H O M E T H E AT E R A U T O M AT I O N A N D C O N T R O L S Y S T E M
���
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
The Niles iC2 Home Theater Automation and Control System addresses an essential need of
today’s consumers—the ability to easily control and manage the assortment of entertainment
sources found in the home theater environment.
Home entertainment systems should be fun, not frustrating, and Niles has always recognized the
need for simple-to-use, cost-effective solutions. We also recognize that features and technologies
change over time, and more so than ever, these changing technologies require advanced
automation, as well as an easy-to-use remote control.
The iC2 System consists of two main components: the iC2 Remote and the Home Theater Main
System Unit (HT-MSU). The iC2 Remote incorporates large buttons and a logical layout of function
keys that reflect today’s popular and menu-driven sources so anyone in the family can operate
complex systems. And, unlike traditional remote controls, the iC2 Remote does not require users
to point the remote at the products to be controlled.
The HT-MSU, or the “brains” of the iC2 System, stores the complete system profile (i.e., television,
surround receiver, cable boxes, satellite receiver, DVD, etc.). In addition, the HT-MSU can automate
functions like lighting control, TV lifts, draperies, projection screens, and more.
The Niles iC2 System gives end users one-touch control of their home theater system and reflects
the high quality fit and finish that meets the standards
of today’s consumers.
Niles is one of the industry’s most respected manufacturers of custom installation audio/video
components and accessories. To see the complete line of Niles products, visit us on the Internet at:
1
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
Download from Www.Somanuals.com. All Manuals Search And Download.
FEATURES AND BENEFITS
SIMPLE CONTROL OF COMPLEX SYSTEMS
The iC2 Home Theater Automation and Control System simplifies entertainment by allowing one-
touch control of home theater components. Ordinary home theater system controllers require users
to turn on (and off) multiple components, resulting in a confusing situation of hunting down the
fugitive component that is “off,” when it really should be “on.”
The iC2 System eliminates the confusion—a single touch of any of the eight installer-labeled
“activity” keys will initiate an intelligent sequence of commands, so whether you’re playing a DVD
or watching a program recorded on your DVR, the iC2 System provides quick and easy access to
your entertainment.
A COMPLETE SYSTEM
The iC2 System consists of an ergonomically designed Radio Frequency (RF) tabletop-styled
remote control and an “intelligent” Home Theater Main System Unit (HT-MSU). Powerful
combinations of hardware and software functions within the Main System Unit manage and
automate control of every aspect of a home theater.
BIG BUTTON REMOTE WITH CONVENIENT FEATURES
The iC2 Remote is refreshingly practical with large, customizable source keys and backlighting
that can be used in low-light environments and without looking at the buttons. Its rechargeable
battery has a long “off-charger” life, and users don’t have to change batteries. The iC2 Remote is a
big button remote that can be programmed to control today’s most popular entertainment sources.
Large channel up and down keys offer quick channel surfing and a system off key provides one-
touch turn off of the entire home theater system.
INTELLIGENT MAIN SYSTEM UNIT
The HT-MSU has both video and 12 Volt sync inputs to manage the power “state” of all your home
theater system components. With eight power sensing (synchronization) ports, eight IR (infrared)
ports, and eight RS232 (serial) ports and an expansion port, the HT-MSU can control up to 29
devices. The HT-MSU also includes “dry contact closure” relays and 12V trigger outputs that can
be used to control things like projector lifts, screens, drapes or lighting; and an “Ethernet” port is
included for system expansion, communication to Niles multizone receivers, and future upgrades.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION FLEXIBILITY
With a low profile design, easy-to-access connections, and mounting wings with rack-mount
spacing, the HT-MSU can be wall-mounted behind theater components or attached to the back of
metal professional racks. The HT-MSU incorporates an infrared pass-through port allowing control
over sources that use original remotes, even if the system is hidden from view.
RELIABLE ZIGBEE® RF COMMUNICATION
The iC2 System uses a very reliable 2.4 GHz radio frequency that works extremely well even in RF
“noisy” environments. The iC2 System’s 10-channel and 16-network ID capability allows multiple
iC2 Systems to be used near each other, as well as in multiple-dwelling units like condos and
townhouses.
QUICK AND EASY SET-UP WITH WIZARD-BASED NILES
™
QUICKCONFIG PC CONFIGURATION SOFTWARE
An iC2 System configuration can be programmed, saved, and edited using the Niles QuickConfig
PC Configuration Software and Niles IR-CS Infrared Capture Station. The QuickConfig software is
wizard based and guides the installer/programmer through basic and advanced system designs.
ASSIGNABLE RELAYS AND 12V OUTPUTS
Three dry contact closures and three 12V DC trigger outputs can be independently programmed
to give installers greater control of mechanical devices or voltage-triggered power strips and
dispersion controlled home theater loudspeakers.
INTELLIGENT INTEGRATION WITH MULTIZONE SYSTEMS
The Home Theater Main System Unit includes control ports that allow the iC2 System to “share”
sources with whole-house distributed audio systems. The power state of these “shared” sources
can be completely managed so that sources are always powered-on when they need to be and
powered-off when both whole-house and home theater systems are turned off.
PROGRAM MEMORY PROTECTION
The entire system profile is stored in non-volatile memory within the HT-MSU. This safeguards
against accidental loss of the configuration programming for the entire life of the product under
normal use.
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
3
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
Check that your iC2 Home Theater Automation and Control System contains the following:
• Home Theater Main System Unit (HT-MSU)
• HT-MSU Power Supply
• iC2 Remote + Battery
• iC2 Remote Charging Power Supply
• Master Key Label Sheet
• RF Antenna
• Antenna Wall Bracket
• 10 iC2 Remote Master Key Caps
• System Configuration Worksheet
• Ferrite Bead
• 10' (3 meters) Antenna Extension Cable
• End User Guide
PARTS GUIDE
5
THE IC2 REMOTE
4
3
1
�
�
�
����
������
�
�
�
�
�
�
�
�
�
�
�
�
��
�����
���
����
��
�
���
�
���
�����
����
����
����
2
����������
Figure 1. iC2 Remote Front View
1) Master Keys - The eight Master Keys on the left side of the remote can be custom labeled
and will initiate the iC2’s automation functions when programmed via Niles QuickConfig. Pressing a
Master Key will prompt the HT-MSU to check the On/Off status of all of the components in the system
and issue the necessary commands so users can enjoy the selected source.
2) System Off Button - When pressed, the Remote will instruct the HT-MSU to check the
On/Off status of all the components in the system and issue the necessary commands to power down
the system.
3) Function Keys - These 36 Function Keys include the numeric, transport menu navigation
mute, volume and channel keys, and can be programmed to control the labeled Master Keys’ source
functions. The Function Keys can be programmed differently for each Master Key and provide
different functionality or sequences.
4) Backlight Button - This button is used to turn on the backlight for use in low light
conditions. The backlight will turn off after a short duration (about 10 seconds) and can be
programmed for activation.
