8000 Series I/O
Product Catalog
Page
Contents
Family Overview
4
Module Data Sheets
Analog Input Modules
8
9
ꢀ0
ꢀꢀ
ꢀꢂ
ꢀ4
• NT-8ꢀ0ꢀ-HI-TX 8-channel AI, 4-ꢁ0mA with HART for ꢁ- or 4-wire
• NT-8ꢀ0ꢂ-AI-TX 8-channel AI, 4-ꢁ0mA for ꢁ- or 4-wire
• NT-8ꢀꢀ9-VI-05 8-channel Voltage Input, ꢀ-5Vdc
• NT-8ꢀꢂꢁ-AI-UN 8-channel isolated AI, 4-ꢁ0mA with HART, Thermocouple, RTD,Voltage
• NT-8ꢀ05-TI-TC 4-channel THC/mV input
• NT-8ꢀ06-TI-RT 4-channel RTD input
Analog Output Modules
• NT-8ꢀ0ꢁ-HO-IP 8-channel AO, with HART for 4-ꢁ0mA
• NT-8ꢀ04-AO-IP 8-channel AO, 4-ꢁ0mA
ꢀ5
ꢀ6
Digital Inputs
ꢀ7
ꢀ8
ꢀ9
ꢁ0
ꢁꢀ
ꢁꢁ
ꢁꢂ
ꢁ4
• NT-8ꢀ09-DI-DC 8-Channel DI, ꢁ4VdC isolated, sinking
• NT-8ꢀꢀ0-DI-DC 8-channel DI, ꢁ4Vdc non-isolated, module powered
• NT-8ꢀꢁꢀ-DI-DC ꢀ6-channel DI, ꢁ4Vdc non-isolated, module powered
• NT-8ꢀꢁꢁ-DI-DC ꢀ6-channel DI, ꢁ4Vdc isolated, sinking
• NT-8ꢀꢀꢀ-DI-AC 8-channel DI, ꢀꢀ5Vac isolated, sinking
• NT-8ꢀꢀꢁ-DI-AC 8-channel DI, ꢀꢀ5Vac non-isolated, module powered
• NT-8ꢀꢀꢂ-DI-AC 8-channel DI, ꢁꢂ0Vac isolated, sinking
• NT-8ꢀꢀ4-DI-AC 8-channel DI, ꢁꢂ0Vac non-isolated, module powered
Digital Outputs
ꢁ5
ꢁ6
ꢁ7
ꢁ8
• NT-8ꢀꢀ5-DO-DC 8-channel DO, ꢁ-60Vdc non-isolated, module powered
• NT-8ꢀꢀ7-DO-DC 8-channel DO, ꢁ-60Vdc isolated, unpowered
• NT-8ꢀꢀ6-DO-AC8-channel DO, ꢁ0-ꢁ50Vac non-isolated, module powered
• NT-8ꢀꢀ8-DO-AC8-channel DO, ꢁ0-ꢁ50Vac isolated, unpowered
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢂ
Download from Www.Somanuals.com. All Manuals Search And Download.
8000 Series I/O
Product Catalog
Overview
Key Features
The NovaTech 8000 Series I/O is the newest remote I/O
family native to the D/3® Process Automation System
(PAS). It is the preferred I/O for new installations and
it can replace the older NovaTech 16000 series I/O
in existing PCM cabinets, using existing field wiring
connected to new termination panels with existing
connectors.
• Wide range of input and output types, in any mix
• Up to 64 I/O modules per node
• Up to 50 nodes per EthernetMPC card
• Wide operating temperature range, -40 to +70°C
• General-purpose and intrinsically-safe I/O within a
single node
• Redundant Local Area Networks (LAN) and power
supplies supported
With its -40 to +70° temperature range and G3 cor-
rosive coating, the NovaTech 8000 Series I/O is an I/O
system designed for field mounting. It connects to
conven-tional and smart field devices through multi-
channel I/O modules. The modules communicate, via
a fast internal bus, with redundant Ethernet Bus Inter-
face Modules (EBIMs) which provide dual-redundant
high speed Ethernet data connections to the D/3®.
• High channel density
• Zone 2 and Division 2 hazardous area mounting as
standard
• I/O module hot-swapping even in Zone 2 and Divi-
sion 2
• HART® pass-through supported
• Rugged construction, optimized for true field mount-
ing
• Integrated (per-channel) fusing and loop-disconnect
facility
• Bussed field power on carriers eliminates daisy-chain
wiring at field terminals
• Sophisticated mechanical keying system eliminates
risk to plant and personnel
Up to 64 I/O modules can be supported within a single
8000 Series node, and each module has between 4
and 16 channels. An EthernetMPC card can support
up to 50 nodes. With the availability of intrinsically
safe modules, 8000 Series I/O provides a solution for
both general purpose and hazardous area applications
- even within the same node.
8000 Series connects to both conventional (such as
4-20mA) and smart field devices. It allows the cost
benefits of fieldbus to be enjoyed with existing field
instruments—ideal for plant upgrades and expan-
sions. Pass-through of HART® information between
HART® instruments and the D/3® network is possible.
Designed for use with PCM 4100 or PCM 4200 PCI-
based PCMs, it requires an Ethernet Multi Protocol
Controller (EthernetMPC) card and D/3® version 12.2-2
or higher.
8000 Series nodes can be located within, and con-
nected into, a hazardous area where there is a risk
of explosion from flammable gases. The standard,
general purpose system is approved for operation in a
Zone 2 or Class I, Division 2 hazardous area, with field
devices in a similarly classified area. I/O modules with
intrinsically safe field circuits can be connected to
certified devices in Zone 0 and Class I, II, III, Division 1
hazardous areas.
Enclosures are also available for application where the
Series 8000 node must be located in a Zone 1 or Divi-
sion 1 area—consult NovaTech for availability.
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
4
Download from Www.Somanuals.com. All Manuals Search And Download.
8000 Series I/O
Product Catalog
Node Architecture
lation time by removing the need to make daisy chain
wiring connections at the field terminals of each I/O
module.
An 8000 Series node comprises single or redundant
Ethernet Bus Inter-face Modules, up to 64 I/O modules,
field terminals, and associated power supplies.
Node Operation
A schematic node architecture is shown below. In-
formation from the I/O modules is transferred to and
from the communication module (EBIM) via the Rail-
bus. The Railbus is a fast, serial data bus with parallel
module addressing and extends over the full length of
the node. The parallel address architecture means that
each I/O module position has a unique address which
eliminates the need to ‘train’ modules during installa-
tion.
A typical request for data from the field might happen
as follows:
The D/3® PAS requires the temperature from a par-
ticular thermocouple input at a particular node and
transmits a signal on the I/O LAN. There are several
Series 8000 nodes on the I/O LAN, but the EBIM at the
chosen node recognizes its own node address, and
acknowledges the request.
Power for the node is provided by integrated power
supply modules; these convert the locally available
power source into a regulated internal supply rail. This
rail energizes the EBIM and all Railbus communication
between the EBIM and I/O modules.
