OM-1582
138 593X
September 2001
Processes
MIG (GMAW)
Flux Cored (FCAW)
(Gas- and Self-Shielded)
Submerged (SAW)
Description
Wire Feeder
(Use with CV Power Sources)
D-64
Visit our website at
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols for Installation, Operation, and Maintenance . . . . . . . . . . . . . . . . . . . . . .
1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .
1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
3
3
4
5
5
5
WARNING
This product, when used
for welding or cutting,
produces fumes or
gases which contain
chemicals known to the
State of California to
cause birth defects and,
in some cases, cancer.
(California Health &
Safety Code Section
25249.5 et seq.)
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
8
8
1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 – DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Warning Label Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Rating Label For CE Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
9
10
10
SECTION 3 – INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SECTION 4 – INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4-1. Site Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Gun Recommendation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Equipment Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Rear Panel Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. 14-Pin Plug Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Wire Type, Size, And Feed Speed Capability Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Motor Start Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8. Rotating The Drive Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9. Installing And Threading Welding Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-10. Optional Equipment DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
12
12
13
13
14
14
15
16
17
SECTION 5 – OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5-1. Front Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Overload Protection And Optional Side Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18
19
SECTION 6 – MAINTENANCE AND TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
20
SECTION 7 – ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
SECTION 8 – PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
WARRANTY
OM-1582
Download from Www.Somanuals.com. All Manuals Search And Download.
Declaration of Conformity for
European Community (CE) Products
This information is provided for units with CE certification (see rating label on unit).
Note
Manufacturer’s Name:
Miller Electric Mfg. Co.
Manufacturer’s Address:
1635 W. Spencer Street
Appleton, WI 54914 USA
Declares that the product:
D-64
conforms to the following Directives and Standards:
Directives
Low Voltage Directive: 73/23/EEC
Electromagnetic Compatibility (EMC) Directive: 89/336/EEC
Machinery Directives: 89/392/EEC, 91/368/EEC, 93/C 133/04, 93/68/EEC
Standards
Arc Welding Equipment Part I: Welding Power Sources: IEC 60974-1
(September 1998 – Second Edition)
Arc Welding Equipment: Wirefeed Systems: IEC 974-5
(September 1997 – Draft Revision)
Degrees of Protection Provided By Enclosures (IP Code): IEC 529
(November 1989 – First Edition)
Insulation Coordination For Equipment With Low-Voltage Systems:
Part I: Principles, Requirements and Tests: IEC 664-1
(October 1992 – First Edition)
Electromagnetic Compatibility, (EMC): EN 50199
(August 1995)
European Contact:
Mr. Danilo Fedolfi, Managing Director
MILLER Europe S.r.l.
Via Privata Iseo
20098 San Giuliano
Milanese, Italy
Telephone:
Fax:
39(02)98290-1
39(02)98281-552
dec_con 11/96
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING
som _nd_4/98
1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.
Y
Marks a special safety message.
. Means “Note”; not safety related.
1-2. Arc Welding Hazards
Y
The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
the Safety Standards listed in Section 1-4. Read and follow all
Safety Standards.
D
D
D
If earth grounding of the workpiece is required, ground it directly
with a separate cable.
Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D
D
D
Wear a safety harness if working above floor level.
Keep all panels and covers securely in place.
Y
Y
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D
D
Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
ELECTRIC SHOCK can kill.
Do not connect more than one electrode or work cable to any
single weld output terminal.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
SIGNIFICANT DC VOLTAGE exists after removal of
input power on inverters.
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
groundedequipment is a hazard.
D
Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
D
D
D
Do not touch live electrical parts.
Wear dry, hole-free insulating gloves and body protection.
FUMES AND GASES can be hazardous.
Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
D
Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D
D
Keep your head out of the fumes. Do not breathe the fumes.
D
D
Use AC output ONLY if required for the welding process.
If inside, ventilate the area and/or use exhaust at the arc to remove
welding fumes and gases.
If AC output is required, use remote output control if present on
unit.
D
D
If ventilation is poor, use an approved air-supplied respirator.
D
Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
Read the Material Safety Data Sheets (MSDSs) and the
manufacturer’s instructions for metals, consumables, coatings,
cleaners, and degreasers.
D
D
Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D
Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watch-
person nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breath-
ing air is safe.
Always verify the supply ground – check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
groundedreceptacle outlet.
D
D
Do not weld in locations near degreasing, cleaning, or spraying op-
erations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D
D
When making input connections, attach proper grounding conduc-
tor first – double-check connections.
Frequently inspect input power cord for damage or bare wiring –
replace cord immediately if damaged – bare wiring can kill.
Do not weld on coated metals, such as galvanized, lead, or
cadmiumplated steel, unless the coating is removed from the weld
area, the area is well ventilated, and if necessary, while wearing an
air-suppliedrespirator. The coatings and any metals containing
these elements can give off toxic fumes if welded.
D
D
D
Turn off all equipment when not in use.
Do not use worn, damaged, undersized, or poorly spliced cables.
Do not drape cables over your body.
OM-1582 Page 1
Download from Www.Somanuals.com. All Manuals Search And Download.
ARC RAYS can burn eyes and skin.
BUILDUP OF GAS can injure or kill.
D
D
Shut off shielding gas supply when not in use.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
Always ventilate confined spaces or use
approved air-supplied respirator.
D
Wear a welding helmet fitted with a proper shade of filter to protect
your face and eyes when welding or watching (see ANSI Z49.1
and Z87.1 listed in Safety Standards).
HOT PARTS can cause severe burns.
D
D
D
Wear approved safety glasses with side shields under your
helmet.
D
D
Do not touch hot parts bare handed.
Use protective screens or barriers to protect others from flash and
glare; warn others not to watch the arc.
Allow cooling period before working on gun or
torch.
Wear protective clothing made from durable, flame-resistant mate-
rial (leather and wool) and foot protection.
MAGNETIC FIELDS can affect pacemakers.
WELDING can cause fire or explosion.
D
D
Pacemaker wearers keep away.
Wearers should consult their doctor before
going near arc welding, gouging, or spot
welding operations.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
NOISE can damage hearing.
D
D
D
Protect yourself and others from flying sparks and hot metal.
Do not weld where flying sparks can strike flammable material.
Noise from some processes or equipment can
damagehearing.
Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D
Wear approved ear protection if noise level is
high.
D
Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D
D
Watch for fire, and keep a fire extinguisher nearby.
CYLINDERS can explode if damaged.
Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D
D
Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock and fire hazards.
D
D
Protect compressed gas cylinders from excessive heat, mechani-
cal shocks, slag, open flames, sparks, and arcs.
Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D
D
Do not use welder to thaw frozen pipes.
Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D
D
D
D
D
Keep cylinders away from any welding or other electrical circuits.
Never drape a welding torch over a gas cylinder.
D
D
Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
Never allow a welding electrode to touch any cylinder.
Never weld on a pressurized cylinder – explosion will result.
Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
Use only correct shielding gas cylinders, regulators, hoses, and fit-
tings designed for the specific application; maintain them and
associated parts in good condition.
FLYING METAL can injure eyes.
D
D
Turn face away from valve outlet when opening cylinder valve.
D
Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D
Read and follow instructions on compressed gas cylinders,
associated equipment, and CGA publication P-1 listed in Safety
Standards.
D
Wear approved safety glasses with side
shields even under your welding helmet.
OM-1582 Page 2
Download from Www.Somanuals.com. All Manuals Search And Download.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
MOVING PARTS can cause injury.
D
Do not install or place unit on, over, or near
combustiblesurfaces.
D
D
Keep away from moving parts such as fans.
Keep all doors, panels, covers, and guards
closed and securely in place.
D
Do not install unit near flammables.
D
Do not overload building wiring – be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING UNIT can cause injury.
H.F. RADIATION can cause interference.
D
D
D
Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D
High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communicationsequipment.
Use equipment of adequate capacity to lift and
support unit.
D
Have only qualified persons familiar with
electronic equipment perform this installation.
If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.
D
D
The user is responsible for having a qualified electrician prompt-
ly correct any interference problem resulting from the installa-
tion.
If notified by the FCC about interference, stop using the
equipmentat once.
OVERUSE can cause OVERHEATING
D
D
Allow cooling period; follow rated duty cycle.
D
D
Have the installation regularly checked and maintained.
Reduce current or reduce duty cycle before
starting to weld again.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
D
Do not block or filter airflow to unit.
STATIC (ESD) can damage PC boards.
D
D
Put on grounded wrist strap BEFORE handling
boards or parts.
ARC WELDING can cause interference.
Use proper static-proof bags and boxes to
store, move, or ship PC boards.
D
Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
MOVING PARTS can cause injury.
D
Be sure all equipment in the welding area is
electromagneticallycompatible.
D
D
Keep away from moving parts.
Keep away from pinch points such as drive
rolls.
D
D
D
D
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive elec-
tronic equipment.
WELDING WIRE can cause injury.
Be sure this welding machine is installed and grounded
according to this manual.
