Olympus Microscope Magnifier CX41 User Manual

SYSTEM MICROSCOPE  
Olympus is about life. About photographic innovations that capture precious moments of life. About advanced  
medical technology that saves lives. About information- and industry-related products that make possible a better living.  
About adding to the richness and quality of life for everyone. Olympus. Quality products with a  
CX2 SERIES  
Optics and performance outstanding in its class  
UNIVERSAL  
INFINITY SYSTEM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Outstanding flat images from Plan C objectives  
The CX41 provides images of outstanding brightness and clarity in a variety of observation  
modes. As well as Olympus' renowned UIS optics infinity system, it employs the newly  
developed PLC series of Plan Achromat objectives, which are made from carefully selected  
top quality glass and manufactured with the most rigorous precision. The result is a major  
improvement in image flatness, with the 10x and 40x objectives in particular providing images  
that are among the very best in this class of microscope. Transmitted light illumination is  
from a 6V, 30W high-intensity halogen light source.  
Flatness area comparison  
10x  
40x  
F.N. 20  
F.N. 20  
Conventional  
objective  
Conventional  
objective  
PLC10x  
PLC40x  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Excellent cost-performance in reflected light fluorescence  
and other observation methods  
Simple phase contrast attachment /  
CX-PH1, 2, 3  
For phase-contrast observations at 10x,  
40x and 100x.  
Slide condenser / CX-SLC  
Darkfield central stop / CH2-DS  
Brightfield condenser / CH3-CD  
For darkfield observations from 4x to 40x.  
These Abbe type condensers allow  
* Separate filter holder (CH2-FH) or attachment lens (CX-AL)  
required.  
brightfield observations from 4x to  
100x. Accurate centering is provided  
by the attachment lens (CX-AL) and the  
iris diaphragm, to exclude unnecessary  
light and obtain bright Koehler  
illumination right across the  
magnification range. These highly  
economical condensers enable phase-  
contrast and darkfield observations by  
simply adding basic accessories.  
Low magnification adapter /CX-LA  
Use of the 2x low magnification objective allows  
macro observation.  
Reflected light fluorescence  
attachment / CX-RFL-2  
Simple polarizing condenser /  
CH3-CDP  
Users can swap between blue or green  
excitation and transmitted light  
With the optional plate adapter U-TAD,  
polarizing observations from 4x to 100x  
using a tint plate can be performed.  
A U-GAN analyzer is provided for gout  
inspection. Polarizing objectives from  
4x to 100x are  
observations. UIS optics provide bright  
fluorescence images, with no intermediate  
magnifications when changing from  
transmitted light to fluorescence  
observation. Standard PLC objectives can  
be used without replacement.  
available.  
* Separate polarizer  
U-POT and analyzer  
U-ANT required.  
Dry darkfield condenser / CX-DCD  
This dry-type darkfield condenser gives a  
superior darkfield effect without the need for  
immersion in oil.  
Suitable for use  
at 10x and 40x  
magnifications.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dependable basic performance assures  
outstanding operational convenience  
Move the specimen with just one finger  
Rubber grips are provided for the stage  
handles, allowing the specimen to be moved  
smoothly with just one finger. The slim body  
and conveniently positioned controls ensure  
that everything is within easy reach, so  
operators can maintain a natural posture.  
Tilting binocular tube  
The tilting binocular tube lets each operator  
select the most suitable and comfortable  
eyepoint a valuable contribution to  
reducing fatigue in extended observation  
sessions.  
Inward-facing quintuple revolving  
nosepiece  
Rackless stage with enhanced operability  
To keep the work area clear, and to avoid  
interference with observation operations,  
the X-direction travel guide does not extend  
out from the side of the stage. The main and  
sub scale displays are designed for easy  
read-out.  
The quintuple revolving nosepiece enables a  
wide range of magnification observations  
and various combinations of objectives.  
Unrestricted access to the space in front of  
the objective allows specimens to be  
exchanged quickly and easily.  
Phase-contrast condenser / CX-PCD  
The multi-purpose CX-PCD condenser  
allows observation of brightfield, phase-  
contrast and darkfield images without  
exchanging condensers. Phase-contrast  
observation from  
Torque adjustable focusing knob  
Easy transportation and installation  
The CX41 is eminently portable, with  
convenient handgrips at the front and back  
of the frame and no sudden, inconvenient  
protrusion of the stage guide.  
10x to 100x and  
The torque of the coarse focusing knob can  
be adjusted, to suit different operators' needs  
and to make focusing smooth and easy while  
keeping the hands on the desk. A stage  
upper limit stopper is also provided.  
darkfield  
observation from  
10x to 40x is  
allowed.  
Anti-fungus treatment  
The treatment applied to the  
observation tubes, eyepieces and  
objectives, protects quality of optical  
parts even in high humidity regions.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
More accessories, more observation versatility  
Easy digital imaging  
A simple eyepiece adapter enables an  
Olympus digital camera to be attached to  
binocular tube U-CBI30-2 an easy,  
practical and cost-efficient means of  
obtaining digital images.  