At each node, the input modules constantly monitor,
linearize and digitize their respective field signals,
and make them available to scanning on the node’s
internal bus (Railbus).
The EBIM continually scans the I/O modules via the
Railbus, and builds up a map of the values of the input
variables, ready for the PCM to read. These are con-
verted into the LAN protocol and placed on the LAN
by the EBIM, together with acknowledgement signals.
The D/3 then interprets the signal and reconstructs
the temperature reading.
For some I/O module types—such as those with
low-power and intrinsically safe field circuits—it also
provides power for the field wiring. Where additional
power is required for field devices (such as high cur-
rent AC circuits), power can be provided by means
of cabled connections from each module to external
relays. This Bussed Field Power facility reduces instal-
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
5
Download from Www.Somanuals.com. All Manuals Search And Download.
8000 Series I/O
Product Catalog
NovaTech 8000 Series I/O Components
Modules
Field Terminals
I/O modules transfer signals to and from field instru-
ments. Input modules receive signals from transmit-
ters and sensors and convert them into a digital form
for presentation to the EBIM. Output modules receive
commands from the EBIM and transfer them to actua-
tors. A wide range of modules is available, including
types for low-level instrumentation, AC circuits, and
intrinsically safe signals. I/O modules typically have 4,
8, or 16 field channels.
Field terminals provide the interface between the
I/O modules and the field wiring. They include fusing
and loop disconnect as options. A mechanical keying
system prevents an I/O module from being connected
to the wrong type of field terminal. Field terminals
mount onto the module carrier, one to each I/O
module. They are clamped firmly by the I/O module
to form an electrical and mechanical assembly of high
integrity. They may be replaced in service without
removing carriers or disturbing the operation of other
modules.
Carriers
Carriers allow the 8000 Series I/O to mount onto a flat
panel or T- or G-section DIN rail. They support and in-
terconnect the EBIM, power supplies, I/O modules and
field terminals, and carry the address, data and power
lines of the internal Railbus. They provide termination
points for the LAN and field wiring cable screens and
can also distribute bussed field power to the I/O mod-
ules. I/O module carriers support eight I/O modules.
Power Supplies
8000 Series I/O power supplies accept locally available
unregulated power and provide a regulated supply
for the EBIM and I/O modules. Supply redundancy is
supported. The system power supply at an 8000 Series
node converts the local DC supply to power the node,
and can also provide field power for I/O modules with
low-level field circuits. Where heavy-current or AC
mains circuits are handled by the I/O modules, the
8000 Series method for distributing field power avoids
complex wiring at the field terminal and minimizes the
backplane/carrier wiring.
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
6
Download from Www.Somanuals.com. All Manuals Search And Download.
8000 Series I/O
Product Catalog
Ethernet Bus Interface Module (EBIM)
NovaTech 8000 Series I/O uses the Ethernet Bus Inter-
face Module (EBIM) to provide a high speed Ethernet
data connection to the D/3®. The EBIMs communicate
using a propri-etary protocol over Ethernet at speeds
of 10/100MB to the D/3® PCMs.
NovaTech 8000 Series I/O Support
8000 Series I/O offers a variety of I/O boards and signal
conditioning termination panels suitable for virtually
every standard process sensor and actuator. Details
on signal conditioning termination panels, as well as
their associated I/O function boards, can be obtained
in individual specification sheets. The standard D/3®
configuration supports such I/O signals as:
• Analog Inputs: 4-20 mA, 10-50 mA, 0-10V (program-
mable ranges of 0-50mV, 0-100mV, 0-1V and 0-10V),
100 ohm platinum RTDs, thermocouples
• Pulse Train Inputs up to 50 Hz @ +10 to +32 VDC and
95 to 130 VAC
• Digital and Pulse Outputs:
• DC Output +5, +12, +24, and +5 to +60 VDC
• AC Output 12 to 140 VAC
• Pulse Output 2 msec. to 3.3 sec. @ +5, +12, +24, and
+5 to +60 VDC
• Pulse Output 10 msec. to 11 min. @ +5, +12, +24,
and +5 to +60 VDC
• Pulse Output 2 msec. to 3.3 sec. @ 12 to 140 VAC
• Pulse Output 10 msec. to 11 min. @ 12 to 140 VAC
• Analog Outputs: 4-20 mA, 10-50 mA, 0-10V
• Digital and Pulse Inputs:
• Contact Closures +5, +12, +24 and +10 to +32 VDC
• Contact Closures 95 to 130 VAC
• Pulse Train Inputs up to 100 KHz @ +5, +12, +24 VDC
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8KIO_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
7
Download from Www.Somanuals.com. All Manuals Search And Download.
8 Channel Analog Input
4–20 mA with HART®
. 8 single-ended 4-20 mA input channels
. Non-incendive field circuits
. HART pass-through
. HART variable and status reporting
. 2- or 4-wire transmitters
. open and short circuit detection
. 24 V dc bussed field power required
Module Specifications
Inputs
NovaTech 8000 Series I/O Family
Number of channels ...............................................8, single-ended
Nominal signal range (span) ..........................................4 to 20 mA
Full signal range.................................................................1 to 23 mA
Line fault detection
Configurable Parameters
Input filter time constant .................................user defined value
Input dead zone .................................................user defined value
Drive on failsafe............................. disabled /upscale /downscale
Channel status.......................................................... active /inactive
Short circuit current .....................................................> 23.5 mA
Open circuit current ......................................................< 0.5 mA
Output voltage (@ 20mA).............................................13.5 V (min.)
Output current ..............................................................32 mA (max.)
Accuracy (over temp range) ................................... 0.1% of span
Resolution ..................................................................................16 bits
Repeatability ................................................................0.05% of span
Isolation
HART variable and status reporting ................... enable /disable
Response Time
Signal change to availability on Railbus
4–20 mA mode .........................................................27 ms (max.)
HART mode......................................................0.75 s per channel
(any channel to Railbus) .................................................100 V ac
(between channels)................................................................none
Safety
FM non-incendive field wiring parameters (each channel)
Voc = 28.7 V; Isc = 33 mA; Ca = 0.17 µF; La = 11.0 mH
Power Supplies
Railbus (12V) current .....................100 mA (typ.), 150 mA (max.)
Bussed Field Power 2-wire Tx...................................300 mA (max.)
(@ 24 V dc 10%) 4-wire Tx.........................................60 mA (max.)
