MURO Power Screwdriver VL71 FLR User Manual

Heavy Duty Auto Feeding Screwdriving Tool  
Instruction manual  
(with warranty card)  
Table of contents  
Safety precautions  
Parts designation  
Specifications  
1
1
1
Assembling VISLIDER  
Loading VISROPE  
Driving screws  
2
3 - 5  
5 - 6  
7
Maintenance and inspection  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Assembling VISLIDER  
1. Assembly and fitting of rod handle  
Remove the hexagon fitting bolt and the washer  
from the handle rod. To the handle rod, fit the  
handle bar, the washer and the hexagon bolt in this  
order. Tighten the hexagon fitting bolt using the  
13mm spanner.  
Mount the assembled rod handle on the rear of the  
main body. Tighten the two fitting screws using  
the 6mm wrench.  
2. Fitting and removal of magazine  
To fit the magazine, insert the magazine holder  
into the bracket at top end of the main body until  
it clicks.  
To remove the magazine, withdraw it while pulling  
the magazine stopper with fingers.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Loading VISROPE  
1.Setting VISROPE  
Open the magazine cover while pulling the  
magazine lever.  
Set the VISROPE to the magazine as shown  
below. (Remove the rubber band from the  
VISROPE.)  
2. Switching magazine inner lid  
Lift the inner lid while holding the inner lid stopper on the magazine cover. Insert the inner lid until it snaps in the  
orientation corresponding to the screw length.  
3. VISROPE types and stopper block adjustment  
Two types are available in the VISROPE for VL71-FLR, 30mm type and 22mm type. Depending on the type, the  
position of the guide differs and the stopper block needs to be adjusted to fit for the screws used.  
* The first VISROPE has an extended plastic strip as shown below, which is needed to drive the first screw.  
Please confirm the presence of this extension when loading.  
* The stopper block fixing cap screw, when loosened too much, can cause its head to protrude. Pay due attention  
to it.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
* Factory setting is for 30mm type.  
4. Screw guide position adjustment  
Carry out the screw guide position adjustment according to the length of the screws used.  
* Factory setting is for 45mm screw length.  
5. Feeding screws  
Insert the VISROPE into the feeder block until it stops. Push the main body by no less than 30mm, and then pull  
it back.  
When the screw is not fed to the center even after the above step was repeated several times, carry out the guide  
cover adjustment by referring to 6. Adjustment of guide cover and then retry the screw feeding.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Adjustment of guide cover  
Improper guide cover play can affect screw feeding or screw driving. Any time the VISROPE was replaced,  
make sure to check the guide cover play and adjust it to the adequate level.  
To adjust the play, first loosen the hexagon nut using the 7mm spanner and then adjust the cap screw using the  
3mm wrench. After this, tighten the hexagon nut using the 7mm spanner to fix the cap screw.  
Driving screws  
1. Adjustment of rod handle length  
2. Adjustment of screw driving depth  
To adjust the rod handle length, loosen the knob  
and press it with force to disengage the inside  
fixing tab. After this, adjust the length and  
tighten the knob to fix.  
Turn the dial to adjust the screw driving depth.  
3. Direction of bit rotation  
Direction of bit rotation can be reversed using the motor forward/reverse rotation switch. Use the forward  
(clockwise) rotation to drive (tighten) the screw, and the reverse (counterclockwise) rotation to loosen (remove) the  
screw.  
Refer to the relative instruction manual of the motor on how to operate the forward/reverse rotation switch.  
4. Driving screws  
First, depress the lock button while pulling the trigger of the motor in order to keep the motor running. Next, hold  
the handle bar of VL71-FLR and press the tool against the material at the right angle to drive the screw. When  
the screw has been driven completely to the preset depth, the clutch sound can be heard. Then, reduce the  
pressing force and pull back the handle bar. The screw driving is now finished and the next screw is made ready  
at the same time.  
* When the screw driving is finished, the sound and vibrations due to clutch contact will be produced. Go on  
using the tool if there is no problem in screw driving.  
