INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.  
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CR97-003, CAN1-2.21-M85, IAS U.S. 4-96.  
PATIOFLAME  
INSTALLATION AND OPERATION INSTRUCTIONS FOR  
OUTDOOR GAS FIREPLACE  
NATURAL GAS MODEL GPFN  
PROPANE GAS MODEL GPFP  
WARNING: If the information in these instructions is not followed exactly, a fire or  
explosion may result causing property damage, personal injury or death.  
FOR YOUR SAFETY  
Do not store or use gasoline or other flammable vapours and liquids in the vicinity  
of this or any other appliance.  
WHAT TO DO IF YOU SMELL GAS:  
• Do not try to light any appliance.  
• Do not touch any electrical switch.  
• Do not use any phone in your build  
ing.  
Immediately call your gas supplier  
from a neighbour's phone. Follow the  
gas supplier's instructions.  
• If you cannot reach your gas supplier,  
call the fire department.  
Installation and service must be performed by a qualified installer, service agency  
or the gas supplier.  
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031  
W415-0372 / 02.12.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
NAPOLEON gas appliances are manufactured under the strict Standard of the world recognized  
ISO 9001 : 2000 Quality Assurance Certificate.  
NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who  
take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station. Once  
assembled the complete appliance is thoroughly inspected by a qualified technician before packaging to ensure that  
you, the customer, receives the quality product that you expect from NAPOLEON.  
NAPOLEON warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears on the  
W415-0372 / 02.12.03  
4
GENERAL INFORMATION  
• Ins ta lla tion a nd re pa ir s hould be done by a qua li-  
WARNING  
fie d s e rvic e pe rs on. The a pplia nc e s hould be in-  
spected before use and at least annually by a quali-  
fie d s e rvic e pe rs on. More fre que nt c le a ning ma y  
be re quire d a s ne c e s s a ry. It is impe rative the c on-  
trol compartment, burners and circulating air pas-  
s a ge wa ys of the a pplia nc e be ke pt c le a n.  
This appliance shall be used ONLY outdoors in a  
well- ventilated space and shall NOT be used inside  
a building, garage, or any other enclosed area.  
WARNING  
This appliance MUST NOT be used for cooking.  
• If it is evident there is excessive abrasion or wear ,  
or the hos e is c ut, it mus t be re pla c e d prior to the  
a pplia nc e be ing put into ope ra tion.  
WARNING  
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.  
• Childre n a nd a dults s hould be a le rte d to the ha z-  
ards of high surface temperatures and should stay  
a wa y to a void burns or c lothing ignition.  
WARNING  
Cylinders must be stored outdoors in a well-  
ventilated area out of reach of children. Discon-  
nected cylinders must have threaded valve plugs  
tightly installed and must not be stored in a  
building, garage or any other enclosed area.  
Young childre n s hould be c a re fully s upe rvis e d  
whe n they a re in the a re a of the applia nc e.  
• Clothing or other flammable materials s hould not  
be hung from the a pplia nc e , or pla c e d on or ne a r  
the applia nc e.  
WARNING  
Storage of this appliance indoors is permissible  
only if it has been disconnected from its fuel  
supply (natural gas line or LP gas cylinder).  
• Any gua rd or othe r prote c tive de vic e re move d  
for s ervicing the appliance mus t be replaced prior  
to ope rating the applia nc e.  
• Ins pe c t the fue l s upply c onne c tion for s igns of  
le a ka ge (inc luding the hos e for LP mode ls ) be fore  
e a ch us e of the a pplia nc e.  
The installation must conform with Local codes or in  
the absence of local codes, with the National Fuel Gas  
Code ANSI Z223.1/INFPA 54 in the United States or  
CSA B149.1, Natural and Propane Installation code in  
Canada.  
• The pre s s ure re gula tor a nd hos e a s s e mbly s up-  
plie d with LP mode ls mus t be us e d. Re pla c e me nt  
pres s ure regulators and hos e as s emblies mus t be  
thos e s pe c ifie d in this ma nua l.  
