Nortec Industries Humidifier MES Series User Manual

MES  
Series  
Electrode  
Steam  
Humidifiers  
Designed for internal use in  
specialty air handling equipment  
Download from Www.Somanuals.com. All Manuals Search And Download.  
operating advantages  
Precise control  
MES installations handle the most demanding  
challenges. Each unit is controlled by its  
own integral electronics. Just preset your  
humidification requirements.  
Economy  
Installation Flexibility  
Unlike older systems that are often difficult and  
costly to maintain, the MES electrode steam  
system produces pure, uncontaminated moisture  
to protect sensitive equipment and the people  
using it. There are no heating elements to get  
coated with mineral deposits and sludge.  
MES Series humidifiers offer unprecedented  
installation flexibility. They can be configured for  
both small and large systems and are ideal in  
computer room and specialty air handling systems.  
Steam distribution is easily accomplished through  
the air handler duct system.  
Any water-borne impurities are removed at the  
electrodes and deposited in a replaceable cylinder  
where they are periodically flushed out through  
the automatic cylinder drain. Solid mineral  
scale sinks to the bottom of the cylinder which,  
when filled with residue, is easily discarded and  
replaced.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
technology  
Electrode Steam  
System Features  
Disposable steam cylinder  
Clean and hygenic steam  
Energy efficient  
Compact size  
Adjustable output  
Two year limited warranty  
Adjusts to varying water conditions  
Easily installed in air handlers  
Wide range of models and capacities  
Cylinder replacement is quick and easy  
Patented auto-adaptive control  
Automatic drain water tempering  
C_UL-US Recognized  
On/off or modulation control  
Primary voltage connections on models H and I  
Optional RS485 2-wire Modbus RTU Bus Building Automation  
System Interface  
Operation run time in hours with remote reset  
Steam output displayed in lbs/hr  
Enable/Disable humidifier  
MES  
End of cylinder life indication  
Humidifier alarm/System faults status  
Electrode current displayed in amps  
Capacity output adjustment  
Series  
Electrode  
Steam  
Operational hour counter  
Cylinder drain flushing sequence  
Humidifiers  
Modbus Communication  
Modbus interface board will provide monitoring  
and control of all critical points via Building  
Automation System. It is easily mounted to the  
main board using a ribbon cable connection.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
system configurations  
NORTEC offers a choice of product configurations in the MES Series.  
Units offer capacities from 5 to ꢁ0 pounds of moisture per hour from 1.7 to 10.ꢀ kW.  
See technical data for compatibility details.  
A style  
B style  
C style  
D style  
E style  
F style  
G style  
H style  
I style  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
technical data  
Electrode Steam  
SPECIFICaTION  
05  
10  
15  
15  
20  
20  
25  
30  
Capacity: lbs/hr*  
2-5  
2-10  
3-15  
3-15  
4-20  
4-20  
5-25  
6-30  
Capacity: kg/hr*  
Input kW max  
0.9-2.3  
1.79  
0.9-4.5  
3.4  
1.4-6.8  
5.1  
1.4-6.8  
5.1  
1.8-9.1  
6.8  
1.8-9.1  
6.8  
2.3-11.34  
8.5  
2.7-13.6  
10.2  
208/230/277 208/230/277 208/230/277 208/230 208/230/277 208/230  
208/230  
380/460/575  
208/230  
380/460/575  
Voltage  
380/460/575  
380/460/575  
380/460/575  
380/460/575  
380/460/575  
380/460/575  
Phase  
1
1
1
3
1
3
3
3
Cylinder  
100  
200  
300  
300  
300  
300  
400  
400  
ꢀ5-ꢁ0  
15-ꢀ0  
5-10  
ꢀ-5  
Physical Dimensions  
SPECIFICaTION  
05  
10  
15  
20  
25  
30  
6.6  
(16.7 cm)  
6.6  
(16.7 cm)  
8.4  
(21.3 cm)  
8.4  
(21.3 cm)  
10.5  
(26.7 cm)  
10.5  
(26.7 cm)  
Depth  
8.6  
(21.9 cm)  
8.6  
(21.9 cm)  
10.5  
(26.7 cm)  
10.5  
(26.7 cm)  
10.5  
(26.7 cm)  
10.5  
(26.7 cm)  
Width (remote electrical)  
Width (attached electrical)  
Height  
10.7  
(21.7 cm)  
10.7  
(21.7 cm)  
12.6  
(32.2 cm)  
12.6  
(32.2 cm)  
12.6  
(32.2 cm)  
12.6  
(32.2 cm)  
13.5  
(34.4 cm)*  
17.3  
(43.9 cm)  
19.4  
(49.3 cm)  
19.4  
(49.3 cm)  
21.3.4  
(54.0 cm)  
21.3.4  
(54.0 cm)  
NOTES: Dimensions reflect fully enclosed cabinets. Precise dimensions of other cabinet configurations may vary slightly.  
* For 5 lb primary voltage connection units, the height will be the same as a 10 lb unit.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
U.S.a.  
AxAir Nortec Inc.  
8ꢀꢃ Proctor Avenue  
Ogdensburg, NY 1ꢁꢃꢃ9  
CaNaDa  
AxAir Nortec Ltd.  
ꢀ7ꢂ0 Fenton Road  
Ottawa, Ontario K1T ꢁT7  
TEl: 1.8ꢃꢃ.NORTEC1  
FAx: ꢃ1ꢁ.8ꢀꢀ.79ꢃꢂ  
Certificate No. 002419  
electric steam — atomizing nozzles — high pressure nozzles — steam injection — steam exchange — gas steam  
Form 07-10ꢃ  
Printed in Canada  
Printed on Recycled Paper  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Clothes Dryer T4322 User Manual
Multi Tech Systems Network Card 40 01459 D0 001 User Manual
Napco Security Technologies Home Security System GEM X255 User Manual
NewAir Air Conditioner ACP 1300E User Manual
Norcent Technologies Flat Panel Television LT 3790 User Manual
Optimus Portable CD Player CD 3680 42 5075 User Manual
Panasonic CD Player CQ C7300N User Manual
Panasonic Computer Drive CF VFS721 User Manual
Panasonic Electric Shaver ER430K User Manual
Panasonic Network Card MAZTxxxH Series User Manual