Milan Technology Switch MIL L800i User Manual

MIL-L800i  
8-Port Power over Ethernet Injector Hub  
USER GUIDE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
1. Introduction.............................................................................................................1  
Features....................................................................................................................1  
Package Contents.....................................................................................................2  
2. Hardware Description.............................................................................................3  
Physical Dimension...................................................................................................3  
Front Panel ...............................................................................................................3  
LED Indicators...........................................................................................................4  
Rear Panel................................................................................................................4  
Power On..................................................................................................................5  
Network Application ..................................................................................................5  
3. Software Utility Installation....................................................................................7  
4. GUI Management ..................................................................................................10  
Connecting to PoE ..................................................................................................10  
System Setup & Control..........................................................................................11  
System Information .................................................................................................12  
Device Setting.........................................................................................................13  
Port Specific Control ...............................................................................................14  
Parametric Information............................................................................................17  
5. Technical Specification........................................................................................18  
6. Appendix ...............................................................................................................20  
Console Port Pin Assignments................................................................................20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.  
Introduction  
Thank you for purchasing MiLAN Technology’s EmPoweredTM Series 8-port Power over  
Ethernet Injector Hub. Power-over-Ethernet (PoE) eliminates the need to run 110/220  
VAC power to other devices on a wired LAN. Using Power-over-Ethernet, system  
installers need to run only a single CAT5 Ethernet cable that carries both power and data  
to each device. This allows greater flexibility in locating network devices and significantly  
decreases installation costs, in many cases.  
There are two system components in PoE -- the Power Sourcing Equipment (PSE)  
initiates the connection to the second component, the Powered Device (PD). The current  
is transmitted over two of the four twisted pairs of wires in a Category-5 cable.  
The MIL-L800i complies with the IEEE 802.3af standard and is completely compatible  
with existing industry standard Ethernet switches and networked devices. Since the  
Power Sourcing Equipment (PSE) tests whether a networked device is PoE-capable,  
power is never transmitted unless a Powered Device (PD) is at other end of the cable. It  
also continues to monitor the channel. If the Powered Device does not draw a minimum  
current, because it has been unplugged or physically turned off, the PSE automatically  
shuts down the power to that port. Optionally, the standard permits Powered Devices to  
signal to the PSEs exactly how much power they need.  
Features  
8 port Power over Ethernet Injector Hub  
IEEE802.3af compliance, Power over Ethernet Mid-Spain mode  
Remote power feeding up to 100 meters and for IEEE802.3 10Base-T, IEEE 802.3u  
100Base-TX standard  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Auto detect PD and classification of power consumption level  
Supports manual control of port power detection and classification  
Support automatic system calibration  
Support Auto MDI/MDI-X depends on the uplink switch port  
Centralized power distribution for PoE powered Device (PD)  
High safety short circuit protection to prevent cable short  
Supports IEEE 802.3af non-standard device, and supports manual detection of PD  
Auto refresh port status and support Plug and Play feature for PD  
Package Contents  
Unpack the contents of the package and verify them against the checklist below.  
MIL-L800i -- 8 port Power over Ethernet Hub  
Power Cord  
RS-232 cable  
User's Guide  
Software Utility CD-ROM  
Warranty Card  
If any item is missing or damaged, please contact your local dealer for service.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.  
Hardware Description  
This Section describes the hardware of the 8 port Power over Ethernet Hub, and gives a  
physical and functional overview.  
Physical Dimensions  
The MIL-L800i PoE Injector Hub’s physical dimension is:  
440mm x 224mm x 44mm (Lx W x H)  
Front Panel  
The Front Panel of the MIL-L800i PoE Injector Hub consists of 16x RJ-45 Ethernet ports  
(8xData In+8x Data+Power Out), LED indicators, and one console port.  
Figure 2-1. The Front panel of 8 port Power over Ethernet Hub  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
LED Indicators  
The LED Indicators gives real-time information of systematic operation status. The  
following table provides descriptions of LED status and their meaning.  
