MES
™
Series
Electrode
Steam
Humidifiers
Designed for internal use in
specialty air handling equipment
Download from Www.Somanuals.com. All Manuals Search And Download.
operating advantages
Precise control
MES installations handle the most demanding
challenges. Each unit is controlled by its
own integral electronics. Just preset your
humidification requirements.
Economy
Installation Flexibility
Unlike older systems that are often difficult and
costly to maintain, the MES electrode steam
system produces pure, uncontaminated moisture
to protect sensitive equipment and the people
using it. There are no heating elements to get
coated with mineral deposits and sludge.
MES Series humidifiers offer unprecedented
installation flexibility. They can be configured for
both small and large systems and are ideal in
computer room and specialty air handling systems.
Steam distribution is easily accomplished through
the air handler duct system.
Any water-borne impurities are removed at the
electrodes and deposited in a replaceable cylinder
where they are periodically flushed out through
the automatic cylinder drain. Solid mineral
scale sinks to the bottom of the cylinder which,
when filled with residue, is easily discarded and
replaced.
ꢁ
Download from Www.Somanuals.com. All Manuals Search And Download.
technology
Electrode Steam
System Features
Disposable steam cylinder
▶
▶
▶
▶
▶
▶
▶
Clean and hygenic steam
Energy efficient
Compact size
Adjustable output
Two year limited warranty
Adjusts to varying water conditions
Easily installed in air handlers
Wide range of models and capacities
Cylinder replacement is quick and easy
Patented auto-adaptive control
Automatic drain water tempering
C_UL-US Recognized
On/off or modulation control
Primary voltage connections on models H and I
Optional RS485 2-wire Modbus RTU Bus Building Automation
System Interface
Operation run time in hours with remote reset
Steam output displayed in lbs/hr
Enable/Disable humidifier
MES
End of cylinder life indication
Humidifier alarm/System faults status
Electrode current displayed in amps
Capacity output adjustment
™
Series
Electrode
Steam
Operational hour counter
Cylinder drain flushing sequence
Humidifiers
Modbus Communication
Modbus interface board will provide monitoring
and control of all critical points via Building
Automation System. It is easily mounted to the
main board using a ribbon cable connection.
ꢂ
Download from Www.Somanuals.com. All Manuals Search And Download.
system configurations
NORTEC offers a choice of product configurations in the MES Series.
Units offer capacities from 5 to ꢁ0 pounds of moisture per hour from 1.7 to 10.ꢀ kW.
See technical data for compatibility details.
A style
B style
C style
D style
E style
F style
G style
H style
I style
5
Download from Www.Somanuals.com. All Manuals Search And Download.
technical data
Electrode Steam
SPECIFICaTION
05
10
15
15
20
20
25
30
Capacity: lbs/hr*
2-5
2-10
3-15
3-15
4-20
4-20
5-25
6-30
Capacity: kg/hr*
Input kW max
0.9-2.3
1.79
0.9-4.5
3.4
1.4-6.8
5.1
1.4-6.8
5.1
1.8-9.1
6.8
1.8-9.1
6.8
2.3-11.34
8.5
2.7-13.6
10.2
208/230/277 208/230/277 208/230/277 208/230 208/230/277 208/230
208/230
380/460/575
208/230
380/460/575
Voltage
380/460/575
380/460/575
380/460/575
380/460/575
380/460/575
380/460/575
Phase
1
1
1
3
1
3
3
3
Cylinder
100
200
300
300
300
300
400
400
ꢀ5-ꢁ0
15-ꢀ0
5-10
ꢀ-5
Physical Dimensions
SPECIFICaTION
05
10
15
20
25
30
6.6
(16.7 cm)
6.6
(16.7 cm)
8.4
(21.3 cm)
8.4
(21.3 cm)
10.5
(26.7 cm)
10.5
(26.7 cm)
Depth
8.6
(21.9 cm)
8.6
(21.9 cm)
10.5
(26.7 cm)
10.5
(26.7 cm)
10.5
(26.7 cm)
10.5
(26.7 cm)
Width (remote electrical)
Width (attached electrical)
Height
10.7
(21.7 cm)
10.7
(21.7 cm)
12.6
(32.2 cm)
12.6
(32.2 cm)
12.6
(32.2 cm)
12.6
(32.2 cm)
13.5
(34.4 cm)*
17.3
(43.9 cm)
19.4
(49.3 cm)
19.4
(49.3 cm)
21.3.4
(54.0 cm)
21.3.4
(54.0 cm)
NOTES: Dimensions reflect fully enclosed cabinets. Precise dimensions of other cabinet configurations may vary slightly.
* For 5 lb primary voltage connection units, the height will be the same as a 10 lb unit.
ꢃ
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
U.S.a.
AxAir Nortec Inc.
8ꢀꢃ Proctor Avenue
Ogdensburg, NY 1ꢁꢃꢃ9
CaNaDa
AxAir Nortec Ltd.
ꢀ7ꢂ0 Fenton Road
Ottawa, Ontario K1T ꢁT7
TEl: 1.8ꢃꢃ.NORTEC1
FAx: ꢃ1ꢁ.8ꢀꢀ.79ꢃꢂ
WEBSITE: www.humidity.com
Certificate No. 002419
electric steam — atomizing nozzles — high pressure nozzles — steam injection — steam exchange — gas steam
Form 07-10ꢃ
Printed in Canada
Printed on Recycled Paper
Download from Www.Somanuals.com. All Manuals Search And Download.
|