D
D
Do not press gun trigger until instructed to do
so.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
1-4. Principal Safety Standards
Safety in Welding and Cutting, ANSI Standard Z49.1, from American
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-
dent of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale
Boulevard, Rexdale, Ontario, Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face
Protection, ANSI Standard Z87.1, from American National Standards
Institute, 1430 Broadway, New York, NY 10018.
Recommended Safe Practices for the Preparation for Weldingand Cut-
ting of Containers That Have Held Hazardous Substances, American
Welding Society Standard AWS F4.1, from American Welding Society,
550 N.W. LeJeune Rd, Miami, FL 33126
NationalElectrical Code, NFPA Standard 70, from National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.
Cutting And Welding Processes, NFPA Standard 51B, from National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
OM-1582 Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
1-5. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
Welding current, as it flows through welding cables, will cause electro-
magnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: “The body of evidence, in the
committee’s judgment, has not demonstrated that exposure to power-
frequency electric and magnetic fields is a human-health hazard.”
However, studies are still going forth and evidence continues to be
examined.Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
4. Keep welding power source and cables as far away from opera-
tor as practical.
5. Connect work clamp to workpiece as close to the weld as possi-
ble.
About Pacemakers:
To reduce magnetic fields in the workplace, use the following
procedures:
Pacemaker wearers consult your doctor first. If cleared by your doctor,
then following the above procedures is recommended.
OM-1582 Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT
UTILISATION
som _nd_fre 4/98
1-1. Signification des symboles
SignifieMise en garde ! Soyez vigilant ! Cette procédure
présente des risques de danger ! Ceux-ci sont identifiés
par des symboles adjacents aux directives.
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des
Y
Identifie un message de sécurité particulier.
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles
et aux directives ci-dessous afin de connaître les mesures à prendre pour
éviter tout danger.
. Signifie NOTA ; n’est pas relatif à la sécurité.
1-2. Dangers relatifs au soudage à l’arc
Y
Les symboles présentés ci-après sont utilisés tout au long du
présent manuel pour attirer votre attention et identifier les risques
de danger. Lorsque vous voyez un symbole, soyez vigilant et
suivez les directives mentionnées afin d’éviter tout danger. Les
consignes de sécurité présentées ci-après ne font que résumer
l’information contenue dans les normes de sécurité énumérées
à la section 1-4. Veuillez lire et respecter toutes ces normes de
sécurité.
D
N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-le-
champ les pièces endommagées. Entretenir l’appareil conformément
à ce manuel.
D
D
D
Porter un harnais de sécurité quand on travaille en hauteur.
Maintenir solidement en place tous les panneaux et capots.
Fixer le câble de retour de façon à obtenir un bon contact métal-métal
avec la pièce à souder ou la table de travail, le plus près possible de la
soudure.
Y
Y
L’installation, l’utilisation, l’entretien et les réparations ne doi-
vent être confiés qu’à des personnes qualifiées.
Au cours de l’utilisation, tenir toute personne à l’écart et plus par-
ticulièrement les enfants.
D
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact
avec tout objet métallique.
UN CHOC ÉLECTRIQUE peut tuer.
Il y a DU COURANT CONTINU IMPORTANT dans les
convertisseurs après la suppression de l’alimenta-
tion électrique.
Un simple contact avec des pièces électriques peut
provoquer une électrocution ou des blessures graves.
L’électrode et le circuit de soudage sont sous tension
dès que l’appareil est sur ON. Le circuit d’entrée et les
circuits internes de l’appareil sont également sous
D
Arrêter les convertisseurs, débrancher le courant électrique, et dé-
charger les condensateurs d’alimentation selon les instructions
indiquées dans la partie entretien avant de toucher les pièces.
tension à ce moment-là. En soudage semi-automatique ou automatique,
le fil, le dévidoir, le logement des galets d’entraînement et les pièces
métalliques en contact avec le fil de soudage sont sous tension. Des
matériels mal installés ou mal mis à la terre présentent un danger.
D
D
Ne jamais toucher les pièces électriques sous tension.
Porter des gants et des vêtements de protection secs ne comportant
pas de trous.
D
S’isoler de la pièce et de la terre au moyen de tapis ou d’autres
moyens isolants suffisamment grands pour empêcher le contact phy-
sique éventuel avec la pièce ou la terre.
Ne pas se servir de source électrique àcourant électrique dans les zones
humides, dans les endroits confinés ou là où on risque de tomber.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
Le soudage génère des fumées et des gaz. Leur
D
D
D
D
inhalation peut être dangereux pour votre santé.
Se servir d’une source électrique àcourant électrique UNIQUEMENT si le
procédé de soudage le demande.
D
Eloigner votre tête des fumées. Ne pas respirer
les fumées.
Si l’utilisation d’une source électrique àcourant électrique s’avère néces-
saire, se servir de la fonction de télécommande si l’appareil en est équipé.
D
A l’intérieur, ventiler la zone et/ou utiliser un échappement au niveau
de l’arc pour l’évacuation des fumées et des gaz de soudage.
Si la ventilation est insuffisante, utiliser un respirateur à alimenta-
tion d’air homologué.
Couper l’alimentation ou arrêter le moteur avant de procéder à l’instal-
lation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de
sécurité).
Installer et mettre à la terre correctement cet appareil conformément à
son manuel d’utilisation et aux codes nationaux, provinciaux et
municipaux.
Toujours vérifier la terre du cordon d’alimentation – Vérifier et s’assu-
rer que le fil de terre du cordon d’alimentation est bien raccordé à la
borne de terre du sectionneur ou que la fiche du cordon est raccordée
à une prise correctement mise à la terre.
En effectuant les raccordements d’entrée fixer d’abord le conducteur
de mise à la terre approprié et contre-vérifier les connexions.
Vérifier fréquemment le cordon d’alimentation pour voir s’il n’est pas
endommagé ou dénudé – remplacer le cordon immédiatement s’il est
endommagé – un câble dénudé peut provoquer une électrocution.
D
D
Lire les spécifications de sécurité des matériaux (MSDSs) et les
instructions du fabricant concernant les métaux, les consomma-
bles, les revêtements, les nettoyants et les dégraisseurs.
Travailler dans un espace fermé seulement s’il est bien ventilé ou en
portant un respirateur à alimentation d’air. Demander toujours à un
surveillant dûment formé de se tenir à proximité. Des fumées et des
gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxy-
gène provoquant des blessures ou des accidents mortels. S’assu-
rer que l’air de respiration ne présente aucun danger.
Ne pas souder dans des endroits situés à proximité d’opérations de
dégraissage, de nettoyage ou de pulvérisation. La chaleur et les
rayons de l’arc peuvent réagir en présence de vapeurs et former des
gaz hautement toxiques et irritants.
Ne pas souder des métaux munis d’un revêtement, tels que l’acier
galvanisé, plaqué en plomb ou au cadmium à moins que le revête-
ment n’ait été enlevé dans la zone de soudure, que l’endroit soit bien
ventilé, et si nécessaire, en portant un respirateur à alimentation
d’air. Les revêtements et tous les métaux renfermant ces éléments
peuvent dégager des fumées toxiques en cas de soudage.
D
D
D
D
D
D
D
D
D
Mettre l’appareil hors tension quand on ne l’utilise pas.
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffi-
sante ou mal épissés.
Ne pas enrouler les câbles autour du corps.
D
D
Si la pièce soudée doit être mise à la terre, le faire directement avec un
câble distinct.
D
Ne pas toucher l’électrode quand on est en contact avec la pièce, la
terre ou une électrode provenant d’une autre machine.
OM-1582 Page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
LES RAYONS DE L’ARC peuvent pro-
voquer des brûlures dans les yeux et
sur la peau.
LES ACCUMULATIONS DE GAZ ris-
quent de provoquer des blessures ou
même la mort.
Le rayonnement de l’arc du procédé de soudage
génère des rayons visibles et invisibles intenses
(ultraviolets et infrarouges) susceptibles de provoquer
des brûlures dans les yeux et sur la peau. Des étincelles sont projetées
pendant le soudage.
D
Fermer l’alimentation du gaz protecteur en cas de
non utilisation.
D
Veiller toujours à bien aérer les espaces confinés ou se servir d’un respi-
rateur d’adduction d’air homologué.
D
Porter un casque de soudage muni d’un écran de filtre approprié pour
protéger votre visage et vos yeux pendant le soudage ou pour regar-
der (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).
DES PIÈCES CHAUDES peuvent pro-
voquer des brûlures graves.
D
D
Porter des protections approuvés pour les oreilles si le niveau sondre est
trop élevé.
Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair
et de l’éblouissement; demander aux autres personnes de ne pas re-
garder l’arc.
Porter des vêtements de protection constitué dans une matière dura-
ble, résistant au feu (cuir ou laine) et une protection des pieds.
D
D
Ne pas toucher des parties chaudes à mains nues
Prévoir une période de refroidissement avant
d’utiliser le pistolet ou la torche.
D
LE SOUDAGE peut provoquer un
incendie ou une explosion.
