Napoleon Fireplaces Outdoor Fireplace N415 0232 User Manual

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.  
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.  
INSTALLATION AND  
OPERATING INSTRUCTIONS  
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CR97-003, CAN1-2.21-M85, IAS U.S. 4-96.  
PATIOFLAME  
OUTDOOR GAS FIREPLACE  
GPFGN  
NATURAL GAS  
GPFGP  
PROPANE  
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.  
SAFETY INFORMATION  
WARNING!  
!
If the informaꢀon in these instrucꢀons are  
not followed exactly, a fire or explosion may  
result causing property damage, personal  
injury or loss of life.  
Do not store or use gasoline or other  
flammable vapors and liquids in the vicinity  
of this or any other appliance.  
WHAT TO DO IF YOU SMELL GAS:  
Do not try to light any appliance.  
Do not touch any electrical switch; do not  
use any phone in your building.  
Immediately call your gas supplier from  
a
neighbour’s phone. Follow the gas  
supplier’s instrucꢁons.  
If you cannot reach your gas supplier, call  
the fire department.  
APPLY SERIAL NUMBER LABEL FROM CARTON  
Installaꢀon and service must be performed  
by a qualified installer, service agency or  
the supplier.  
Serial No.  
XXXXXX000000  
MODEL NO.  
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /  
103 Miller Drive, Criꢀenden, Kentucky, USA, 41030  
N415-0232 AUG 18/10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
WARNING! For Outdoor Use Only.  
WARNING! Improper installaꢀon, adjustment, alteraꢀon, service or maintenance can  
cause injury or property damage. Read the installaꢀon, operaꢀng and maintenance  
instrucꢀons thoroughly before installing or servicing this gas paꢀo flame.  
SAFE OPERATING PRACTICES  
THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.  
Installaꢁon and repair should be done by a qualified service person. The appliance should be inspected  
before use and at least annually by a qualified service person. More frequent cleaning may be required as  
necessary. It is imperaꢁve the control compartment, burners and circulaꢁng air passageways of the appliance  
be kept clean.  
Do not operate appliance before reading and understanding operaꢁng instrucꢁons. Failure to operate  
appliance according to operaꢁng instrucꢁons could cause fire or injury.  
Risk of burns. The appliance should be turned off and cooled before servicing.  
Do not install damaged, incomplete or subsꢁtute components.  
Young children should be carefully supervised when they are in the vicinity of the appliance. Toddlers,  
young children and others may be suscepꢁble to accidental contact burns. A physical barrier is recommended  
if there are at risk individuals in the house. To restrict access to an appliance or stove, install an adjustable  
safety gate to keep toddlers, young children and other at risk individuals out of the vicinity and away from  
hot surfaces.  
Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot  
surfaces.  
Under no circumstances should this appliance be modified.  
Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with  
all plasꢁc bags, these are not toys and should be kept away from children and infants.  
Do not leave appliance unaꢀended when in use.  
For Outdoor use only.  
This appliance must not be used for cooking.  
This unit is not for use with solid fuel.  
Improper installaꢁon, adjustment, alteraꢁon, service, or maintenance can cause injury or property damage.  
Read the installaꢁon, operaꢁng and maintenance instrucꢁons thoroughly before installing or servicing this  
equipment.  
This appliance shall be used ONLY outdoors in a well-venꢁlated space and shall NOT be used inside a building,  
garage, or any other enclosed area.  
Cylinders must be stored outdoors in a well-venꢁlated area out of reach of children. Disconnected cylinders  
must have threaded valve plugs ꢁghtly installed and must not be stored in a building, garage or any other  
enclosed area.  
Storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply (natural  
gas line or LP gas cylinder).  
If it is evident there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the appliance  
being put into operaꢁon.  
Clothing or other flammable materials should not be hung from the appliance, or placed on or near the  
appliance.  
Any guard or other protecꢁve device removed for servicing the appliance must be replaced prior to operaꢁng  
the appliance.  
Inspect the fuel supply connecꢁon for signs of leakage (including the hose for LP models) before each use  
of the appliance.  
The pressure regulator and hose assembly supplied with LP models must be used. Replacement pressure  
regulators and hose assemblies must be those specified in this manual.  
The LP gas supply cylinder used with LP models must be constructed and marked in accordance with the  
specificaꢁons for LP-gas cylinders as required by the U.S. Department of Transportaꢁon (DOT) or the Canadian  
Transport Commission (CTC).  
The LP gas cylinder supply system must be arranged for vapour withdrawal.  