Figure 2-2. LED indicators  
LED  
Status  
Color  
Description  
On  
Green  
Power is transmitting to the device  
Power  
Power is not transmitting to the  
device  
Forwarding  
Off  
--  
On  
Orange  
Orange  
--  
Device is overload or short.  
It is detecting the PD.  
No device attached.  
Blinking  
Off  
Power Off  
Table 2-1. The Description of LED Indicators  
Rear Panel  
The 3-pronged power plug, 2 Ventilation fan and on/off switching are located at the rear  
panel of the 8 port Power over Ethernet Hub. The device will work with AC in the range  
100-240V AC, 50-60Hz.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 2-3 Rear panel of the 8 port Power over Ethernet Hub  
Power On  
Connect the power cord to the power socket on the rear panel of the Switch. The other  
side of power cord connects to the power outlet. The internal power supply of the Switch  
works with voltage range of AC in the 100-240VAC, frequency 50~60Hz. Check the  
power indicator on the front panel to see if power is properly supplied.  
Network Application  
The Power over Ethernet Hub can provides power to the PD that follow the IEEE 802.3af  
standard in the network. It can solve the problem of position limitation. The network  
device can be installed in more appropriate position for better performance. The  
following figure is an example of network application for Power over Ethernet Hub.  
[Note] When the Power over Ethernet Hub connects with the Cisco Aironet 350, please  
use cross over cable for connection. For the other brands’ devices, please use  
non-cross over cable.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
CoreSwitch  
7x  
1x  
8x  
2x  
9x 10x 11x 12x  
7x  
8x  
9x 10x 11x 12x  
C
A
AC power  
7
1
8
2
9101112  
3 4  
5
6
3x  
4x  
5x  
6x  
1x  
2x  
3x  
4x  
5x  
6x  
A
B
Switch  
7x  
1x  
8x  
2x  
9x 10x 11x 12x  
7x  
8x  
2x  
9x 10x 11x 12x  
C
A
AC power  
7
1
8
2
9101112  
3 4  
5
6
3x  
4x  
5x  
6x  
1x  
3x  
4x  
5x  
6x  
A
B
100M  
Power over Ethernet Hub  
AC power  
PC or  
Notebook  
Power over Ethernet Hub provide  
power to Powered device  
POWERFAULT DATA ALARM  
Powered Device, ex: SOHO  
switchor WirelessAP  
Figure 2-3 Power over Ethernet Hub network application  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.  
Software Utility Installation  
Berfore you start to remote configuring PD, please intsall the software utility. Through the  
software utility, you can easily to controll the PD that connect with PoE and view the PD  
parameter informations. The software utility provides GUI interface and user can easily  
to start with it. The software utility supports Windows environment -- Window 98, 2000,  
and XP. Please follow the below steps to install the software utility.  
1. Insert the software utility CD-ROM into your CD-ROM drive.  
2. Run the “setup.exe”.  
3. You will see the installation screen display.  
4. Then, click the “OK” button to go next step. See Figure 3-1.  
Figure 3-1  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Click the  
button to start installation. See Figure 3-2.  
Figure 3-2  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. When installation finishes, click “OK” button to finish. See Figure 3-3.  
Figure 3-3  
7. To run the software utility, go to “StarÆ ProgramÆ Power Over Ethernet  
series”.  
8. If you want to remove the software utility, go to “StarÆ Control PanelÆ  
Remove/ Add applicationÆ Power Over Ethernet series”.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.  
GUI Management  
Connecting to PoE  
Connecting the PoE with PC through the console port. Then, connect the PD (Powered  
Device) to the port of PoE. Run the software utility and select the COM port form Serial  
Link Setup function. You will see the main utility interface as figure 4-1.  
Figure 4-1. The GUI management interface  
The GUI management is divided into three parts:  
System Setup & Control: main system level parameters setup for the POE system.  
System Information: display hardware version, firmware version, and utility  
version.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Device Setting: you can save the device configuration to system, down load the  
device current configuration to the utility system and enable auto refresh function.  
Port Specific Control: each port specific function control and relate parameters  
display.  
