
battery cover. Remove the battery from battery contacts.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Operation Using Quick BASIC  
The following example shows how to send command instruction and receive  
data responses over the RS-232 interface using Quick BASIC.  
The program example is set up on "COM1".  
CLS  
E$ = "A"  
ST1:  
CLOSE #1  
OPEN "COM1:1200,E,7,1,DS,RS" FOR OUTPUT AS #1  
PRINT #1, E$;  
CLOSE #1  
OPEN "COM1:1200,E,7,1,DS,RS" FOR RANDOM AS #1  
ST2:  
INPUT #1, A$  
B$ = MID$(A$, 2, 6)  
DEC = 0  
F$ = "0123456789ABCDEF"  
N = 6  
FOR I = 0 TO 5  
C$ = MID$(B$, N, 1)  
N = N - 1  
D = INSTR(F$, C$) - 1  
DEC = DEC + (16 ^ I) * D  
NEXT  
DEC = DEC / 1000  
C$ = MID$(A$, 1, 1)  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IF C$ = "-" THEN  
DEC = DEC * -1  
END IF  
B$ = MID$(A$, 10, 6)  
DEC1 = 0  
N = 6  
FOR I = 0 TO 5  
C$ = MID$(B$, N, 1)  
N = N - 1  
D = INSTR(F$, C$) - 1  
DEC1 = DEC1 + (16 ^ I) * D  
NEXT  
DEC1 = DEC1 / 1000  
C$ = MID$(A$, 9, 1)  
IF C$ = "  
DEC1 = DEC1 * -1  
END IF  
-" THEN  
CLS  
LOCATE 12, 33  
PRINT " T1  
LOCATE 13, 30  
T2"  
PRINT USING "######.# ######.#"; DEC; DEC1  
E$ = INKEY$  
IF E$ = "" THEN  
GOTO ST2  
END IF  
GOTO ST1  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Transmit and Receive Comammand Summary  
1. Control letter should use Capital Letter.  
Baud rate: 1200  
Parity check: EVEN  
Data bits: 7  
Stop bits: 1  
"A" Activate data transmission  
"B" Stop data transmission  
"C" °C/°F Key  
"D"  
"
" Key  
"E" HOLD Key  
"F" TYPE Key  
"G" MIN/MAX Key  
"H" Exit record mode  
" I " T1 Key  
"J" T2 Key  
"K" T1-T2 Key  
"L" REL Key  
"M" Hi/Lo LIMITS Key  
"P" Turn off power of meter  
2. If you write you own program, the host computer must send the "A" letter to  
activate data transmission.  
3. If you should stop data transmission the host computer must send the "B"  
letter to extend battery life.  
4. Communication Parameters  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OUTPUT DATA FORMATS  
The data format consists of 32 bytes.  
