USER’S GUIDE
NDM-FTX-xxxxx-01
NDM-FTX-xxxxx-01 (standard)
NDM-FTX-xxxxx-01(L) (low profile)
Fast Ethernet Fiber/Dual Media NICs
•
•
•
Fast Ethernet
Copper and Fiber
10/100Base-TX and/or 100Base-FX
Transition Networks NDM-FTX series
fast Ethernet dual media NIC (Network
Interface Card) provides a 10/100Base-
TX copper port and a 100Base-FX fiber
port for installation flexibility in a
mixed-media environment. The dual
ports can also provide redundancy for
critical applications. These NICs come in standard and low profile form factors, and
include driver support for a variety of operating systems.
Part Number
Port One - Copper Port Two - Duplex Fiber-Optic
10/100Base-TX
100Base-FX
RJ-45
100 m (328 ft)*
ST, 1300 nm multimode
2 km (1.2 miles)*
NDM-FTX-ST-01
NDM-FTX-ST-01(L)
RJ-45
100 m (328 ft)*
SC, 1300 nm multimode
2 km (1.2 miles)*
NDM-FTX-SC-01
NDM-FTX-SC-01(L)
RJ-45
100 m (328 ft)*
MT-RJ, 1300 nm multimode
2 km (1.2 miles)*
NDM-FTX-MT-01
NDM-FTX-MT-01(L)
RJ-45
100 m (328 ft)*
SC, 1310 nm single mode
5 km (3.1miles)*
NDM-FTX-SC5-01
NDM-FTX-SC5-01(L)
RJ-45
100 m (328 ft)*
SC, 1310 nm single mode
20 km (12.4 miles)*
NDM-FTX-SC20-01
NDM-FTX-SC20-01(L)
RJ-45
100 m (328 ft)*
SC, 1310 TX/1550nm RX single
mode, single fiber 20 km (12.4 miles)*
NDM-FTX-SB201-01
NDM-FTX-SB201-01(L)
RJ-45
100 m (328 ft)*
SC, 1550 TX/1310 nm RX single
mode, single fiber 20 km (12.4 miles)*
NDM-FTX-SB202-01
NDM-FTX-SB202-01(L)
Optional accessories sold separately
Part Number
BTR-NDM-RPL
BTR-NDM-PXE
Description
RPL, Bootable ROM Chip
PXE, Bootable ROM Chip
*Typical maximum cable distance.
Actual distance is dependent upon the
physical characteristics of the network
installation.
Installation . . . . . . . . . . . . . . . . . . .2
Cable Specifications . . . . . . . . . . .4
Technical Specifications . . . . . . . .5
Troubleshooting . . . . . . . . . . . . . . .6
Contact Us . . . . . . . . . . . . . . . . . . .7
Download from Www.Somanuals.com. All Manuals Search And Download.
NDM-FTX Series Fast Ethernet Dual Media NIC
Fiber cable -- continued
Cable Specifications
Copper cable
NDM-FTX-SB202-01(x)
1550 TX/1310 RX nm single mode
single stand
10BASE-T UTP Category 3, 4, 5 or higher
100Base-TX UTP Category 5 or higher
Fiber optic transmitter power:
Fiber optic receiver sensitivity:
Link budget:
min: -14.0 dBm
min: -32.0 dBm
18.0 dB
max: -8.0 dBm
max: 0.0 dBm
Gauge:
24 to 22AWG
Attenuation:
22.0 dB /100m @ 100 MHz
The fiber optic transmitters on the device meet Class I Laser safety requirements per IEC-
825/CDRH standard and comply with 21CRF1040.10 and 21CRF1040.11.
•
•
•
•
•
Straight-through MDI twisted-pair cable must be used.
Shielded STP or unshielded UTP twisted-pair cable may be used.
Pins 1 and 2, 3 and 6 are the two active pairs in an Ethernet network.
RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
Use only dedicated wire pairs for the active pins:
Technical Specifications
For models NDM-FTX-xxxxx-01 and NDM-FTX-xxxxx-01(L)
(e.g., blue/white and white/blue, orange/white and white/orange, etc.)
DO NOT use flat or silver satin wire.
Standards:
Expansion bus standard:
Data rate:
IEEE 802.3
PCI 2.1, 2.2
10/100Mpbs twisted pair media
100Mbps fiber media
LINK/ACT (on the bracket)
ON = communication link; flashing = activity on link
FDX (full duplex link); ON = full duplex link
• NetWare Server 4.1x, 5.x
• Netware DOS Client ODI
• Windows 95, 98, 2000, 2003, XP, NT4.0
• Linux
Novell RPL Boot ROM; PXE Boot ROM
2.5” W x 5.9” D x 0.85” H
(63.5 mm W x 149.9 mm D x 21.6 mm H)
3 oz. (91g) approximate
1.0A @ +5VDC
198,853 hours (Bellcore7 V5.0)
0°C to 50°C (32°F to 122°F)
-25°C to 85°C (-13°F to 185°F)
5% to 90%, non-condensing
0 to 10,000 feet
•
Straight-Through Cable
1
2
1
2
Twisted Pair #1
Twisted Pair #2
LED:
3
6
3
6
Drivers:
The physical characteristics must meet or exceed the IEEE 802.3 specification.