Le soudage effectué sur des conteneurs fermés tels
que des réservoirs, tambours ou des conduites peut
provoquer leur éclatement. Des étincelles peuvent être
projetées de l’arc de soudure. La projection d’étincel-
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
D
D
Porteurs de stimulateur cardiaque, restez à distance.
Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’approcher
des opérations de soudage à l’arc, de gougeage ou
de soudage par points.
les, des pièces chaudes et des équipements chauds peut provoquer des
incendies et des brûlures. Le contact accidentel de l’électrode avec des
objets métalliques peut provoquer des étincelles, une explosion, un
surchauffement ou un incendie. Avant de commencer le soudage, vérifier
et s’assurer que l’endroit ne présente pas de danger.
D
D
D
Se protéger et d’autres personnes de la projection d’étincelles et de
LE BRUIT peut affecter l’ouïe.
métal chaud.
Ne pas souder dans un endroit là où des étincelles peuvent tomber sur
des substances inflammables.
Le bruit des processus et des équipements peut affecter
l’ouïe.
Déplacer toutes les substances inflammables à une distance de 10,7
m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneuse-
ment avec des protections homologués.
Des étincelles et des matériaux chauds du soudage peuvent facile-
ment passer dans d’autres zones en traversant de petites fissures et
des ouvertures.
D
Porter des protections approuvés pour les oreilles si
le niveau sondre est trop élevé.
D
D
D
D
Surveiller tout déclenchement d’incendie et tenir un extincteur à proxi-
Si des BOUTEILLES sont endomma-
gées, elles pourront exploser.
mité.
Le soudage effectué sur un plafond, plancher, paroi ou séparation
peut déclencher un incendie de l’autre côté.
Des bouteilles de gaz protecteur contiennent du gaz
sous haute pression. Si une bouteille est endomma-
gée, elle peut exploser. Du fait que les bouteilles de gaz
font normalement partie du procédé de soudage, les
Ne pas effectuer le soudage sur des conteneurs fermés tels que des
réservoirs, tambours, ou conduites, à moins qu’ils n’aient été prépa-
rés correctement conformément à AWS F4.1 (voir les normes de
sécurité).
Brancher le câble sur la pièce le plus près possible de la zone de sou-
dage pour éviter le transport du courant sur une longue distance par
des chemins inconnus éventuels en provoquant des risques d’élec-
trocution et d’incendie.
Ne pas utiliser le poste de soudage pour dégeler des conduites ge-
lées.
En cas de non utilisation, enlever la baguette d’électrode du porte-
électrode ou couper le fil à la pointe de contact.
Porter des vêtements de protection dépourvus d’huile tels que des
gants en cuir, une chemise en matériau lourd, des pantalons sans re-
vers, des chaussures hautes et un couvre chef.
Avant de souder, retirer toute substance combustible de vos poches
telles qu’un allumeur au butane ou des allumettes.
manipuler avec précaution.
D
D
D
D
Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, du laitier, des flammes ouvertes, des étin-
celles et des arcs.
Placer les bouteilles debout en les fixant dans un support stationnai-
re ou dans un porte-bouteilles pour les empêcher de tomber ou de
se renverser.
Tenir les bouteilles éloignées des circuits de soudage ou autres cir-
cuits électriques.
Ne jamais placer une torche de soudage sur une bouteille à gaz.
Une électrode de soudage ne doit jamais entrer en contact avec une
D
D
D
D
D
bouteille.
D
D
D
Ne jamais souder une bouteille pressurisée – risque d’explosion.
Utiliser seulement des bouteilles de gaz protecteur, régulateurs,
tuyaux et raccords convenables pour cette application spécifique;
les maintenir ainsi que les éléments associés en bon état.
DES PARTICULES VOLANTES
peuvent blesser les yeux.
D
D
D
Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la
bouteille.
Maintenir le chapeau de protection sur la soupape, sauf en cas d’uti-
lisation ou de branchement de la bouteille.
Lire et suivre les instructions concernant les bouteilles de gaz com-
primé, les équipements associés et les publications P-1 CGA énu-
mérées dans les normes de sécurité.
D
Le soudage, l’écaillement, le passage de la pièce
à la brosse en fil de fer, et le meulage génèrent
des étincelles et des particules métalliques vo-
lantes. Pendant la période de refroidissement des soudures, elles ris-
quent de projeter du laitier.
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.
OM-1582 Page 6
Download from Www.Somanuals.com. All Manuals Search And Download.
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance
Risque D’INCENDIE OU
D’EXPLOSION.
DES ORGANES MOBILES peuvent
provoquer des blessures.
D
Ne pas placer l’appareil sur, au-dessus ou à proxi-
mité de surfaces infllammables.
D
D
Rester à l’écart des organes mobiles comme le
ventilateur.
Maintenir fermés et fixement en place les portes,
panneaux, recouvrements et dispositifs de
protection.
D
D
Ne pas installer l’appareil à proximité de produits inflammables
Ne pas surcharger l’installation électrique – s”assurer que l’alimen-
tation est correctement dimensionné et protégé avant de mettre
l’appareil en service.
LE RAYONNEMENT HAUTE FRÉ-
QUENCE (H.F.) risque de provoquer
des interférences.
LA CHUTE DE L’APPAREIL peut
blesser.
D
Le rayonnement haute frequence peut provoquer
des interférences avec les équipements de ra-
dio–navigationet de communication, les services
de sécurité et les ordinateurs.
D
D
Utiliser l’anneau de levage uniquement pour sou-
lever l’appareil, NON PAS les chariot, les bouteil-
les de gaz ou tout autre accessoire.
D
Demander seulement à des personnes qualifiées familiarisées
avec des équipements électroniques de faire fonctionner l’installa-
tion.
L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences résultant de l’installation.
Utiliser un engin d’une capacité appropriée pour
soulever l’appareil.
D
En utilisant des fourches de levage pour déplacer l’unité, s’assurer
que les fourches sont suffisamment longues pour dépasser du côté
opposé de l’appareil.
D
D
Si le FCC signale des interférences, arrêter immédiatement l’appa-
reil.
L’EMPLOI EXCESSIF peut
SURCHAUFFER L’ÉQUIPEMENT.
D
D
Effectuer régulièrement le contrôle et l’entretien de l’installation.
Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance
correcte et utiliser une terre et et un blindage pour réduire les interfé-
rences éventuelles.
D
D
Prévoir une période de refroidissement, respec-
ter le cycle opératoire nominal.
Réduire le courant ou le cycle opératoire avant de
recommancer le soudage.
LE SOUDAGE À L’ARC risque de
D
Ne pas obstruer les passages d’air du poste.
provoquer des interférences.
LES CHARGES ÉLECTROSTATI-
QUES peuvent endommager les cir-
cuits imprimés.
D
L’énergie électromagnétique risque de provoquer
des interférences pour l’équipement électronique
sensible tel que les ordinateurs et l’équipement
commandé par ordinateur tel que les robots.
D
D
Veiller à ce que tout l’équipement de la zone de soudage soit com-
D
D
Établir la connexion avec la barrette de terre
patible électromagnétiquement.
avant de manipuler des cartes ou des pièces.
Pour réduire la possibilité d’interférence, maintenir les câbles de
soudage aussi courts que possible, les grouper, et les poser aussi
bas que possible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement
électronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre
conformément à ce mode d’emploi.
En cas d’interférences après avoir pris les mesures précédentes, il
incombe à l’utilisateur de prendre des mesures supplémentaires tel-
les que le déplacement du poste, l’utilisation de câbles blindés, l’uti-
lisation de filtres de ligne ou la pose de protecteurs dans la zone de
travail.
Utiliser des pochettes et des boîtes antistatiques
pour stocker, déplacer ou expédier des cartes de
circuits imprimes.
D
D
D
DES ORGANES MOBILES peuvent
provoquer des blessures.
D
D
Ne pas s’approcher des organes mobiles.
Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
LES FILS DE SOUDAGE peuvent pro-
voquer des blessures.
D
D
Porteurs de stimulateur cardiaque, restez à dis-
D
D
Ne pas appuyer sur la gachette avant d’en avoir
reçu l’instruction.
tance.
Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’appro-
cher des opérations de soudage à l’arc, de gou-
geage ou de soudage par points.
Ne pas diriger le pistolet vers soi, d’autres person-
nes ou toute pièce mécanique en engageant le fil
de soudage.
OM-1582 Page 7
Download from Www.Somanuals.com. All Manuals Search And Download.
1-4. Principales normes de sécurité
Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel-
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.
RecommendedSafe Practice for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances, norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126
Safe Practices For Occupation And Educational Eye And Face Protec-
tion, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.
NationalElectrical Code, NFPA Standard 70, de la National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.
Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
1-5. Information sur les champs électromagnétiques
Données sur le soudage électrique et sur les effets, pour l’organisme,
des champs magnétiques basse fréquence
Afin de réduire les champs électromagnétiques dans l’environnement
de travail, respecter les consignes suivantes :
1
Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.
