Magmeter
Download from Www.Somanuals.com. All Manuals Search And Download.
Omega FMG-3000 Series Magmeter
Topic:
Page
Topic:
Page
5
1. Quick Start Guide
2. Specifications
1
2
3
3
4
6. General Installation & Grounding Tips
7. Wiring the Magmeter with 4-20 Loop out
8. Wiring the Magmeter with freq. out
9. Calibration Data
5
3. Installation Pipe Fittings
4. Selecting a Location
5. FMG-3000 Magmeter Configuration
6
6-10
11
10. Maintenance & Troubleshooting
11. Ordering Information
12
1. Quick Start Guide
This manual contains the general installation, wiring and calibration data for the Omega FMG-3000 Series Magmeter with Frequency or
Current output. The basic steps are outlined on this page. See each referenced section for detailed information.
1. Position the PIPE SIZE Jumper according
to your pipe size. Sec. 5 Pg. 4
3.
Connect output signals and power
to this 4-terminal block.
FREQUENCY OUT
DO NOT REMOVE
4
3
2
1
1.
Sensor Type
Pipe Size
Jumper Position
½ in. to 2½ in.
DN15 to DN65
2. Install the Magmeter into the pipe.
Use Omega installation fittings ONLY.
The installation fitting is critical to
FMG3001
FMG3002
3 in. to 4 in.
DN80 to DN100
Magmeter performance. Sec. 3-4, Pg. 3
FMG3101
FMG3102
5 in. to 6 in.
DN125 to DN150
8 in.
DN200
4.
3.
FMG3201
FMG3202
10 in. to 12 in.
DN250 to DN300
3. Connect POWER and OUTPUT wiring.
FMG-3001 and FMG-3101 Frequency out:
Sec. 8.1 Pg. 6
2.
FMG3002 and FMG-3102 Current out wiring:
Sec. 7 Pg. 5
GROUNDING
Without a good Earth Ground, the Magmeter
may not operate efficiently. Sec. 6 Pg. 5
4. Route the wiring out through the two
cable ports. Use appropriate hardware
to secure the FMG-3000 from moisture
intrusion. One Liquid Tight Connector
is included. Sec. 5-6 Pg 4-5
1
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY INSTRUCTIONS
1. Depressurize and vent system prior to installation or removal.
2. Confirm chemical compatibility before use.
3. Do not exceed maximum temperature/pressure specifications.
4. Wear safety goggles or face shield during installation/service.
5. Do not alter product construction.
6. Disconnect power before attempting any service or wiring.
2. Specifications
Wetted Materials:
•
Sensor body, electrodes and grounding ring:
•
•
-PP: Polypropylene and 316L Stainless Steel
-PVDF and 316L Stainless Steel
psi
bar
14
Pressure vs. Temperature
•
O-rings:
FPM standard
EPDM, Kalrez® optional
200
Other materials:
•
•
Case:
Ground terminal:
PBT
160
120
80
11
8
316 Stainless Steel
Power Requirements
•
4 to 20 mA:
21.6 to 26.4 VDC, 22.1 mA maximum
400 mV p-p maximum ripple voltage
6
3
FMG-3000 series
Operating
•
•
Frequency:
Reverse polarity and short circuit protected
4.5 to 26.4 VDC, 15 mA maximum
Range
40
Performance
•
Pipe size range:
FMG-3000: ½ in. to 4 in.
FMG-3100: 5 in. to 8 in.
FMG-3200: 10 in. to 12 in.
Minimum: 0.05 m/s (0.15 ft/s)
Maximum: 10 m/s (33 ft/s)
(1% reading + 0.01 m/s)
(1% reading + 0.033 ft/s)
0.5% of reading @ 25°C
°F
0
40
4
80
27
120
49
160
71
200
93
240
115
•
•
Flow Range
Linearity:
-18
°C
Media Temperature
Max. operating pressure:
10.3 bar @ 25°C (150 psi @ 77°F)
1.4 bar @ 85°C (20 psi @ 185°F)
•
•
Repeatability
Minimum Conductivity: 20 µS/cm
Output Specifications
Current output (4 to 20 mA)
Tests, Approvals & Standards
•
•
Programmable and reversible
•
•
NEMA 4X
Loop Accuracy:
32 µA max. error
CE
(@ 25°C @ 24 VDC)
1 µA per °C max.