Mechanical
Module Key Code .............................................................................A1
Module width ............................................................................42 mm
Weight............................................................................................200 g
Field Terminals (2-WIRE TX)
Field Wiring
Recommended Compatible
Field Terminal
Field Terminal
General Purpose
NT-8602-FT-ST
Standard
NT-8604-FT-FU
Fused
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8601-FT-NI
Non-incendive
NT-8603-FT-FU
Non-incendive
Field Terminals (4-WIRE TX)
Field Wiring
Recommended Compatible
Field Terminal
NT-8615-FT-4W
NT-8615-FT-4W
Field Terminal
General Purpose
-
Class 1, Div 2
or Zone 2 hazard-
ous area
-
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8101_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
8
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Analog Input
4–20 mA
. 8 single-ended 4-20mA input channels
. Non-incentive field circuits
. 4-20mA
. 2- or 4-wire transmitters
. Open and short circuit detection
. 24Vdc bussed field power required
Module Specifications
Inputs
Number of channels ...............................................8, single-ended
Nominal signal range (span) ..........................................4 to 20 mA
Full signal range.................................................................1 to 23 mA
Out of range alarm
NovaTech 8000 Series I/O Family
Configurable Parameters
Input filter time constant .................................user defined value
Input dead zone .................................................user defined value
Drive on failsafe............................. disabled /upscale /downscale
Lower threshold.............................................................> 23.5 mA
Upper threshold .............................................................< 0.5 mA
Output voltage (@ 20 mA)............................................13.5 V (min.)
Output current ..............................................................32 mA (max.)
Accuracy (over temp range) ................................... 0.1% of span
Resolution ..................................................................................16 bits
Repeatability ................................................................0.05% of span
Isolation
Channel status.......................................................... active /inactive
Response Time
Signal change to availability on Railbus .................27 ms (max.)
Safety
FM non-incendive field wiring parameters (each channel)
..................Voc = 28.7 V; Isc = 33 mA; Ca = 0.17 µF; La = 11.0 mH
(any channel to Railbus) .................................................100 V ac
(between channels)................................................................none
Power Supplies
Railbus (12V) current .....................100 mA (typ.)/150 mA (max.)
Bussed Field Power ..................................2-wire Tx 300 mA (max.)
(@ 24 Vdc 10%) 4-wire Tx 60 mA (max.)
Mechanical
Module Key Code .............................................................................A1
Module width ............................................................................42 mm
Weight............................................................................................200 g
Field Terminals (2-wire TX)
Field Wiring
Recommended Compatible
Field Terminal
Field Terminal
General Purpose
NT-8602-FT-ST
Standard
NT-8604-FT-FU
Fused
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8601-FT-NI
Non-incendive
NT-8603-FT-FU
Non-incendive
Fused
Field Terminals (4-wire TX)
Field Wiring
Recommended Compatible
Field Terminal
NT-8615-FT-4W
NT-8615-FT-4W
Field Terminal
General Purpose
-
Class 1, Div 2
or Zone 2 hazard-
ous area
-
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8103_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
9
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Analog Input
1–5 V
. 8 single-ended input channels
. Non-incendive field circuits
. 1–5 V inputs open circuit and short circuit detection
. 24 V dc bussed field power required
Module Specifications
Inputs
Number of channels ...............................................8, single-ended
Nominal signal range (span) ................................................1 to 5 V
Full signal range ...........................................................0.19 to 5.64 V
Input impedance.........................................................................2 MΩ
Out of range alarm
NovaTech 8000 Series I/O Family
Mechanical
Module Key Code ............................................................A1
Module width .............................................................42 mm
Weight..........................................................................200 g
Lower threshold ................................................................< 0.19 V
Upper threshold ................................................................> 5.64 V
Accuracy (over temp range) ................................... 0.1% of span
Resolution ..................................................................................16 bits
Repeatability ................................................................0.05% of span
Isolation (any channel to Railbus) .....................................100 V ac
(between channels)................................................................none
Field Terminals
Field Wiring
Recommended Compatible
Field Terminal
Field Terminal
General Purpose
NT-8615-FT-4W
4-wire transmitter
-
Configurable Parameters
Input filter time constant .................................user defined value
Input dead zone .................................................user defined value
Drive on failsafe............................. disabled /upscale /downscale
Channel status.......................................................... active /inactive
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8615-FT-4W
4-wire transmitter
-
Response Time
Signal change to availability on Railbus .................27 ms (max.)
Safety
FM non-incendive field wiring parameters (each channel)
..................Voc = 28.7 V; Isc = 33 mA; Ca = 0.17 µF; La = 11.0 mH
Power Supplies
Railbus (12V) current .....................100 mA (typ.)/150 mA (max.)
Bussed Field Power ...................... 60 mA (max.) at 24 Vdc 10%
3AFE AREA
OR :ONE ꢀꢁ$IV ꢀ HAZARDOUS AREA
/THER
CHANNELS
-58
!ꢁ$
#HANNEL ꢂ OF ꢃ
M0
ꢂnꢄ6
$#
2AILBUS
ꢀꢁ 6DC
"USSED &IELD 0OWER
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8119_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢀ0
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Isolated Universal
Analog Input
4-20mA with Thermocouple, RTD, Voltage
• 8 isolated, universal, input channels
• Configurable on a channel by channel basis:
4-20mA, THC, RTD, resistance & voltage
• 250V ac rms channel to channel isolation
• Thermocouple types B, E, J, K, N, R, S, T, W3, W5, Russian
K, Russian L
• RTD types Pt100, jPt100, Pt200, Pt500, Ni120, Cu10
• Volt input types 120mV, 0-1V, 0-5V, 1-5V, 0-10V, 10V
• 2 or 3-wire RTDs
• 2 or 4-wire transmitters
NovaTech 8000 Series I/O Family
• Non-incendive field circuits
• 24 V dc bussed field power required
Resolution .......................................................................14 bits (typ.)
Optional open circuit bleed current .................... 1.2uA (nom.)
Open circuit detection time .....................................................1 sec
Module Specifications
Inputs
......................................................(with < 0.5 µF cable capacitance)
Number of configurable channels .................................8 isolated
RTD Input (2 or 3 Wire)
4-20mA Inputs
RTD types ....................Pt100, Pt200, Pt500, Cu10, Ni120; jPt100
Maximum wire resistance ...................................................40 ohms
Calibration accuracy 3-wire
Nominal signal range (span) ...........................................4 to 20mA
Full signal range (FSR).......................................................0 to 25mA
Output voltage (@ 20mA) ............................................13.5 V (min.)
Output current (linear operation) ............................25 mA (max.)
Short circuit current (max.) .................................75 mA for 100ms
(Output turns off after ~100ms at more than 25mA)
Calibration accuracy
10°C to 40°C ........................................................... 0.1% of span
–40°C to 70°C ........................................................ 0.2% of span
RTD excitation current .....................selected for ~0.2 mW at 0°C
Resolution .......................................................................14 bits (typ.)
Open circuit detection time .....................................................1 sec
......................................................(with < 0.5 µF cable capacitance)
10°C to 40°C ............................................................. 0.1% of FSR
–40°C to 70°C ........................................................... 0.3% of FSR
Resolution .......................................................................15 bits (typ.)