byte  
0
1
S
0
2
0
3
0
4
0
5
0
6
0
7
0
8
A
0
9
S
1
0
1
1
1
2
1
3
1
4
1
5
1
6
A
1
7
1
8
1
9
2
0
2
1
2
2
2
3
A
2
4
A
2
5
2
6
A
2
7
A
2
8
A
2
9
A
3
0
A
3
1
3
2
CR nl  
H
H
H
H
H
H
H
H
H
H
H
H
D
D
D
D
D
D
A
T1 present status  
T2 present status  
Timer  
Meter status  
S: Negative sign or positive sign  
H: Hexadecimal digits  
D: Numeric digits  
A: Capital Letter or "-" sign  
CR: Carriage return character  
nl: newline character  
01  
09  
T1 polarity  
T2 polarity  
"+" Positive  
" Negative  
Values=[H07x160+H06x161+H05x162  
+H04x163+H03x164+H02x165] / 1000  
Values=[H15x160+H14x161+H13x162  
+H12x163+H11x164+H10x165] / 1000  
"
-
02 — MSD  
07 — LSD  
10 — MSD  
15 — LSD  
T
1
T
2
08 — Thermocouple Type  
"K" ® K type  
"J" ® J type  
"T" ® T type  
"E" ® E type  
"S" ® S type  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16 — none  
17 — MSD  
18 — LSD  
19 — MSD  
20 — LSD  
21 — MSD  
22 — LSD  
— "-"  
(H)ours  
(M)inutes  
(S)econds  
Time=INT[(Hx3600+Mx60+S)/2]  
23 — Record mode  
"R"  
"M"  
" I "  
"A"  
"-"  
®
®
®
®
®
®
®
®
®
Record mode  
MAX mode  
MIN mode  
AVG mode  
MAX-MIN mode  
normal mode  
Relative mode  
HOLD mode  
normal mode  
"
-"  
24 — REL & HOLD  
mode  
"R"  
"H"  
"
"
-
-
"
"
25 — none  
26 — LIMITS mode  
"L"  
®
®
®
®
®
®
Limits mode  
normal mode  
Hi Limits  
normal mode  
Lo Limits  
"
-"  
27 — Hi LIMITS  
28 — Lo LIMITS  
"H"  
"
-
"
"L"  
"
"
-
-
"
"
normal mode  
29 — none  
30 — Battery status  
"B"  
®
®
Low battery  
normal mode  
"
-
"
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMMUNICATION  
4612-IR232  
RS232C CABLE  
508BR  
1. Install the RSR232C cable between computer "COM1" and Thermometer  
RS232C port.  
2. Turn on Thermometer.  
3. Utilize the Quick BASIC for inputting programs.  
4. Use the capital control letter and input "A" letter from the keyboard to start  
sending messages to computer.  
5. Input "C" letter from the keyboard and then you can change the temperature  
scale.  
6. Input "F" letter from the keyboards and then you can circulating select the T1  
input type.  
7. Input "G" letter from the keyboard and then the meter enter record mode, and  
then you can push "G" again to circulate through Maximum/Minimum/Average/  
Record mode.  
8. When you want to stop transmission mode you should push "B" letter from the  
keyboard in order to conserve battery life.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HH501(A,B)K / HH501(A,B)J / HH501(A,B)T / HH501(A,B)E  
HH508BR/HH508/HH509/HH509R  
CALIBRATION PROCEDURE  
Note: The following calibration procedure should perform only by qualified technicians  
who have access to the items as following.  
Equipment: The class of calibrator had better 10 times greater than the measured meter.  
1. Set the jumper position on J1 position.  
2. Input DCV 25.6mV to the T1 after the display is stabilized (forward 4 digits), then  
press “ ENTER “ key and "01" is displayed.  
3. Input DCV 74mV after the display is stabilized, then press “ENTER “ key and "OL"  
is displayed.  
4. Input 0LC (K-type) after the display is stabilized, then press “ENTER “ key.  
5. Don't push any key and the meter will turn off automatically after 10 seconds.  
6. After adjustment set the jumper back to J3 position.  
7. Turn on the meter then input 0LC (K-type). The display reading reads 0°C if  
the calibration procedure is right.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY / DISCLAIMER  
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months  
from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product  
warranty to cover handling and shipping time.This ensures that OMEGA's customers receive maximum coverage on each product.If  
the unit should malfunction, it must be returned to the factory for evaluation. OMEGA's Customer Service Department will issue an  
Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to  
be defective it will be repaired or replaced at no charge. OMEGA's WARRANTY does not apply to defects resulting from any action  
of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair,  
or unauthorized modification.ThisWARRANTY isVOID if the unit shows evidence of having been tampered with or shows evidence  
of being damaged as a result of excessive corrosion; or current, heat moisture or vibration; improper specification; misapplication;  
misuse or other operating conditions outside of OMEGA's control. Components which wear are not warranted, including but not  
limited to contact points, fuses, and triacs.  