EN 61326: Immunity and Emissions for Control Equipment
•
•
•
Temp. drift:
Power supply rejection: 1 µA per V
Isolation: Low voltage <48 VAC/DC
Dimensions
from electrodes and auxiliary power
300 m (1000 ft.)
•
•
•
Maximum cable:
94 mm/
3.7 in.
Maximum Loop Resistance:
300 Ω
Error condition:
22.1 mA
Frequency output:
•
•
•
•
•
•
Max. Pull-up Voltage:
30 VDC
Short Circuit Protected: ≤30 V @ 0Ω pull-up for one hour
Reverse Polarity Protected -40 V
171 mm
6.73 in.
138 mm
5.43 in.
Overvoltage Protected to 40 V with pullup resistor
Max. Current Sink:
Maximum cable:
50 mA, current limited
300 m (1000 ft.)
Environmental Requirements
•
•
•
Storage Temperature: -20°C to 70°C (-4°F to 158°F)
Relative Humidity:
Operating Temperature
Ambient:
0 to 95% (noncondensing)
FMG-3000 series
Magmeter
for ½ in. to 4 in. pipe
FMG-3000 series
Magmeter
for 5 to 8 in. pipe
-10° to 70°C (14°F to 158°F)
0° to 85°C (32°F to 185°F)
Media:
2
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation: Pipe fittings
Omega offers a wide selection of installation fittings that control the position of the Magmeter electrodes in relation to the dimensions of
the pipe. You will find a complete list of order numbers for installation fittings in the Calibration tables on pages 9-13.
Type
Description
Type
Description
0.5 to 2 in. versions
Mounts on threaded pipe ends
Iron, Carbon Steel,
316 SS Threaded
tees
Plastic tees
0.5 to 4 inch versions
PVC or CPVC
Metric
Union
Fitting
Carbon steel &
stainless steel
Weld-on
2 to 4 inch, cut 1-7/16 inch hole in pipe
Over 4 inch, cut 2-1/8 inch hole in pipe
For pipes from DN 15 to 50 mm
PP or PVDF
Weldolets
PVC
Saddles
2 to 4 inch, cut 1-7/16 inch hole in pipe
6 to 8 inch, cut 2-1/8 inch hole in pipe
Fiberglass
tees &
saddles:
1.5 in. to 8 in. PVDF insert
> 8 in. PVC insert
FPT
FPS
Iron
Strap-on
saddles
2 to 4 inch, cut 1-7/16 inch hole in pipe
Over 4 inch, cut 2-1/8 inch hole in pipe
Metric
Wafer Fitting
For pipes DN 65 to 200 mm
PP or PVDF
4. Selecting a Location
•
•
The FMG-3000 requires a full pipe and a fully developed turbulent flow profile for accurate measurement.
If the piping system harbors air pockets or bubbles, take steps to locate the sensor so the air pockets will not contact the
electrodes.
In vertical installations, assemble the unit so the conduit ports are facing downward. This prevents condensation inside the conduit
from being directed into the electronics housing.
•
Inlet
Outlet
5 x I.D.
Flange
Reducer
90° Elbow
15 x I.D.
5 x I.D.
10 x I.D.
20 x I.D.
5 x I.D.
Select a location with sufficient
distance of straight pipe immediately
upstream of the sensor.
2 x 90° Elbow
3 dimensions
2 x 90° Elbow
Valve/Pump
25 x I.D.
5 x I.D.
40 x I.D.
5 x I.D.
50 x I.D.
5 x I.D.
Locating the sensor in a trap or where the
flow is upward helps to protect the sensor
from exposure to air bubbles when the
system is in operation.
NOTE: The system must be designed to
keep the sensor wet at all times.
O.K.
O.K.
O.K.
Vertical flow is OK IF the pipe remains full at all times.
These configurations are not
recommended because it is difficult to
keep the pipe full.
In a gravity-flow system, the tank must be designed
so the level does not drop below the outlet.
This causes the pipe to draw air in from the tank.
If air bubbles pass across the Magmeter electrodes,
the output will become erratic.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
5. FMG-3000 Magmeter Configuration
Whether using the FMG-3000 (frequency or 4-20 mA output) the wiring terminals located on the inside of the yellow cover are identical.