Repeatability ................................................................0.05% of span
Resistance Input (2 or 3 Wire)
Input resistance range (span) ...................................0 to 110, 280,
...............................................................................470 and 1000 ohms
Calibration accuracy 3-wire
Thermocouple Inputs
THC Types ....B, E, J, K, N, R, S, T, W3, W5, Russian K, Russian L
Calibration Accuracy
10°C to 40°C ........................................................... 0.2% of span
–40°C to 70°C ........................................................ 0.4% of span
Maximum wire resistance ...................................................40 ohms
Resistance excitation current ..selected for ~1.0 mW at max R
Resolution .......................................................................14 bits (typ.)
10°C to 40°C................................................. 0.1% of span (typ.)
–40°C to 70°C .............................................. 0.2% of span (typ.)
Cold junction compensation error †< 1°C (–40°C to + 70°C)
† C J compensation located in recommended field terminal
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢀꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Isolated Universal
Analog Input
4-20mA with Thermocouple, RTD, Voltage
Field Terminals
Voltage Input
Nominal signal range 1 (span) .............................. 120 mV, 0-1 V,
.........................................................................0-5V, 1-5V, 0-10V, 10V
Resolution .......................................................................14 bits (typ.)
Field Wiring
Recommended Compatible
Field Terminal
Field Terminal
All Purpose
THC
NT-8608-FT-RT
(no internal CJ)
8607-FT-TC (see
note) (internal CJ)
Configurable Parameters
Sensor type ................................................................user selectable
Input dead zone .................................................user defined value
Channel status ...........................................................active/inactive
Filter/sample rates ....................................................user selectable
NT-8606-FT-TC
(internal CJ)
8608-FT-RT (see
note) (no internal
CJ)
NOTE: For further advice on field terminals for this module
and for operations with more than one type of sensor, see
NovaTech 8000 I/O Hardware User’s Guide
General Specifications
Common mode rejection (using 50/60Hz filter) ...........................
.............................................................................> 120 dB @ 50/60 Hz
Series mode rejection (using 50/60Hz filter) .................................
................................................................................> 65 dB @ 50/60 Hz
Maximum input voltage (except current I/P) ...................... 25V
Common mode voltage between channels ...........250 V ac rms
Isolation
(channel to channel) ...............................................250 V ac rms
(any channel to Railbus) .........................................250 V ac rms
(any channel to Bussed Field Power) ..................250 V ac rms
(Railbus to Bussed Field Power) ............................150 V ac rms
Input filter frequency response .....................time constant 4 ms
Input impedance ..............................................................> 1 M ohm
Data Format ...............0 to 66535 corresponds to selected span
Open circuit detection ...........................................................< 1 sec
......................................................(with < 0.5 µF cable capacitance)
Safety
FM non-incendive field wiring parameters (each channel)
...........................Voc=20 V; Isc = 75mA; Ca= 0.61 µF; La= 11.3mH
Power Supplies
Railbus (12V) current ....................................................60 mA (typ.)
.........................................................................................125 mA (max.)
Bussed Field Power @ 24 V dc 10%
All configurations - except 4/20mA with excitation ..125 mA
(max.)
4/20mA with excitation ............................................300 mA (max.)
Mechanical
Module Key Code ...........................................................................A1*
Module width .............................................................................42mm
Weight ............................................................................................185g
* WARNING If this module is being used in an application that
requires 250V ac rms channel-to-channel isolation, it must be
replaced only with an A1 key code module that has equiva-
lent, or better, channel-to-channel isolation rating.
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢀꢁ
warranty. DS_8132_0607
Download from Www.Somanuals.com. All Manuals Search And Download.
4-channel Analog Input
Thermocouple and mV
. 4 thermocouple or mV* input channels
• Cold junction compensation
Module Specifications
Inputs
Number of channels ..........................................................................4
THCs types
.....................B,E,J,K,N,R,S, or T to EN 60584-2, IEC584-2, BS4937;
.............................................................................................W3 and W5
NovaTech 8000 Series I/O Family
Input Ranges
Configurabe Parameters
Input Type
Range
Sensor type ................................................................user selectable
Input dead zone (hysteresis)............................user defined value
Selectable input filtering ....off /2 reading avge./running avge.
Drive on open circuit fault......... disabled /upscale /downscale
Channel status...........................................................active/ inactive
mV
0 to 120 mV
Thermocouples: B
0 to 1820 °C
E
– 270 to + 1000 °C
– 210 to + 1200 °C
– 270 to + 1372 °C
– 50 to + 1768 °C
– 270 to + 400 °C
0 to + 2315 °C
J
K & N
R & S
T
Response Times
Signal change to availability on Railbus
...........................................................................................120 ms (min.)
..........................................................................................420 ms (max.)
O/C sensor detection.................................................................≤ 10 s
W3 & W5
Calibration Accuracy
Safety
mV input................................... 0.2% of span (– 40 to + 70 °C)
...................................................... 0.1% of span(+10 to + 40 °C)
THC input ...........................dependent on thermocouple type-
Cold junction compensation error†.......< 1°C (–40 to + 70 °C)
Resolution ..........................................................15 bits plus sign bit
Common mode rejection................................> 80 dB @ 50/60 Hz
Series mode rejection.......................................> 40 dB @ 50/60 Hz
Maximum input voltage ......................................................... 4.0 V
Common mode voltage between channels.......... 4.5 V (max.)
Isolation (any channel to Railbus) ............................250 V ac rms
Open circuit bleed current..................................... 0.5 µA (nom.)
FM non-incendive field wiring parameters (each channel)
...............Voc = 10.5 V; Isc = 3.6 mA; Ca = 14.9 µF; La = 1000 mH
Power Supplies
Railbus (12V) current...................................................150 mA (typ.)
.........................................................................................200 mA (max.)
Bussed Field Power .......................................................not required
Mechanical
Module Key Code .............................................................................C1
Module width ............................................................................42 mm
Weight............................................................................................200 g
Field Terminals
Field Wiring
Recommended Compatible
Field Terminal
Field Terminal
General Purpose
NT-8605-FT-TC
THC
-
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8605-FT-TC
THC
-
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8105_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢀꢂ
Download from Www.Somanuals.com. All Manuals Search And Download.
4-channel Analog Input
RTD and Ω
. 4 RTD or resistance* source inputs
. Function defined by configuration
. 2-, 3- or 4-wire RTD types accommodated
Module Specifications
Inputs
Number of channels ..........................................................................4
RTD input (2,3, or 4 wire)
....................................................Pt100 to BS1904/DIN43760/IEC 75
........................................................Ni120; jPt100 to JIS C1604: 1989
NovaTech 8000 Series I/O Family
Input Ranges
Configurabe Parameters
Sensor type....................................................................user selection
Input deadzone ..................................................user defined value
Selectable input filtering....off /2-reading avge./running avge.
Input Type
Resistance
Range
Consult NovaTech for availability
– 200 to + 850 °C
RTDs: Pt100
jPt100
Drive on open circuit fault................................. disabled /upscale
– 200 to + 510 °C
Channel status...........................................................active/ inactive
Offset (2-wire RTD mode).................................user defined value
Ni120
– 60 to + 320 °C
Response Times
Input resistance range (span)..........................................0 to 500 Ω
Accuracy (% of span)
Signal change to availability on Railbus
...........................................................................................180 ms (min.)