• The LP ga s s upply c ylinde r us e d with LP mode ls  
mus t be c ons truc te d a nd ma rke d in a c c orda nc e  
with the s pe c ific a tions for LP-ga s c ylinde rs a s re -  
quire d by the U.S. Depa rtme nt of Tra ns portation  
(DOT) or the Ca na dia n Tra ns port Commis s ion  
(CTC).  
The appliance and its individual shut off valve must be  
disconnected from the gas supply piping system during  
any pressure testing of the system at test pressures in  
excess of 1/2 psig (3.5kPa).  
This appliance must be isolated from the gas supply  
piping system by closing its individual manual shut off  
valve during any pressure testing of the gas supply pip-  
ing system at test pressures equal to or less than 1/2  
psig (3.5kPa).  
• The LP ga s c ylinde r s upply s ys te m mus t be a r-  
ra nge d for vapour withdraws.  
• The LP-ga s c ylinde r us e d mus t inc lude a c olla r  
to prote c t the cylinde r va lve.  
The following clearances to combustible materials must  
be maintained: Bottom - 0 inches, Sides (all around) -  
24 inches (610mm), Top - 6 feet (1.830m).  
• Whe n a n LP mode l is not in us e , the LP-ga s mus t  
be turne d off at the s upply cylinde r.  
Always keep the appliance area clear and free from  
combustible materials, gasoline, and other flammable  
vapours and liquids.  
• To exte nd the life of your Patiofla me, prote c t a nd  
c ove r it from the e le me nts whe n not in us e.  
Do not locate appliance where it can get excessively  
wet. Do not use this appliance if any part has been  
under water. Immediately call a qualified service techni-  
cian to inspect the unit and to replace any part of the  
control system and any gas control which has been  
underwater.  
W415-0372 / 02.12.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
SPECIFICATIONS  
DIMENSIONS  
INPUT  
Model  
Fuel  
Max. Input  
Btu/Hr  
GPFN  
GPFP  
Natural Gas  
60,000  
Propane Gas  
60,000  
GAS INLET PRESSURES  
Natural  
LP (Propane)  
Minimum Inlet Pressure  
4.5" w.c.  
11.0" w.c.  
14.0"w.c.  
Maximum Inlet Pressure 14.0"w.c  
MINIMUM CLEARANCE TO COMBUSTIBLES  
Inches  
mm  
Floor  
0
0
Side Walls  
24  
72  
610  
1830  
Top of unit to ceiling  
W415-0372 / 02.12.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
INSTALLATION  
The log set and the burner assembly are shipped together.  
ENCLOSURES FOR LP GAS SUPPLY SYSTEMS  
If you build an enclosure for an LP gas cylinder, follow  
these recommended specifications. You must also follow  
local codes.  
Enclosures for LP gas supply cylinders shall be ventilated  
by openings at the level of the cylinder valve and at floor  
level. The effectiveness of the opening(s) for purposes of  
ventilation shall be determined with the LP gas supply  
cylinder(s) in place. This shall be accomplished by one of  
the following:  
Remove the gas log set and burner assembly and check  
for damage. DO NOT install damaged components. The  
logs are fragile use care when handling.  
Place the Patioflame on a level/secure surface in desired  
location. This location must be adjacent to the gas supply  
cylinder.  
NOTE:Minimum clearances to combustible construction  
must be maintained. ( See Page 5)  
You must have clear and easy access to the on/off valve  
AFTER the appliance is installed and connected to the gas  
supply in order to safely turn off the burner.  
1. One side of the enclosure shall be completely open;  
or  
THE ON/OFF GAS VALVE IS USED TO TURN THE  
BURNER ON AND OFF.  