All of the connections from the Magmeter to external equipment (Datalogger, Chart Recorder, Flow meter, etc.) are made at the large
4-position terminal connector.
When the cover is removed the wiring from the sensor can be seen connected to the smaller terminal block. These connections should
always remain connected to prevent inadvertent damage or miswiring.
The terminals on the FMG-3000 Magmeter are designed for conductors from 16 AWG to 22 AWG.
Connect output cables to
JP2 is for factory use only.
this 4-terminal block.
MAKE NO CONNECTIONS.
This blue jumper must
Blue
Brown
Black
Red
Yellow
White
Not used
be in place for the
The factory connects
the sensor cable to the terminals
inside the yellow cover.
4
magmeter to operate
correctly.
3
2
1
Set this blue jumper
according to the pipe size.
½ in. (DN15)
¾ in. (DN20)
1 in. (DN25)
1¼ in. (DN32)
1½ in. (DN40)
2 in. (DN50)
2½ in. (DN65)
5 in. (DN125)
6 in. (DN150)
10 in. (DN250)
12 in. (DN300)
WARNING!
If the second conduit port is used,
carefully drill the opening. (The plastic
is too strong to be punched out.)
External Earth Ground Terminal
•
Secure the Magmeter in a vise to
prevent damage or injury.
The plastic inside the port is very
thin. Do not allow the drill to
penetrate too deeply and damage
the Magmeter wiring.
•
3 in. (DN80)
4 in. (DN100)
8 in. (DN200)
Flow
FP-LTC
Liquid tight connector
(one supplied)
Use the yellow decal to mark
the direction of flow on the pipe
Flow
Sensor grounding ring
Important:
•
•
•
•
•
The directional arrow on the body of the sensor must be pointed DOWNSTREAM.
The FLOW arrow decal can be placed directly on the pipe to identify the direction of flow.
Use a cable gland or a liquid tight connector to seal the cable ports from water intrusion.
The yellow housing may be reversed to align the conduit ports as required.
If the Magmeter is installed on a vertical pipe, the conduit ports should be turned to point downward.
This will prevent condensation from being channeled into the enclosure.
Use plumber's tape or a suitable sealant on cable ports.
•
4
Download from Www.Somanuals.com. All Manuals Search And Download.
6. General Installation and Grounding Tips
Sensor conditioning
The Magmeter output signal may be unstable immediately after installation. Allowing the sensor to soak in a full pipe (or in any
container of water) for 24 hours will stabilize the performance.
•
Very low conductivity fluids may require a longer conditioning period. (The Magmeter may not operate properly in fluids where the
conductivity is less than 20 µS/cm.)
Grounding
The FMG-3000 Magmeter is unaffected by moderate levels of electrical noise. However, in some applications it may be necessary to
ground portions of the system to eliminate electrical interference. The grounding requirements will vary with each installation.
One or more of the following steps may be
applied if the FMG-3000 Magmeter is affected by
electrical noise:
Do not terminate
shield at Magmeter
3.
1.
ꢀ The ground terminal on the outside of the
yellow housing is connected internally
to the grounding ring at the tip of the
sensor. Connect a wire (14 AWG/1.5 mm2
recommended) from this terminal directly to a
local Earth ground.
Instrument
4.
Sensor
Grounding ring
ꢁ Install fluid grounding devices immediately
upstream and downstream of the Magmeter.
Connect the fluid grounds to the Earth ground
terminal on the FMG-3000.
Earth ground
Use flanged grounding rings or metal
electrodes on plastic pipes, or metal clamps
on metal pipes.
Fluid grounds must be in direct contact with
the fluid, and as near to the Magmeter as
possible.
4 in. to 50 in.
4 in. to 50 in.
(10 cm to 1.3 m)
(10 cm to 1.3 m)
ꢂ The shield from the output cable must be
terminated at the remote instrument ONLY.
This shield must not be connected at both
ends!
Grounding rings on plastic pipe
2.
2.
(Install between flanges)
or
metal straps on metal pipe
ꢃ Connect an additional wire (minimum AWG
14/1.5 mm2) from the remote instrument ground to the Magmeter ground terminal.
7. Wiring the FMG-3002 and FMG-3102 Magmeter with 4-20 mA Loop Output
The FMG-3002 and FMG-3102 Magmeters are traditional 2-wire passive 4-20 mA loop transmitters.
