MIL-L800i
8-Port Power over Ethernet Injector Hub
USER GUIDE
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
1. Introduction.............................................................................................................1
Features....................................................................................................................1
Package Contents.....................................................................................................2
2. Hardware Description.............................................................................................3
Physical Dimension...................................................................................................3
Front Panel ...............................................................................................................3
LED Indicators...........................................................................................................4
Rear Panel................................................................................................................4
Power On..................................................................................................................5
Network Application ..................................................................................................5
3. Software Utility Installation....................................................................................7
4. GUI Management ..................................................................................................10
Connecting to PoE ..................................................................................................10
System Setup & Control..........................................................................................11
System Information .................................................................................................12
Device Setting.........................................................................................................13
Port Specific Control ...............................................................................................14
Parametric Information............................................................................................17
5. Technical Specification........................................................................................18
6. Appendix ...............................................................................................................20
Console Port Pin Assignments................................................................................20
Download from Www.Somanuals.com. All Manuals Search And Download.
1.
Introduction
Thank you for purchasing MiLAN Technology’s EmPoweredTM Series 8-port Power over
Ethernet Injector Hub. Power-over-Ethernet (PoE) eliminates the need to run 110/220
VAC power to other devices on a wired LAN. Using Power-over-Ethernet, system
installers need to run only a single CAT5 Ethernet cable that carries both power and data
to each device. This allows greater flexibility in locating network devices and significantly
decreases installation costs, in many cases.
There are two system components in PoE -- the Power Sourcing Equipment (PSE)
initiates the connection to the second component, the Powered Device (PD). The current
is transmitted over two of the four twisted pairs of wires in a Category-5 cable.
The MIL-L800i complies with the IEEE 802.3af standard and is completely compatible
with existing industry standard Ethernet switches and networked devices. Since the
Power Sourcing Equipment (PSE) tests whether a networked device is PoE-capable,
power is never transmitted unless a Powered Device (PD) is at other end of the cable. It
also continues to monitor the channel. If the Powered Device does not draw a minimum
current, because it has been unplugged or physically turned off, the PSE automatically
shuts down the power to that port. Optionally, the standard permits Powered Devices to
signal to the PSEs exactly how much power they need.
Features
8 port Power over Ethernet Injector Hub
IEEE802.3af compliance, Power over Ethernet Mid-Spain mode
Remote power feeding up to 100 meters and for IEEE802.3 10Base-T, IEEE 802.3u
100Base-TX standard
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Auto detect PD and classification of power consumption level
Supports manual control of port power detection and classification
Support automatic system calibration
Support Auto MDI/MDI-X depends on the uplink switch port
Centralized power distribution for PoE powered Device (PD)
High safety short circuit protection to prevent cable short
Supports IEEE 802.3af non-standard device, and supports manual detection of PD
Auto refresh port status and support Plug and Play feature for PD
Package Contents
Unpack the contents of the package and verify them against the checklist below.
MIL-L800i -- 8 port Power over Ethernet Hub
Power Cord
RS-232 cable
User's Guide
Software Utility CD-ROM
Warranty Card
If any item is missing or damaged, please contact your local dealer for service.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
2.
Hardware Description
This Section describes the hardware of the 8 port Power over Ethernet Hub, and gives a
physical and functional overview.
Physical Dimensions
The MIL-L800i PoE Injector Hub’s physical dimension is:
440mm x 224mm x 44mm (Lx W x H)
Front Panel
The Front Panel of the MIL-L800i PoE Injector Hub consists of 16x RJ-45 Ethernet ports
(8xData In+8x Data+Power Out), LED indicators, and one console port.
Figure 2-1. The Front panel of 8 port Power over Ethernet Hub
3
Download from Www.Somanuals.com. All Manuals Search And Download.
LED Indicators
The LED Indicators gives real-time information of systematic operation status. The
following table provides descriptions of LED status and their meaning.
Figure 2-2. LED indicators
LED
Status
Color
Description
On
Green
Power is transmitting to the device
Power
Power is not transmitting to the
device
Forwarding
Off
--
On
Orange
Orange
--
Device is overload or short.
It is detecting the PD.
No device attached.
Blinking
Off
Power Off
Table 2-1. The Description of LED Indicators
Rear Panel
The 3-pronged power plug, 2 Ventilation fan and on/off switching are located at the rear
panel of the 8 port Power over Ethernet Hub. The device will work with AC in the range
100-240V AC, 50-60Hz.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2-3 Rear panel of the 8 port Power over Ethernet Hub
Power On
Connect the power cord to the power socket on the rear panel of the Switch. The other
side of power cord connects to the power outlet. The internal power supply of the Switch
works with voltage range of AC in the 100-240VAC, frequency 50~60Hz. Check the
power indicator on the front panel to see if power is properly supplied.
Network Application
The Power over Ethernet Hub can provides power to the PD that follow the IEEE 802.3af
standard in the network. It can solve the problem of position limitation. The network
device can be installed in more appropriate position for better performance. The
following figure is an example of network application for Power over Ethernet Hub.