Le courant de soudage, pendant son passage dans les câbles de sou-
dage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir ex-
aminé plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National Re-
search Council a conclu: “L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiqueset champs électriques à haute fréquence représente un
risque à la santé humaine”. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les con-
clusions finales de la recherche soient établies, il vous serait
souhaitablede réduire votre exposition aux champs électromagnéti-
ques pendant le soudage ou le coupage.
2
3
Mettre tous les câbles du côté opposé de l’opérateur.
Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.
4
5
Garder le poste de soudage et les câbles le plus loin possible de
vous.
Relier la pince de masse le plus près possible de la zone de
soudure.
Consignes relatives aux stimulateurs cardiaques :
Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est
alors recommandé de respecter les consignes ci–dessus.
OM-1582 Page 8
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 2 – DEFINITIONS
2-1. Warning Label Definitions
A. Warning! Watch Out! There
are possible hazards as
shown by the symbols.
B. Drive rolls can injure fingers.
A
B
C
C. Welding wire and drive parts
are at welding voltage during
operation – keep hands and
metal objects clear.
1
Electric shock can kill.
1.1 Wear dry insulating gloves.
Do not touch electrode with
bare hand. Do not wear wet or
damaged gloves.
1.2 Protect yourself from electric
shock by insulating yourself
from work and ground.
1
2
1.1
2.1
3.1
4.1
1.2
1.3
1.3 Disconnect input plug or
power before working on
machine.
2
Breathing welding fumes can
be hazardous to your health.
2.2
2.3
2.1 Keep your head out of the
fumes.
2.2 Use forced ventilation or local
exhaust to remove the fumes.
2.3 Use ventilating fan to remove
fumes.
3
4
5
3.2
3.3
3
Welding sparks can cause
explosion or fire.
3.1 Keep flammables away from
welding. Don’t weld near
flammables.
3.2 Welding sparks can cause
fires. Have a fire extinguisher
nearby and have a watch
person ready to use it.
+ + +
3.3 Do not weld on drums or any
closed containers.
4
Arc rays can burn eyes and
injure skin.
6
4.1 Wear hat and safety glasses.
Use ear protection and button
shirt collar. Use welding
helmet with correct shade of
filter. Wear complete body
protection.
+
S-178 936
5
Become trained and read the
instructions before working on
the machine or welding.
6
Do not remove or paint over
(cover) the label.
OM-1582 Page 9
Download from Www.Somanuals.com. All Manuals Search And Download.
2-2. Rating Label For CE Products
For label location
see Section 4-4.
S/N:
U1
50/60 Hz
IP 21
24 V
10.0A
1
=
I =
1
U2
=
I =
750 A
2
100 V
X 100 %
ST-178 794-A
2-3. Symbols And Definitions
Some symbols are found only on CE products.
Note
Amperes
Volts
AlternatingCurrent
Primary Voltage
Duty Cycle
A
IP
V
Hz
X
Degree Of
Protection
Hertz
Wire Feed
U1
Jog
Output
Trigger
Line Connection
Trigger Hold Off
Press To Set
Load Voltage
Trigger Hold On
U2
Purge
Burnback Time
Increase
Spot Weld Time
Preflow Time
Spot Weld
Continuous Weld
Read Instructions
Postflow Time
Rated Current
Primary Current
I1
I2
OM-1582 Page 10
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 3 – INTRODUCTION
3-1. Specifications
Welding
Circuit
Rating
Type of Input
Power
Welding Power
Source Type
Wire Feed
Speed Range
Wire Diameter
Range
IP
Rating
Overall
Dimensions
Weight
Standard: 50 To
780 ipm (1.3 To
19.8 mpm)
Length: 32 in
(812 mm)
100 Volts,
750
Amperes,
100% Duty
Cycle
.023 To 1/8 in
(0.6 To 3.2 mm)
24 Volts AC
Single-Phase
10 Amperes
50/60 Hertz
Constant Voltage (CV)
DC With 14-Pin And
Contactor Control
Width: 18 in
(457 mm)
78 lb
(35 kg)
IP 23
Max Spool
Weight: 60 lb
(27 kg)
Optional High
Speed: 90 To
1400 ipm (2.3 To
35.6 mpm)
Height: 14 in
(356 mm)
SECTION 4 – INSTALLATION
4-1. Site Selection
1
2
3
4
Wire Feeder
Lifting Eye
Rubber Feet
Slot
5
6
Choose slot that allows all rubber
feet to sit securely on top of welding
power source.
2
4
1
5
6
Wire Spool/Reel
Gas Cylinder (Customer
Supplied)
7
7
Welding Power Source
Y
Do not put feeder where
welding wire hits cylinder.
3
Y
Do not move or operate
equipmentwhen it could tip.
Ref. ST-152 468-A / ST-152 566-B
OM-1582 Page 11
Download from Www.Somanuals.com. All Manuals Search And Download.
4-2. Gun Recommendation Table
Process
Gun
GMAW – Hard or Cored Wires
Roughneck C-Series Guns: 300, 400, 500,
And 600 Amp.
FCAW – Self-Shielding Wires
FC-1260 Or FC-1150
4-3. Equipment Connection Diagrams
1
2
3
4
5
6
7
8
Welding Power Source
Contactor Control/Power Cord
Positive (+) Weld Cable
Negative (–) Weld Cable
Workpiece
1
2
Gun
Wire Feeder
10
PSA-2 Control (Optional)
Use with welding power sources
supplying 115 volts ac power.
3
9
Gas Hose
10 Gas Cylinder
4
5
9
6
7
1
10
2
3
4
5
9
8
6
7
152 616-C / 152 615-C
OM-1582 Page 12
Download from Www.Somanuals.com. All Manuals Search And Download.
4-4. Rear Panel Connections
1
2
”Y” Adapter Gas Hose
(Supplied)
Shielding Gas Valve Fitting
Requires fitting with 5/8-18 right-
hand threads.
6
6
7
8
9
3
4
5
6
Weld Cable Terminal
Jumper Weld Cable
Weld Cable
Optional Current Sensor
Connections
7
8
9
14-Pin Cord
Power Switch
Rating Label Location
1
4
2
5
3
4
5
Tools Needed:
9/16, 5/8 in
3/16 in
Ref. 800 353-B
4-5. 14-Pin Plug Information
Pin*
Pin Information
A
B
G
C
D
E
H
F
24 volts ac with respect to socket G.
Contact closure to A completes 24 volts ac contactor control circuit.
Circuit common for 24 volts AC circuit.
J
A
K
I
B
C
+10 volts dc output to remote control with respect to socket D.
Remote control circuit common.
L
H
N
M
E
G
D
F
0 to +10 volts dc input command signal from remote control with respect to socket D.
Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.
Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.
*The remaining pins are not used.
OM-1582 Page 13
Download from Www.Somanuals.com. All Manuals Search And Download.
4-6. Wire Type, Size, And Feed Speed Capability Table
Motor Speed
Standard
Wire Type
Wire Size
Feed Speed Capability
All
All
All
.023 To 5/64 in (0.6 To 2 mm)
3/32 To 7/64 in (2.4 To 2.8 mm)
1/8 in (3.2 mm)
50 To 780 ipm (1.3 To 19.8 mpm)
50 To 700 ipm (1.3 To 17.8 mpm)
50 To 300 ipm (1.3 To 7.6 mpm)
Standard
Standard
Optional High
Speed
All
.023 To 5/64 in (0.6 To 2 mm)
92 To 1440 ipm (2.3 To 35.6 mpm)
4-7. Motor Start Control
To change wire feed starting speed,
proceed as follows:
Turn Off wire feeder and welding
power source.
Remove wrapper.
1
Front Panel
2
Front panel shown open for illustra-
tion purposes.
2
Left Side Inner Control Panel
It may be necessary to remove pan-
el to access Motor Start Control.
Remove panel only as far as re-
quired if options are attached to
panel.
3
4
Motor Board PC1
1
Motor Start Control Poten-
tiometer R70
Turn potentiometer clockwise to in-
crease time it takes the motor to
ramp up to speed. Remove protec-
tive white rubber cap before making
adjustment. Adjust potentiometer
R70 using a small nonconductive
screwdriver.
Reinstall left side inner control pan-
el if it was removed.
Reinstall wrapper.
3
Tools Needed:
Non-Conductive
1/4 in
Ref. 143 259-G / Ref. SB-183 121-C
OM-1582 Page 14
Download from Www.Somanuals.com. All Manuals Search And Download.
4-8. Rotating The Drive Assembly
Remove screws (6) from front edge
of wrapper, and loosen screws on
back edge of wrapper.
1
2
Front Panel
Drive Assembly Rotation
Adjustment Opening
3
Drive Assembly
2
1
3
Tools Needed:
1/4 in
3/16 in
Ref. 143 259-G / Ref. ST-153 093-A
OM-1582 Page 15
Download from Www.Somanuals.com. All Manuals Search And Download.