•
•
•
External loop power (24 VDC 10%) is required.
The maximum loop resistance the Magmeter can accomodate is 300 Ω.
All FMG-3002 and FMG-3102 Magmeters are shipped from the factory with the 4-20 mA output scaled for 0 to 5 m/s (0 to 16.4 ft/s).
The Calibration charts on pages 6-10 list the 20 mA setpoint for each installation fitting. Use this information to program the 4-20
mA range of the loop device (PLC, Datalogger, recorder, etc.)
FMG-3000 Series Magmeter
4
4-20 mA Loop
monitor
Loop - (Ground)
3
2
1
-
-
+
+
(Maximum 300 Ω)
Loop + (24 VDC)
24 VDC 10%
5
Download from Www.Somanuals.com. All Manuals Search And Download.
8. Wiring the FMG-3001 and FMG-3101 with Frequency output
•
•
The FMG-3001 and FMG-3101 Magmeters output an open collector frequency signal.
A 10 KΩ pull up resistor must be connected between terminals 1 and 2 if the magmeter is used with third-party equipment..
Blue Jumper
ON
Connect AUX power on
the FP90 to provide the
power to the FMG3000
OPEN COLLECTOR
output.
Magmeter
FP90 Flow Transmitter
Not used
Ground
4
3
Frequency
Sensr Gnd
9
8
7
(SHIELD)
4
3
Frequency
Sensr IN
(RED)
2
1
5-24 VDC
Sensr V+
(BLACK)
Magmeter
Not used
Ground
4
3
Frequency Out
5-24 VDC
2
1
Install a pull-up resistor when connecting the
Magmeter to other manufacturer's flowmeters.
9. Calibration Data: K-factors* and Full Scale Current Values
Metal Installation Fittings
Iron Saddles
PIPE SIZE
(IN.)
FITTING
TYPE
K-Factor
Gallons
K-Factor
Liters*
20 mA=
in GPM
20 mA=
in LPM
SCH 80 IRON SADDLE ON SCH 80 PIPE
2
FP-5320GI
FP-5325GI
FP-5330GI
FP-5340GI
FP-5350GI
FP-5360GI
FP-5380GI
FP-5381GI
FP-5382GI
194.85
142.28
87.53
40.62
29.28
22.30
12.52
7.94
51.48
37.59
23.13
10.73
7.74
153.96
210.86
342.72
738.58
1024.43
1345.58
2395.41
3778.75
5311.45
582.75
2½
3
798.10
1297.20
2795.54
3877.48
5093.03
9066.64
14302.5
20103.8
4
5
6
5.89
8
3.31
10
12
2.10
5.65
1.49
SCH 80 IRON SADDLE ON SCH 40 PIPE
2
FP-5320GIS
FP-5325GI
FP-5330GI
FP-5340GI
FP-5350GI
FP-5360GI
FP-5380GI
FP-5381GI
FP-5382GI
185.35
127.47
76.62
40.23
27.32
19.71
11.61
7.36
48.97
33.68
20.24
10.63
7.22
161.85
235.36
391.54
745.72
1098.24
1521.92
2584.23
4078.8
5793.39
612.61
2½
3
890.83
1481.99
2822.57
4156.83
5760.46
9781.30
15438.2
21927.9
4
5
6
5.21
8
3.07
10
12
1.94
5.18
1.37
6
Download from Www.Somanuals.com. All Manuals Search And Download.
9. Calibration Data: K-factors* and Full Scale Current Values
Plastic Installation Fittings: PVC Tees and Saddles
PIPE SIZE
(IN.)