5) Charging Indicator - The LED is blue when the charging power supply is plugged in and
the battery is charging normally. The LED is red if there is a problem with charging the battery.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2. iC2 Remote Bottom View
7
6
6) Reset Button - This button is used to reset the remote. Should the remote lock up and/or
not communicate with the HT-MSU, use a paper clip to access the reset button.
7) Battery Door - The battery compartment is accessed via the battery door, which is
secured with a Phillips head screw.
Figure 3. iC2 Remote Rear View
8
9
8) USB Connection - The USB connection is a diagnostic connection used by the Niles Audio
Corporation Service Center only.
9) Power Connection - This is the connection where the charging power supply connects
to the Remote. When the power supply is plugged into the wall outlet, the remote’s Master Keys
will blink three times to indicate a proper connection. The Charging Indicator LED will be blue while
the battery is charging.
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
5
Download from Www.Somanuals.com. All Manuals Search And Download.
THE HOME THEATER MAIN SYSTEM UNIT (HT-MSU)
7
1
8
10
9
2
3
13
4
6
5
11
12
Figure 4. HT-MSU Top View
1)
IR Outputs - SRC1 – SRC6, TV/7, RCV/8 are eight dedicated 3.5mm jack source flasher
outputs that output IR data specifically for that source.
2)
RS232 Outputs - SRC1 – SRC6, TV/7 and RCV/8 are eight dedicated 3.5mm jack source
serial outputs that output RS232 data specifically for that source.
3)
Assignable 12V Outputs - Three 3.5mm jacks, output 12V DC 150mA
when activated:
a. 12V outputs 1 & 2 are independent of each other and are programmable
to output 12V momentarily or constantly when activated.
b. 12V output 3 is assignable and outputs 12V constantly when active.
4)
Assignable Relays - There are three, 3-position removable quick connect plugs labeled
1, 2 and 3 for connecting either NO (normally open) or NC (normally closed) contact closure devices
to the HT-MSU.
(CONTINUED ON NEXT PAGE)
6
Download from Www.Somanuals.com. All Manuals Search And Download.
5) IR Input - A 4-position removable quick connect plug for connecting an IR sensor to the
HT-MSU. This connection allows IR control of the HT-MSU and/or IR pass-through for connected
sources.
6) Global IR Output - A 3.5mm jack provides all IR codes that the HT-MSU generates and all
IR codes that come in through the IR Input connection and can be configured via Niles QuickConfig
for Normal or High output. Normal output is designed for a Niles MF1 IR MicroFlasher®; high output
is designed for a Niles IRB1 High-Output IR Flasher.
7) RF Antenna Socket - The BNC connector accommodates the supplied antenna.
The antenna must be installed perpendicular to the ground for best results. A 10 foot (3 meter)
antenna extension cable and mounting bracket are included if remote installation of the antenna
is necessary.
8) Status 12V or Video - Six video and voltage-sensing RCA sync inputs for sources 1
through 6 detect when a source is on/off for reliable system activation.
9) Status 12V - Two voltage-sensing 3.5mm jacks for sources TV/7 and RCV/8 detect when
those sources are on/off for reliable system activation.
10) Power 12V DC - A barrel connection for the provided 12V DC power supply.
11) Diagnostic - A USB A connection for Niles Service Center.
12) PC Connection/Expansion - A RJ45 connection used to plug in a laptop computer
for system configuration programming or expanding the system design out to future Niles multizone
receivers. Niles QuickConfig is used for system configuration.
13) RF Test - A 3.5mm jack used to connect the optional Niles IR/RF tester for testing RF
reception.
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
7
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEM DESIGN CONSIDERATIONS
The Niles iC2 System is a highly flexible tool that allows system designers to create home theater
systems that will delight customers. Simplicity in operation is at the core of the iC2 System’s
design. Features like HDMI video switching surround receivers and televisions, high-definition DSS
satellite receivers, and DVD managing media servers can make home theater systems extremely
difficult to operate. The following section explains just some of the system design features of the
Niles iC2 System.
To fully understand the system configurations, it’s important to understand the basic control sec-
tions of the HT-MSU.
IR OUTPUT PORTS
IR (Infrared) codes are stored in the HT-MSU during configuration programming. The labels of the
IR Outputs identify what source number these ports are designed to operate. SRC1 means source
1. The outputs are labeled SRC1 through SRC6, TV/7 and RCV/8. If the TV is to be controlled via
IR codes, then the IR Output TV/7 port should be used. However, if the TV will be controlled via
RS232, then the TV/7 IR output can be used to control an alternate IR source. These IR outputs are
dedicated and routed, meaning IR codes stored for source number 3 (i.e. a DVD player) can only
be emitted from the IR output port labeled SRC3. RCV/8 can be used either for the receiver in the
home theater or a source number 8.
RS232 OUTPUT PORTS
RS232 is a serial device control protocol that allows sources to be controlled via a transmit-receive
cable (See the Installation section for wiring information). RS232 codes are stored in the HT-MSU
as string codes during configuration programming. The labels of the RS232 outputs identify what
source number they are designed to operate. SRC1 means source 1. The outputs are labeled SRC1
through SRC6, TV/7 and RCV/8. If the TV is to be controlled via RS232 codes, then the RS232 TV/7
port should be used. However, if the TV will be controlled via IR, then the RS232 TV/7 port can
be used to control an alternate RS232 source. These RS232 outputs are dedicated and routed,
meaning RS232 codes stored for source number 3 (i.e. a DVD player) can only be emitted from the
RS232 output port labeled SRC3. RCV/8 can be used either for the receiver in the home theater or a
source number 8.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
SOURCE POWER STATUS CONNECTIONS
To properly automate home theater sources, the HT-MSU needs to “know” when the source is
powered On or Off. There are three ways that sources are powered on:
1. Toggle Power: A source via its remote control has one button for turning that source
On and Off. When trying to automate such a device, you must provide the HT-MSU the
“Power Status” as feedback using the Status connection on the HT-MSU’s top edge
(detailed below).
2. Separate On and Off Power: A source via its remote control has one button to turn
the source On and a different button to turn the source Off. When trying to automate
such an IR device, you should provide the HT-MSU the “Power Status” as feedback so
the iC2 System will act faster using the Status connection on the HT-MSU. If a source
is to be controlled via RS232 and it has separate On and Off codes, you do not need to
provide the HT-MSU feedback.
3. Latching Power: Latching power is an industry term that means the source has no
power command/s on its remote control. A latching power source may have a “hard”
power button on the front panel. To determine if a source is latching power, push its
“hard” power button in, take its power cord and plug it into a live AC power outlet. If it
turns on when plugged into the outlet and turns off when unplugged from the outlet,
it is a latching power source. Latching power sources do not need a Power Status
connection, but you will want to do one of two things:
a. Plug it into the switched outlet of the receiver, or
b. Use a Niles AC-3 Voltage Triggered Power Strip connected to one of the
assignable 12V outputs on the HT-MSU. Use the QuickConfig Software to
program the assigned 12V output to turn on when that source is selected.
(See QuickConfig manual for more details on programming 12V outputs.)