The LP-gas cylinder used must include a collar to protect the cylinder valve.  
When an LP model is not in use, the LP-gas must be turned off at the supply cylinder.  
To extend the life of your appliance, protect and cover it from the elements when not in use.  
This product must be installed by a licensed plumber or gas fiꢀer when installed within the commonwealth  
of Massachuseꢀs.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
GENERAL INFORMATION  
This appliance should be installed and serviced by a qualified installer to conform with local codes.  
Installaꢁon pracꢁces vary from region to region and it is important to know the specifics that apply to your  
area, for example: in Massachuseꢀs State:  
The appliance off valve must be a “T” handle gas cock.  
The flexible connector must not be longer than 36 inches.  
The installaꢁon must conform with local codes or in the absence of local codes, with the Naꢁonal Fuel Gas  
Code ANSI Z223.1/INFPA 54 in the United States or CSA B149.1, Natural and Propane Installaꢁon code in  
Canada.  
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during  
any pressure tesꢁng of the system at test pressures in excess of 1/2 psig (3.5kPa).  
This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve  
during any pressure tesꢁng of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa).  
The following clearances to combusꢀble materials must be maintained:  
Sides (all around)  
Top  
- 24 inches (610mm)  
- 72 inches (1.830m)  
Always keep the appliance area clear and free from combusꢁble materials, gasoline, and other flammable  
vapours and liquids.  
Do not locate appliance where it can get excessively  
wet.  
Do not use this appliance if any part has been  
under water. Immediately call a qualified service  
technician to inspect the unit and to replace any  
part of the control system and any gas control  
which has been underwater.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
SPECIFICATIONS  
DIMENSIONS  
INPUT  
GAS INLET PRESSURES  
NATURAL  
MODEL  
GPFN  
GPFP  
FUEL  
MAX. INPUT Btu/Hr  
60, 000  
PROPANE  
11.0" w.c.  
14.0" w.c.  
Natural Gas  
Propane Gas  
Minimum Inlet Pressure  
Maximum Inlet Pressure  
4.5" w.c.  
60, 000  
14.0" w.c.  
MINIMUM CLEARANCE TO COMBUSTIBLES  
INCHES  
24  
MM  
610  
Side Walls  
Top of unit to ceiling  
72  
1830  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
INSTALLATION  
WARNING! When the appliance is being used with the opꢀonal tripod, it must not be situated on a  
combusꢀble surface, nor can it be located below a combusꢀble overhang.  
The glass embers and the burner assembly are shipped together.  
Remove the glass embers and burner assembly and check for damage. DO NOT install damaged components.  
The glass embers may have sharp edges, wear safety glasses and gloves when handling.  
Place the appliance on a level/secure surface in desired locaꢁon. This locaꢁon must be adjacent to the  
gas supply line or cylinder.  
NOTE: Minimum clearances to combusꢀble construcꢀon must be maintained, see "SPECIFICATIONS" secꢀon.  
WARNING! You must have clear and easy access to the on/off valve AFTER the appliance is installed  
and connected to the gas supply in order to safely turn off the burner.  
THE ON/OFF GAS VALVE IS USED TO TURN THE BURNER ON AND OFF.  
NATURAL GAS  
Connect the incoming gas supply line to the on/off gas valve of the appliance. Make certain ALL gas connecꢁons are  
ꢁght, turn the on/off valve at the unit slowly to the on posiꢁon and use soapy water to test for leaks as indicated in  
the diagrams.  
DO NOT USE AN OPEN FLAME.  
Burner Assembly  
Manual Gas  
Valve (on/off)  
LP (PROPANE) GAS  
Aꢁach cylinder retaining bracket supplied to the base of the cylinder. Then secure to the surface to which it  
sits. Cylinder should be on a level surface.  
This appliance has been designed for use with a 20lb. (9.1kg) or a 30lb (13.6kg) size propane cylinder only  
(not supplied).  
Make sure cylinder valve is in its full off posiꢁon. (Turn clockwise to stop).  
Check cylinder valve features to ensure it has proper external maꢁng threads. (Cylinder Valve Marked:  
USE WITH TYPE 1)  
Inspect hose shipped with the unit for damage. Never aꢀempt to use damaged or plugged equipment. See  
your local LP Gas Dealer for repairs.  
Aſter inspecꢁng the LP hose shipped with the unit, connect the end with the female fiꢂng on the hose to  
the male fiꢂng on the on/off gas valve at the end of the flex tube. Tighten fiꢂngs using 2 wrenches.  