..........................................................................................840 ms (max.)
O/C sensor detection.................................................................≤ 10 s
Tamb
(RTD & Ω inputs)
25°C
0.05%
0.1%
0.2%
+10 to + 40°C
– 40 to + 70°C
Safety
FM non-incendive field wiring parameters (each channel)
...............Voc = 10.5 V; Isc = 3.6 mA; Ca = 14.9 µF; La = 1000 mH
RTD excitation current ..............................................200 μA (nom.)
Resolution ..........................................................15 bits plus sign bit
Common mode rejection................................> 80 dB @ 50/60 Hz
Series mode rejection.......................................> 40 dB @ 50/60 Hz
Isolation (any channel to Railbus) .............................250 V ac rms
Open circuit bleed current.........................................0.5 μA (nom.)
Power Supplies
Railbus (12V) current...................................................150 mA (typ.)
.........................................................................................200 mA (max.)
Bussed Field Power .......................................................not required
Mechanical
Module Key Code .............................................................................C1
Module width ............................................................................42 mm
Weight............................................................................................200 g
Field Terminals
Field Wiring
Recommended Compatible
Field Terminal
Field Terminal
General Purpose
NT-8606-FT-RT
RTD
-
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8606-FT-RT
RTD
-
*Consult NovaTech for availability.
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8106_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢀ4
Download from Www.Somanuals.com. All Manuals Search And Download.
8 Channel Analog Output
4–20 mA with HART®
. 8 single-ended 4-20 mA output channels
. Non-incendive field circuits
. HART pass-through
. HART variable and status reporting
. Valve positioners and remote indicators, etc.
. Open circuit detection on each channel
. 24 V dc bussed field power required
Module Specifications
Inputs
NovaTech 8000 Series I/O Family
Number of channels ...............................................8, single-ended
Nominal signal range (span) ..........................................4 to 20 mA
Full signal range.................................................................1 to 23 mA
Open loop detection threshold ...............................0.7 0.25 mA
Output compliance ..............................20 mA at 21.6 V dc supply
....................................................................................(into 700 Ω load)
Accuracy (over temp range) ................................. 0.25% of span
Resolution ..................................................................................12 bits
Isolation
Response Time
Signal change to availability on Railbus
4–20 mA mode .........................................................25 ms (max.)
HART mode......................................................0.75 s per channel
Safety
FM non-incendive field wiring parameters (each channel)
..................Voc = 28.7 V; Isc = 33 mA; Ca = 0.17 µF; La = 11.0 mH
(any channel to Railbus) .................................................100 V ac
(between channels)................................................................none
Power Supplies
Railbus (12V) current ..................................................100 mA (typ.)
.........................................................................................150 mA (max.)
Bussed Field Power .................... 300 mA (max.) at 24 Vdc 10%
Configurable Parameters
Initialization state..................................................predefined value
Drive on fail-safe ................................predefined value/last value
Channel status.......................................................... active /inactive
HART variable and status reporting.....................enable /disable
Mechanical
Module Key Code .............................................................................A4
Module width ............................................................................42 mm
Weight............................................................................................200 g
Field Terminals
Field Wiring
Recommended Compatible
Field Terminal
Field Terminal
General Purpose
NT-8602-FT-ST
Standard
NT-8604-FT-FU
Fused
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8601-FT-NI
Non-incendive
NT-8603-FT-FU
Non-incendive
3AFE AREA
OR :ONE ꢀꢁ$IV ꢀ HAZARDOUS AREA
2EGULATOR
/THER
CHANNELS
((#
-58
$ꢁ!
#HANNEL ꢂ OF ꢃ
M0
0
ꢁꢄꢀꢅM!
2AILBUS
)
ꢀꢁ 6DC
"USSED &IELD 0OWER
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8102_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢀ5
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Analog Output
4–20 mA
. 8 single-ended outputs
. 4–20 mA
. For I/P converters and remote indicators, etc
. Open circuit detection is provided on each channel
. 24 V dc bussed field power required
Module Specifications
Outputs
Number of channels ...............................................8, single-ended
Nominal signal range (span) ..........................................4 to 20 mA
Full signal output range ..................................................1 to 23 mA
Open loop detection threshold ...............................0.7 0.25 mA
Output compliance
NovaTech 8000 Series I/O Family
Mechanical
Module Key Code .............................................................................A4
Module width ............................................................................42 mm
Weight............................................................................................200 g
...................................20 mA at 21.6 V dc supply (into 700 Ω load)
Accuracy (over temp range) ................................. 0.25% of span
Output ripple............................................................< 0.02% of span
Resolution ..................................................................................12 bits
Isolation
Field Terminals
Field Wiring
Recommended Compatible
Field Terminal
any channel to Railbus ....................................................100 V ac
Field Terminal
General Purpose
NT-8602-FT-ST
Standard
NT-8604-FT-FU
Fused
Configurable Parameters
Initialization state..................................................predefined value
Drive on fail-safe ..............................predefined value / last value
Channel status..........................................................active / inactive
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8601-FT-NI
Non-incendive
NT-8603-FT-FU
Non-incendive
Fused
Response time
From Railbus command to output change ............25 ms (max.)
Safety
FM non-incendive field wiring parameters (each channel)
..................Voc = 28.7 V; Isc = 33 mA; Ca = 0.17 μF; La = 11.0 mH
Power Supplies
Railbus (12V) current ..................................................100 mA (typ.)
.........................................................................................150 mA (max.)
Bussed Field Power......................300 mA (max.) @ 24 V dc 10%
Quiescent current .....................................................................60 mA
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8104_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢀ6
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Discrete Input
24 V dc, isolated, sinking
. 8 discrete isolated inputs
. 24 V dc field voltage sources
. User definable input threshold
. Pulse counting option
Module Specifications
Inputs
Number of channels ...........................................................................8
OFF voltage...........................................................................< 3.2 V dc
ON voltage .............................................................................> 11 V dc
Wetting current ........................................6.3 mA (nom.) @ 24 V dc
Minimum pulse width detected ...............................................3 ms
Maximum switching frequency (no-filtering)....................200 Hz
Maximum voltage
NovaTech 8000 Series I/O Family
Mechanical
Module Key Code..............................................................................B2
Module width ............................................................................42 mm
Weight............................................................................................170 g
Input ......................................................................................30 V dc
Reverse input....................................................................– 25 V dc
Field Terminals
Configurable Parameters
Field Wiring
Recommended Compatible
Selectable input filter ...........................fast, slow or user defined
(User defined permits 0 to 512 ms values in 2ms steps)
Latch inputs................................................................enable /disable
Latch polarity......................................latch on high / latch on low
Pulse counting ..........................................................enable /disable
Field Terminal
Field Terminal
General Purpose
NT-8602-FT-ST
Standard †
NT-8604-FT-FU
Fused
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8601-FT-NA
Non-arcing †
NT-8611-FT-FU
Non-arcing,
Fused
Response Time
I/O response time
† External fusing of the Field Power supply is recommended
in order to protect the field wiring.