Along the top edge of the HT-MSU are the source-specific status connections labeled
SRC1 through SRC6. These RCA jacks are designed to sense either 12 Volts or video
so the HT-MSU “knows” when the source is On or Off. You must use these connections
if the source you are trying to automate is IR controlled and uses toggle power
(see 1.Toggle Power above).
If the source has a video out jack, connect the video output to the corresponding SRC
Status RCA jack on the HT-MSU. If the source has no video output jack, you may use
one of the Niles external-sensing devices that provides 12V output (i.e., the CS12V
Current Sensor or the LS-1 Light Sensor) connected to the RCA Status jack.
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
9
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSIGNABLE 12 VOLT OUTPUTS
These three ports are completely assignable and can be used to trigger out-board automation
devices such as:
• 12V Triggered AC Power strips like the Niles AC-3
• 12V Triggered subwoofers like the Niles SW300, SW12, SW10, and Pro15SW
• 12V Triggered Dipole/Bipole rear effects speakers like the StageFront IW650FX
• Motorized drapery systems and projection screens
12V Output #1 has a default setting to output 12V DC whenever the home theater receiver is turned
on by the HT-MSU Master Key activity setting.
12V Output #2 has a default setting to output 12V DC whenever the HT-MSU Master Key activity
setting turns on the TV.
12V Output #3 has no default and is completely assignable.
The three assignable 12V outputs can be configured (programmed) using the Niles QuickConfig
Software.
ASSIGNABLE RELAYS
There are three independently assignable dry contact closures/relays. These connections can be
used to trigger lights, curtains, screen lifts, and other devices. Use the Normally Open or Normally
Closed side of the contact closure to complete the circuit to control the device.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEM CONFIGURATION 1
SINGLE TV WITH A COMBINATION OF IR AND RS232 CONTROLLABLE SOURCES
Flat Panel Display
HT Receiver
Satellite Receiver
Media Server
CS12V
12VDC Power
Supply
DVD Player
Portable Docking Station
CD Disc Changer
HT-MSU
WS110
Motorized Lift
Flasher
RF ZigBeeAntenna
12 Volt
RS232
AC-3
2 Conductor
Video Synch
Figure 5.
System Configuration 1
iC2 Remote
Remote
In System Configuration #1 (Figure 5), the flat panel TV is controlled via the RS232 connection
TV/7 on the HT-MSU. A motorized lift to raise and lower the TV is being activated using the pro-
grammable assignable Relay #1. The surround receiver is being controlled via IR flasher connected
to the RCV/8 connection on the HT-MSU. The surround receiver’s power status is being monitored
by a Niles 12V DC power supply plugged into the receiver’s switched AC outlet and then plugged
into RCV/8 Status 12V connection on the HT-MSU. In addition to the TV and receiver, there are five
sources. The DSS Satellite receiver is being controlled via IR from the IR SRC1 port. There is no
status connection to the HT-MSU because it has separate On/Off codes. The Media Server is being
controlled via the RS232 SRC2 port. The DVD player is being controlled via the IR SRC3 port, and a
CS12V Current Sensor connected to the SRC3 Status RCA jack is providing the status. IR connected
to the IR SRC4 is controlling the portable Music Player in its dock, and video is providing the status
connected to the SRC4 Status RCA jack. IR connected to the IR SRC5 port is controlling a latching
power CD player and, using the 12V Output # 1, triggering a Niles AC-3 to power it On and Off.
A Niles IR sensor is connected to the IR sensor input so the customers can still use the original
remote to control the media server.D
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
11
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEM CONFIGURATION 2
DUAL TV MODE AND INTEGRATION WITH AN IR CONTROLLED MULTIZONE RECEIVER
HT Receiver
Flat Panel Display
Portable Docking Station
12 V DC
Power
Supply
Projector
RS232 Controllable
Listing System
Motorized Projection Screen
RF ZigBeeAntenna
HT-MSU
CS12V
Multizone Receiver with IR Interface
iC2 Remote
See Figure 7
DVD Player
Flasher
12 Volt
RS232
TiVo®
Video Synch
Figure 6. System Configuration 2
System Configuration #2 (Figure 6) demonstrates the Dual TV Mode feature of the iC2 System.
The flat panel TV is controlled via RS232 on the HT-MSU RS232 TV/7 port. This is considered the
default TV. The customer also has a projector and screen used only when the theater room is dark.
The projector is configured (programmed) with Niles QuickConfig Software to be TV2 and is wired
for IR control to the HT-MSU IR SRC1 port. The Status of TV2 is connected to the HT-MSU IR SRC1
RCA connection using the 12V output of the projector (usually used to trigger the screen). The
projection screen is being triggered by the HT-MSU 12V Output #3. When the first Master Key on
the iC2 Remote is pressed from an all off mode, the default TV (the flat panel TV, TV1) is turned
on. Master Key 8 is labeled SWAP TV. When the SWAP TV Master Key is pressed, TV1 (flat panel) is
turned off and TV2 (the projector) is turned on, and the screen is lowered for viewing. The Dual TV
Feature is not limited to IR controllable TVs. Either TV can be RS232 controllable.
NOTE: IN DUAL TV MODE, ONLY ONE TV IS ON AT A TIME. BOTH TVS CANNOT BE ON AT THE SAME TIME.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration #2 also shows an RS232 controllable lighting system connected to the
HT-MSU RS232 SRC6 port. In this configuration, there are 2 sources (a DVD and a DSS satellite
receiver) being “shared” with the house-wide multizone distributed audio receiver. The HT-MSU
sends IR codes for both of the shared sources out of the Global IR Output port into the multizone’s
IR IN port. The HT-MSU’s 12V Output #1 is connected to the multizone’s HT SYNC port, which
ensures that the “shared” sources are turned On and Off correctly. The multizone “knows” that the
home theater system is On or Off via this 12V connection.
SYSTEM CONFIGURATION 3
TV ARRAY MODE AND INTEGRATION WITH A RFG
Flat Panel Displays
HT Receiver
Satellite Receiver
Media Server
12 V DC
Power Supply
Flat Panel Display
CS12V
DVD Player
PAR4
RFG
Flasher
12 Volt
RF ZigBee Antenna
HT-MSU
RS232
CAT-5 Cable
iC2 Remote
Figure 7. System Configuration 3
System Configuration #3 (Figure 7), shows two more system design features of the iC2 System.
The iC2 System has a design feature called TV Array. Here, a Niles PAR4 Simplified IR Router is
used with the HT-MSU to control an array of identical televisions.
NOTE: IN ORDER TO USE THE TV ARRAY FEATURE, ALL OF THE TVS NEED TO BE IDENTICAL OR
RESPOND TO THE SAME IR CODES. ADDITIONALLY, THE TVS MUST HAVE SEPARATE ON AND OFF
POWER COMMANDS AND DIRECT ACCESS INPUT COMMANDS.
A Niles 3.5mm to 3.5mm cable connects the PAR4 to the HT-MSU’s IR TV/7 port. On the Niles
PAR4, Niles MicroFlashers are connected to the numbered outputs 1 through 4. The main TV should
be connected to the PAR4 #1 output. When the end user presses any Master Key from an All Off
situation, the Main TV (PAR4 #1) turns on. Master Key 8 is labeled TV Array. Press the TV Array
Master Key (Master Key 8), then press one of the number keys 1, 2, 3 or 4. This allows the end user
to control that TV in the array of TVs. Two Niles PAR4s can be used for a maximum of 8 TVs in the
TV array.