FITTING
TYPE
K-Factor
Gallons
K-Factor
Liters*
20 mA=
in GPM
20 mA=
in LPM
SCH 80 PVC TEES FOR SCH 80 PVC PIPE
½
¾
1
FP-5305
FP-5307
FP-5310
FP-5312
FP-5315
FP-5315
FP-5325
FP-5330
FP-5340
2289.37
1430.41
876.86
447.06
324.19
206.69
131.46
82.52
604.85
377.92
231.67
118.11
85.65
54.61
34.73
21.80
11.83
13.10
20.97
34.21
67.10
92.54
145.15
228.20
363.55
669.88
49.60
79.38
129.50
253.99
350.25
549.38
863.74
1376.04
2535.49
1¼
1½
2
2½
3
4
44.78
SCH 80 PVC TEES FOR SCH 80 CPVC PIPE
½
FP-5305C
FP-5307C
FP-5310C
FP-5312C
FP-5315C
2496.03
1381.48
857.98
445.17
325.56
659.45
364.99
226.68
117.61
86.01
12.02
21.72
34.97
67.39
92.15
45.49
¾
82.19
1
132.34
255.07
348.78
1¼
1½
SCH 80 PVC SADDLES FOR SCH 80 PVC PIPE
2
FP-5320S
FP-5325S
FP-5330S
FP-5340S
FP-5360S
FP-5380S
FP-5381S
FP-5382S
193.83
138.01
83.89
40.88
22.53
12.52
7.94
51.21
36.46
22.16
10.80
5.95
154.77
217.38
357.62
733.88
1331.85
2395.41
3778.75
5256.69
585.81
2½
3
822.78
1353.60
2777.74
5041.06
9066.64
14302.57
19896.57
4
6
8
10
12
3.31
2.10
1.51
5.71
SCH 80 PVC SADDLES FOR SCH 40 PVC PIPE
2
FP-5320S
FP-5325S
FP-5330S
FP-5340S
FP-5360S
FP-5380S
FP-5381S
FP-5382S
180.01
123.72
75.81
41.87
19.71
11.73
7.43
47.56
32.69
20.03
11.06
5.21
166.66
242.49
395.71
716.56
1521.92
2558.12
4037.60
5734.87
630.81
2½
3
917.82
1497.76
2712.19
5760.46
9682.50
15282.3
21706.48
4
6
8
10
12
3.10
1.96
1.38
5.23
7
Download from Www.Somanuals.com. All Manuals Search And Download.
9. Calibration Data: K-factors* and Full Scale Current Values
Plastic Installation Fittings for Metric Pipes:
Polypropylene True Union Tees and Wafers
PVDF True Union Tees and Wafers
PVC True Union Tees and Wafers
PIPE SIZE
(IN.)
FITTING
TYPE
K-Factor
Gallons
K-Factor
Liters*
20 mA=
in GPM
20 mA=
in LPM
POLYPROPYLENE FITTINGS (DIN/ISO ,BS, ANSI)
½
FP-5105PO
FP-5107PO
FP-5110PO
FP-5112PO
FP-5115PO
FP-5120PO
2192.73
1327.81
737.16
453.46
275.03
156.87
579.32
350.81
194.76
119.81
72.66
13.68
22.59
40.70
66.16
109.08
191.24
51.78
¾
85.52
1
154.04
250.41
412.86
723.83
1¼
1½
2
41.45
PVDF FITTINGS (DIN/ISO ,BS, ANSI)
½
FP-5105
FP-5107
FP-5110
FP-5112
FP-5115
FP-5120
1946.49
1158.05
749.09
439.51
248.93
146.85
514.26
305.96
197.91
116.12
65.77
15.41
25.91
40.05
68.26
120.52
204.30
58.34
¾
98.05
1
151.58
258.36
456.16
773.26
1¼
1½
2
38.80
8
Download from Www.Somanuals.com. All Manuals Search And Download.
9. Calibration Data: K-factors* and Full Scale Current Values
Metal Installation Fittings:
Carbon Steel Tees and Weld-o-Lets
Stainless Steel Tees and Weld-o-Lets
Galvanized Iron Tees
PIPE SIZE
(IN.)