Field event to new data available on Railbus............3 ms (max.)
Safety
FM non-incendive field wiring parameters (each channel)
........................Vmax = 30 V; Imax = 100 mA; Ci = 0 μF; Li = 0 mH
Power Supplies
Railbus (12V) current......................................................35 mA (typ.)
...........................................................................................55 mA (max.)
Bussed Field Power .......................................................not required
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8109_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢀ7
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Discrete Input
24 V dc, non-isolated, module powered
. 8 discrete inputs for dry contact switches
. 24 V dc provided on input high side
. Returns commoned internally
. Pulse counting option
. 24 V dc bussed field power required
Module Specifications
Inputs
Number of channels ...........................................................................8
OFF current ..........................................................................< 0.69 mA
ON current............................................................................> 2.24 mA
Wetting current .................................................................5 mA (typ.)
Minimum pulse width detected ...............................................3 ms
Maximum switching frequency (no-filtering)....................200 Hz
Isolation (any channel to Railbus) .....................................250 V ac
NovaTech 8000 Series I/O Family
Mechanical
Module Key Code..............................................................................B1
Module width ............................................................................42 mm
Weight............................................................................................170 g
Field Terminals
Configurable Parameters
Field Wiring
Recommended Compatible
Selectable input filter ...........................fast, slow or user defined
(User defined permits 0 to 512 ms values in 2ms steps)
Latch inputs................................................................enable /disable
Latch polarity......................................latch on high / latch on low
Pulse counting ..........................................................enable /disable
Field Terminal
Field Terminal
General Purpose
NT-8602-FT-ST
Standard †
NT-8604-FT-FU
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8601-FT-NI
Non-incendive †
NT-8603-FT-FU
Non-incendive,
fused
Response Time
I/O response time
† External fusing of the field power supply is recommended
in order to protect the field wiring.
Field event to new data available on Railbus............3 ms (max.)
Safety
FM non-incendive field wiring parameters (each channel)
...................Voc = 30 V; Isc = 15.2 mA; Ca = 0.12 μF; La = 151 mH
Power Supplies
Railbus (12V) current......................................................35 mA (typ.)
...........................................................................................55 mA (max.)
Bussed Field Power ......................................40 mA, @ 18—36 V dc
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8110_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢀ8
Download from Www.Somanuals.com. All Manuals Search And Download.
16-channel Discrete Input
24 V dc, non-isolated, module-powered
. 16 input channels for dry contact switches
. 24 V dc provided on input high side
. Returns commoned internally
. Pulse counting option
. 24 V dc bussed field power required
Module Specifications
Inputs
Number of channels ........................................................................16
OFF current ............................................................................< 0.3 mA
ON current..............................................................................> 1.2 mA
Wetting current .............................................................2.8 mA (typ.)
Minimum pulse width detected ...............................................5 ms
Max input freq in pulse counting mode (no-debounce)100 Hz
Isolation (any channel to Railbus) .....................................250 V ac
NovaTech 8000 Series I/O Family
Mechanical
Module Key Code..............................................................................E1
Module width ...........................................................................42 mm
Weight............................................................................................210 g
Field Terminals
Configurable Parameters
Field Wiring
Recommended Compatible
Field Terminal
Selectable input filter ...........................fast, slow or user defined
(User defined permits 0 to 512 ms values in 2ms steps)
Latch inputs................................................................enable /disable
Latch polarity......................................latch on high / latch on low
Pulse counting ..........................................................enable /disable
Field Terminal
General Purpose
NT-8617-FT-NI
16 channel DI
-
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8617-FT-NI
16 channel DI
-
Response Time
I/O response time
Field event to new data available on Railbus............5 ms (max.)
Safety
FM non-incendive field wiring parameters (each channel)
..............Voc = 30 V; Isc = 3.5 mA; Ca = 0.12 μF; La = 1000 mH
Power Supplies
Railbus (12V) current......................................................90 mA (typ.)
.........................................................................................135 mA (max.)
Bussed Field Power.........................................60 mA, @ 18–30 V dc
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8121_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢀ9
Download from Www.Somanuals.com. All Manuals Search And Download.
16-channel Discrete Input
24 V dc, isolated, sinking
. 16 input channels
. 24 V dc field voltage sources
. Individually isolated channels
. User definable input threshold
. Pulse counting option
Module Specifications
Inputs
Number of channels ........................................................................16
OFF voltage...........................................................................< 3.4 V dc
ON voltage .............................................................................> 11 V dc
Wetting current ........................................2.8 mA (nom.) @ 24 V dc
Minimum pulse width detected ...............................................5 ms
Max input freq in pulse counting mode (no-debounce)100 Hz
Maximum voltage
NovaTech 8000 Series I/O Family
Power Supplies
Railbus (12V) current......................................................90 mA (typ.)
.........................................................................................135 mA (max.)
Bussed Field Power .......................................................not required
Mechanical
Input ......................................................................................30 V dc
Reverse input ................................................................. – 25 V dc
Isolation (Any Channel to railbus) .....................................250 V ac
Isolation (channel to channel) ......................................150 V peak
Module Key Code .............................................................................E2
Module width ............................................................................42 mm
Weight............................................................................................210 g
Configurable Parameters
Selectable input filter ...........................fast, slow or user defined
(User defined permits 0 to 512 ms values in 2ms steps)
Pulse counting ..........................................................enable /disable
Field Terminals
Field Wiring
Recommended Compatible
Field Terminal
NT-8617-FT-NI †
16 channel DI
Field Terminal
Response Time
General Purpose
-
I/O response time ............................................................5 ms (max.)
(Field event to new data available on Railbus)
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8617-FT-NI †
16 channel DI
-
Safety
FM non-incendive field wiring parameters (each channel)
......................Vmax = 30 V; Imax = 100 mA; Ci = 0 µF; Li = 0 mH
† External fusing of the Field Power supply is recommended
in order to protect the field wiring.
3AFE AREA
OR :ONE ꢀꢁ$IV ꢀ HAZARDOUS AREA
MP
#
HA
NNE
L ꢀ
O
F ꢀ
ꢁ
24V
2AILBUS
DC
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8122_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢁ0
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Discrete Input
115 V ac, isolated, sinking
. 8 discrete inputs
. 115 V ac field voltage sources
. User definable input threshold
. Pulse counting option
Module Specifications
Inputs
Number of channels ...........................................................................8
OFF voltage............................................................................< 34 V ac
ON voltage .............................................................................> 84 V ac
Wetting current .........................................2 mA (nom.) @ 115 V ac
Max. input voltage ................................................................130 V ac
Frequency ............................................................................50 / 60 Hz
NovaTech 8000 Series I/O Family
Field Terminals
Field Wiring
Recommended Compatible
Field Terminal
NT-8602-FT-ST
Standard †
Field Terminal
NT-8604-FT-FU
Fused
Configurable Parameters
General Purpose
Selectable input filter ...........................fast, slow or user defined
(User defined permits 0 to 512 ms values in 2ms steps)
Latch inputs................................................................enable /disable
Latch polarity......................................latch on high / latch on low
Pulse counting ..........................................................enable /disable
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8610-FT-NA
Non-arching †
NT-8611-FT-FU
Non-arching,
fused
† External fusing of the Field Power supply is recommended
in order to protect the field wiring.