Eyepoint adjuster / U-EPA2  
Allows the eyepoint position to be raised by  
30mm. Up to two eyepoint adjusters can  
be attached between the frame arm and  
observation tube.  
Dual observation attachment / U-DO3  
Enables dual, simultaneous observation of  
a single specimen from the same direction  
with equal magnification and brightness for  
both operators. A pointer can be used to  
indicate specific sections of the specimen to  
simplify the training process and promote  
discussion.  
Arrow pointer / U-APT  
Enables insertion of an LED arrow for  
display in a photomicrograph.  
2x magnification changer / U-ECA  
Magnification is doubled by engaging the  
auxiliary 2x lens.  
Trinocular tube / U-CTR30-2  
Still digital (DP11) or video cameras can  
be attached for on-site/remote illustration  
of educational/discussion meetings.  
Trinocular intermediate attachment /  
U-TRU  
A binocular tube on its own allows  
photomicrography. Combination with  
this intermediate attachment type  
trinocular tube makes it possible to attach  
photographic equipment and a video  
camera at the same time.  
Drawing attachment / U-DA  
The drawing attachment projects an image  
of the pencil and drawing surface into the  
visual field.  
U-DA  
CX41+DP11  
U-DAL10x  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Item  
CX41  
Optical system  
Illumination  
UIS (Universal Infinity-corrected) optical system  
Built-in transmitted Koehler illuminator  
6V30W halogen bulb  
100-120V/220-240Vg 0.85/0.45A 50/60Hz  
Focusing  
Stage height movement by roller guide (rack & pinion) Stroke per rotation: 36.8mm  
Full stroke range: 25mm Upper limit stopper Tension adjustment on coarse focus adjustment knob  
Revolving nosepiece  
Observation tube  
Fixed quintuple nosepiece with inward tilt  
Type  
U-CBI30-2, Binocular  
U-CTR30-2, Trinocular  
Field number  
Tube inclination  
20  
20  
30º  
30º  
Interpupillary distance adjustment range 48-75mm  
48-75mm  
Light path selector  
Size  
None  
None (Bi 50%, Video/Photo 50% fixed)  
Stage  
188(W)x134(D)mm  
76mm X-direction x 50mm Y-direction  
Double slide holder  
Movement range  
Specimen holder  
Rubber grip  
Type  
Equipped as standard  
Abbe condenser, with built-in daylight filter  
1.25 with oil immersion  
Built-in  
Condenser  
N.A.  
Aperture iris diaphragm  
Dimensions & weight  
233(W)x432(H)x367.5(D)mm, approximately 8.5kg (approximately 18.7 lb.)  
Dimensions  
(Unit: mm)  
Objectives, Plan Achromat  
PLC  
Numerical Aperture Working Distance  
(N.A.)  
0.10  
0.25  
0.65  
1.25  
(W.D.)  
22.0mm  
10.5mm  
0.56mm  
0.13mm  
4x  
10x  
40x  
100xOil  
Eyepiece  
Field Number (F.N.)  
20  
WHB10x  
245  
160  
233  
* The length marked with an asterisk (*) may vary accoding to interpupillary distance. Distance for figure shown is 62mm.  
ISO14001  
Certification  
Certificate No. 961049  
ISO9001  
Certification  
Certificate No.69372  
Design and production at the Olympus  
Optical Co. Ltd. Ina Plant conforms with  
ISO14001 specifications for  
Design and production  
adheres to ISO9001  
internationalquality standard.  
Accredited by the  
Dutch Council for  
Accreditation  
ISO 9001  
ISO 14001  
environmental management systems.  
Specifications are subject to change without any obligation on the part of the manufacturer.  
San-Ei building, 22-2, Nishi Shinjuku 1-chome, Shinjuku-ku, Tokyo, Japan  
Postfach 10 49 08, 20034, Hamburg, Germany  
2 Corporate Center Drive, Melville, NY 11747-3157, U.S.A.  
491B River Valley Road, #12-01/04 Valley Point Office Tower, Singapore 248373  
2-8 Honduras Street, London EC1Y OTX, United Kingdom.  
104 Ferntree Gully Road, Oakleigh, Victoria, 3166, Australia  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Coffeemaker 9741510 User Manual
Milwaukee Cordless Drill LOK TOR II User Manual
Multi Tech Systems Network Card ISI3334 4 User Manual
National Instruments Network Card NI 9237 User Manual
NetComm Security Camera NS380W User Manual
Oregon Scientific Clock RM622P User Manual
Oregon Scientific Heart Rate Monitor SH201 User Manual
Oregon Scientific Radar Detector BAR908HG User Manual
Panasonic Noise Reduction Machine 0302 User Manual
Paragon Popcorn Poppers 1106300 User Manual