[Note] When the Power over Ethernet Hub connects with the Cisco Aironet 350, please
use cross over cable for connection. For the other brands’ devices, please use
non-cross over cable.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
CoreSwitch
7x
1x
8x
2x
9x 10x 11x 12x
7x
8x
9x 10x 11x 12x
C
A
AC power
7
1
8
2
9101112
3 4
5
6
3x
4x
5x
6x
1x
2x
3x
4x
5x
6x
A
B
Switch
7x
1x
8x
2x
9x 10x 11x 12x
7x
8x
2x
9x 10x 11x 12x
C
A
AC power
7
1
8
2
9101112
3 4
5
6
3x
4x
5x
6x
1x
3x
4x
5x
6x
A
B
100M
Power over Ethernet Hub
AC power
PC or
Notebook
Power over Ethernet Hub provide
power to Powered device
POWERFAULT DATA ALARM
Powered Device, ex: SOHO
switchor WirelessAP
Figure 2-3 Power over Ethernet Hub network application
6
Download from Www.Somanuals.com. All Manuals Search And Download.
3.
Software Utility Installation
Berfore you start to remote configuring PD, please intsall the software utility. Through the
software utility, you can easily to controll the PD that connect with PoE and view the PD
parameter informations. The software utility provides GUI interface and user can easily
to start with it. The software utility supports Windows environment -- Window 98, 2000,
and XP. Please follow the below steps to install the software utility.
1. Insert the software utility CD-ROM into your CD-ROM drive.
2. Run the “setup.exe”.
3. You will see the installation screen display.
4. Then, click the “OK” button to go next step. See Figure 3-1.
Figure 3-1
7
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Click the
button to start installation. See Figure 3-2.
Figure 3-2
8
Download from Www.Somanuals.com. All Manuals Search And Download.
6. When installation finishes, click “OK” button to finish. See Figure 3-3.
Figure 3-3
7. To run the software utility, go to “Star” Æ “Program” Æ “Power Over Ethernet
series”.
8. If you want to remove the software utility, go to “Star” Æ “Control Panel” Æ
“Remove/ Add application” Æ “Power Over Ethernet series”.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
4.
GUI Management
Connecting to PoE
Connecting the PoE with PC through the console port. Then, connect the PD (Powered
Device) to the port of PoE. Run the software utility and select the COM port form Serial
Link Setup function. You will see the main utility interface as figure 4-1.
Figure 4-1. The GUI management interface
The GUI management is divided into three parts:
System Setup & Control: main system level parameters setup for the POE system.
System Information: display hardware version, firmware version, and utility
version.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Device Setting: you can save the device configuration to system, down load the
device current configuration to the utility system and enable auto refresh function.
Port Specific Control: each port specific function control and relate parameters
display.
Parametric Information: port parameters information display.
System Setup & Control
Calibrate System: when the system can’t do the port controlling, please remove the
PD device and enable this function to calibrate internal system.
PD Discovery R (ohms): set the PD resistor value range for the system detecting.
The default value range is 19000~26500. You can adjust the upper and lower limit
value when the system can’t detect the PD resistor in the default range. Please refer to
the “Discover R (ohms)” value in Parametric Information section to adjust the upper
and lower limit value. After you have adjusted the upper or lower limit value, please
unplug and then plug in the PD device.
Figure 4-2. System Setup & Control interface
11
Download from Www.Somanuals.com. All Manuals Search And Download.
System Information
Chip Version: display the system chipset version and revision information.
Firmware Version: display the system firmware version.
Utility Version: display the system utility version
Total Port Power (W): total of all the port power that the system provided to PD.
Figure 4-3. System Information interface
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Device Setting
Enable Auto-Refresh: It allows the system auto refresh the system parameters.
The system auto refresh in every 2 seconds.
Load from Device : To get the last configuration value from device to the system
utility.
Save to Device : When you have configured the System Setup & Control and
Port Specific Control, please press Save to Device
configuration into the system.
button to apply the new
Figure 4-4 Device Setting interface
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Specific Control
Port Enable: enabling the port. This function is co-responding with “Master Enable”
function.
Bypass Detection: bypass the detection function. Normally the system will try to
detect the 25kΩ resistor in an 802.3af compliant PD device. If the PD doesn’t follow
by IEEE 802.3af standard, you can enable this option to skip the detection on PD.
When you enable this function, the system will not perform the 25Ω resistor
detection for PD and directly transmit the power to PD. This function can be
cooperating with “PD discover R (ohms)” function in System setup & Control section
for non-standard compliant PD device.
[Note] after setting the Bypass Detection function, please unplug and then plug in
the PD device.
Bypass Classification: the system will skip the power classification and directly
transmit the power to PD when this function is enabling. Normally the system will try
to classify the 802.3af compliant PD device by checking the current class level. The
following table is a standard current classification level table.
Note: After setting the Bypass Classification function, please unplug and then plug in
the PD device.