When connecꢁng regulator assembly to the cylinder valve, hand ꢁghten black QCC1 nut clockwise to a  
posiꢁve stop. DO NOT use a wrench to ꢁghten. Use of a wrench may damage the quick closing coupling  
nut and result in a hazardous condiꢁon.  
Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject  
to accidental damage.  
Open cylinder valve fully (counter-clockwise). Turn the on/off valve at the unit slowly to the on posiꢁon  
and use a soapy water soluꢁon to check all connecꢁons for leaks as indicated in the diagrams before  
aꢀempꢁng to light the appliance. If a leak is found, turn tank valve off and do not use the appliance unꢁl  
repairs can be made.  
DO NOT USE AN OPEN FLAME.  
Burner Assembly  
Manual Gas  
Valve (on/off)  
Cylinder Retaining  
Bracket  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
ENCLOSURES FOR LP GAS SUPPLY SYSTEMS  
WARNING! During the iniꢀal purging and subsequent lighꢀngs, NEVER allow gas valve to remain in  
the “Open” posiꢀon without first placing and igniꢀng the firestarter.  
If you build an enclosure for an LP gas cylinder, follow these recommended specificaꢀons. You must also  
follow local codes.  
Enclosures for LP gas supply cylinders shall be venꢁlated by openings at the level of the cylinder valve and  
at floor level. The effecꢁveness of the opening(s) for purposes of venꢁlaꢁon shall be determined with the  
LP gas supply cylinder(s) in place. This shall be accomplished by one of the following:  
One side of the enclosure shall be completely open;  
OR  
For an enclosure having four sides, a top and boꢁom:  
a) At least two venꢁlaꢁon openings at cylinder valve level shall be provided in the side wall, equally sized,  
spaced at 180 degrees (3.14 rad), and unobstructed. Each opening shall have a total free area of not less than  
½ square inch per pound (3.2 sq. cm/kg) of stored fuel capacity and not less than a total free area of 10 square  
inches (64.5 sq. cm).  
b) Venꢁlaꢁon opening(s) shall be provided at floor level and shall have a total free area of not less than ½ inch  
per pound (3.2 sq. cm/kg) of stored fuel capacity and not less than a total free area of 10 square inches  
(64.5 sq. cm). If venꢁlaꢁon openings at floor level are in a side wall, there shall be at least two openings. The  
boꢀom of the openings shall be at floor level and the upper edge no more than 5 inches (127mm) above the  
floor. The openings shall be equally sized, spaced at 180 degrees (3.14 rad) and unobstructed.  
c) Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 inch (3.2mm) diameter  
rod.  
Cylinder valves shall be readily accessible for hand operaꢁon. A door on the enclosure to gain access to  
the cylinder valve is acceptable, provided it is  
QCC1  
non-locking and can be opened without the  
use of tools.  
There shall be a minimum clearance of 2 inches  
(50.8mm) between the lower surface of the  
floor of the LP gas supply cylinder enclosure  
and the ground.  
Propane Regulator  
Hose  
Manual Gas  
Valve (on/off)  
Natural Gas  
Supply Line  
(not supplied)  
The design of the enclosure shall be such  
that (1) the LP gas supply cylinder(s) can be  
connected, disconnected and the connecꢁons  
Cylinder Retaining  
Bracket  
inspected and tested outside the cylinder enclosure; and (2) those connecꢁons which could be disturbed  
when installing the cylinder(s) in the enclosure can be leak tested inside the enclosure.  
Be certain to mount or set the LP gas cylinder on a flat surface and restrain it to prevent it from ꢁpping.  
Purge the gas supply line of any trapped air prior to the first firing of the unit.  
CYLINDER RETAINING BRACKET  
1. Fasten the bracket to the boꢀom of the propane boꢀle using bolt  
and nut supplied.  
2. Tighten the lag screw into the mounꢁng surface leaving  
approximately 1/4” of thread above the surface.  
3. Slide propane boꢀle into posiꢁon so that the bracket slides under  
the head of the lag screw.  
4. Tighten the lag screw onto the bracket.  
5. For fastening to a concrete surface a concrete anchor will be required.  
(Not supplied)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
FINISHING  
GLASS MEDIA INSTALLATION  
WARNING! Glass embers may have sharp edges, wear safety glasses and gloves when handling.  
Do not change or subsꢀtute the glass ember material provided with this fireplace. If replacing, use only  
replacement glass embers available from your local authorized dealer / distributor.  
WARNING! Glass embers may have a fine oil residue that needs to be cleaned prior to installaꢀon.  