2. For an enclosure having four sides, a top and bottom:  
a) At least two ventilation openings at cylinder valve level  
shall be provided in the side wall, equally sized, spaced at  
180 degrees (3.14 rad), and unobstructed. Each opening  
shall have a total free area of not less than ½ square inch  
per pound (3.2 sq. cm/kg) of stored fuel capacity and not  
less than a total free area of 10 square inches (64.5 sq. cm).  
b) Ventilation opening(s) shall be provided at floor level  
and shall have a total free area of not less than ½ inch per  
pound (3.2 sq. cm/kg) of stored fuel capacity and not less  
than a total free area of 10 square inches (64.5 sq. cm). If  
ventilation openings at floor level are in a side wall, there  
shall be at least two openings. The bottom of the openings  
shall be at floor level and the upper edge no more than 5  
inches (127mm) above the floor. The openings shall be  
equally sized, spaced at 180 degrees (3.14 rad) and unob-  
structed.  
c) Every opening shall have minimum dimensions so as  
to permit the entrance of a 1/8 inch (3.2mm) diameter rod.  
3. Cylinder valves shall be readily accessible for hand op-  
eration. A door on the enclosure to gain access to the cylin-  
der valve is acceptable, provided it is non-locking and can  
be opened without the use of tools.  
4. There shall be a minimum clearance of 2 inches  
(50.8mm) between the lower surface of the floor of the LP  
gas supply cylinder enclosure and the ground.  
NATURAL GAS  
Connect the incoming gas supply line to the on/off gas  
valve of the appliance. Make certain ALL gas connections  
are tight, turn the on/off valve at the unit slowly to the on  
position and use soap water to test for leaks.  
DO NOT USEAN OPEN FLAME.  
LP GAS  
1. Place the cylinder in the ring on the base. Base should  
be on level surface.  
2. Make sure tank valve is in its full off position. (Turn clock-  
wise to stop).  
3. Check tank valve features to ensure it has proper exter-  
nal mating threads. (Tank Valve Marked: USE WITH TYPE  
1)  
4. Inspect hose shipped with the unit for damage. Never  
attempt to use damaged or plugged equipment. See your  
local LP Gas Dealer for repairs.  
5. After inspecting the LP hose shipped with the unit, con-  
nect the end with the female fitting on the hose to the male  
fitting on the on/off gas valve at the end of the flex tube.  
Tighten fittings using 2 wrenches.  
6. When connecting regulator assembly to the tank valve,  
hand tighten black QCC1 nut clockwise to a positive stop.  
DO NOT use a wrench to tighten. Use of a wrench may  
damage the quick closing coupling nut and result in a haz-  
ardous condition.  
7. Locate the hose out of pathways where people may trip  
over it or in areas where the hose may be subject to acci-  
dental damage.  
5. The design of the enclosure shall be such that (1) the LP  
gas supply cylinder(s) can be connected, disconnected  
and the connections inspected and tested outside the cyl-  
inder enclosure; and (2) those connections which could  
be disturbed when installing the cylinder(s) in the enclo-  
sure can be leak tested inside the enclosure.  
6. Be certain to mount or set the LP gas cylinder on a flat  
surface and restrain it to prevent it from tipping.  
8. Open tank valve fully (counter-clockwise). Turn the on/off Purge the gas supply line of any trapped air prior to the first  
valve at the unit slowly to the on position and use a soapy firing of the unit.  
water solution to check all connections for leaks before WARNING: During the initial purging and subsequent  
attempting to light the appliance. If a leak is found, turn lightings, NEVER allow gas valve to remain in the "Open"  
tank valve off and do not use the appliance until repairs position without first placing and igniting the firestarter.  
can be made.  
W415-0372 / 02.12.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
1. Set base log onto burner ensuring stud and bracket fit  
into hole and notch. Base log should sit flat on "Patioflame"  
base.  
2. Place "Y" end of log #1 into "Y" notch on the base log.  
3. Place pocket on log #2 onto the locator on the base log.  
W415-0372 / 02.12.03  
8
OPERATION  
Upon completing the gas line connection, a small amount Once the purging is complete, the burner will light and  
of air will be in the lines. When first lighting the burner, it will operate as indicated in the instruction manual. Subsequent  
take a few seconds for the lines to purge themselves of lighting of the appliance will not require such purging un-  
this air.  
less the gas supply has been disconnected.  