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
13
Download from Www.Somanuals.com. All Manuals Search And Download.
The final design feature in System Configuration #3 uses a Niles Radio Frequency Gateway (RFG)
to extend the antenna away from the HT-MSU. The Niles iC2 HT-MSU comes with an RF antenna
that can be connected directly to the HT-MSU antenna socket. Reception range is approximately 75
feet (22.86 meters). We recommend using the 10 foot antenna extension cable to position the RF
antenna away from the home theater sources. Use the extension cable and the antenna bracket to
get the antenna up and away from all of the products that can cause interference with RF reception.
Keep in mind that the reception range may not be enough if all of the home theater gear is located in
another room further away than 75 feet (22.86 meters). A Niles RFG is an optional device that can be
used to move the RF radio antenna up to 330 feet (100 meters) away from the HT-MSU. The RFG is
connected to the HT-MSU via CAT-5 cable. (Please refer to the Installation Section for the importance
of terminating CAT-5 cable with the T568A standard). Niles QuickConfig Software will ask if a Niles
RFG is being used to aid in set-up.
INSTALLATION CONSIDERATIONS
PLACEMENT OF THE HT-MSU
Niles recommends placing the HT-MSU conveniently close to the equipment it is controlling.
Generally, the unit should be placed in a concealed location because its indicator and connections
are only used during installation. Placement possibilities include:
1) Wall-mount (affixed to the back of the equipment cabinet or a nearby wall) (Figure 8)
2) Rack-mount (attached to the back of a professional 19-inch standard equipment rack that
uses traditional 1, 2 or 3 “u” hole spacing (e.g. Middle Atlantic)
3) Table-top (on the floor or shelf behind the equipment)
ANTENNA CONSIDERATIONS
Communication between the iC2 Remote and the HT-MSU is an RF-based with a frequency of 2.4
GHz. Effective range of the iC2 Remote to HT-MSU communication is 75 feet (22.86 meters) open
air. The RF antenna can be attached directly to the HT-MSU with the provision that the antenna is
vertical for best reception.
Figure 8. Wall-mount placement
Figure 9. Vertical alignment of
antenna is necessary
Use sheetrock screws
for optimal reception
14
Download from Www.Somanuals.com. All Manuals Search And Download.
The HT-MSU is supplied with a 10 foot antenna extension cable to allow the antenna to be placed
away from the HT-MSU. An antenna wall-bracket is also supplied so the antenna can be attached
high on the wall behind the equipment.
NOTE: HOME THEATER EQUIPMENT, DIGITAL SOURCES AND RACKS ARE MADE OUT OF METAL AND CAN CAUSE
INTERFERENCE OR “SHADOWS” IN RF RECEPTION. NILES HIGHLY RECOMMENDS YOU PLACE THE ANTENNA AS
HIGH AS POSSIBLE AND AWAY FROM THE MAIN SOURCE GEAR AND EQUIPMENT RACK.
The Niles Radio Frequency Gateway (RFG) is available as an option and can be used instead of the
supplied antenna. The RFG allows the “radio antenna” to be placed up to 330 feet (100 meters)
away from the HT-MSU. It can also be used if the HT-MSU (and home theater gear the HT-MSU is
controlling) is further than the effective range of communications (75 feet/22.86 meters open air).
WIRING CONSIDERATIONS
The HT-MSU requires several different types of wires runs:
1) Antenna Cable: The supplied extension cable is 10 foot long and is a RG59 CL rated
cable so it can be run through the wall. Extending the cable or using longer cable is not
recommended as this will drastically affect the RF reception.
2) Flasher Cable: Niles infrared flashers (not supplied with the iC2 System) include a 10
foot cable. Flasher wires can be extended up to 200 foot (61 meters) using 2-conductor
22 gauge (“zip-cord”). Shielding is not necessary for a flasher.
3) RS232 Cable: The HT-MSU can control home theater sources using one-way RS232
control cable. Niles does not supply RS232 cables. Home theater sources that are
RS232 control capable will usually supply or recommend the wire and the pin-out that
will control their devices. Traditionally, RS232 one-way communication can be sent
over three wires (transmit, receive and ground), but not for very long distances. (Niles
recommends placing the HT-MSU in close proximity to the sources it is controlling.)
4) Status Wiring: The Niles HT-MSU has status (power synchronization) ports for eight
home theater sources. The status connections for sources 1 through 6 (labeled SRC1
– SRC6) are RCA jacks that can sense video or a 12V DC voltage signal. The TV/7 and
RCV/8 (receiver) status connections are 3.5mm jacks that sense voltage signals. When
using video for status, a standard RCA cable can be used from that source. Alternatively,
when using 12V for status, a standard 22 gauge, 2-conductor cable (“zip-cord”) can
be used. Niles Accessory Cables (FG00724 or FG00933) can also be used (SEE THE
ACCESSORIES SECTION FOR MORE INFORMATION).
TECH TIP
WIRE SIZE IS EXPRESSED BY ITS AWG (AMERICAN WIRE GAUGE) NUMBER – THE LOWER THE
NUMBER, THE LARGER THE WIRE, FOR EXAMPLE, 20 AWG IS PHYSICALLY LARGER THAN 22 AWG.
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
15
Download from Www.Somanuals.com. All Manuals Search And Download.
5) 12V Output and Relay Wiring: The HT-MSU has three 12V and three “Dry Contact
Closure” Relay Outputs that can activate mechanical devices such as motorized drapery
and projection screen systems, as well as a number of other automation devices. For
each device these outputs will control, standard 22 gauge 2-conductor cable (“zip-
cord”) can be used. Niles Accessory Cables (FG00724 or FG00933) can also be used
(SEE THE ACCESSORIES SECTION FOR MORE INFORMATION).
6) IR Sensor Wire: The HT-MSU has
an infrared (IR) sensor input for
connection to any type of Niles
IR sensor. Niles IR sensors utilize
4-conductor wiring and have been
designed for use with CAT-5 cable
(4-pair twisted) (Figure 10).
7) Expansion Cable: The HT-MSU has
an Expansion connection that can be
used to extend the built-in RF radio
away from the HT-MSU and/or for
connection to and “sharing” sources
with future Niles multizone receivers
(SEE SYSTEM CONFIGURATION
Figure 10.
Home run the sensor
cable from the sensor
to the HT-MSU
#3 IN THE SYSTEM DESIGN
CONSIDERATIONS SECTION). This
cable must be CAT-5 terminated with
RJ45 connectors (T568A TERMINATION
PROTOCOL IS SHOWN IN THE INSTALLATION SECTION 7).
PROGRAMMING PREPARATIONS AND WORKSHEET
The HT-MSU has a PC Configuration/Expansion port on the bottom edge that is used for configuring
(programming) the system. The use of this port for configuration will be based on one of the
following scenarios:
1) If the HT-MSU is being used by itself, the PC Configuration/Expansion port will be empty
and used to program the system (Figure 11).