4-9. Installing And Threading Welding Wire
about 2 in (51 mm) from nonconductive
surface and press gun trigger to feed wire
against surface. Tighten knob so wire does
not slip. Do not overtighten. If contact tip is
completely blocked, wire should slip at the
feeder (see pressure adjustment above).
. Be sure that outlet cable has proper size . For soft wire or small diameter stainless
liner for the welding wire size. When
installing gun, position liner extending
from outlet wire guide as close as pos-
sible to drive rolls without touching.
steel wire, use 2 drive rolls and set drive
roll pressure from 0 to a maximum of 4
on the pressure indicator scale (so that
only the inner spring is compressed).
This setting will generally give the best
performancefor these types of wires.
Install gun. Lay gun cable out straight. Cut off
end of wire. Push wire through guides up to
drive rolls; continue to hold wire. Press Jog
button to feed wire out gun.
Cut wire off. Close cover.
To adjust drive roll pressure, hold nozzle
Install wire guides and
anti-wear guide.
If necessary, move hub and spool
support so wire runs straight from
the spool through the drive rolls.
Install wire spool. Adjust tension
nut so wire is taut when wire feed
stops.
Install drive rolls.
Pressure
Indicator
Scale
Pressure
Adjust
NONCONDUCTIVE
NONCONDUCTIVE
SURFACE
SURFACE
No Wire Slip
Wire Slips
Tools Needed:
3/16, 5/64 in
15/16, 3/8 in
Ref. ST-156 929-A / Ref. SC-150 922 / Ref. ST-156 930 / S-0627-A
OM-1582 Page 16
Download from Www.Somanuals.com. All Manuals Search And Download.
4-10. Optional Equipment DIP Switch Settings
. If wire feeder is equipped with a voltage sensing lead, set DIP switch S3
to the OFF position (up). If wire feeder is NOT equipped with a voltage
sensing lead, set DIP switch S3 to the ON position (down).
Spot Time
Range Selection
Option Interface
Standard Settings
O F F
Long Spot
Time
0-5 Seconds
1
2
Or
O F F
Short Spot
Time
0-2.5 Seconds
2
1
X Means switch can be in either position.
.
Means switch must be in this position.
Digital Meter Functions
Standard
Motor
Standard
Motor
High Speed
Motor
High Speed
Motor
Inches/Minute Meters/Minute Inches/Minute Meters/Minute
Or
Or
Voltage Sensing Function
Arc Voltage Sensing Using
Feedback From Welding
Power Source
Arc Voltage Sensing Using
Voltage Sensing Lead
Or
DIP Switch S3
Set To OFF
DIP Switch S3
Set To ON
Tools Needed:
1/4 in
Ref. 143 259-G / Ref. SA-146 866-B / Ref. SA-148 666-E / Ref. SA-150 588-D
OM-1582 Page 17
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 5 – OPERATION
5-1. Front Panel Controls
1
2
3
4
Schedule A
Schedule B
3
4
5
6
5
6
7
7
8
9
8
9
10
10
ST-152 647
1
2
Voltmeter (Optional) (See Section
4-10)
Press and hold button to preset Schedule B
wire feed speed and/or voltage.
. For dual schedule applications, a dual
schedule switch is required for the gun.
Obtain a proper dual schedule switch
and install according to its instructions.
9
Left And Right Indicator Lights
Wire Speed Meter (Optional)
10 Jog/Purge Switch
Factory set to display inches per minute. If
display of meters per minute is desired, see
Section 4-10.
5
6
Schedule B Indicator Light (Optional)
Push up to momentarily feed welding wire at
speed set on Wire Speed control without en-
ergizing welding circuit or shielding gas
valve.
Schedule B Wire Speed Control
(Optional)
3
Schedule A Wire Speed Control
The scale is calibrated in inches per minute
x 100 and meter per minute.
Push down to momentarily energize gas
valve to purge air from gun or adjust gas reg-
ulator.
7
8
Schedule B Voltage Control
(Optional)
4
Schedule A Voltage Control
(Optional)
Press To Set Button (Optional)
Center position is off.
OM-1582 Page 18
Download from Www.Somanuals.com. All Manuals Search And Download.
5-2. Overload Protection And Optional Side Panel Controls
3
8
2
6
7
4
5
1
802 433-A
1
Circuit Breaker CB1
4
Spot Continuous Switch
6
Burnback Control
Control adjusts time welding wire is ener-
gized after wire feed stops.
CB1 protects wire feed motor from overload.
Press to reset.
Switch selects an untimed continuous weld
or a timed spot weld.
7
Run-In Control
2
Preflow Control
5
Trigger Hold Switch (Optional)
Control sets run-in wire speed before arc ini-
tiation.
Control sets time gas flows before welding
wire is energized.
Push up to weld without holding gun trigger
throughout the weld cycle.
8
Postflow Control
3
Spot Time Control
To start weld, press and release gun trigger
Control sets time gas flows after completion
of burnback.
Factory set for 0 to 5 seconds of spot time. within three seconds after an arc has been
If 0 to 2.5 seconds is desired, see Section
4-10.
struck. To end weld, press and release gun
trigger.
Close side door.
SECTION 6 – MAINTENANCE AND TROUBLESHOOTING
6-1. Routine Maintenance
Y
Disconnectpower before maintaining.
3 Months
Repair or
replace
cracked
weld
Clean and
tighten
weld
Replace
unreadable
labels.
terminals.
cable.
Replace
cracked
parts.
Check
14-pin
cord.
Check gas
hose and
fittings.
Check
gun
cable.
6 Months
Blow out or vacuum
inside. During heavy
service, clean
Clean
drive
rolls.
OR
monthly.
OM-1582 Page 19
Download from Www.Somanuals.com. All Manuals Search And Download.
6-2. Troubleshooting
Y
Disconnect power before troubleshooting
Remedy
Trouble
Wire feeds, shielding gas flows, but elec- Check interconnecting cord connections. If secure, check cord for continuity and repair or replace (see
trode wire is not energized. Sections 4-3 and 4-4).
Wire feeder is on, meter(s) do not light Check and reset CB1 (see Section 5-2).
up, motor does not run, gas valve and
welding power source contactor do not
pull in.
Electrode wire feeding stops or feeds er- Check gun trigger connection. See gun Owner’s Manual.
ratically during welding.
Check gun trigger. See gun Owner’s Manual.
Readjust hub tension and drive roll pressure (see Section 4-9).
Change to correct size drive roll (see Table 8-1).
Clean or replace dirty or worn drive roll.
Incorrect size or worn wire guides.
Replace contact tip or liner. See gun Owner’s Manual.
Remove weld spatter or foreign matter from around nozzle opening.
Have Factory Authorized Service Agency check drive motor or motor control board PC1.
Motor runs slowly.
Check for correct input voltage.
Wire does not feed until trigger is pulled, Check for a short between welding gun trigger leads and weld cable. Repair short or replace welding gun.
but continues to feed after trigger is re-
leased, and trigger hold is not on.
Gas valve in feeder is rattling loudly Check for a short between welding gun trigger leads and weld cable. Repair short or replace welding gun.
along with possible erratic or slow wire
feed speed.
Unit does not switch out of Run-In
Speed.
When using this unit with certain older style Miller CV power sources, a weld current sensor
(Part No. 160 963) must be used. Power sources include the Deltaweld prior to Serial No. KG141349
and the Dimension prior to Serial No. KC253517.
Wire feeder power is on, displays light Check welding gun trigger leads for continuity, and repair leads or replace gun.
up, but unit is inoperative.
ScheduleA Wire Feed Speed works, but DIP Switch S1(1) on Option Interface Board PC70 must be in the On position (see Section 4-10).
Schedule B Wire Feed Speed does not
work or is erratic.
Wire Feed Speed Meter display does not Set DIP Switch S2 on Meter Board PC60 in Inches/Minute mode (see Section 4-10).
match actual wire feed speed.
Actual arc voltage display on meter is Set DIP Switch S2 on Meter Board PC60 in Voltage Monitor mode (see Section 4-10).
held after trigger is released, or arc volt-
age does not change while welding.
OM-1582 Page 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
OM-1582 Page 21
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 7 – ELECTRICAL DIAGRAM
Figure 7-1. Circuit Diagram
OM-1582 Page 22
Download from Www.Somanuals.com. All Manuals Search And Download.
197 518–A
OM-1582 Page 23
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 8 – PARTS LIST
. Hardware is common and
not available unless listed.
2
1
3
4
5
6
7
8
30
7
6
5
9
29
10
27
28
12
26
Fig 8-2
11
25
20
Fig 8-5
24
23
21
19
22
18
17
16
13
15
Fig 8-5
14
143 225-K
Figure 8-1. Main Assembly
OM-1582 Page 24
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
No.
Part
No.