Power Device
Power (W)
Classification Current
(mA)
Class
Usage
MIN
MAX
MIN
MAX
0
1
2
3
4
Default
Optional
Optional
Optional
Optional
0.44
0.44
3.84
6.49
12.95
3.84
0
4
9
12
20
30
44
6.49
17
26
36
12.95
Reserved for future use
Table of Power Device Classification Levels
14
Download from Www.Somanuals.com. All Manuals Search And Download.
LED Status Indicators: current LED indicator display – green, yellow, and red. The
LED indicator will change depends on the PD status.
¾
Green: It represents PD is connecting with the POE hub system and working
normally.
¾
¾
Yellow: It represents there is no PD connecting with the port.
RED: It represents PD’s power request is over the system support limit or the
cable is short.
Fault Status: display the PD error status message. There are three error status and
explain as following.
¾
¾
Null: It means there is no PD connected or the connected PD device status is
normal.
Overload: It means the current is over the PD current classification limited
(475mA @ 48V DC) that the situation happens over 50msec.
Mode Status: display the PD current operation mode status.
¾
V sample or I sample: It means " Current sample or Voltage sample”. When
PD is detected and current is supplied, the POE hub will keep detecting and
sampling some current or voltage to ensure whether the PD still present on this
port. It is a IEEE 802.3af operating procedure.
¾
R detect: When the port doesn’t connect with any PD, the POE hub will poll
each port and detects the resistor.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 4-5. Port Specific Control interface
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Parametric Information
Discovery R (ohms): display resistance value.
Port Current (mA): display current value.
Port Voltage (V): display voltage value.
Port Power (W): display watt value.
Class Current (mA): display class current value. When you enable the “Bypass
classification” function, the class current value will not show in here. Please refer to
the following table for output value.
Maximum power of levels at
Class
Usage
output of PSE
15.4 Watts
0
1
2
3
4
Default
Optional
4.0 Watts
Optional
7.0 Watts
Optional
15.4 Watts
Reserved for future use
Treat as Class 0
Determined Class: display power class. When you enable the “Bypass
classification” function, the class value will not be shown.
Figure 4-6. Parametric Information interface
17
Download from Www.Somanuals.com. All Manuals Search And Download.
5.
Technical Specification
IEEE802.3af Power over Ethernet
Standards
IEEE802.3 10Base-T,
IEEE 802.3u 100Base-TX
Data in: 8 x RJ-45, Data pin 1,2,3,6
Connector
Data and power out: 8 x RJ-45. Data pin
1,2,3,6 Power pin (V+): 4,5, Power pin (V-): 7,8
Per port DC 48V@350mA (Maximum), Per
system 125Watts (maximum)
Power out put
Microsoft windows based application for power
management
Management
Power over Ethernet mode
Mid-Spain
Support Microsoft windows based application
for power management
Management utility
Plug and play for standard PD and without any
software configuration
System calibrate, IEEE 802.3af resistor range
adjust
System setup and control
Port configuration control
Port Disable / Enable
PD detect control (enable/disable)
Classification detect control (enable/disable)
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Null: no PD present or PD status is normal
Overload: current support over 475mA @ DC
48V and over 50 milliseconds
Fault status detect
Mode status
System detects status – I- sample, V-sample
and R-detect
It will show current PD parameters which
include Discover-resistor detected value,
current, voltage, power consumption,
classification current and determined class
Parametric information
System: power
LED
Per port: power Forwarding, power off
AC 100~240V, 50/60 Hz, 130 Watts, IEC
power socket with fuse and power switch
Power
Power consumption
Cooling
130 Watts (maximum)
2 x DC fan
Weight
2.7Kg
Operating environment
0℃~45℃, 90%RH
Storage temperature
-40℃~70℃, 95% RH
Humidity Temperature
Dimension
10% ~ 90% (non-condensing)
440mm x 224mm x 44mm (L x W x H)
EMI & Safety
FCC Class A, CE, UL, cUL
19
Download from Www.Somanuals.com. All Manuals Search And Download.
6.
Appendix
Console Port Pin Assignments
The female DB-9 serial port on the POE hub front panel is used to connect to the switch
for out-of-band console configuration. The web interface configuration program can be
accessed from PC running the system utility program. The pin assignments used to
connect to the serial port are provided in the following tables.
Figure 6-1. DB-9 Console Port Pin Numbers
20
Download from Www.Somanuals.com. All Manuals Search And Download.
DB-9 Port Pin Assignments
Switch’s DB9 PC DB9
EIA Circuit
CCITT Signal Description
DTE Pin #
DTE Pin #
RxD (Received
Data)
BB
104
103
102
2
2
TxD
BA
AB
(Transmitted
Data)
3
5
3
5
SGND (Signal
Ground)
NOTE: Remaining pins are not used.
Console Port to 9-Pin DTE Port on PC
Switch’s 9-Pin Serial
CCITT Signal PC’s 9-Pin
DTE Port
Port
2 RXD
3 TXD
<---------RXD ------------
-----------TXD ---------->
-----------SGND ----------
3 TxD
2 RxD
5 SGND
5 SGND
NOTE: Remaining pins are not used.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
90000429 Rev 1P
Download from Www.Somanuals.com. All Manuals Search And Download.
|