Parametric Information: port parameters information display.  
System Setup & Control  
Calibrate System: when the system can’t do the port controlling, please remove the  
PD device and enable this function to calibrate internal system.  
PD Discovery R (ohms): set the PD resistor value range for the system detecting.  
The default value range is 19000~26500. You can adjust the upper and lower limit  
value when the system can’t detect the PD resistor in the default range. Please refer to  
the “Discover R (ohms)” value in Parametric Information section to adjust the upper  
and lower limit value. After you have adjusted the upper or lower limit value, please  
unplug and then plug in the PD device.  
Figure 4-2. System Setup & Control interface  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Information  
Chip Version: display the system chipset version and revision information.  
Firmware Version: display the system firmware version.  
Utility Version: display the system utility version  
Total Port Power (W): total of all the port power that the system provided to PD.  
Figure 4-3. System Information interface  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Device Setting  
Enable Auto-Refresh: It allows the system auto refresh the system parameters.  
The system auto refresh in every 2 seconds.  
Load from Device : To get the last configuration value from device to the system  
utility.  
Save to Device : When you have configured the System Setup & Control and  
Port Specific Control, please press Save to Device  
configuration into the system.  
button to apply the new  
Figure 4-4 Device Setting interface  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Specific Control  
Port Enable: enabling the port. This function is co-responding with “Master Enable”  
function.  
Bypass Detection: bypass the detection function. Normally the system will try to  
detect the 25kresistor in an 802.3af compliant PD device. If the PD doesn’t follow  
by IEEE 802.3af standard, you can enable this option to skip the detection on PD.  
When you enable this function, the system will not perform the 25resistor  
detection for PD and directly transmit the power to PD. This function can be  
cooperating with “PD discover R (ohms)” function in System setup & Control section  
for non-standard compliant PD device.  
[Note] after setting the Bypass Detection function, please unplug and then plug in  
the PD device.  
Bypass Classification: the system will skip the power classification and directly  
transmit the power to PD when this function is enabling. Normally the system will try  
to classify the 802.3af compliant PD device by checking the current class level. The  
following table is a standard current classification level table.  
Note: After setting the Bypass Classification function, please unplug and then plug in  
the PD device.  
Power Device  
Power (W)  
Classification Current  
(mA)  
Class  
Usage  
MIN  
MAX  
MIN  
MAX  
0
1
2
3
4
Default  
Optional  
Optional  
Optional  
Optional  
0.44  
0.44  
3.84  
6.49  
12.95  
3.84  
0
4
9
12  
20  
30  
44  
6.49  
17  
26  
36  
12.95  
Reserved for future use  
Table of Power Device Classification Levels  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LED Status Indicators: current LED indicator display – green, yellow, and red. The  
LED indicator will change depends on the PD status.  
¾
Green: It represents PD is connecting with the POE hub system and working  
normally.  
¾
¾
Yellow: It represents there is no PD connecting with the port.  
RED: It represents PD’s power request is over the system support limit or the  
cable is short.  
Fault Status: display the PD error status message. There are three error status and  
explain as following.  
¾
¾
Null: It means there is no PD connected or the connected PD device status is  
normal.  
Overload: It means the current is over the PD current classification limited  
(475mA @ 48V DC) that the situation happens over 50msec.  
Mode Status: display the PD current operation mode status.  
¾
V sample or I sample: It means " Current sample or Voltage sample”. When  
PD is detected and current is supplied, the POE hub will keep detecting and  
sampling some current or voltage to ensure whether the PD still present on this  
port. It is a IEEE 802.3af operating procedure.  
¾
R detect: When the port doesn’t connect with any PD, the POE hub will poll  
each port and detects the resistor.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 4-5. Port Specific Control interface  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parametric Information  
Discovery R (ohms): display resistance value.  
Port Current (mA): display current value.  
Port Voltage (V): display voltage value.  
Port Power (W): display watt value.  
Class Current (mA): display class current value. When you enable the “Bypass  
classification” function, the class current value will not show in here. Please refer to  
the following table for output value.  