Response Time
I/O response time
Field event to new data available on Railbus....33 ms (max.)
Power Supplies
Railbus (12V) current......................................................40 mA (typ.)
...........................................................................................60 mA (max.)
Bussed Field Power .......................................................not required
Mechanical
Module Key Code..............................................................................E4
Module width ............................................................................42 mm
Weight............................................................................................170 g
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8111_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢁꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Discrete Input
115 V ac, non-isolated, module powered
. 8 discrete inputs for dry contact switches
. 115 V ac provided on input high side
. Returns commoned internally
. Pulse counting option
. 115 V ac Bussed Field Power required
Module Specifications
Inputs
Number of channels ...........................................................................8
OFF current ..........................................................................< 0.56 mA
ON current..............................................................................> 1.4 mA
Wetting current .........................................2 mA (nom.) @ 115 V ac
NovaTech 8000 Series I/O Family
Field Terminals
Field Wiring
Recommended Compatible
Configurable Parameters
Field Terminal
Field Terminal
Selectable input filter ...........................fast, slow or user defined
(User defined permits 0 to 512 ms values in 2ms steps)
Latch inputs................................................................enable /disable
Latch polarity......................................latch on high / latch on low
Pulse counting ..........................................................enable /disable
General Purpose
NT-8604-FT-FU
Fused
NT-8602-FT-ST
Standard †
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8611-FT-FU
Non-arcing,
Fused
NT-8610-FT-NA
Non-arcing †
† Alternative fusing in the field wiring is recommended if it is
not provided in the field terminal.
Response Time
I/O response time
Field event to new data available on Railbus....33 ms (max.)
Power Supplies
Railbus (12V) current......................................................40 mA (typ.)
...........................................................................................60 mA (max.)
Bussed Field Power ...................................................115 V ac 10%
Frequency ............................................................................50 / 60 Hz
Mechanical
Module Key Code..............................................................................E1
Module width ............................................................................42 mm
Weight............................................................................................170 g
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8112_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢁꢁ
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Discrete Input
230 V ac, isolated, sinking
. 8 discrete isolated inputs
. 230 V ac field voltage sources
. User definable input threshold
. Pulse counting option
Module Specifications
Inputs
Number of channels ...........................................................................8
OFF voltage............................................................................< 68 V ac
ON voltage ...........................................................................> 168 V ac
Wetting current .........................................1 mA (nom.) @ 230 V ac
Max. input voltage ................................................................265 V ac
Frequency ............................................................................50 / 60 Hz
NovaTech 8000 Series I/O Family
Field Terminals
Field Wiring
Recommended Compatible
Configurable Parameters
Field Terminal
Field Terminal
General Purpose
Selectable input filter ...........................fast, slow or user defined
(User defined permits 0 to 512 ms values in 2ms steps)
Latch inputs................................................................enable /disable
Latch polarity......................................latch on high / latch on low
Pulse counting ..........................................................enable /disable
NT-8602-FT-ST
Standard †
NT-8604-FT-FU
Fused
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8610-FT-NI
Non-arcing †
NT-8611-FT-FU
Non-arcing,
fused
† External fusing of the Field Power supply is recommended
in order to protect the field wiring.
Response Time
I/O response time
Field event to new data available on Railbus....33 ms (max.)
Power Supplies
Railbus (12V) current......................................................40 mA (typ.)
...........................................................................................60 mA (max.)
Bussed Field Power .......................................................not required
Mechanical
Module Key Code..............................................................................E5
Module width ............................................................................42 mm
Weight............................................................................................170 g
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8113_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢁꢂ
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Discrete Input
230 V ac, non-isolated, module powered
. 8 discrete inputs for dry contact switches
. 230 V ac provided on input high side
. Returns commoned internally
. Pulse counting option
. 230 V ac Bussed Field Power required
Module Specifications (See also System Specification)
Inputs
Number of channels ...........................................................................8
OFF current ..........................................................................< 0.28 mA
ON current............................................................................> 0.71 mA
Wetting current .........................................1 mA (nom.) @ 230 V ac
NovaTech 8000 Series I/O Family
Field Terminals
Field Wiring
Recommended Compatible
Configurable Parameters
Field Terminal
Field Terminal
Selectable input filter ...........................fast, slow or user defined
(User defined permits 0 to 512 ms values in 2ms steps)
Latch inputs................................................................enable /disable
Latch polarity......................................latch on high / latch on low
Pulse counting ..........................................................enable /disable
General Purpose
NT-8604-FT-FU
Fused
NT-8602-FT-ST
Standard †
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8611-FT-FU
Non-arcing,
Fused
NT-8610-FT-NA
Non-arcing †
† Alternative fusing in the field wiring is recommended if it is
not provided in the field terminal.
Response Time
I/O response time
Field event to new data available on Railbus....33 ms (max.)
Power Supplies
Railbus (12V) current......................................................40 mA (typ.)
...........................................................................................60 mA (max.)
Bussed Field Power ..................................................207 to 265 V ac
Frequency ............................................................................50 / 60 Hz
Mechanical
Module Key Code..............................................................................E2
Module width ............................................................................42 mm
Weight............................................................................................170 g
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8114_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢁ4
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Discrete Output
2–60 V dc, non-isolated, module powered
. 8 powered outputs
. Controls solenoids and relays
. Common load supply of up to 60 V dc
. Discrete or pulsed outputs
. 1A per channel switched current
. 2–60 V dc bussed field power required
Module Specifications
Outputs
NovaTech 8000 Series I/O Family
Number of channels ...........................................................................8
Output voltage range.........................................................2–60 V dc
ON voltage drop.............................................................0.25 V (max.)
OFF leakage current ...................................................1.0 mA (max.)
Switched current per channel ††
Mechanical
Module Key Code..............................................................................B6
Module width ............................................................................42 mm
Weight............................................................................................200 g
Continuous *................................................................................1 A
For < 100 ms.................................................................................4 A
For < 20 ms...................................................................................6 A
Field Terminals
Field Wiring
Recommended Compatible
Field Terminal
Field Terminal
Configurable Parameters
General Purpose
NT-8604-FT-FU
Fused
NT-8602-FT-ST
Standard †
Output initialization state....................................predefined
value
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8611-FT-FU
Non-arcing,
Fused
NT-8610-FT-NA
Non-arcing †
Fail-safe.................................................predefined value/last value
Output .....................discrete, momentary or continuous pulse‡
Pulse width.....................................................................2 ms to 130 s
Response Time
† Alternative fusing in the field wiring is recommended if it is
not provided in the field terminal.