2) If your iC2 System design involves a Radio Frequency Gateway (RFG), CAT-5 cable will
already be plugged into the PC Configuration/Expansion port and that cable would be
plugged into the “Keypad” connection port of the RFG. Connect a CAT-5 cable to the “System”
connection port of the RFG. Programming the iC2 System and the RFG is now accomplished
“through” the RFG (Figure 12).
(CONTINUED ON NEXT PAGE)
16
Download from Www.Somanuals.com. All Manuals Search And Download.
3) If your system design involves a RFG and sharing sources with a future Niles multizone
receiver (see System Configuration #3 in the System Design Considerations section), the
programming connection must be made on a future Niles multizone receivers’ Communication
and Control connection ports. Configuration of the entire system can be accomplished with one
connection and the Niles QuickConfig Configuration wizard-based software “through” future
Niles multizone receivers.
A Worksheet is provided with the iC2 System and should be used to organize all of the information
an installer will need to configure the iC2 System. The iC2 System worksheet is also available on
the Niles website: www.nilesaudio.com
Figure 11. PC connection for programming
HT-MSU
LAPTOP
CAT-5 CABLE
Figure 12. PC connection for programming when using optional RFG.
HT-MSU
LAPTOP
CAT-5 CABLE
System Port
Keypad Port
RFG
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
17
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Before you begin, make sure that all of the cables and wires, as well as the power supply cable will
reach the proposed location of the HT-MSU. Mark the cables with labels that describe where the
cable originates (rather than which terminal on the HT-MSU it connects to).
STEPS:
1) IC2 REMOTE BATTERY
The iC2 Remote rechargeable battery needs to be connected and charged. The installer
needs to remove the battery cover with a Phillips screwdriver. The plug on the battery is
keyed and only allows it to be plugged in one way. Plug in the battery and position it in
the compartment next to the positioning foam.
2) LABEL THE MASTER KEYS ON THE IC2 REMOTE
�
The Master Keys on the iC2 Remote can be labeled using the
supplied label sheet and plastic key caps. The iC2 worksheets
should be filled out prior to labeling the Master Keys. Based on
��
the worksheet, peel off the appropriate label from the sheet and
place it on the corresponding Master Key. The plastic key caps are
����������
molded with one end rounded and the other flat. Orient the key
cap correctly over the Master Key; push the key cap down on the
Figure 13.
iC2 Remote’s 8 custom
label Master Keys
Master Key until it sits flush with the molded portion of the iC2
Remote.
3) CONNECT THE CHARGING POWER SUPPLY
The rechargeable battery for the iC2 Remote may still have a charge, but we recommend
plugging the iC2 Remote to the charging power supply. The iC2 System comes with two
identical power DC power supplies. Choose one of them and plug the outlet-plug end into
an unswitched AC outlet. Pass the power cable through the supplied ferrite bead, wrap
the cable around the bead twice, leaving the power plug as you clip the bead closed.
Figure 14. Ferrite bead on iC2 Remote power supply cable
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Plug the barrel end into the back of the iC2 Remote. When the power supply has been
properly plugged in, the backlighting for the buttons will flash twice and the charging LED
will turn blue to indicate that the battery is charging. When the battery has a full charge,
the LED will not light. If the charging LED lights red, there is a fault with the battery. If this
happens, unplug the power supply, wait two minutes, and re-plug in the power supply. If
the LED is still red, contact Niles Service Center.
4) CONNECT POWER TO THE HT-MSU. CHECK LED, DISCONNECT POWER
Plug the supplied 12V DC power supply into an unswitched AC outlet. Plug the connector
into the socket marked “Power” on the HT-MSU. If the Power LED does not light, test the
unswitched AC outlet with another appliance. If the outlet tests OK, you have a defective
power supply, which must be replaced for you to continue. Once you have completed
the power supply test, unplug the power supply and continue hooking up the rest of the
wires and cables.
5) CONNECT ALL FLASHERS
Route the connecting wire to the HT-MSU. Connect
the 3.5mm mono plug into the corresponding SRC jack
labeled “IR Output” from the installation worksheet.
If you need to extend the wire, use a 2-conductor 16
gauge or larger (SEE “TECH TIP ON PAGE 15).
Figure 15.
Flasher connection on HT-MSU
6) CONNECT ALL RS232
The RS232 Output jacks use 3.5mm STEREO plug with standard TRS (Tip, Ring and
Sleeve) configuration of Transmit, Receive, and Ground. This may require the installer
to custom make the connection to the corresponding source. Most RS232 controllable
sources use one of the following as its RS232 input connector:
a) A Male DB9 connector
b) A Female DB9 connector
c) A 3.5mm stereo input jack
Ring
Female
Male
Sleeve
Tip
Figure 16. 3.5mm stereo plug and DB9 connectors
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Most sources that are RS232 controllable provide a protocol document (usually from their
Tech Support Department) that will have all of the necessary information, including pin-out,
to custom build the RS232 control cable (Figure 16).
7) CONNECT ALL STATUS
There are two types of status (power synchronization) ports on the HT-MSU: the TV/7
and RCV/8 status connections are 3.5mm mono ports; and SRC1 through SRC6 status
connections are RCA jack ports. The TV/7 and RCV/8 status connections are voltage-
sensing ports “looking for” 12V DC Volt input. The most common technique for “synching”
the home theater receiver is to use a Niles 12V (FG01035) power supply plugged into the
receiver’s switched outlet, and plugging the 3.5mm jack into the RCV/8 Status connection
port. The most common way to “synch” the TV (which usually doesn’t have a switched AC
outlet on the back) is to use one of the Niles synching accessories like the CS12V Current
Sensor or LS-1 Light Sensor. Both of these synching accessories have 12V outputs that
can be connected to the HT-MSU using a 3.5mm mono jack plugged into the TV/7 status
port.
The SRC1 through SRC6 RCA connections are RCA jack ports that are “looking” for either
voltage or a video signal from the source. If a DVD is to be hooked up as SRC2 (use the
worksheets to help with source connection layouts), an RCA video cable would be used to
connect the DVD’s composite video output to the SRC2 RCA Status connection port. If the
DVD has only one composite video output, and that is being used to show video on the TV,
an RCA Y-adaptor can be used to split the video output (of the DVD) for both the TV signal
and Status connection to the HT-MSU.
IMPORTANT NOTE: RCA SOURCE STATUS INPUTS ARE DESIGNED WITH HIGH-INPUT
IMPEDANCES IN ORDER TO PRESERVE THE QUALITY OF THE VIDEO SIGNAL WHEN USING
A RCA Y-ADAPTOR.
If the source to be “synched” doesn’t have a video output, one of the Niles Synching
Accessories can be used instead of video. Most Niles Synching Accessories use a 3.5mm
jack as the output. This 3.5mm jack must be changed to mate with the RCA connector on
the HT-MSU; use a Radio Shack 274-897 OR 274-330 mini-plug to male RCA adapter.