Fiber cable
Bit error rate:
<10-9
Boot server support:
PCB dimensions:
Single mode fiber (recommended):
Multimode fiber (recommended):
Multimode fiber (optional):
9 µm
62.5/125 µm
100/140, 85/140, 50/125 µm
Weight:
Power consumption:
MTBF
Operating temp
Storage temp:
Humidity:
NDM-FTX-ST-01(x), NDM-FTX-SC-01(x), NDM-FTX-MT-01(x) 1300 nm multimode
Fiber optic transmitter power:
Fiber optic receiver sensitivity:
Link budget:
min: -19.0 dBm
min: -31.0 dBm
12.0 dB
max: -14.0 dBm
max: -17.0 dBm
NDM-FTX-SC5-01(x)
Fiber optic transmitter power:
Fiber optic receiver sensitivity:
Link budget:
1310 nm single mode
max: -14.0 dBm
max: -7.5 dBm
min: -19.0 dBm
min: -31.0 dBm
12.0 dB
Altitude:
Warranty:
Lifetime
NDM-FTX-SC20-01(x)
Fiber optic transmitter power:
Fiber optic receiver sensitivity:
Link budget:
1310 nm single mode
max: -8.0 dBm
min: -15.0 dBm
min: -31.0 dBm
16.0 dB
WARNING: Visible and invisible laser radiation when open: DO NOT stare into
the beam or view directly with optical instruments. Failure to observe this warning
could result in damage to your vision or blindness.
max: 0.0 dBm
NDM-FTX-SB201-01(x)
1310 TX/1550 RX nm single mode
single stand
CAUTION: Use of controls, adjustments, or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.
Fiber optic transmitter power:
Fiber optic receiver sensitivity:
Link budget:
min: -14.0 dBm
min: -32.0 dBm
18.0 dB
max: -8.0 dBm
max: 0.0 dBm
The information in this manual is subject to change without further notice.
5
4
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours
[email protected] -- Click the “Transition Now” link for live Web chat.
Download from Www.Somanuals.com. All Manuals Search And Download.
NDM-FTX Series Fast Ethernet Dual Media NIC
Troubleshooting
Diagnostics LEDs and Boot ROM
Contact Us
Technical support
Technical support is available at [email protected]
LEDS
• US and Canada:
• International:
1-800-260-1312 (24 hours)
The LINK/ACT LED lights when a fiber cable or twisted pair cable connection
is good. It blinks to indicate activity.
00-1-952-941-7600 (24 hours)
Transition now
The collision and full-duplex LED report board operating status.
Chat live via the Web with Transition Networks Technical Support. Log onto
Boot ROM
Web-based seminar
Transition networks provides seminars via live, web-based training. Log onto
To add the remote boot feature to a workstation, insert the Boot ROM into the
ROM socket. See Figure 1 on page 2.
After power UP, the LINK/ACT LED should light; if not, check the following:
Email
1
Confirm that the NDM-FTX module is properly inserted into the PC
workstation master slot or file-server master slot.
Ask a question anytime by sending an email to our technical support staff:
2
Confirm that the PC workstation or the file server is properly connected to
a power source and with the power source turned ON.
Address
Transition Networks
3
4
Check the fiber cable and twisted-pair copper cables for proper connection.
6475 City West Parkway
Minneapolis, MN 55344, U.S.A.
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600 if those
steps fail to produce the desired result.
Telephone:
Toll free:
Fax:
952-941-7600,
800-526-9267
952-941-2322
Note: To connect this device to a router, bridge, or switch, please refer to the
corresponding technical manual for the device.
Declaration of Conformity
Name of Mfg:
Model:
Transition Networks, 6475 City West Parkway,
Minneapolis, MN 55344 U.S.A.
NDM-FTX-xxxxx-0l and NDM-FTX-xxxxx-0l(L) Network Interface
Cards
Part Number:
NDM-FTX-ST-01(x), NDM-FTX-SC-01(x), NDM-FTX-MT-01(x),
NDM-FTX-SC5-01(x), NDM-FTX-SC20-01(x),
NDM-FTX-SB201-01(x), NDM-FTX-SB202-01(x)
Regulation:
Purpose:
EMC Directive 89/336/EEC
To declare that the NDM-FTX-xxxxx-01 and NDM-FTX-xxxxx-0l(L), to
which this declaration refers, is in conformity with the following
standards:
CISPR 22:1997+A1:2000; EN 55022:1998+A1:2000 Class A; FCC Part 15 Subpart B; 21CFR
subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and
Standard(s).
June 30, 2005
Stephen Anderson, Vice-President of Engineering
Date
7
6
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours
[email protected] -- Click the “Transition Now” link for live Web chat.
Download from Www.Somanuals.com. All Manuals Search And Download.
Compliance Information
CISPR22/EN55022 Class A, CE Mark, CISPR22/EN55022 Class A + EN55024, CE Mark
FCC regulations
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference, in which
case the user will be required to correct the interference at the user's own expense.
Canadian regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out
on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables
aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage
radioélectrique édicté par le ministère des Communications du Canada.
European regulations
Caution: This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei
Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für
Gegenmaßnahmen verantwortlich.
Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de
créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures
spécifiques appropriées.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer
Konformität.
Trademark notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright restrictions
© 2004-2005 Transition Networks. All rights reserved. No part of this work may be reproduced or
used in any form or by any means—graphic, electronic or mechanical—without written permission
from Transition Networks
Printed in the US
Manual Part Number and Rev.
33332.A
Download from Www.Somanuals.com. All Manuals Search And Download.
|