FITTING
TYPE
K-Factor
Gallons
K-Factor
Liters*
20 mA=
in GPM
20 mA=
in LPM
CARBON STEEL TEES ON SCH 40 PIPE
½
FMG-5305CS
FMG-5307CS
FMG-5310CS
FMG-5312CS
FMG-5315CS
FMG-5320CS
1572.66
1086.73
582.34
377.48
267.79
167.85
415.50
287.11
153.86
99.73
19.08
27.61
51.52
79.48
112.03
178.73
72.20
¾
104.49
194.99
300.81
424.02
676.48
1
1¼
1½
2
70.75
44.35
STAINLESS STEEL TEES ON SCH 40 PIPE
½
FMG-5305
FMG-5307
FMG-5310
FMG-5312
FMG-5315
FMG-5320
1601.26
937.78
606.18
279.68
147.65
111.90
423.05
247.76
160.15
73.89
18.74
70.91
¾
31.99
121.08
187.32
405.99
769.06
1014.73
1
49.49
1¼
1½
2
107.26
203.19
268.09
39.01
29.56
STAINLESS STEEL WELDOLETS ON SCH 40 PIPE
2½
3
FMG-5325
FMG-5330
FMG-5340
FMG-5350
FMG-5360
FMG-5380
FMG-5381
FMG-5382
106.31
72.27
36.84
29.28
20.29
11.73
7.45
28.09
19.09
9.73
7.73
5.36
3.10
1.97
1.39
282.19
1068.10
1571.25
3082.28
3878.50
5595.21
9680.96
15249.1
21660.5
415.12
4
814.34
4
1024.70
1478.26
2557.72
4028.83
5722.73
4
8
10
12
5.24
CARBON STEEL WELDOLETS ON SCH 40 PIPE
2½
3
FMG-5325CS
FMG-5330CS
FMG-5340CS
FMG-5350CS
FMG-5360CS
FMG-5380CS
FP-5381CS
105.70
70.68
36.38
29.28
20.29
11.73
7.45
27.93
18.67
9.61
7.73
5.36
3.10
1.97
1.39
283.82
1074.27
1606.56
3121.30
3878.50
5595.21
9680.96
15249.1
21660.5
424.45
4
824.65
4
1024.70
1478.26
2557.72
4028.83
5722.73
6
8
10
12
FP-5382CS
5.24
GALVANIZED IRON TEES ON SCH 40 PIPE
1
FP-5310GI
FP-5312GI
FP-5315GI
FP-5320GIS
558.50
334.45
248.97
146.00
147.56
88.36
65.78
38.57
53.71
203.31
339.51
456.07
777.76
1¼
1½
2
89.70
120.49
205.48
9
Download from Www.Somanuals.com. All Manuals Search And Download.
9. Calibration Data: K-factors* and Full Scale Current Values
Metal Installation Fittings:
Bronze and Copper Tees and Brazolets
PIPE SIZE
(IN.)
FITTING
TYPE
K-Factor
Gallons
K-Factor
Liters*
20 mA=
in GPM
20 mA=
in LPM
BRONZE TEES ON SCH 40 PIPE
1
FP-5310BR
FP-5312BR
FP-5315BR
FP-5320BR
582.34
330.54
254.76
157.36
153.86
87.33
67.31
41.58
51.52
194.99
343.53
445.71
721.58
1¼
1½
2
90.76
117.76
190.64
COPPER TEES FITTING ON COPPER PIPE SCH K
½
FP-5305CU
FP-5307CU
FP-5310CU
FP-5312CU
FP-5315CU
FP-5320CU
2459.19
1108.02
649.87
422.03
281.43
136.02
649.72
292.74
171.70
111.50
74.35
12.20
27.08
46.16
71.09
106.60
220.55
46.17
¾
102.48
174.73
269.06
403.47
834.78
1
1¼
1½
2
35.94
COPPER TEES FITTING ON COPPER PIPE SCH L
½
FP-5305CU
FP-5307CU
FP-5310CU
FP-5312CU
FP-5315CU
FP-5320CU
2406.30
1174.77
672.28
402.84
294.99
149.63
635.75
310.37
177.62
106.43
77.94
12.47
25.54
44.62
74.47
101.70
200.50
47.19
¾
96.66
1
168.90
281.87
384.92
758.89
1¼
1½
2
39.53
COPPER/BRONZE BRAZOLET ON SCH 40 PIPE
2½
3
FP-5325BR
FP-5330BR
FP-5340BR
FP-5350BR
FP-5360BR
FP-5380BR
FP-5381BR
FP-5382BR
117.31
78.62
45.13
32.79
22.73
13.14
8.34
30.99
20.77
11.92
8.66
255.74
381.58
664.77
914.91
1319.87
2283.68
3597.17
5109.58
967.96
1444.28
2516.15
3462.95
4995.72
8643.71
13615.29
19339.76
4
5
6
8
10
12
6.01
3.47
2.20
5.87
1.55
10
Download from Www.Somanuals.com. All Manuals Search And Download.
10. Maintenance
The FMG-3000 series Magmeter requires very little maintenance. There are no user-serviceable components in the Magmeter.