8) CONNECT 12V
The 12V trigger output jacks use 3.5mm mono plug with standard “Tip and Collar”
configuration. The tip is 12V DC 150mA when activated and the collar is ground. Niles has
two accessory cables for use with these 12V output jacks (FG00724 or FG00933). Simply
plug one of these cables with a 3.5mm mono plug into one of the three assignable jacks.
Plug the other end of the cable into the device that will be triggered or activated.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
The Niles QuickConfig Software is used to assign (program) the functionality of these
jacks. The configuration software allows the 12V output to be programmed as follows:
a) Output #1 can be configured to output 12V constantly or momentarily. A
momentary output would be used to activate a device that requires a pulse
of 12V instead of a constant 12V. The pulse can be programmed for 1, 3
or 5 seconds, then off when activated. The constant mode will output 12V
continuously when activated, and no 12V when deactivated.
b) Output #2 can be programmed just like Output #1, but completely
independent of output #1.
c) Output #3 configured for constant output only when activated,
but is also completely independent of outputs 1 and 2.
Please refer to the Niles QuickConfig Configuration manual for more information about
the 12V output programmability.
9) CONNECT RELAYS
The “Dry Contact Closure” relays use 2-conductor wire to pair
either the NO “Normally Open” or NC “Normally Closed” side of
the removable connector plug with the “Common”. NO or NC is
determined by which device you are triggering. Strip 1/4 inch of
N
N
O
R
M
A
L
C
O
M
M
O
N
the insulation from the end of each wire, and tightly twist the end
of each wire until no frayed ends remain. Use a small flathead
screwdriver or your fingernail to raise the locking tabs, exposing
the holes on the removable connector. Insert each wire into the
appropriate hole on the removable connector plug (Figure 17)
and snap the locking tab down. To help you, the connector plug
is keyed. Insert the smooth side of the connector plug into the
smooth side of the socket.
O
R
M
A
L
L
Y
L
Y
C
L
O
S
E
D
O
P
E
N
Figure 17.
Relay removable
connection plug
10) CONNECT THE SENSOR CABLE TO IR INPUT
Strip 1/4 inch of the insulation from the end of each wire. Tightly
twist the end of each wire until no frayed ends remain. Use a
small flathead screwdriver or your fingernail to raise the locking
tabs, exposing the holes on the removable connector. Insert each
wire into the appropriate hole on the removable connector plug
(Figure 18) and snap the locking tab down. To help you, the
connector plug is keyed. Insert the smooth side of the connector
plug into the smooth side of the socket.
Figure 18.
HT-MSU sensor
removable
connection plug
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
21
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
11) CONNECT ANTENNA
To attach the RF antenna to the HT-MSU, push the antenna down
on the antenna socket of the HT-MSU and twist to the right (you
will feel a click or stop when the antenna is completely on).
12) EXTEND AND MOUNT THE ANTENNA
Niles supplies a 10 foot extension cable and antenna bracket for
mounting the antenna away from the home theater sources. Make
sure the antenna extension cable will reach the antenna mount
without snagging or twisting with the other cables needed for the
HT-MSU. If you’re mounting the HT-MSU to the back of the metal
professional equipment rack that slides-out (for easy access
to the wires), make sure that, when the rack is fully extended,
the antenna extension cable will reach without being stretched
or pinched when the rack is slid back into place. To attach the
antenna extension cable to the HT-MSU, push the connector down
on the antenna socket of the HT-MSU and twist to the right (you
will feel a click or stop when the connector is completely on).
Figure 19.
Vertical alignment of
antenna is necessary
for optimal reception
Use a pencil to mark the location of the antenna bracket. (Figure
19)Then, use two dry-wall screws to attach the antenna bracket
to the mounting surface. Unscrew the nut from the antenna end
of the antenna extension cable; put the antenna connector end
through the hole in the bracket. Attach the nut back on the antenna
connector end of the cable to tighten the cable to the bracket.
Attach the RF antenna to the connector/wall bracket combo; twist
to the right (Figure 20). You will feel a click or stop when the
antenna is completely on.
Figure 20.
Antenna connection
to “L” Bracket
13) CONNECT EXPANSION CAT-5 CABLE
1 = GREEN/WHITE
If connecting the HT-MSU to a Niles Radio
Frequency Gateway instead of attaching
the supplied antenna (SEE THE SYSTEM
DESIGN CONSIDERATION SECTION,
2 = GREEN
3 = ORANGE/WHITE
4 = BLUE
5 = BLUE/WHITE
6 = ORANGE
CONFIGURATION #3), use CAT-5 cable
terminated with RJ45 connection plugs.
The CAT-5 cable must be terminated using
the T568A standard wiring (Figure 21).
7 = BROWN/WHITE
8 = BROWN
Figure 21. T568A wire termination
14) RE-CONNECT POWER TO THE HT-MSU
You are now ready to program the Niles iC2 System.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
The iC2 System is a configurable system (i.e., the product arrives “empty” and must be
programmed by the installer). Troubleshooting generally occurs after the iC2 is programmed;
however, the iC2 System can be divided into two main areas, and some troubleshooting can occur
prior to programming:
1) Hardware Issues
2) Programming (refer to the Niles QuickConfig Configuration Software Manual for more
information on programming troubleshooting)
HARDWARE ISSUES
There are three basic issues that can prevent proper operation of the iC2 system. These issues are
presented in the order of probability and are as follows:
PROBLEM:
1. Bad Connections or Wiring
If the connections or wiring are wrong, loose, shorted or open, the system will not
operate properly. The symptoms could include: Power LED flickers or is off, IR/RF Test
LED is continuously flickering or on without any iC2 remote use, intermittent operation
or no operation.
SOLUTIONS:
• Test your power supply connections
• Test your Flasher connections
• Test your Sensor connection
• Test your cable for shorts and opens
2. RF or Electromagnetic Interference
Digital sources, poorly shielded sources, cordless telephones, cell phones, high-
definition television sets, light dimming controls and other sources of electromagnetic
fields can induce radio frequency noise and interference into your home theater
automation system. The symptoms could include:
GREEN LED
RED LED
Flashback LEDs on IR/RF Tester continuously flickering or
on without any iC2 remote use, poor range, intermittent
operation or no operation.
The Niles IR/RF Tester (stock number FG00727) is a
troubleshooting tool to aid in diagnosing hardware issues
3.5MM PLUG
with the iC2 System (Figure 22). It is not required for
operation and, therefore, is sold separately. The IR/RF
Tester has two LEDs (one red, one green) and can be
plugged into IR Output ports to diagnose whether or not
the HT-MSU is issuing IR codes out of individual ports.
Figure 22.
Niles IR/RF tester
FG 00727
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
23
Download from Www.Somanuals.com. All Manuals Search And Download.
[This can also be accomplished using Niles MicroFlashers that provide visible feedback
(see the Accessories section for more information).] The IR/RF Tester can also be
plugged into the RF Test port to verify that the HT-MSU is receiving and sending RF
information from the iC2 Remote. Plug the IR/RF Tester 3.5mm jack into the RF Test
port. Place the LED housing with the two LEDs where it can be seen. The green LED
on the IR/RF Tester should flicker when a button is pressed on the iC2 Remote. The
red LED should flicker when the HT-MSU sends information back to the iC2 Remote. If
either the LED on the IR/RF Tester stays lit, there may be RF interference. Disconnect
the antenna from the HT-MSU to see if the LEDs go out.