†† The total instantaneous switched current should not
exceed the following:
Response time
From Railbus command to output change ..........1 ms (max.)
Power Supplies
10 A for < 100 ms
Railbus (12V) current......................................................45 mA (typ.)
...........................................................................................70 mA (max.)
Bussed Field Power .........................................................2 to 60 V dc
18 A for < 20 ms
*Limited to 6 A per module
‡Consult NovaTech for availability
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8115_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢁ5
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Discrete Output
2–60 V dc, isolated, unpowered
. 8 fully isolated semiconductor switched outputs
. Controls solenoids and relays
. For load supplies of up to 60 V dc
. Discrete or pulsed outputs
. 1A per channel switched
Module Specifications
Outputs
Number of channels ...........................................................................8
Output voltage range.........................................................2–60 V dc
ON voltage drop.............................................................0.25 V (max.)
OFF leakage current ...................................................1.0 mA (max.)
Switched current per channel
NovaTech 8000 Series I/O Family
Field Terminals
Field Wiring
Recommended Compatible
Field Terminal
NT-8604-FT-FU
Fused
Continuous...................................................................................1 A
For < 100ms .................................................................................4 A
For < 20ms ...................................................................................6 A
Field Terminal
NT-8602-FT-ST
Standard
General Purpose
Configurable Parameters
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8611-FT-FU
Non-arcing,
Fused
NT-8610-FT-NA
Non-arcing
Output initialization state...................................predefined value
Fail-safe.................................................predefined value/last value
Output .....................discrete, momentary or continuous pulse‡
Pulse width.....................................................................2 ms to 130 s
Note: External fusing to protect field wiring is recommended.
‡Consult NovaTech for availability.
Response Time
Response time
From Railbus command to output change ..........3 ms (max.)
Power Supplies
Railbus (12V) current......................................................45 mA (typ.)
...........................................................................................70 mA (max.)
Bussed Field Power .......................................................not required
Mechanical
Module Key Code..............................................................................B5
Module width ............................................................................42 mm
Weight............................................................................................200 g
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8117_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢁ6
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Discrete Output
20–265 V ac, non-isolated, module powered
. 8 powered outputs
. Controls solenoids and relays
. Common load supply of up to 265 V ac
. Discrete or pulsed outputs
. 1A per channel maximum
. 20–265 V ac bussed field power required
Module Specifications
Outputs
NovaTech 8000 Series I/O Family
Number of channels ...........................................................................8
Output voltage range.....................................................20–265 V ac
Frequency ............................................................................50 / 60 Hz
ON voltage drop........................................................................< 1.2 V
OFF leakage current .................................................................< 4mA
Switched current per channel ††
Mechanical
Module Key Code .............................................................................F1
Module width ............................................................................42 mm
Weight............................................................................................220 g
Field Terminals
Continuous.................................................................................1 A*
For < 100 ms.................................................................................5 A
For < 20 ms.................................................................................20 A
Minimum load current, per channel
Field Wiring
Recommended Compatible
Field Terminal
Field Terminal
@ 115 V ac...............................................................................11 mA
@ 230 V ac.................................................................................5 mA
General Purpose
NT-8604-FT-FU
Fused
NT-8602-FT-ST
Standard †
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8611-FT-FU
Non-arcing,
Fused
NT-8610-FT-NA
Non-arcing †
Configurable Parameters
Output initialization state...................................predefined value
Fail-safe.................................................predefined value/last value
Output .....................discrete, momentary or continuous pulse‡
Pulse width.....................................................................2 ms to 130 s
† Alternative fusing in the field wiring is recommended if it is
not provided in the field terminal.
Response Time
†† Stated figures are for operation with unfused field termi-
nal. When operating with 2 A fused field terminal part no.
NT-8604-FT-FU, maximum switched current is 5 A inrush for
<10 ms pulse width at 0.1% duty cycle and <108 operations
*Limited to 3 A per module.
Response time (max.) ..2 ms + 1/2 cycle of mains frequency
(From Railbus command to output change)
Power Supplies
Railbus (12V) current......................................................75 mA (typ.)
..........................................................................................125mA (max.)
Bussed Field Power (voltage)....................................20 to 265 V ac
‡Consult NovaTech for availability
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8116_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢁ7
Download from Www.Somanuals.com. All Manuals Search And Download.
8-channel Discrete Output
20–265 V ac, isolated, unpowered
. 8 fully isolated semiconductor switched outputs
. Controls solenoids and relays
. For load supplies of up to 250 V ac
. Discrete or pulsed outputs
. 1A per channel switched
Module Specifications
Outputs
Number of channels ...........................................................................8
Output voltage range.....................................................20–265 V ac
Frequency ............................................................................50 / 60 Hz
ON voltage drop........................................................................< 1.2 V
OFF leakage current ...............................................................< 4 mA
Switched current per channel †
NovaTech 8000 Series I/O Family
Mechanical
Module Key Code .............................................................................F4
Module width ...........................................................................42 mm
Weight............................................................................................220 g
Continuous.................................................................................1 A*
For < 100ms .................................................................................5 A
For < 20ms .................................................................................20 A
Minimum load current, per channel
Field Terminals
Field Wiring
Recommended Compatible
Field Terminal
@ 115 V ac...............................................................................11 mA
@ 230 V ac.................................................................................5 mA
Field Terminal
NT-8602-FT-ST
Standard
General Purpose
NT-8604-FT-FU
Fused
Configurable Parameters
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8611-FT-FU
Non-arcing,
Fused
NT-8610-FT-NA
Non-arcing
Output initialization state...................................predefined value
Fail-safe.................................................predefined value/last value
Output .....................discrete, momentary or continuous pulse‡
Pulse width.....................................................................2 ms to 130 s
† Stated figures are for operation with unfused field terminal.
When operating with 2 A fused field terminal part no. NT-
8604-FT-FU, maximum switched current is 5 A inrush for <10
ms pulse width at 0.1% duty cycle and <108 operations.
* Limited to 3 A per module.
Response Time
Response time (max.) ..2 ms + 11⁄42 cycle of mains frequency
(From Railbus command to output change)
Power Supplies
‡Consult NovaTech for availability
Railbus (12V) current......................................................75 mA (typ.)
.........................................................................................125 mA (max.)
Bussed Field Power .......................................................not required
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks
are properties of their respective owners. NovaTech is a registered
trademark of NovaTech, LLC. The information in this literature is
subject to change without notice and is not to be construed as a
warranty. DS_8118_0607
Contact:
NovaTech Process Solutions, LLC
11500 Cronridge Dr., Suite 110
Owings Mills, MD 21117
T: 410.753.8300
Toll Free: 800.253.3842
ꢁ8
Download from Www.Somanuals.com. All Manuals Search And Download.
|