•
•
•
If the fluid contains deposits and solids that may coat the electrodes, a regular cleaning schedule is recommended.
Do not use abrasive materials on the metal electrodes. Clean with soft cloth and mild detergent only.
Use a cotton swab and mild detergent to remove deposits on the metal electrodes at the tip of the sensor.
10.1.
•
•
Environmental Recommendations:
When used properly, this product presents no inherent danger to the environment.
Please follow local ordinance when disposing of this or any product with electronic components.
10.2 Troubleshooting
Possible Cause
Possible Solution
Symptom
•
Frequency or Current
output is erratic.
•
•
Move the Magmeter upstream at least
10 pipe diameters from obstruction.
Clean the electrodes with soft cloth.
Do not use abrasives.
•
•
•
•
•
Magmeter installed too close to
upstream obstruction.
Magmeter electrodes are coated with
solids.
•
•
Eliminate air bubbles in the pipe.
Remove the Magmeter and reinstall
with the flow direction arrow on the
sensor body pointed DOWNSTREAM.
Modify grounding as required
to protect the Magmeter from
interference.
Magmeter electrodes exposed to air
bubbles/pockets.
Electrical noise is interfering with the
measurement.
•
•
New sensor, metal surface not
properly conditioned.
Soak sensor overnight in fluid.
•
•
Soak sensor overnight in fluid.
Configure pipe so electrodes are
always in fluid.
Modify grounding as required
to protect the Magmeter from
interference.
Set low flow cutoff higher.
Return to factory for service.
•
•
•
Electrode not adequately conditioned.
Pipe is empty, Magmeter is not in fluid.
Electrical noise is interfering with the
measurement.
•
•
Output is not 0 when flow is stopped.
•
•
Defective Magmeter
•
•
•
•
4-20 mA is not scaled same as Loop
device.
•
Respan Loop device to match
Magmeter.
Set Range Jumper correctly.
Return to factory for service.
4-20 mA output is incorrect.
Loop device is not scaled same as
Magmeter.
•
•
•
•
Range Jumper not placed correctly.
Defective Magmeter
•
•
Frequency model is FMG-3001 and
FMG-3101 series.
•
•
Frequency output is inoperative
Loop output is inperative.
•
•
•
•
FMG-3000 is wrong model.
Blue jumper not in correct position.
Wiring is not correct.
Place blue jumper correctly. (Sec. 5
pg. 9)
Frequency input to other
•
•
Check wiring, make corrections.
Install 10kΩ resistor. Sec 8.1, pg. 6)
manufacturer's flow instrument does
not have pull-up resistor.
•
•
Conductivity is less than 20 µS/cm.
Electronic component failure.
•
•
Unsuitable application for Magmeter.
Return to factory for service.
•
Output is 22.1 mA.
Troubleshooting with the RED and BLUE lights
The FMG-3000 uses two colored LEDs to indicate the status of the instrument.
They are located at the top of the magmeter, inside the clear plastic cap.
4
3
No Lights:
The power is off or the sensor is not connected
The power is on but there is no flow in the pipe.
Normal operation, blink rate is proportional to the flow rate.
Empty pipe indication (electrodes are not wet.)
System errors (Electrical noise interference)
2
Solid Blue (D7):
Blinking Blue (D7):
Alternating Red-Blue:
Blinking Red (D6):
Solid Red (D6):
1
D7
D6
Instrument error (defective electronics component)
Flow
Flow
11
Download from Www.Somanuals.com. All Manuals Search And Download.