3. Source Powering On or Off Incorrectly
To automate sources correctly, the HT-MSU requires status feedback from sources
that have a single-toggle power command. The HT-MSU either “sees” or doesn’t “see”
control signals at the Status ports. If the HT-MSU sees improper or intermittent status
feedback (i.e., the HT-MSU may “think” that the source is off when it may really be
powered on), the operation of the iC2 System is compromised.
The symptoms could include: sources staying on when the System Off button is
pressed; a source turns on for a Master Key and off when that Master Key is pressed
again; and sources not turning on at all. The most important tool for troubleshooting
this issue is knowledge. Knowing the functionality of the sources being used with
the iC2 System is paramount. For example, we know that most DVD players require
choosing composite/component video output, even digital HDMI or DVI output. When
set for component or digital video output, the composite video output is sometimes
disabled. If a DVD player is set for digital video output and it disables the composite
video output, you cannot use the composite video output for status connection to the
HT-MSU. Because there will never be a signal at the composite output, the HT-MSU will
think that the DVD is always off and issue the power command. This will cause the DVD
player to be turned on the first time a Master Key is pressed and turned off the second
time the same Master Key is pressed.
Status feedback is tested when configuring the iC2 System using the Niles QuickConfig
Software. After the transfer screen in the software, there is a Functionality Test Screen
that allows the software to test the configuration stored in the HT-MSU while providing
feedback on the screen of the programming laptop. The feedback provided is real-time
status feedback for Status Ports SRC1 through SRC6 as well as the TV/7 and RCV/8
ports. The Functionality Test Screen also allows for feedback on the Assignable 12V
Output and relay ports.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
FLASHERS
MF1 IR MICROFLASHER
FG01019
MS110 FLUSH MOUNT IR SENSOR
FG01409
10’ cable with a 3.5mm plug.
Flush-mount infrared sensor used
Includes elastomer-style blocking
cover for curved surfaces
for IR pass-through on HT-MSU
MS210 MINIATURE SURFACE-MOUNT
IR SENSOR
MF1VF IR MICROFLASHER
FG01020
FG01410 - Silver
FG01411 - White
FG01412 - Black
10’ cable with a 3.5mm plug
Flush-mount infrared sensor used
for IR pass-through on HT-MSU
®
IRB1 HIGH-OUTPUT IR FLASHER
FG01023
TRIGGERING ACCESSORIES
IR Flasher can be mounted inside
of cabinets or on top of equipment
rack. Can control entire stack of
A/V components
AC-3 VOLTAGE-TRIGGERED AC POWER STRIP
FG00242
AC power strip with two-voltage
triggered AC outlets and one
unswitched AC outlet
SENSORS
TS110 TABLE TOP IR SENSOR
FG01413
3.5 MM TO 3.5MM CABLE
FG00933
Tabletop infrared sensor used for
IR pass-through on HT-MSU
10ft. cable with 3.5mm mono
mini-plug that can be used as
a trigger accessory or a direct
flasher connection
WS110R WALL-MOUNT IR SENSOR
FG01414 - White
FG01415 - Bone
FG01416 - Almond
3.5MM TO FLYING LEADS
FG00724
FG01417 - Black
Wall-Mount infrared sensor used
for IR pass-through on HT-MSU
10ft. cable with 3.5mm mono mini-
plug to 3.5mm mono mini-plug and
two flying leads
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
25
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES (CONTINUED)
EXPANSION ACCESSORIES
PAR4 SIMPLIFIED INFRARED ROUTER
FG01172
CS12V CURRENT SENSING 12 VOLT TRIGGER
FG01173
Activates voltage controlled
devices by turning on another
component. Current-sensing
makes it compatible with any 110V
electrical device
Routes IR commands to four
components. Compatible
with all brands of A/V equipment
and remote controls. Used for iC2
TV Array feature
LS-1 LIGHT SENSOR
FG00728
RADIO FREQUENCY GATEWAY (RFG & RFG EX)
FG01407 NORTH AMERICA
FG01408 INTERNATIONAL
Senses the brightness of a
component’s front-panel display
and outputs a 12V DC sync signal
when the display is brightest
An optional device that can be
���
����������������
�������
used instead of the supplied
antenna; allows the Zigbee radio
antenna to be placed up to 100
meters (330 feet/100 meters)
away from the HT-MSU
APC-2 CURRENT-SENSING OUTLET SWITCHER
FG00254
Accessory 12Volt DC power
adaptor. Provides enough current to
trigger up to six automated
switchers; also used for status on
receivers with switched outlets
1.25A 12VDC UNIVERSAL POWER SUPPLY
FG01035
Current outlet provides 12V DC
sync connection via an accessory
cable to the HT-MSU
IR/RF TESTER
FG00727
Dual LED design visually confirms
the receipt of a valid RF command
at the MSU
26
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
HT-MSU
IC2 REMOTE
Power Requirements: 12VDC 1.25A Regulated
Power Requirements: 12VDC 1.25A Regulated
In-line Power Supply (included)
In-line Power Supply (Included)
Unit Dimensions: 10.52”L x 5.85”W x 1.01H
Battery: Rechargeable L-ION 3.75 volts 3500
(26.72 cm x 14.86 cm x 2.57 cm)
amp/hours
Full Charging Cycles to 80% battery
RF Section: 2.4-GHz frequency ZigBee wireless
effectiveness: 550
mesh technology
Unit Dimensions: 7.45”L x 5.22”W x 2.96”H
Signal Range: 75 to 100 feet open air
(18.92 cm x 13.26 cm x 7.51 cm)
(22.86 to 30.48 meters)
RF Section: 2.4-GHz frequency ZigBee wireless
mesh technology
Wiring Requirements: RG59 CL Antenna Cable
(included), CAT-5 cable, 3 conductor 22-gauge
cable, and 2 conductor 22-gauge cable
Signal Range: 75 to 100 ft open air
Trigger Output Voltage: Three assignable
outputs at 12VDC 150mA
(22.86 to 30.48 meters)
Contact Closures: Three assignable Normally
Open/Normally Closed contact closures rated to
handle 12V @ 5 Amps each
GENERAL
iC2 System Shipping Weight: Approximately 7 lbs.
(3.18 kg)
IR Ports: 8 Routed IR Flasher Ports and 1
Routable Global IR Output Port
Warranty: Two-year limited
Agency Certifications: Tested to UL/EN60065
for US, Canadian and EU markets.
RS232 Ports: 8 Routed RS232 Output Ports
IR & RS232 Code Memory: 4000 commands
depending on brand type and model of source
This device complies with part 15 of the FCC
Rules. Operation is subject to the following
two conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation. FCC and CE approved.