WARNING: Read and follow the safety and lighting instructions page in this manual and on labels on the appliance. IF  
YOU DO NOT FOLLOW THESE INSTRUCTIONS PRECISELY, A FIRE OR EXPLOSION MAY RESULT AND YOU MAY BE  
SERIOUSLY INJURED.  
FOR YOUR SAFETY READ BEFORE LIGHTING:  
WHAT TO DO IF YOU SMELL GAS  
• Do not try to light any appliance.  
• Do not touch any electric switch; do  
not use any phone in your building.  
• Immediately call your gas supplier from a neighbour's  
phone. Follow the gas supplier's instructions.  
• If you cannot reach your gas supplier, call the fire de-  
partment.  
A. This appliance must be lit by hand while following  
these instructions exactly.  
B. Before operating smell all around the appliance area  
for gas and next to the floor because some gas is  
heavier than air and will settle on the floor  
C. Use only your hand to turn the manual gas control  
valve. Never use tools. If the valve will not turn by hand,  
do not try to repair it. Call a qualified service technician.  
Force or attempted repair may result in a fire or explo-  
sion.  
D. Do not use this appliance if any part has been under  
water. Immediately call a qualified service technician to  
inspect the appliance and replace any part of the control  
system and any gas control which has been under water.  
LIGHTING INSTRUCTIONS  
3. If the burner does not light before the match goes out,  
1. Locate the manual gas control valve.  
immediately turn the gas off.  
2. Place the firestarter near the burner ports on top of  
the burner. Light the firestarter. For a Natural Gas  
unit, turn on the ON/OFF valve slowly at the unit. For  
a LP unit, turn the valve in the LP tank counter clock-  
wise all the way and then turn on the ON/OFF valve  
slowly at the unit.  
4. Wait at least five (5) minutes to clear out any gas.  
Then smell for gas including near the base of the  
unit. If you smell gas, STOP! Refer to the safety infor-  
mation in the owner's manual. If you don't smell gas,  
repeat step 2.  
TO TURN OFF GAS  
Turn the ON/OFF valve to the off position at the unit for For LP unit, turn the ON/OFF valve to the off position at the  
Natural Gas unit.  
unit and then turn the valve on the LP tank to the OFF  
position clockwise.  
NOTE  
The propane regulator in this appliance is equipped  
with a low flow protection device. Unless the propane  
cylinder valve is opened before the patioflame valve,  
the gas flow will be reduced resulting in a very small  
flame.  
To reset this device, shut off the patioflame valve, then  
the propane cylinder valve.  
Next, disconnect the regulator adaptor from the tank  
and then reconnect. Follow the lighting procedure en-  
suring the propane cylinder valve is opened before the  
unit is.  
W415-0372 / 02.12.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
MAINTENANCE  
During the winter months in cold weather climates, it is  
1. The appliance should be inspected before initial use  
and inspected and cleaned at least annually by a qualified  
field service person.  
recommended to disconnect the Patioflame and store it in  
a cool dry place. Do not store the propane tank inside. For  
the remainder of the year, protect and cover your Patioflame  
from rain, freezing rain and snow.  
2. Tampering is DANGEROUS and voids all warranties.  
Any component that is found to be faulty, must be replaced  
with an approved component.  
HIGH ELEVATION INSTALLATION  
3. To obtain proper operation, it is imperative that the burner  
flame characteristics are steady, not lifting or floating. Check  
the burner flame patterns with the figure below.  
This listed gas appliance is tested and approved for eleva-  
tions from 0 to 4500 feet in Canada and the U.S.  