Description
Figure 8-1. Main Assembly
Quantity
. . 1 . . . . . . . . . . . . . . 143 160 . . HUB & SPINDLE ASSEMBLY, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 2 . . . . . . . . . . . . . . 058 427 . . . . RING, retaining spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 3 . . . . . . . . . . . . . . 180 573 . . . . SHAFT, support spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 4 . . . . . . . . . . . . . . 010 233 . . . . SPRING, cprsn .970 OD x .120 wire x 1.250pld . . . . . . . . . . . . . . . . . . . . . 1
. . 5 . . . . . . . . . . . . . . 057 971 . . . . WASHER, flat stl keyed 1.500dia x .125thk . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 6 . . . . . . . . . . . . . . 010 191 . . . . WASHER, fbr .656 ID x 1.500 OD x .125thk . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 7 . . . . . . . . . . . . . . 058 628 . . . . WASHER, brake stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 8 . . . . . . . . . . . . . . 058 428 . . . . HUB, spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 9 . . . . . . . . . . . . . . 071 730 . . . . TUBING, stl .875 OD x 12ga wall x 2.375 . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 10 . . . . . . . . . . . . . 135 205 . . . . NUT, stl slflkg hex reg .625-11 w/nylon insert . . . . . . . . . . . . . . . . . . . . . . . 1
. . 11 . . . . . . . . . . . . . . 141 411 . . SUPPORT, spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 12 . . . . . . . . . . . . . 142 838 . . BRACKET, mtg spool RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 13 . . . . . . . . . . . . . 134 306 . . FOOT, rubber 1.250dia x 1.375 high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . 14 . . . . . . . . . . . . . 139 226 . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 15 . . . . . . . . . . . . . . Fig 8-5 . . WIRE DRIVE ASSEMBLY, RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 16 . . . . . . . . . . . . . 159 647 . . INSULATOR, motor clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 17 . . . . . . . . . . . . . 159 360 . . INSULATOR, screw machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
. . 18 . . . . . . . . . . . . . 602 009 . . SCREW, cap stl sch .250-20 x 1.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 19 . . . . . . . . . . . . . 156 243 . . CLAMP, motor top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 20 . . . . . . . . . . . . . 083 639 . . WEATHERSTRIPPING, adh .125 x 1.500 (order by ft) . . . . . . . . . . . . . . . 1ft
. . 21 . . . . . . . . . . . . . 159 646 . . CLAMP, motor base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 22 . . . . . . . . . . . . . 145 639 . . STRIP, buna N compressed sheet .062 x 4.000 x 4.000 . . . . . . . . . . . . . . . 2
. . 23 . . . . . . . . . . . . . 143 152 . . SCREW, cap stl sch .250-20 x 5.000 (LH only) . . . . . . . . . . . . . . . . . . . . . . . 2
. . 24 . . . . . . . . . . . . . 139 752 . . SPACER, stl .500 OD x 12ga wall x 3.750 (LH only) . . . . . . . . . . . . . . . . . . . 2
. . 25 . . . . . . . . . . . . . . Fig 8-5 . . WIRE DRIVE ASSEMBLY, LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 26 . . . . . . . . . . . . . . Fig 8-2 . . CONTROL BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 27 . . . . . . . . . . . . ♦108 008 . . REEL, wire 60 lb (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 28 . . . . . . . . . . . . . 124 900 . . . . SUPPORT, reel spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 29 . . . . . . . . . . . . +168 104 . . . . RETAINER, spool support (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 166 594 . . . . . . LABEL, caution falling wire reel can cause damage . . . . . . . . . . . . . . . . 1
. . 30 . . . . . . . . . . . . . 168 103 . . . . NUT, spanner retaining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 143 838 . . CABLE, weld 26 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 164 059 . . HOSE, gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
♦OPTIONAL
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-1582 Page 25
Download from Www.Somanuals.com. All Manuals Search And Download.
. Hardware is common and
not available unless listed.
143 226-G
Figure 8-2. Control Box
OM-1582 Page 26
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 8-2. Control Box (Fig 8-1 Item 26)
. . 1 . . . . . . . . . . . . . . . . . 139 235 . . . PANEL, side lower LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 2 . . . . . . . . . . . . . . . . . . Fig 8-4 . . . CONTROL PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 3 . . . . . PC2 . . . . . . 134 994 . . . CIRCUIT CARD, tach jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . ♦180 314 . . . DIGITAL DISPLAY, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . 132 611 . . . . OPTICAL ENCODER DISC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 3 . . . . . PC50 . . . . . . 132 370 . . . . CIRCUIT CARD, tachometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . 097 132 . . . . STAND-OFF, 6-32 x .375 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . . R3,4 . . . . . . 603 856 . . . . POTENTIOMETER, WW sltd sft 10/T 2W 10K ohm
(Wire Feed Speed A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . PLG5 . . . . . . 130 203 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG62 . . . . . 131 055 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG64 . . . . . 167 361 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG95 . . . . . 115 092 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . 138 045 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . R75,85 . . . . . 603 856 . . . . POTENTIOMETER, WW sltd sft 10/T 2W 10K ohm
(Voltage Control A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . PLG84,86,97 . . 131 204 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . . . PLG41,47,49,85 . 131 203 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . PLG41 . . . . . 115 090 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG19 . . . . . 151 490 . . . . CONNECTOR, rect 21P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG60,63 . . . . 138 045 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . . . 097 922 . . . . KNOB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
see Figure 8-3 & Figure 8-5 for additional parts
. . 4 . . . . . PC60 . . . . . . 157 719 . . . . CIRCUIT CARD, meter dual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PC51 . . . . . . 198 004 . . . . CIRCUIT CARD, digital tach . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 5 . . . . . . . . . . . . . . . . . 139 231 . . . CASE SECTION, bottom/rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 6 . . . . . PC1 . . . . . . 198 037 . . . CIRCUIT CARD, motor control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG1 . . . . . . 115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG2 . . . . . . 115 093 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG3 . . . . . . 115 094 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG4 . . . . . . 115 091 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG5 . . . . . . 130 203 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG6 . . . . . . 136 810 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 7 . . . . . . . . . . . . . . . . . 151 187 . . . LATCH, slide flush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 8 . . . . . CB1 . . . . . . 083 432 . . . CIRCUIT BREAKER, man reset 1P 10A 250V . . . . . . . . . . . . . . . . . . . . 1
. . 9 . . . . . . S1 . . . . . . . 111 997 . . . SWITCH, rocker SPST 10A 250VAC (Power Switch) . . . . . . . . . . . . . . . 1
. . 10 . . . . . . . . . . . . . . . . 134 201 . . . STAND-OFF SUPPORT, PC card .312/.375 . . . . . . . . . . . . . . . . . . . . . . 12
. . 11 . . . . . . . . . . . . . . . . 010 325 . . . BUSHING, strain relief .840 ID x .875mtg hole . . . . . . . . . . . . . . . . . . . . 1
. . 12 . . . . . . . . . . . . . . +139 229 . . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 13 . . . . . . . . . . . . . . . . 178 936 . . . LABEL, warning general precautionary . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 13 . . . . . . . . . . . . . . . . 134 464 . . . LABEL, warning CE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 14 . . . . . . . . . . . . . . . . 164 368 . . . CABLE, pwr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 15 . . . . . . . . . . . . . . . . 605 227 . . . NUT, nylon hex jam .750NPST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 16 . . . GS1,2 . . . . . 125 785 . . . VALVE, 24VAC 2 way custom port 1/8 orf . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 17 . . . . C1,2 . . . . . . 147 856 . . . CAPACITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 18 . . . CR101 . . . . . 072 817 . . . RELAY, encl 24VAC DPDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 19 . . . . SR1 . . . . . . 035 704 . . . RECTIFIER, integ 40A 800V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 20 . . . . . . . . . . . . . . . . 030 170 . . . BUSHING, snap-in nyl .750 ID x 1.000mtg hole . . . . . . . . . . . . . . . . . . . 3
. . 21 . . . . . . . . . . . . . . . . . Fig 8-3 . . . PANEL, front w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 22 . . . . PC3 . . . . . . 183 151 . . . CIRCUIT CARD, relay control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG92,94 . . . . 131 052 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . PLG93 . . . . . 115 093 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG95 . . . . . 135 409 . . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG96 . . . . . 131 204 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG98 . . . . . 115 094 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG11,17 . . . . 115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . PLG12,18 . . . . 135 409 . . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . . . 120 304 . . . BLANK, snap-in nyl .250mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
OM-1582 Page 27
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 8-2. Control Box (Fig 8-1 Item 26) (Continued)
. . . . . . . . . . . . . . . . . . . . . . 119 951 . . . BLANK, snap-in nyl .437mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
. . . . . . . . . . . . . . . . . . . . . . 107 983 . . . BLANK, snap-in nyl .500mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . . . 024 103 . . . BLANK, snap-in nyl .750mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . 000 527 . . . BLANK, snap-in nyl .875mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
♦OPTIONAL
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
. Hardware is common and
1
*
not available unless listed.