Sequence capability: 450 thirty-two step
sequences
Sequence Delays: .1 to 20.0 seconds per step
Component Synchs: 8 Power Status Synch
ports rated to sense 12V 150mA input signals
or video voltage
IR Bandwidth: Compatible with virtually all
brands of remotes using carrier frequencies
between 26 and 105KHz
NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 305-238-4373
27
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED WARRANTY
NILES AUDIO CORPORATION (“NILES”) WARRANTS ITS ACTIVE PRODUCTS (THOSE REQUIRING AC OR BATTERY
POWER) TO THE ORIGINAL PURCHASER TO BE FREE OF MANUFACTURING DEFECTS IN MATERIAL AND
WORKMANSHIP FOR A PERIOD OF TWO YEARS FROM DATE OF PURCHASE.
THIS WARRANTY IS SUBJECT TO THE FOLLOWING ADDITIONAL CONDITIONS AND LIMITATIONS. THE WARRANTY
IS VOID AND INAPPLICABLE IF NILES DEEMS THAT THE PRODUCT HAS BEEN USED OR HANDLED OTHER THAN IN
ACCORDANCE WITH THE INSTRUCTIONS PROVIDED BY THE MANUFACTURER, INCLUDING BUT NOT LIMITED TO
DAMAGE CAUSED BY ACCIDENT, MISHANDLING, IMPROPER INSTALLATION, ABUSE, NEGLIGENCE, OR NORMAL
WEAR AND TEAR, OR ANY DEFECT CAUSED BY REPAIR TO THE PRODUCT BY ANYONE OTHER THAN NILES OR
AN AUTHORIZED NILES DEALER.
TO OBTAIN WARRANTY SERVICE, TAKE THE UNIT TO THE NEAREST AUTHORIZED NILES DEALER, WHO WILL
TEST THE PRODUCT AND IF NECESSARY, FORWARD IT TO NILES FOR SERVICE. IF THERE ARE NO AUTHORIZED
NILES DEALERS IN YOUR AREA, YOU MUST WRITE TO NILES AND INCLUDE YOUR NAME, MODEL AND SERIAL
NUMBER OF YOUR UNIT, ALONG WITH A BRIEF DESCRIPTION OF THE PROBLEM. A FACTORY RETURN
AUTHORIZATION NUMBER WILL BE SENT TO YOU. DO NOT RETURN ANY UNIT WITHOUT FIRST RECEIVING
WRITTEN AUTHORIZATION AND SHIPPING INSTRUCTIONS FROM NILES.
IF THE ABOVE CONDITIONS ARE MET, THE PURCHASER’S SOLE REMEDY SHALL BE TO RETURN THE
PRODUCT TO NILES, IN WHICH CASE NILES WILL REPAIR OR REPLACE, AT ITS SOLE OPTION, THE DEFECTIVE
PRODUCT WITHOUT CHARGE FOR PARTS OR LABOR. NILES WILL RETURN A UNIT REPAIRED OR REPLACED
UNDER WARRANTY BY SHIPPING SAME BY ITS USUAL SHIPPING METHOD FROM THE FACTORY (ONLY) AT
ITS EXPENSE WITHIN THE UNITED STATES OF AMERICA. THERE ARE NO OTHER WARRANTIES, INCLUDING
WITHOUT LIMITATION, EITHER EXPRESS OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, WITH RESPECT TO THE PRODUCT.
REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE
CONSUMER/PURCHASER. NILES SHALL NOT BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES EXCEPT TO THE EXTENT PROVIDED (OR PROHIBITED) BY APPLICABLE LAW.
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES,
SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS,
AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
FOR THE NAME OF YOUR NEAREST AUTHORIZED NILES DEALER CONTACT:
NILES AUDIO CORPORATION, P.O. BOX 160818, MIAMI, FLORIDA 33116-0818
OR VISIT US AT WWW.NILESAUDIO.COM
Please fill in your product information and retain for your records.
Model______________________ Serial No.___________________ Purchase Date________
28
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY REGISTRATION CARD
Model Purchased_________________________________________________________
Serial Number ___________________________________________________________
Date Purchased (month/day/year)_____________________________________________
Dealer Name and Location __________________________________________________
______________________________________________________________________
❍
❍
❍
❍
❍
Dr.
Miss
Mr.
Mrs.
Ms.
Name__________________________________________________________________
Address________________________________________________________________
______________________________________________________________________
City_______________________________________State________________Zip______
Telephone (
) _________________________________________________
Please take a moment to fill out our warranty registration card. The information helps us to get to
know you better and develop the products you want
Age:
Musical tastes:
(Please check
all that apply)
What magazines
do you read?
Do you . . . ?
❍
❍
Under 25
Own a House. If yes,
❍
❍
❍
❍
25-34
1. ________________
how many square feet?
❍
35-44
Alternative
2. ________________
3. ________________
❍
45-54
55 & over
Classical
❍
Country
❍
Own a Town House/
❍
Jazz
Condominium/Co-op
Income:
❍
New Age
❍
Rent an Apartment
Rent a House
Who will install
the product?
❍
Under $24,999
❍
Popular
❍
❍
❍
❍
❍
❍
❍
$25,000-$34,999
$35,000-$44,999
$45,000-$59,999
$60,000-$74,999
$75,000-$99,999
Over $99,999
❍
R&B
❍
Custom Installer
❍
Rock
Are you interested in
receiving literature on
other Niles products?
❍
Electrician
❍
Other _____________
❍
Friend
Myself
❍
How did you hear
about Niles?
❍
❍
Yes
No
Which factor(s) influenced
the purchase of your Niles
product? (Please check
all that apply)
❍
Architect/Developer
Are there products/
capabilities that you would
like to see introduced?
❍
Occupation:
Custom Installer
❍
❍
Arts/Entertainment
Direct Mail
❍
❍
Business Owner
Friend/Family
❍
Ease of Use
❍
❍
Engineer
In-Store Display
❍
Price/Value
❍
❍
Finance/Accounting
Interior Designer
❍
Product Features
❍
❍
General Office
Magazine Ad
❍
Quality/Durability
❍
❍
Management
Mail-Order Catalog
❍
Reputation
❍
❍
Professional
Newspaper Ad
❍
Style/Appearance
❍
❍
Sales/Marketing
Product Brochure
❍
Warranty
❍
❍
Student
Product Review
❍
❍
Tradesperson
Retail Salesperson
29
Download from Www.Somanuals.com. All Manuals Search And Download.
®
BL E N D I N G HI G H FI D E L I T Y AN D AR C H I T E C T U R E
N i l e s A u d i o C o r p o r a t i o n
1 2 3 3 1 S . W . 1 3 0 S t r e e t M i a m i , F l o r i d a 3 3 1 8 6
1 - 3 0 5 - 2 3 8 - 4 3 7 3
1 - 8 0 0 - B U Y - H I F I
–
w w w . n i l e s a u d i o . c o m
©2007 Niles Audio Corporation. All rights reserved. Niles, the Niles logos and
Blending High Fidelity and Architecture are registered trademarks of Niles Audio Corporation.
All other trademarks are the property of their respective owners. DS00588A
Download from Www.Somanuals.com. All Manuals Search And Download.
|