Clean the glass with mild dish soap, drain, rinse thoroughly and dry before installing  
1. Carefully pour the appliance glass media onto the appliance log support as shown.  
2. Spread the glass evenly over the pan burner. The distribuꢁon of clear glass over the burner pan will influence  
flame height.  
OPTIONAL MKR ROCK INSTALLATION  
WARNING! Real rocks must not be used in this appliance. Heat will cause them to explode.  
1. Remove the glass media from your appliance.  
2. Place the 4 notched rocks and 2 clusters on the edge of the burner pan as shown, making sure not to cover any ports.  
3. Place the remaining refractory rocks on and around the burner as desired. (There are not set locaꢁons).  
4. Spread the lava rock removed in Step 1 and evenly distribute it around the rocks.  
Notched  
Rock  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
OPERATION  
WARNING! If you do not follow these instrucꢀons exactly a fire or explosion may result causing property  
damage, personal injury or loss of life.  
Upon compleꢁng the gas line connecꢁon, a small amount of air will be in the lines. When first lighꢁng the  
burner, it will take a few seconds for the lines to purge themselves of this air.  
Once the purging is complete, the burner will light and operate as indicated in the instrucꢁon manual. Subsequent  
lighꢁng of the appliance will not require such pruging unless the gas supply has been disconnected.  
FOR YOUR SAFETY READ BEFORE LIGHTING:  
A. This appliance must be lit by hand while following these instrucꢁons exactly.  
B. Before operaꢁng smell all around the appliance area for gas and next to the floor because some gas is  
heavier than air and will seꢀle on the floor.  
C. Use only your hand to turn the manual gas control valve. Never use tools. If the valve will not turn by hand,  
do not try to repair it. Call a qualified service technician. Force or aꢀempted repair may result in a fire or  
explosion.  
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to  
inspect the appliance and replace any part of the control system and any gas control which has been underwater.  
WHAT TO DO IF YOU SMELL GAS:  
Do not try to light any appliance.  
Do not touch any electric switch; Do not use any phone in your building.  
Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instrucꢁons.  
If you cannot reach your gas supplier, call the fire department.  
LIGHTING INSTRUCTIONS:  
1. Locate the manual gas control valve.  
2. Place the firestarter near the burner ports on top of the burner. Light the firestarter. For a Natural Gas unit,  
turn on the ON/OFF valve slowly at the unit. For a LP unit, turn the valve in the LP tank counter clockwise all  
the way and then turn on the ON/OFF valve slowly at the unit.  
3. If the burner does not light before the fire starter goes out, immediately turn the gas off.  
4. Wait at least five (5) minutes to clear out any gas. Then smell for gas including near the base of the unit. If you  
smell gas, STOP! Refer to the safety informaꢁon in the owner’s manual. If you don’t smell gas, repeat step 2.  
TO TURN OFF GAS:  
Turn the ON/OFF valve to the off posiꢁon at the unit for Natural Gas unit.  
For LP unit, turn the ON/Off valve to the off posꢁon at the unit and then turn the valve on the LP tank to the  
OFF posiꢁon clockwise.  
Note: The propane regulator in this appliance is equipped with a low flow protecꢁon device. Unless the  
propane cylinder valve is opened before the appliance valve, the gas flow will be reduced resulꢁng in a very  
small flame. To reset this device, shut off the appliance valve, then the propane cylinder valve. Next, diconnect  
the regulator adaptor from the tank and then reconnect. Follow the lighꢁng procedure ensuring the propane  
cylinder valve is opened before the unit is.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
MAINTENANCE  
The appliance should be inspected before iniꢁal use and  
inspected and cleaned at least annually by a qualified field  
service person.  
Tampering is DANGEROUS and voids all warranꢁes. Any  
component that is found to be faulty, must be replaced with  
an approved component.  
To obtain proper operaꢁon, it is imperaꢁve that the burner  
flame characterisꢁcs are steady, not liſting or floaꢁng. Check  
the burner flame paꢀerns with the image.  
Periodically remove the glass embers and examine the burner.  
If dirty, clean with a soſt brush. Also examine the area  
around the burner air shuꢀer. Any dirt or foreign material,  
such as spider webs or nests, in this area should be removed.  
This will ensure long life and trouble free operaꢁon. When the appliance is put back in service, check the  
burner flame paꢀerns with the image. Reinstall the glass embers as shown in the glass media installaꢁon.  
Periodically check the hose connecꢁng the LP gas cylinder to ensure it is not damaged in any way.  