See Figure 8-2
1
3
*
2
4
12
6
11
*
11
*
*
*
9
10
7
5
8
*See Option that is applicable
143 227-D
Figure 8-3. Panel, Front w/Components
OM-1582 Page 28
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 8-3. Panel, Front w/Components (Fig 8-2 Item 21)
. . 1 . . . . . R1,2 . . . . . . . . 073 562 . . . POTENTIOMETER, C sltd sft 1/T 2W 10K ohm
(Wire Feed Speed A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 2 . . . . . . . . . . . . . . . . . . . 149 654 . . . PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 3 . . . . . . . . . . . . . . . . . . . 136 339 . . . COVER, opening meter (not used with digital display option) . . . . . . 2
. . 4 . . . . . . . . . . . . . . . . . . . 134 209 . . . NUT, speed push-on-type .250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 5 . . . . LED1,2 . . . . . . . 179 203 . . . LED, 5100 2.0V 20mA green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . . . ♦172 825 . . . DIGITAL DUAL SCHEDULE, RH (consisting of) . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . ♦173 748 . . . DIGITAL DUAL SCHEDULE, LH (consisting of) . . . . . . . . . . . . . . . . . 1
. . 4 . . . . . . . . . . . . . . . . . . . 134 209 . . . . NUT, speed push-on-type .250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 5 . . . LED71/81 . . . . . . 179 203 . . . . LED, 5100 2.0V 20mA green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG68/48 . . . . . . 131 204 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG72 . . . . . . . 131 054 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . R76,77/86,87 . . . . 603 856 . . . . POTENTIOMETER, WW sltd sft 10/T 2W 10K ohm
(Wire Feed Speed B/Voltage Control B) . . . . . . . . . . . . . . . . . . . . . . 2
. . 6 . . . . S71/81 . . . . . . . 150 982 . . . . SWITCH, PB MC SPDT 6A 125VAC (Press to Set) . . . . . . . . . . . . 1
. . 7 . . . . . . . . . . . . . . . . . . . 153 195 . . . . NUT, face . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 8 . . . . . . . . . . . . . . . . . . . 150 981 . . . . BUTTON, switch black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . 097 922 . . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
see Figure 8-4 For Additional Parts
. . 9 . . . . RC8,9 . . . . . . . 048 282 . . . CONNECTOR w/SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 10 . . . . S2,3 . . . . . . . . 134 846 . . . SWITCH, tgl SPTT 15A 125VAC (Jog/Purge) . . . . . . . . . . . . . . . . . . . 2
. . 11 . . . . . . . . . . . . . . . . . . 097 922 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE, (order by model and serial number) . . . . . . . . . . . . . . . 1
♦OPTIONAL
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-1582 Page 29
Download from Www.Somanuals.com. All Manuals Search And Download.
1
2
. Hardware is common and
not available unless listed.
3
8
7
9
10
6
4
11
5
146 340-B
Figure 8-4. Control Panel
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 8-4. Control Panel (Fig 8-2 Item 2)
. . 1 . . . . S31,32 . . . . . ♦011 770 . . . SWITCH, tgl SPDT 6A 125VAC (Trigger Hold/Spot) . . . . . . . . . . . . . 2
. . 2 . . . . . PC70 . . . . . ♦♦150 591 . . . . CIRCUIT CARD, option interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . PLG16,54,76 . ♦♦115 093 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . . . . . . PLG78,88 . . . ♦♦115 094 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . PLG79,89 . . . ♦♦115 091 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG80,90 . . . ♦♦135 531 . . . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG98 . . . . ♦♦131 056 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 3 . . . . . . . . . . . . . . . . ♦♦115 443 . . . . STAND-OFF, 6-32 x .750 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . . . . . . . . . . . ♦♦♦138 542 . . . SPOT/BURNBACK PREFLOW/POSTFLOW, RH . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . ♦♦♦138 547 . . . SPOT/BURNBACK PREFLOW/POSTFLOW, LH (consisting of) . . . 1
. . 4 . . . . . . . . . . . . . . . . . . . 126 689 . . . . STAND-OFF, 6-32 x 1.500 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . 5 . . . . . PC30 . . . . . . . . 188 834 . . . . CIRCUIT CARD, 4 in 1 timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . PLG1,21,31 . . . . . 115 092 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . . . . . . PLG22,32 . . . . . . 135 409 . . . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . PLG35 . . . . . . . 115 094 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG90 . . . . . . . 131 204 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG91 . . . . . . . 115 093 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 6 . . . . . . . . . . . . . . . . . . . 093 551 . . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . 7 . . . . . . . . . . . . . . . . . . . 180 636 . . . . PLATE, control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 8 . . . . . . . . . . . . . . . . . . . 133 344 . . . . PANEL, option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . 120 304 . . . . BLANK, snap-in nyl .250mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . ♦♦♦194 679 . . . RUN-IN CONTROL (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . 153 037 . . . . SWITCH, reed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . 079 878 . . . . HOUSING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . 079 535 . . . . TERMINAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . 079 531 . . . . CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . 048 834 . . . . CLAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 7 . . . . . . . . . . . . . . . . . . . 180 636 . . . . PLATE, control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 8 . . . . . . . . . . . . . . . . . . . 133 344 . . . . PANEL, option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 9 . . . . . . . . . . . . . . . . . . . 197 153 . . . . SPACER, mtg pc board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
OM-1582 Page 30
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 8-4. Control Panel (Fig 8-2 Item 2) (Continued)
. . 10 . . . . PC80 . . . . . . . . 196 746 . . . . CIRCUIT CARD, run-in control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 11 . . . . . . . . . . . . . . . . . . 093 551 . . . . KNOB, .125dia shaft w/.125 set screw . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . PLG16,54,76,76 . . . 115 093 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . PLG71,78,88 . . . . 115 094 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . . . PLG79,79,89,100 . . 115 091 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . PLG80,90,RC100 . . 135 531 . . . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . . . . . . . PLG98 . . . . . . . 131 056 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . RC70 . . . . . . . . 048 282 . . . . RECEPTACLE & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . 120 304 . . . . BLANK, snap-in nyl .250mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
. . 7 . . . . . . . . . . . . . . . . . . . 180 635 . . . PLATE, control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
♦Part of Optional 138 542 RH and 138 547 LH Spot/Burnback, Preflow/Postflow
♦♦Part of Optional 172 825 RH and 173 748 LH Digital Dual Schedule
♦♦♦OPTIONAL
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
. Hardware is common and
not available unless listed.
See Table 8-1 For
Drive Roll & Wire Guide Kits
137 222-P
Figure 8-5. Drive Assembly, Wire
OM-1582 Page 31
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
2
4
Drive
Roll
Drive
Roll
Figure 8-5. Drive Assembly, Wire (Fig 8-1 Items 15 & 25)
. . . 1 . . . . . . . . . . . . . . . 010 668 . . SCREW, cap stl sch .250-20 x 1.500 . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 4
. . . 2 . . . . . . . . . . . . . . . 172 075 . . CARRIER, drive roll w/components . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 4
. . . 3 . . . . . . . . . . . . . . . 149 962 . . SPACER, carrier drive roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 4
. . . 4 . . . . . . . . . . . . . . . 149 486 . . PIN, rotation arm rocker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 2
. . . 5 . . . . . . . . . . . . . . . 132 750 . . ARM, pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 2
. . . 6 . . . . . . . . . . . . . . . 150 520 . . SPACER, flat stl .257 ID x .619 OD x .105 . . . . . . . . . . . . . . . . . . . . 1 . . . . 2
. . . 7 . . . . . . . . . . . . . . . 133 493 . . RING, retaining ext .250 shaft x .025thk . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2
. . . 8 . . . . . . . . . . . . . . . 133 350 . . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 9 . . . . M1 . . . . . . 156 354 . . MOTOR, gear 1/8hp 24VDC 272RPM (consisting of) . . . . . . . . . . 1 . . . . 1
. . . 9 . . . . M1 . . . . ♦156 353 . . MOTOR, gear 1/8hp 24VDC 500RPM (consisting of) . . . . . . . . . . 1 . . . . 1
. . . . . . . . . . . . . . . . . . . . . 153 491 . . . . KIT, brush replacement (consisting of) . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . . . . . . . . . . . . . . . . . . . 153 492 . . . . . CAP, brush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2
. . . . . . . . . . . . . . . . . . . . *153 493 . . . . . BRUSH, carbon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2
. . . . . . . . . . . . . . . . . . . . . 184 136 . . . . KIT, brush holder replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 10 . . . . . . . . . . . . . . . 155 098 . . KIT, cover motor gearbox (consisting of) . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . . . . . . . . . . . . . . . . . . . 153 550 . . . . COVER, motor gearbox (consisting of) . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . . . . . . . . . . . . . . . . . . . 155 099 . . . . . GASKET, cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . . . . . . . . . . . . . . . . . . . 155 100 . . . . . SCREW, cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 . . . . 5
. . . . . . . . . . . . . . . . . . . . . 154 031 . . . . SPACER, locating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2