OMEGA is pleased to offer suggestions on the use of its various products. However,OMEGA neither assumes responsibility  
for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance  
with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it  
will be as specified and free of defects. OMEGA MAKES NO OTHERWARRANTIES OR REPRESENTATIONS OF ANY KIND  
WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY  
WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.  
LIMITATION OF LIABILITY:The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with  
respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall  
not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for  
consequential, incidental or special damages.  
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a "Basic Component" under 10  
CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any  
Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way,  
OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and additionally, purchaser will  
indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in  
such a manner.  
RETURN REQUESTS / INQUIRIES  
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY  
PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA'S  
CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then  
be marked on the outside of the return package and on any correspondence.  
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.  
FOR WARRANTY RETURNS, please have the following  
information available BEFORE contacting OMEGA:  
1. P.O. number under which the product was PURCHASED.  
FOR NON-WARRANTY REPAIRS, consult OMEGA for  
current repair charges. Have the following information  
available BEFORE contacting OMEGA:  
2. Model and serial number of the product under warranty, and 1. P.O. number to cover the COST of the repair.  
3. Repair instructions and/or specific problems relative to the  
product.  
2. Model and serial number of product , and  
3. Repair instructions and/or specific problems relative to the  
product.  
OMEGA's policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest  
in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 1999 OMEGA ENGINEERING,  
INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or  
machine-readable from, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Whe re Do I Find Eve rything I Ne e d for  
Proc e ss Me a sure m e nt a nd Control?  
OMEGA...Of Course !  
TEMPERATURE  
DATA ACQUISITION  
þ Data Acquisition &  
Engineering Software  
þ Communications-Based  
Acquisition Systems  
þ Plug-in Cards for Apple, IBM  
& Compatibles  
þ Thermocouple, RTD & Thermistor  
Probes, Connectors, Panels & Assemblies  
þ Wire: Thermocouple, RTD & Thermistor  
þ Calibrators & Ice Point References  
þ Recorders, Controllers & Process Monitors  
þ Infrared Pyrometers  
þ Datalogging Systems  
þ Recorders, Printers & Plotters  
PRESSURE/ STRAIN AND FORCE  
þ Transducers & Strain Gauges  
þ Load Cells & Pressure Gauges  
þ Displacement Transducers  
HEATERS  
þ Heating Cable  
þ Instrumentation & Accessories  
þ Cartridge & Strip Heaters  
þ Immersion & Band Heaters  
þ Flexible Heaters  
FLOW/ LEVEL  
þ Rotameters, Gas Mass Flowmeters  
& Flow Computers  
þ Laboratory Heaters  
ENVIRONMENTAL  
þ Air Velocity Indicators  
þ Turbine/Paddlewheel Systems  
þ Totalizers & Batch Controllers  
MONITORING AND CONTROL  
þ Metering & Control Instrumentation  
þ Refractometers  
p H/ CONDUCTIVITY  
þ Pumps & Tubing  
þ pH Electrodes, Testers & Accessories  
þ Benchtop/Laboratory Meters  
þ Controllers, Calibrators, Simulators  
& Pumps  
þ Air, Soil & Water Monitors  
þ Industrial Water & Wastewater  
Treatment  
þ pH, Conductivity & Dissolved Oxygen  
Instruments  
þ Industrial pH & Conductivity Equipment  
M-3203/0799  
Download from Www.Somanuals.com. All Manuals Search And Download.  

NEC Printer 2060 User Manual
Nilfisk ALTO Vacuum Cleaner 12 PE EC User Manual
Nokia Car Satellite TV System Nseries User Manual
Oki Printer 12i User Manual
Omega Vehicle Security Stud Sensor PX548
One for All Universal Remote Little Easy User Manual
Onkyo DVD Player DV SP402E User Manual
Onkyo Portable Speaker D 407M User Manual
Oster Toaster 118341 User Manual
Panasonic Camera Lens DMW GCK1GU User Manual