11. Ordering Information
OMEGAMAG with Frequency Output
FMG3001-PP
FMG3101-PP
FMG3201-PP
OMEGAMAG, Blind, Freq, PP/316SS, ½-4
OMEGAMAG, Blind, Freq, PP/316SS, 5-8
OMEGAMAG, Blind, Freq, PP/316SS,10-12
FMG-3001-PVDF-HA
FMG3101-PVDF-HA
FMG3201-PVDF-HA
OMEGAMAG, Blind, Freq, PVDF/Hast, ½-4
OMEGAMAG, Blind, Freq, PVDF/Hast, 5-8
OMEGAMAG, Blind, Freq, PVDF/Hast,10-12
FMG-3001-PVDF
FMG3101-PVDF
FMG3201-PVDF
OMEGAMAG, Blind, Freq, PVDF/316SS, ½-4
OMEGAMAG, Blind, Freq, PVDF/316SS, 5-8
OMEGAMAG, Blind, Freq, PVDF/316SS,10-12
FMG-3001-PVDF-TI
FMG3101-PVDF-TI
OMEGAMAG, Blind, Freq, PVDF/Ti, ½-4
OMEGAMAG, Blind, Freq, PVDF/Ti, 5-8
OMEGAMAG with 4-20 mA Loop Output
FMG3002-PP
FMG3102-PP
FMG3202-PP
OMEGAMAG, Blind, Loop, PP/316SS, ½-4
OMEGAMAG, Blind, Loop, PP/316SS, 5-8
OMEGAMAG, Blind, Loop, PP/316SS, 10-12
FMG3002-PVDF-HA
FMG3102-PVDF-HA
FMG3202-PVDF-HA
OMEGAMAG, Blind, Loop, PVDF/Hast, ½-4
OMEGAMAG, Blind, Loop, PVDF/Hast, 5-8
OMEGAMAG, Blind, Loop, PVDF/Hast,10-12
FMG3002-PVDF
FMG3102-PVDF
FMG3202-PVDF
OMEGAMAG, Blind, Loop, PVDF/316SS, ½-4
OMEGAMAG, Blind, Loop, PVDF/316SS, 5-8
OMEGAMAG, Blind, Loop, PVDF/316SS,10-12
FMG3002-PVDF-TI
FMG3102-PVDF-TI
OMEGAMAG, Blind, Loop, PVDF/Ti, ½-4
OMEGAMAG, Blind, Loop, PVDF/Ti, 5-8
Replacement Parts and Accessories
FMG3000-VO
FMG3000-EO
FMG3000-KO
FP-LTC
O-ring, FPM (Viton®)
O-ring, EPDM
O-ring, FFPM (Kalrez®)
Liquid Tight Connector
12
Download from Www.Somanuals.com. All Manuals Search And Download.
MAD E
IN
USAA
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period
of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period
to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s
customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request.
Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,
including but not limited to mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of
having been tampered with or shows evidence of having been damaged as a result of excessive corrosion;
or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components which wear are not warranted, including but not
limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However,
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for
any damages that result from the use of its products in accordance with information provided
by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it
will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT
OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of
OMEGA with respect to this order, whether based on contract, warranty, negligence,
indemnification, strict liability or otherwise, shall not exceed the purchase price of the
component upon which liability is based. In no event shall OMEGA be liable for
consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity,
medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in
our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold
OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a
manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RE-
TURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR)
NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING
DELAYS). The assigned AR number should then be marked on the outside of the return package and on any
correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent break-
age in transit.
FOR WARRANTY RETURNS, please have the
following information available BEFORE
contacting OMEGA:
FOR NON-WARRANTY REPAIRS, consult OMEGA for
current repair charges. Have the following information
available BEFORE contacting OMEGA:
1. Purchase Order number under which the product
1. Purchase Order number to cover the COST of the
was PURCHASED,
repair,
2. Model and serial number of the product under
warranty, and
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems relative
to the product.
3. Repair instructions and/or specific problems relative
to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our
customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2000 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced,
translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of
OMEGA ENGINEERING, INC.
Download from Www.Somanuals.com. All Manuals Search And Download.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
TEMPERATURE
•
•
•
•
•
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
•
•
•
•
Transducers & Strain Gages
Load Cells & Pressure Gages
Displacement Transducers
Instrumentation & Accessories
FLOW/LEVEL
•
•
•
•
Rotameters, Gas Mass Flowmeters & Flow Computers
Air Velocity Indicators
Turbine/Paddlewheel Systems
Totalizers & Batch Controllers
pH/CONDUCTIVITY
•
•
•
•
pH Electrodes, Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
DATA ACQUISITION
•
•
•
•
•
Data Acquisition & Engineering Software
Communications-Based Acquisition Systems
Plug-in Cards for Apple, IBM & Compatibles
Datalogging Systems
Recorders, Printers & Plotters
HEATERS
•
•
•
•
•
Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
•
•
•
•
•
•
Metering & Control Instrumentation
Refractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, Conductivity & Dissolved Oxygen Instruments
6-2551.090-OM (C-4/07)
M-4210/0407
Download from Www.Somanuals.com. All Manuals Search And Download.
|