During the winter months in cold weather climates, it is recommended to disconnect the Paꢀoflame and  
store it in a cool dry place. Do not store the propane tank inside. For the remainder of the year, protect and  
cover your Paꢀoflame from rain, freezing rain and snow.  
HIGH ELEVATION INSTALLATION  
This listed gas appliance is tested and approved for elevaꢁons from 0 to 4500 feet in Canada and the U.S.  
When installing this appliance at an elevaꢁon above 4500 feet (in the U.S.), it may be necessary to decrease  
the input raꢁng by changing the exisꢁng burner orifice to a smaller size. Input should be reduced four percent  
(4%) for each 1,000 feet beyond the 4,500 feet above sea level, unless the heaꢁng value of the gas has been  
reduced, in which case this general rule will not apply. To idenꢁfy the proper orifice size, check with the local  
gas uꢁlity.  
When installing this unit at an elevaꢁon above 4,500 feet (in Canada), check with local authoriꢁes.  
Consult your local gas uꢁlity for assistance in determining the proper orifice for your locaꢁon.  
CLEANING STAINLESS STEEL  
Stainless steel tends to oxidize or stain in the presence of chlorides and sulfides, parꢁcularly in coastal areas  
and other harsh environments, such as the warm, highly humid atmosphere around pools and hot tubs. These  
stains could be perceived as rust, but can be easily removed or prevented. To provide stain prevenꢁon and  
removal, wash all stainless steel surfaces every 3-4 weeks or as oſten as required with fresh water and/or  
stainless steel cleaner.  
Cleaning The Stainless Steel Surface: Do not use abrasive cleaners or steel wool on the stainless steel parts.  
Doing so will scratch the finish. Surfaces should be cleaned with warm soapy water while the metal is sꢁll  
warm to the touch. To clean stainless surfaces, use a stainless steel or non-abrasive cleaner. Always wipe in  
the direcꢁon of the grain. Over ꢁme, stainless steel parts discolour when heated, usually to a golden or brown  
hue. This discolouraꢁon is normal and does not affect the performance of the appliance.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
REPLACEMENTS  
Contact your dealer or the factory for quesꢁons concerning prices and policies on replacement parts. Normally  
all parts can be ordered through your Authorized dealer / distributor.  
FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO  
HONOUR THE CLAIM.  
When ordering replacement parts always give the following informaꢀon:  
Model & Serial Number of appliance  
Installaꢁon date of appliance  
Part number  
Descripꢁon of part  
Finish  
* IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR FURTHER INFORMATION, CONTACT YOUR AUTHORIZED  
DEALER.  
WARNING! Failure to posiꢀon the parts in accordance with this manual or failure to use only parts  
specifically approved with this appliance may result in property damage or personal injury.  
COMPONENTS  
DESCRIPTION  
REF PART NO.  
1
2
3
4
5
QA-047  
OUTER BASE  
LOG SUPPORT  
BURNER ASSEMBLY  
ORIFICE BRACKET  
PROPANE ORIFICE - #43  
NATURAL GAS ORIFICE - #25  
#60 ORIFICE, “blank” (NG)  
#60 ORIFICE, “blank” (LP)  
GLASS EMBERS - BRONZE  
FLEX c/w SHUT OFF - STAINLESS STEEL  
PROPANE REGULATOR / HOSE ASSEMBLY (LP UNITS ONLY)  
NG REGULATOR (NG UNITS ONLY)  
ACCESSORIES  
W655-0176  
W010-1030  
W080-0618  
W455-0076  
W455-0077  
W455-0079  
W455-0080  
N300-0002  
W175-0210  
W530-0023  
W530-0024  
6
7
8
9
REF PART NO.  
DESCRIPTION  
10 W320-0014  
WIRE GUARD  
*
*
*
*
N345-0001  
PFS  
PFT  
NATURAL GAS HOSE 10FT  
SAFETY SCREEN  
PATIO FLAME TABLE  
PFTT-GK  
GRANITE TABLE TOP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
3
10  
4
8
5
9
7
6
2
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
SERVICE HISTORY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Multiquip Automobile Parts HHXD5 User Manual
Niles Audio Portable Speaker OS3 User Manual
Nostalgia Electrics Frozen Dessert Maker ICM 562 User Manual
Omega Blender BL600 User Manual
Onkyo Stereo Receiver TXNR828 User Manual
Onkyo Stereo System TX 8211 User Manual
Oster Bread Maker CKSTBRTW20 User Manual
Panamax Surge Protector M2 av User Manual
Panasonic CD Player CQ DFX202N User Manual
Panasonic Pedicure Spa EP30102 User Manual