Maximum power of levels at  
Class  
Usage  
output of PSE  
15.4 Watts  
0
1
2
3
4
Default  
Optional  
4.0 Watts  
Optional  
7.0 Watts  
Optional  
15.4 Watts  
Reserved for future use  
Treat as Class 0  
Determined Class: display power class. When you enable the “Bypass  
classification” function, the class value will not be shown.  
Figure 4-6. Parametric Information interface  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.  
Technical Specification  
IEEE802.3af Power over Ethernet  
Standards  
IEEE802.3 10Base-T,  
IEEE 802.3u 100Base-TX  
Data in: 8 x RJ-45, Data pin 1,2,3,6  
Connector  
Data and power out: 8 x RJ-45. Data pin  
1,2,3,6 Power pin (V+): 4,5, Power pin (V-): 7,8  
Per port DC 48V@350mA (Maximum), Per  
system 125Watts (maximum)  
Power out put  
Microsoft windows based application for power  
management  
Management  
Power over Ethernet mode  
Mid-Spain  
Support Microsoft windows based application  
for power management  
Management utility  
Plug and play for standard PD and without any  
software configuration  
System calibrate, IEEE 802.3af resistor range  
adjust  
System setup and control  
Port configuration control  
Port Disable / Enable  
PD detect control (enable/disable)  
Classification detect control (enable/disable)  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Null: no PD present or PD status is normal  
Overload: current support over 475mA @ DC  
48V and over 50 milliseconds  
Fault status detect  
Mode status  
System detects status – I- sample, V-sample  
and R-detect  
It will show current PD parameters which  
include Discover-resistor detected value,  
current, voltage, power consumption,  
classification current and determined class  
Parametric information  
System: power  
LED  
Per port: power Forwarding, power off  
AC 100~240V, 50/60 Hz, 130 Watts, IEC  
power socket with fuse and power switch  
Power  
Power consumption  
Cooling  
130 Watts (maximum)  
2 x DC fan  
Weight  
2.7Kg  
Operating environment  
0~45, 90%RH  
Storage temperature  
-40~70, 95% RH  
Humidity Temperature  
Dimension  
10% ~ 90% (non-condensing)  
440mm x 224mm x 44mm (L x W x H)  
EMI & Safety  
FCC Class A, CE, UL, cUL  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.  
Appendix  
Console Port Pin Assignments  
The female DB-9 serial port on the POE hub front panel is used to connect to the switch  
for out-of-band console configuration. The web interface configuration program can be  
accessed from PC running the system utility program. The pin assignments used to  
connect to the serial port are provided in the following tables.  
Figure 6-1. DB-9 Console Port Pin Numbers  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DB-9 Port Pin Assignments  
Switch’s DB9 PC DB9  
EIA Circuit  
CCITT Signal Description  
DTE Pin #  
DTE Pin #  
RxD (Received  
Data)  
BB  
104  
103  
102  
2
2
TxD  
BA  
AB  
(Transmitted  
Data)  
3
5
3
5
SGND (Signal  
Ground)  
NOTE: Remaining pins are not used.  
Console Port to 9-Pin DTE Port on PC  
Switch’s 9-Pin Serial  
CCITT Signal PC’s 9-Pin  
DTE Port  
Port  
2 RXD  
3 TXD  
<---------RXD ------------  
-----------TXD ---------->  
-----------SGND ----------  
3 TxD  
2 RxD  
5 SGND  
5 SGND  
NOTE: Remaining pins are not used.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
90000429 Rev 1P  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Milan Technology Switch CERTXFX01 User Manual
MTD Lawn Mower 111 020 300 User Manual
Nikon Camera Accessories EL4 User Manual
Olympus Computer Drive MAUSB 200 User Manual
Onkyo CD Player DX 7555 User Manual
OPPO Digital Blu ray Player BDP 80 User Manual
Palsonic CRT Television 5159P User Manual
Panasonic Air Conditioner CS MKS18NKU User Manual
Panasonic Blu ray Player DMP BDT300 User Manual
Panasonic Digital Camera DMC F1A User Manual