When installing this appliance at an elevation above 4500  
feet (in the U.S.), it may be necessary to decrease the input  
rating by changing the existing burner orifice to a smaller  
size. Input should be reduced four percent (4%) for each  
1,000 feet above sea level, unless the heating value of the  
gas has been reduced, in which case this general rule will  
not apply. To identify the proper orifice size, check with the  
local gas utility.  
When installing this unit at an elevation above 4,500 feet  
(in Canada), check with local authorities.  
Consult your local gas utility for assistance in determining  
the proper orifice for your location.  
4. Periodically remove the logs and examine the burner. If  
dirty, clean with a soft brush. Also examine the area around  
the burner air shutter. Any dirt or foreign material, such as  
spider webs or nests, in this area should be removed.  
This will ensure long life and trouble free operation. When  
the appliance is put back in service, check the burner flame  
patterns with the figure above. Reinstall the logs as shown  
in the log placement instructions.  
5. Periodically check the hose connecting the LP gas cylin-  
der to ensure it is not damaged in any way.  
NOTE: Carbon (soot) may build up on the surface of the  
logs with heavy use. This is more likely to occur when us-  
ing LP gas. The soot should be cleaned off the surface of  
the logs periodically to prevent excessive build up. To clean  
the logs, be sure the fire is out, the gas supply is turned off  
and the logs are cool to the touch. The soot can then be  
brushed off with a dry bristle brush or cloth. Take care while  
cleaning the logs as they can become damaged if mis-  
handled. Care should be taken to dispose of the soot and  
cleaning materials properly. Keep away from clothing and  
outdoor furniture.  
W415-0372 / 02.12.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
REPLACEMENTS  
Contact your Napoleon dealer or the factory for questions 1. MODEL & SERIAL NUMBER OF APPLIANCE  
concerning prices and policies on replacement parts. Nor-  
mally all parts can be ordered through your Napoleon dealer  
or distributor.  
2. INSTALLATION DATE OF APPLIANCE  
3. PART NUMBER  
4. DESCRIPTION OF PART  
5. FINISH  
When ordering replacement parts always give the follow-  
ing information:  
FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE  
ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.  
* IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR  
FURTHER INFORMATION, CONTACT YOUR NAPOLEON  
DEALER.  
REPLACEMENT PARTS  
1
2
3
8
9
9
W035-0104  
W655-0176  
W010-1030  
W080-0618  
W455-0076  
W455-0077  
OUTER BASE  
LOG SUPPORT  
BURNERASSEMBLY  
ORIFICE BRACKET  
PROPANE ORIFICE - #43  
NATURAL GAS ORIFICE - #25  
LOG SET  
10 GL-640  
11 W135-0189  
12 W135-0190  
13 W135-0191  
14 W135-0192  
15 W135-0193  
16* W550-0004  
17* W550-0004  
18 W175-0210  
19 W530-0023  
20 W655-0171  
21 W530-0024  
BASE LOG  
LOG #1  
LOG #2  
LOG #3  
LOG #4  
AGGREGATE SHALE  
AGGREGATE LAVAROCK  
FLEX c/w SHUT OFF - stainless steel  
PROPANE REGULATOR / HOSEASSEMBLY (LP UNITS ONLY)  
BASE (LP UNITS ONLY)  
NG REGULATOR (NG UNITS ONLY)  
W415-0372 / 02.12.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
W415-0372 / 02.12.03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wolf Steel Appliance Service History  
This appliance must be serviced annually depending on usage.  
Service Technician  
Name  
Date  
Dealer Name  
Service Performed  
Special Concerns  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Nextar Digital Photo Frame N7 107 User Manual
Nikon Network Card SNT V504 User Manual
Nintendo Video Games 64327A User Manual
Numark Industries Musical Instrument DXM 06 User Manual
Omega Marine Radio HHLM 1MV User Manual
Onkyo Portable CD Player CR 555 User Manual
Oster Mixer 131542 User Manual
Packard Bell Personal Computer M3350 User Manual
Palm Network Card ETHERNET HUB User Manual
Panasonic Car Stereo System CQ C7703N C7303N User Manual