. . . . . . . . . . . . . . . . . . . . . 133 493 . . . . RING, rtng ext .250 shaft grv x .025thk . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 11 . . . . . . . . . . . . . . . 182 414 . . WASHER, flat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 12 . . . . . . . . . . . . . . . 182 415 . . PIN, cotter hair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 13 . . . . . . . . . . . . . . . 137 248 . . SPRING, indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 14 . . . . . . . . . . . . . . . 602 082 . . SCREW, mach stl rdh 8-32 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 15 . . . . . . . . . . . . . . . 602 200 . . WASHER, lock stl split No. 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 16 . . . . . . . . . . . . . . . 604 772 . . WASHER, flat stl SAE No. 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 17 . . . . . . . . . . . . . . . 182 156 . . SPRING, cprsn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 4
. . . 18 . . . . . . . . . . . . . . . 182 155 . . SPRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 2
. . . 19 . . . . . . . . . . . . . . . 132 746 . . BUSHING, spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 2
. . . 20 . . . . . . . . . . . . . . . 181 522 . . SHAFT, spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 21 . . . . . . . . . . . . . . . 132 747 . . CARRIER, shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 22 . . . . . . . . . . . . . . . 133 739 . . WASHER, flat buna .375 ID x .625 OD x .062thk . . . . . . . . . . . . . . 1 . . . . 1
. . . 23 . . . . . . . . . . . . . . . 183 330 . . KNOB, w/extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 24 . . . PC51 . . ♦♦198 004 . . CIRCUIT CARD, digital tach (consisting of) . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . . . . . . PLG57 . . . . . 131 204 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . . . . . . . . . . . . . . . . . . . 604 311 . . . . GROMMET, rbr .250 ID x .375mtg hole .062 groove . . . . . . . . . 1 . . . . 1
. . . . . . . . PLG58 . . . . . 131 203 . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 25 . . . . . . . . . . . . ♦♦132 611 . . OPTICAL ENCODER DISC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 26 . . . . . . . . . . . . . . . 167 387 . . SPACER, locating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2
. . . 27 . . . . . . . . . . . . . . . 168 825 . . DRIVE, pinion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 28 . . . . . . . . . . . . . . . 133 308 . . RING, retaining ext .375 shaft x .025thk . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 29 . . . . . . . . . . . . . . . 134 834 . . HOSE, SAE .187 ID x .410 OD (order by ft) . . . . . . . . . . . . . . . . . 2ft . . 2ft
. . . 30 . . . . . . . . . . . . . . . 149 959 . . FITTING, brs barbed M 3/16tbg x .312-24 . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 31 . . . . . . . . . . . . . . . 179 265 . . ADAPTER, gun/feeder LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 31 . . . . . . . . . . . . . . . 179 264 . . ADAPTER, gun/feeder RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 32 . . . . . . . . . . . . . . . 108 940 . . SCREW, cap stl hexhd .250-20 x .750 . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . 4
. . . 33 . . . . . . . . . . . . . . . 604 538 . . WASHER, flat stl SAE .312 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 34 . . . . . . . . . . . . . . . 151 437 . . KNOB, plstc T 1.125 lg x .312-18 x 1.500 . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 35 . . . . . . . . . . . . . . . 151 290 . . SCREW, mach stl hexwhd 10-32 x .500 . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2
. . . 36 . . . . . . . . . . . . . . . 179 277 . . COVER, drive roll (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . . . . . . . . . . . . . . . . . . . 178 937 . . . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 37 . . . . . . . . . . . . . . . 601 872 . . NUT, stl hex full fnsh .375-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 38 . . . . . . . . . . . . . . . 602 213 . . WASHER, lock stl split .375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 39 . . . . . . . . . . . . . . . 602 243 . . WASHER, flat stl std .375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . 40 . . . . . . . . . . . . . . . 601 966 . . SCREW, cap stl hexhd .375-16 x 1.250 . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
♦Optional High Speed Motor
*Recommended Spare Parts.
♦♦Part of Optional Tach
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-1582 Page 32
Download from Www.Somanuals.com. All Manuals Search And Download.
G u i d e
I n t e r m e d i a t e
G u i d e
I n l e t
OM-1582 Page 33
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
OM-1582 Page 34
Download from Www.Somanuals.com. All Manuals Search And Download.
Effective January 1, 2000
(Equipment with a serial number preface of “LA” or newer)
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
Warranty Questions?
LIMITED WARRANTY – Subject to the terms and conditions
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants
to its original retail purchaser that new Miller equipment sold
after the effective date of this limited warranty is free of defects
in material and workmanship at the time it is shipped by Miller.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS.
*
APT, ZIPCUT & PLAZCUT Model Plasma Cutting
Torches
Call
1-800-4-A-MILLER
for your local
Miller distributor.
*
*
*
*
*
Remote Controls
Accessory Kits
Replacement Parts (No labor)
Spoolmate 185 & Spoolmate 250
Canvas Covers
Within the warranty periods listed below, Miller will repair or
replace any warranted parts or components that fail due to
such defects in material or workmanship. Miller must be
notified in writing within thirty (30) days of such defect or
failure, at which time Miller will provide instructions on the
warranty claim procedures to be followed.
Your distributor also gives
you ...
Miller’s True Blue Limited Warranty shall not apply to:
1. Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, slip rings,
relays or parts that fail due to normal wear.
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Miller shall honor warranty claims on warranted equipment
listed below in the event of such a failure within the warranty
time periods. All warranty time periods start on the date that
the equipment was delivered to the original retail purchaser, or
one year after the equipment is sent to a North American
distributor or eighteen months after the equipment is sent to an
International distributor.
2. Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
Support
3. Equipment that has been modified by any party other
than Miller, or equipment that has been improperly
installed, improperly operated or misused based upon
industry standards, or equipment which has not had
reasonable and necessary maintenance, or equipment
which has been used for operation outside of the
specifications for the equipment.
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
1. 5 Years Parts – 3 Years Labor
*
*
Original main power rectifiers
Inverters (input and output rectifiers only)
MILLER PRODUCTS ARE INTENDED FOR PURCHASE
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND
PERSONS TRAINED AND EXPERIENCED IN THE USE
AND MAINTENANCE OF WELDING EQUIPMENT.
2. 3 Years — Parts and Labor
*
*
*
*
*
*
Transformer/Rectifier Power Sources
Plasma Arc Cutting Power Sources
Semi-Automatic and Automatic Wire Feeders
Inverter Power Supplies
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized Miller service station; or (4)
payment of or credit for the purchase price (less reasonable
depreciation based upon actual use) upon return of the goods
at customer’s risk and expense. Miller’s option of repair or
replacement will be F.O.B., Factory at Appleton, Wisconsin, or
F.O.B. at a Miller authorized service facility as determined by
Miller. Therefore no compensation or reimbursement for
transportation costs of any kind will be allowed.
Intellitig
Engine Driven Welding Generators
(NOTE: Engines are warranted separately by
the engine manufacturer.)
3. 1 Year — Parts and Labor
*
*
DS-2 Wire Feeder
Motor Driven Guns (w/exception of Spoolmate
185 & Spoolmate 250)
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR
ANY OTHER LEGAL THEORY.
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Process Controllers
Positioners and Controllers
Automatic Motion Devices
RFCS Foot Controls
Induction Heating Power Sources
Water Coolant Systems
HF Units
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN
AND ANY IMPLIED WARRANTY, GUARANTY OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
Grids
Maxstar 140
PROVISION,
MIGHT
ARISE
BY
IMPLICATION,
Spot Welders
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND
DISCLAIMED BY MILLER.
Load Banks
Miller Cyclomatic Equipment
Running Gear/Trailers
Plasma Cutting Torches (except APT & SAF
Models)
Some states in the U.S.A. do not allow limitations of how long
an implied warranty lasts, or the exclusion of incidental,
indirect, special or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty
provides specific legal rights, and other rights may be
available, but may vary from state to state.
*
Field Options
(NOTE: Field options are covered under True
Blue for the remaining warranty period of the
product they are installed in, or for a minimum of
one year — whichever is greater.)
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein,
and to the extent that they may not be waived, the limitations
and exclusions set out above may not apply. This Limited
Warranty provides specific legal rights, and other rights may
be available, but may vary from province to province.
4. 6 Months — Batteries
5. 90 Days — Parts
*
*
MIG Guns/TIG Torches
Induction Heating Coils and Blankets
miller_warr 7/00
Download from Www.Somanuals.com. All Manuals Search And Download.
Owner’s Record
Please complete and retain with your personal records.
Model Name
Purchase Date
Distributor
Address
Serial/Style Number
(Date which equipment was delivered to original customer.)
City
State
Zip
For Service
to locate a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
Replacement Parts
Training (Schools, Videos, Books)
International Headquarters–USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
European Headquarters –
United Kingdom
Phone: 44 (0) 1204-593493
FAX: 44 (0) 1204-598066
Welding Process Handbooks
Contact the Delivering Carrier for:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims,
contact your distributor and/or equipment
manufacturer’s Transportation Department.
PRINTED IN USA
2000 Miller Electric Mfg. Co. 6/00
Download from Www.Somanuals.com. All Manuals Search And Download.
|