* After performing several dozens of VISROPE driving, an empty plastic strip comes out long. Although the  
machine is usable even if this strip is untreated, cut it with a nipper at a suitable interval lest it should be entangled  
with the screws outside the magazine and should disturb the operation.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Removal of VISROPE  
To remove the VISROPE, pull out the VISROPE while the guide cover and the grip finger are open.  
* Push the main body 5mm or so to facilitate withdrawal of the VISROPE.  
6. Bit replacement  
To remove the bit, first pick up the bit as much as possible while pulling the sleeve. Then, while pulling back  
(pressing down) the top end, pull out the whole bit.  
To mount the bit, insert the bit while pulling back (pressing down) the top end. Then, while pulling the sleeve,  
insert the bit fully to its position and fix it by returning the sleeve. After this, make sure that the bit is fixed  
completely at its position by moving it up and down.  
* The bit is consumable. Worn-out bit may cause poor tightening or damage the screw head. Replace the bit  
with a new one before it is worn out.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance and inspection  
1. The tool may malfunction if it is used continuously without removing the adhered sawdust, plasterboard particles, iron  
powder or dusts. Be sure to clean the tool after every use.  
2. To wipe the unit clean, use dry cloth or neutral detergent-soaked cloth. Do not use gasoline, thinner or the like, which would  
damage the unit. Never wash the unit in water, which would get it rusty or malfunctioning.  
3. The bit of the specific adaptor kit is consumable. If its both heads have worn out, immediately replace it with new one.  
Worn-out bit may cause poor tightening or damage the screw head.  
4. Store the unit in a dry, cool place. Keep it without reach of children. Avoid any unstable spot to store the unit on.  
5. Do not disassemble and repair the unit yourself. For repairs, contact your dealer.  
VL71-FLR Warranty Card  
Model  
Date of purchase  
Names  
VL71-FLR  
Warranty period  
6 month after date of purchase  
Address  
Phone  
Address  
Name  
Phone  
Make sure that the above form is filled out. This warranty shall be invalid if the *-marked information is missing.  
1.If within the warranty period the unit fails due to defect in material or workmanship, the manufacturer will repair the unit free  
of charge.  
2.To ask for free repair within the warranty period, please take the unit and this warranty card with you to your dealer.  
3.Even within the warranty period, the following cases are not covered by this warranty.  
a) Troubles or damages due to wrong handling and use or through tampering with the unit.  
b) Troubles or damages due to dropping or rough handling during moving or transport.  
c) Troubles or damages due to fire, earthquake, flood, lightning, and other natural disasters and pollution.  
d) Troubles or damages due to poor storage and negligence in maintenance.  
e) Loss or missing of this warranty card.  
f) No date of purchase, customer's names and address, or dealer's name and address entered in this warranty card. Or  
forged document.  
4.If you want an engineer sent to you for repairing this product, you will be charged for his or her travel expenses and labor.  
5.This warranty card will never be reissued. Keep it in a safe place.  
This warranty covers free repairs within the written warranty period and under the condition of proper use. This card is not  
intended to restrict the user's legal rights. For repairs after the warranty period, contact your dealer or the Customers'  
Services of MURO NORTH AMERICA INC. or MURO CORPORATION.  
Manufacturer  
Please ask to…  
1-4-10 Kaminoge, Setagaya-ku, Tokyo, JAPAN 158-0093  
7 Tilbury Crt, Brampton, Ontario, CANADA L6T 3T4  
TEL: +81-03-3703-4122  
FAX: +81-03-3704-2348  
TEL: (905) 451-7667  
FAX: (905) 451-7936  
VL71M01U – 2002. 9. 9  
Printed in Japan  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Cooktop 6203 User Manual
NEC Flat Panel Television LCD4020 TMX4 User Manual
NEC Laptop M380 User Manual
Nikon Digital Camera SB2F01 11 User Manual
NuTone Fan QTXN110HL User Manual
Omnimount TV Video Accessories Prism 50 User Manual
Oregon Scientific Clock AS 316NE User Manual
Panamax Surge Protector PM8 EX User Manual
Panasonic Network Card DM0706SY0 User Manual
Panasonic Speaker System DVD K29GCS User Manual